40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 112 of 337  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  5589   Fri Sep 30 18:06:24 2011 kiwamuSummaryIOOPZTs straing guage   beforeOutage110930.png 
  5590   Fri Sep 30 18:35:42 2011 steve, kiwamuUpdateVACvacuum set for poweroutageWe did the following:
1, closed V1, VM1,  annuloses:
VASE, VASV, VABS, VAEV,  VAEE and VA6
 prepforpoweroutage.png 
  5591   Fri Sep 30 19:12:56 2011 KojiUpdateGeneralprep for poweroutage 
 [Koji Jenne]
The lasers were shutdown
  
  5592   Sat Oct 1 17:47:21 2011 KojiSummaryGeneralRecovery from the power shutdown[Steve Koji Kiwamu]
- The storage on linux1 and linux1
itself (with this order) were turned on at
  
  5593   Sat Oct 1 22:53:49 2011 kiwamuSummaryGeneralRecovery from the power shutdown : lockableFound the Marconi for the 11 MHz source
had been reset to its default.
 => reset the parameters.
  
  5594   Sun Oct 2 02:21:27 2011 kiwamuUpdateSUSfree swinging test once moreThe following optics were kicked:
MC1 MC2 MC3 ETMX ETMY ITMX ITMY PRM
SRM BS
  
  5595   Sun Oct 2 02:33:32 2011 kiwamuUpdateLSCsomething funny with AS55Just a quick report.
The AS55
 outofloop.png 
  5596   Sun Oct 2 13:45:13 2011 ranaSummaryGeneralRecovery from the power shutdown: apache / svnRestarted Apache on nodus using Yoichi's
wiki instructions. SVN is back up.
  
  5597   Sun Oct 2 18:33:36 2011 kiwamuUpdateSUSinversion of the input matrix on ETMX, ITMX and PRMThe input
matrices of ETMX, ITMX and PRM have been
 ETMX.pngPRM.pngITMX.png 
  5598   Mon Oct 3 04:43:03 2011 kiwamuUpdateLSCsideband-resonance PRMI lockedMy
goal of today was to lock PRMI without using
AS55 and it is 50% successful.
 ITMYtable.png 
  5599   Mon Oct 3 08:38:21 2011 steveSummaryVACRecovery from the power shutdown is completed 
I failed to start Rana's favorit
anciant desktop computer at the vac rack.
 poweroutage.jpg 
  5600   Mon Oct 3 13:04:12 2011 JenneUpdateSUSAUXEX, AUXEY rebooted


   
        
            
  
  5601   Mon Oct 3 14:05:41 2011 JenneUpdateSUSFailing to set SUS summary screen valuesI assume it's because the burt restore
didn't work for the SUS summary screen, but
all of the values for the ifo suspensions
  
  5602   Mon Oct 3 16:18:05 2011 JenneUpdateAdaptive FilteringMeditations on the OAF


   
        
            
  
  5603   Mon Oct 3 17:06:27 2011 JenneHowToComputer Scripts / ProgramsKissel Button Generator


   
        
            
  
  5604   Mon Oct 3 17:27:23 2011 JenneUpdateSUSFailing to set SUS summary screen values

    

       
            
  
  5605   Mon Oct 3 17:57:12 2011 kiwamuUpdateASCIPPOS fixedThe
input matrix of IPPOS were fixed so that
the horizaontal motion correctly shows up
  
  5606   Mon Oct 3 20:02:59 2011 SureshUpdatePSLAM / PM ratio[Koji, Suresh]
In the previous measurement, the
PDA 255 had most probably saturated at DC,
  
  5607   Mon Oct 3 20:47:51 2011 kiwamuUpdateCDSc1lsc and c1sus didn't run[Mirko / Jenne / Kiwamu]
Just a quick update. All the realtime
processes on the c1lsc and c1sus
  
  5608   Mon Oct 3 21:20:30 2011 JenneUpdateCDSc1lsc and c1sus didn't run[Jenne, Mirko, Kiwamu, Koji, and Jamie
by phone]
We just got off the phone with Jamie. 
  
  5609   Mon Oct 3 23:52:49 2011 kiwamuUpdateCDSsome more tests for the Dolphin [Koji / Kiwamu]
 We
did several tests to figure out what could
  
  5610   Tue Oct 4 07:51:36 2011 steveUpdateCDSc1lsc and c1sus are still down 
 c1lsc and c1sus are still down.
Only ETMX and ETMY are damped
  
  5611   Tue Oct 4 10:35:08 2011 MirkoUpdateCDSc1lsc and c1sus running again[Alex, Mirko]
Alex fixed the computers this morning.
It was in fact a dolphin problem:
  
  5612   Tue Oct 4 14:41:47 2011 JenneUpdateIOOMC Trans channels are digital 0I relocked the PMC (why is it unlocking
so much lately??), and then noticed that
even though the MC is locked, MC Trans Sum,
  
  5613   Tue Oct 4 15:43:10 2011 KojiUpdateIOOclosed the shutter before the MCThe shutter before the MC was closed at
3:30 as I started working on the RFAM.
MC REFL (INLOCK): 0.6~0.7
  
  5614   Tue Oct 4 15:57:30 2011 SureshUpdateIOOMC Trans channels are digital 0
I thought this problem might be arising
because the MC2_TRANS QPD signals are not
being passed from the c1mcs to c1ioo models
  
  5615   Tue Oct 4 16:10:45 2011 SureshUpdateComputer Scripts / ProgramsMC was not dampingThe MC was not damping earlier this morning
around 11:45AM.  The reason was that
the INMATRIX on all the three MC1, 2 and
  
  5616   Tue Oct 4 16:58:45 2011 SureshUpdatePSLAM / PM ratioCorrection:        Koji noted that Mirko
actually reports a PM modulation index of
0.17 for the 11 MHz sideband (
  
  5617   Tue Oct 4 19:06:46 2011 KojiUpdateIOOclosed the shutter before the MCFinished the work at 6:30
MC REFL (INLOCK): 0.50-0.52
MC REFL (UNLOCK): 6.9
  
  5618   Tue Oct 4 19:31:17 2011 kiwamuUpdateSUSPRM and BS oplev laser diedThe
He-Ne laser which has been used for the PRM
and BS oplevs were found to be dead. 
 oplevs.png 
  5619   Tue Oct 4 20:34:20 2011 KatrinUpdateGreen Locking7kHz Peak in servo input YARM[Kiwamu, Katrin]
As reported earlier an oscillation
around 7kHz is an the PDH error signal. The
 servoinput.pngservoinput2.png 
  5620   Wed Oct 5 11:33:25 2011 steveUpdateSUSPRM and BS oplev laser replaced 
JDSU 1103P died after 4 years of
service. It was replaced with new identical
  
  5621   Wed Oct 5 14:18:09 2011 kiwamuUpdateCDSsome DAQ channel lost in c1sus : fb, c1sus and c1pem restartedI
found again the ini files had been refreshed.
I ran the activateDQ.py script (
  
  5622   Wed Oct 5 17:08:49 2011 steveUpdateSUSBS oplev spectraKiwamu and Steve,
The He/Ne oplev shows no coherece
so relative intensity noise is not limiting
 BSoplservON2.png 
  5623   Wed Oct 5 18:31:02 2011 KatrinUpdateGreen LockingExchanged mirror on YARM tableOn the Green YARM end table the second
mirror behind the laser has been exchanged.
Reason: The light is impinging on
  
  5624   Thu Oct 6 05:18:20 2011 kiwamuUpdateLSCNoise in AS55 was from clipping : fixed It turned
out the noise in AS55 was due to a clipping. 
 outofloop.png 
  5625   Thu Oct 6 15:37:26 2011 JenneUpdateGreen LockingY-green Mech Shutter Button[Katrin, Jenne]
We were poking around and tried to
make a button for the Y-green shutter, just
  
  5626   Thu Oct 6 15:40:57 2011 JenneUpdateLSCArm absl length data taken[Katrin, Jenne]
We took the data for the new absolute
length measurement of both arms, after the
  
  5627   Fri Oct 7 04:42:24 2011 kiwamuUpdateLSCDRMI locked and some plansDRMI has been
locked using the same RFPD selection as the
  
  5628   Fri Oct 7 11:45:24 2011 KojiSummaryLSCPOY11 installed, 55MHz PD at POY removedPOY11
PD was installed last night. The lock of
the Y arm was confirmed with the POY11I signal.
  
  5629   Fri Oct 7 11:53:47 2011 KojiUpdateLSCDRMI locked and some plans- REFL165 PD to be fixed (shows constant
high voltage at the DC out)
- Make POP22/110 PD
  
  5630   Fri Oct 7 14:04:48 2011 steveUpdateSUSHe/Ne intensity noise effect on oplevsThe SRM bounce peak 18.33 Hz. Suresh helped
me to retune filter through Foton, but we
failed to remove it.
 7x 
  5631   Fri Oct 7 17:35:26 2011 KatrinUpdateGreen LockingPower on green YARM tableAfter all realignment is finished, here
are the powers at several positions:
 
 DSC_3496_power.JPG 
  5632   Fri Oct 7 19:06:46 2011 SureshUpdateIOOMC spot positions: checked and corrected.Koji and Kiwamu had adjusted the MC beam
axis slightly such that we can couple the
MC output into the Y-arm without exceeding
  
  5633   Fri Oct 7 22:31:53 2011 kiwamuUpdateSUSnoisy ULSEN on ETMYYesterday
Koji was claiming that the rms monitor of
ULSEN on ETMY didn't well go down.
 ETMY_OSEMs.png 
  5634   Fri Oct 7 22:41:05 2011 KojiConfigurationGeneralScript backup fixed Script backup regularly runs on
op340m by crontab,
  
  5635   Fri Oct 7 22:48:26 2011 SureshUpdateIOOMC2 Trans QPD spot size and incident power decreasedAfter centering the spot on the MC2, I
started to adjust the spot position on MC_TRANS_QPD
to center the beam on it.  I noticed
  
  5636   Fri Oct 7 23:23:05 2011 kiwamuUpdateSUSSRM oplev was oscillatingThe SRM oplevs were found to be oscillating
because of a small phase margin.
I reduced the gains to the half of
  
  5637   Sat Oct 8 00:44:42 2011 kiwamuUpdateLSCcalibration of SRM actuatorThe AC response
of the SRM actuator has been calibrated.
 actuators.png 
  5638   Sat Oct 8 04:41:07 2011 kiwamuUpdateLSClength fluctuations in SRCLFor a comparison,
the length fluctuation of Signal-Recycled
 length_noise.png 
ELOG V3.1.3-