  10313   Thu Jul 31 23:19:22 2014 KojiUpdateComputer Scripts / ProgramsSVN bulletinDid this break "netgpibdata"?
I couldn't download data from SR785.
Downloading from AG4395A was OK.
  
  10314   Thu Jul 31 23:43:00 2014 KojiUpdateIOOModulation frequency adjustmentThe main IFO modulation frequency was adjusted
to match with the FSR of the IMC.
The new frequency is 11.066128 MHz.
  
  10315   Fri Aug 1 00:51:07 2014 KojiUpdatePSLFSSSlowServo updateFSS Slow set point to be zero

op340m:FSS>cat FSSSlowServo
#!/usr/bin/perl -w
  
  10316   Fri Aug 1 01:29:55 2014 KojiUpdateIOOPMC issue- PMC suddenly refused to lock.
- Investigated what's wrong
- Finally, I touched RF Output Adjust
  
  10317   Fri Aug 1 01:57:24 2014 KojiSummaryIOOMC auto lockerTo make MC auto locker running correctly,
mcdown and mcup were revised
I tried it by unlocking MC several
  
  10318   Fri Aug 1 03:49:26 2014 KojiSummaryGeneralKoji - to do- Put the circuit diagram of the
sum amp on/in the circuit enclosure and associate
it with an elog [done].
  
  10319   Fri Aug 1 08:55:34 2014 KojiSummaryIOOMC auto lockerIt seems that the MC auto locker and the
FSSSlow PID servo survived a night.
PC Drive is still angry occasionally.
 MC.png 
  10320   Fri Aug 1 10:40:48 2014 KojiSummaryIOOMC servo summing ampThe
summing amp is prepared to allow up to use
bipolar full range of the FSS box output
 Fast_PZT_IF.PDF 
  10321   Fri Aug 1 11:11:12 2014 KojiUpdateIOOCurrent IMC servo configurationThe comparison between the new and old
MC servo (FSS part) was attached.
- The new servo has the same DC
 diagram.pdf 
  10322   Fri Aug 1 12:49:06 2014 KojiSummaryIOOMC servo analysisReasoning to choose the current parameters:
FSS Common: 18dB
FSS Fast: 20dB
 MC_OLTF.pdfMC_Error_Common.pdfMC_Crossover.pdfMC_CLTF_Fast.pdf 
  10325   Fri Aug 1 22:56:27 2014 KojiUpdateGeneralBeam lost in the chamber???I was investigating several issues on the
IFO. As many of you noticed and not elogged,
ITMX had frequent kicking without its oplev
  
  10327   Sun Aug 3 23:47:56 2014 KojiUpdateGeneralRecovery effortsIt's great that you guys found the beam.

Yes, ITMX kick and lost communication
  
  10338   Wed Aug 6 12:44:52 2014 KojiUpdateASCPOP QPD signalsThis is nice. Can we test this idea with
POP22 + a razor blade?
Just to take transfer functions in
  
  10341   Wed Aug 6 21:22:09 2014 KojiUpdateIOOFSS offset changedThe fast feedback
should be around zero now!
  
  10343   Thu Aug 7 11:57:59 2014 KojiSummaryIOOMC servo analysisLISO Fit for the IMC open loop TF. The
data and liso source for the fitting were
attached in the ZIP file.
 MC_OLTF_Fit.pdfIMC_OLTF.zipMC_OLTF_estimated.pdf 
  10356   Fri Aug 8 18:08:12 2014 KojiSummaryIOOMC servo analysisThe closed gain I meant is the AO path:
Use IN2 to excite the MC loop and measure
IN1 using MON2(?). 
  
  10359   Sat Aug 9 14:35:28 2014 KojiSummaryIOOMC servo analysisEric's OLTF turned out consistent with
the AO path TF that has been measured by
me on Jul 31 (entry
 MC_OLTF_Fit.pdfliso.zipMC_CLTF_Fit.pdfMC_CLTF_new.pdfMC_OLTF_new.pdf 
  10364   Mon Aug 11 22:07:31 2014 KojiSummaryIOOMC demod measurementSCLF-5!? It's surprising as the cut off
of the OLTF is just above 1Hz. cf
this entry
  
  10385   Thu Aug 14 15:42:29 2014 KojiUpdateGeneralUpdated game plan - ALS
End PDH UGF improvement / post mixer
LPF investigation (with in 2 weeks)
  
  10387   Thu Aug 14 18:02:11 2014 KojiUpdateGeneralUpdated game planGot the idea of ASC.
- Oplevs for PR2, PR3 => PR2 seems
OK. PR3 almost impossible. well
  
  10406   Mon Aug 18 09:42:50 2014 KojiSummaryIOOMCREFL PD charcterizationRiju did the
measurement of the MCREFL PD.
I found data files in her directory
 MCREFLPD_transimpedance.pdfMCREFLPD_transimpedance_zoom.pdf 
  10432   Wed Aug 27 09:12:47 2014 KojiUpdateIMCWFS tuneupI'm sure that the 1~3Hz motion comes from
the mirror motion, but not 100% sure what
is causing 
  
  10442   Tue Sep 2 22:54:27 2014 KojiSummaryLSCphase tracker UGFFYI and FMI
Phase tracker UGF is  Q_AMP
* G * 2 PI / 360 where Q_AMP is
  
  10451   Thu Sep 4 10:10:23 2014 KojiUpdateLSCRecycling cavity lengthsCom'on. This is just a 60ppm change of
the mod frequency from the nominal. How can
it change the recycling cav length by more
  
  10480   Tue Sep 9 23:05:01 2014 KojiUpdateCDSOTTAVIA lost network connectionToday the network connection of OTTAVIA
was sporadic.
Then in the evening OTTAVIA lost
  
  10492   Wed Sep 10 22:17:29 2014 KojiSummaryLSCX/Y green beat mode overlap measurement[Koji Manasa]
We made quantitative inspection of
the X/Y green beat setup on the PSL table.
  
  10500   Fri Sep 12 11:25:42 2014 KojiUpdateLSCDRMI lockingThis is great.
And I got confused. Is REFL11 going
through the CM board? 
  
  10510   Tue Sep 16 16:03:36 2014 KojiUpdatePSLLaser turned on

    

       
            
  
  10515   Wed Sep 17 18:36:03 2014 KojiHowToGeneralHow to run DTT measurement automatically
    Suppose you have a dtt template
name test.xml
    The file test.dtt
    
  
  10561   Thu Oct 2 20:54:45 2014 KojiUpdateIOOIMC WFS measurements[Eric Koji]
We made sensing matrix measurements
for the IMC WFS and the MC2 QPD.
 IMC_RIN_141002.pdfIMC_WFS_141002.pdf 
  10566   Sun Oct 5 23:43:08 2014 KojiUpdateIOOIMC WFS measurementsThere are several non scientific reasons.   
  10601   Mon Oct 13 16:57:26 2014 KojiUpdateCDSFrame builder is madCPU load seems extremely high. You need
to reboot it, I think
controls@fb /proc 0$ cat loadavg
  
  10646   Tue Oct 28 14:07:28 2014 KojiUpdateIOOIMC WFS sensing matrix measurementLast night the sensing matrix for IMC WFS&QPD
were measured.
C1:IOO-MC(1, 2, 3)_(ASCPIT, ASCYAW)_EXC
 00.png 
  10659   Fri Oct 31 19:59:26 2014 KojiUpdateGeneralSome locking work / PRMI analysisPreparations
- According to Diego's report, the
MC WFS gains were too high. We'll fix this
 PRMIsb_PRCL_OLTF.pdfPRMIsb_MICH_OLTF.pdfPRMIsb_PRCL_SPE.pdfPRMIsb_MICH_SPE.pdf 
  10660   Sat Nov 1 02:13:11 2014 KojiConfigurationLSCLSC settingsI'm leaving the iFO now. It is left with
the IR arm mode.
I pretty much messed up LSC configurations
  
  10661   Sat Nov 1 16:06:32 2014 KojiConfigurationLSCDRMI lockedContinued from ELOG
10659 

 6x 
  10663   Mon Nov 3 17:43:14 2014 KojiUpdateASCIMC to IFO angular motionI wonder if this is the coherence caused
by the beam itself, or caused by the same
ground motion.
  
  10664   Mon Nov 3 17:56:57 2014 KojiUpdateLSCSRM calibrationSRM
Calibration
After the DRMI measurements on Friday,
 SRY_SRM_CALIB_RAW.pdfSRY_SRM_CALIB.pdf 
  10669   Wed Nov 5 11:09:44 2014 KojiUpdateLSC3F RFPD RF spectraIf you look at the intermodulation at 14
(4+10) and 16 (6+10), 15 (5+10) would make
any problem, thanks to the notch at 1f and
  
  10675   Thu Nov 6 01:58:55 2014 KojiUpdateLSC3F RFPD RF spectraWhere is the PD out spectrum measured with
the coupler??? 
  
  10681   Thu Nov 6 12:58:28 2014 KojiUpdateIOOWFS offset was resetIMC WFS operating point seemed to get degraded.
- IMC WFS feedback was relieved.
- WFS servo was turned off.
  
  10695   Tue Nov 11 01:38:23 2014 KojiUpdateLSCNotch at 110MHzTo further reduce the RF power at 110MHz
in the REFL165 chain, I made a twin-t notch
in a pomona box.
 twin_t_notch.pdfnotch_tf.pdf 
  10698   Tue Nov 11 21:41:09 2014 KojiUpdateLSC3f DRMI sensing matSensing
matrix calculation using DTT + Matlab
Note: If the signal phase is, for
 DRMI_radar.pdf 
  10704   Wed Nov 12 20:11:41 2014 KojiUpdateIOOMC WFS gain reduced againMC WFS was oscillative at 1Hz. I've reduced
the servo gain further (x1, x1, x10, x1,
x1, and x10).
  
  10706   Wed Nov 12 22:22:11 2014 KojiSummaryIOOEstimation of the angular jitter imposed by the TTs[Koji, Rana, Jenne]
One coil of the TT produce 36nrad/rtHz
at DC.
 03.png 
  10728   Thu Nov 20 22:43:15 2014 KojiUpdateIOOIMC WFS damping gain adjustmentFrom the measured OLTF, the dynamics of
the damped suspension was inferred by calculating
H_damped = H_pend / (1+OLTF).
 MC_OLTF_CLTF.pdf 
  10748   Wed Dec 3 01:46:12 2014 KojiUpdateLSCTried cav pole compensation trick - failWhere did these 200Hz, 6kHz come from?

I wonder what are the correct
filters to be incorporated in the filter
  
  10749   Wed Dec 3 02:01:57 2014 KojiUpdateLSCIR Resonance Script StatusThe other night (before the holidays),
I tried ALS offset tuning  with IR POX/POY
signals and it worked pretty good.
  
  10813   Wed Dec 17 19:31:55 2014 KojiUpdateASCASS retunedI wonder what to do with the X arm.
The primary purpose of the
ASS is to align the arm (=transmission),
  
  10827   Mon Dec 22 13:34:34 2014 KojiUpdateelogStrange ELOG serachI tried to find my own entry and faced
with a strange behavior of the elog.
The search button invoked the following
  
ELOG V3.1.3-