40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 124 of 339  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  6195   Fri Jan 13 00:51:40 2012 Leo SingerUpdateStewart platformFrequency-dependent requirements for Stewart platformBelow are revised design parameters for
the Stewart platform based on ground motion
measurements.
 ground_velocity_spectrum.pngrequirements.png 
  6196   Fri Jan 13 16:16:05 2012 Leo SingerUpdateStewart platformFlexure type for leg jointsI had been thinking of using this
flexure for the bearings for the
leg joints, but I finally realized that it
  
  6197   Fri Jan 13 17:40:38 2012 ZachUpdateRF Systemfoam box and temp controller taken off of PSL tableI stole the foam EOM box and the temperature
controller circuit from the PSL table so
that I could continue with the RAM measurements
  
  6198   Sat Jan 14 00:50:08 2012 rana, kojiConfigurationIOOTowards coating thermal noise measurement with RefCav / MC beatKoji asked aloud tonight if we could   
  6199   Sun Jan 15 10:28:02 2012 DenUpdateAdaptive FilteringdelaysWe can account for delays in the oaf system
by compensating it in the adaptive path of
the filter. But using only this procedure
 2048_tau.png2048_delays.png 
  6200   Sun Jan 15 11:40:30 2012 DenUpdateAdaptive FilteringdownsamplingHere for the downsampling process we use
a low-pass Bessel digital filter of order
6, normalized cut-off frequency = 0.1. In
 2048_downsampling.png2048_512.png 
  6201   Sun Jan 15 12:18:00 2012 DenUpdateAdaptive Filteringrunning time In order to figure out what downsampling
ratio we can take, we need to determine the
running time of the fxlms_filter() function.
  
  6202   Tue Jan 17 01:02:07 2012 kiwamuUpdateLSCglitch hunting in REFL RFPDs : strangeA very
strange thing is going on.
 PRMsingle_bounce.png 
  6203   Tue Jan 17 02:27:49 2012 kiwamuUpdateLSCfringe tests : all the suspensions are innocentI did a quick test to check a hypothesis
that PRM is interfering with some other optics
in the single bounce configuration.
  
  6204   Tue Jan 17 02:44:59 2012 kiwamuUpdateCDSawg not workingAWG
is not working. This needs to be fixed.
  
  6205   Tue Jan 17 03:10:27 2012 kiwamuConfigurationIOOrotated lambda/2 plate I have slightly rotated the lambda/2 plate,
which is used for attenuating the REFL beam's
power on the AS table
  
  6206   Tue Jan 17 13:47:40 2012 kiwamuUpdateLSCdirty steering mirror in the REFL path Last
night I found that there were many dust particles
on the second steering mirror in the REFL
  
  6207   Tue Jan 17 16:09:20 2012 kiwamuUpdateCDSawg not working on the c1sus machineActually awg works fine without any
problems when the excitation channels belong
to the c1lsc machine.
  
  6208   Tue Jan 17 19:07:47 2012 ranaUpdateLSCglitch hunting in REFL RFPDs : strange Another possibility is that there
is some beam clipping of the REFL beam before
it gets to the PD. Then there could be a
  
  6209   Wed Jan 18 12:36:26 2012 kiwamuUpdateLSCwiped a steering mirror on the REFL pathI
wiped both surfaces of the REFL second steering
mirror.
 DSC_3861_small.jpgDSC_3863_small.jpg 
  6210   Wed Jan 18 12:38:44 2012 steveUpdatePEMAcrylic plexiglass transmittance   Acrylite-Gp.pptxroscogel_red#26_film.pdf 
  6211   Wed Jan 18 14:28:36 2012 kiwamuUpdateLSCestimation of optical length between PRM and scattering objectAssuming
that PRM is interfering with some other optics,
I have estimated the optical distance between
 calibration.pngscattering.png 
  6212   Wed Jan 18 16:31:10 2012 kiwamuUpdateLSCestimation of optical length between PRM and scattering objectI
searched for a scattering body in the REFL
path.
 ND1atten.png 
  6213   Thu Jan 19 23:34:52 2012 kiwamuUpdateIOOPMC realignment and HEPAI realigned the incident beam to PMC at
23:30. The transmitted light went up from
0.78 to 0.83.
  
  6214   Fri Jan 20 15:59:02 2012 kiwamuUpdateGreen LockingY arm ALS noige budgetOne of
my goals in this week is : measurement of
 Yarm_ALS_2012Jan19.png 
  6215   Fri Jan 20 16:24:50 2012 kiwamuUpdateGreen LockingY arm ALS : time seriesHere is
a new time series plot showing how stably
 time_series.png 
  6216   Fri Jan 20 17:05:59 2012 ranaUpdateGreen LockingY arm ALS : time series      
           
  
  6217   Mon Jan 23 15:43:47 2012 JenneUpdateIOOPMC realignment

    
        
  
  6218   Mon Jan 23 23:12:00 2012 kiwamuUpdateIOOPMC realignmentI have realigned the beam pointing to PMC.
The transmitted light increased from 0.74
to 0.83.
  
  6219   Tue Jan 24 13:36:05 2012 ZachBureaucracyGeneralIf I'm Peter Pan...   jamie_rufio.png 
  6220   Tue Jan 24 18:11:13 2012 kiwamuUpdateGreen LockingY arm ALS noise budgetI
did some more stuff for the Y arm ALS and
updated the noise budget:
 Yarm_ALS_2012Jan19.pngnewservo.png 
  6221   Wed Jan 25 02:59:46 2012 kiwamuUpdateGreen LockingY arm ALS noise budgetSurprisingly
increasing the gain of the whitening filter
didn't improve the noise curve.
  
  6222   Wed Jan 25 15:04:41 2012 JenneBureaucracySAFETY40m SOS supplies moved off of cleanroom flow benchBob, Callum and Daphen noted that our keeping
a JDSU HeNe (max power <4mW) is against
somebody's SOP.  So I cleared everything
  
  6223   Wed Jan 25 17:32:03 2012 steveUpdateGreen Lockinggeen pointing into y arm is misalignedI  placed an other Y2-LW-1-2050-UV-45P/AR
steering mirror into the beam path of the
green beam launching in order to avoid the
  
  6224   Thu Jan 26 05:40:10 2012 kiwamuUpdateLSCglitch in the analog demodulated signalsIndeed
the glitches show up in the analog demodulated
signals. So it is not an issue of the digital
 glitch.png 
  6225   Thu Jan 26 06:09:52 2012 kiwamuUpdateGreen Lockingnoisy AS55During
the Y arm ALS I found that the noise of the
AS55 demod signal was worse than that of
 Yarm_ALS_2012Jan25.png 
  6226   Thu Jan 26 08:36:38 2012 steveUpdateSAFETYevacuation drillIt started with fire alarm test yesterday
at 14:50 All alarms are  functioning
VERY loud and their flashers are bright.
  
  6227   Thu Jan 26 10:17:01 2012 steveUpdateGreen Lockinggeen pointing into y arm is realigned

    

       
            
 P1080513.JPG 
  6228   Thu Jan 26 15:35:23 2012 JenneUpdateIOOMC ~1Hz badnessThe mode cleaner is super unhappy. 
It's rocking around at ~1Hz.
I turned off the WFS and turned them
  
  6229   Thu Jan 26 19:28:02 2012 kiwamuUpdateIOOPMC low transmissionAfter I recovered the lock of PMC, I found
that the PMC transmission was quite low.
It was about 0.26 in the EPICS display.
  
  6230   Fri Jan 27 05:21:43 2012 kiwamuUpdateGreen Lockingfine alignment of the Y end green setupI did a fine alignment on the Y end green
setup. The green light became able to be
locked again.
  
  6231   Fri Jan 27 06:07:47 2012 kiwamuUpdateLSCglitch huntingI went through various
IFO configurations to see if there are glitches
  
  6232   Fri Jan 27 09:05:41 2012 steveUpdateSUSOSEM locking plunger

    

       
            
  
  6233   Fri Jan 27 13:13:03 2012 JenneUpdateSUSITMs trippedSitting down to start cavity measurements,
I found both ITMs tripped.  It must
have happened a while ago (I didn't bother
  
  6234   Fri Jan 27 16:55:28 2012 JenneUpdateGreen LockingY-green realignedThe Yarm green laser really wanted to lock
on a 01/10 mode, so Kiwamu suggested I go
inside and realign the green beam to the
  
  6235   Fri Jan 27 17:16:05 2012 kiwamuUpdateLSChypothetical glitch scenarioHere is a hypothetical scenario which
could make the glitches in the LSC error
signals. It can be considered as a
  
  6236   Mon Jan 30 08:17:06 2012 steveUpdateIOOPMC


   
        
            
 sickPMC.png 
  6237   Mon Jan 30 16:18:51 2012 steveUpdatePEMRoscolux colored film transmittance at 1064 nm 
 Roscolux filter films 
#74 night blue,  0.003" thick 
  
  6238   Mon Jan 30 23:10:02 2012 kiwamuUpdateSUSdrift mon script needs to be fixed[Rana / Kiwamu]
We tried to set some parameters for
the suspension drift monitor but the old
  
  6239   Tue Jan 31 08:44:10 2012 steveUpdateIOOlaser shuts down 
 The 2W Innilight shutdown shut
when I opened side door for safety scan.
 laseroff.png 
  6240   Tue Jan 31 14:58:30 2012 kiwamuUpdateIOOlaser shuts down[Steve/ Kiwamu]   
 We found that the laser had
completely shut off for ~ 4 hours even with
  
  6241   Tue Jan 31 17:13:49 2012 steveUpdateIOOonly the PSL laser is off 
The 2W PSL laser is turned off. 
  
  6242   Wed Feb 1 17:00:57 2012 steveUpdateIOOlaser is back ON

    

       
            
 P1080525.JPGP1080514.JPGP1080518.JPG 
  6243   Fri Feb 3 10:48:24 2012 DenUpdateComputersc1lsc kernelThis morning I killed again c1lsc kernel
with the new realization of fxlms algorithm.
It works fine with gcc compiler during the
  
  6244   Fri Feb 3 14:44:33 2012 JenneUpdateIOOMC SUS misalignmentThe mode cleaner is a little misaligned
in pitch, and is very misaligned in yaw. 
The lowest order mode that is flashing is
 SUSjump_3Feb2012.png 
ELOG V3.1.3-