  12661   Fri Dec 2 18:02:37 2016 KojiUpdateIOOIMC WFS Demod board measurement & analysisELOG of the Wednesday work.

It turned out that the IMC WFS
demod boards have the PCB board that has
 WFS_demod_noise_orig.pdfWFS_demod_noise_mod.pdf 
  12662   Sat Dec 3 13:27:35 2016 KojiUpdateIOOIMC WFS Demod board measurement & analysisELOG of the work on Thursday

Gautam suggested looking at the
preamplifier noise by shorting the input
 WFS_demod_noise.pdfdemod.pdf 
  12668   Tue Dec 6 13:37:02 2016 KojiUpdateIOOIMC WFS Demod board measurement & analysisI have implemented the modification to
the demod boards (Attachment 1).
Now, I am looking at the noise in
 demod.pdfWFS_error_noise.pdf 
  12669   Tue Dec 6 16:47:40 2016 KojiUpdateIOOIMC WFS whitening filter investigationThe
whitening board saids it is Rev B, but the
actual component values are more like Rev.
 D990196-C.pdf 
  12670   Tue Dec 6 17:54:08 2016 KojiUpdateIOOIMC WFS whitening filter investigationThe
input resistor 909Ohm of AD602 was shorted.
I've confirmed that the gain (= attenuation
 34.png 
  12671   Tue Dec 6 22:41:49 2016 KojiUpdateIOOIMC WFS whitening filter investigationI have implemented the same modification
(shorting the input resistor of AD602) to
the two whitening boards.
  
  12676   Tue Dec 13 17:26:42 2016 KojiUpdateIOOIMC WFS whitening filter investigationRana pointed out that this modification
(removal of 900Ohm) leave the input impedance
as low as 100Ohm.
  
  12679   Mon Dec 19 22:05:09 2016 KojiSummaryIOOPMC, IMC aligned. The ringdown PD/Lens removed.PMC and IMC were aligned on Friday (16th)
and Today (19th).

The PD and lens for the ringdown
  
  12680   Wed Dec 21 21:03:06 2016 KojiSummaryIOOIMC WFS tuning- Updated the circuit diagrams:


IMC WFS Demodulator Board, Rev.
 DSC_0142.JPG 
  12682   Thu Dec 22 18:39:09 2016 KojiSummaryIOOIMC WFS tuningNoise analysis of the WFS error signals.

Attachment 1: All error signals
compared with the noise contribution measured
 WFS_error_noise.pdfWFS_error_noise_chans.pdf 
  12683   Fri Dec 23 20:53:44 2016 KojiSummaryIOOIMC WFS tuningWFS1 / WFS2 demod phases and WFS signal
matrix
 DSC_0144.JPGDSC_0145.JPG 
  12684   Fri Dec 23 21:05:56 2016 KojiSummaryIOOIMC WFS tuningSignal transfer function measurements

C1:SUS-MC*_ASCPIT_EXC channels
were excited for swept sine measurements.
 IMC_WFS_segment_TF.pdfIMC_WFS_channels_TF.pdfIMC_WFS_161221_table1.pdfIMC_WFS_161221_table2.pdfIMC_WFS_161221.xlsx.zip 
  12685   Sun Dec 25 14:39:59 2016 KojiSummaryIOOIMC WFS tuningNow, the output matrices in the previous
entry were implemented.
The WFS servo loops have been engaged
  
  12686   Mon Dec 26 12:45:31 2016 KojiSummaryIOOIMC WFS tuningIt didn't go crazy at least for the
past 24hours.
 IMC_REFL_TRANS_26hrs.pngIMC_TRANS_P_Y_26hrs.png 
  12689   Thu Dec 29 16:52:51 2016 KojiSummaryIOOIMC WFS tuningKoji responding to Rana

>
For the rough calibration below 10 Hz, we
  
  12715   Fri Jan 13 21:41:23 2017 KojiUpdateCDSDC errorsI think I fixed the DC error issue

1. I added the leap second
(leapsecond ?) entry for 2016/12/31, 23:60:00
  
  12756   Wed Jan 25 17:30:03 2017 KojiUpdateIMC29.5 MHz modulation depth measurement planI'm afraid that the bidirectional coupler,
designed to be 50ohm in/out, disturbs the
resonant circuit designed for the EOM which
  
  12757   Wed Jan 25 18:18:08 2017 KojiSummaryIOOMCL / MCF / CalibrationjiSome notes on the FSS configuration:
ELOG
10321
  
  12761   Fri Jan 27 15:36:17 2017 KojiUpdateSUS wire standoffs updateVery nice! I got excited.


Don't you ask Calum
and co to check the groove size with their
  
  12783   Wed Feb 1 11:51:19 2017 KojiUpdateIMCRF AM stabilization box pulled outFor a comparison: OMC
ELOG 238
  
  12805   Mon Feb 6 18:20:08 2017 KojiUpdateIMCMCL Feedback - simulink model updatedIt is more accurate to model the physical
frequency noises at various places.

cf. See also 40m ALS paper or Shigeo
  
  12821   Fri Feb 10 19:32:15 2017 KojiUpdateIMCIMC Demod boardThe input impedance of the mixer is not
constant. As the diode switches, it changes
dynamically. Because of this, the waveform
  
  12837   Fri Feb 17 20:04:43 2017 KojiUpdateGeneralProjector not functional / Zita partially workingKoji, Gautam, Johannes

We quickly checked the situation
of the projector in the control room.
  
  12846   Thu Feb 23 09:32:20 2017 KojiUpdateSUS wire standoffs updateKyle took high quality images of 
the three sapphire prisms using the microscope
@Downs. He analyzed the images to see the
 Sapphire_prism_1(A015).pngSapphire_prism_2(A016).pngSapphire_prism_3(A014).png 
  12875   Thu Mar 9 15:25:12 2017 KojiUpdateGeneralIMC/XYarms aligned/lockedAs per Steve's request, I've checked
the alignment of the IMC and the arms. These
three cavities are locked and aligned.
  
  12877   Thu Mar 9 20:11:04 2017 KojiUpdateGeneralattempted ETMY picture takingThe attached is the ETMY image with the
single arm locked. This was the best I could
do. Here is the recipe
 P3090032.JPG 
  12912   Mon Mar 27 22:40:44 2017 KojiSummaryIOOMCL / MCF / CalibrationIn http://nodus.ligo.caltech.edu:8080/40m/11793
I posted the calibrated PMC free-running
displcament with/without IMC locked. Unfortunately,
  
  12966   Wed May 3 16:46:18 2017 KojiConfigurationComputerscatastrophic multiple monitor failures- Is there any machine that can handle
4K? I have one 4K LCD for no use.
- I also can donate one 24" Dell
  
  12967   Wed May 3 16:47:45 2017 KojiUpdateGeneralPI pzt inventory checkI also have a functional one on my desk,
which has one of the wires repaired.

  
  12992   Mon May 15 19:21:04 2017 KojiUpdateComputer Scripts / ProgramsFSSslow / MCautolocker restartedIt seems that FSS slow servo stopped working.

I found that megatron was restarted
(
  
  13032   Fri Jun 2 00:54:08 2017 KojiUpdateASSXarm ASS restoration workWhile Gautam is working the restoration
of Yarm ASS, I worked on Xarm.

Basically, I have changed the oscillator
 7x 
  13081   Mon Jun 26 22:01:08 2017 KojiUpdateGeneralc1iscex timing troublesI tried a couple of things, but
no fundamental improvement of the missing
LED light on the timing board.
  
  13094   Sat Jul 1 14:27:00 2017 KojiUpdateGeneralDRMI re-lockedBasically we use the arm cavities as the
reference of the beam alignment. The incident
beam is aligned such that the ITMY angle
  
  13110   Mon Jul 10 22:07:35 2017 KojiUpdateGeneralAll FEs downI think this is the boot disk failure.
I put the spare 2.5 inch disk into the slot
#1. The OK indicator of the disk became solid
  
  13112   Tue Jul 11 15:12:57 2017 KojiUpdateGeneralAll FEs downIf we have a SATA/USB adapter, we can test
if the disk is still responding or not. If
it is still responding, can we probably salvage
  
  13154   Mon Jul 31 20:35:42 2017 KojiSummaryComputersChiara backup situation summarySummary
- CDS Shared files system: backed
up
  
  13159   Wed Aug 2 14:47:20 2017 KojiSummaryComputersChiara backup situation summaryI further made the burt snapshot directories
compressed along with ELOG
11640. This freed up additional ~130GB.
  
  13170   Mon Aug 7 22:50:57 2017 KojiUpdateGeneralNew wifi router for the GC network installedI have replaced the old 11n wifi router
(CISCO / Linksys) for the GC network with
a new one with 11ac technology.
  
  13201   Sun Aug 13 01:35:09 2017 KojiUpdateSUSGlitches stay on MC1We used to have similar suspension excursion
at ETMX. This was the motivation to replace
the stand-offs from Al ones to ruby ones.
  
  13216   Wed Aug 16 17:14:02 2017 KojiUpdateCDSfront-end/DAQ network down for kernel upgrade, and timing errorsWhat's the current backup situation?   
  13218   Wed Aug 16 18:06:01 2017 KojiUpdateCDSfront-end/DAQ network down for kernel upgrade, and timing errorsWe also need to copy chiara's root.
What is the best way to get the full image
of the root FS?
  
  13251   Thu Aug 24 18:51:57 2017 KojiSummaryLSCFirst cavity length reconstruction with a neural networkPhenomenal!
  
  13368   Mon Oct 9 11:55:01 2017 KojiUpdateLSCDRMI Nosie Budget v3.0My last characterization of the AS55 PD
was on Feb 2013. ELOG
8100
  
  13440   Tue Nov 21 17:51:01 2017 KojiConfigurationComputersnodus post OS migration adminThe post OS migration admin for nodusa
bout apache, elogd, svn, iptables, etc can
be found in https://wiki-40m.ligo.caltech.edu/NodusUpgradeNov2017
  
  13449   Wed Nov 22 16:40:00 2017 KojiUpdateOptical LeversOplev "noise budget"You may want to consult with the cryo Q
people (Brittany, Aaron) for a Si QPD. If
you want the same QPD architecture, I can
  
  13462   Sun Dec 3 17:01:08 2017 KojiConfigurationComputerssendmail installed on nodus An email has come at 5PM on Dec 3rd.

 
  
  13465   Thu Dec 7 15:02:37 2017 KojiHowToComputer Scripts / ProgramsLots of red on the FE status screenOnce a realtime machine was rebooted, it
did not come back. I suspect that the diskless
hosts have a difficulty to boot up.
 DSC_0552.JPG 
  13467   Thu Dec 7 16:28:06 2017 KojiUpdateIOOLots of red on the FE status screenOnce the RT machines were back, we launched
only the five IOPs. They had bunch of red
lights, but we continued to run essential
  
  13512   Sun Jan 7 03:22:24 2018 KojiUpdatePonderSqueezeDisplacement requirements for short-term squeezingInteresting. My understanding is that this
is close to signal recycling, rather than
resonant sideband extraction. Is that correct?
  
  13515   Sun Jan 7 20:11:54 2018 KojiUpdatePonderSqueezeDisplacement requirements for short-term squeezingIn fact, that is my point. If we use signal
recycling instead of resonant sideband extraction,
the "tuning" of the SRC is opposite
  
ELOG V3.1.3-