Entry  Tue Nov 30 12:10:44 2010, josephb, Update, elog, Elog restarted again 
The elog seemed to be down at around 12:05pm.  I waited a few minutes to see if the browser would connect, but
it did not.
I used the existing script in /cvs/cds/caltech/elog/ (as opposed to Zach's new on in elog/elog-2.8.0/) which also
Entry  Tue Nov 30 11:44:36 2010, Zach, Update, elog, elog restarted -- SCRIPT adapted for 2.8.0 
 I have created an updated version of the "start-elog-nodus" script and put it in .../elog/elog-2.8.0. It
seems to work fine.
Entry  Mon Nov 29 22:50:07 2010, Suresh, Update, SUS, ETMU05 Side Magnets glued back  
[Suresh, Jenne]
ETMU05 : Gluing Side magnets back on to the optic.
The following steps taken in this process:
Entry  Mon Nov 29 18:05:17 2010, Leo Singer, Configuration, Computers, installed graphviz on Rosalba 
I installed the following packages on Graphviz in order to support visualization of GStreamer pipeline graphs:
graphviz
Entry  Mon Nov 29 17:45:28 2010, Zach, Update, elog, restarted elog 
 The elog was down so I restarted it. The instructions on the wiki do not work as the process has some complicated name (i.e. it is not just 'elogd').
I used kill and the pid number.
I will get around to updating the restart script to work with 2.8.0.
Entry  Fri Nov 26 16:37:29 2010, kiwamu, Update, Photos, pictures on PIcasa DSC_2657_ss.jpg
 I uploaded some pictures taken in the last and this week. They are on the Picasa web albums.
 in
vac work [Nov. 18 2010]
Entry  Tue Nov 23 23:13:40 2010, kiwamu, Summary, CDS, plan: we will install C1LSC 
 [Joe, Suresh, Kiwamu]
 We will fully install and run the new C1LSC front end machine
tomorrow.
    Reply  Thu Nov 25 02:49:39 2010, kiwamu, Update, CDS, installation of C1LSC: still going on DSC_2723_ss.jpgDSC_2724_ss.jpgDSC_2727_ss.jpg
 [Joe, Kiwamu]
 We tried installing C1LSC but it's not completely done yet due to the following issues.
    (1)  A PCIe optical fiber which is supposed to connect C1LSC and its IO chasis is broken at a high probability.
Entry  Wed Nov 24 18:11:26 2010, Jenne, Update, PEM, Some progress on getting PEM channels 
I have made a little bit of progress on the PEM channels.  I have begun writing up detailed instructions in the
DAQ Wiki page on how to add a channel to the new DAQ system.  I have followed those instructions thus far, and can see my channels in the .ini
file (and in the daqconfig gui thing), but I don't have any channels in Dataviewer or DTT.  
Entry  Wed Nov 24 17:57:24 2010, Jenne, Update, SUS, ETMU07: Baking. ETMU05: Needs side magnets reglued StatusTable.png
[Jenne, Koji]
We removed ETMU07 from the suspension tower, after confirming that the balance was still good.  Bob put it in the oven to bake over the weekend. 
The spring plungers and our spare magnets are all in there as well. 
Entry  Tue Nov 23 16:55:14 2010, josephb, Update, CDS, Updated apps 
Updated Apps:
I created a new setup script for the newest build
of the gds tools (DTT, foton, etc), located in /opt/apps (which is a soft link from /cvs/cds/apps) called gds-env.csh.
This script is now sourced by cshrc.40m for linux 64 bit machines.  In addition, the control room machines
    Reply  Tue Nov 23 23:52:49 2010, rana, Update, CDS, Updated apps 
Wow. I typed DTT on rossa and it actually worked! No complaints about testpoints, etc. I was also able to use its new 'NDS2' function to get data
off of the CIT cluster (L1:DARM_ERR from February). You have to use the kinit/kdestroy stuff to use NDS2 as usual (look up NDS2 in DASWG if you don't know
what I mean). 
Entry  Tue Nov 23 22:45:59 2010, kiwamu, Update, Computers, Altium 
I installed and activated Altium, a PCB design software, on the Windows machine
M2.
With Altium I am going to design the triple resonant circuit for the
Entry  Tue Nov 23 18:08:28 2010, Jenne, Update, SUS, ETMU07: Balanced, standoff glued. ETMU05: Magnets glued to optic StatusTable.png
[Koji, Jenne]
ETMU07 had its wire winched to the correct height, was balanced, standoff glued.  Can be ready for going into the oven tomorrow, if an oven
is available.  (One of Bob's ovens has a leak, so he's down an oven, which puts everything behind schedule.  We may not be able to get anything
Entry  Tue Nov 23 14:52:28 2010, Jenne, Update, PEM, PEM Model Started 
Joe showed me what was what with adding DAQ channels, and I have begun building a simulink model to acquire
the PEM channels.  
My models is in: /cvs/cds/rtcds/caltech/c1/core/advLigoRTS/src/epics/simLink/c1pem.mdl
Entry  Tue Nov 23 11:32:03 2010, Joonho, Summary, Electronics, RF distribution unit. Frequency_Distribution_Unit_Arrangement.jpg
The last time(Friday) I made an arrangement for RF distribution unit.
I am making RF distribution unit for RF upgrade which is designed by Alberto.
 
Entry  Tue Nov 23 11:20:30 2010, josephb, Update, CDS, Cleaning up old target directory 
Winter Cleaning:
I cleaned up the /cvs/cds/caltech/target/ directory of all the random models we had built
over the last year, in preparation for the move of the old /cvs/cds/caltech/target slow control machine code into the new /opt/rtcds/caltech/c1/target
directories.
Entry  Tue Nov 23 10:53:20 2010, josephb, Update, CDS, timing issues 
Problem:
Front ends seem to be experiencing a timing issue. 
I can visibly see a difference in the GPS time ticks between models running on c1ioo and c1sus. 
 In addition, the fb is reporting a 0x2bad to all front ends.  The 0x2000 means a mismatch in config files,
Entry  Mon Nov 22 20:31:58 2010, kiwamu, Update, Green Locking, searching for unknown loss in green PD path RFPDresponse.png
 As I said in the past entry (see this entry), there was unknown loss of about 20dB in
the beat detection path.
So I started fully characterizing the beat detection path. 
    Reply  Tue Nov 23 01:45:47 2010, kiwamu, Update, Green Locking, noise curve of wideband RFPD noise_RFPD.png


    
        
            Quote: #3970
        
        
            

           So I started fully characterizing the beat detection path. 
Entry  Tue Nov 23 01:27:33 2010, Kevin, Update, Electronics, POX Characterizations 
I measured the RF transimpedance of the POX photodiode by measuring the optical transfer function with the AM laser and by measuring the shot noise with
a light bulb. The plots of these measurements are at http://lhocds.ligo-wa.caltech.edu:8000/40m/Electronics/POX.
I measured the noise of the photodiode at 11 MHz for different light intensities using an Agilent 4395a. The noise of a 50 ohm resistor as measured
Entry  Mon Nov 22 20:01:56 2010, kiwamu, Configuration, Computers, GPIB box : took it out from HP3563A and connect it to AG4395A 
 I disconnected the yellow GPIB box from the backside of HP3563A (classic analyzer),
 and connected it to AG4395A (network analyzer), which is the official place for it.
Entry  Mon Nov 22 18:39:53 2010, Jenne, Update, SUS, ETMU07: magnets glued to optic. ETMU05: magnets removed StatusTable.png
[Suresh, Jenne]
A story about minor disasters, and crises averted:
Once upon a time, in a cleanroom not so far away..... there lived an optic.  To preserve anonymity, we shall call him "ETMU05". 
Entry  Mon Nov 22 17:48:11 2010, josephb, Update, CDS, c1iscex is not seeing its Binary Output card 
Problem:
c1iscex does not even see its 32 channel Binary output card.  This means we have no control
over the state of the analog whitening and dewhitening filters.  The ADC, DAC, and the 1616 Binary Input/Output cards are recognized and working.
Things tried:
Tried recreating the IOP code from the known working c1x02 (from the c1sus front end),
Entry  Mon Nov 22 16:16:04 2010, josephb, Update, CDS, Did an SVN update on the CDS code 
Problem:
The CDS oscillator part doesn't work inside subsystems.
Solution:
Rolf checked in an older version of the CDS oscillator which includes an input (which you
just connect to a ground).  This makes the parser work properly so you can build with the oscillator in a subsystem.
Entry  Mon Nov 22 13:16:52 2010, josephb, Summary, CDS, CDS Plan for the week 
CDS Objectives for the Week:
Monday/Tuesday:
1) Investigate ETMX SD sensor problems
2) Fully check out the ETMX suspension and get that to a "green" state.
Entry  Fri Nov 19 17:12:22 2010, yuta, Update, CDS, ETMX damped, but with weird TO_COIL matrix ETMXdamping.png
Background:
  c1iscex machine is currently being setup and RT model c1scx is running.
  But ETMX(south) didn't seem to be damped, so I checked it.
    Reply  Mon Nov 22 12:00:18 2010, josephb, Update, CDS, Updated Computer Restart Procedures for FB 
I've updated the  Computer Restart Procedures 
page in the wiki with the latest fb restart procedure.
To just restart just the daqd (frame builder) process, do:
Entry  Sat Oct 30 05:27:53 2010, yuta, Summary, CDS, CDS time delay measurement delaysetup.pngCDSdelay.png
Motivation:
  We want to know the time delay of CDS in the IOP scheme.
    Reply  Sat Oct 30 14:35:43 2010, Koji, Summary, CDS, CDS time delay measurement CDS_system_investigation_090323.pdf
Unsatisfactory.
Neglecting the digital anti-imaging filter makes the discrepancy. You must take into account your digital filter twice.
I attached the slides I made during my visit for March LVC '09. P.5 would be useful.
       Reply  Mon Nov 1 15:47:15 2010, yuta, Summary, CDS, CDS time delay measurement downupsampling.pngCDSdelay2.png
Background:
  I measured CDS time delay last week, but because of my lack of understanding the system, it was incorrect.
  IOP has an anti-aliasing filter before downsampling from 64kHz(65536Hz) to 16kHz(16384Hz) and also has an anti-imaging filter before upsampling
          Reply  Mon Nov 1 16:43:24 2010, Koji, Summary, CDS, CDS time delay measurement 
Um, Beautiful.
Actually, 123.5usec is almost exactly twice of 1/16384Hz. 
Because of the loop, we have 1/16384Hz delay. I wonder where we do have the delay.
             Reply  Sat Nov 20 03:37:11 2010, yuta, Summary, CDS, CDS time delay measurement - the ripple c1tst16Kdelay.png
(Koji, Joe, Yuta)

Motivation:
Entry  Sat Nov 20 02:25:30 2010, yuta, Update, CDS, 2 LOCKINs for suspension models LockinRoll.png
(Suresh, Koji, Yuta)

Background:
Entry  Sat Nov 20 01:58:56 2010, yuta, HowTo, CDS, editting RT models and MEDM screens 
(Suresh, Yuta)

If you come up with a good idea and want to add new things to current RT model;
Entry  Fri Nov 19 18:20:59 2010, Suresh, Update, SUS, Glue dynamics! Too_much_glue_1.jpgToo_much_glue_2.jpgToo_much_glue_2.jpgToo_much_glue_3.jpg
I examined the magnet-dumbbell joints under the microscope to see whether the glue that I applied yesterday was sufficient
or in excess.
I think the pictures below speak for themselves !   
Entry  Fri Nov 19 16:13:09 2010, Jenne, Update, SUS, ETMU05: magnets glued to optic StatusTable.png
[Jenne, Suresh]
Suresh and I glued the intact-from-the-first-round magnets to ETMU05.  I accidentally got too much
glue on one of the dumbbells (the glue was connecting the dumbbell to the gripper - bad news if we let that dry), and while I was cleaning it, the magnet
Entry  Fri Nov 19 03:43:33 2010, Kevin, Update, Electronics, REFL55 Characterizations 
[Koji, Rana, and Kevin]
I have been trying to measure the shot noise of REFL55 by shining a light bulb on the photodiode and measuring the noise with a spectrum analyzer.
The measured dark noise of REFL55 is 35 nV/rtHz. I have been able to get 4 mA of DC current on the photodiode but have not been able to see any shot noise.
    Reply  Fri Nov 19 15:51:50 2010, Koji, Update, Electronics, REFL55 Characterizations 
RF Transimpedance of 200Ohm means the residual impedance at the resonance (R_res) of 40, 
if you consider the amplifier gain (G_amp) of 10 and the voltage division by the 50Ohm termination, 
this corresponds to the thermal noise level of Sqrt(4 kB T R_res)*G_amp/2 = 4nV/rtHz at the analyzer, while you observed 35nV/rtHz.
Entry  Fri Nov 19 12:53:50 2010, josephb, Update, CDS, Testpoints on c1iscex now working 
Problem:
c1iscex did not have test points working last night.
Solution:
The diag -i command indicated that :
awg 19 0 192.168.113.80 822095891 1 192.168.113.80
Entry  Fri Nov 19 04:23:12 2010, Suresh, Update, SUS, Cleaned and stuck magnets to dumbbells 7x
To clean the glue off the magnets and dumbbells I soaked them in Acetone for
about an hour and then scrubbed the ends clean with a lint free tissue soaked in Acetone. 
 I then examined the ends under a microscope and found that while the flat faces were clean some of the grooves
Entry  Thu Nov 18 23:45:18 2010, rana, Configuration, PSL, PMC Refl Cam mc2_simulink.png
Valera and Haixing and I installed a PMC REFL camera today.
We stole the camera control box from the MC2 trans area (because I don't know why we need a camera there).
We installed it such that it is looking at the leak through of the last turning mirror before the PMC REFL RFPD. This beam was previously going
Entry  Thu Nov 18 17:42:20 2010, Joonho Lee, Summary, Electronics, CCD cables. Upgrade_plan_(Nov18).pdf
I finished the direct measurement of cable impedances.
Moreover, I wrote the cable replacement plan.
The reason I am checking the cables is for replacing the cables with impedance of 50 or 52 ohm by those
Entry  Thu Nov 18 16:42:29 2010, Joonho Lee, Configuration, Electronics, Quad Video for PMCT, RCT, RCR fixed. 
The far right monitor in the control room is now displaying IMCR, PMCT, RCR, RCT.
Please note that top left quad is displying PMCT even if the screen is labeled
with PMCR.
Entry  Thu Nov 18 16:32:21 2010, yuta, Summary, CDS, current damping status for all optics c1sus handles c1susdampings.png
Summary:
   I set Q-values for each ringdown of PRM, BS, ITMX, ITMY, MC1, MC2, MC3 to ~5 using QAdjuster.py.
   Here are the results;
Entry  Thu Nov 18 14:19:01 2010, josephb, Update, CDS, Swapped c1auxex and c1auxey codes 
Problem:
We had not switched the c1aux crates when we renamed the arms, thus the watchdogs labeled
ETMX were really watching ETMY and vice-versa.
Solution:
Entry  Thu Nov 18 14:05:06 2010, josephb, yuta, Update, CDS, c1sus is alive! 
Problem:
We broke c1sus by moving ADC cards around.
Solution:
Entry  Thu Nov 18 11:06:20 2010, josephb, Update, CDS, c1sus and ADCs 
Problem:
ADCs are timing out on c1sus when we have more than 3.
Talked with Rolf:
Entry  Thu Nov 18 01:52:58 2010, Kevin, Update, Electronics, REFL55 Transfer Functions 
I measured the optical and electrical transfer functions for REFL55 and calculated the RF transimpedance. To measure the optical transfer function, I
used the light from an AM laser to simultaneously measure the transfer functions of REFL55 and a New Focus 1611 photodiode. I combined these two transfer
functions to get the RF transimpedance for REFL55. I also measured the electrical transfer function by putting the RF signal from the network analyzer
Entry  Thu Nov 18 00:40:31 2010, yuta, Update, IOO, PRM reflected beam reached AP table 
(Kiwamu, Yuta)

Summary:
Entry  Wed Nov 17 23:45:20 2010, Jenne, Update, SUS, A bad day for suspensions StatusTable.png
[Jenne, Suresh]
Today has been a downright miserable day in the world of suspension work. Thumbs down to that:  
Entry  Wed Nov 17 20:44:59 2010, yuta, Summary, CDS, no QPD channels on c1sus machine today 
(Joe, Suresh, Yuta)

Currently, only 2 ADC cards work on c1sus machine.
Entry  Wed Nov 17 16:02:30 2010, josephb, Update, CDS, Modified feCodeGen.pl to fix filtMuxMatrix name generation 
Problem:
Sometime in the last 3 weeks, probably when Alex brought his latest changes from Hanford to the 40m and did an SVN update, the code which generates
the names of the filter .adl files links for the overall matrix view broke.
Entry  Wed Nov 17 15:49:53 2010, rana, Update, DAQ, Ole Channel Names 
The following channels should be named as below to keep in line with their names pre-upgrade rather than use _DAQ in the name.

    
        
            

           C1:SUS-{OPT}_{POS,PIT,YAW}
Entry  Tue Nov 16 21:42:31 2010, rana, Update, CDS, Screen Time Fix 
I learned today that the following python code will do a find/replace to fix the TIME string on any MEDM screen which has a whited out time field.
Previously,
this field was sourced from the c1dscepics of c1losepics process. Now we have to get it from the IOO or SUS front ends

Here's the python
code:
import
    Reply  Wed Nov 17 10:39:20 2010, josephb, Update, CDS, Screen Time Fix 
An improved python code to apply a replacement to all *.adl files in a directory would be:
import re, os
files = os.listdir("./")
Entry  Wed Nov 17 02:53:41 2010, yuta, Update, IOO, placed new PRM to BS table 
(Kiwamu, Yuta)

Background:
Entry  Tue Nov 16 23:36:29 2010, Suresh, Jenne, Update, SUS, Assembly of ETMs StatusTable.png
[Jenne, Suresh]
 
The ETM assembly has moved forward a couple of steps.  We have completed the following:
Entry  Tue Nov 16 12:47:30 2010, Aidan, Update, Green Locking, PID loop but no green Screenshot-C1LSC_EX_GRN_SLOW.adl.png
The PID loop is ready to be run on the green beat note but, since the tanks are open, there is no green transmission from the end getting to the PSL
table. Nevertheless, here's the screen for the PID loop. The loop script is still in my directory /cvs/cds/caltech/users/abrooks/GRNXSlowServo
The medm screen is attached. It shows the current beat note frequency in MHz ()
    Reply  Tue Nov 16 16:00:26 2010, Aidan, Update, Green Locking, PID loop but no green 


    
        
            Quote:
        
        
            

           RA: All MEDM screens must be in the proper MEDM directory!! Also, all perl scripts must have a .pl extension!!! Also, all scripts must be
Entry  Tue Nov 16 15:32:18 2010, valera, Update, Electronics, OSEM noise at the output of the satellite box osemnoise.pdf
 I measured the SRM OSEM (no magnets at the moment) noise out of the satellite box with a SRS785 spectrum analyzer. I inserted a break out board
into the cable going from the satellite box to the whitening board. The transimpedances of the SRM OSEMs are still 29.2 kOhm. The DC voltages out of the
SRM satellite box are about 1.7 V. The signal was AC coupled using SR560 with two poles at 0.03 Hz and a gain of 10.
ELOG V3.1.3-