Entry  Sun Jul 25 18:47:23 2010, Alberto, Update, SVN, Optickle 40mUpgrade model updated to include short cavity length corrections 
I uploaded an updated optickle model of the upgrade to the SVN directory with the optickle models (here).
    Reply  Mon Jul 26 08:51:31 2010, steve, Update, PEM, lowering AC setpoint by 2F makes PSL happy htempRTemp.jpg


    
        
            Quote:
        
        
            
            The control room temp is warmer than usual. The heat exchanger Office Pro 18 set point was lowered from 70 to 68F
    Reply  Mon Jul 26 10:02:42 2010, josephb, Update, CDS, Rerouted RFM around c1lsc, took RFM card out of c1lsc 
If you're refering to just the medm screen,  those can be restored from the SVN.  As we're moving to a new directory structure, starting with
/opt/rtcds/caltech/c1/, the old LSC screens can all be put back in the /cvs/cds/caltech/medm/c1/lsc directory if desired.
The slow lsc aux crate, c1iscaux2, is still working, and those channels are still available.  I confirmed that one was still updating. As
    Reply  Mon Jul 26 10:04:24 2010, steve, Update, General, Initial Crane Inspection reveals flaws: wiring, oil and imbalance 2500.JPGsedrum.JPG


    
        
            Quote:
        
        
            
            The guy from KroneCrane (sp?) came today and started the crane inspection on the X End Crane. There were issues with
Entry  Mon Jul 26 12:31:36 2010, kiwamu, Update, CDS, front end machine for the X end 
A brief report about the new front end machine "C1ISCEX" installed on the X end (old Y end).
Still the DAC is not working.
 
-
Entry  Mon Jul 26 14:24:46 2010, josephb, kiwamu, Update, CDS, RFM test take 1 
Kiwamu and I strung a temporary RFM fiber from the c1iscex machine (in the new 1X9 rack) to the c1sus machine (in the new 1X4 rack).  This was connected
into the respective RFM cards.  Once we put the fiber in correctly, the status lights came on the RFM card, which is a good sign.  This did not
go through the RFM bypass, and did not interfere with any other RFM connections.
Entry  Mon Jul 26 20:12:18 2010, kiwamu, Update, SUS, OSEMs on PRM DSC_2279.JPG
 [Alberto and Kiwamu]
We installed the OSEMs to the new PRM.
As I wrote down on the elog (
Entry  Mon Jul 26 20:30:35 2010, Jenne, Update, SUS, 2 Tip Tilts suspended and balanced 
[Koji, Jenne]
We were on Team Cleanroom, while Kiwamu and Alberto were on Team Chamber.  Team Cleanroom suspended and
balanced 2 Tip Tilts this afternoon.
Entry  Tue Jul 27 11:43:24 2010, steve, Update, PEM, air quality is bad today pemtoday.jpg
The lab is at 30,000 and Pasadena air is at 1.1 e+6 particles /cf min of 0.5 micron.
Entry  Tue Jul 27 12:02:31 2010, Gopal, Update, Optic Stacks, Preliminary Transfer Function Measurements on MC1/MC3 MC1_MC3_FDA_1.pngMC1_MC3_FDA_2.pngMC1_MC3_FDA_3.pngMC1_MC3_FDA_4.pngMC1_MC3_FDA_5.png
I have successfully completed a preliminary transfer function measurement
test on the MC1/MC3 stack in COMSOL. Using the measurement scheme described on the Wiki, I initialized a 1 N/m^2 sinusoidal perturbation on the bottom
of the stack and measured the maximum displacement of the top layer. This preliminary test just calculated the responses to 1-,2-,3-,4-, and 5-Hz drives
Entry  Tue Jul 27 18:42:57 2010, Gopal, Update, Optic Stacks, Bode Magnitude Plot and Concerns Bode_Mag_MC1_MC3.png
I  completed the frequency domain analysis mentioned previously in the  x-direction.
Although I ran it from 1-10 Hz, with 0.1-Hz increments,  COMSOL was unable to complete the task past 7 Hz because the relative  error was beyond
the relative tolerance. To solve this issue, I'd have  to rerun the simulation with a finer mesh, an unfavorable option because  of the already-extensive
    Reply  Tue Jul 27 21:38:21 2010, kiwamu, Update, SUS, installation of in-vac optics DSC_2284.JPGDSC_2291.JPG
[Alberto and Kiwamu] 
We put the PRM back approximately on the right place.
Also we installed the pick off mirrors and the PZT mirror.
Entry  Tue Jul 27 23:46:45 2010, Jenne, Update, SUS, Q measurements of 2 TTs 
[Koji, Jenne]
We took measurements of the Q of all the modes that we could think of for TT#4, and then repeated several of the same measurements for TT#2. 
We noticed that when we took off the backplane and then replaced it on TT#4, the pitch pointing had changed, so we had to repeat the balancing procedure
    Reply  Wed Jul 28 01:05:44 2010, rana, Update, SEI, Bode Magnitude Plot and Concerns 
1) Gravity has to be included because the inverted pendulum effect changes the resonant frequencies. The deflection from gravity is tiny but the change
in the dynamics is not. The results are not accurate without it. The z-direction probably is unaffected by gravity, but the tilt modes really feel it.
2) You should try a better meshing. Right now COMSOL is calculating a lot of strain/stress in the steel plates. For our purposes, we can imagine
Entry  Wed Jul 28 12:09:06 2010, Sharmila,Katharine, Update, WIKI-40M Update, Maglev Picture_1.png
We have modeled our maglev setup in simulink but we have a few corrections to make since the system goes into undamped oscillations for an impulse in
the input.
We have made a stable mount for the system and started to work on the 2X2 system using this mount. We have to figure out a way to match the magnets
    Reply  Wed Jul 28 12:16:03 2010, Gopal, Update, SEI, Bode Magnitude Plot and Concerns Bode_Disp_MC1_MC3_y.png


    
        
            Quote:
        
        
            
            1) Gravity has to be included because the inverted pendulum effect changes the resonant frequencies. The deflection
Entry  Wed Jul 28 12:31:00 2010, Gopal, Update, WIKI-40M Update, 7.21.10-7.28.10 Weekly Update 
Summary of this week's activities:
7/21: Frequency Domain Analysis of rectangular bar; discussed with Koji how to convert complex eigenfrequencies into phase factors.
7/23: Created Wiki page about FDA; Journal Club
Entry  Wed Jul 28 12:53:32 2010, channa, Update, Computers, nds data listener 
For the sake of writing it down: /cvs/cds/caltech/apps/linux64/rockNDS
Entry  Wed Jul 28 13:06:47 2010, Razib, Update, Phase Camera,  mean_100_snaps.pngstd_100_snaps.pngphase_cam_calc.pdf
Attached are some calculation that I did previously for the phasecamera setup. This shows the nature of the beat signal that we are measuring.
I am also trying to characterize the noise source of the camera also. Following images shows the mean dark noise (with no light on the camera)
and the standard deviation for 100 snaps at an exposure time of 500 µs.
Entry  Wed Jul 28 14:34:29 2010, channa, Update, Computers, installation on allegra 
I have done the following on allegra and rosalba:
[root@allegra caltech]# yum install glade2
On rosalba the matplotlib was out of date with respect to allegra.  I have no idea how the version 0.98 on allegra got there, but I left it. 
Entry  Wed Jul 28 14:54:56 2010, steve, Update, SAFETY, evacuation drill at the 40m P1060520.JPG
Head count at the evacuation drill today. I checked  alarms and flashers  at room 104,102,101, 103, 105 and 107. They were really loud and
bright. 
    Reply  Wed Jul 28 16:42:21 2010, steve, Update, General, Crane gear box cheched P1060503.JPGP1060511.JPGP1060515.JPGP1060517.JPG


    
        
            Quote:
        
        
            
            
            
    
    Reply  Wed Jul 28 17:32:37 2010, kiwamu, Update, SUS, installation of in-vac optics 
[Jenne, Koji and Kiwamu]
We have installed two steering mirrors and the green periscope.
Also we took the tip-tilt out from the chamber for characterization
Entry  Wed Jul 28 18:24:57 2010, Jenne, Update, Green Locking, 2 Green Periscopes have mirrors, aligned 
[Koji, Jenne, Kiwamu]
This is to describe the work that went on in the Cleanroom today.  Kiwamu's entry will detail the tidbits that happened in the chamber.
We engraved the periscope mounts with the mirror info for the mirrors which were placed in the periscope.  We also engraved the barrels of
    Reply  Thu Jul 29 10:39:43 2010, kiwamu, Update, SUS, Re: installation of in-vac optics 
I updated the
last entry about the in-vac work (see here)
Entry  Thu Jul 29 11:33:38 2010, kiwamu, Update, CDS, PCI5565 driver for RFM 
 Yesterday I installed a PCI-5565 driver on new C1SUS in order to test the RFM.
Since the
RFM on the new CDS is not working, we had to test it by using some softwares.

Entry  Thu Jul 29 12:31:24 2010, josephb, Update, CDS, Working DAC, working IOP - next up SUS Simple_Green_Control.png
Ok, after a few minutes of talking to Alex, I got the correct "GUI syntax" through my head, and we now have a simple working green end control
which in fact puts signals out through the DAC.
Note to self, do not put any additional filters or controls in the IOP module.  Basically just change the master block with GDS numbers, DCU_ID
Entry  Thu Jul 29 15:35:21 2010, josephb, kiwamu, Update, CDS, Working out ADC/DAC/BO wiring 
We are currently using the SUS wiring diagram found on Ben Abbott's page (link here) to determine
the ADC/DAC/BO channel numbers for each individual optics inputs and outputs.  Basically it involves tracking the paths back from the Pentek's, XY220,
and IC110Bs to a point where we can identify it as a Coil UL or a PD whitening filter control or whatever it might be.
Entry  Thu Jul 29 17:11:16 2010, Gopal, Update, COMSOL Tips, Including Gravity in COMSOL 
[Gopal, Jan]
For the past couple of days, Jan and I have been discussing a major issue in
COMSOL involving modeling both oscillatory and non-oscillatory forces simultaneously while using FDA. It turns out that he and I had run into the
    Reply  Thu Jul 29 17:12:48 2010, josephb, kiwamu, Update, CDS, Re:Working out ADC/DAC/BO wiring DSC_2302.png
We have installed  4 BO boards, 3 DAC boards and 1 ADC board for new C1SUS.
They are on
the 1Y5 rack. 
 
 
    Reply  Thu Jul 29 21:13:39 2010, Dmass, Update, Green Locking, waist positon of Gaussian beam in PPKTP crystals 


    
        
            Quote:
        
        
            
            The mode profile of Gaussian beams in our PPKTP crystals was calculated.
Entry  Thu Jul 29 22:08:32 2010, Alberto, Update, SUS, More optics installed on the BS table 
[Koji, Steve, Kiwamu, Alberto]
- This afternoon we installed a few new optics on the BS table: GR_PBS, GRY_SM2, GRY_SM1.
- We pulled up the cables so that we had more freedom to move one of the cable towers farther South.
    Reply  Thu Jul 29 22:58:25 2010, kiwamu, Update, Green Locking, waist positon of Gaussian beam in PPKTP crystals 
- As you said, I just calculated the waist position in the crystal because the speed of light changes in a medium and eventually the waist position also
changes.
- Yes, I did. Once you get a beam with the right waist size, you just put your crystal at the waist position with the offset.
    Reply  Fri Jul 30 00:02:15 2010, Dmass, Update, Green Locking, waist positon of Gaussian beam in PPKTP crystals 


    
        
            Quote:
        
        
            
            - As you said, I just calculated the waist position in the crystal because the speed of light changes in a medium and
    Reply  Fri Jul 30 02:54:04 2010, Koji, Update, 40m Upgrading, More optics installed on the BS table 
July 29 Thu [Steve, Alberto, Kiwamu, Koji]
We placed some optics in the BS chamber.
The chambers are ready to be pumped down on Friday once the heavy door is placed.
    Reply  Fri Jul 30 09:51:58 2010, kiwamu, Update, Green Locking, Re: waist positon of Gaussian beam in PPKTP crystals efficiency_waist_edit.pngPPKTPmode.pngPSL_doubling.pngmode_in_PPKTP.png
Okay, I guess I understand what you want to know. I did the following steps.
1. calculated the conversion efficiency as a function of the waist size. I found w~50um was the optimum waist.

    Reply  Fri Jul 30 14:53:09 2010, steve, Update, General, PSL table leg upgrade psllegs.PDF


    
        
            Quote:
        
        
            
            July 
Entry  Fri Jul 30 17:24:22 2010, Jenne, Update, PEM, Guralps back in the 40m 
I brought the GUR2 seismometer back from Bridge so I can get some more MC/Seismic data during the next week while we're pumped down, before we start
doing things to the PSL table.  Both of the Gur Seismometers are connected back up to the breakout box as of ~3:27pm today.  Alastair still has
the handheld controller thing (which I use for mass centering, on occasion), since he'll want the seismometer back in a week or two when I'm done with
    Reply  Sat Jul 31 10:12:05 2010, kiwamu, Update, VAC, Re: How to stop and start slow pumpdown 
I resumed the pumping down. It started from 9:55 am.
    Reply  Sat Jul 31 14:59:33 2010, kiwamu, Update, VAC, Re: How to stop and start slow pumpdown 
I stopped the pumping at 14:50 pm because I was going back home. I did the same procedure as Koji
wrote down (see here).
The P1 pressure reached 32 Torr.
Entry  Sat Jul 31 17:37:36 2010, josephb, Update, CDS, Cables needed for CDS test 
Last Thursday, Kiwamu and I went through the cabling necessary for a full damping test of the vertex optics controled by the sus subsytem, i.e. BS, ITMX,
ITMY, PRM, SRM.  The sus IO chassis is sitting in the middle of the 1X4 rack.  The c1sus computer is the top 1U computer in that rack.
ADCs:
The hardest part is placing the 2x D-sub connectors to scsi on the lemo break out boxes connected to the 110Bs.  The breakout
Entry  Sat Jul 31 22:35:01 2010, Koji, Update, VAC, Vac-P1 still 1.2mtorr 
I resumed the pumping from 19:00.
Now the valve RV1 is full open. But the pumping is really slow as we are using only one RP.
After 3hrs of pumping, P1 reached 1.2mmtorr but still we need 2hrs of pumping...
    Reply  Sun Aug 1 18:50:35 2010, Koji, Update, VAC, P1 = 0.48 torr 
I resumed the pumping today. Now the pressure is 0.48 torr. The pump was stopped.


    
        
            Quote:
        
        
            
Entry  Mon Aug 2 17:12:28 2010, Koji, Update, General, Lab schedule for the week of Aug. 2 PSL_work_schedule.pdf
Aug
2 Mon - 5 Thu WFS work (Nancy)
Entry  Mon Aug 2 18:02:46 2010, Jenne, Update, PEM, Seismometer Update: Still not good, but perhpas getting better 
Today's seismometer diagnosis activities are still underway, this is just an update (since I did some reboots):
Problem 1: X and Z channels on both seismometers were flipped.  I unplugged an X cable (East/West on the cable labels) and the Z channel (vert)
would go to floating ADC zero.  Rana suggested that the ADCs sometimes have random channel hopping, and that a reboot of the c0dcu1 computer which
Entry  Mon Aug 2 21:52:57 2010, Koji, Update, IOO, MC is running at the full power 
[Nancy and Koji]
We restored the full power operation of the MC.
Restoration of the suspensions
    Reply  Tue Aug 3 01:51:01 2010, Jenne, Update, PEM, Seismometer Update: Still not good, but perhaps getting better 


    
        
            Quote:
        
        
            
            Today's seismometer diagnosis activities are still underway, this is just an update (since I did some reboots):
Entry  Tue Aug 3 03:15:06 2010, nancy, Update, IOO, MC back to locked mode 
I turned the WFS gain to 0.02 back, and the MC is locked, the data for the seismic motion might be meaningful nowforth.
    Reply  Tue Aug 3 11:17:10 2010, kiwamu, Update, CDS, Diagrams for Cables needed for CDS test sus_wiring.pngsus_new_wiring.pngsus_missing_stuff.png
Current Wiring Setup for the Suspension Controls
Entry  Tue Aug 3 11:50:16 2010, Jenne, Update, PEM, Seismometer Problem Tracked down 
After some cable swapping this morning, I have determined which cable is bad.  It's the Gur1 cable between the seismometer and the breakout
box.  This is a milspec -> 37pin d-sub cable.  I'll pull out the cable and have a look at it after lunch.