  12988   Fri May 12 12:34:55 2017 gautamUpdateGeneralITM and BS coil driver + dewhite board pulled outI first set the bias sliders to 0 on the
MEDM screen (after checking that the nominal
values were stored), then shut down the watchdogs,
  
  12990   Fri May 12 18:50:08 2017 gautamUpdateGeneralITM and BS coil driver + dewhite board pulled outI've uploaded high-res photos + marked
up schematics to the same DCC page linked
in the previous page. I've noted the
  
  13003   Mon May 22 13:37:01 2017 gautamUpdateGeneralDAC noise estimateSummary:

I've
 DAC_noise_model.pdfC1NB_disp_40m_MICH_NB_22_May_2017.pdf 
  13010   Tue May 23 22:58:23 2017 gautamUpdateGeneralDe-Whitening board noisesSummary:

I
 ITMX_deWhite_ch1_noise.pdf 
  13012   Thu May 25 12:22:59 2017 gautamUpdateCDSslow machine bootfestAfter ~3months without any problems on
the slow machine front, I had to reboot 
  
  13015   Thu May 25 19:27:29 2017 gautamUpdateGeneralCoil driver board noises [Koji, Gautam]

Summary: 


Attachment
#1 shows the measured/modeled noise
 coilDriverNoises.pdf 
  13017   Mon May 29 16:47:38 2017 gautamUpdateGeneralCoil driver boards reinstalledYesterday,
I reinstalled the de-whitening boards + coil
driver boards into their respective Eurocrate
 deWhitening_consolidated.pdfdeWhitening_measurements.zipETMY_OL.png 
  13019   Tue May 30 16:02:59 2017 gautamUpdateGeneralCoil driver boards reinstalledI think the reason I am unable to engage
the de-whitening is that the OL loop is injecting
a ton of control noise - see Attachment #1.
 OL_noiseInjection.pdf 
  13026   Thu Jun 1 00:10:15 2017 gautamUpdateGeneralCoil driver boards reinstalled[Koji, Gautam]

We tried to debug the mysterious
sudden failure of ASS - here is a summary
  
  13028   Thu Jun 1 15:37:01 2017 gautamUpdateCDSslow machine bootfestSteve alerted me that the IMC wouldn't
lock. Reboots for
  
  13033   Fri Jun 2 01:22:50 2017 gautamUpdateASSASS restoration workI started by checking if shaking an optic
in pitch really moves it in pitch - i.e.
how much PIT to YAW coupling is there. The
 ASS_Y_recovery.pngASS_Repairs.zipOLs.png 
  13034   Fri Jun 2 12:32:16 2017 gautamUpdateGeneralPower glitchLooks like there was a power glitch at
around 10am today.

All frontends, FB, Megatron, Optimus
  
  13035   Fri Jun 2 16:02:34 2017 gautamUpdateGeneralPower glitchToday's
recovery seems to be a lot more complicated
than usual.


 IMG_7399.JPG 
  13036   Fri Jun 2 22:01:52 2017 gautamUpdateGeneralPower glitch - recovery[Koji, Rana, Gautam]

Attachment #1 - CDS
status at the end of todays efforts. There
 power_glitch_recovery.pngIMG_7406.JPGIMG_7407.JPGIMG_7400.JPG 
  13038   Sun Jun 4 15:59:50 2017 gautamUpdateGeneralPower glitch - recoveryI
think the CDS status is back to normal.


Bit
 powerGlitchRecovery.png 
  13048   Wed Jun 7 14:11:49 2017 gautamUpdateASSY-arm coil driver electronics investigationRana suggested taking a look at the Y-arm
test mass actuator TFs (measured by driving
the coils one at a time, with only local
 CoilTFs.pdfY_OL_calib_check.png 
  13051   Wed Jun 7 17:45:11 2017 gautamUpdateASSY-arm coil driver electronics investigationI repeated the test of driving C1:SUS-<Optic>_<coil>_EXC
individually and measuring
 CoilTFs.pdf 
  13052   Thu Jun 8 02:11:28 2017 gautamUpdateASSY-arm coil driver electronics investigation
p.p1
{margin: 0.0px 0.0px 0.0px 0.0px; font: 18.0px
'Helvetica Neue'; -webkit-text-stroke: #000000}
p.p3
 AnalogCheck.pdfAnalogCheck_zoom.pdfArmCtrl.pdf 
  13055   Fri Jun 9 15:31:45 2017 gautamUpdateIMCIMC wonkinessI've been noticing
some weird behaviour with the IMC over the
 IMG_7409.JPG 
  13058   Fri Jun 9 19:18:10 2017 gautamUpdateIMCIMC wonkinessIt happened again. MC2 UL seems to have
gotten the biggest glitch. It's a rather
small jump in the signal level compared to
 MC2_UL_glitchy.pngMC2_glitch_fast.png 
  13059   Mon Jun 12 10:34:10 2017 gautamUpdateCDSslow machine bootfestReboots for
c1susaux, c1iscaux, c1auxex
  
  13060   Mon Jun 12 17:42:39 2017 gautamUpdateASSETMY Oplev Pentek board pulled outAs part of my Oplev servo investigations,
I have pulled out the Pentek Generic Whitening
board (D020432) from the Y-end electronics
  
  13063   Wed Jun 14 18:15:06 2017 gautamUpdateASSETMY Oplev restoredI
replaced the Pentek Generic Whitening Board
and the Optical Lever PD Interface Board
  
  13064   Thu Jun 15 01:56:50 2017 gautamUpdateASSETMY Oplev restoredSummary:

I tried playing around with
 ITMY_OLspec.pdf 
  13069   Fri Jun 16 13:53:11 2017 gautamUpdateCDSslow machine bootfestReboots for
c1psl, c1iool0, c1iscaux
  
  13079   Sun Jun 25 22:30:57 2017 gautamUpdateGeneralc1iscex timing troublesI saw that the CDS overview screen indicated
problems with c1iscex (also ETMX was erratic).
I took a closer look and thought it might
 c1iscex_status.png 
  13082   Tue Jun 27 16:11:28 2017 gautamUpdateElectronicsCoil whiteningI got back to trying to engage the coil
driver whitening today, the idea being to
try and lock the DRMI in a lower noise configuration
 ETMYT_1182669422.mp4ITMY_whitening_studies.pdf 
  13085   Wed Jun 28 20:15:46 2017 gautamUpdateGeneralc1iscex timing troubles[Koji, gautam]

Here
is a summary of what we did today to fix
 CDS_status_28Jun2017.png 
  13088   Fri Jun 30 02:13:23 2017 gautamUpdateGeneralDRMI locking attemptSummary:

I attempted to re-lock the DRMI
and try and realize some of the noise improvements
 BS_OLmods.pdf 
  13090   Fri Jun 30 11:50:17 2017 gautamUpdateGeneralDRMI locking attemptSeems like the problem is actually with
ITMX
- the attached DV plots are for ITMX with
 ITMX_glitchy.png 
  13093   Fri Jun 30 22:28:27 2017 gautamUpdateGeneralDRMI re-lockedSummary:

Reverted
to old settings, tried to reproduce DRMI
lock with settings as close to those used
 DRMI_relocked.pngMICH_OL.pdf 
  13096   Wed Jul 5 16:09:34 2017 gautamUpdateCDSslow machine bootfestReboots for
c1susaux, c1iscaux
  
  13097   Wed Jul 5 19:10:36 2017 gautamUpdateGeneralNB code checkout - updatedI've been making NBs on my laptop,
thought I would get the copy under version
control up-to-date since I've been negligent
  
  13101   Sat Jul 8 17:09:50 2017 gautamUpdateGeneralETMY TRANS QPD anomalyAbout 2 weeks ago, I noticed some odd behaviour
of the LSC TRY data stream. Its DC value
seems to be drifting ~10x more than TRX.
 ETMY_QPD.pdfETMY_QPD.png 
  13103   Mon Jul 10 09:49:02 2017 gautamUpdateGeneralAll FEs downAttachment #1:
State of CDS overview screen as of 9.30AM
today morning when I came in.
 CDS_down_10Jul2017.png 
  13104   Mon Jul 10 11:20:20 2017 gautamUpdateGeneralAll FEs downI am unable to get FB to reboot to a working
state. A hard reboot throws it into a loop
of "Media Test Failure. Check Cable".
  
  13106   Mon Jul 10 17:46:26 2017 gautamUpdateGeneralAll FEs downA bit more digging on the diagnostics page
of the RAID array reveals that the two power
supplies actually failed on 
  
  13107   Mon Jul 10 19:15:21 2017 gautamUpdateGeneralAll FEs downThe
Jetstor RAID array is back in its nominal
  
  13111   Tue Jul 11 15:03:55 2017 gautamUpdateGeneralAll FEs downJamie suggested verifying that the problem
is indeed with the disk and not with the
controller, so I tried switching the original
  
  13113   Wed Jul 12 10:21:07 2017 gautamUpdateGeneralAll FEs downSeems like the connector on this particular
disk is of the SAS
variety (and not SATA). I'll ask
  
  13114   Wed Jul 12 14:46:09 2017 gautamUpdateGeneralAll FEs downI couldn't find an external docking
setup for this SAS disk, seems
like we need an actual controller in order
  
  13117   Fri Jul 14 17:47:03 2017 gautamUpdateGeneralDisks from LLO have arrived[jamie, gautam]

Today
morning, the disks from LLO arrived. Jamie
and I have been trying to get things back
  
  13120   Sat Jul 15 16:19:00 2017 gautamUpdateCamerasMakeshift PyPylonSome days ago, I stumbled upon
this github page, by a grad student at
KIT who developed this code as he was
 pyPylon_test.png 
  13124   Wed Jul 19 00:59:47 2017 gautamUpdateGeneralFINESSE model of DRMI (no arms)Summary:

I've
been working on improving the 40m FINESSE
model I set up sometime last year (where
 DRMI_sensingMat.pdfDRMI_errSigs.pdf40m_DRMI_FINESSE.zipDRMI_sensingMat_19Jul.pdf 
  13135   Mon Jul 24 10:45:23 2017 gautamUpdateCDSc1iscex models diedThis morning, all the c1iscex
models were dead. Attachment #1
 c1iscexFailure.png 
  13137   Mon Jul 24 12:00:21 2017 gautamUpdatePSLPSL NPRO mysteriously shut offSummary:

At around 10:30AM
 IMG_7454.JPG 
  13139   Mon Jul 24 19:57:54 2017 gautamUpdateCDSIMC locked, Autolocker re-enabledNow that all the front end models are running,
I re-aligned the IMC, locked it manually,
and then tweaked the alignment some more.
  
  13141   Tue Jul 25 02:03:59 2017 gautamUpdateOptical LeversOptical lever tuning thoughtsSummary:

Currently, I am unable to engage
the coil-dewhitening filters without destroying
  
  13146   Thu Jul 27 22:42:24 2017 gautamUpdateSUSSeismic noise, DAC noise, and Coil Driver electronics noiseSummary:

 noiseComparison.pdfdeWhiteConfigs.zipnoiseComparison_resistances.pdf 
  13147   Fri Jul 28 15:36:32 2017 gautamUpdateOptical LeversOptical lever tuning thoughtsAttachment #1 - Measured
error signal spectrum
 errSig.pdfQPD_simulink.pngfeedbackTopology.pdf 
ELOG V3.1.3-