  11117   Sun Mar 8 00:05:37 2015 KojiConfigurationLSCCARM and DARM on RF signals!!!!!!!!!!!!!!!!!!!!Exciting! How long was it?   
  11129   Tue Mar 10 19:59:13 2015 KojiFrogsCamerasMessage from the IFO   IMG_1825.JPG 
  11134   Wed Mar 11 19:15:03 2015 KojiSummaryLSCROUGH calibration of the darm spectrum during the full PRFPMI lockI made very rough calibration of
the DARM spectra before and after the transition
for the second lock on Mar 8.
 150308_DARM_ROUGH_CALIB.pdf 
  11135   Wed Mar 11 19:48:25 2015 KojiUpdateGeneralFOL troubleshootingThere is a frequency counter code written
by the summer student.
The code needed some cleaning up.
  
  11137   Thu Mar 12 11:57:38 2015 KojiUpdateGeneralFOL troubleshootingBTW, during this trouble shoot, we looked
at the IR beatnote spectrum between the Xend
and the PSL.
  
  11151   Fri Mar 20 13:29:33 2015 KojiUpdateIOOWaking up the IFOIf the optics moved such amount, could
you check the PD alignment once the optics
are aligned?
  
  11171   Wed Mar 25 18:27:34 2015 KojiSummaryGeneralSome maintainance- I found that the cable for the AS55 LO
signal had the shielding 90% broken. It was
fixed.
  
  11173   Wed Mar 25 18:48:11 2015 KojiSummaryLSC55MHz demodulators inspection[Koji Den EricG]

We inspected the {REFL, AS, POP}55
demodulators.
  
  11174   Wed Mar 25 21:44:20 2015 KojiUpdateLSCIFO recovery / PRFPMI locking activity[Koji, Den]

- Aligned the arms with
ASS. It had alot of offset accumulated. We
  
  11179   Fri Mar 27 14:47:57 2015 KojiUpdateLSCals->pdh transition, prcl on 1f, alignmentJenne and I interviewd Den this afternoon
to make the things clear

- His "duty cycle" is
 CARM_transition.pdf 
  11180   Fri Mar 27 20:32:17 2015 KojiSummaryLSCLocking activity- Adjutsed the IMC WFS operating point.
The IMC refl is 0.42-0.43.

- The arms are aligned with ASS
  
  11183   Tue Mar 31 03:02:44 2015 KojiUpdateLSCSome locksAssuming the carrier mode in PRC is stable
and the SB is the one moving, can we just
use the POP DC QPD to control PRM?
  
  11245   Fri Apr 24 21:31:20 2015 KojiSummaryCDSautomatic mxstream resettingWe were too much annoyed by frequent stall
of mxstream. We'll update the RCG when
time comes (not too much future).
  
  11248   Sat Apr 25 03:32:45 2015 KojiUpdateASCBroken Xass?I spent a day to fix the XARM ASS, but
no real result. If the input of the 6th DOF
servo is turned off, the other error signals
  
  11312   Tue May 19 17:03:34 2015 KojiUpdateCDSMXstream restart script working (beta)AutoMX is resetting mx_stream every 5 minutes.
Basically everytime AutoMX is called,
it resets mx_stream. Is the mx_stream
  
  11323   Sun May 24 14:45:02 2015 KojiHowToGeneralHow to launch StripTools at specified locationsLLO Operator Tips:

koji.arai@cr9:/opt/rtcds/userapps/trunk/asc/l1/scripts/initial_alignment$
cat autostart_strips.sh 
  
  11332   Thu May 28 17:00:04 2015 KojiUpdateIOOFSS SLOW not engaged: is this intentional?I found that FSS SLOW servo is not engaged.
Is this intentional test to keep the NPRO
temp constant?
  
  11334   Thu May 28 21:10:46 2015 KojiUpdateGreen LockingALS-X noise huntingI have been looking at the X-end ALS setup.
I was playing with the control bandwidth
to see the effect to the phase tracker output
 150528_ALS.pdf 
  11337   Fri May 29 12:49:53 2015 KojiUpdateComputer Scripts / ProgramsChiara Backup HiccupIn fact, the file access is supposed to
be WAY faster now than in the RAID case.

As
  
  11338   Fri May 29 15:12:39 2015 KojiUpdateComputer Scripts / ProgramsChiara Backup HiccupActual data  backup_hours.pdf 
  11353   Thu Jun 11 19:40:59 2015 KojiUpdateVACVacuum comp. rebootedThe serial connections to the vacuum gauges
were recovered by rebooting c1vac1 and c1vac2.

Steve claimed that the vacuum screen
  
  11386   Wed Jul 1 09:33:31 2015 KojiUpdateGeneralShutters closed, watch dogs disabled for the RCG upgradeI closed the PSL/GREEN shutters and shut
off the LSC feedback/SUS watch dogs at 9AM
PDT, to allow Jamie to start his disruptive
  
  11394   Tue Jul 7 23:26:19 2015 KojiUpdateCDSAttempt to list CDS issuesAs Jamie succeded to realize somewhat workable
condition of the 40m CDS, I tried to list
the obvious CDS issues so that we can attack
 burt.log.zip 
  11399   Thu Jul 9 16:39:03 2015 KojiConfigurationGeneralHow to set up your own summary page environment on the LDG clusterHere is the summary of my investigation
how to set up my own "summary page"
environment on the LDG (LIGO Data Grid) cluster.
  
  11461   Wed Jul 29 21:40:39 2015 KojiSummaryCDSStatus of the frame data syncingThe trend data hasn't been
synced with LDAS since Jul 27 5AM local.

40m:
  
  11465   Thu Jul 30 11:47:54 2015 KojiSummaryCDSStatus of the frame data syncingToday it was synced at 5AM but
that was all.

40m:
  
  11466   Thu Jul 30 13:34:52 2015 KojiUpdatePEMY sesimostation is back onPlease check the spectra. If something
is wrong, please swap the cables between
X and Y in order to see if the cable is still
  
  11475   Sat Aug 1 20:46:29 2015 KojiUpdatePEMX seismo station short cable removedOMG   
  11506   Fri Aug 14 12:10:08 2015 KojiUpdatePEMGur interface box is wonkyLet's dismantle the I/F unit from the
rack and connect the cable with the lid open.
We need to trace the signal.
  
  11509   Fri Aug 14 23:49:34 2015 KojiSummaryGeneralB&K Shaker fixedI fixed a shaker that was claimed to be
broken. I had to cut the rubber membrane
to open the head.
 IMG_1947.JPG 
  11512   Mon Aug 17 17:48:12 2015 KojiUpdatePEMWasps obliterated maybe...We found the same wasp in the 40m. Megan
found it walking behind Steve desk!
  
  11520   Thu Aug 20 11:31:55 2015 KojiUpdatePEMGur interface box As reported previously, the transfer functions
of the channels look fine. (i.e. All channels
almost identical.)
 IMG_1958.JPG 
  11524   Sat Aug 22 15:48:32 2015 KojiSummaryLSCArm locking recoveryAs per Ignacio's request, I restored
the arm locking.

- MC WFS relief
  
  11551   Tue Sep 1 02:44:44 2015 KojiSummaryCDSc1oaf, c1mcs modified for the IMC angular FF[Koji, Ignacio]

In order to allow us to work on
the IMC angular FF, we made the signal paths
 c1oaf_screenshot1.pngc1oaf_screenshot2.pngc1mcs_screenshot.pngOAF_MEDM1.pngOAF_MEDM2.png 
  11604   Wed Sep 16 03:37:06 2015 KojiSummaryGreen LockingWorkable delay line setup prepared[Koji Gautam]

The variable delay line has been
setup for practical use. The hardware and
 6x 
  11605   Wed Sep 16 03:44:18 2015 KojiUpdateLSCRF micky mouse1. POP110 RF amps are powered from the
cross connect. But that +15V block has GND
connections that are not connected to the
 IMG_20150915_231038191.jpgIMG_20150915_234257144.jpg 
  11614   Thu Sep 17 19:42:43 2015 KojiUpdateLSCRF micky mouse - dodgy DIN connector blocks fixed1.
The delay-line box is now hooked up to the
cross connect +15V supply.
 IMG_20150917_190635033.jpgIMG_20150917_192551919.jpg 
  11672   Thu Oct 8 13:13:20 2015 KojiUpdateLSCDRFPMI ProgressPlease clarify: I wonder if you were at
the zero offset for CARM and DARM or not.
I am 25% excited right now.
  
  11674   Thu Oct 8 16:48:23 2015 KojiUpdateLSCDRFPMI ProgressAwesome   
  11680   Fri Oct 9 14:50:18 2015 KojiUpdateLSCALS plant shapeALS is the comparison of the
PSL laser freq vs the
end laser freq that is locked to the arm
  
  11689   Wed Oct 14 16:53:22 2015 KojiUpdateGeneralNon inverting buffer for SR560Eric needed a buffer to drive low input
impedance (~130Ohm) of his pomona box, I
quickly made a non-iverting buffer with G=+10.
 IMG_20151014_145608547.jpgIMG_20151014_145548751.jpg 
  11693   Thu Oct 15 10:59:12 2015 KojiUpdateLSCDRFPMI Locked for 20 secGreat
job!
Many thanks Eric, Gautam, and all
  
  11710   Fri Oct 23 19:27:19 2015 KojiUpdateCDSFrequency counting - workable setup preparedIt is a nice scan. I'm still thinking
about the equivalence of the moving average
and the FIR low pass that I have mentioned
  
  11720   Wed Oct 28 14:07:44 2015 KojiUpdateIOOMC WFS Offsets updateMC WFS offsets were updated to have a better
operating point.
 
  
  11725   Mon Nov 2 17:39:01 2015 KojiFrogsGeneralDRFPMI celebrationやったー!Yatta!  yatta.jpg 
  11747   Tue Nov 10 11:40:03 2015 KojiUpdateLSCUpdated interpretation of peaksWhat is the uncertainty of your RoC estimation?

One measurement of the ETMY ROC
was 57.6m, but we trust another measured
  
  11748   Tue Nov 10 11:41:56 2015 KojiUpdateLSCUpdated interpretation of peaksFYI: I've also reported the similar
mod depths of

11M: 0.194
  
  11753   Wed Nov 11 22:11:15 2015 KojiUpdateSUSPSL/IOO maintenance, TM SUS check upPMC

- Before any of the following work,
I went to the PSL table and aligned the PMC.
 TM_SUS.pdfTM_SUS_SD.pdf 
  11754   Wed Nov 11 22:50:39 2015 KojiConfigurationCDSSlow machine time&dateI was gazing at the log file for Autolocker
script (/opt/rtcds/caltech/c1/scripts/MC/logs/AutoLocker.log
)
  
  11763   Fri Nov 13 22:32:54 2015 KojiSummaryPSLPMC LO degraded, usual ERA-5 replacement, LO recovered[Yutaro, Koji]

We found that the PMC LO level
was fluctuating in a strage way (it was not
 PMC_LO.pngIMG_2093.JPGIMG_2091.JPGIMG_2095.JPGIMG_2096.JPG 