40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 113 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  12257   Wed Jul 6 21:05:36 2016 KojiUpdateComputer Scripts / ProgramsNew Tabs and Working Summary PagesI started to receive emails from cron every
15min. Is the email related to this? And
is it normal? I never received these cron
 cron_mail.txt.zip 
  12260   Wed Jul 6 21:50:21 2016 KojiUpdateComputer Scripts / ProgramsNew Tabs and Working Summary PagesIt seemed something has been done. And
I got cron emails.
Then, it seemed something has been
  
  12267   Thu Jul 7 14:45:26 2016 KojiUpdateGeneralpianosa monitor deadJohannes, Koji

We obtained two monitors of the
same type from Larry.
  
  12269   Thu Jul 7 16:05:55 2016 KojiUpdateGeneralSUS VmonAh, thanks. That makes sense. In that case,
we should remove the texts "30Hz HPF"
from the suspension screens.
  
  12272   Fri Jul 8 11:48:09 2016 KojiUpdateGeneralVent progress - ETMX SUS Coil driver electronics investigationYES

Move the suspension on the south
  
  12278   Fri Jul 8 20:44:09 2016 KojiUpdateGeneralETMX removed from suspensionIn the evening, I went into the clean room
to check how it goes.

-
 6x 
  12279   Fri Jul 8 21:02:09 2016 KojiUpdateComputer Scripts / ProgramsMEDM Tab on Summary PagesVery nice!

Some of the screens are up-to-date,
and some are not. Are the errors associated
  
  12293   Tue Jul 12 18:13:19 2016 KojiUpdateVACN2 bottle replacedGautam, Koji

We replaced the right N2 bottle
as it was empty.
  
  12298   Wed Jul 13 03:16:47 2016 KojiUpdateGeneralITMX dustMulticolor flash light:

- It seems that the usb port charging
doesn't work.
  
  12300   Wed Jul 13 21:13:51 2016 KojiUpdateGeneralETMX guide rod gluing / ETMY Magnet gluing[Eric, Koji]


ETMX: The Al guide
rod has been glued on the mirror.
ETMY:
 13x 
  12301   Thu Jul 14 01:00:33 2016 KojiUpdateGeneralETMX ruby guided gluingToday I took the picture of the glued ruby
stand-off. The groove has not been invaded
by the epoxy!
 ruby.jpg 
  12325   Fri Jul 22 03:02:37 2016 KojiUpdateCOCFC painting[Koji Gautam]

We have worked on the FC painting
on ITMX and ITMY. We
 11x 
  12337   Tue Jul 26 14:24:38 2016 KojiSummaryVACPurge compressed air system at LHOI've visited the purge clean
air system at LHO Yarm mid-station with John
Worden.
 12x 
  12339   Tue Jul 26 17:41:59 2016 KojiSummaryVACPurge compressed air systemWe have no number for the CFM without calculation.
We can't assume a random number like
10-15
  
  12354   Fri Jul 29 13:17:34 2016 KojiUpdateGeneralOvenWhile the air bake oven situation is being
improved, how about to buy a cheepo toaster
oven at Target, BestBuy, or anywhere?
  
  12375   Thu Aug 4 17:41:53 2016 KojiUpdateComputer Scripts / ProgramsWeb things mostly back onlineSorry I was writting the elog, but I had
to dive into the chamber (@LHO) before completion.
  
  12376   Thu Aug 4 17:57:09 2016 KojiConfigurationGeneralDon't restart apache2 - nodus /etc/apache2/sites-available/* accidentally deleted Late coming elog about the deletion
of the apahce config files


Thu Aug 4 8:50ish
  
  12378   Fri Aug 5 04:43:09 2016 KojiUpdateSUSETMX Ruby Wire Standoff Ready for GluingIf only the LL magnet looks too low, doesn't
this mean that the OSEMs are not arranged
in a square shape?
  
  12398   Thu Aug 11 00:20:41 2016 KojiUpdateSUSETMY re-suspendedHow much pitch bias do you need in order
to correct this pitch misalignment?
That may give you the idea how bad
  
  12418   Wed Aug 17 16:28:46 2016 KojiUpdateCOCRC folding mirrors - Numerical reviewFor the given range of the PR3/SR3 RoCs
for both cases, all the resulting numbers
such as TMSs/mode matching ratios look reasonable
  
  12435   Tue Aug 23 22:58:16 2016 KojiUpdateElectronicsDecoupling capacitor 101What I suggested was:
- For most cases, power decoupling
capacitors for the regulators should be ~100nF
  
  12438   Wed Aug 24 19:37:55 2016 KojiUpdateElectronicsDecoupling capacitor 101Yes

Interesting articles how they should
only be used for power decoupling and not
  
  12539   Fri Oct 7 20:25:14 2016 KojiUpdateCDSPower-cycled c1psl and c1iool0Found the MC autolocker kept failing, It
turned out that c1iool0 and c1psl went bad
and did not accept the epics commands.
  
  12540   Fri Oct 7 20:56:15 2016 KojiUpdateSUSOutput matrix diagonalizationI wanted to see what is the reason to have
such large coupling between pitch and yaw
motions.
 161007_P.pdf161007_Y.pdf 
  12555   Wed Oct 12 22:51:26 2016 KojiUpdateGeneralClipping could not be improved by the PZTs - NEED ANOTHER VENT[Gautam Koji]

We engaged the HV driver
to the output port PZTs, hoping to mitigate
  
  12558   Thu Oct 13 14:49:57 2016 KojiConfigurationPEMXLR(F)-XLR(M) cable took from the fibox to the Blue microphone[Gautam Koji]

XLR(F)-XLR(M) cable for the blue
microphone is missing. Steve ordered one.
  
  12580   Tue Oct 25 18:07:28 2016 KojiUpdateGeneralPRFPMI locked, arms loss improvedGreat to hear that we have the PRG of ~16
now!

Is this 150ppm an avg loss per
  
  12584   Thu Oct 27 13:48:20 2016 KojiUpdateGeneralPRFPMI locked, arms loss improvedIt is also difficult to have a high arm
transmission without having high PRG.

What about to plot the arm trans
  
  12641   Sat Nov 26 19:16:28 2016 KojiUpdateIOOIMC WFS Demod board measurement & analysis[Rana, Koji]

1. The response of the
IMC WFS board was measured. The
 WFS_demod_response.pdfWFS_demod_noise.pdfWFS_demod_noise_plan.pdfScreen_shot_2011-07-01_at_11.13.01_AM.png 
  12645   Tue Nov 29 17:45:06 2016 KojiUpdateIOOIMC WFS Demod board measurement & analysisSummary: The
demodulator input noise level was improved
by a factor of more than 2. This was
 demod.pdfWFS_demod_response.pdfWFS_demod_noise.pdf 
  12661   Fri Dec 2 18:02:37 2016 KojiUpdateIOOIMC WFS Demod board measurement & analysisELOG of the Wednesday work.

It turned out that the IMC WFS
demod boards have the PCB board that has
 WFS_demod_noise_orig.pdfWFS_demod_noise_mod.pdf 
  12662   Sat Dec 3 13:27:35 2016 KojiUpdateIOOIMC WFS Demod board measurement & analysisELOG of the work on Thursday

Gautam suggested looking at the
preamplifier noise by shorting the input
 WFS_demod_noise.pdfdemod.pdf 
  12668   Tue Dec 6 13:37:02 2016 KojiUpdateIOOIMC WFS Demod board measurement & analysisI have implemented the modification to
the demod boards (Attachment 1).
Now, I am looking at the noise in
 demod.pdfWFS_error_noise.pdf 
  12669   Tue Dec 6 16:47:40 2016 KojiUpdateIOOIMC WFS whitening filter investigationThe
whitening board saids it is Rev B, but the
actual component values are more like Rev.
 D990196-C.pdf 
  12670   Tue Dec 6 17:54:08 2016 KojiUpdateIOOIMC WFS whitening filter investigationThe
input resistor 909Ohm of AD602 was shorted.
I've confirmed that the gain (= attenuation
 34.png 
  12671   Tue Dec 6 22:41:49 2016 KojiUpdateIOOIMC WFS whitening filter investigationI have implemented the same modification
(shorting the input resistor of AD602) to
the two whitening boards.
  
  12676   Tue Dec 13 17:26:42 2016 KojiUpdateIOOIMC WFS whitening filter investigationRana pointed out that this modification
(removal of 900Ohm) leave the input impedance
as low as 100Ohm.
  
  12679   Mon Dec 19 22:05:09 2016 KojiSummaryIOOPMC, IMC aligned. The ringdown PD/Lens removed.PMC and IMC were aligned on Friday (16th)
and Today (19th).

The PD and lens for the ringdown
  
  12680   Wed Dec 21 21:03:06 2016 KojiSummaryIOOIMC WFS tuning- Updated the circuit diagrams:


IMC WFS Demodulator Board, Rev.
 DSC_0142.JPG 
  12682   Thu Dec 22 18:39:09 2016 KojiSummaryIOOIMC WFS tuningNoise analysis of the WFS error signals.

Attachment 1: All error signals
compared with the noise contribution measured
 WFS_error_noise.pdfWFS_error_noise_chans.pdf 
  12683   Fri Dec 23 20:53:44 2016 KojiSummaryIOOIMC WFS tuningWFS1 / WFS2 demod phases and WFS signal
matrix
 DSC_0144.JPGDSC_0145.JPG 
  12684   Fri Dec 23 21:05:56 2016 KojiSummaryIOOIMC WFS tuningSignal transfer function measurements

C1:SUS-MC*_ASCPIT_EXC channels
were excited for swept sine measurements.
 IMC_WFS_segment_TF.pdfIMC_WFS_channels_TF.pdfIMC_WFS_161221_table1.pdfIMC_WFS_161221_table2.pdfIMC_WFS_161221.xlsx.zip 
  12685   Sun Dec 25 14:39:59 2016 KojiSummaryIOOIMC WFS tuningNow, the output matrices in the previous
entry were implemented.
The WFS servo loops have been engaged
  
  12686   Mon Dec 26 12:45:31 2016 KojiSummaryIOOIMC WFS tuningIt didn't go crazy at least for the
past 24hours.
 IMC_REFL_TRANS_26hrs.pngIMC_TRANS_P_Y_26hrs.png 
  12689   Thu Dec 29 16:52:51 2016 KojiSummaryIOOIMC WFS tuningKoji responding to Rana

>
For the rough calibration below 10 Hz, we
  
  12715   Fri Jan 13 21:41:23 2017 KojiUpdateCDSDC errorsI think I fixed the DC error issue

1. I added the leap second
(leapsecond ?) entry for 2016/12/31, 23:60:00
  
  12756   Wed Jan 25 17:30:03 2017 KojiUpdateIMC29.5 MHz modulation depth measurement planI'm afraid that the bidirectional coupler,
designed to be 50ohm in/out, disturbs the
resonant circuit designed for the EOM which
  
  12757   Wed Jan 25 18:18:08 2017 KojiSummaryIOOMCL / MCF / CalibrationjiSome notes on the FSS configuration:
ELOG
10321
  
  12761   Fri Jan 27 15:36:17 2017 KojiUpdateSUS wire standoffs updateVery nice! I got excited.


Don't you ask Calum
and co to check the groove size with their
  
  12783   Wed Feb 1 11:51:19 2017 KojiUpdateIMCRF AM stabilization box pulled outFor a comparison: OMC
ELOG 238
  
ELOG V3.1.3-