40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 109 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  10232   Thu Jul 17 17:39:57 2014 KojiUpdateElectronicsPDFR debugging attempt : REFL11What is the coupling factor between the
RF in and the RF mon of the demodulator?
  
  10234   Thu Jul 17 22:08:14 2014 KojiUpdateGeneral1X2 Rack ChangesIt sounds like the work was done carefully.
Even so, Jenne or Manasa have to run the
ALS (X and Y) to check if they are still
  
  10242   Sat Jul 19 20:51:51 2014 KojiUpdateLSCRIN in arm transmissionYour
calibration of the ALS signal should be revised.
The phase for the ALS is not an optical
  
  10262   Wed Jul 23 11:32:04 2014 KojiUpdateLSCIFO warming upAlone with the IFO. Started from some conversation
with it.
Some ALS trials: Found the Y-end
 140722_ALS.pdf 
  10285   Tue Jul 29 16:41:54 2014 KojiUpdateLSCMC servoThe MC openloop gains were measured
with several conditions
- MC fast/PC crossover was measured
 MCservo.pdf 
  10291   Tue Jul 29 20:14:10 2014 KojiUpdate40m Xend Table upgradeXarm Green steering mirror upgradeThat
was super fast! Great job, Andres and Nic!
  
  10293   Wed Jul 30 00:42:27 2014 KojiUpdateLSCMC servoI used an oscillator and an oscilloscope
to measure the open loop transfer function
at higher frequency than 100kHz.
 MCservo.pdf 
  10300   Wed Jul 30 22:01:24 2014 KojiUpdateLSCMC servoIn fact there is a pomona box between the
HV amp and the laser.
It is expected that the combination
  
  10301   Wed Jul 30 23:12:05 2014 KojiUpdateGeneralIFO patrol- The cable for the beat note was disconnected
from the frequency counter and reconnected
to the spectrum analyzer.
  
  10302   Thu Jul 31 01:08:54 2014 KojiUpdateLSCALS stability check- ALS X/Y arm stability was checked by
IR locked arms.
- Basically the stability looks same
 postXGreenUpgradeCheckup.pdf 
  10306   Thu Jul 31 12:23:38 2014 KojiSummaryElectronicsPZT Calibration1) Don't be brainless. Redo the fitting
of the Y arm. Obviously the fit is not good.
2) How can you explain the value
  
  10310   Thu Jul 31 19:37:59 2014 KojiUpdateIOOSuccessful modification of the FSSQuick note:
Migration
of the 10Hz pole from the output stage of
  
  10311   Thu Jul 31 21:21:49 2014 KojiFrogselogMicroSoft BingBot is attacking usOh,
this is cool! Thanks!
I could not figure out how to place
  
  10312   Thu Jul 31 21:59:25 2014 KojiBureaucracyGeneralAntsDon't leave your
food on tables and desks!
Also I put the souvenir chocolates
 P7316690.JPG 
  10313   Thu Jul 31 23:19:22 2014 KojiUpdateComputer Scripts / ProgramsSVN bulletinDid this break "netgpibdata"?
I couldn't download data from SR785.
Downloading from AG4395A was OK.
  
  10314   Thu Jul 31 23:43:00 2014 KojiUpdateIOOModulation frequency adjustmentThe main IFO modulation frequency was adjusted
to match with the FSR of the IMC.
The new frequency is 11.066128 MHz.
  
  10315   Fri Aug 1 00:51:07 2014 KojiUpdatePSLFSSSlowServo updateFSS Slow set point to be zero

op340m:FSS>cat FSSSlowServo
#!/usr/bin/perl -w
  
  10316   Fri Aug 1 01:29:55 2014 KojiUpdateIOOPMC issue- PMC suddenly refused to lock.
- Investigated what's wrong
- Finally, I touched RF Output Adjust
  
  10317   Fri Aug 1 01:57:24 2014 KojiSummaryIOOMC auto lockerTo make MC auto locker running correctly,
mcdown and mcup were revised
I tried it by unlocking MC several
  
  10318   Fri Aug 1 03:49:26 2014 KojiSummaryGeneralKoji - to do- Put the circuit diagram of the
sum amp on/in the circuit enclosure and associate
it with an elog [done].
  
  10319   Fri Aug 1 08:55:34 2014 KojiSummaryIOOMC auto lockerIt seems that the MC auto locker and the
FSSSlow PID servo survived a night.
PC Drive is still angry occasionally.
 MC.png 
  10320   Fri Aug 1 10:40:48 2014 KojiSummaryIOOMC servo summing ampThe
summing amp is prepared to allow up to use
bipolar full range of the FSS box output
 Fast_PZT_IF.PDF 
  10321   Fri Aug 1 11:11:12 2014 KojiUpdateIOOCurrent IMC servo configurationThe comparison between the new and old
MC servo (FSS part) was attached.
- The new servo has the same DC
 diagram.pdf 
  10322   Fri Aug 1 12:49:06 2014 KojiSummaryIOOMC servo analysisReasoning to choose the current parameters:
FSS Common: 18dB
FSS Fast: 20dB
 MC_OLTF.pdfMC_Error_Common.pdfMC_Crossover.pdfMC_CLTF_Fast.pdf 
  10325   Fri Aug 1 22:56:27 2014 KojiUpdateGeneralBeam lost in the chamber???I was investigating several issues on the
IFO. As many of you noticed and not elogged,
ITMX had frequent kicking without its oplev
  
  10327   Sun Aug 3 23:47:56 2014 KojiUpdateGeneralRecovery effortsIt's great that you guys found the beam.

Yes, ITMX kick and lost communication
  
  10338   Wed Aug 6 12:44:52 2014 KojiUpdateASCPOP QPD signalsThis is nice. Can we test this idea with
POP22 + a razor blade?
Just to take transfer functions in
  
  10341   Wed Aug 6 21:22:09 2014 KojiUpdateIOOFSS offset changedThe fast feedback
should be around zero now!
  
  10343   Thu Aug 7 11:57:59 2014 KojiSummaryIOOMC servo analysisLISO Fit for the IMC open loop TF. The
data and liso source for the fitting were
attached in the ZIP file.
 MC_OLTF_Fit.pdfIMC_OLTF.zipMC_OLTF_estimated.pdf 
  10356   Fri Aug 8 18:08:12 2014 KojiSummaryIOOMC servo analysisThe closed gain I meant is the AO path:
Use IN2 to excite the MC loop and measure
IN1 using MON2(?). 
  
  10359   Sat Aug 9 14:35:28 2014 KojiSummaryIOOMC servo analysisEric's OLTF turned out consistent with
the AO path TF that has been measured by
me on Jul 31 (entry
 MC_OLTF_Fit.pdfliso.zipMC_CLTF_Fit.pdfMC_CLTF_new.pdfMC_OLTF_new.pdf 
  10364   Mon Aug 11 22:07:31 2014 KojiSummaryIOOMC demod measurementSCLF-5!? It's surprising as the cut off
of the OLTF is just above 1Hz. cf
this entry
  
  10385   Thu Aug 14 15:42:29 2014 KojiUpdateGeneralUpdated game plan - ALS
End PDH UGF improvement / post mixer
LPF investigation (with in 2 weeks)
  
  10387   Thu Aug 14 18:02:11 2014 KojiUpdateGeneralUpdated game planGot the idea of ASC.
- Oplevs for PR2, PR3 => PR2 seems
OK. PR3 almost impossible. well
  
  10406   Mon Aug 18 09:42:50 2014 KojiSummaryIOOMCREFL PD charcterizationRiju did the
measurement of the MCREFL PD.
I found data files in her directory
 MCREFLPD_transimpedance.pdfMCREFLPD_transimpedance_zoom.pdf 
  10432   Wed Aug 27 09:12:47 2014 KojiUpdateIMCWFS tuneupI'm sure that the 1~3Hz motion comes from
the mirror motion, but not 100% sure what
is causing 
  
  10442   Tue Sep 2 22:54:27 2014 KojiSummaryLSCphase tracker UGFFYI and FMI
Phase tracker UGF is  Q_AMP
* G * 2 PI / 360 where Q_AMP is
  
  10451   Thu Sep 4 10:10:23 2014 KojiUpdateLSCRecycling cavity lengthsCom'on. This is just a 60ppm change of
the mod frequency from the nominal. How can
it change the recycling cav length by more
  
  10480   Tue Sep 9 23:05:01 2014 KojiUpdateCDSOTTAVIA lost network connectionToday the network connection of OTTAVIA
was sporadic.
Then in the evening OTTAVIA lost
  
  10492   Wed Sep 10 22:17:29 2014 KojiSummaryLSCX/Y green beat mode overlap measurement[Koji Manasa]
We made quantitative inspection of
the X/Y green beat setup on the PSL table.
  
  10500   Fri Sep 12 11:25:42 2014 KojiUpdateLSCDRMI lockingThis is great.
And I got confused. Is REFL11 going
through the CM board? 
  
  10510   Tue Sep 16 16:03:36 2014 KojiUpdatePSLLaser turned on

    

       
            
  
  10515   Wed Sep 17 18:36:03 2014 KojiHowToGeneralHow to run DTT measurement automatically
    Suppose you have a dtt template
name test.xml
    The file test.dtt
    
  
  10561   Thu Oct 2 20:54:45 2014 KojiUpdateIOOIMC WFS measurements[Eric Koji]
We made sensing matrix measurements
for the IMC WFS and the MC2 QPD.
 IMC_RIN_141002.pdfIMC_WFS_141002.pdf 
  10566   Sun Oct 5 23:43:08 2014 KojiUpdateIOOIMC WFS measurementsThere are several non scientific reasons.   
  10601   Mon Oct 13 16:57:26 2014 KojiUpdateCDSFrame builder is madCPU load seems extremely high. You need
to reboot it, I think
controls@fb /proc 0$ cat loadavg
  
  10646   Tue Oct 28 14:07:28 2014 KojiUpdateIOOIMC WFS sensing matrix measurementLast night the sensing matrix for IMC WFS&QPD
were measured.
C1:IOO-MC(1, 2, 3)_(ASCPIT, ASCYAW)_EXC
 00.png 
  10659   Fri Oct 31 19:59:26 2014 KojiUpdateGeneralSome locking work / PRMI analysisPreparations
- According to Diego's report, the
MC WFS gains were too high. We'll fix this
 PRMIsb_PRCL_OLTF.pdfPRMIsb_MICH_OLTF.pdfPRMIsb_PRCL_SPE.pdfPRMIsb_MICH_SPE.pdf 
  10660   Sat Nov 1 02:13:11 2014 KojiConfigurationLSCLSC settingsI'm leaving the iFO now. It is left with
the IR arm mode.
I pretty much messed up LSC configurations
  
  10661   Sat Nov 1 16:06:32 2014 KojiConfigurationLSCDRMI lockedContinued from ELOG
10659 

 6x 
ELOG V3.1.3-