40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 103 of 357  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  2136   Thu Oct 22 23:14:54 2009 ZachUpdateWIKI-40M UpdatePSL Table Diagram wiki entry

    

       
            
  
  2138   Fri Oct 23 15:02:00 2009 robUpdateloremarconi phaseSo, it appears that one doesn't even have
to change the Marconi set frequency to alter
the phase of the output signal.  It
  
  2139   Sat Oct 24 04:57:33 2009 ranaUpdateloremarconi phase


   
        
            
  
  2141   Mon Oct 26 03:57:06 2009 robUpdateLockingbadLock acquisition has gone bad tonight. 
The initial stage works fine, up
through handing off control of CARM to MCL. 
  
  2142   Mon Oct 26 15:40:01 2009 steveUpdatePSLlaser power is down The laser power is down 5-6%  laserpowerdown.jpg 
  2143   Mon Oct 26 17:45:34 2009 JenneUpdateAdaptive FilteringNew changes to the OAF fe code[Alex, Jenne, Sanjit]
Alex came to the 40m today, and did
several awesome things in OAF-land.
  
  2144   Mon Oct 26 18:15:57 2009 robUpdateIOOMC OLGI measured the mode cleaner open loop gain. 
It's around 60kHz with 29 degs of phase margin.
  
  2145   Mon Oct 26 18:49:18 2009 kiwamuUpdateLSCOMC-LSC timing issueAccording to my measurements I
conclude that LSC-signal is retarded from
 exp1.pngexp2.pngOMC_LSC60sec.png 
  2146   Mon Oct 26 19:12:50 2009 kiwamuUpdateLSCdiagnostic script for LSC timingThe diagnostic script I've written is available
in the 'caltech/users/kiwamu/work/20091026_OMC-LSC-diag/src'.
To run the script, you can just execute
  
  2147   Mon Oct 26 23:14:08 2009 KojiUpdatePSLlaser power is down I adjusted the steerings to the PMC and
gained 7%. Now the MC_TRANS 7.0 has been
recovered.
 PSL091026.png 
  2148   Tue Oct 27 01:45:02 2009 robUpdateLockingMZ[quote] Tonight we also encountered a large
peak in the frequency noise around 485 Hz.
 Changing the MZ lock point (the spot in
  
  2149   Tue Oct 27 15:55:04 2009 KojiUpdateGeneralISS injection work / HEPA is onI was working on the ISS excitation to
take TFs.
I used ISS IL excitation, stealing
  
  2151   Tue Oct 27 18:01:49 2009 robUpdatePSLhmmmA 30-day trend of the PCDRIVE from the
FSS.
 pcdrive_trend.png 
  2152   Tue Oct 27 18:19:14 2009 robUpdateLockingbad

    
        
 MCF_issue.pngno_MCF_issue.png 
  2153   Tue Oct 27 19:37:03 2009 kiwamuUpdateLSCcron job to diagnose LSC-timingI set a cron job on allegra.martian to
run the
diagnostic script every weekend.
  
  2154   Wed Oct 28 05:02:28 2009 robUpdateLockingbackLockAcq is back on track, with the full
script working well.  Measurements in
progress.
  
  2155   Wed Oct 28 09:12:18 2009 steveUpdatePSLPMC power on the rise?The PMC power is seems to be on the rise,
( MOPA_AMPMON is dropping ?) but I do not
think it is real. We have Santa Anna wind
 pmcprising.jpg 
  2156   Wed Oct 28 14:39:10 2009 steveUpdatePEMafter the tour of the 40m Illuminators and PSL lights turned off.
HEPA filter speed increased from 20 to 100%
  
  2158   Thu Oct 29 13:48:32 2009 KojiUpdatePSLNPRO LTMP lowered 9.5deg13:00 Found MC TRANS less than 7.
13:50 Go into the PSL table.
14:20 Work done. Now I am running
 091028_PSL.png 
  2159   Thu Oct 29 18:04:02 2009 JenneUpdateAdaptive FilteringMore work on saving coeffs on the OAF screen[Sanjit,Jenne]
Sanjit has been working today on
trying to get the OAF coefficients to save
  
  2160   Thu Oct 29 18:25:33 2009 SanjitUpdateAdaptive FilteringMore work on saving coeffs on the OAF screen

    
        
  
  2161   Thu Oct 29 20:21:14 2009 KojiUpdatePSLNPRO LTMP lowered 9.5degHere is the plots for the powers. MC TRANS
is still rising.
What I noticed was that C1:PSL-FSS_PCDRIVE
 PSL_MC.png 
  2162   Thu Oct 29 21:51:07 2009 robUpdateLockingbad

    
        
 itsback.png 
  2163   Fri Oct 30 04:41:37 2009 robUpdateLockingworking againI never actually figured out exactly what
was wrong in entry 2162,
but I managed to circumvent by changing the
  
  2165   Fri Oct 30 10:52:56 2009 JenneUpdatePSLHEPAsZach found the HEPA switch on the PSL table
OFF.  He turned them on.
  
  2166   Sun Nov 1 17:58:44 2009 JenneUpdateGeneralUpdate on Video SwitchThe current update on the Chameleon video
switch is: no progress.
I connected the old laptop that Rob/Steve
  
  2167   Mon Nov 2 10:56:09 2009 kiwamuUpdateLSCcron job works succesfully & no timing jitterAs
I wrote on Oct.27th, the cron job works
every Sunday.
  
  2168   Mon Nov 2 13:00:55 2009 KojiUpdateIOOPMC aligned, MC WFS alignedThe beam to PMC aligned. The beam to MC
WFS cameras aligned.
PMC Trans increased from 2.73 to 2.75
  
  2170   Mon Nov 2 15:27:08 2009 JenneUpdatePEMGur2 cables have been movedThe cables labeled "Gur2" which
were connected to channels 2,3,4 of the PEM-ADCU
have been moved to the PCIX ADC which is
  
  2171   Mon Nov 2 21:09:15 2009 SanjitUpdateAdaptive FilteringMore work on saving coeffs on the OAF screen 
I made some changes in the code (all
commented in the installed and SVN version)
  
  2172   Tue Nov 3 03:45:04 2009 rob UpdateIOOfrequency noise problem

    
        
 noise.pngspectra.pdf 
  2174   Wed Nov 4 16:49:32 2009 AlbertoUpdateLSCArm Cavity Finesse MeasurementI'm going to work on the X arm to measure
the arm cavity finesse.
The idea is to measure the cavity
 DSC_0952.JPG 
  2175   Wed Nov 4 18:35:19 2009 AlbertoUpdateLSCArm Cavity Finesse Measurement

    
        
  
  2176   Wed Nov 4 21:46:18 2009 AlbertoUpdateLSCArm Cavity Finesse Measurement

    
        
  
  2177   Wed Nov 4 23:17:51 2009 AlbertoUpdateLSCX Arm Cavity transfer FunctionI measured the transfer function between
MC_TRANS and TRX and I'm attaching the result.
 ArmCavityTF02.png 
  2178   Thu Nov 5 05:07:22 2009 ranaUpdateLSCX Arm Cavity transfer FunctionI would have guessed that you have to calibrate
the detectors relative to each other before
trying this. Its also going to be tricky
  
  2179   Thu Nov 5 12:34:26 2009 kiwamuUpdateComputerselog rebootedI found elog got crashed. I rebooted the
elog daemon just 10minutes before.
  
  2180   Thu Nov 5 16:24:40 2009 JenneUpdateGeneralDrill Press is down for the countThe on/off switch for the drill press is
broken.  Replacement parts should be
here tomorrow. 
  
  2181   Thu Nov 5 16:24:59 2009 KojiUpdateCDSETMY CDS test stuffJoe, Peter, Jay, Koji, Rana
We put the new CDS stuff at Y end
1Y9 rack.
  
  2182   Thu Nov 5 16:30:56 2009 peteUpdateComputersmoving megatron Joe and I moved megatron and its
associated IO chassis from 1Y3 to 1Y9, in
preparations for RCG tests at ETMY.
  
  2184   Thu Nov 5 19:25:11 2009 AlbertoUpdateLSCX Arm Cavity transfer Function


   
        
            
 PDA255CalibrationTF03.png 
  2185   Thu Nov 5 22:30:09 2009 AlbertoUpdateLSCX Arm Cavity Transfer FunctionIt seems that just repeating the measurement
was enough to get a good transfer function
of the x arm cavity. Here's what I got.
 XarmTF01.png 
  2186   Thu Nov 5 23:09:34 2009 AlbertoUpdateLSCY Arm Cavity Transfer FunctionAs for the X Arm, this the transfer function
I measured for the Y arm cavity.
 YarmTF01.png 
  2188   Fri Nov 6 00:24:06 2009 AlbertoUpdateLSCY Arm Cavity Transfer Function

    
        
 YarmTF02.png 
  2189   Fri Nov 6 00:40:29 2009 AlbertoUpdateLSCEverything put back as it wasI disconnected the setup for the arm cavity
TF measurement. I opened the scitation switch
on the ISS medm screen. I reconnected the
  
  2190   Fri Nov 6 07:55:59 2009 steveUpdateComputersRFMnetwork is downThe RFMnetwork is down.  MC2 sus damping
restored.
  
  2192   Fri Nov 6 10:35:56 2009 josephbUpdateComputersRFM reboot fest and re-enabled ITMY coil driversAs noted by Steve, the RFM network was
down this morning.  I noticed that c1susvme1
sync counter was pegged at 16384, so I decided
  
  2193   Fri Nov 6 12:56:30 2009 HaixingUpdateSUSMagnet has been levitated  

 DSC_0964.JPGblock_diagram.PNG 
  2194   Fri Nov 6 16:27:15 2009 JenneUpdatePEMRanger movedThe Ranger seismometer has been moved to
~the middle of the Mode Cleaner tube, and
it's orientation has been changed to horizontal
  
  2196   Fri Nov 6 18:02:22 2009 josephbUpdateComputersElog restartedWhile I was writing up an elog entry, the
elog died again, and I restarted it. 
Not sure what caused it to die since no one
  
ELOG V3.1.3-