40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 127 of 344  Not logged in ELOG logo
ID Date Authordown Type Category Subject Text Attachments
  14469   Fri Feb 22 12:19:46 2019 gautamUpdateIOOTT coil driver VmonTo debug the issue of the suspected drifting
TTs further, I temporarily hijacked CH0-CH8
of ADC1 in the c1lsc expansion chassis, and
  
  14471   Wed Feb 27 21:34:21 2019 gautamUpdateGeneralSuspension diagnosisIn my effort to understand what's going
on with the suspensions, I've kicked
all the suspensions and shutdown the watchdogs
  
  14472   Sat Mar 2 14:19:35 2019 gautamUpdateCDSFSS Slow servo gains not burt-edPSL NPRO PZT voltage showed large low frequency
(hour timescale) excursions on the control
room StripTool trace, leading me to suspect
  
  14473   Sun Mar 3 14:16:31 2019 gautamUpdateIOOMegatron hard-rebootedIMC was not locked for the past several
hours. Turned out MC autolocker was stuck,
and I could not ssh into megatron because
  
  14474   Tue Mar 5 15:56:27 2019 gautamSummaryTip-TIltDiscussion points about TT re-designChub, Koji and I have been talking about
Udit's re-design. Here are a few points
that were raised. Chub/Koji can add to/correct
  
  14475   Thu Mar 7 01:06:38 2019 gautamUpdateALSALS delay line electronicsSummary:

The restoration of the delay-line
electronics is complete. The chassis has
  
  14477   Tue Mar 12 22:51:25 2019 gautamUpdateALSALS delay line electronicsThis
Hanford alog may be of relevance as we
are using the aLIGO AA chassis for the IR
  
  14478   Wed Mar 13 01:27:30 2019 gautamUpdateALSALS delay line electronicsThis test was done, and I determine the
frequency discriminant to be 
 DFDcal.pdfDFDnoise.pdf 
  14480   Sun Mar 17 00:42:20 2019 gautamUpdateALSNF1611 cannot be shot-noise limited?Summary:

Per the manual (pg12)
of the NF 1611 photodiode, the "Input
 PDnoise.pdf 
  14483   Mon Mar 18 12:27:42 2019 gautamUpdateGeneralIFO status
c1iscaux2
VME crate is damaged -
 IMG_7343.JPGITMXOL.png 
  14484   Mon Mar 18 17:06:12 2019 gautamUpdateOptical LeversITMY HeNe replacedOplev HeNe was replaced this afternoon.
We did some HeNe shuffling:


A new HeNe was being used
 OLRIN.pdfOL_PIT.pdfOL_YAW.pdf 
  14486   Mon Mar 18 20:22:28 2019 gautamUpdateALSALS stability testI'm running a test to see how stable
the EX green lock is. For this purpose, I've
left the slow temperature tuning servo on
  
  14498   Thu Mar 28 19:40:02 2019 gautamUpdateALSBeatMouth with NF1611s assembledSummary:

The parts I was waiting for arrived.
I finished the beat mouth assembly, and did
 IMG_7381.JPGIMG_7382.JPGrelTF_schem.pdfdarkNoise.pdf 
  14501   Fri Mar 29 15:47:58 2019 gautamUpdateAUXAUX laser fiber moved from AS table to PSL table[anjali, gautam]

To facilitate the 1um MZ frequency
stabilization project, I decided that the
  
  14502   Fri Mar 29 21:00:06 2019 gautamUpdateALSBeatMouth with NF1611s installed
Newfocus 15V current limited supply
was taken from bottom NE corner of the ITMY
Oplev table to power the BeatMouth on the
 IMG_7384.JPGIMG_7385.JPG 
  14503   Sun Mar 31 15:05:53 2019 gautamUpdateALSFiber beam-splitters not PMI looked into this a little more today.


Looking at the beat signal
between the PSL and EX beams from the
 IMG_7384.JPG 
  14506   Mon Apr 1 22:33:00 2019 gautamUpdateCDSITMY freedWhile Anjali is working on the 1um MZ setup,
the pesky ITMY was liberated from the OSEMs.
The "algorithm" :
  
  14507   Tue Apr 2 14:53:57 2019 gautamUpdateCDSc1vac added to burtI deleted references to c1vac1 and c1vac2
(which no longer exist) and added c1vac to
the autoburt request file list at 
  
  14509   Tue Apr 2 18:40:01 2019 gautamUpdateVACVac failureWhile glancing at my  vacFail.png 
  14510   Wed Apr 3 09:04:01 2019 gautamUpdateALSNote about new fiber couplersThe new fiber beam splitters we are ordering,
PFC-64-2-50-L-P-7-2-FB-0.3W,
have the slow axis working and fast axis
  
  14511   Wed Apr 3 09:07:46 2019 gautamUpdateVACVac failureOvernight pressure trends don't suggest
anything went awry after the initial interlock
trip. 
 vacFailOvernight.png 
  14512   Wed Apr 3 10:42:36 2019 gautamUpdateVACTP2 forepump replacedBob and Chub concluded that the drypump
that serves as TP2's forepump had failed.
Steve had told me the whereabouts of a spare
  
  14515   Wed Apr 3 18:35:54 2019 gautamUpdateVACPSL shutter re-openedPSL shutter was re-opened at 6pm local
time. IMC was locked. As of 10pm, the main
volume pressure is already back down to the
  
  14516   Fri Apr 5 00:33:58 2019 gautamUpdateALSPromising IR ALS noiseSummary:

I set up a free-space
beat on theNW side of the PSL table between
 IMG_7388.JPGfreeSpace_IR_beat.pdf 
  14517   Fri Apr 5 01:10:18 2019 gautamUpdateVACTP3 forepump is also noisyIs this one close to failure as well?   
  14519   Fri Apr 5 11:49:30 2019 gautamUpdateALSPSL + X green beat recoverySince we haven't been using it, the
PID control was not enabled on the doubling
oven on the PSL table (it is disabled after
  
  14521   Mon Apr 8 00:04:08 2019 gautamUpdateALSIR ALS noise budgetTo start the noise budgeting, I decided
to measure the "DFD noise", which
is really the quadrature sum of the following
 DFDnoise.pdf 
  14522   Mon Apr 8 11:53:17 2019 gautamUpdateCDSc1oaf needs debuggingI tried restarting c1oaf this weekend to
see if turning on the MC length FF would
affect the ALS noise performance. I burtrestored
 c1oaf_sat.pngMCL_FF_TF.pdf 
  14523   Mon Apr 8 18:28:25 2019 gautamUpdateALSEX Green PDH checkoutI worked on characterizing the green PDH
setup at EX, as part of the ALS noise budgeting
process. Summary of my findings:
 IMG_7393.JPGgreenModeMatch.pdf 
  14524   Mon Apr 8 23:52:09 2019 gautamUpdateALSEX Green PDH error monitor calibratedSome time ago, I had done an actuator
calibration of ITMX. This suspension
hasn't been victim to the recent spate
 errMonCalib.pdferrMon.pngOLTF.pdfEX_frequencyNoises.pdf 
  14526   Tue Apr 9 00:18:19 2019 gautamUpdateALSEX Green PDH error monitor calibratedwrong assumption - i checked the gain just
now, it is G=10, and is running in the "low-noise"
mode, so can only drive 4V. fixed elog, filter.
  
  14527   Tue Apr 9 18:44:00 2019 gautamUpdateALSEX Green PDH discriminant measurementI decided to use the more direct method,
of disconnecting feedback to the EX laser
PZT, and then looking at the cavity flashes. 
 cavityFlashes.pdfmodelPDH.pdf 
  14528   Tue Apr 9 19:07:12 2019 gautamUpdateALSIR ALS noise budgetUpdated the noise budget to include the
unsuppressed frequency noise from the EX
laser. It does not explain the noise
 ALS_noiseBudget.pdfALS_noiseBudget.pdf 
  14531   Wed Apr 10 22:59:22 2019 gautamUpdateIOOSpooled fiberSteve had showed me some stock of long
fibers a while back - they are from Oz Optics,
and are 50m long, and are already spooled
  
  14532   Wed Apr 10 23:37:59 2019 gautamUpdatePSLPSL fan is noisyAttached is my phone recording of what
it sounds like right now in the PSL enclosure
- not good for frequency noise measurement!
 New_Recording.m4a 
  14533   Thu Apr 11 01:10:05 2019 gautamUpdateALSLarge 2kHz peak (and harmonics) in ALS XThese weren't present last week. The
peaks are present in the EX PDH error monitor
signal, and so are presumably connected with
 EX_PDH_2kNoise.pdf 
  14541   Mon Apr 15 10:20:44 2019 gautamUpdateOptical LeversBS Oplev PIT was oscillatingThe AS spot on the camera was oscillating
at ~3 Hz. Looking at the Oplevs, the culprit
was the BS PIT DoF. Started about 12 hours
 BS_OL_oscillating.png 
  14544   Mon Apr 15 22:39:10 2019 gautamUpdateFrequency noise measurementAlternate setup with PSL pickoff[anjali, gautam]

just main points, anajli is going
to fill out the details.
  
  14545   Mon Apr 15 22:55:34 2019 gautamFrogsThermal CompensationLab thermostat adjustedIt is feeling cold in the office area.
According to the digital wall clock near
the coffee machine, it is 19C. Rana bumped
  
  14546   Tue Apr 16 22:06:51 2019 gautamUpdateVACVac interlock tripped againThis happened again, about 30,000 seconds
(~2:06pm local time according to the logfile)
ago. The cited error was the same -
 Screenshot_from_2019-04-16_22-05-47.pngScreenshot_from_2019-04-16_22-06-02.png 
  14547   Wed Apr 17 00:43:38 2019 gautamUpdateFrequency noise measurementMZ interferometer ---> DAQ
Delay fiber was replaced with 5m
(~30 nsec delay)

The fringing
of the MZ was way too large even with the
  
  14548   Wed Apr 17 00:50:17 2019 gautamUpdateALSLarge 2kHz peak (and harmonics) in ALS X no moreI looked into this issue today. Initially,
my thinking was that I'd somehow caused
clipping in the beampath somewhere which
 EX_PDHnoise.pdf 
  14549   Wed Apr 17 11:01:49 2019 gautamUpdateALSLarge 2kHz peak (and harmonics) in ALS X no moreEX green stayed locked to XARM length overnight
without a problem. The spectrogram doesn't
show any alarming time varying features around
 EX_PDH_specGram.pdf 
  14550   Wed Apr 17 18:12:06 2019 gautamUpdateVACVac interlock tripped againAfter getting the go ahead from Chub and
Jon, I restored the Vacuum state to "Vacuum
normal", see Attachment #1. Steps:
 Screenshot_from_2019-04-17_18-11-45.pngScreenshot_from_2019-04-17_18-21-30.png 
  14551   Thu Apr 18 22:35:23 2019 gautamUpdateSUSETMY actuator diagnosis [rana, gautam]

Rana did a checkout of my story
  
  14552   Thu Apr 18 23:10:12 2019 gautamUpdateLoss MeasurementX arm misalignedYehonathan wanted to take some measurements
for loss determination. I misaligned the
X arm completely and we installed a PD on
  
  14554   Fri Apr 19 11:36:23 2019 gautamUpdateSUSNo consistent solution for output matrixTher isn't a consistent set of OSEM
coil gains that explains the best actuation
vectors we determined yesterday. Here are
  
  14556   Fri Apr 19 14:06:36 2019 gautamUpdatePSLInnolight NPRO shutoffWhen I got back from lunch just now, I
noticed that the PMC TRANS and REFL cameras
were showing no spots. I
 Screenshot_from_2019-04-19_14-06-11.png 
  14558   Fri Apr 19 16:19:42 2019 gautamUpdateSUSActuation matrix still not orthogonalI repeated the exercise from yesterday,
this time driving the butterfly mode [+1
-1 -1 +1] and adding the tuned PIT and
  
  14560   Fri Apr 19 20:21:52 2019 gautamUpdatePSLInnolight NPRO shutoffHappened again at ~730pm.

The NPRO diag channels don't
really tell me what happened in a causal
 Screenshot_from_2019-04-19_20-27-04.png 
ELOG V3.1.3-