40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 131 of 335  Not logged in ELOG logo
ID Date Author Type Category Subjectup Text Attachments
  11541   Sat Aug 29 04:53:24 2015 IgnacioUpdateIOOMCL Wiener Feedforward Final ResultsAfter fighting
relentlessly with the mode cleaner, I believe
I have achieved 
 6x 
  11542   Sun Aug 30 00:03:13 2015 ranaUpdateIOOMCL Wiener Feedforward Final ResultsSomehow it seems like the ELOG makes all
of the thumbnails way too big by default.
Did we get some sneaky upgrade recently?
  
  11543   Sun Aug 30 10:57:29 2015 IgnacioUpdateIOOMCL Wiener Feedforward Final ResultsBig thumbnails? Could it have been this? elog:11498.

Anyways, I fixed the plots and
  
  11544   Sun Aug 30 12:20:08 2015 ericqUpdateIOOMCL Wiener Feedforward Final Results



  
  11545   Sun Aug 30 13:31:48 2015 ranaUpdateIOOMCL Wiener Feedforward Final ResultsI'm not totally sure, but by eyeball,
this seems like the best online MCL reduction
we've ever had. Nice work.
  
  814   Fri Aug 8 11:04:34 2008 SharonUpdate MCL Wiener filterI took some old data from Rana and converted
the units of the Weiner filter to m/m so
to make the effect of the seismometer and
 m_per_m.png 
  11424   Fri Jul 17 04:56:37 2015 IgnacioUpdateGeneralMCL Wiener filtering + FIR to IIR conversion using vectfit 

We took data for the mode cleaner
a while ago, June 30th I believe. This data
 9x 
  11425   Sat Jul 18 06:12:07 2015 IgnacioUpdateGeneralMCL Wiener filtering + FIR to IIR conversion using vectfit (Update)(updateAfter Eric gave me feedback on my
previous elog post, I went back and fixed
some of the silly stuff I stated.
 15x 
  7737   Wed Nov 21 01:36:36 2012 KojiUpdateIOOMCL disabled / WFS clear history restoredAs MCL is disturbing arm locking by injecting
a lot of noise, I have modified 'mcup' 
to disable MCL
  
  8440   Thu Apr 11 03:23:12 2013 DenUpdateGeneralMCL thresholdMC down script is too slow to block MC_L
when the cavity goes out of lock. As a result
the loop strongly kicks MC2. We decided to
  
  7263   Thu Aug 23 22:21:13 2012 ranaConfigurationIOOMCL turned back onI turned on some filters and gain in the
SUS-MC2_MCL filter bank tonight so as suppress
the seismic noise influence on MC_F. This
 mcl-screen.pngmcf-noise.pdf 
  6996   Fri Jul 20 14:18:15 2012 DenUpdatePEMMCL, GUR calibrationI did a raw calibration of MCL and GUR.
Accuracy is a factor of 2.
GUR path : 800 V/m/s => readout
 LIGO_S5_S6.eps 
  7522   Wed Oct 10 20:27:40 2012 DenUpdateIOOMCL, WFS triggersI've added MCL and WFS stop triggers into
C1MCS/SUS model. Threshold value of MC_TRANS
can be changed in the text entry located
 MC2_POS.pngmcl.pdf 
  7572   Thu Oct 18 03:45:56 2012 JenneUpdateIOOMCL, WFS triggers

    

       
            
  
  7575   Thu Oct 18 12:02:32 2012 DenUpdateIOOMCL, WFS triggers

    

       
            
  
  7578   Fri Oct 19 01:11:18 2012 JenneUpdateIOOMCL, WFS triggers

    

       
            
  
  10406   Mon Aug 18 09:42:50 2014 KojiSummaryIOOMCREFL PD charcterizationRiju did the
measurement of the MCREFL PD.
I found data files in her directory
 MCREFLPD_transimpedance.pdfMCREFLPD_transimpedance_zoom.pdf 
  12860   Wed Mar 1 17:25:28 2017 SteveUpdateLSCMCREFL condition picturesGautam and Steve,

 

Our MCREFL rfpd
 IMG_3646.JPGmcRefl_1.jpgmcRefl_3.jpgmcRefl_5.jpg 
  12891   Fri Mar 17 14:49:09 2017 gautamUpdateLSCMCREFL condition picturesI did a quick measurement of the beam size
on the MC REFL PD today morning. I disabled
the MC autolocker while this measurement
 IMG_7219.JPGMCREFL_X.pdfMCREFL_Y.pdf 
  13716   Wed Mar 28 21:47:37 2018 arijitUpdateIOOMCREFL_PD Optical response measurementKevin, Gautam and Arijit

We did a optical measurement of
the MCREFL_PD transimpedance using the Jenny
 LISO_fit_with_info.pdfLISO_fit.zip 
  13719   Thu Mar 29 17:57:36 2018 arijitUpdateIOOMCREFL_PD Optical response measurementKevin, Gautam and Arijit

Today we performed the in-loop
noise measurements of the MCREFL-PD using
 NOISE_EATER_On_OFF.pdf 
  13721   Fri Mar 30 06:14:31 2018 ranaUpdateIOOMCREFL_PD Optical response measurementthe noise eater on/off measurements should
be done for 0-100 kHz and from the demod
board output monitor
  
  13724   Fri Mar 30 22:37:36 2018 KevinUpdateIOOMCREFL_PD Optical response measurement[Gautam, Kevin]

We redid the measurement measuring
the voltage noise from the REFL PD demod
 REFLPD_DemodBoard.pdf 
  2451   Thu Dec 24 19:13:29 2009 KojiUpdateIOOMCT QPD investigationI found that MCT QPD has a dependence of
the total output on the position of the spot.
Since the QPD needs the supply and bias voltages
 D990692.png 
  2454   Sun Dec 27 23:44:59 2009 ranaUpdateElectronicsMCT QPD investigation


   
        
            
  
  2455   Mon Dec 28 01:17:01 2009 KojiUpdateElectronicsMCT QPD investigationUnfortunately, the signals for individual
segments also suffer from the voltage drop
as all of the low impedance amplifiers are
  
  2448   Wed Dec 23 16:34:25 2009 KojiUpdateIOOMCT QPD/MC REFL QPD disabledFor a certain investigation of the sum/diff
module for MCT QPD/MC REFL QPD, I removed
it from the system.
  
  4107   Tue Jan 4 18:37:18 2011 JenneUpdateIOOMCWFS alignedI undid Yuta's
temporary setup, and put beam back on both
  
  1405   Mon Mar 16 01:20:40 2009 ranaConfigurationIOOMCWFS noise filtered on the SUS-MC [SIZE=4][COLOR=darkgreen]Recently[/COLOR][/SIZE],
we noticed that the IOO-WFS system runs at
2048 Hz and sends its signals to the MC SUS
 xarm.png 
  5869   Fri Nov 11 00:55:53 2011 DenUpdateAdaptive FilteringMC_F[Mirko, Den]
Not satisfactory work of adaptive
filtering make us to think about the signals
 mcl_sim.jpgmcl_real.jpg 
  5871   Fri Nov 11 10:30:27 2011 ranaUpdateAdaptive FilteringMC_F 
 There should be a whitening
filter in the Pentek Generic DAQ board (Eurocard
  
  15857   Wed Mar 3 12:00:58 2021 Paco, AnchalHowToIMCMC_F ASD[Paco, Anchal]

- Saved BURT backup in /users/anchal/BURTsnaps/
- Copied existing code for mode cleaner
 20210303_MC_F_Spectrum.pdf20210303_MC_F_Spectrum.tar.gz 
  553   Mon Jun 23 19:33:01 2008 rana, jenneUpdateIOOMC_F Noise checkWe looked at the MC_F spectrum because Rob
and Yoichi said that it had gone 'all crazy'.
It
 mcf.png 
  993   Thu Sep 25 15:24:05 2008 YoichiUpdateIOOMC_F VCO calibrationI calibrated the VCO driving the AOM for the
AO path of the MC feedback.
 VCO_Cal.png 
  1032   Tue Oct 7 21:19:40 2008 YoichiUpdateIOOMC_F calibrated spectrum[COLOR=darkred]I updated the plots because
I did not take into account the double path
AOM effect, which doubles the frequency actuation
 MC_F-spectrum.pngVCO_VoverMC_F.pngPSL_FoverMC_F.png 
  11281   Mon May 11 13:26:02 2015 manasaUpdateIMCMC_F calibrationThe last MC_F calibration was done by Ayaka
: Elog
7823
  
  11284   Mon May 11 18:14:52 2015 ranaUpdateIMCMC_F calibrationI saw that entry, but it doesn't state
what the calibration is in units of Hz/counts.
It just gives the final calibrated spectrum.
  
  1747   Wed Jul 15 11:38:31 2009 robUpdateLockingMC_F channel deadIt's railed.  This is what halted
locking progess on Monday night, as this
channel is used for the offloadMCF script,
 mcfdead.png 
  1758   Thu Jul 16 14:41:38 2009 robUpdateLockingMC_F channel dead


   
        
            
 IOO_ICS_0_15.pngIOO_ICS_15_32.png 
  1759   Thu Jul 16 14:54:05 2009 robUpdateLockingMC_F channel dead


   
        
            
  
  3231   Thu Jul 15 19:13:03 2010 ranaUpdateIOOMC_F checkSometimes I like to plot the spectrum of
MC_F. Its a good diagnosis of whether something
is wrong.
 a.png 
  6689   Sat May 26 00:08:41 2012 DenUpdateIOOMC_F low frequency noise MC_F low frequency noise might be
due to local damping electronics. I did not
measure OSEM noise, but even without it electronics
 osem_noise.pnggur_suspos_coh.pngmc_noises.pngdgur.pngratio.png 
  7003   Mon Jul 23 17:39:34 2012 JenneUpdateIOOMC_F vs. MC_L[Rana, Jenne]
We looked at the different outputs
of the MC servo board to make sure they make
 MCF_vs_MCL_23July2012.pdf 
  968   Fri Sep 19 00:06:54 2008 ranaUpdateIOOMC_F: Too much frequency noise around 100 HzWE noticed this excess again in MC_F. We tried
recentering the WFS, but no effect.
 mcf.png 
  1393   Thu Mar 12 02:18:42 2009 YoichiUpdateLockingMC_I spectra (RF_AM)I took several spectra of MC_I signal (see
attm1).
 MC_I_Spe.pngMC_I-Xarm.png 
  999   Fri Sep 26 16:13:57 2008 ranaUpdateIOOMC_L / MC_F crossoverWe were trying to understand why the FAST_F
signal had such large excursions (~1V ~ 5
MHz).
 mcx.png 
  7750   Tue Nov 27 00:45:20 2012 jamieUpdateIOOMC_L and laser frequency noise spectraI grabbed the a plot of the iLIGO PSL frequency
noise spectrum from the Rana manifesto:
 laser_noise.pdfMCL_noise.pdf 
  2062   Wed Oct 7 06:26:09 2009 ranaHowToIOOMC_L calibration + some DTT loreI drove MC2 in POS and used the
resulting response in MC_F to calibrate the
IOO-MC_L channel.
 mcl-cal.pnga.png 
  1768   Tue Jul 21 15:32:47 2009 JenneUpdateIOOMC_L flatlined[Clara, Jenne]
While Clara was working on her Wiener
filtering and optimizing the locations of
  
  1770   Tue Jul 21 17:52:12 2009 JenneUpdateIOOMC_L flatlined


   
        
            
  
ELOG V3.1.3-