  3392   Tue Aug 10 15:23:35 2010 JennaUpdateElectronicsRubidium clock time constant[Jenna & Alastair]
We changed the locking time constant
on one of the Rubidium clocks using the RbMon
  
  3393   Tue Aug 10 16:55:38 2010 JennaUpdateElectronicsc1iovme restarted Alastair
and I restarted the c1iovme around the time
of my last elog entry (~3:20).
  
  3398   Wed Aug 11 12:58:56 2010 JennaUpdateElectronicsRubidium clock phase noiseI took some measurements of the clock this
morning, first without the box, then with
the box, then without the box again. All
 08_11_Rb_crazybox.pdf08_11_Rb_comparison.pdf 
  3400   Wed Aug 11 15:27:16 2010 JennaUpdateElectronicsRubidium clock phase noiseWe unsynched the clocks by unhooking the
1pps locking. I've added it to the plot of
the other measurements here, and we've divided
 08_11_Rb_withspec.pdf 
  3402   Wed Aug 11 16:38:02 2010 JennaUpdateElectronicsRubidium clock phase noise


   
        
            
  
  3409   Thu Aug 12 16:18:00 2010 JennaUpdateElectronicsRb clocks overnightI took a look at the data from the middle
of the night to see if it was significantly
quieter than the data from the day, but it
 rbcomp.pdf 
  3423   Fri Aug 13 20:58:20 2010 JennaSummaryElectronicsRubidium clock phase noise measurement Here's an overview of the rubidium
measurement:
 6x 
  3450   Fri Aug 20 16:41:43 2010 AlbertoUpdateElectronicsFrequency Generation Box Assembly CompletedI finished assembling the frequency generation
unit for the upgrade. I tested it through
to check that the power levels are as expected
 7x 
  3484   Sat Aug 28 08:17:51 2010 AbertoUpdateElectronicsFSS Frequency Generation Box under testI've taken the FSS frequency generation
box out of the 1Y1 rack. It's sitting on
one of the electronics benches. I'm measuring
  
  3499   Tue Aug 31 17:58:38 2010 AlbertoUpdateElectronicsFSS Frequency Generation Box - Phase NoiseA few weeks ago, on Jul 24, Rana and I
measured the phase noise of the FSS frequency
box (aka the 'Kalmus Box'). See elog entry
 2010-08-31_FSSPhaseNoise04modified.png 
  3501   Wed Sep 1 07:52:27 2010 AlbertoConfigurationElectronicsPMC board unplugged, turned on Sorensen switches on 1Y1 rackToday I put the FSS frequency box back
into the 1Y1 rack.
To power it on, I turned on the 24V
  
  3504   Wed Sep 1 08:40:28 2010 AlbertoConfigurationElectronicsPMC board unplugged, turned on Sorensen switches on 1Y1 rack


   
        
            
  
  3506   Wed Sep 1 11:34:39 2010 AlbertoUpdateElectronicsFSS Box Phase Noise from DAQI measured the phase noise of the LO output
of the FSS box from the DAQ. I'm attaching
the results.
 2010-09-01_FSSPhaseNoise.png2010-09-01_FSSphaseNoiseMeasurementSetup.png 
  3508   Wed Sep 1 12:34:14 2010 ranaUpdateElectronicsFSS Box Phase Noise from DAQThe differences between this setup and
the one used previously is the lack of the
50 Ohm terminator in the mixer output and
  
  3509   Wed Sep 1 16:29:28 2010 AlbertoUpdateElectronicsFSS Box Phase Noise from DAQ - Measurement setup modified


   
        
            
 2010-09-01_FSSPhaseNoise_DAQ_00-02_comparison.png2010-09-01_FSSPhaseNoise_DAQ_02.pngFSSphaseNoiseMeasurementSetup02.png 
  3510   Wed Sep 1 17:17:42 2010 ranaUpdateElectronicsFSS Box Phase Noise from DAQ - Measurement setup modifiedWith the setup now working, we should now
test the power filtering for the crystal
and amplifier.
  
  3520   Fri Sep 3 11:03:41 2010 AlbertoFrogsElectronicsCable cutting toolsI found this very interesting German maker
of cool cable cutting tools. It's called
Jokari.
  
  3522   Fri Sep 3 13:04:30 2010 KojiFrogsElectronicsCable cutting toolsYeah, this looks nice.
And I also like to have something
I have attached. This is "HOZAN P-90",
 P90.jpg 
  3529   Mon Sep 6 22:09:11 2010 AlbertoUpdateElectronicsRF Frequency Generation Box heat sink installed and testedLast week I noticed that the high power
amplifiers in the Frequency Generation Box
became hot after 2 hours of continuous operation
 DSC_2467.JPG2010-09-06_FreqBoxAmplifierTemperatureTrend.pngDSC_2433.JPG 
  3530   Tue Sep 7 08:56:00 2010 AlbertoUpdateElectronicsFrequency Generation Box Assembly - Phase Noise MeasurementsHere are the results of my phase noise
measurements on the 7 outputs of the Frequency
Generation Box. (BIN=95L applied by DTT).
 2010-09-03_FreqBoxPhaseNoise_AllOutputsComparison_smooth.png2010-09-03_FreqBoxPhaseNoise_AllOutputsComparison_smooth.pdf 
  3532   Tue Sep 7 13:31:49 2010 AlbertoUpdateElectronicsRF System - Frequency Distribution Box - Priority PlanWe need a distribution unit in the LSC
rack to: 1) collect the demod signals coming
from the Frequency Generation Box 2) adjust
 Visio-RFsystem_plan_distributiont.pngRFsystem_plant_distribution_priority.png 
  3552   Thu Sep 9 12:02:03 2010 AlbertoUpdateElectronicsFrequency Generation Box - Amplitude Noise MeasurementsI measured the amplitude noise of the source
outputs and the EOM outputs of the Frequency
Generation box.
 FreqBoxAmplitudeNoiseMeasurementSetup.pngFreqBoxAmplitudeNoise_BusbyBox_AllChannels.png 
  3555   Thu Sep 9 18:53:56 2010 AlbertoConfigurationElectronicsBusby Box, Rai's Box, SR554 in the RF cabinetI stored the Busby Box, the Rai's Box and
the SR554 preamp in the RF cabinet down the
Y arm.
  
  3565   Mon Sep 13 11:40:50 2010 AlbertoUpdateElectronicsFrequency Box Documentation Added to the SVNI uploaded all the material about the RF
frequency Generation Box  into the SVN under
the path:
 freqBoxSVNdierctoryStructure.png 
  3572   Tue Sep 14 18:07:41 2010 AlbertoUpdateElectronicsFrequency Box Documentation Added to the SVNI completed a LIGO document describing
design, construction and characterization
of the RF System for the 40m upgrade.
  
  3596   Thu Sep 23 02:23:04 2010 koji,taraSummaryElectronicsTesting new TTFSS I tested the new table top
frequency stabilization system(TTFSS), 
  
  3604   Fri Sep 24 00:56:35 2010 koji, taraUpdateElectronicstesting TTFSSWe
found that a transistor was broken from yesterday
spark too. We partially fixed TTFSS, and
  
  3607   Fri Sep 24 23:47:10 2010 koji, taraUpdateElectronicstesting TTFSS  Q3, a PZT2222A transistor,
on D0901846 is replaced by a GE-82. However,
the board is still not fully function.
  
  3608   Sat Sep 25 19:01:13 2010 KojiUpdateElectronicstesting TTFSSHow much current do you need for each voltages?
GE-82 was the only PNP transister
I could find in the lab. It's too old but
  
  3617   Tue Sep 28 21:11:52 2010 koji, taraUpdateElectronicsFixing the new TTFSSWe
found a small PCB defect which is an excess
copper shorting circuit on the daughter board,
 before.jpgafter.jpgbefore.jpgafter.jpg 
  3655   Tue Oct 5 18:27:18 2010 Joonho LeeSummaryElectronicsCCD cable's impedenceToday
I checked the CCD cables which is connected
to the VIDEOMUX.
  
  3694   Mon Oct 11 23:55:25 2010 Joonho LeeSummaryElectronicsCCD cables for output signalToday
I checked all the CCD cables which is connected
output channels of the VIDEOMUX.
  
  3739   Mon Oct 18 22:11:32 2010 Joonho LeeSummaryElectronicsCCD cables for input signalToday
I checked all the CCD cables which is connected
input channels of the VIDEOMUX.
  
  3740   Tue Oct 19 00:24:07 2010 DmassOmnistructureElectronicsMassive restocking of the 40mI had a number of delinquent items on the
sign out list from the 40m. I returned about
half, and ordered replacements for most of
  
  3762   Fri Oct 22 16:59:21 2010 JenneUpdateElectronicsEpic TakeoverAs the suspension work winds down (we'll
be completely done once the ETMs arrive,
are suspended, and then are placed in the
  
  3764   Fri Oct 22 18:22:27 2010 AlbertoUpdateElectronicsEpic Takeover


   
        
            
  
  3773   Sun Oct 24 19:55:50 2010 kiwamuUpdateElectronicslonely RF amplifier on ITMX table(Rana, Kiwamu) 



  
  3782   Tue Oct 26 01:53:21 2010 Joonho LeeUpdateElectronicsFuction Generator removed.Today
I worked on how to measure cable impedance
directly.
  
  3792   Wed Oct 27 09:02:29 2010 steveUpdateElectronicsHP4195A is NOT fixedwww.avalontest.com has fixed the 25MHz
oscillation.  Contact: Jim Burnham 760-536-0191
  
  3812   Thu Oct 28 19:10:26 2010 taraUpdateElectronicsTTFSS for 40mI keep a set of new TTFSS for 40m in electronic
cabinet along the North arm.
The set number is #6. It is working
  
  3858   Wed Nov 3 23:58:45 2010 ranaUpdateElectronicsCougarsI looked at this web page: http://www.teledyne-cougar.com/Index.asp
for the RF company that Rich has recently
started using.
  
  3871   Fri Nov 5 19:33:18 2010 JenneUpdateElectronicsThe beginnings of the new phase of the RF workJoon Ho and I took a look at the RF stuff
that Alberto left, and we determined that
we've got most everything that we need. 
  
  3890   Thu Nov 11 02:17:27 2010 KevinUpdateElectronicsREFL11 Photodiode Not Working[Koji and Kevin]
I was trying to characterize the
REFL11 photodiode by shining a flashlight
  
  3893   Thu Nov 11 07:26:03 2010 AlbertoUpdateElectronicsREFL11 Photodiode Not Working


   
        
            
  
  3904   Fri Nov 12 02:51:20 2010 KevinUpdateElectronicsPhotodiode Testing[Jenne and Kevin]
I started testing the REFL55 photodiode.
With a light bulb, I saw ~270 mV of DC voltage
  
  3911   Fri Nov 12 20:40:51 2010 josephb, yuta, valeraConfigurationElectronicsAA voltage rangeWe changed the range of the two SUS AA
boards in the corner from +/-2 V to +/-10
V by changing the supply voltage from +/-5
  
  3913   Sat Nov 13 16:57:21 2010 valeraConfigurationElectronicsPRM Side OSEM transimpedance changeNow that we have increased the range of
the AA to +/- 10 V I have increased the PRM
side OSEM transimpedance from 29 kV/A to
 PRM-SD-ADC.pdfPRM-SD-Current.pdf 
  3916   Sun Nov 14 16:26:31 2010 jenne, valeraUpdateElectronicsSRM side OSEM noise with no magnetWe realized that the SRM sensors are connected
to the readout but just sitting on the BS
in vacuum table with no magnets and therefore
 SRM-SD-Current-NoMagnet.pdf 
  3918   Mon Nov 15 04:57:10 2010 ranaUpdateElectronicsSRM side OSEM noise with no magnetIF I believe this calibration and IF I
believe that the noise is the same with no
magnet in there, then its almost 1
  
  3933   Tue Nov 16 15:32:18 2010 valeraUpdateElectronicsOSEM noise at the output of the satellite box I measured the SRM OSEM (no magnets
at the moment) noise out of the satellite
box with a SRS785 spectrum analyzer. I inserted
 osemnoise.pdf 