40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 102 of 341  Not logged in ELOG logo
Entry  Thu Mar 10 01:31:37 2011, Kevin, Update, Electronics, AS55 Characterizations 
Entry  Thu Mar 10 17:03:48 2011, Larisa Thorne, Configuration, Electronics, calculations for passive low pass filter on X arm 
Entry  Wed Mar 23 16:06:20 2011, Larisa Thorne, Update, Electronics, Update on cable laying 
Entry  Tue Mar 29 15:01:58 2011, Larisa Thorne, Update, Electronics, Low pass filter for X arm laser temperature control DSC_2889.JPGLPFgraph.pdf
    Reply  Tue Mar 29 15:50:21 2011, Koji, Update, Electronics, Low pass filter for X arm laser temperature control 
Entry  Wed Mar 30 02:55:02 2011, Suresh, Configuration, Electronics, RF System : Status and Plans 
Entry  Wed Apr 6 16:02:07 2011, Larisa Thorne, Update, Electronics, Cable laying...continued 
    Reply  Mon Apr 11 09:49:53 2011, rana, Update, Electronics, New Green PD test1 
    Reply  Mon Apr 11 11:34:05 2011, Koji, Update, Electronics, New Green PD test1 SGD444A_240_test.png
    Reply  Mon Apr 11 20:03:05 2011, tara, Update, Electronics, TTFSS for 40m 
    Reply  Mon Apr 11 21:13:15 2011, Koji, Update, Electronics, New Green PD test1 
Entry  Wed Apr 13 16:38:17 2011, Larisa Thorne, Update, Electronics, Video MUX camera/monitor check 
Entry  Fri Apr 15 13:40:00 2011, Larisa Thorne, Update, Electronics, Low pass filter for X arm laser temperature control, second try Bode2.jpegBode100k.jpg
Entry  Tue Apr 26 01:20:02 2011, rana, Update, Electronics, POX_11 debugging 
    Reply  Tue Apr 26 22:03:49 2011, rana, Update, Electronics, POX_11 debugging MM7.png
Entry  Wed Apr 27 15:34:38 2011, kiwamu, Update, Electronics, AS55 demod board with new 90 deg splitter : healthy 
    Reply  Wed Apr 27 17:38:01 2011, kiwamu, Update, Electronics, Re : AS55 demod board with new 90 deg splitter : healthy relativephase.pngIQamplitude.png
Entry  Mon May 2 21:14:55 2011, kiwamu, Update, Electronics, too loose Heliax connectors on 1Y2 rack DSC_2982_ss.jpgDSC_2984_ss.jpg
    Reply  Mon May 2 23:29:57 2011, Suresh, Update, Electronics, too loose Heliax connectors on 1Y2 rack 
Entry  Tue May 3 14:35:44 2011, Larisa Thorne, Configuration, Electronics, Jenne-Seismometer LPF project SeisLPFdiagram.jpgseisLPF.Bose.jpg
Entry  Tue May 3 15:48:26 2011, Larisa Thorne, Update, Electronics, laser temperature control LPF, final version! LPF100k.2.jpg
    Reply  Tue May 3 17:19:25 2011, kiwamu, Update, Electronics, Heliax connectors on 1Y2 rack : tightened 
Entry  Wed May 4 17:32:06 2011, Larisa Thorne, Configuration, Electronics, Jenne-Seismometer LPF project SeisLPF3.jpg
Entry  Thu May 5 12:01:53 2011, Larisa Thorne, Configuration, Electronics, Jenne-Seismometer LPF project STS2diagram.png
Entry  Wed May 11 10:49:16 2011, valera, Configuration, Electronics, MC3 LL PD has no signal 
Entry  Wed May 11 16:04:36 2011, Larisa Thorne, Configuration, Electronics, Jenne-Seismometer LPF project STS2diagram2.png
    Reply  Wed May 11 17:10:04 2011, kiwamu, Configuration, Electronics, fixed : MC3 LL PD has no signal looseconnectionMC3.png
Entry  Mon May 16 17:11:28 2011, steve, Update, Electronics, strain relieved 1X1 P1070724.JPG
Entry  Wed May 18 18:48:46 2011, kiwamu, Update, Electronics, identification of RFPD interface cables 
Entry  Thu May 19 03:13:54 2011, kiwamu, Update, Electronics, REFL11 not working 1305799561ZgerKtrd.gif
    Reply  Fri May 20 11:37:44 2011, Koji, Update, Electronics, REFL11 fixed (REFL11 not working) REFL11_transimpedance.pdf
Entry  Sat May 21 17:02:38 2011, Koji, Update, Electronics, Alberto's 11MHz was modified to POP55MHz POP55_schematic_110520_KA.pdfPOP55_transimpedance.pdf
Entry  Tue May 31 16:07:57 2011, Larisa Thorne, Configuration, Electronics, Seismometer Box Update SeisBoxLISOplot1.pdfSeisBoxLISOplot2.pdfSTS2diagram_original.pdf
    Reply  Wed Jun 1 13:33:22 2011, koji, tara, Update, Electronics, TTFSS #7  q4.png
    Reply  Thu Jun 2 23:10:10 2011, Koji, Update, Electronics, REFL11 test results (Re: REFL11 fixed) REFL11_test.pdf
    Reply  Fri Jun 3 14:27:32 2011, Koji, Update, Electronics, POP55 test results POP55_test.pdf
Entry  Sat Jun 4 15:26:04 2011, Larisa Thorne, Update, Electronics, Seismometer Box Update SeisBoxLISO_transfer.pdfSeisBoxLISO_noise.pdf
Entry  Mon Jun 6 02:09:39 2011, rana, Update, Electronics, POY11 Rework Nearly Complete 777.png
    Reply  Mon Jun 6 16:44:34 2011, Koji, Update, Electronics, POY11 tested POY11_test.pdf
Entry  Fri Jun 10 20:23:56 2011, Larisa Thorne, Update, Electronics, Seismometer Box Update/graphs SeisNoiseGraphs.jpg
    Reply  Mon Jun 13 16:27:10 2011, Jenne, Update, Electronics, Seismometer Box Update/graphs NewSeisBoxNoise.png
Entry  Fri Jun 17 00:17:26 2011, rana, Configuration, Electronics, 2 RFPDs sent to LLO P1070895.JPG
Entry  Tue Jun 28 15:23:21 2011, steve, Update, Electronics, Coilcraft RF-design kits are restocked P1070917.JPGP1070915.JPG
Entry  Sat Jul 16 18:54:05 2011, Ishwita, Manuel, Configuration, Electronics, AA board DSC_3236.JPGpic1.pngDSC_3237.JPG
Entry  Wed Jul 20 22:16:27 2011, Ishwita, Manuel, Update, Electronics, lying seismometer cable and plugging it 
Entry  Sun Jul 24 20:36:03 2011, haixing, Summary, Electronics, AA filter tolerance analysis 6x
    Reply  Sun Jul 24 20:47:21 2011, rana, Summary, Electronics, AA filter tolerance analysis 
    Reply  Sun Jul 24 22:19:19 2011, haixing, Summary, Electronics, AA filter tolerance analysis low_pass_new.png
Entry  Mon Jul 25 23:43:20 2011, Manuel, HowTo, Electronics, Manual for 1201 Low Noise Preamplifier ITHACO_1201_Instruction_&_Maintenance.pdfDSC_3249.png
    Reply  Tue Jul 26 21:11:40 2011, haixing, Summary, Electronics, AA filter tolerance analysis 
ELOG V3.1.3-