ID Date Author Type Category Subjectup Text Attachments
  10784   Thu Dec 11 18:00:43 2014 ericqUpdateComputer Scripts / ProgramsMC error signal monitoringThe other day, I hooked up the agilent
analyzer to OUT2 of the MC board, which is
currently set to output the MC refl error
  
  8575   Tue May 14 20:30:29 2013 JamieSummaryIOOMC error spectrum at various FSS gain settings.I used the Agilent 4395A and the GPIB network
bridge to measure the MC error spectrum at
the MC servo board.
 7x 
  4145   Wed Jan 12 22:19:54 2011 KojiUpdateIOOMC flakiness solved[Koji Suresh Kiwamu]
Suresh modified the MC board to have
+5V offset at the output. (To be reported
  
  1081   Fri Oct 24 10:06:16 2008 YoichiConfigurationIOOMC gain and FSS gain changedFollowing the measurements of MC and FSS loop
gains, I modified mcup script to set the
MC VCO gain to 2dB (it was -4dB before).
  
  1435   Fri Mar 27 02:40:06 2009 peteSummaryIOOMC glitch investigationYoichi, Pete
The MC loses lock due to glitches
in the MC1 coils. 
We do
 MC1_Drift.png 
  1437   Fri Mar 27 15:05:42 2009 YoichiUpdateIOOMC glitch investigationAttached plots are the result of the
MC1 trend measurement.
See the
attachment #1. The first two plots show the
 MC1_Drift.pdfMC2_Drift.pdf 
  1438   Fri Mar 27 17:52:16 2009 YoichiUpdateIOOMC glitch investigationPer Rob's suggestion, I put the probes
across the output resistors of the bias current
buffers instead of measuring the output voltage
  
  6899   Sun Jul 1 13:20:09 2012 yutaUpdateIOOMC in low powerI modified autolocker for MC in low power
mode (/opt/rtcds/caltech/c1/scripts/MC/autolockMCmain40m_low_power)
to make it work with the current directory
  
  6910   Tue Jul 3 20:51:06 2012 yutaUpdateIOOMC in vacuum is backMC came back to the state as it was before
the vent.
 ALL_1025408289.bmp 
  2643   Fri Feb 26 11:48:36 2010 KojiUpdateGeneralMC incident beam shiftLast night I worked on the MC incident
beam such that we can hit the center of the
MC mirrors.
  
  2899   Sat May 8 02:38:08 2010 KojiSummaryIOOMC incident powerAs per Steve's request I checked the
MC incident power as a function of time.
The output is negative: the lower
 MC_input.png 
  5725   Fri Oct 21 16:06:12 2011 SureshUpdateComputer Scripts / ProgramsMC input matrices empty againThe MC suspensions were not damping and
the reason was traced to the empty imput
matrices in the suspension controls. 
  
  5367   Thu Sep 8 20:13:24 2011 kiwamuUpdateIOOMC is back to full power[Suresh / Kiwamu]
 The
  
  6292   Fri Feb 17 01:02:22 2012 kiwamuUpdateIOOMC is back to normal[Koji / Kiwamu]
 The
MC is now back to normal. The beam pointing
 MCconnections.png 
  5115   Thu Aug 4 01:49:08 2011 SureshUpdateIOOMC is lockedI measured the power transmitted from the
PSL to the MC.
It is 19mW.
  
  11739   Mon Nov 9 09:27:44 2015 SteveUpdatePSLMC is not happyI just turned off the PSL enclousure lights.
 
 ioo8d.png 
  3779   Mon Oct 25 23:10:06 2010 KojiUpdateIOOMC is now flashing[Suresh / Koji]
The MC
  
  920   Thu Sep 4 07:46:10 2008 YoichiUpdateIOOMC is now happyThe MC has been locked for more than 12 hours
continuously now !
Changes I made yesterday were:
 MC-lock.png 
  3350   Mon Aug 2 21:52:57 2010 KojiUpdateIOOMC is running at the full power[Nancy and Koji]
We restored the full power operation
of the MC.
  
  3383   Sat Aug 7 11:07:44 2010 KojiConfigurationPSLMC kept locked / PMC control gain reduced to +13dBJenne asked us to keep th MC locked
and let the seismometers happy through this
weekend.
  
  952   Wed Sep 17 12:55:28 2008 robConfigurationIOOMC lengthI measured the mode cleaner length last night:

[code]
  
  1664   Wed Jun 10 01:52:34 2009 AlbertoUpdateElectronicsMC length and Marconis' frequenciesPete, Rob, Alberto,
yesterday we thought that some of
the problems we were having in locking the
  
  752   Tue Jul 29 01:03:17 2008 robConfigurationIOOMC length measurementrob, yoichi

We measured the length of the mode cleaner
  
  753   Tue Jul 29 09:12:43 2008 KojiConfigurationIOOMC length measurementI found that the prev modulation freq had
been determined with a same kind of measurement
by Osamu, which also looked accurate.
  
  16222   Wed Jun 23 09:05:02 2021 AnchalUpdateSUSMC lock acquired back againMC was unable to acquire lock because the
WFS offsets were cleared to zero at some
point and because of that MC was very misaligned
  
  16223   Thu Jun 24 16:40:37 2021 KojiUpdateSUSMC lock acquired back again[Koji, Anchal]

The issue
of the PD output was that the PD whitened
 P_20210624_163641_1.jpg 
  12878   Thu Mar 9 20:38:19 2017 ranaConfigurationIOOMC lock acquisition settings changed; no more HOM locksThe MC was sort of misaligned. It was locking
on some vertical HOMs. So I locked it and
aligned the suspensions to the input beam
  
  5551   Mon Sep 26 20:04:03 2011 KojiUpdatePSLMC lock has been recovered[Kiwamu Suresh Koji]
Some main parameters of the PSL has
been recovered using Dataviewer and some
 snapshot1.pngsnapshot2.pngsnapshot3.png 
  1428   Wed Mar 25 17:22:58 2009 YoichiUpdateIOOMC lock without FSSI made 40k:4k passive filter in a POMONA box
and connected it to IN1 (not TEST IN1) of
the FSS box.
 MC-loop-gain.png 
  757   Tue Jul 29 18:15:36 2008 robUpdateIOOMC locked
I used the SUS DRIFT MON screen to return
the MC suspensions to near their pre-quake
  
  1633   Sat May 30 12:03:34 2009 robUpdatePSLMC lockedI locked to PSL loops, then tweaked the
alignment of the MC to get it to lock. 
I first steering MC1 until all the
  
  5939   Fri Nov 18 01:27:04 2011 DenUpdateIOOMC locked[Mirko, Den]
While the MC was unlocked (and the
local damping off) we've measured the coherence
 cohnolocalpumping-crop_4.pdfcohlocalpumping4-crop.pdfcohlock4-crop.pdf 
  8142   Sat Feb 23 00:36:52 2013 ManasaSummaryLockingMC locked[Yuta, Manasa, Sendhil, Rana]

With MC REFL PD fixed, we aligned
 MCdecenter_23Feb2013.png 
  14793   Sun Jul 21 20:23:35 2019 ranaUpdateIOOMC lockedI found the MC2 face camera disabled(?)
and the MC servo board input turned off.
I turned the MC locking back on but I don't
  
  14797   Mon Jul 22 13:26:41 2019 KruthiUpdateIOOMC lockedThe MC2 has 2
GigE cameras right now. I'll
put back the analog asap.
  
  3791   Wed Oct 27 02:26:15 2010 kiwamuUpdateIOOMC locked (Rana, Koji, Suresh, Yuta, Thanh, Kiwamu)
 M
  
  7591   Tue Oct 23 00:41:55 2012 JenneUpdateAlignmentMC locked, spots centered[Jenne, Raji]
We replaced the MC Refl path BS with
the Y1, as usual, so that the full ~100mW
 Screenshot-Figure_1.png 
  7702   Tue Nov 13 00:28:10 2012 AyakaUpdateIOOMC locked, spots centered[Rana, Ayaka, Jenne]
We aligned the REFL beam to the center
of PD.
 spot1112.pngDSC_4902.JPGDSC_4904.JPG 
  8469   Mon Apr 22 11:46:09 2013 KojiSummaryIOOMC locked/aligned. MC WFS offloading by ezcaservoЕру ьс шы
тщц дщслув
фтв фдшптувю
  
  8471   Mon Apr 22 17:06:42 2013 ranaSummaryIOOMC locked/aligned. MC WFS offloading by ezcaservo 
 Why use the PSL beam as a reference?
Don't we want to keep the MC pointing in
  
  1229   Thu Jan 15 09:19:32 2009 steveUpdateIOOMC locking MC2 sus damping was found tripped at the morning
the second time this week.
  
  8424   Mon Apr 8 22:43:44 2013 ranaUpdatePSLMC locking troubles: MC/FSS servo unstableThe MC seemed to be losing lock recently
quite a bit. I noticed that the PC Drive
RMS signal was red.
 Untitled.png 
  1821   Mon Aug 3 14:47:53 2009 JenneUpdateIOOMC locks againThe mode cleaner seems to be locking again. 
I've manually unlocked it a few times in
the past 20min, and most of the time it catches
  
  125   Tue Nov 27 15:47:17 2007 robConfigurationIOOMC loopAfter the FSS running pretty quick, I checked
the MC loop.  I used TPA 1&2.
 MCsmall.jpg 
  126   Tue Nov 27 16:18:58 2007 robConfigurationIOOMC loopReduced the common gain to 22dB in the [COLOR=blue]mcup[/COLOR]
script, so that the WFS would not blow the
lock.  The above measure of the OLG was done
  
  10851   Sun Jan 4 22:08:46 2015 ranaUpdateIOOMC loop characterizations: PZT/EOM crossover * PMC + MC were unlocked when I came
in.
* I fiddled around some more with
 MC_OLGs.pdfMC_xover.pdf 
  8906   Tue Jul 23 13:55:08 2013 KojiUpdateIOOMC manually alignedThe MC was manually aligned. The spot positions
were measured and it is consistent with the
measurements done yesterday.
 MCalignment.pngMCspot.png 
  9030   Mon Aug 19 11:30:20 2013 JenneUpdateIOOMC mirrors' ASC has non-zero inputs[Masayuki, Jenne]
When I came in this morning, I noticed
that the Mode Cleaner had not been locked
  
  9032   Mon Aug 19 15:23:07 2013 KojiUpdateIOOMC mirrors' ASC has non-zero inputs[Jenne, Koji]
This disturbance in the MC ASC channels
were fixed.
  
  5236   Mon Aug 15 10:58:52 2011 kiwamuUpdateIOOMC misaligned a lotThis morning Steve and I opened the doors
on the IOO and OMC chamber to let the IR
beam go to MC.
  
ELOG V3.1.3-