40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 117 of 170  Not logged in ELOG logo
Entry  Wed Oct 27 02:26:15 2010, kiwamu, Update, IOO, MC locked  
(Rana, Koji, Suresh, Yuta, Thanh, Kiwamu)
 MC was 
Entry  Tue Oct 26 17:31:17 2010, yuta, Update, CDS, fixed OPLEV stuff and MCL filters optlevMC2.png
(Joe, Yuta)

Background:
    Reply  Tue Oct 26 21:27:02 2010, Jenne, Update, CDS, fixed OPLEV stuff and MCL filters 
Since MC2_TRANS is, in fact, MC2 Transmission, and not an oplev at all (it's not red, and it's not a lever, although it does use a QPD), I propose that
the name be changed to something sensical, since calling it an oplev is completely non-sensical.  The name change should happen sooner rather than
later, to avoid confusion.
Entry  Tue Oct 26 16:02:55 2010, yuta, HowTo, CDS, things to do after making a new Simulink model 
(Joe,Yuta)

Things to do after making a new Simulink model.
Entry  Tue Oct 26 15:57:10 2010, Jenne, Update, SUS, One magnet broken, reglued 
[Jenne, Suresh, Thanh (Bram's Grad Student)]
When we removed the grippers from the magnets on the PRM, one of the face magnets broke off.  This time, the dumbbell remained glued to the
optic, while the magnet came off.  (Usually the magnet and dumbbell will stay attached, and both come off together).  I had 3 spare magnet-dumbbells,
Entry  Wed Oct 13 18:01:43 2010, yuta, HowTo, CDS, editting all the similar medm screens 
(Joe, Yuta)

Say, you want to edit all the similar medm screens named C1SUS_NAME_XXX.adl.
    Reply  Thu Oct 14 00:54:12 2010, rana, HowTo, CDS, Bad PSL Quad, so I edited the SUS MEDM screens Untitled.png
We found today that there was some (unforgivably
un-elogged) PSL-POS & PSL-ANG work today. 
The wedge splitter at the end of the PSL table is so terribly dogged that it actually moves around irreversibly if you touch the post a
    Reply  Tue Oct 26 12:45:20 2010, yuta, HowTo, CDS, making a new master file for medm screens 
(Joe, Yuta)

 In elog #3708, we showed how to edit all the similar medm screens easiliy.
Entry  Sun Oct 24 19:23:41 2010, rana, Configuration, elog, ELOG 2.8.0 
[SIZE=4][COLOR=blue][FONT=Comic Sans MS][B]I stopped the ELOG and restarted us on 2.8.0.[/B][/FONT][/COLOR][/SIZE]

To make sure nothing got lost, I killed the old process, copied over the logbooks/, themes/, and elogd.cfg to the new 2.8.0/ directory before starting
    Reply  Mon Oct 25 02:23:47 2010, Koji, Configuration, elog, ELOG 2.8.0 
When I push the reply button, the raw html shows up in the edit window and have to use HTML to write the entry.
Does this happen only to me??? 
Entry  Tue Oct 26 01:53:21 2010, Joonho Lee, Update, Electronics, Fuction Generator removed. 
Today I worked on how to measure cable impedance directly.
In order to measure the impedance in RF range, I used a function generator which could generate 50MHz signal
and was initially connected to the table on the right of the decks.
Entry  Tue Oct 26 00:45:08 2010, rana, Update, PSL, New NPRO Diagnostic Wiring Untitled.png

I copy section 6.2 into here to share with you all what the diagnostic
Entry  Mon Oct 25 23:10:06 2010, Koji, Update, IOO, MC is now flashing 
[Suresh / Koji]
The MC mirrors are aligned. Now the flashing of the resonances are visible
on the MC2 CCD
Entry  Mon Oct 25 20:20:59 2010, yuta, Joe, Update, CDS, DAQ channel number etc 
[U][B]Summary:[/B][/U]
  We split the old SDSEN filters to SDSEN, SDSIDE, SDCOIL last week.
  Along with this change, the TP channel number changed unfortunately.
Entry  Mon Oct 25 11:39:06 2010, Jenne, Update, SUS, Magnets glued to PRM StatusTable.png
This morning I glued the magnets to the PRM.  Now we wait, and tomorrow afternoon (at the earliest), Suresh and I can balance the PRM.
Entry  Fri Oct 22 03:37:56 2010, Kevin, Update, PSL, Quarter Wave Plate Measurements 
[Koji and Kevin]
We measured the reflection from the PBS as a function of half wave plate rotation for five different quarter wave plate rotations. Before the measurement
we reduced the laser current to 1 A, locked the PMC, and recorded 1.1 V transmitted through the PMC. During the measurements, the beam was blocked after
    Reply  Sat Oct 23 02:25:49 2010, Kevin, Update, PSL, Quarter Wave Plate Measurements fits.png


    
        
            Quote:
        
        
            
            [Koji and Kevin]
       Reply  Mon Oct 25 02:25:21 2010, Koji, Update, PSL, Quarter Wave Plate Measurements 
Q1. Suppose the laser beam has a certain (i.e. arbitrary) polarization state but contains only TEM00. Also suppose the PSB is perfect (reflect all S
and transmit all P). What results do you expect from your expereiment?

Q2. Suppose the above condition but the PBS is not perfect (i.e. reflects most of S but also small leakage of P to the reflection port.) How
Entry  Fri Oct 22 18:15:21 2010, kiwamu, Update, Locking, Green era: found a green beat note finally green_beatnote.jpg
finally we found it !
 
    Reply  Fri Oct 22 21:28:27 2010, Aidan, Update, Locking, Green era: found a green beat note finally 
Nice work!
       Reply  Sun Oct 24 18:06:35 2010, kiwamu, Summary, Locking, setup for green beat green_beat_note.png

(notes on signal level)
          Reply  Mon Oct 25 02:14:38 2010, Koji, Summary, Locking, setup for green beat 
- What is the actual photocurrent for the beam1 and beam2? We don't care how much power do you have before the BS, but care how much current do you have
on the PD.
- How much is the visibility? There is mismatching of the beams. i.e. The beam diameter looked quite different. Also the beams are not TEM00 but
Entry  Sun Oct 24 19:55:50 2010, kiwamu, Update, Electronics, lonely RF amplifier on ITMX table 
(Rana, Kiwamu) 



 Last Friday we found a lonely RF amplifier ZHL-3A on the ITMX table. 
Entry  Sat Oct 23 14:42:01 2010, yuta, Summary, CDS, damped MC suspensions dam.png
After replacing filters, MC suspensions damped  last night.
Further measurement next time.
Entry  Fri Oct 22 19:53:27 2010, yuta, Summary, CDS, conversion failure in digital filters 
(Rana, Joe, Yuta)

We now understand that we never succeeded in converting old fiter files to new filter files.
    Reply  Sat Oct 23 03:36:05 2010, yuta, Update, CDS, fixed filters for C1SUS, C1RMS, C1MCS 
(Joe, Yuta)

Summary:
Entry  Fri Oct 22 16:59:21 2010, Jenne, Update, Electronics, Epic Takeover 
As the suspension work winds down (we'll be completely done once the ETMs arrive, are suspended, and then are placed in the chambers), I'm going to start
working on the RF system. 
Step 1: Figure out what Alberto has been up to the last few months.
    Reply  Fri Oct 22 18:22:27 2010, Alberto, Update, Electronics, Epic Takeover 


    
        
            Quote:
        
        
            
            As the suspension work winds down (we'll be completely done once the ETMs arrive, are suspended, and then are placed
Entry  Fri Oct 22 15:06:43 2010, Jenne, Update, SUS, Arts and Crafts! StatusTable.png
This afternoon I epoxied the guiderod and wire standoff to the new PRM.  I also epoxied the magnets that Suresh picked out to the dumbbell standoffs. 
We'll let them all cure over the weekend, and then I'll glue the magnets to the optic on ~Monday.
Notes about the epoxy: 
Entry  Thu Oct 21 18:45:50 2010, Koji, Update, PSL, Found the beat at 1064nm 
[Koji Suresh]
We found the beat at 1064nm. T(PSL)=26.59deg, T(X-end)=31.15deg.
The X-end laser was moved to the PSL table.
    Reply  Thu Oct 21 19:10:39 2010, Aidan, Update, PSL, Found the beat at 1064nm 


       Reply  Fri Oct 22 01:23:13 2010, Koji, Update, PSL, Found the beat at 1064nm 101021_beat.pdf
[Koji / Suresh]
We worked on the 1064 beating a bit more.
- First of all, FSS and FSS SLOW servo were disabled not to have variating Xtal temp for the PSL.
Entry  Thu Oct 21 05:51:10 2010, kiwamu, Update, Locking, no green beat note 
 Still I didn't see any beat note signals..
 With a help from Suresh, Yuta and Rana, I tried searching for the green beat note by changing the temperature of the X end NPRO.
The noise level after it goes through an RF amplifier (G=23dB) was about -70dBm at 50MHz.
    Reply  Thu Oct 21 15:59:28 2010, kiwamu, Update, Locking, no green beat note : details bw.png
Last night I tried searching for a beat note signal with two different PD trans impedance gains. 
Although I didn't find a  beat note signal.
 
Entry  Thu Oct 21 01:11:48 2010, rana, Summary, Computers, elog change and rossa tex 
I deleted a bunch of categories from the elogd.cfg file. Not every kind
of locking and activity gets its own activity. All of the things related to length sensing and control should be LSC. If there's a high pollen count its
under PEM. etc., etc., etc.
    Reply  Thu Oct 21 13:05:19 2010, Koji, Summary, Computers, elog change and rossa tex 
This is cool though the projector is flashing the blue screen alternately. 
I gave the dual head video card (ATI RADEON something) to Yuta a month ago. 
Entry  Thu Oct 21 12:15:02 2010, rana, Update, PEM, 6.9 Mag EQ in Gulf of California 

    
        
            Magnitude

           6.9
        
        
            Date-Time

           
            
                Thursday, October 21, 2010 at 17:53:14 UTC
                Thursday,
Entry  Thu Oct 21 10:44:56 2010, steve, Metaphysics, Treasure, 1987 supernova tapes plus....? P1060932.JPG
I'm cleaning out to make room for our new optical cabinet. Are we keeping these? There are  ~20  pieces of 10" od 1" wide tapes and
large number of cassettes.
AJW,  Zucker,  Stuart A and Koji were notified in this matter.
Entry  Wed Oct 20 21:33:11 2010, Kevin, Update, PSL, Quarter Wave Plate Optimization 
[Suresh and Kevin]
We placed the quarter wave plate in front of the 2W laser and moved the half wave plate forward. To make both wave plates fit, we had to rotate
one of the clamps for the laser. We optimized the angles of both wave plates so that the power in the reflection from the PBS was minimized and the transmitted
Entry  Wed Oct 20 18:17:35 2010, Suresh, Jenne, Update, SUS, PRM assembly 
We have positioned the guide rod and the wire-stand-off on the optic in the axial direction. 
We have selected six magnets whose magnetic strength is +/-5% of their mean strength (180 Gauss).  The measurement was made as follows:
1) each magnet was placed on its  end, on the top of a beaker held upside down. 
Entry  Wed Oct 20 16:41:41 2010, steve, Omnistructure, General, laser chiller leaving for MIT P1060929.JPG
 
Entry  Tue Oct 19 21:10:27 2010, yuta, Update, CDS, bad filter coefficients for every suspensions! 
(Koji, Yuta)

Summary:
    Reply  Wed Oct 20 01:22:18 2010, yuta, Update, CDS, fixed filters for MCs, but no damping Screenshot.png
(Rana, Yuta)

Summary:
Entry  Tue Oct 19 22:37:28 2010, Koji, Update, PSL, PSL table cleaning up 
I cleaned up the scattered tools, optics, and mounts of the PSL table. I gathered those stuffs at the two coners.
At the end of the work I scanned the table with an IR viewer. (This is mandatory)
I put some beam block plates to kill weak stray beams.
Entry  Tue Oct 19 15:14:51 2010, Jenne, Update, SUS, PRM (little) update 
[Jenne, Suresh]
We've aligned the guiderod and wire standoff to the PRM, each partly.  They have both been aligned to the correct distance above the scribe
lines, but they have not yet been centered forward/backward along the thickness of the optic.  So, we're working on it...
Entry  Tue Oct 19 00:24:07 2010, Dmass, Omnistructure, Electronics, Massive restocking of the 40m 
I had a number of delinquent items on the sign out list from the 40m. I returned about half, and ordered replacements for most of the other half.
I put the photodiodes on the SP table, and the 560 on the electronics  bench.
Entry  Mon Oct 18 22:11:32 2010, Joonho Lee, Summary, Electronics, CCD cables for input signal 
Today I checked all the CCD cables which is connected input channels of the VIDEOMUX.
Among total 25 cables for output, 12 cables are type of RG59, 4 cables are type of RG58, and 9 cables are
of unknown type.
Entry  Mon Oct 18 18:33:46 2010, Koji, Summary, COC, Summary of the main mirrors & their phasemap measurement 
I have made a summary web page for the 40m upgrade optics.
https://nodus.ligo.caltech.edu:30889/40m_phasemap/
I made a bunch of RoC calculations along with the phase maps we measured. 
Entry  Mon Oct 18 17:16:30 2010, Jenne, Update, SUS, Old PRM, SRM stored, new PRM drag wiped 
[Jenne, Suresh]
We've put the old PRM and SRM (which were living in a foil house on the cleanroom optical table) into Steve's nifty storage containers.  Also,
we removed the SRM which was suspended, and stored it in a nifty container.  All 3 of these optics are currently sitting on one of the cleanroom optical
    Reply  Mon Oct 18 18:00:36 2010, Koji, Update, SUS, Old PRM, SRM stored, new PRM drag wiped 
- Steve is working on the storage shelf for those optics.
- PRMU002 was chosen as it has the best RoC among the three.


    
        
            
Entry  Mon Oct 18 15:33:00 2010, josephb, alex, Update, CDS, Possibly broken timing cards 
It looks as though we may have two IO chassis with bad timing cards.
Symptoms are as follows:
We can get our front end models writing data and timestamps out on the RFM network.
Entry  Mon Oct 18 11:22:13 2010, Jenne, Update, Computers, Shame on people not elogging! FrameFiles backups not working. 
On the one hand, SHAME ON ALL PEOPLE WHO DON'T ELOG THINGS,
such as the moving of scripts directories (it was a pain to figure out that that's part of why the backup scripts are broken).  On the other hand,
the moving of the scripts directories brought to light a critical problem in the backup scheme. None of the
Entry  Mon Oct 18 09:01:48 2010, steve, HowTo, General, How not to  P1060926.JPG
This BNC cable is crying for help. Please do not do this to me.  It should be reported  to the  abused center.Throw this cable into the
garbage now.
Entry  Fri Oct 15 15:32:35 2010, josephb, Update, CDS, slow DAQ channels added 
I added all the _OUT16, _INMON, _EXCMON channels associated with the BS, ITMX, and ITMY channels in SUS_SLOW.ini
in the /opt/rtcds/caltech/c1/chans/daq directory.  Similarly, I added the channels associated with MC1, MC2, and MC3 to MCS_SLOW.ini and those associated
with PRM and the SRM to RMS_SLOW.ini. 
    Reply  Mon Oct 18 08:44:36 2010, rana, Update, CDS, slow DAQ channels added 
Why EXCMON? I think that we should modify the filter coefficients so that the decimation filter that makes OUT16 is a 2nd order Butterworth at
1 Hz instead of whatever bogus thing it is now. Then we can delete the EXCMON from the DAQ and add either OUTPUT or OUTMON. That way we will have a low
frequency signal (OUT16) and a sort of aliased RMS (OUTMON).
Entry  Thu Oct 14 00:53:44 2010, kiwamu, Update, SUS, what's wrong with MC2 OSMEs.png
It turned out that the DC alignment of MC2 from epics doesn't helathily work.
For example, the pitch slider does drive the yaw alignment as well.
 
    Reply  Fri Oct 15 22:16:22 2010, kiwamu, Update, SUS, what's wrong with MC2 
[Yuta, Suresh, Rana and Kiwamu]
 The DC alignment problem of MC2 was fixed.

        
Entry  Fri Oct 15 21:25:23 2010, Suresh, Update, IOO, 2W NPRO laser output power drop question 
  The power meter used in the measurements of elog entries 2822, 3698 and 3709 was the Ophir PD300-3W.  This power head has several damaged
patches  and a slight movement of the laser spot changes the reading considerably.  To verify I checked the power out with another power meter
(the Vector S310) and found that there is no significant variation of the power output with the temperature of the laser.  And the power at 2.1A of
Entry  Wed Oct 13 00:35:26 2010, kiwamu, Update, Green Locking, PSL beat note setup 
[ Kevin and Kiwamu ]
 We made the setup for the green PLL stuff on the PSL table.
 Now the two green beams are happily going to the RFPD.
    Reply  Fri Oct 15 06:31:52 2010, kiwamu, Update, Green Locking, PSL beat note setup: part II 
 I made some KAIZENs (what
does kaizen mean ? ) for the PSL green setup.
I replaced the lenses for the modematching of the two green lights at the PSL table, and the beams now
Entry  Thu Oct 14 23:33:45 2010, Suresh, Update, IOO, 2W NPRO laser output power versus temperature tempscan.pngScan2010.zip
Steve measured an apparent power drop in the 2W NPRO output from 2.1W to 1.6W(elog entry no 3698)
at 2.1A of diode current in the laser (elog entry:  2822).  It was later noticed that the laser temperature was set to about 45 degC while
    Reply  Fri Oct 15 00:15:52 2010, Koji, Update, IOO, 2W NPRO laser output power versus temperature 
From the plot, you observed the reduction of the output power only by 1% between 25deg to 45deg.
This does not agree with the reduction from 2.1W to 1.6W.
Is there any cause of this discrepancy?
Entry  Fri Oct 8 12:29:21 2010, Kevin, Update, Computers, New Netgear Switch 
I removed some old equipment from the rack outside the control room and stacked them next to the filing cabinets in the control room. I also mounted
the new Netgear switch in the rack.
    Reply  Thu Oct 14 22:26:38 2010, Koji, Update, Computers, New Netgear Switch 
The network cables for the Martian network were moved to the new Netgear switch from the old one
which had the broken fan.
The martian machines look happy so far.
Entry  Thu Oct 14 20:49:50 2010, yuta, Update, Computers, automated Q-value adjuster MC3_SUSPOS.png
Background:
 Now we can use pyNDS(see elog #3722), so I wrote a python script that adjusts Q-value
automatically.
Entry  Thu Oct 14 14:52:52 2010, Leo Singer, Configuration, Computers, numpy, ipython, matplotlib, python-matplotlib installed on rossa 
I installed the following packages on rossa:
numpy, ipython, matplotlib, python-matplotlib
Entry  Thu Oct 14 14:09:30 2010, josephb, Update, CDS, NDS 2 server status 
[Joe, John]
The nds 2 server is about 50% of the way there.  You can connect to it and get channel lists, but its having issues actually serving the data. 
The errors we're getting basically say it can't find the source data for the channel
Entry  Thu Oct 14 13:15:14 2010, Leo Singer, Configuration, Computers, git installed on rossa 
I installed git on rossa using:
$ sudo yum install git
Entry  Thu Oct 14 13:09:01 2010, Leo Singer, Configuration, Computers, nds2-client-devel installed on rossa 
I installed nds2-client-devel on rossa using the following command:
$ sudo yum install nds2-client-devel
Entry  Thu Oct 7 14:39:50 2010, yuta, Update, PSL, measured PMC's laser power-output relation PMCreflect.png
(Rana, Yuta)

Motivation:
    Reply  Thu Oct 7 15:05:46 2010, Koji, Update, PSL, measured PMC's laser power-output relation 
It was a bit difficult to comprehend the result.
Is it good? or bad? Have you seen the thermal effect? or not?
- Put linear lines to show the visibility of the cavity.
       Reply  Thu Oct 7 16:34:06 2010, yuta, Update, PSL, measured PMC's laser power-output relation PMCvis.png
Result2:
 Attached is the visibility vs incident power(assuming output of the PD is proportional to the input laser power).
 Ideally, the graph should be flat. (In another words, attached graph in the elog #3667 shoud be linear.)
          Reply  Thu Oct 14 12:53:29 2010, yuta, Update, PSL, mesured PMC's visibility vs power relation PMCsetup.pngPDcalib.pngPMCreflect2.png
Background:
 I measured the PMC's visibility vs incident power relation last week to see the thermal effect, but I didn't calibrated the laser power(see
elog #3672).
Entry  Thu Oct 14 12:45:47 2010, josephb, Update, Computers, NDS 2 server installation on mafalda 
[Joe, John Zweizig]
John stopped by around noon today to install the NDS 2 server.  He installed it /cvs/cds/caltech/users/jzweizig/nds2-server/.
Once John is done, I will be moving this to a more sensible install location that is not his user directory, but its there for the moment.
Entry  Thu Oct 14 10:59:10 2010, josephb, Update, Computers, Updated cshrc.40m and Computer Restart Procedures 
I started modifying the cshrc.40m file in /cvs/cds/caltech/ so that it starts pointing at the new directories.
# misc aliases
alias target 'cd /opt/rtcds/caltech/c1/target'
ELOG V3.1.3-