40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 118 of 341  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  2044   Fri Oct 2 17:00:06 2009 AlbertoUpdateGeneral40m Update - Requirements on the 5x Frequency MultiplierHere's the gist of the requirements on
the 5x frequency multiplier for the upgrade
(see attachemnt - despite the preview down
 DesignOfTheMultiplier1-14-15.pdf 
  2070   Thu Oct 8 20:18:56 2009 KojiSummaryGeneralArm cavity lossLast night (Oct 07), I ran armLoss script
in order to obtain the latest numbers for
the arm cavity loss.
  
  2071   Thu Oct 8 21:32:59 2009 KojiSummaryGeneralRecycling cavity lossI looked at the data of the day before
yesterday (Oct 06) to know how much is the
recycling gain.
  
  2091   Wed Oct 14 15:48:26 2009 MottHowToGeneralPhase Noise measurementI have gotten the hang of the procedure
for measuring phase noise on the AOMs. 
Koji suggested I right up a short
  
  2103   Fri Oct 16 12:40:59 2009 KojiConfigurationGeneralSome questionsSome questions came arise to me:
A. How the green injection system
should be? How the handing off between 532
  
  2108   Sun Oct 18 15:46:08 2009 AlbertoConfigurationGeneralAntique, unused QPD removed from the AS table Inspecting the AS table to make an inventory
of the photodiodes in use around the interferometer,
I found a mysterious photodetector hiding
  
  2117   Mon Oct 19 13:00:53 2009 MottUpdateGeneralPhase Noise MeasurementHere is the result for the measurement
of the phase noise.  We used the marconi
function generator and compared it with an
 PhaseNoiseWithError.jpgG.jpgPSD.jpg 
  2140   Sun Oct 25 14:29:45 2009 haixing, kiwamuConfigurationGeneralSR785 spectrum analyzerIn this
morning, we have disconnected SR785 which
  
  2149   Tue Oct 27 15:55:04 2009 KojiUpdateGeneralISS injection work / HEPA is onI was working on the ISS excitation to
take TFs.
I used ISS IL excitation, stealing
  
  2166   Sun Nov 1 17:58:44 2009 JenneUpdateGeneralUpdate on Video SwitchThe current update on the Chameleon video
switch is: no progress.
I connected the old laptop that Rob/Steve
  
  2180   Thu Nov 5 16:24:40 2009 JenneUpdateGeneralDrill Press is down for the countThe on/off switch for the drill press is
broken.  Replacement parts should be
here tomorrow. 
  
  2202   Fri Nov 6 23:02:44 2009 HaixingUpdateGeneralSR785 Spectrum AnalyzerI am using SR785 Spectrum Analyzer now
and also tomorrow.  
I will put it back on Sunday. If anyone
  
  2203   Sat Nov 7 23:50:45 2009 HaixingUpdateGeneralOpen-loop transfer function of the magnetic levitation systemI measured the open-loop transfer function
of the magnetic levitation system.
The schematic block diagram for this
 Transfer_function_meas.jpgmagnetic_levitation.jpgtransfer_function_meas_bd.PNG 
  2218   Mon Nov 9 15:21:37 2009 JenneUpdateGeneralDrill Press is down for the count

    
        
  
  2245   Wed Nov 11 21:30:20 2009 HaixingUpdateGeneralmagnetic levitation modelling files uploaded to svnI have created a directory under the svn.
The link is https://nodus.ligo.caltech.edu:30889/svn/trunk/docs/haixing
  
  2275   Mon Nov 16 15:58:02 2009 josephbConfigurationGeneralAdded Gige camera to AP table, added some screensI placed a GC750 gige camera looking at
a pickoff of the AS port, basically next
to the analog camera, on the AP table.
  
  2284   Tue Nov 17 21:09:17 2009 Jenne, ranaUpdateGeneralLittle Thorlabs Photodiode[Rana, Jenne]
We opened up the little Thorlabs
battery operated PD to see what was inside. 
 ThorlabsPD.png 
  2362   Mon Dec 7 19:02:22 2009 MottUpdateGeneralReflectivity Measurements I have made some measurements of the R
value for some coatings we are interested
in.  The plots have statistical error
 Y1-45P_R.pngY1-45S_R.pngY1-50CC_R.png 
  2392   Thu Dec 10 18:27:48 2009 MottUpdateGeneralUpdated R & T MeasurementsAttached are updated plots of the T&R
Measurements for a variety of mirrors, and
diagrams for the setup used to make the measurements.
 6x 
  2401   Fri Dec 11 17:36:37 2009 kiwamuUpdateGeneralIFO restoring planAlberto,
Jenne, Kiwamu
 
  
  2415   Mon Dec 14 19:33:04 2009 AlbertoUpdateGeneralArm Cavity Poles measured again after cleaning the optics last weekLast week we vented and we cleaned the
main optics of the arm cavities.
I measured the frequency of the cavity
 XarmTF01_fit.pdfYarmTF01_fit.pdfArmCavityFinesseMeasurment.tar.gz 
  2416   Mon Dec 14 22:32:56 2009 KojiUpdateGeneralArm cavity loss ~ resultI like to ask someone to review the calculation
on the wiki.
  
  2418   Tue Dec 15 05:29:31 2009 AlbertoUpdateGeneralArm Cavity Poles measured again after cleaning the optics last week 
 The Y arm cavity pole moved
down by 130 Hz, whereas the X arm moved by
  
  2419   Tue Dec 15 17:16:22 2009 KojiUpdateGeneralTable distance measurementsDuring the vent we have tried to measure
the distances of the optical tables for BS-ITMX
and BS-ITMY.
 Table_distance_by_metal_scale.pdfTable_distance_by_chambers.pdf 
  2446   Tue Dec 22 15:49:31 2009 kiwamuUpdateGenerale-log restartedI found the e-log has been down around
3:40pm, then I restarted the e-log. Now it's
working.
  
  2452   Sat Dec 26 19:22:13 2009 KojiSummaryGeneralMode coupling of two astigmatic beamsIn this note, amplitude and power couplings
of two astigmatic (0,0)-th order gaussian
modes are calculated.
 mode_coupling.pdf 
  2467   Wed Dec 30 10:58:48 2009 AlbertoUpdateGeneralAll watchdogs tripped this morningThis morning I found all the watchdogs
had tripped during the night.
I restored them all.
  
  2468   Wed Dec 30 18:01:03 2009 Alberto, RanaUpdateGeneralAll watchdogs tripped this morning


   
        
            
  
  2470   Wed Dec 30 22:17:07 2009 kiwamuUpdateGeneralCamera input and monitor outputThe input channels of the cameras and
the output channels for the monitors are
summarized on the
  
  2474   Mon Jan 4 17:26:01 2010 MottUpdateGeneralT & R plots for Y1 and Y1S mirrorsThe most up-to-date T and R plots for the
Y1 and Y1S mirrors, as well as a T measurement
for the ETM, can be found on:
  
  2499   Sun Jan 10 23:22:56 2010 JenneSummaryGeneralScattering Measurements of 35W Beam DumpsOn Friday, Rana and I measured the scatter coming from  P1090014_copy.JPGScatterometerSetup.png 
  2500   Mon Jan 11 09:18:44 2010 AlbertoUpdateGeneralMeasurement runningI'm working on the AbsL experiment. A measurement
which involved the PRC locked is running
at the moment.
  
  2507   Tue Jan 12 09:14:52 2010 steveSummaryGeneralScattering Measurements of 35W Beam Dumps 
 What was the power level, polarization
and beam size at beam trap?
  
  2568   Wed Feb 3 11:13:15 2010 steveConfigurationGeneralplaned power outage for Sat. Feb 20The electrical shop has to connect the
new power transformer at CES. This means
we will have no AC power for ~8 hrs on Saturday,
  
  2585   Wed Feb 10 16:27:47 2010 steveConfigurationGeneral IFO beam heightsIN
VACUUM beam heights are ALL 5.5" 
This is measured from the top of the
  
  2612   Thu Feb 18 10:10:43 2010 steveConfigurationGeneral480 V AC power turned offOnly the 40m cranes are running on 480VAC
The electricians are rewiring this transformer
on the mezzanine so it was shut down.
  
  2617   Fri Feb 19 13:28:44 2010 KojiUpdateGeneralPrep for Power Supply Stop - ETMX/ETMY oplev paths renewed. The nominal
gain for ETMY YAW was reversed as a steering
mirror has been put.
 screen_shot.png 
  2620   Sun Feb 21 17:44:35 2010 ranaUpdateGeneralPrep for Power Supply Stop [LIST]
[*] Turned on the RAID attached to linux1
(its our /cvs/cds disk)
  
  2621   Mon Feb 22 07:25:58 2010 ranaUpdateGeneralPrep for Power Supply Stop Autoburts have not been   
  2622   Mon Feb 22 09:45:34 2010 josephbUpdateGeneralPrep for Power Supply Stop

    
        
  
  2625   Mon Feb 22 11:42:48 2010 KojiUpdateGeneralPrep for Power Supply Stop Turned on the power supply for the oplev
lasers.
Turned on the power of the aux NPRO.
  
  2630   Tue Feb 23 06:47:57 2010 KojiUpdateGeneralIFO situations / low power MC lockWork on 22nd Monday:
[MC
recovery]
- Tried to lock MC
after the computer recovery by Joe.
 MC_incident.pngMC_REFL.png 
  2632   Tue Feb 23 14:56:24 2010 steveUpdateGeneralETMX optical table massOur janitor dropped one 48" long 
fluorescent tube on the top cover of ETMX-isct.
This accident made glasses fly all over the
 etmxmass.jpg 
  2639   Thu Feb 25 11:21:06 2010 KojiUpdateGeneralTanks opened[Steve, Bob, Joe, Zach, Alberto, Kiwamu,
Koji]
We opened the OMC-IMC access connector,
  
  2643   Fri Feb 26 11:48:36 2010 KojiUpdateGeneralMC incident beam shiftLast night I worked on the MC incident
beam such that we can hit the center of the
MC mirrors.
  
  2645   Sun Feb 28 16:45:05 2010 ranaSummaryGeneralPower ON Recovery
    Turned ON the RAID above linux1.

   Hooked up a monitor and keyboard and
then turned ON linux1.
    After
  
  2664   Tue Mar 9 09:32:31 2010 KojiSummaryGeneralWideband measurement of Fast PZT responseI have measured a wideband response
of the fast PZT in the LWE NPRO 700mW in
the Alberto's setup.
 PZT_response.png 
  2709   Wed Mar 24 12:40:25 2010 daisukeConfigurationGeneralPeriscope for green laser delivery from the BSC to PSL tableThe periscope design for beam elevation
of the green beams is posted. The design
for the 90 deg steering version is also coming.
 40m_periscope.png40m_periscope_A_100329.pdf40m_periscope_A_dwg_100329.zip 
  2725   Mon Mar 29 01:45:26 2010 daisukeConfigurationGeneralPeriscope version B for green laser ...Here the design of the periscope for the
90 deg steering version is posted.
straight version http://nodus.ligo.caltech.edu:8080/40m/2709
 40m_periscope_B.png40m_periscope_B_100329.pdf40m_periscope_B_dwg_100329.zip 
  2746   Thu Apr 1 00:43:33 2010 MottUpdateGeneralPZT response for the innolightKiwamu and I measure the PZT response of
the Innolight this evening from 24 kHz to
2MHz.  
 Innolight_Bode.png 
ELOG V3.1.3-