  12064   Tue Apr 5 14:16:34 2016 gautamUpdateCDSBLRMS for optics suspensions - library block UPDATEDAs discussed in a Wednesday meeting some
time ago, we don't need to be writing
channels from BLRMS filter modules to frames
  
  12063   Tue Apr 5 11:42:17 2016 gaericqutamUpdateendtable upgradeTABLE REMOVALThere is currently no table at
the X end! 

We have moved the vast majority
  
  12062   Tue Apr 5 08:55:51 2016 SteveUpdateSUSlocal EQ 3.1mLocal earth quake 3.1 magnitude in Valencia,
Ca did not trip our suspensions.

 
 eq3.1Valencia.png 
  12061   Mon Apr 4 15:04:14 2016 gautamUpdateendtable upgradeCOMPONENT REMOVAL
I'm
planning to start removing components from
  
  12060   Mon Apr 4 10:59:12 2016 gautamUpdateendtable upgradeproposed layout v3I realized I had overlooked an important
constraint in the layout, which is that the
enclosure will have two supports that occupy
 ETMX_proposed_layout_v3.pdfIR_modematch.pdfGreen_modematch.pdfXendALaMode.zipETMX_proposed_layout_dimensions.dwg 
  12059   Fri Apr 1 13:11:26 2016 ericqUpdateWienerFilteringBilinear Noise TestingI've been banging my head against bilinear
noise subtraction, and figured I needed to
test things on some real hardware to see
 bilinear_drive.pdf40m_bilin.pdf 
  12058   Thu Mar 31 19:49:31 2016 gautamUpdateendtable upgradeproposed layout v2The major changes from the previous layout:


I've depicted the Green
reflected beam path more accurately - I approximately measured
 ETMX_proposed_layout_v2.pdf 
  12057   Thu Mar 31 09:38:41 2016 SteveUpdateendtable upgradeY end 4x3 existing layoutBeam colors: 1064 nm red, 514 nm green
and 633 nm yellow.

There should be room for lens in
 ETMY4x3layout.jpg 
  12056   Wed Mar 30 17:38:52 2016 gautamUpdateendtable upgradeX end table proposed layout Attachment 1: This
is a photo of the current X end table optical
layout with the beampaths of the various
 ETMX_3x2.JPGlayout_details_20160328.pdfETMX_proposed_layout.pdf 
  12055   Wed Mar 30 16:40:24 2016 ericqUpdateLSC2016 vs 2010I haven't found any data files for
the DARM spectrum of the previous generation
of 40m, but with some GIMP-fu, I have plotted
 2016_vs_2010.png 
  12054   Wed Mar 30 11:35:24 2016 steveUpdatesafetyBS visitor's viewport is protected with lexan[quote]The four horizontal viewports of arms
are protected 
by 3/8" thick, 8.5" OD Lexan disk of MR10
  
  12053   Tue Mar 29 03:16:21 2016 ericqUpdateLSCDRFPMI Locked Once More[ericq, Gautam]

Three RF-only locks longer than
a minute tonight, out of 5 total attempts. 
 2016-03-29_calibdarm.pdf2016-03-29_DRFPMI_errctrl.pdfDRFPMI_DTT.zip 
  12052   Mon Mar 28 22:16:44 2016 KojiUpdateGeneralNew WiFi routerI configured three more mini wifi extender.
They are ready to use.

We should add these to the host
  
  12051   Mon Mar 28 10:43:18 2016 SteveUpdateendtable upgradeETMX 4'x2' optical table pictures 

 
 ETMX4x2Layout.jpgETMX_4x2.JPGETMXopt_4x2.JPG 
  12050   Mon Mar 28 08:30:09 2016 SteveUpdateSUSPRM damping restoredRecent  EQ 4.8 mag San Felipe, Mexico
trips PRM sus damping.

PRM damping restored. PMC locked.
 shaking.png 
  12049   Sat Mar 26 18:28:24 2016 KojiUpdateelogelogd flakinessElogd have been restarted several times
today because it died everytime I submit
something.
  
  12048   Fri Mar 25 23:54:04 2016 ranaUpdatePEMGuralp SeismometersSomething seems not right. The Guralp response
should be flat in velocity from 0.05-30 Hz.
Why is there any feature at 1 Hz? Saturation
  
  12047   Fri Mar 25 19:17:28 2016 NikhilUpdatePEMGuralp SeismometersCalibration
of Guralp Seismometers 

Objective
 16x 
  12046   Thu Mar 24 08:20:52 2016 SteveUpdatePEMGuralp-A calibration sheetCalibration
Data

All Guralp
  
  12045   Thu Mar 24 07:56:09 2016 SteveUpdateCalibration-RepairNO Noise Eater for 1W Innolight1W Innolight is NOT getting Noise Eater
as it was decided yesterday at the 40m meeting.
Corrected 3-25-2016
  
  12044   Wed Mar 23 15:23:12 2016 SteveSummaryPEMGuralps as connectedWe have one calibration sheet of GUR- B, from 26
June 2008,    model CMG-T40-0008, 
 GUR_A.jpgGUR_B.jpgGUR_Interface_Box.jpg 
  12043   Wed Mar 23 11:55:47 2016 SteveUpdateGeneral Smart UPS 2200 Battery ReplacedBatteries replaced in control room UPS
after 3 years from replaceUPSbattery.com

 
  
  12042   Tue Mar 22 21:30:15 2016 KojiUpdateIOOPMCIMC aligned, WFS offset adjustedThe alignment of the PMC adjusted on the
PSL table: Trans 0.737->0.749

The alignment of the IMC adjusrted
 08.png 
  12041   Tue Mar 22 14:12:18 2016 SteveUpdateIOOLaser is turned back onThe 2W Innolight was turned on.

 
 off-onAgain.png 
  12040   Mon Mar 21 14:29:32 2016 SteveUpdateCalibration-Repair1W Innolight laser repair diagnoses 




  
  12039   Mon Mar 21 10:07:45 2016 SteveUpdateSUSETMX enclosure updateThe enclosure top piece in the middle is
still in the machine shop.

The carpenter who helps in the
 ETMXenclosure.jpg 
  12038   Fri Mar 18 11:04:56 2016 SteveUpdateSUSinverted pendulumKate Dooley picked up this item today.  invPeng.jpg 
  12037   Wed Mar 16 16:02:40 2016 KojiUpdateSUSwire standoff test cutIt looks almost OK, but we need a bit sharper
picture for both the groove and thw wire.
 ruby.png 
  12036   Wed Mar 16 15:36:03 2016 SteveUpdateSUSwire standoff test cutRuby wire standoff 1 mm od. with
V-groove test cut. SOS sus wire 0.0017"
od. is in the background.
 0182_-_20160316_135935.png 
  12035   Tue Mar 15 10:31:58 2016 SteveUpdateIOOLaser is turned back onIt's may be the janitor's doing.

I noticed that the HEPA filers
were off. They are turned on at 20%
 2WlaserOff-On.png 
  12033   Mon Mar 14 22:42:23 2016 gautamUpdateendtable upgradeInventory check


  
  12032   Sat Mar 12 22:23:37 2016 ranaSummaryIOOPMC relockedFound it locked on TEM01 mode.

Sweets in the fridge for non-PhD
holders, courtesy of the highest levels of
  
  12031   Fri Mar 11 16:52:53 2016 SteveUpdatePEMleaky roofJohannes found dripping water at the vac
rack. It is safe. It is not catching anything.
Actual precipitation was only 0.62"
 leakyRoof.jpgleakyRoofA.jpg 
  12030   Thu Mar 10 16:32:45 2016 ranaUpdateendtable upgradeInventory checkIts not a good idea to use green mounts
with green lasers. Steve should be able to
get another copy of the EY doubler mount
  
  12029   Thu Mar 10 16:29:32 2016 gautamUpdateendtable upgradeInventory checkI did a quick sweep of the lab to find
out what hardware has already been acquired
for the X-end table upgrade. The attached
 Inventory_check.pdfDoubler_comparison.pdf 
  12028   Thu Mar 10 03:03:11 2016 ericqUpdateLSCDRFPMI Power stable, but no RF handoff[ericq, Gautam]

We worked on getting the DRFPMI
back up and running, hoping the ALS performance
  
  12027   Tue Mar 8 18:22:20 2016 ranaUpdateGreen LockingLaser swap - some improvementWhy is the transmission of X green so low?
Perhaps you can phase lock the IR and then
scan the X frequency, using the X arm as
  
  12026   Mon Mar 7 23:51:36 2016 gautamUpdateGreen LockingLaser swap - some improvement


 PomonaTF.pdfXPDH.pdfYPDH.pdfgreenbeat_20160307.pdf 
  12025   Mon Mar 7 20:40:02 2016 ericqUpdateCDSFB down againWe went and looked at the monitor plugged
into FB. All kinds of messages were
being spammed to the screen (maybe RAM errors),
  
  12024   Sun Mar 6 15:24:05 2016 gautamUpdateCDSFB down againI came in to check the status of the nitrogen
and noticed that the striptool panels in
the control room were all blank.
 58.png 
  12023   Sat Mar 5 23:31:01 2016 gautamUpdateGreen LockingLaser swap - some updatesI've been a little behind on my elogs
so here is an update of the end laser situation.

IR beat for X-end recovered
 AUXxTelescope.png.pngPM_setup.pdfPLLolg.pdfAMPM20160303.pdfIRbeat_20160304.pdf 
  12022   Sat Mar 5 10:37:48 2016 ranaUpdateIOOPSL Laser OpenedSorry, that was me; taking some photos
of the PSL and EX mirrors.

  
  12021   Fri Mar 4 13:52:41 2016 ericqUpdateIOOPSL Laser OpenedPSL Table doors were open, and the laser
shutter was closed.

Doors have been closed, laser has
  
  12020   Fri Mar 4 11:07:10 2016 SteveUpdatesafety crane inspection completes 2016 safey auditAll 3 cranes inspected by professional
and load tested with 450 lbs at max reach.

 
 craneInsp2016.jpg 
  12019   Fri Mar 4 01:11:41 2016 gautamUpdateGreen LockingLaser swap - both green beatnotes foundThe good news: both green beatnotes have
now been found. The problem was alignment
on the green beat PD on the PSL table which
 IR_beat_20160303_green.pdf 
  12018   Thu Mar 3 10:19:20 2016 SteveUpdatesafetysafety audit 2016Bob cleaned the safety glasses. They were
sonicated in warm 2% Liquinox  water
for 10 minutes.  Steve checked them
 checkedSG.jpg 
  12017   Thu Mar 3 01:25:50 2016 gautamUpdateGreen LockingLaser swap - 2 IR + 1 green beatnotes found[ericq, gautam]

Summary of work done tonight:


The PDH setup at the Y-end
 IR_beat_20160303_2.pdf 
  12016   Wed Mar 2 17:42:19 2016 gautamUpdateGreen LockingLaser swap - some progress[Koji, Johannes, gautam]

With Koji's and Johannes'
help, I managed to resolve the coupling the
  
  12015   Wed Mar 2 10:09:28 2016 SteveUpdatesafetyprofessional crane inspectionThe crane inspection is scheduled for this
coming Friday from 8-12

 
  
  12014   Tue Mar 1 09:37:15 2016 steveUpdateVACvac rack UPS batteries replacedAmstron batteries replaced after 11 months
with SP-12-5.5HR,  2 years warranty
from replaceUPSbattery.com
 vacRackBat.jpg 