6596
|
Thu May 3 13:19:17 2012 |
Jenne | Update | Locking | More success last night | I locked each arm, and the Michelson last
night, no problems after I increased the
Yarm gain from 0.1 to 0.2 . I checked |
|
6597
|
Thu May 3 13:35:56 2012 |
Jenne | Bureaucracy | General | 40m Meeting Action Items | Action
Items:
IFO |
|
6598
|
Thu May 3 17:15:38 2012 |
Koji | Update | LSC | c1iscaux2 rebooted/burtrestored | [Jenne/Den/Koji]
We saw some white boxes on the LSC
screens. |
|
6599
|
Thu May 3 19:52:43 2012 |
Jenne | Update | CDS | Output errors from dither alignment (Xarm) script | epicsThreadOnceOsd epicsMutexLock
failed.
Segmentation fault |
|
6600
|
Thu May 3 21:13:48 2012 |
Koji | Summary | SUS | ITMX/PRM/BS OPLEV aligned | [Jenne/Den/Koji]
We locked Xarm/Yarm and manually
alignmed ITMX/ITMY/BS/ETMX/ETMY/PZT1/PZT2. |
|
6601
|
Thu May 3 22:37:44 2012 |
Jenne | Update | General | OpLev 90-day trend | After fixing the PRM tonight, all of the
oplevs look okay.
.....except ITMX, which looks like |
|
6602
|
Fri May 4 17:44:42 2012 |
Jenne | Update | General | OpLev 90-day trend |
|
|
6603
|
Fri May 4 17:46:46 2012 |
Jenne | Update | Green Locking | PSL doubling oven back on | While walking past the PSL, I noticed that
the PSL's doubling oven's heater was still
disabled from the power outage. As |
|
6604
|
Sat May 5 01:24:07 2012 |
Den | Update | PSL | PMC | I was interested what whitening filter
do we have between MC servo and ADC. The
shape is in the figure below, SR provided |
 |
6605
|
Sat May 5 09:13:02 2012 |
Koji | Update | PSL | PMC | I suspect that it was just unlocked when
you had disconnected the cable.
There is not reflection now. It seems |
|
6606
|
Sat May 5 10:20:21 2012 |
Den | Update | PSL | PMC |
|
|
6607
|
Sat May 5 12:23:38 2012 |
Koji | Update | PSL | PMC | No matter how you connect/disconnect, touching
the laser may cause the PMC unlocked.
At |
|
6608
|
Sat May 5 20:42:59 2012 |
Den | Update | PSL | PMC | [Koji, Den]
Koji was right that I misaligned
everything during the alignment work. I assumed |
|
6609
|
Sun May 6 00:11:00 2012 |
Den | Update | CDS | mx_stream | c1sus and c1iscex computers could not connect
to framebuilder, I restarted it, did not
help. Then I restarted mx_stream daemon on |
|
6610
|
Sun May 6 01:41:55 2012 |
Den | Update | PEM | seismic in x,y arms | I locked x,y arms and measured coherence
between POS{X,Y}11_I_ERR, MC_F and seismometer
signals. |
|
6611
|
Mon May 7 01:07:58 2012 |
Den | Update | IOO | seismic in mcf | I tried to figure out where additional
(to seismic) noise enters to MC_F, so the
coherence below 1 Hz is low (~0.2-0.5). I've |
   |
6612
|
Mon May 7 12:57:34 2012 |
Den | Update | IOO | WFS noise in MC | I've measured coherence between seismometer
signals and OSEMS of MC 1,2,3
|
   |
6613
|
Mon May 7 17:28:29 2012 |
Den | Update | IOO | WFS noise in MC |
|
|
6614
|
Mon May 7 19:39:52 2012 |
Koji | Update | IOO | WFS noise in MC | OK. Then we should make this number bigger
such that the coherence is still completely
maintained. |
|
6615
|
Mon May 7 20:15:37 2012 |
Den | Update | IOO | WFS noise in MC |
|
|
6616
|
Mon May 7 21:05:38 2012 |
Den | Update | CDS | biquad filter form | I wanted to switch the implementation of
IIR_FILTER from DIRECT FORM II to BIQUAD
form in C1IOO and C1SUS models. I modified |
|
6617
|
Mon May 7 21:19:00 2012 |
Jenne | Update | SUS | ETMX oplev | I'm still not super happy with the low
power level of the ETMX oplev, so I went
to investigate. |
|
6618
|
Mon May 7 21:46:10 2012 |
Den | Update | CDS | guralp signal error | GUR1_XYZ_IN1 and GUR2_XYZ_IN1 are the same
and equal to GUR2_XYZ. |
|
6619
|
Mon May 7 22:39:37 2012 |
Den | Update | CDS | c1sus | [Jenne, Den]
We decided to reboot C1SUS machine
in hope that this will fix the problem with |
|
6620
|
Tue May 8 03:33:24 2012 |
Jenne | Update | SUS | New misalign / restore scripts for IFO_ALIGN screen | Since Den wasn't able to fix c1sus (make
it talk to the framebuilder) before he left
a few hours ago, I decided to do some housekeeping |
|
6621
|
Tue May 8 03:38:28 2012 |
Jenne | Update | General | MEDM svn emergency!!! | We officially are
*failures* at svn-ing our scripts and screens. |
|
6622
|
Tue May 8 09:47:53 2012 |
Jamie | Update | CDS | biquad filter form |
|
|
6623
|
Tue May 8 09:58:17 2012 |
Den | Update | CDS | SUS -> FB | [Alex, Den]
It |
|
6624
|
Tue May 8 10:43:42 2012 |
Den | Update | CDS | biquad filter form |
|
|
6625
|
Tue May 8 16:43:15 2012 |
Jenne | Update | CDS | Degenerate channels, potentially a big mess | Rana
theorized that we're having problems with
the MC error signal in the OAF model (separate |
|
6626
|
Tue May 8 17:48:50 2012 |
Jenne | Update | CDS | OAF model not seeing MCL correctly | Den noticed this, and will write more later,
I just wanted to sum up what Alex said /
did while he was here a few minutes ago.... |
|
6627
|
Wed May 9 00:45:13 2012 |
Jenne | Update | CDS | No signals for DTT from SUS | Upgrades suck. Or at least making
everything work again after the upgrade.
On the to-do list tonight: |
 |
6628
|
Wed May 9 01:14:44 2012 |
Jenne | Update | CDS | No signals for DTT from SUS |
|
|
6629
|
Wed May 9 04:47:20 2012 |
Jenne | Update | Locking | PRM is really moving when PRMI locked | A few things tonight. Locked both
arms simultaneously (IR only). Locked
MICH, Locked PRMI, although it doesn't like |
|
6630
|
Wed May 9 08:21:42 2012 |
Jamie | Update | CDS | No signals for DTT from SUS |
|
|
6631
|
Wed May 9 09:19:22 2012 |
Koji | Update | Locking | PRM is really moving when PRMI locked | Is this enhancement of spectrum caused
by the lock? Or by the actuation?
|
|
6632
|
Wed May 9 10:46:54 2012 |
Den | Update | CDS | OAF model not seeing MCL correctly |
|
|
6633
|
Wed May 9 11:31:50 2012 |
Den | Update | CDS | RFM | I added PCIE memory cache flushing to c1rfm
model by changing 0 to 1 in /opt/rtcds/rtscore/release/src/fe/commData2.c
on line 159, recompiled and restarted c1rfm. |
|
6634
|
Wed May 9 14:32:31 2012 |
Jenne | Update | CDS | Burt restored | Den and Alex left things not-burt restored,
and Den mentioned to me that it might need
doing. |
|
6635
|
Wed May 9 15:02:50 2012 |
Den | Update | CDS | RFM |
|
|
6636
|
Wed May 9 15:50:13 2012 |
Jenne | Bureaucracy | General | 40m Meeting Action Items | I'm combining the IFO check-up list (elog
6595) and last week's action items list |
|
6637
|
Thu May 10 14:49:06 2012 |
Koji | HowTo | General | How to clean & bake black glass pieces | |
|
6638
|
Thu May 10 21:13:01 2012 |
Den | Update | Electronics | ADC 3 | ADC 3 INPUT 4 (#3 in the c1pem model if
you count from 0) is bad. It adds DC = ~1
V to the signal as well as noise. I plugged |
|
6639
|
Thu May 10 22:05:21 2012 |
Den | Update | CDS | FB | Already for the second time today all computers
loose connection to the framebuilder. When
I ssh to framebuilder DAQD process was not |
|
6640
|
Fri May 11 08:07:30 2012 |
Jamie | Update | CDS | FB |
|
|
6641
|
Fri May 11 17:21:56 2012 |
Jenne | Update | IOO | OAF left enabled - MC unlocked for more than an hour | No leaving the OAF running until you're
sure (sure-sure, not kind of sure, not pretty
sure, but I've enabled guardians to make |
|
6642
|
Fri May 11 23:33:41 2012 |
Den | Update | Adaptive Filtering | offline vs online | I've compared offline Wiener filtering
with online static + adaptive filtering for
MC_F with GUR1_XYZ and GUR2_XYZ as witness |
|
6643
|
Mon May 14 08:49:47 2012 |
steve | Update | SUS | ETMY damping restored | ETMY sus damping restored. |
|
6644
|
Tue May 15 08:44:55 2012 |
steve | Update | SUS | ETMX damping restored | ETMX sus damping restored |
|
6645
|
Tue May 15 23:40:46 2012 |
Mike J. | Update | Computers | Image Subtraction | I acquired 2 raw frames of MC2 using "/users/mjenson/sensoray/sdk_2253_1.2.2_linux/capture
-n -s 720x480 -f 1", one while the
laser was off the mode cleaner and another |
  |