40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 122 of 335  Not logged in ELOG logo
ID Date Author Type Category Subject Text Attachments
  10742   Mon Dec 1 17:19:22 2014 JenneUpdateGeneralPMC align[Diego, Jenne]
Tweaked up the input alignment to
the PMC.  Now we're at 0.785.
  
  10741   Mon Dec 1 17:13:57 2014 SteveUpdateVACRGA scan pd78 -day 63

    

       
            
 RGAscanD63.png 
  10740   Mon Dec 1 16:34:20 2014 JenneUpdateGeneralIFO wake-up 
 After its' several days of
rest, it is time to wake up the IFO. 
  
  10739   Mon Dec 1 15:41:38 2014 SteveUpdateGeneralX end fiber insulated and on cable tray


   
        
            
  
  10738   Mon Dec 1 07:30:29 2014 SteveUpdateSUSETMX damping restoredETMX sus damping restored and PMC locked
manually.
  
  10737   Wed Nov 26 22:24:28 2014 JenneUpdateLSCDARM loop improved, other work[Jenne, Koji]
We have done several things this
evening, which have incrementally helped
 8x 
  10736   Wed Nov 26 05:15:48 2014 JenneUpdateLSCPRFPMI tonight PRMI 100Hz osc?[Jenne, EricQ]
Just to get our day started right,
we tweaked up the alignment of the Ygreen
 PRFPMI_currentErrSigs_25Nov2014.pdf 
  10735   Tue Nov 25 14:52:14 2014 ericqUpdateOptical LeversOpLev RINs At Rana's request, I've made an in-situ
measurement of the RIN of all of our OpLevs.
PSL shutter closed, 10mHz BW. The OpLevs
 RIN.pdf 
  10734   Tue Nov 25 02:04:19 2014 JenneUpdateLSCPRFPMI tonight - need some PRCL and MICH tuning at high arm powersTake-away for the night:  We need
to do some more fine-tuning of the PRCL and
MICH loops when we have arm resonance.
 HighPower_7pt3sec_Powers.pngHighPower_7pt3sec_ErrAndCtrls.pngHighPower_7pt3sec_AuxErrs.pngCARMDARMonALScommdiff_StayingAbove5_upTo175_24Nov2014.png 
  10733   Mon Nov 24 20:24:29 2014 diegoUpdateSUSAnti-Jitter Telescope for OpLevsI stared a bit longer at the plots and
thanks to Eric's feedback I noticed I payed
too much attention to the comparison between
 6x 
  10732   Fri Nov 21 18:23:01 2014 diegoUpdateSUSAnti-Jitter Telescope for OpLevsEDIT: some images look
bad on the elog, and the notebook is parsed,
 14x 
  10731   Fri Nov 21 13:58:51 2014 ericqUpdateOptical LeversHeNe RIN test Steve had me measure the RIN of a
JDSU HeNe laser. I used a PDA520, and measured
the RIN after the laser had been running
 2014-11-21_HeNeRIN.zipRIN_P893519.pdf 
  10730   Fri Nov 21 11:41:24 2014 manasaUpdateGeneralX end fiber insulated and on cable tray

    

       
            
  
  10729   Fri Nov 21 02:22:25 2014 ericqUpdateLSCMore ALS PRFPMI exploration Similar to what Jenne did the other
night, I kept the PRFPMI arm DoFs locked
on ALS, in hopes to check out the RF error
  
  10728   Thu Nov 20 22:43:15 2014 KojiUpdateIOOIMC WFS damping gain adjustmentFrom the measured OLTF, the dynamics of
the damped suspension was inferred by calculating
H_damped = H_pend / (1+OLTF).
 MC_OLTF_CLTF.pdf 
  10727   Tue Nov 18 22:34:28 2014 JenneUpdateLSCSome other plots from PRFPMI


   
        
            
 TRXmax98_TRYmax107_CARMdarmOnALS_0carmOffset.pngZoom_with_POP22.pngZoom_with_POP110.pngZoom_with_ErrSigs.png 
  10726   Tue Nov 18 17:11:30 2014 JenneUpdateLSCSome lockloss plots from PRFPMII am still staring at / trying to figure
out the latter 4 locklosses posted earlier. 
But, I have just included the transmission
  
  10725   Tue Nov 18 15:20:58 2014 JenneUpdateLSCSome lockloss plots from PRFPMIElog from ~5am last night:
Tonight was just several trials
of PRFPMI locking, while trying to pay more
 8x 
  10724   Mon Nov 17 23:04:51 2014 JenneUpdatePSLAligned PMCI aligned the beam into the PMC, mostly
in yaw.  Don't know why it drifted,
but it was annoying me, so I fixed it.
  
  10723   Mon Nov 17 20:40:29 2014 rana, diegoUpdateIOOInvestigating the IMC WFS situationWe've known for years that the IMC WFS
sensing chain is pointlessly bad, but until
recently, we haven't thought it was worth
  
  10722   Mon Nov 17 20:28:17 2014 ranaSummaryIOOMC servo summing ampI modified the /cvs/cds/caltech/target/c1psl/psl.db
file to adjust the records for the FSS-FAST
signal (to make it go yellow / red at the
  
  10721   Sat Nov 15 21:51:09 2014 ranaUpdatePEMSeismometers set up for huddle test  In order to do high quality
huddle subtraction, we need to align the
seismometer axes to high precision. We would
  
  10720   Fri Nov 14 20:31:13 2014 ericqUpdateLSCRIN in transmission a problem?I took a quick look at single arm RIN.
Actuating on MC2 vs. the ETM, or using AS55
instead of POY11 made no noticeable difference
  
  10719   Fri Nov 14 19:28:33 2014 JenneUpdateSUSASS gain reduced for Yarm[Koji, Jenne]
We noticed last night that the yarm
couldn't handle the old nominal gain for
  
  10718   Fri Nov 14 17:08:17 2014 JenneUpdateLSCRIN vs. SeismicT-240 has a different convention than we
use.  It assumes that North is aligned
with the Y-axis.  Since this is the
  
  10717   Fri Nov 14 15:45:34 2014 JenneUpdateCDSComputers back up after reboot[Jenne, Q]
Everything
  
  10716   Fri Nov 14 15:26:45 2014 SteveUpdatesafetyDiego gets safety traningDiego Bersanetti received 40m specific
safety training today.
  
  10715   Fri Nov 14 11:07:59 2014 manasaUpdateCDSNot able to run models on FE machines

    

       
            
 CDSissue.png 
  10714   Fri Nov 14 08:25:29 2014 SteveUpdateSUSmorning issuesPRM, SRM and the ENDs are kicking up. 
Computers are down.  PMC slider is stuck
at low voltage.
 morning.png 
  10713   Fri Nov 14 02:43:05 2014 ericqUpdateLSCPRFPMI HOM resonancesI've extended my analysis to the PRFPMI
case, with the current working knowledge
of radii of curvature and cavity lengths.
 HOMcurves.pdfHOMpeaks.pdfprfpmiHOM.zip 
  10712   Thu Nov 13 23:42:01 2014 JenneUpdateLSCRIN vs. SeismicAfter Kate, Diego and I moved the seismometers
to the corner for a huddle test (see elog
10711), I wanted to check the coherence
 Seismic_TRXTRYandMC_13Nov2014.pdf 
  10711   Thu Nov 13 22:52:48 2014 kateUpdatePEMSeismometers set up for huddle testJenne, Diego, Kate
We want to conduct a huddle test
with the three 40m seismometers (2 Guralps
 Seismic_13Nov2014.pdfseism_closed.jpgseism_open.jpg 
  10709   Thu Nov 13 04:28:28 2014 JenneUpdateLSCRIN in transmission a problem?[Jenne, Rana, Koji]
We
did some thinking on what could be causing
 zippyzip.zipRIN_TRX_TRY_IPPOS_NoLens_12Nov2014.pdf 
  10708   Thu Nov 13 01:03:28 2014 rana, jenneUpdateSUSOL updates on ITMs and ETMs We copied the new SRM filters over
onto the OL banks for the ITMs and ETMs.
We then adjusted the gain to be 3x lower
  
  10707   Thu Nov 13 01:00:37 2014 ranaUpdateLSCRIN in transmission a problem? 
 I modified the MC2 trans optical
setup a little bit: the reflection from the
  
  10706   Wed Nov 12 22:22:11 2014 KojiSummaryIOOEstimation of the angular jitter imposed by the TTs[Koji, Rana, Jenne]
One coil of the TT produce 36nrad/rtHz
at DC.
 03.png 
  10705   Wed Nov 12 21:18:32 2014 ericqUpdateLSCDRFPMI, PRFPMI HOM resonancesSo, with my last entry, I was guilty of
just throwing stuff into the simulation and
not thinking about physics... so I retreated
 HOMlist.py.zip 
  10704   Wed Nov 12 20:11:41 2014 KojiUpdateIOOMC WFS gain reduced againMC WFS was oscillative at 1Hz. I've reduced
the servo gain further (x1, x1, x10, x1,
x1, and x10).
  
  10703   Wed Nov 12 18:08:35 2014 JenneUpdateLSCRIN in transmission a problem?In my previous meditations about RIN, particularly
elog
10258, I was only thinking about the
 RIN_TRX_TRY_MCtrans_12Nov2014_zip.xml.gzRIN_TRX_TRY_MCtrans_12Nov2014.pdfRINcontribution_12Nov2014_linearXscale.pngRINcontribution_12NOv2014_logXscale.png 
  10702   Wed Nov 12 15:14:09 2014 manasaUpdateGeneralX end AUX laser fiber setup I looked at the endtable for possible
space to setup optics in order to couple
the X end laser into a PM fiber.
 ETMXtable.png 
  10701   Wed Nov 12 03:22:23 2014 JenneUpdateLSC3f DRMI sensing matKoji pointed out something to me that I
think he had told me ages ago, and Rana alluded
to last night:  Since I'm not tuning
 8x 
  10700   Wed Nov 12 01:30:39 2014 ericqUpdateLSCDRFPMI, PRFPMI HOM resonancesI did some simulations to see if we are
susceptible to HOM resonances as we reduce
the CARM offset. I restricted my search to
 HOMs.zipDRFPMI_HOMscan.pngPRFPMI_HOMscan.png 
  10699   Wed Nov 12 00:55:56 2014 ericqUpdateLSCNotch at 110MHz

    

       
            
 165_Notched.pdf 
  10698   Tue Nov 11 21:41:09 2014 KojiUpdateLSC3f DRMI sensing matSensing
matrix calculation using DTT + Matlab
Note: If the signal phase is, for
 DRMI_radar.pdf 
  10697   Tue Nov 11 19:46:35 2014 diegoUpdateComputer Scripts / ProgramsStatus of the new nodusThe new nodus machine is being brought
to life; until installation is finished and
everything is fine, the old nodus will be
  
  10696   Tue Nov 11 03:48:46 2014 JenneUpdateLSC3f DRMII was
able to lock the DRMI on 3f signals this
evening, although the loops are not stable,
 SensMatMeas_10Nov2014_DRMI.pngSensMatMeas_10Nov2014_PRMI.png 
  10695   Tue Nov 11 01:38:23 2014 KojiUpdateLSCNotch at 110MHzTo further reduce the RF power at 110MHz
in the REFL165 chain, I made a twin-t notch
in a pomona box.
 twin_t_notch.pdfnotch_tf.pdf 
  10694   Mon Nov 10 23:14:20 2014 ranaSummarySUSSRM: damping gains & Optical Lever servo Tune-up
     tweaked gains for POS,
PIT, YAW, SIDE by ~10-20% to get nice ringdowns
with Q~5.
    Measured bounce rool
 SRM-BR.pdfSRM_err_141110.pdfSRM-OLG.pdf 
  10693   Mon Nov 10 18:23:10 2014 ericqConfigurationLSCDRMI sensingARG, I accidentally permuted the digital
demod angles. This significantly weakens
the argument for believing AS55I is broken...
 REFL11.pngREFL33.pngREFL55.pngREFL165.pngAS55.png 
  10692   Mon Nov 10 18:11:57 2014 ericqUpdateLSC3F RFPD RF spectra Jenne and I measured the situation
using a SHP-150 directly attached to the
REFL165 RF output, and at first glance, the
 165signals.pdf 
ELOG V3.1.3-