40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 103 of 169  Not logged in ELOG logo
Entry  Tue Jun 7 16:11:09 2011, steve, Update, Cameras, ITM camera lenses changed P1070865.JPGP1070860.JPG
    Reply  Wed Jun 8 22:48:09 2011, rana, Update, Cameras, ITM camera lenses changed 
Entry  Wed Jun 8 16:41:48 2011, valera, Update, ASS, X and Y arm dither alignment status BeamPositionIndicators.png
Entry  Mon Jun 6 22:41:22 2011, rana, Update, SUS, Switching problem in SUS models a.pdf
    Reply  Tue Jun 7 11:39:27 2011, Jamie, Update, SUS, No binary output module in ETMY 
Entry  Mon Jun 6 23:56:16 2011, rana, valera, Configuration, SUS, ETMX/ETMY OSEM whitening 
Entry  Mon Jun 6 18:29:01 2011, Jamie, Joe, Update, CDS, COMPLETE FRONT-END REBUILD (WITH PROBLEMS (fixed)) 
Entry  Fri Jun 3 18:12:03 2011, steve, Update, Computers, no PEM channels 
    Reply  Mon Jun 6 17:28:31 2011, steve, Update, Computers, still, no PEM channels P1070846.JPG
Entry  Mon Jun 6 17:22:09 2011, valera, Configuration, LSC, Clipping in the X arm 1064 um trans path XarmTransMon.pdf
Entry  Mon Jun 6 02:09:39 2011, rana, Update, Electronics, POY11 Rework Nearly Complete 777.png
    Reply  Mon Jun 6 16:44:34 2011, Koji, Update, Electronics, POY11 tested POY11_test.pdf
Entry  Sat Jun 4 15:26:04 2011, Larisa Thorne, Update, Electronics, Seismometer Box Update SeisBoxLISO_transfer.pdfSeisBoxLISO_noise.pdf
Entry  Sat May 21 17:02:38 2011, Koji, Update, Electronics, Alberto's 11MHz was modified to POP55MHz POP55_schematic_110520_KA.pdfPOP55_transimpedance.pdf
    Reply  Fri Jun 3 14:27:32 2011, Koji, Update, Electronics, POP55 test results POP55_test.pdf
Entry  Thu May 19 03:13:54 2011, kiwamu, Update, Electronics, REFL11 not working 1305799561ZgerKtrd.gif
    Reply  Fri May 20 11:37:44 2011, Koji, Update, Electronics, REFL11 fixed (REFL11 not working) REFL11_transimpedance.pdf
       Reply  Thu Jun 2 23:10:10 2011, Koji, Update, Electronics, REFL11 test results (Re: REFL11 fixed) REFL11_test.pdf
Entry  Thu Jun 2 16:31:41 2011, Jamie, Update, CDS, aquired SUS channel name suffixes changed from _DAQ to _DQ 
Entry  Thu Jun 2 16:23:42 2011, Jamie, Update, SUS, SUS control models updated to use new sus_single_control library part 
Entry  Thu Jun 2 10:19:37 2011, Alex Ivanov, Summary, DAQ, installed new daqd (frame builder) program on fb (target/fb/daqd) 
Entry  Fri May 6 01:27:12 2011, Koji, Summary, General, aLIGO BBPD / Green PD investigation PD_response.pdfFFD-100_AP389_MCL.pdf
    Reply  Sat May 7 12:57:54 2011, Koji, Summary, General, aLIGO BBPD / Green PD investigation PD_response.pdf
       Reply  Tue May 10 09:05:49 2011, Koji, Update, General, aLIGO BBPD / Green PD investigation PD_response.pdf
          Reply  Wed Jun 1 21:56:43 2011, Koji, Update, General, aLIGO BBPD / Green PD final result PD_response.pdflinearity_GALI_6.pdf
Entry  Thu Oct 28 19:10:26 2010, tara, Update, Electronics, TTFSS for 40m 
    Reply  Mon Apr 11 20:03:05 2011, tara, Update, Electronics, TTFSS for 40m 
       Reply  Wed Jun 1 13:33:22 2011, koji, tara, Update, Electronics, TTFSS #7  q4.png
Entry  Tue May 31 17:30:42 2011, steve, Update, SUS, ETMY damping restored 
Entry  Tue May 31 16:07:57 2011, Larisa Thorne, Configuration, Electronics, Seismometer Box Update SeisBoxLISOplot1.pdfSeisBoxLISOplot2.pdfSTS2diagram_original.pdf
Entry  Tue May 31 15:45:37 2011, Jamie, Update, CDS, c1iscey IOchassis powered off for some reason. repowered. 
Entry  Tue May 31 14:29:00 2011, jzweizig, Update, CDS, frames 
Entry  Tue May 31 11:34:13 2011, steve, Summary, SAFETY, safety glasses checked P1070823.JPG
Entry  Tue May 31 11:26:29 2011, josephb, Update, CDS, CDS Maintenance 
Entry  Mon May 30 23:14:27 2011, valera, Update, ASC, Y arm initial alignment 
Entry  Fri May 27 17:52:53 2011, steve, Update, LSC, LSC rack cables strain relieved & labeled 
Entry  Tue May 17 22:50:00 2011, Jamie, Configuration, LSC, New digital lockin added to LSC model/screen lsc-mdl-lockin.pnglsc-screen-lockin.pnglsc-lockin-screen.png
    Reply  Wed May 18 22:11:31 2011, rana, Configuration, LSC, New digital lockin added to LSC model/screen Untitled.png
       Reply  Wed May 25 20:12:55 2011, Jamie, Configuration, LSC, New digital lockin added to LSC model/screen lsc-lockin-adl.png
          Reply  Thu May 26 17:10:21 2011, Jamie, Configuration, LSC, New digital lockin added to LSC model/screen 
Entry  Wed May 25 19:19:11 2011, Jamie, Configuration, CDS, !!!CHECK IN YOUR MODELS!!! 
Entry  Wed May 25 19:03:59 2011, Jamie, Configuration, CDS, Update rtcds checkout of cds_user_apps with new top-level directory names. 
Entry  Mon May 23 14:28:23 2011, kiwamu, Configuration, LSC, POY55 installed POY55.png
    Reply  Mon May 23 18:16:42 2011, Koji, Configuration, LSC, POY55 installed 
Entry  Mon May 23 18:10:41 2011, kiwamu, Update, LSC, f2p filters on PRM : not good f2p_PRM.png
Entry  Sat May 21 06:19:46 2011, kiwamu, Update, LSC, DRMI trial : no luck 
    Reply  Mon May 23 00:36:51 2011, kiwamu, Update, LSC, DRMI trial : sucess 
       Reply  Mon May 23 12:27:26 2011, kiwamu, Update, LSC, DRMI trial : details 
Entry  Wed May 18 07:13:00 2011, Suresh, Update, RF System, Demod board measurements Demod_Board_measurements.pngDemod_Board_measurements.png
    Reply  Fri May 20 05:41:22 2011, Suresh, Update, RF System, Demod board measurements 
Entry  Fri May 20 03:29:04 2011, kiwamu, Update, CDS, Binary IO box on 1X5 : LEDs off DSC_3050_small.jpg
Entry  Fri May 20 03:01:17 2011, kiwamu, Update, LSC, locking status Screen_shot_2011-05-20_at_2.50.00.png
Entry  Fri May 20 01:02:50 2011, loose connection hunter, Update, SUS, loose connection on ETMY rack ETMY_loose.png
Entry  Thu May 19 19:41:17 2011, Suresh, Update, RF System, DAQ channel Assignments for RF PDs 1Y2_Rack_Layout.png
Entry  Thu May 19 12:09:41 2011, josephb, Update, CDS, AA filter box pulled from 1X5, optic suspensions currently off 
    Reply  Thu May 19 17:53:03 2011, steve, Update, CDS, AA filter box modified at 1X5 P1070727.JPG
Entry  Thu May 19 16:46:20 2011, kiwamu, Update, LSC, c1lsc model : input channels rearanged c1lsc.png
Entry  Thu May 19 00:15:20 2011, Jenne, Update, elog, Restarted, Italian-style 
    Reply  Thu May 19 00:22:21 2011, rana, Update, elog, Restarted, Italian-style 
Entry  Wed May 18 18:48:46 2011, kiwamu, Update, Electronics, identification of RFPD interface cables 
Entry  Wed May 18 18:33:46 2011, Aidan, Update, elog, restarted elog with script 
Entry  Fri May 13 23:04:58 2011, Suresh, Update, RF System, DC power supply on RF distribution box has been replaced. P5130120.JPG
    Reply  Sat May 14 14:12:16 2011, Koji, Update, RF System, DC power supply on RF distribution box has been replaced. sorensen.png
       Reply  Wed May 18 15:54:50 2011, Koji, Update, RF System, DC power supplies for the RF generation box in place 
          Reply  Wed May 18 17:06:39 2011, Suresh, Update, RF System, DC power supplies for the RF generation box in place 
    Reply  Sat May 14 14:50:21 2011, Koji, Update, LSC, 1Y2 5V Blown Fuse found -> Fixed 1Y2_5V_Fuse.JPG
Entry  Wed May 18 16:52:23 2011, Suresh, Update, RF System, Cables for AS11 PD are in place 1Y2_Rack_Layout_short-term.png
Entry  Thu May 12 23:50:10 2011, Suresh, Update, RF System, POY55_Demod board Hardware change completed 
    Reply  Wed May 18 07:18:15 2011, Suresh, Update, RF System, POY55_Demod board Hardware change completed 
Entry  Tue May 17 19:38:32 2011, kiwamu, Update, SUS, wrong connection on 1X5 wrong.pngcorrect.png
Entry  Tue May 17 18:09:13 2011, Jamie, Kiwamu, Configuration, CDS, c1sus and c1auxey crashed, rebooted 
Entry  Tue May 17 17:01:22 2011, jamie, Configuration, CDS, Update LSC channels from _DAQ to _DQ 
Entry  Tue May 17 16:53:22 2011, kiwamu, Update, SUS, oplev sign was wrong on ETMY 
Entry  Tue May 17 11:45:20 2011, Jamie, Configuration, CDS, purged non-c1 site files from rtcds checkout of cds_user_apps 
Entry  Tue May 17 01:05:56 2011, kiwamu, Update, LSC, Asymmetry measurement prep : recentering works 
Entry  Mon May 16 17:11:28 2011, steve, Update, Electronics, strain relieved 1X1 P1070724.JPG
ELOG V3.1.3-