ID |
Date |
Author |
Type |
Category |
Subject |
Text |
 |
5731
|
Mon Oct 24 20:00:21 2011 |
Mirko | Update | CDS | Tiny little scripts | Located in /opt/rtcds/caltech/c1/userapps/release/cds/common/scripts
Script 1: Diagreset.sh
Hits the diag reset buttons on the |
|
5738
|
Tue Oct 25 20:04:40 2011 |
Mirko | Update | Adaptive Filtering | Adaptive filter witness and EP SNR | We currently have the code running for
all DOFs using all witness channels. By default
nothing is applied. C-Code parameters can |
 |
5758
|
Fri Oct 28 15:45:52 2011 |
Mirko | Update | Computers | Nifty screen generator |
|
|
5763
|
Sat Oct 29 22:57:03 2011 |
Mirko | Update | LSC | AM modulation due to non-optimal SB frequency | [Kiwamu, Mirko]
Non-optimal 11MHz SB frequency causes
PM to be transformed into AM. |
|
5774
|
Tue Nov 1 13:41:38 2011 |
Mirko | Update | LSC | AM modulation due to non-optimal SB frequency |
|
|
5811
|
Fri Nov 4 15:24:13 2011 |
Mirko | Update | Adaptive Filtering | Adaptive FF on the MC doesn't make sense | [Den, Jenne, Mirko]
|
|
5841
|
Tue Nov 8 17:48:21 2011 |
Mirko | Update | CDS | Dolphin weirdness | Had since yesterday evening some trouble
with getting a channel from rfm on c1sus
to oaf on c1lsc via dolphin. Several restarts |
|
5842
|
Tue Nov 8 18:06:43 2011 |
Mirko | Update | Adaptive Filtering | Noise injections to MC1-3 PIT & YAW | With fancy analysis tools approaching usability
I looked some more into noise projections
from PIT,YAW motion of the MC mirrors to |
7x |
5843
|
Tue Nov 8 19:08:21 2011 |
Mirko | HowTo | Computers | New DV | [quote]To use the new ligoDV (previously GEO
DV) to look at 40m data, open up a matlab,
set up for mDV as usual,
|
|
5847
|
Wed Nov 9 13:44:04 2011 |
Mirko | Update | Computers | NDS1 missing channels in matlab | The Matlab NDS1 access seems to only work
for some channels. With other channels it
just hangs 'Busy' and does nothing. |
|
5856
|
Wed Nov 9 20:35:58 2011 |
Mirko | Update | Adaptive Filtering | Seismic noise injection into the MC | Very elaborated measurement ;-)
On 11-11-08:
18:40 Stomp near STS1 for 2mins |
8x |
5858
|
Wed Nov 9 21:32:38 2011 |
Mirko | Update | Adaptive Filtering | Put accelerometers 4-6 on top of MC2 tank | Put the accelerometers on top of MC2. Orientated
as the arms,GUR1 and STS1:
|
  |
5863
|
Thu Nov 10 16:26:46 2011 |
Mirko | Update | Computers | Firefox kills elog | Had to restart the elog many times. For
some reason firefox 8 on Win 7 kills the
elog pretty consistently when trying to make |
|
5864
|
Thu Nov 10 16:44:54 2011 |
Mirko | Update | Adaptive Filtering | Looking into MC_F & PSL misalignment | [Den, Mirko]
While doing the things below we accidentally
misaligned the PSL laser. Thanks to Suresh |
 |
5867
|
Thu Nov 10 22:00:38 2011 |
Mirko | Update | Adaptive Filtering | Looking into MC_F & PSL misalignment |
|
6x |
5879
|
Sat Nov 12 02:00:36 2011 |
Mirko | Update | Adaptive Filtering | MC-F and other signals | Regarding http://nodus.ligo.caltech.edu:8080/40m/5867
and http://nodus.ligo.caltech.edu:8080/40m/5869
: |
    |
5900
|
Tue Nov 15 22:31:39 2011 |
Mirko | Update | Adaptive Filtering | Towards wiener filtering and improved OAFing |
[Jenne, Mirko]
1. We should help the OAF by compensating |
7x |
5901
|
Tue Nov 15 23:44:44 2011 |
Mirko | Update | CDS | C1:LSC & C1:SUS restarted | Earlier this evening C1:LSC died then I
hit the DAQ reload after adding an OAF channel
to be recorded. No change to any model. Had |
|
5915
|
Wed Nov 16 17:40:48 2011 |
Mirko | Update | IOO | MC unlocked and misaligned. | MC fell out of lock and was then quite
badly misaligned. Mostly in pitch. I realigned
it and it locked ok. |
|
5949
|
Fri Nov 18 15:45:11 2011 |
Mirko | Update | IOO | Mode cleaner noise projection | [Rana, Den, Mirko]
Updated the MC noise projection to
include the longitudinal motion of the MC |
 |
5952
|
Fri Nov 18 19:57:19 2011 |
Mirko | Update | IOO | Mode cleaner noise projection |
Some more info on this:
|
  |
5960
|
Sat Nov 19 12:57:55 2011 |
Mirko | Update | IOO | Mode cleaner noise projection |
|
 |
5961
|
Sat Nov 19 15:58:04 2011 |
Mirko | Update | IOO | Some more looks into OSEM noise | [Den, Mirko]
We looked some more into the the
OSEM signals and their coherence to the seismometer |
8x |
5969
|
Mon Nov 21 15:47:58 2011 |
Mirko | Update | IOO | Osem loop shape | [Jenne, Mirko]
To
reiterate: We changed the OSEM loop shape |
|
5971
|
Mon Nov 21 17:07:34 2011 |
Mirko | Update | CDS | c1pem model dead | For some reason C1PEM doesn't seem to work
anymore after a recompilation. It did recompile
fine. We just changed some channel / subsystem |
|
5973
|
Mon Nov 21 22:51:55 2011 |
Mirko | Update | CDS | c1pem model dead |
|
|
5981
|
Tue Nov 22 20:45:21 2011 |
Mirko | Update | IOO | Measurement of the actuator matrix | Tried measuring the actuator matrix for
MC1.
With the watchdogs tripped I cut |
|
5986
|
Wed Nov 23 02:34:28 2011 |
Mirko | Update | PEM | Seismic spectrum & Striptool | The Striptool for the BLRMS seismic channels
is running now. Channels are ( still ) recorded
as slow EPICS channels. |
|
6004
|
Thu Nov 24 20:22:42 2011 |
Mirko | Update | IOO | F2A filter for MC | I calculated the F2A filters for the input
mode cleaner optics as described in T010140-01-D
eq (4). On Ranas recommendation I added an |
 |
6005
|
Fri Nov 25 12:46:13 2011 |
Mirko | Update | WienerFiltering | Wiener filtering tryout | Tried the wiener filter with the TF from
p.5900
Tried it out with the TFs from p.5900: |
|
6011
|
Fri Nov 25 22:11:12 2011 |
Mirko | Update | CDS | Beware of fancy filter modules | [Rana, Den, Mirko]
It seems you can shoot yourself in
the foot if your filter modules are too complex. |
   |
6012
|
Fri Nov 25 23:25:24 2011 |
Mirko | Update | IOO | F2A filter for MC |
|
|
6013
|
Sat Nov 26 02:05:43 2011 |
Mirko | Update | CDS | Beware of fancy filter modules |
We replaced the complicated Cheby
filter module with three separate filter |
|
6014
|
Sat Nov 26 02:15:42 2011 |
Mirko | Update | SUS | Not adaptive, still cool | [Rana, Mirko]
I tried out the virtual pendulum
idea today. The idea is to compensate the |
  |
6057
|
Thu Dec 1 03:27:39 2011 |
Mirko | Update | SUS | Not adaptive, still cool |
|
|
2091
|
Wed Oct 14 15:48:26 2009 |
Mott | HowTo | General | Phase Noise measurement | I have gotten the hang of the procedure
for measuring phase noise on the AOMs.
Koji suggested I right up a short |
|
2117
|
Mon Oct 19 13:00:53 2009 |
Mott | Update | General | Phase Noise Measurement | Here is the result for the measurement
of the phase noise. We used the marconi
function generator and compared it with an |
  |
2362
|
Mon Dec 7 19:02:22 2009 |
Mott | Update | General | Reflectivity Measurements | I have made some measurements of the R
value for some coatings we are interested
in. The plots have statistical error |
  |
2392
|
Thu Dec 10 18:27:48 2009 |
Mott | Update | General | Updated R & T Measurements | Attached are updated plots of the T&R
Measurements for a variety of mirrors, and
diagrams for the setup used to make the measurements. |
6x |
2474
|
Mon Jan 4 17:26:01 2010 |
Mott | Update | General | T & R plots for Y1 and Y1S mirrors | The most up-to-date T and R plots for the
Y1 and Y1S mirrors, as well as a T measurement
for the ETM, can be found on: |
|
2696
|
Mon Mar 22 22:11:26 2010 |
Mott | Update | ABSL | PLL reconstructed |
It looks like the PLL drifted
alot over the weekend, and we couldn't get |
|
2697
|
Mon Mar 22 23:37:32 2010 |
Mott | Update | ABSL | PLL reconstructed |
We have managed to lock the PLL to
reasonable stability. The RF input is attenuated |
 |
2703
|
Tue Mar 23 18:44:46 2010 |
Mott | Update | ABSL | PLL reconstructed |
After realigning and getting
the lock today, I tried to add in the SR785 |
|
2729
|
Mon Mar 29 15:26:47 2010 |
Mott | HowTo | Computers | New script for controlling the AG4395A | I just put a script in the /cvs/cds/caltech/scripts/general/netgpibdata/
directory to control the network analyzer
called AG4395A_Run.py . A section |
|
2738
|
Wed Mar 31 03:45:49 2010 |
Mott | HowTo | Computers | New script for controlling the AG4395A |
I took data for the 2 NPRO PLL using
the script I wrote for the AG4395, but it |
|
2746
|
Thu Apr 1 00:43:33 2010 |
Mott | Update | General | PZT response for the innolight | Kiwamu and I measure the PZT response of
the Innolight this evening from 24 kHz to
2MHz. |
|
2748
|
Thu Apr 1 10:21:58 2010 |
Mott | Update | General | PZT response for the innolight |
|
 |
2754
|
Thu Apr 1 18:05:29 2010 |
Mott | Update | General | PZT response for the innolight |
We realized that we had measured
the wrong calibration value; we were using |
 |
2756
|
Thu Apr 1 19:59:32 2010 |
Mott | Update | General | PZT response for the innolight |
We measured the Amplitude Modulation
response of the PZTs, to find regions with |
    |
2799
|
Tue Apr 13 19:53:06 2010 |
Mott | Update | Green Locking | PZT response for the innolight and lightwave |
I redid the PZT Phase Modulation
measurement out to 5 MHz for both the Innolight |
6x |