Entry  Fri Aug 15 17:24:44 2014, Harry, Update, General, Fiber Temp. 
Entry  Wed Aug 13 17:37:43 2014, Jenne, Update, General, Game plan 2014_Aug_13.pdf
    Reply  Thu Aug 14 02:51:46 2014, Jenne, Update, General, Game plan Y_ALS_FINE_PHASE_OUT_noisy_13Aug2014.pdf
    Reply  Thu Aug 14 14:58:03 2014, Jenne, Update, General, Updated game plan 2014_Aug_14.pdf
       Reply  Thu Aug 14 15:42:29 2014, Koji, Update, General, Updated game plan 
          Reply  Thu Aug 14 15:51:37 2014, Jenne, Update, General, Updated game plan 
             Reply  Thu Aug 14 18:02:11 2014, Koji, Update, General, Updated game plan 
                Reply  Thu Aug 14 18:05:05 2014, Jenne, Update, General, Updated game plan 
    Reply  Fri Aug 15 20:26:37 2014, ericq, Update, General, Game plan 
Entry  Mon Aug 18 09:42:50 2014, Koji, Summary, IOO, MCREFL PD charcterization MCREFLPD_transimpedance.pdfMCREFLPD_transimpedance_zoom.pdf
Entry  Tue Aug 19 21:40:44 2014, Andres, Update, IMC, New Optical Setup for the IMC 11x
Entry  Wed Aug 20 15:31:27 2014, ericq, Update, COC, Arm Loss Investigations Continue 
Entry  Mon Aug 18 18:33:57 2014, ericq, Update, Green Locking, Yarm Green PDH yLoop.pdfcrap.pdf
    Reply  Tue Aug 19 01:01:36 2014, Jenne, Rana, Update, Green Locking, Yarm Green PDH YPDH_OLG.pdfYPDH_noise.pdf
       Reply  Tue Aug 19 18:32:40 2014, ericq, Update, Green Locking, Yarm Green PDH 
       Reply  Tue Aug 19 23:11:15 2014, Jenne, Update, Green Locking, Yarm Green PDH ErrAndCtrlSpectra_VoltsPerRtHz.png
       Reply  Wed Aug 20 02:38:41 2014, Jenne, Update, Green Locking, Yarm Green PDH - requirement NoiseConsideration.pdf
          Reply  Wed Aug 20 18:05:18 2014, Jenne, Update, Green Locking, Yarm Green PDH - requirement YPDH_noise.pdf
       Reply  Wed Aug 20 04:09:21 2014, ericq, Update, Green Locking, Xarm Green PDH Xbodes.pdfXspectra.pdfscopeSweep.jpg
          Reply  Wed Aug 20 16:10:43 2014, ericq, Update, Green Locking, Xarm Green PDH XspectraCombined.pdf
             Reply  Wed Aug 20 21:09:16 2014, ericq, Update, Green Locking, Xarm Green PDH scopeSweep.jpgXspectra.pdfYspectra.pdfXYcomp.pdf
Entry  Thu Aug 21 22:10:52 2014, rana, Summary, Computer Scripts / Programs, network movements 
Entry  Fri Aug 22 03:55:45 2014, Jenne, Update, LSC, Xarm PDH fine, Yarm PDH/ALS needs work Xend_ErrorPointMeasurements.pdfDARM_ALSdiff_vs_sqrtInv.pdf
Entry  Fri Aug 22 13:51:00 2014, Jenne, Update, General, Updated game plan 40mToDoList.pdf
Entry  Fri Aug 22 15:11:55 2014, andres, nicolas, Summary, IOO, MC WFS activity 
    Reply  Fri Aug 22 15:58:02 2014, Steve, Summary, IOO, MC WFS activity GoyphaseSet.png
Entry  Fri Aug 22 18:00:08 2014, jamie, Omnistructure, CDS, ubuntu12 awgstream installed 
Entry  Mon Aug 25 15:49:44 2014, Steve, Update, PSL, HEPA turned on 
Entry  Thu Aug 21 02:42:17 2014, rana, ericq, Configuration, Green Locking, Gain changes on Green Y PDH TEK00002.PNGTEK00003.PNG
    Reply  Thu Aug 21 19:04:52 2014, ericq, Configuration, Green Locking, Gain changes on Green Y PDH TEK00005.PNG
       Reply  Tue Aug 26 23:16:49 2014, ericq, Configuration, Green Locking, Gain changes on Green Y PDH Ytfs.pdfpdhComparison.pdfnewY.zip
Entry  Fri Aug 22 18:05:02 2014, Andres, Update, IMC, Upgrade of the IMC WFSs for the reflection ModeCleanerUpgrade.PNG
    Reply  Mon Aug 25 09:56:21 2014, Steve, Update, IMC, IMC WFSs upgrade eq6Mnapa.png
    Reply  Tue Aug 26 23:46:55 2014, ericq, Update, IMC, WFS tuneup newWFSmatrix.pdf
       Reply  Wed Aug 27 09:12:47 2014, Koji, Update, IMC, WFS tuneup 
Entry  Thu Aug 28 01:41:03 2014, ericq, Update, LSC, Phase Tracker UGF normalization UGFnorm.png
Entry  Thu Aug 28 08:31:16 2014, Steve, Update, General, one good day 1goodDay.png1gooday.png
Entry  Thu Aug 28 11:02:53 2014, Steve, Update, Calibration-Repair, SR785 repair 08281401.PDF
Entry  Tue Sep 2 16:22:24 2014, Jenne, Update, General, Game plan: 2 Sept 40mToDoList.pdf
Entry  Tue Sep 2 22:54:27 2014, Koji, Summary, LSC, phase tracker UGF 
Entry  Wed Sep 3 04:17:21 2014, Jenne, Update, LSC, Y green ALS (not PDH) needs investigation Yarm_noisy_above_20Hz.pdf
Entry  Thu Dec 19 21:16:16 2013, Koji, Configuration, General, netgpibdata is working again now 
    Reply  Fri Dec 20 10:08:43 2013, Jamie, Configuration, General, netgpibdata is working again now 
    Reply  Mon Apr 21 22:32:33 2014, rana, Configuration, General, netgpibdata is working again now 
       Reply  Thu Apr 24 22:39:14 2014, rana, Configuration, General, netgpibdata is working again now out.pdf
          Reply  Tue Apr 29 10:01:25 2014, Koji, Configuration, General, netgpibdata is working again now 
    Reply  Wed Sep 3 14:07:18 2014, rana, Configuration, General, netgpibdata is working again now 
Entry  Thu Sep 4 01:28:32 2014, ericq, Update, LSC, Recycling cavity lengths 
    Reply  Thu Sep 4 10:10:23 2014, Koji, Update, LSC, Recycling cavity lengths 
       Reply  Thu Sep 4 18:16:20 2014, ericq, Update, LSC, Recycling cavity lengths 2014-09-CavityLengths.zip
Entry  Thu Sep 4 18:30:13 2014, Gabriele, Summary, ASC, Optimal Gouy phase for POP QPD pop_qpd_dc.pngfortymeters.mistfortymeters_pop_qpd.mistpop_qpd.m
Entry  Fri Sep 5 00:56:00 2014, rana, Summary, Optical Levers, ITM OLs recentered: violations found 
Entry  Fri Sep 5 03:36:00 2014, rana, Update, Computer Scripts / Programs, martian wireless tweak 
Entry  Wed Sep 3 18:42:43 2014, Jenne, Update, LSC, Green PDH box boosts BoostCartoon.pdf
    Reply  Thu Sep 4 00:56:44 2014, Jenne, Update, LSC, Green PDH box boosts TFstage_newDesign_3Sept2014.pngBoostNoBoost_newDesign_3Sept2014.pngBoostOnly_newDesign_3Sept2014.pngD0901351-v1_3Sept2014.pdf
       Reply  Thu Sep 4 03:12:55 2014, ericq, Update, LSC, Green PDH box boosts boostedTF.pdfgain.jpg
       Reply  Thu Sep 4 16:45:10 2014, Jenne, Update, LSC, Green PDH box boosts IMG_1712.JPGIMG_1714.JPG
          Reply  Fri Sep 5 05:32:57 2014, Jenne, Update, LSC, Green PDH box boosts TRX_TRY_ALSvsIR_4Sept2014.pdf
             Reply  Fri Sep 5 21:13:57 2014, Jenne, Update, LSC, Green PDH out of loop ALS_XY_outOfLoop_5Sept2014.pdf
Entry  Mon Sep 8 07:50:40 2014, Steve, Update, SUS, PRM damping restored 
Entry  Wed Aug 27 18:03:47 2014, ericq, Update, Green Locking, uPDH Box Checkup uPDH_X.JPGuPDH_Y.JPGupdhTFs.pdfupdhNoises.pdfuPDH_Aug27.zip
    Reply  Thu Aug 28 17:34:20 2014, ericq, Update, Green Locking, uPDH Box Checkup TEK00006.PNG
       Reply  Fri Aug 29 17:28:07 2014, rana, Update, Green Locking, uPDH Box Checkup 
          Reply  Fri Aug 29 23:53:35 2014, ericq, Update, Green Locking, uPDH Box Checkup 
             Reply  Tue Sep 2 20:02:06 2014, ericq, Update, Green Locking, uPDH Box Checkup 
       Reply  Wed Sep 3 00:17:22 2014, rana, Update, Green Locking, uPDH Box Checkup 
          Reply  Wed Sep 3 20:38:40 2014, ericq, Update, Green Locking, uPDH Box Checkup 
             Reply  Fri Sep 5 04:07:44 2014, ericq, Update, Green Locking, X end uPDH Box Replaced 
                Reply  Fri Sep 5 16:13:00 2014, ericq, Update, Green Locking, new X Green PDH measurements 6x
                   Reply  Sat Sep 6 01:48:54 2014, rana, Update, Green Locking, new X Green PDH measurements 
                      Reply  Sat Sep 6 14:49:12 2014, ericq, Update, Green Locking, new X Green PDH measurements xGComparison.pdfxGspectra.pdf
                         Reply  Sun Sep 7 17:06:38 2014, rana, Update, Green Locking, new X Green PDH measurements 
                         Reply  Mon Sep 8 14:14:13 2014, Jenne, Update, Green Locking, new Y Green PDH measurements 6x
Entry  Mon Sep 8 16:23:25 2014, Larry, HowTo, Computer Scripts / Programs, accessing 40m data remotely with python get40mData.ipynb.gz
Entry  Wed Sep 10 02:26:20 2014, Jenne, Update, LSC, DARM -> AS55 optickle AS55Q_vs_DARM_PRFPMI_0pm300pm.pngAS55I_vs_DARM_PRFPMI_0pm300pm.pngAS55Q_vs_DARM_DRFPMI_0pm300pm.pngAS55I_vs_DARM_DRFPMI_0pm300pm.pngAS55Q_vs_DARM_DRFPMI_0pm1000pm.png
Entry  Wed Sep 10 02:35:54 2014, Jenne, HowTo, Treasure, Secret scripts, revealed! 
Entry  Tue Sep 9 23:05:01 2014, Koji, Update, CDS, OTTAVIA lost network connection 
    Reply  Wed Sep 10 02:35:55 2014, rana, Update, CDS, OTTAVIA lost network connection 
       Reply  Wed Sep 10 02:52:05 2014, ericq, Update, CDS, OTTAVIA lost network connection 
Entry  Wed Sep 10 02:53:32 2014, Jenne, Update, LSC, Locking activities - nothing new :( LocklossZoom.png
    Reply  Wed Sep 10 02:59:42 2014, ericq, Update, LSC, Locking activities - nothing new :( 
Entry  Wed Sep 10 20:24:00 2014, Jenne, Update, Electronics, POY RF cable loose 
Entry  Thu Sep 11 00:27:39 2014, Jenne, Update, SUS, SRM oplev touch-up 
Entry  Thu Sep 11 02:08:32 2014, Jenne, Update, LSC, Higher transmission powers Zoom_TRXTRYat7_CARMsqrtInvTrans_DARMalsdiff.pngALSonly_TryingTransitionStraightToREFLDC.png
Entry  Thu Sep 11 15:50:49 2014, Steve, Update, SUS, ETMX damping restored 
Entry  Tue Sep 9 00:34:34 2014, Jenne, Update, LSC, Figuring out where to do DARM->AS55 
    Reply  Tue Sep 9 14:25:46 2014, jamie, Update, LSC, Figuring out where to do DARM->AS55 
    Reply  Wed Sep 10 10:49:39 2014, Manasa, Update, LSC, Y arm green + PSL green mode overlap 
       Reply  Wed Sep 10 21:05:43 2014, Jenne, Update, LSC, Holy sensitivity, Batman! ALS_Y_outOfLoop_10Sept2014.pdfALS_XY_outOfLoop_10Sept2014.pdf
          Reply  Fri Sep 12 00:28:04 2014, ericq, Update, LSC, Holy sensitivity, Batman! ALSoutOfLoop.pdf
Entry  Fri Sep 12 03:49:57 2014, ericq, Update, LSC, Some more PRFPMI efforts 
Entry  Fri Sep 12 15:10:09 2014, Jenne, Update, ASC, MICH ASS 
Entry  Mon Sep 15 15:52:44 2014, Steve, Update, SUS, PRM damping restored 
Entry  Tue Sep 16 10:47:52 2014, Steve, Update, PSL, Laser turned on 
    Reply  Tue Sep 16 14:26:45 2014, ericq, Update, PSL, Laser turned on 
    Reply  Tue Sep 16 16:03:36 2014, Koji, Update, PSL, Laser turned on 
Entry  Mon Sep 8 08:24:49 2014, Steve, Update, Computer Scripts / Programs, preparing vac system to reboot 
    Reply  Mon Sep 8 11:10:26 2014, ericq, Update, Computer Scripts / Programs, preparing vac system to reboot 
       Reply  Mon Sep 8 11:34:47 2014, rana, Update, Computer Scripts / Programs, preparing vac system to reboot 
          Reply  Mon Sep 8 12:11:36 2014, manasa, Update, Computer Scripts / Programs, preparing vac system to reboot 
             Reply  Mon Sep 8 15:50:47 2014, ericq, Update, Computer Scripts / Programs, +15V PSL Sorensen replaced 
       Reply  Tue Sep 9 09:19:21 2014, Steve, Update, safety, response to fried Sorensen friedSorenson.pngsmokeAlarm1a.jpgsmokeAlarm2a.jpg
       Reply  Tue Sep 9 14:18:40 2014, Steve, Update, Computer Scripts / Programs, preparing vac system to reboot v1closedfor1h.png
       Reply  Tue Sep 16 17:02:41 2014, Steve, Update, Computer Scripts / Programs, PSL output shutter is floating 
Entry  Wed Sep 17 01:40:55 2014, Jenne, Update, LSC, Closer to REFL DC? Maybe? Zoom_TRXTRYupto25_1094967592.png
Entry  Wed Sep 17 18:36:03 2014, Koji, HowTo, General, How to run DTT measurement automatically 
Entry  Tue Sep 23 09:37:12 2014, Steve, Update, SUS, IOO and temp changes IOO.png
Entry  Tue Sep 23 17:56:13 2014, Jenne, EricQ, Update, General, Vent prep for SRC length change 
    Reply  Wed Sep 24 08:39:32 2014, Jenne, EricQ, Update, General, Vent prep for SRC length change 
       Reply  Wed Sep 24 08:40:29 2014, Steve, Update, VAC, Vent has started vent77.pngbvent77.png
Entry  Wed Sep 24 18:56:45 2014, ericq, Update, General, Ottavia slowness 
Entry  Fri Sep 12 00:40:23 2014, Jenne, Update, LSC, DRMI locking 
    Reply  Fri Sep 12 11:25:42 2014, Koji, Update, LSC, DRMI locking 
       Reply  Fri Sep 12 12:00:59 2014, ericq, Update, LSC, DRMI locking 
    Reply  Fri Sep 12 14:11:17 2014, ericq, Update, LSC, DRMI locking 7x
       Reply  Wed Sep 17 15:40:00 2014, ericq, Update, LSC, DRMI locking dcAngleDiff_srcL.pdfdrfpmiVertexSensing.zip
          Reply  Tue Sep 23 17:37:10 2014, ericq, Update, LSC, DRMI locking SRCcorrection.pdf
             Reply  Wed Sep 24 11:02:38 2014, manasa, Update, LSC, Moving SRM 
                Reply  Thu Sep 25 11:33:41 2014, Jenne, Update, LSC, POY alignment laser 
Entry  Mon Jun 16 21:22:16 2014, Jenne, Update, Computer Scripts / Programs, Rossa having a bad day 
    Reply  Wed Jun 18 19:30:28 2014, Jenne, Update, Computer Scripts / Programs, Rossa having a better day 
       Reply  Thu Sep 25 15:41:15 2014, ericq, Update, Computer Scripts / Programs, Rossa having a better day 
ELOG V3.1.3-