40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 122 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  16653   Wed Feb 9 13:55:05 2022 KojiUpdateGeneralBringing back CDSGreat recovery work and cleaning of the
rebooting process.

I'm just curious: Did you observe
  
  16656   Thu Feb 10 14:39:31 2022 KojiSummaryComputersNetwork security issue resolved[Mike P / Koji / Tega / Anchal]

IMSS/LIGO IT notified us that "ILOM
ports" of one of our hosts on the "114"
 PXL_20220210_220816955.jpgPXL_20220210_220827167.jpg 
  16659   Thu Feb 10 19:03:23 2022 KojiUpdateGeneralScheduled power outage recovery - Locking mode cleaner(s)I came back to the 40m and started the
investigation.

If I ping 192.168.113.92, it responds.
  
  16660   Thu Feb 10 19:46:37 2022 KojiUpdateGeneralScheduled power outage recovery - Locking mode cleaner(s)==
Assign new IP address to c1sus2 ==

cf: [40m
  
  16661   Thu Feb 10 21:10:43 2022 KojiUpdateGeneralVideo Mux setting resetNow the video matrix is responding correctly
and the web interface shows up. (Attachment
1)
 Screenshot_2022-02-10_21-11-21.pngScreenshot_2022-02-10_21-11-54.png 
  16662   Thu Feb 10 21:16:27 2022 KojiSummaryCDSchiara resolv.conf wierdoDuring the videomux debug, I noticed that
the host name resolving on chiara didn't
behave well. Basically I could not login
  
  16663   Thu Feb 10 21:51:02 2022 KojiUpdateCDS[Solved] Huge random numbers flowing into ETMX/ETMY ASC PIT/YAWHuge random numbers are flowing into ETMX/ETMY
ASC PIT/YAW. Because of this, I could not
damp the ETMX/ETMY suspension at the beginning
 Screenshot_2022-02-10_21-46-02.pngScreen_Shot_2022-02-10_at_21.54.21.pngScreen_Shot_2022-02-10_at_22.14.23.png 
  16671   Mon Feb 14 21:03:25 2022 KojiUpdateGeneralScheduled power outage recoveryI opened the boxes. Allegra has obvious
vent of at least 4 caps. And the power supply
did not respond even a paper clip test was
 PXL_20220215_025325118.jpg 
  16672   Tue Feb 15 19:32:50 2022 KojiUpdateGeneralScheduled power outage recovery - IMC recovery progressReduced the IMC power to 100mW

Setup: The power
meter was placed right before the final aperture
 PXL_20220216_001731377.jpgScreen_Shot_2022-02-15_at_16.18.16.pngPXL_20220216_001727465.jpgScreen_Shot_2022-02-15_at_16.22.16.pngPXL_20220216_002229572.jpg 
  16673   Tue Feb 15 19:40:02 2022 KojiUpdateGeneralIMC lockingIMC
is locking now. There was
nothing wrong: just a careful alignment +
  
  16684   Sat Feb 26 23:48:14 2022 KojiUpdateSUSETMY SUS Electronics Replacement[Ian, Koji] - Activity
on 25th (Fri)

We continued working on
 PXL_20220226_023111179_2.jpg 
  16685   Sun Feb 27 00:37:00 2022 KojiUpdateGeneralIMC Locking RecoverySummary:

- IMC was locked.
- Some alignment change in the output
 PXL_20220226_093809056.jpgPXL_20220226_093854857.jpgPXL_20220226_100859871.jpgScreenshot_2022-02-26_01-56-31.pngScreenshot_2022-02-26_01-56-47.png 
  16686   Sun Feb 27 01:12:46 2022 KojiUpdateGeneralIMC manual alignment procedureWe expect that the MC sus are susceptible
to the temperature change and the alignment
drifts away with time.
 PXL_20220226_100859871.jpg 
  16690   Tue Mar 1 19:26:24 2022 KojiUpdateSUSETMY SUS Electronics ReplacementThe replacement key switches and Ne Indicators
came in. They were replaced and work fine
now.
 PXL_20220302_025723651.jpgPXL_20220302_030102033.MP.jpg 
  16695   Thu Mar 3 04:11:36 2022 KojiUpdateSUSETMY 1Y4 Electronics ReplacementFor the Y-end electronics replacement,
we want to remove unused power supplies.
In fact, we already removed the +/-5V supplies
 PXL_20220303_082726693.jpgPXL_20220303_082752494.jpgPXL_20220303_082744464.jpg 
  16696   Thu Mar 3 04:24:23 2022 KojiUpdateSUSETMY 1Y4 Electronics ReplacementThe DC power strip at Y-end was connected
to the bottom two Sorensen power supplies.
They are configured to provide +/-18V.
 PXL_20220303_094421604.jpgPXL_20220303_094435127.jpg 
  16701   Fri Mar 4 18:12:44 2022 KojiUpdateVACRGA pumping down1. Jordan reported that the newly installed
Pirani gauge for P2 shows 850Torr while PTP2
show 680 Torr. Because of this, the vacuum
 Screenshot_2022-03-04_19-38-11.png 
  16702   Sat Mar 5 01:58:49 2022 KojiSummaryCDSpaola rescueETMY end ThinkPad "paola" could
not reboot due to "Fan Error".
It seems that it is the failure of the CPU
 PXL_20220305_035255834.jpgPXL_20220305_034649120.MP.jpg 
  16703   Sat Mar 5 02:03:46 2022 KojiUpdateSUSETMY 1Y4 Electronics ReplacementOplev saga

Summary 

- The new coil driver had not enough
 6x 
  16707   Mon Mar 7 14:52:34 2022 KojiUpdateVACOngoing work to get the FRG gauges readouts to EPICs channelsGreat trouble shoot!

> I guess, the only remaining
issue now is the incorrect atmospheric
  
  16708   Mon Mar 7 14:55:33 2022 KojiUpdateIOOIMC unlocked again, completely misalignedHmm, the bias values were reset at 2022-03-03-20:01UTC
which is 2022-03-03-12:01 PST with no apparent
disruption of the data acquisition (= no
  
  16711   Mon Mar 7 18:53:16 2022 KojiUpdateBHDRe-susspension of AS1Not sure if that small difference can cause
the alignment inability. Particularly, the
removed metal was just below the wire. This
  
  16719   Wed Mar 9 12:57:52 2022 KojiUpdateBHDSimplified BHD readout sketch on ITMY table- BHD beams were already mixed in the chamber.
So we don't need a BS on the table. (Probably
there is no BS already)
  
  16752   Fri Apr 1 17:02:02 2022 KojiUpdateOptical LeversSimplified sketch on MC tableWe are supposed to have BS Oplev Beams.
We don't like the shallow angle reflections
(i.e. AOI>45deg).
  
  16753   Fri Apr 1 22:22:29 2022 KojiUpdateOptical LeversSimplified sketch on MC tablePossibility to swap BS and ITMX
tables:
BS table, which Tega said MC table,
  
  16758   Wed Apr 6 01:20:48 2022 KojiSummaryBHDPart IIa of BHR upgrade - IR laser alignment on XarmPR2/PR3 Output R for fame OSEMS reduced
from 1.2K to 1.2K//100Ohm

I
 PXL_20220406_060846581.jpgPXL_20220406_014205726.jpgPXL_20220406_060324812.jpgPXL_20220406_015259326.jpg 
  16760   Wed Apr 6 22:51:47 2022 KojiSummaryBHDPart IIa of BHR upgrade - IR laser alignment on Xarm[Yuta Koji]

We took out the two coil driver
units for PR3 and the incorrect arrangement
 PXL_20220406_213356237.MP.jpgPXL_20220406_212936502.MP.jpg 
  16771   Mon Apr 11 21:44:14 2022 KojiSummaryBHDPart IIa of BHR upgrade - POY11 debuggingWe took out the right most PD interface
board D990543 and removed the 74LS04 chips.
In fact two out of 4 were already replaced
 D990543A1.PDFPXL_20220412_023941730.jpgPXL_20220412_023950567.jpg 
  16776   Wed Apr 13 18:55:54 2022 KojiUpdateCamerasCamera Battery TestI believe that the Nikon has an exposure
problem and that's why we bought the
Canon.
  
  16787   Mon Apr 18 23:22:39 2022 KojiUpdateGeneralTool box and Work Station OrganizationWhoa! Thanks!  PXL_20220419_062101907.jpg 
  16791   Wed Apr 20 16:11:08 2022 KojiUpdateSUSOutpur resistors updated for LO1 coil drivers / for SR2, LO2, AS1, and AS4 in progress[JC Koji]

To give more alignment ranges for
the SUS alignment, we started updating the
 6x 
  16792   Wed Apr 20 18:50:03 2022 KojiUpdateBHDPart V of BHR upgrade - PR2 weirdnessIt seemed that it comes from the servo
oscillation. This does not happen when the
output limitters were set to be 100-ish.
 Screenshot_2022-04-20_18-46-11.png 
  16793   Thu Apr 21 10:35:23 2022 KojiUpdateCDSDAQ seemed downYesterday, when I worked on the damping
servo, I found that any of the daqvtools
(ndscope, dtt, dataviewer,...) is not available. 
  
  16795   Thu Apr 21 15:22:44 2022 KojiUpdateSUSOutpur resistors updates for SR2, LO2, AS1, and AS4 done[JC Koji]

Quick report: JC has done all the
mods for the coil driver circuit in the morning
  
  16801   Thu Apr 21 20:33:31 2022 KojiUpdateBHDAS1 UR OSEM problem localized in the chamberTega and Paco reported that the UR OSEM
of AS1 lost the response.

- I have checked the LED MON (left)
 Screenshot_from_2022-04-21_20-13-13.png 
  16809   Mon Apr 25 14:49:02 2022 KojiUpdateGeneralNitrogen TankFor your (and mine) info:

N2 pressure can be monitored on
the 40m summary page: https://nodus.ligo.caltech.edu:30889/detcharsummary/day/20220425/vacuum/
  
  16839   Mon May 9 22:19:06 2022 KojiUpdateBHDBHD Platform Progress status[Don, Koji]

Don is working on finalizing the
BHD Platform design. All the components on
 Screenshot_2022-05-09_220220.pngScreenshot_2022-05-09_222405.png 
  16840   Mon May 9 23:18:44 2022 KojiUpdateBHDBHD Platform Progress statusI quickly ran the FEA model to check the
resonant freqs of the BHD platform.
The boundary conditions were:
 6x 
  16895   Mon Jun 6 22:08:55 2022 KojiUpdateIMCMC1 OSEM sensor sign flipped, MC1/2/3 free swinging overnight for inmat diagonalizationNote that MC1 has a new style sat amp because
the old one collapsed. The sign flip might
have been the result of the replacement
  
  16900   Wed Jun 8 16:03:12 2022 KojiUpdateVACPower Outage 220608: Vacuum Recovery=== Observation ===


TP1/2/3 failed. AUX RP
did not survive the power outage (of course)


===
 Screenshot_2022-06-08_16-43-13.png 
  16901   Wed Jun 8 16:33:26 2022 KojiUpdateGeneralPower Outage 220608: HVAC restoredI found the HVACs for the ends were off.
They were turned back on.
  
  16902   Wed Jun 8 16:57:46 2022 KojiUpdateIOOPower Outage 220608: IMC restoredThe IMC alignment was restored and the
IMC is nicely locking.

Once the vacuum level recovered
  
  16917   Wed Jun 15 15:03:41 2022 KojiUpdatePSLPMC input beam alignedThe commissioners complained about the
PMC alignment. The PMC input beam was aligned.
It made the transmission improved from 0.72
 Screenshot_2022-06-15_15-03-16.pngPXL_20220615_212304650.jpg 
  16918   Wed Jun 15 15:07:07 2022 KojiUpdateSUSLO2 SUS stuck fixedI checked the state of the LO2 suspension.
I found that the coil driver Enable
Mon was all red.
 Screenshot_2022-06-15_15-00-22.pngScreenshot_2022-06-15_15-00-40.png 
  16928   Fri Jun 17 13:07:08 2022 KojiUpdateBHDComparison of MICH OLTF model with measurementI'm curious why the actual OLTF included
the 60Hz comb...? It is undesirable to have
such structure in the OLTF around the UGF
  
  16941   Wed Jun 22 19:41:13 2022 KojiUpdateLSCDaily alignment work; POY trouble solvedBefore the final measurement of the DC
values for the transmissions, I aligned the
PMC. This made the PMC trans increased from
  
  16947   Sat Jun 25 20:23:59 2022 KojiUpdateIOOWFS issuesI could run the WFS servo (6dofs) for more
than 15min by flipping the sign for the MC2
Pit and WFS1 Yaw. (See attachments)
 Screen_Shot_2022-06-25_at_20.23.21.pngScreen_Shot_2022-06-25_at_20.29.24.png 
  16969   Fri Jul 1 12:49:52 2022 KojiUpdateIOOMC2 seemed misaligned / fixedI found the IMC was largely misaligned
and was not locking. The WFS feedback signals
were saturated and MC2 was still largely
 C1-MULTI_FBDB3F_TIMESERIES-1340668818-86400.pngC1-LOCKED_MC_5E4267_TIMESERIES-1340668818-86400.png 
  16982   Fri Jul 8 23:10:04 2022 KojiSummaryGeneralJuly 9th, 2022 Power Outage Prep The 40m team worked on the power outage
preparation. The detailed is summarized on
this wiki page. We will still be able to
  
  16987   Mon Jul 11 17:41:52 2022 KojiHowToVACStartup after Power Outage- Once the FRG gauge readings are back
(see next elog by Tega), I could open V1
to pump down the main vacuum manifold.
 Screen_Shot_2022-07-11_at_18.13.00.png 