  674   Tue Jul 15 12:23:22 2008 JenneUpdateGeneralMC2 Watchdog trippedAlberto, Jenne

Mode Cleaner was unlocked.  We checked, and
  
  683   Wed Jul 16 16:59:07 2008 AlbertoUpdateGeneralAligmentI think the two beams are aligned again -
they both pass the Faraday, they match at
the irises and all along the optical path
  
  687   Thu Jul 17 00:59:18 2008 JenneSummaryGeneralFunny signal coming out of VCOWhile working on calibrating the MC_F signal,
Rana and I noticed a funny signal coming
out of the VCO.  We expect the output to
 VCOout_time.PNGVCOout_freq.PNG 
  706   Mon Jul 21 11:54:00 2008 JenneUpdateGeneralMC Servo BoardI pulled the MC Servo Board again, to check
the components that are on the board, and
compare them with the schematics.  The filters
  
  727   Wed Jul 23 21:48:30 2008 robConfigurationGeneralrestore IFO when you're done with it
[SIZE=3][B]when you are done with the IFO,
please click "Restore last auto-alignment"[/B][/SIZE]
  
  738   Fri Jul 25 10:48:13 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Realignment / beating / PLL trialAlberto and Koji

o We worked for the abs length measurement
  
  748   Mon Jul 28 15:54:04 2008 KojiUpdateGeneralAbs. Len. Meas. ~ More on the beat / the PLL setupAlberto and Koji,

Last Friday evening, Koji found that the
 PLL_setup.pngbeat_at_8MHz.jpg 
  774   Thu Jul 31 10:24:32 2008 KojiUpdateGeneralIFO statusLast night I used the Y-arm for the abs length
measurement. The Yarm was aligned by the
script. 
  
  776   Thu Jul 31 11:19:30 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Resonance search trialLast night, I tried to find the resonance
of Yarm by sweeping the frequency of the
injection beam.
  
  782   Sat Aug 2 12:53:43 2008 KojiUpdateGeneralAbs. Len. Meas. ~ New PLL at the PSL table[B]Report of the work last night:[/B]
The new heterodyne interferometer on the
PSL table was built.
 yarm_dc.png 
  783   Sat Aug 2 13:07:23 2008 KojiConfigurationGeneralThe AP table cleanedDuring the construction of the independent
PLL I cleaned up some of the unused optics
from the AP table. Essentially this should
  
  787   Mon Aug 4 00:37:58 2008 KojiUpdateGeneralAbs. Len. Meas. ~ RF PD at the Y end / Manual frequency scan[B]Work log on August 2nd[/B]

o Just remind you:
 YEND_LAYOUT.png4th_FSR1.png4th_FSR2.png 
  788   Mon Aug 4 00:56:07 2008 KojiHowToGeneralAbs. Len. Meas. ~ Auto freq scanner with GPIB[B]Work log on August 3rd  - Part1[/B]

o Yesterday I was too much tired of changing
 freq_scan.png 
  789   Mon Aug 4 05:23:57 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Measurement for Y-arm completedFinally, I have completed the abs length and
g-factor measurements for Y-arm.
[COLOR=green][B]>>>GO FOR THE VENT<<<[/B][/COLOR]
  
  793   Mon Aug 4 21:48:24 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Scan for TEM00/01/10[B]Work log on August 3rd  - Part2[/B]

o I tried to measure the frequency of the
 TEM00.pngTEM01.pngknife_edge.png 
  794   Mon Aug 4 22:31:10 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Simple Test for TEM01/10 split[B]Work log on August 3rd - Part3[/B]

[B]Question:[/B]
 TEM01_10.png 
  795   Tue Aug 5 00:05:57 2008 KojiUpdateGeneralAbs. Len. Meas. ~ IFR2023A calibration[B]Work log on August 4th[/B]

o IFR2023A (Marconi) was calibrated by the
  
  796   Tue Aug 5 02:39:55 2008 KojiConfigurationGeneralAbs. Len. Meas. ~ Optical Layout on the AP / PSL table 2008-Aug-05Here are the PDF and the PNG of the AP and
PSL table layouts.
After this photo, the squeezing setup at
 optical_layout_ap_table3.pngoptical_layout_ap_table3.pdfoptical_layout_PSL_table1.pngoptical_layout_PSL_table1.pdf 
  798   Tue Aug 5 10:56:05 2008 AlbertoConfigurationGeneralITMX chamber opened and mirror releasedD-Mass, Steve, Rana, Koji, Yoichi, Alberto,
We opened the ITMX chamber to check the optics
after last week earthquake. In particular,
  
  800   Tue Aug 5 17:56:23 2008 AlbertoConfigurationGeneralSRM and PRM inspectionYoichi, Koji, Rana, Steve, Alberto

Today we opened the [B]BSC[/B] to inspect
 IMG_1434.JPGIMG_1456.JPG 
  801   Wed Aug 6 11:10:34 2008 KojiUpdateGeneralAbs. Len. Meas. ~ analysis of the TEM00 scan[B]Analysis of the data on August 3th ~ Part
1[/B]
 TEM00fit.pngTEM00FSRfit.png 
  802   Wed Aug 6 11:43:52 2008 KojiUpdateGeneralAbs. Len. Meas. ~ analysis of the TEM01 scan[B]Analysis of the data on August 3th ~ Part
2[/B]
 TEM01fit.png 
  805   Wed Aug 6 19:01:15 2008 AlbertoUpdateGeneralITMX and SRM OSEM post-earthquake diagnosticKoji, Yoichi, Alberto

Today we reset the OSEMs on ITMX and SRM
  
  838   Thu Aug 14 21:52:51 2008 KojiSummaryGeneralAbs. Len. Meas. ~ summary of my SummerI have made the summary of the absolute length
measurement.
It is attached here. The file is a bit big
 mode_spacing_measurement_080816_v2.pdf 
  875   Mon Aug 25 10:23:53 2008 steveHowToGeneralcable killerRack 1Y7 double violation:

BNC cables left to be jammed by door
 cablkill.pngcablkll2.png 
  938   Wed Sep 10 08:57:03 2008 steveUpdateGeneraletmy illuminator turned offThe ETMY illuminator was left on yesterday.
I just turned it off.
  
  940   Wed Sep 10 19:53:53 2008 AlbertoUpdateGeneralabs length experimentUpdate of the last days work on the experiment
to measure the absolute length of the cavities.
  
  943   Thu Sep 11 23:28:35 2008 albertoUpdateGeneralabs cavity length experimentThe MC lost lock for some reason not related
to either the FSS or the PMC I'm done with
my measurement for tonight. I've shut the
  
  944   Fri Sep 12 11:09:20 2008 AlbertoUpdateGeneralabs cavity length experimentI'm leaving the lab for a couple of hours.
I shut the NPRO. The interferometer is available
to anyone.
  
  945   Sat Sep 13 23:13:01 2008 AlbertoUpdateGeneralabs cavity length experimentThe Y arm was locked all time today but, suddenly,
this afternoon it lost lock and since then
I've been unable to restore it. I tried unsuccessfully
  
  946   Sun Sep 14 18:30:32 2008 AlbertoUpdateGeneralABSL: measured X armToday I measured the X arm FSR.
Hi moved the fast PD (Thor Labs PDA255) from
the Y end table to the X end table. I had
  
  947   Sun Sep 14 19:29:07 2008 AlbertoUpdateGeneralABSL: measured X arm[quote]Today I measured the X arm FSR.
Hi moved the fast PD (Thor Labs PDA255) from
the Y end table to the X end table. I had
  
  956   Wed Sep 17 13:58:36 2008 AlbertoUpdateGeneralABSL: results from the X armToday I repeated the measurement of the FSR
on the X arm cavity. The noise in the transmitted
power that made the measures fluctuate was
 Sept17_XarmFSRmeasurement_report.ps 
  960   Wed Sep 17 19:13:47 2008 AlbertoUpdateGeneralABSL: statusI installed the setup for measuring TEM01/10
on the X end table. 
I'm leaving. I shut the laser, flipped down
  
  962   Thu Sep 18 09:30:12 2008 steveUpdateGenerallow noise metal film resistors are inLow noise metal film resistor and capacitor
kits from www.garrettelec.com are in.
 mfr&cap.pngstorcab.png 
  979   Mon Sep 22 20:00:35 2008 AlbertoUpdateGeneralABSL: running measurementI'm leaving the X arm locked on the TEm01
mode while a measurement is running. Just
please wait for 40 minute if you need the
  
  987   Wed Sep 24 17:57:04 2008 AlbertoUpdateGeneralABSL: FSS Slow Actuator ControlRana, Alberto

Today when I started working with the PLL
  
  994   Thu Sep 25 17:14:31 2008 ranaConfigurationGeneralnew sitemap   vegemite.png 
  1030   Tue Oct 7 10:49:29 2008 AlbertoUpdateGeneralDisplaced PhotodiodeThis morning I found that the photodidode
of the PLL in the PSL table was not aligned
to the beam anymore. The PD support was not
  
  1062   Tue Oct 21 16:14:42 2008 steveUpdateGeneraldivergence of He Ne 1035PThe ITM oplevs laser diodes are noisy.
They will be replaced by JDS 1035P
SN T8093307 was measured with the beamscanner.
 1035p_divergence.png 
  1069   Wed Oct 22 17:48:58 2008 YoichiUpdateGeneralLenses for focusing the optical lever laser (Re:divergence of He Ne 1035P)Steve had difficulty in finding lenses for
focusing the HeNe laser for the ITM op-lev.
Following his measurement of the beam divergence,
 BeamProfile.pngBeamPropagation.pngBeamPropagation.zip 
  1072   Thu Oct 23 15:27:19 2008 AlbertoUpdateGeneralAbs lengthHere are the measurements I've got yesterday.
The plot shows the transmitted power after
the X arm while sweeping the frequency of
 TRX_aplot_03_04_05_together.png 
  1073   Thu Oct 23 18:23:47 2008 AlbertoUpdateGeneralAbs length[quote]Here are the measurements I've got
yesterday. The plot shows the transmitted
power after the X arm while sweeping the
 TRX_plot_06_07_08_together.png 
  1074   Thu Oct 23 18:27:04 2008 AlbertoUpdateGeneralAbs length[quote]Here are the measurements I've got
yesterday. The plot shows the transmitted
power after the X arm while sweeping the
 HOM_Frequencies.m 
  1084   Fri Oct 24 11:42:48 2008 AlbertoUpdateGeneralAbs length: locking the X arm cavity in TEM01/10I went back to lock the arm cavity in either
TEM01 or TEM10 mode. Attached are the results.
We still have several resonances which we
 TRX_armTEM00-plot_09-10_together.png 
  1086   Fri Oct 24 17:21:13 2008 AlbertoUpdateGeneralAbs length: the right amount of beam clippingI found the reason why the peak at about 6.3MHz
appeared only on the TEM10 mode: the blade
was clipping the beam too much and it was
 24OCT08_levels_of_clipping_comparison.png 
  1087   Fri Oct 24 18:05:01 2008 AlbertoUpdateGeneralAbs length: transverse mode spacing measured for the X armThe ETMX suffers of astigmatism. I measured
the following frequencies for the higher
order modes:
 24OCT08_TEM10-01_comparison(file12-14).png 
  1108   Mon Nov 3 19:12:27 2008 albertoUpdateGeneralTransverse mode spacing measurement for the X armI know a lot of expectations have been building
up on these days in the scientific community
at the 40m towards a conclusive elog entry
 2008-11-02_summarizingplot.png 
  1109   Mon Nov 3 19:18:47 2008 AlbertoConfigurationGeneralnew elogPhil Ehrens kindly poured our elog's content
in a CD that now is here at the 40m.
I've been trying to install the 2.7.5 version
  
  1110   Mon Nov 3 21:38:32 2008 YoichiConfigurationGeneralnew elog[quote]I tried to recompile the elog from
the source code but the way gcc is called
must be wrong because I get this error message:
  
ELOG V3.1.3-