  5437   Fri Sep 16 17:09:07 2011 PaulUpdateSUSITMX oplev plan I just drew a basic picture of how
the ITMX oplev path could be reworked to
minimise the number of optics in the path.
 ITMX_oplev_plan.png 
  5438   Fri Sep 16 17:16:15 2011 JenneUpdateSUSInput matrix diagonalization: Fail![Jenne, Anamaria]
I put the new matricies in from the
free swinging test for the: ITMX, ITMY, ETMX,
  
  5439   Fri Sep 16 17:46:13 2011 kiwamuUpdateSUSSome screens fixedThe
bad medm screens have been fixed. There are
no blank fields and all the links are correct.
  
  5440   Fri Sep 16 21:26:12 2011 KeikoUpdateLSC3f demodulation board checkThe demodulation
phases and gains for the all existing channels, 
  
  5441   Fri Sep 16 21:36:25 2011 KeikoUpdateLSCPOY11 and POY55 were added New
channels, POP55 and POY11 are connected to
the rack and now available on the data system.
  
  5442   Fri Sep 16 22:11:21 2011 PaulUpdateSUSITMY transfer functionFirst of all I moved the lenses on the
ITMY/SRM oplev path to get a smaller spot
size on the QPDs. I couldn't get the beam
 ITMY_osem_to_oplev_TF.pdf 
  5443   Fri Sep 16 22:51:52 2011 PaulUpdateSUSCalibration plan for the oplevs In order to estimate the amount of
noise that the oplevs are injecting into
the GW channel, we first need to calibrate
  
  5444   Fri Sep 16 23:22:36 2011 kiwamuUpdateSUSETMX input matrix : bad YAW-SIDE couplingWith the
new input matrix, it looks like YAW and SIDE
  
  5445   Sat Sep 17 01:53:41 2011 KeikoUpdateLSCPOY and POP beams clipped Keiko, Paul, Kiwamu
We found
  
  5446   Sat Sep 17 02:07:10 2011 kiwamuUpdateSUSETMX input matrix : bad YAW-SIDE couplingExcited all the optics. They will be automatically
back after 5 hours.
Sat Sep 17 02:02:07 PDT 2011
  
  5447   Sat Sep 17 14:04:45 2011 KojiUpdateIOOPZT1 driver in placeThe PZT driver is now in place. The actual PZTs are
not connected yet!
 P9171579.JPGP9171580.JPG 
  5448   Sun Sep 18 14:08:52 2011 ranaUpdateSUSCalibration plan for the oplevsWe don't need a high quality calibration
for the optical levers. ~50% accuracy is
fine.
  
  5449   Sun Sep 18 15:34:09 2011 KojiUpdateAdaptive FilteringModifications to LSC, RFM models, added OAF model[Koji Kiwamu]
This
modification of the LSC model made the rows
  
  5450   Sun Sep 18 15:57:00 2011 KojiUpdateIOOThe PZT driver engaged to PZT1[Koji Kiwamu]
The
pzt driver for PZT1 has been installed.
  
  5451   Sun Sep 18 16:42:00 2011 KojiBureaucracyEnvironmentClean up your messMess in the lab is increasing. Kiwamu and
I had to clean up some stuffs to continue
our work. 
  
  5452   Mon Sep 19 01:07:32 2011 kiwamuUpdateSUSf2a filters on ITMs and ETMXThe f2a filters
were installed on ITMs and ETMX.
 f2a_ITMX.pngf2aITMY.pngf2a_ETMX.png 
  5453   Mon Sep 19 01:38:00 2011 kiwamuUpdateLSCtoday's locking activity[Anamaria / Kiwamu]
 The incident
  
  5454   Mon Sep 19 02:08:24 2011 kiwamuUpdateLSCfixed POP clippingActually the clipping of POP wasn't in the
chamber but
  
  5455   Mon Sep 19 02:33:34 2011 kiwamuHowToGeneralPlan for this weekGOAL1: 
Stable lock of DRMI
  
  5456   Mon Sep 19 11:49:32 2011 JenneHowToGeneralPlan for this week: SUS inversion


   
        
            
  
  5457   Mon Sep 19 12:23:30 2011 PaulUpdateSUSITMY and SRM oplev beam size reduced + next stepsI replaced the lenses that were there with
a -150mm lens followed by a +250mm lens.
This gave a significantly reduced beam size
  
  5458   Mon Sep 19 13:13:10 2011 PaulUpdateSUSITMY oplev available for use: SRM not for the moment I've got the bench set up for the
measurement of the beam spot change with
DC SRM alignment offsets. The ITMY oplev
  
  5459   Mon Sep 19 14:57:36 2011 kiwamuSummaryIOOIP POS is backIPPOS is
back. A cable had been disconnected at the
 wiring.png 
  5460   Mon Sep 19 15:30:22 2011 PaulUpdateSUSSRM oplev OSEM yaw calibration curve I made the first measurements towards
oplev calibration measurements: calibrating
the oplevs in SRM YAW. The measurements seemed
 SRM_YAW_calib_curve.png 
  5461   Mon Sep 19 15:41:48 2011 JenneUpdateSUSSUS diag stuff... just so I remember what I'm doingThe following optics were kicked:
ETMX
Mon Sep 19 15:39:44 PDT 2011
  
  5462   Mon Sep 19 15:44:32 2011 MirkoUpdateLSCRF modulation depth measurementEarlier measurements of the modulation
index were less than optimal because we had
too low transmission through the cavity.
 P9190138.JPG 
  5463   Mon Sep 19 16:20:35 2011 kiwamuUpdateLSCAS55 whitening gain decreasedThe
gain of whitening filters on AS55 was decreased
from 21 dB to 0 dB for the Y arm locking.
  
  5464   Mon Sep 19 16:44:16 2011 KeikoHowToLSCProcedure for the demodulation board check Here
I note the procedure for the demodulation
board orthogonality check for the future
  
  5465   Mon Sep 19 16:56:29 2011 PaulUpdateSUSSRM oplev pitch calibration Same measurements for SRM pitch (as
previously done for yaw in entry 5460) are
complete. The QPD is back in the path and
  
  5466   Mon Sep 19 17:45:39 2011 ranaUpdateSUSSome screens fixed


   
        
            
 Untitled.png 
  5467   Mon Sep 19 18:05:27 2011 ranaUpdateSUSSummary screen


   
        
            
 sussum.png 
  5468   Mon Sep 19 20:56:36 2011 PaulSummarySUSRemaining SRM and ITMY OSEMs calibrations 
I've now taken data for the pitch
and yaw calibrations for the OSEMs of SRM
 SRM_PITCH_calib_curve.pngSRM_YAW_calib_curve.pngITMY_PITCH_calib_curve.pngITMY_YAW_calib_curve.png 
  5470   Mon Sep 19 21:19:25 2011 KatrinUpdateGreen LockingBroadband photodiode characterizationAnother Hamasutu S3399 photodiode was tested
with the electronic circuit as described
in LIGO-D-1002969-v.
 current_noise_S3399.pdfidet_S3399.pdfS3399_response.pdfcurrent_noise_S3399_v2.pdfidet_S3399_v2.pdf 
  5471   Mon Sep 19 22:47:44 2011 JenneUpdateSUSSUS diag stuff... just so I remember what I'm doing The last person out tonight should
run the following scripts:
In Matlab: 
  
  5472   Mon Sep 19 23:19:40 2011 KeikoUpdateIOOAM modulation mistery Keiko, Anamaria
We started to investigate the AM
modulation mistery again. Checking just after
  
  5473   Tue Sep 20 02:21:10 2011 KojiUpdateLSCLSC MEDM screen cleaning upI have made some cleaning up of the LSC-related
MEDM screens.
- LSC overview screen: ADC OVFL and
  
  5474   Tue Sep 20 03:02:23 2011 KeikoUpdateLSClocking activity tonight Keiko,
Anamaria, Koji
We
  
  5475   Tue Sep 20 03:12:14 2011 AnamariaUpdateSUSJenne's Scripts startedI followed Jenne's instructions, ran the
matrix filler script and then set the optics
to freeswing. Someone has to burt resture
  
  5476   Tue Sep 20 04:12:26 2011 JenneUpdateSUSJenne's Scripts started

    

       
            
  
  5477   Tue Sep 20 09:44:44 2011 JenneUpdateSUSJenne's Scripts started

    

       
            
  
  5478   Tue Sep 20 13:57:44 2011 kiwamuUpdateIOOincident beam to MC alignedSince the MC wasn't able to capture the
00 mode in this morning I aligned the incident
beam going to MC.
  
  5479   Tue Sep 20 14:53:13 2011 JenneUpdateSUSJenne's Scripts started


   
        
            
  
  5480   Tue Sep 20 15:23:16 2011 JenneUpdateSUSfree swinging test in vacuum conditionThis is using data for the SRM from:  20
Sept 2011 03:20:00 PDT = 1000549215
You can see that there are still
 SRM.png 
  5481   Tue Sep 20 15:39:57 2011 KojiUpdateSUSfree swinging test in vacuum conditionCan't we use Yuta's auto-Q adjust script?
 http://nodus.ligo.caltech.edu:8080/40m/3723
Edit by KI :
  
  5482   Tue Sep 20 15:54:42 2011 kiwamuUpdateCamerasMC refl camera is available[Suresh / Kiwamu]
 The
MC REFL camera is now available. The camera
  
  5483   Tue Sep 20 16:31:24 2011 KeikoUpdateIOOSmall modulation depth Modulation
resonator box is removed and the modulation
  
  5484   Tue Sep 20 16:38:25 2011 KeikoUpdateIOOSmall modulation depthResonator
box and the modulations are back now. But
the modulation depth seems to be a bit smaller
  
  5485   Tue Sep 20 16:45:09 2011 JenneUpdateSUSSUS diag stuff... just so I remember what I'm doingHas the Q been checked?  Still
in progress...
  
  5486   Tue Sep 20 17:45:30 2011 kiwamuUpdateCDSdaqd is restarting by hisself ?[Jenne / Kiwamu]
 Fb
was sick. Dataviewer and Fourier Tools didn't
  
  5487   Tue Sep 20 18:03:45 2011 PaulUpdateSUSITMY and SRM oplev calibrations - measured and estimatedThe measured calibration factors for the
oplevs are as follows:
 
SRM pitch: 666urad
  