40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 134 of 344  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  10684   Fri Nov 7 10:29:56 2014 SteveUpdateGeneralHe/Ne telescope

    

       
            
  
  10702   Wed Nov 12 15:14:09 2014 manasaUpdateGeneralX end AUX laser fiber setup I looked at the endtable for possible
space to setup optics in order to couple
the X end laser into a PM fiber.
 ETMXtable.png 
  10730   Fri Nov 21 11:41:24 2014 manasaUpdateGeneralX end fiber insulated and on cable tray

    

       
            
  
  10739   Mon Dec 1 15:41:38 2014 SteveUpdateGeneralX end fiber insulated and on cable tray


   
        
            
  
  10740   Mon Dec 1 16:34:20 2014 JenneUpdateGeneralIFO wake-up 
 After its' several days of
rest, it is time to wake up the IFO. 
  
  10742   Mon Dec 1 17:19:22 2014 JenneUpdateGeneralPMC align[Diego, Jenne]
Tweaked up the input alignment to
the PMC.  Now we're at 0.785.
  
  10758   Fri Dec 5 02:44:43 2014 JenneUpdateGeneralIFO alignment shenanigans[Jenne, Q, Diego]
OMG, today sucked alignment-wise. 
Like, wow. 
  
  10760   Sun Dec 7 13:11:57 2014 manasaSummaryGeneralFrequency Offset Locking - To Do ListAttached is the timeline for Frequency
Offset Locking related activities. All activities
will be done mostly in morning and early
 FOLtodolist.pdf 
  10765   Mon Dec 8 15:54:39 2014 manasaSummaryGeneralDec 8 - Check Frequency Counter module

    

       
            
  
  10766   Mon Dec 8 20:53:51 2014 diegoSummaryGeneralDec 8 - Check Frequency Counter module

    

       
            
  
  10767   Tue Dec 9 00:30:27 2014 manasaSummaryGeneralDec 9 - Elaborate to do list

    

       
            
 FOL_FiberChassis.pdf 
  10770   Tue Dec 9 16:06:46 2014 diegoSummaryGeneralDec 8 - Check Frequency Counter module

    

       
            
  
  10771   Tue Dec 9 16:07:16 2014 manasaSummaryGeneralDec 9 - FC module and fiber chassis

    

       
            
 FCmodule.png 
  10775   Wed Dec 10 16:12:29 2014 manasaSummaryGeneralDec 10 - PSL table

    

       
            
 FiberMod_front.jpgFOL_fiber.jpg 
  10778   Thu Dec 11 10:08:10 2014 manasaUpdateGeneralIFO updateStatus of IFO:
1. The X
  
  10780   Thu Dec 11 12:50:12 2014 manasaSummaryGeneralPSL table optical layout I assembled the telescope to couple
PSL light into the fiber. The maximum coupling
that I could obtain was 
  
  10787   Thu Dec 11 23:34:06 2014 manasaSummaryGeneralPSL table optical layout

    

       
            
  
  10788   Fri Dec 12 02:30:25 2014 JenneSummaryGeneralPSL table optical layout

    

       
            
  
  10791   Fri Dec 12 14:38:39 2014 manasaSummaryGeneralFrequency Offset Locking - To Do List (Revised)Unfortunately the order placed for beam
samplers last week did not go through. These
will be used at the X and Y end tables to
 FOLtodolist.pdf 
  10792   Fri Dec 12 15:19:04 2014 manasaSummaryGeneralDec 12 - PSL table

    

       
            
 PSLtoFiber.pngPSLfiberChassis.pngPSLfiberChassis.png 
  10808   Wed Dec 17 11:57:56 2014 manasaSummaryGeneralY arm optical layoutI
was working around the PSL table and Y endtable
today.
 58.png 
  10831   Mon Dec 22 17:06:14 2014 manasaUpdateGeneralX end AUX laser fiber setup

    

       
            
  
  10834   Tue Dec 23 13:18:37 2014 manasaUpdateGeneralX end AUX laser fiber setup

    

       
            
  
  10846   Mon Dec 29 21:30:25 2014 ranaUpdateGeneralrecovery
    Control room is at +66 F. Brrrr.

   Alignment of input beam into the IMC
was wacky; locked on HOM.
    Re-aligned
  
  10867   Wed Jan 7 12:15:17 2015 manasaUpdateGeneralNew RF cablesI was
working around the PSL table this morning.
1. I have fibers running from
  
  10871   Wed Jan 7 14:41:46 2015 SteveUpdateGeneralOphir pmeter filter found

    

       
            
  
  10873   Wed Jan 7 19:49:09 2015 manasaUpdateGeneralX end space issuesI have attached a photo of the ETMX table.
The path of the 1064nm light rejected after
the doubler and the green light are indicated
 ETMXspace.png 
  10874   Wed Jan 7 21:13:35 2015 ranaUpdateGeneralinane LSCoffsets script removed

    

       
            
  
  10880   Thu Jan 8 19:41:50 2015 ericqUpdateGeneralinane LSCoffsets script removedThe restored offset script used old tdsavg
calls that our workstations can't do,
and didn't include things like the transmon
  
  10883   Fri Jan 9 14:01:17 2015 manasaUpdateGeneralAUX Y + PSL beat note at 1064nmI
worked around the PSL table today.

The Y+PSL output from the optical
  
  10884   Fri Jan 9 14:13:02 2015 manasaUpdateGeneralALS noise at ~30HzBefore starting to move things around the
PSL table, I measured the ALS out of loop noise
 ALSYoutLoop.pngLSC_TRY.png 
  10893   Tue Jan 13 10:28:02 2015 manasaUpdateGeneralAUX Y + PSL beat note at 1064nm


  
  10894   Tue Jan 13 13:22:54 2015 JenneUpdateGeneralAUX Y + PSL beat note at 1064nm: needs workI'm super excited about this new frequency
readback, but I'm
  
  10895   Tue Jan 13 14:01:20 2015 manasaUpdateGeneralAUX Y + PSL beat note at 1064nm: needs work


  
  10918   Sat Jan 17 15:07:28 2015 manasaUpdateGeneralBeat note frequency discrepancyI
was around the PSL table and the X end table
today.
  
  10919   Mon Jan 19 11:03:32 2015 manasaUpdateGeneralRF connections to adderRF connections to the beat note adder on
the IOO rack have been undone and it
should be good to proceed with any locking
  
  10955   Thu Jan 29 10:14:21 2015 manasaUpdateGeneralX end space issuesIt is certain that we have space issues
at the X end that has been preventing us
from sticking in a lens to couple light into
 photo.pngdrawing.png 
  10956   Thu Jan 29 11:59:48 2015 manasaUpdateGeneralBeat note frequency discrepancyBelow is the set of plots comparing measurements
for the green and IR beat notes frequencies.
The measurements were made on the spectrum
 Freq_compare1.pngFreq_compare2.png 
  10957   Thu Jan 29 16:14:10 2015 manasaUpdateGeneralUpdated to do list for FOLSince there will be some work that supposedly
will involve moving stuff on the table and
racks; here is the updated to-do list for
 FOLtodolist1.png 
  10964   Mon Feb 2 16:58:56 2015 manasaUpdateGeneralRF amplifier for ALSToday I was around the IOO rack.

I shutdown the power to the beat
PDs on the PSL table and disconnected the
 ALSXY_outLoop.png 
  10970   Tue Feb 3 16:43:48 2015 manasaUpdateGeneralRF amplifier for ALSI pulled out the RF amplifier box from
the IOO rack again and added the new
RF amplifiers for FOL. 
  
  10977   Wed Feb 4 21:05:24 2015 manasaUpdateGeneralRF amplifier for ALSThe components of the RF amplifier
box are in place. The RF amplifier box has
been mounted on the IOO rack and the front
 RFampBox.png 
  10978   Wed Feb 4 21:09:43 2015 manasaUpdateGeneralX endtable work scheduled tomorrowThe X end fiber setup will be put together
tomorrow morning.
  
  10981   Thu Feb 5 15:21:25 2015 manasaUpdateGeneralX endtable work [EricG, Manasa]

We were at the X end today trying
to couple AUX X light into the fiber. 
  
  10985   Fri Feb 6 18:06:18 2015 manasaUpdateGeneralFiber Optic module for FOLI pulled out the Fiber Optic Module for
FOL from the rack inside the PSL table enclosure
and modified it. The beat PDs were moved
 FOLfiberModule.png 
  10996   Tue Feb 10 16:01:21 2015 manasaUpdateGeneralAUX X fiber coupled 72%Plan
C finally worked. We have
 AUXxTelescope.png 
  11006   Wed Feb 11 18:44:53 2015 manasaUpdateGeneralOptical fiber moduleI have moved the optical fiber
module for FOL to the PSL table. It is setup
on the optical table right now for testing.
  
  11013   Thu Feb 12 12:16:04 2015 manasaUpdateGeneralFiber shielding[Steve, Manasa]

The fibers around the PSL table
were shielded to avoid any tampering.
  
  11014   Thu Feb 12 12:23:21 2015 manasaUpdateGeneralWaking up the PDFR measurement system[EricG, Manasa]

We woke up the PDFR measurement
setup that has been sleeping since summer.
  
  11026   Fri Feb 13 19:41:13 2015 ericqUpdateGeneralRF amplifier for ALSAs Koji found one of the spare channels
of the ALS/FOL RF amplifier box nonfunctional
yesterday, I pulled it out to fix it. I found
  
ELOG V3.1.3-