  2332   Wed Nov 25 14:29:08 2009 robUpdateLockingMeasured MC length--FSS trend

    
        
 FSStrendpowerjump.png 
  2333   Wed Nov 25 15:38:08 2009 robUpdateLockingMeasured MC length

    
        
  
  2334   Wed Nov 25 15:42:27 2009 AlbertoUpdateABSLWorking on the AP table


   
        
            
  
  2335   Wed Nov 25 16:13:27 2009 ranaUpdatePSLMeasured MC length--FSS trendbut the increase in both the RCtrans and
the RCrefl is consistent with my theory that
the power going to the RC has increased ;
  
  2336   Wed Nov 25 16:44:52 2009 KojiUpdatePSLMeasured MC length--FSS trendI checked C1:PSL-FSS_VCODETPWR. The attached
is the 4 months trend of the FSS RCTRANS
/ RFPDDC(=FSS REFL) / VCODETPWR / VCOMODLEVEL.
 091125_FSS.png 
  2337   Wed Nov 25 20:14:58 2009 AlbertoUpdateABSLAbsL PLL not able to lock: problem fixed

    
        
  
  2338   Wed Nov 25 20:24:49 2009 AlbertoUpdateABSLPLL Open Loop Gain MeasuredI measured the open loop gain of the PLL
in the AbsL experiment.
I repeated the measurement twice:
 2009-09-25_OLgain_g3png.png2009-09-25_OLgain_g6png.png 
  2339   Wed Nov 25 20:28:17 2009 AlbertoUpdateABSLStopped working on the AbsLI closed the shutter of the NPRO for the
night.
  
  2340   Wed Nov 25 20:44:48 2009 kiwamuUpdateElectronicsMulti-resonant EOM --- Q-factor ----Now I am studying about the behavior of
the Q-factor in the resonant circuit because
the Q-factor of the circuit directly determine
 trans.pngeq1.pngimpedance.pngeq2.png 
  2341   Thu Nov 26 02:08:34 2009 KojiUpdateElectronicsMulti-resonant EOM --- Q-factor ----The key point of the story is:
"The
  
  2342   Fri Nov 27 02:25:26 2009 ranaUpdateABSLPLL Open Loop Gain Measured


   
        
            
  
  2343   Sat Nov 28 20:27:12 2009 KojiUpdatePSLFSS oscillation: Total gain reducedI stopped by the 40m for some reason and
found that the MC trans was 7.5.
This was caused by an oscillation
 091128_PSL.png 
  2347   Mon Nov 30 11:45:54 2009 JenneUpdateComputersWireless is backWhen Alberto was parting the Red Sea this
morning, and turning it green, he noticed
that the wireless had gone sketchy.
  
  2348   Mon Nov 30 16:23:51 2009 JenneUpdateComputersc1omc restartedI found the FEsync light on the OMC GDS
screen red.  I power cycled C1OMC, and
restarted the front end code and the tpman. 
  
  2349   Mon Nov 30 19:23:50 2009 JenneUpdateMZMZ downCame back from dinner to find the Mach
Zehnder unlocked.  The poor IFO is kind
of having a crappy day (computers, MZ, and
  
  2351   Fri Dec 4 18:54:03 2009 JenneUpdatePEMRanger movedThe Ranger was left in a place where it
could be bumped during next week's activities
(near the crawl-space to access the inside
 RangerSeismometer_SR560settings_4Dec2009.JPG 
  2352   Fri Dec 4 21:48:01 2009 JenneUpdateoplevsOplevs centered, IP_POS and IP_ANG centered[Jenne Koji]
 We aligned the full IFO, and
centered all of the oplevs and the IP_POS
 Oplev_IPang_screenshot_4Dec2009.png 
  2353   Fri Dec 4 23:17:55 2009 robUpdateoplevsOplevs centered, IP_POS and IP_ANG centered


   
        
            
  
  2354   Sat Dec 5 01:40:11 2009 KojiUpdateoplevsOplevs centered, IP_POS and IP_ANG centeredWe restarted daqd and
it did restored the problem
http://lhocds.ligo-wa.caltech.edu:8000/40m/Computer_Restart_Procedures#fb40m
  
  2357   Sat Dec 5 17:34:30 2009 robUpdateIOOfrequency noise problemThere's a large broadband increase in the
MC_F spectrum.  I'm not totally sure
it's real--it could be some weird bit-swapping
 mcf.png 
  2358   Sat Dec 5 18:23:48 2009 KojiUpdateoplevsOplevs centered, IP_POS and IP_ANG centeredNOTE: HEPA
is on at its full.
 Screenshot_091205_1830.png 
  2359   Sat Dec 5 22:31:52 2009 robUpdateIOOfrequency noise problem

    
        
  
  2360   Mon Dec 7 09:38:05 2009 KojiUpdateVACVent startedSteve, Jenne, Koji
The PSL was blocked by the
  
  2361   Mon Dec 7 18:18:55 2009 JenneUpdateCOCETMX drag wiped[Koji, Jenne, Alberto, Steve, Bob]
ETMX has
  
  2362   Mon Dec 7 19:02:22 2009 MottUpdateGeneralReflectivity Measurements I have made some measurements of the R
value for some coatings we are interested
in.  The plots have statistical error
 Y1-45P_R.pngY1-45S_R.pngY1-50CC_R.png 
  2363   Tue Dec 8 03:53:49 2009 kiwamuUpdateSUSFree swinging spectra of ETMX In this night, I checked the free swinging
spectra of ETMX to make sure nothing wrong
with ETMX by the wiping.
 ETMX_air.png 
  2364   Tue Dec 8 09:18:07 2009 JenneUpdateComputersA *great* way to start the day....Opening of ETMY has been put on hold to
deal with the computer situation.  Currently
all front end computers are down.  The
  
  2366   Tue Dec 8 13:03:26 2009 KojiUpdateCOCETMY drag wipedJenne, Kiwamu, Alberto, Steve,   
  2367   Tue Dec 8 16:27:13 2009 JenneUpdateCOCITMX wipedJenne, Kiwamu, Koji, Alberto, Steve, Bob
ITMX
  
  2368   Tue Dec 8 23:13:32 2009 kiwamuUpdateSUSfree swinging spectra of ETMY and ITMXThe free swinging spectra of ETMY and ITMX
were taken after today's wiping, in order
to check the test masses.
 SUS-ETMY.pngSUS-ITMX.png 
  2369   Wed Dec 9 00:23:28 2009 KojiUpdateSUSfree swinging spectra of ETMY and ITMXWhere
is the plot for the trend?
It
  
  2370   Wed Dec 9 09:07:32 2009 steveUpdatePEMhigh seismic activityThe construction activity is shaking the
tables in the control room.  The compactor-
large remote controlled jackhammer is in
 seis24d.pngseis4h.pngP1050833.JPGP1050836.JPG 
  2371   Wed Dec 9 10:53:41 2009 josephbUpdateCamerasCamera client wasn't able to talk to server on port 5010, reboot fixed it.I finally got around to taking a look at
the digital camera setup today.  Rob
had complained the client had stopped working
  
  2372   Wed Dec 9 17:51:03 2009 kiwamuUpdateSUSwatchdogsPlease do not touch
the watchdogs for all SUSs except for MCs,
  
  2373   Wed Dec 9 18:01:06 2009 KojiUpdateCOCWiping finished[Kiwamu, Jenne, Alberto, Steve, Bob,
Koji]
We
  
  2374   Wed Dec 9 21:09:28 2009 kiwamuUpdateSUSRe: free swinging spectra of ETMY and ITMXOkay, now the data are attached. At that
time I just wanted to say like the follower.
- - -
 Pitch-Yaw_modes.png 
  2375   Thu Dec 10 00:46:15 2009 KojiUpdateSUSRe: free swinging spectra of ETMY and ITMXWell, I get the point now. It could
be either seismic or change in the suspension
Q.
  
  2376   Thu Dec 10 08:40:12 2009 AlbertoUpdateComputersFronte-ends downI found all the front-ends, except for
C1SUSVME1 and C0DCU1 down this morning. DAQAWG
shows up green on the C0DAQ_DETAIL screen
  
  2378   Thu Dec 10 08:50:33 2009 AlbertoUpdateComputersFronte-ends down

    
        
  
  2379   Thu Dec 10 09:51:06 2009 robUpdatePSLRCPID settings not savedKoji, Jenne, Rob
 
We found that the RCPID servo "setpoint"
  
  2381   Thu Dec 10 09:56:32 2009 KojiUpdatePSLRCPID settings not savedNote: The set point C1:PSL-FSS_RCPID_SETPOINT
is 37.0 on C1PSL_FSS_RCPID.adl.
Now the temp is recovering with its
 RC_TEMP.png 
  2382   Thu Dec 10 10:01:16 2009 JenneUpdateComputersFronte-ends downAll the front ends are back up.  

  
  2383   Thu Dec 10 10:31:18 2009 JenneUpdateComputersFronte-ends down

    
        
  
  2385   Thu Dec 10 13:13:08 2009 JenneUpdateComputersfb40m backup restartedThe frame builder was power cycled during
the morning bootfest.  I have restarted
the backup script once more.
  
  2386   Thu Dec 10 13:50:02 2009 JenneUpdateVACAll doors on, ready to pump[Everybody:  Alberto, Kiwamu, Joe,
Koji, Steve, Bob, Jenne]
The last heavy door was put on after
  
  2387   Thu Dec 10 15:18:55 2009 JenneUpdateVACseisBLRMSlast 20 days - including the pounding from
next door
 Untitled.png 
  2388   Thu Dec 10 16:51:35 2009 steveUpdateVACpumpdown will start tomorrow morningThe vacuum system is at 760 torr 
All chambers with doors on and their annuloses
are pumped down.
  
  2391   Thu Dec 10 17:13:36 2009 kiwamuUpdateSUSFree swiging spectra under the atmospheric pressureThe free swinging spectra of ITMs, ETMs,
BS, PRM and SRM were measured last night
in order to make sure that nothing wrong
 summary_freeswing.pdf 
  2392   Thu Dec 10 18:27:48 2009 MottUpdateGeneralUpdated R & T MeasurementsAttached are updated plots of the T&R
Measurements for a variety of mirrors, and
diagrams for the setup used to make the measurements.
 6x 
  2401   Fri Dec 11 17:36:37 2009 kiwamuUpdateGeneralIFO restoring planAlberto,
Jenne, Kiwamu
 
  