  7722   Sat Nov 17 22:50:17 2012 KojiUpdateAlignmentred in armsYou have constraints for the IR beams (i.e.
one PZT and one BS for 8 dofs), so now you
need to align the arms for the input IR beams.
  
  7728   Mon Nov 19 22:42:14 2012 KojiConfiguration40m UpgradingEndtable upgrade for auxiliary green laser : ETMX layout on new table
    I don't like the idea to
place the cylindrical lenses right in front
of the laser. 
  
  7735   Tue Nov 20 20:37:51 2012 KojiUpdateIOOMC autolockerLast night I found that the MC autolocker
has not been updated since the chamber was
closed.
  
  7737   Wed Nov 21 01:36:36 2012 KojiUpdateIOOMCL disabled / WFS clear history restoredAs MCL is disturbing arm locking by injecting
a lot of noise, I have modified 'mcup' 
to disable MCL
  
  7740   Sat Nov 24 22:14:08 2012 KojiUpdateGeneralAP table cleaning upOn Wednesday (21st) night, I checked the
AP table as I wanted to try PRMI locking. 
It was difficult to work with the
 APTable121124.pdfAPTable121124.graffle.zip 
  7741   Sat Nov 24 23:50:35 2012 KojiUpdateIOOMC WFS refusing to workToday I found the IMC was misaligned significantly
by WFS feedback.
Once the feedback was cleared, it
  
  7767   Fri Nov 30 11:49:24 2012 KojiUpdateAdaptive FilteringYARMThis is interesting. I suppose you are
acting on the ETMY.
Can you construct the compensation
  
  7785   Tue Dec 4 20:13:55 2012 KojiUpdateSUSTTs are readyPlease
leave here what was the instruction by Bran
  
  7811   Tue Dec 11 19:51:36 2012 KojiUpdatePSLPMC gain was too low / EPICS alerting value for PMC updated[Ayaka, Koji]
Ayaka pointed out that the PMC has
too low unity gain frequency. We checked
  
  7827   Fri Dec 14 02:52:32 2012 KojiUpdateSUSTT angle of incidenceAt least, we don't want to use Al-coated
mirrors. We should use multilayer dielectric
mirrors.
  
  7845   Mon Dec 17 22:42:27 2012 KojiSummaryGeneralThe projector lamp ended its life?i just heard a rather large exploding sound
in the control room.
I tried to locate the source and found
  
  7847   Tue Dec 18 00:45:19 2012 KojiSummaryGeneralThe projector lamp ended its life?...Nah.   
  7860   Wed Dec 19 21:35:33 2012 KojiSummaryGeneralFirst Contact Training with Margot[Koji, Steve]
First
Contact Training with Margot
  
  7871   Wed Jan 2 06:52:50 2013 KojiUpdateSUSTT in vac DB25 pin swapping[Koji, Rana, Nic, Steve]

I recalled that we used an optical
  
  7885   Wed Jan 9 13:34:34 2013 KojiSummaryGeneralThe projector lamp ended its life?[Koji, Manasa]
- A new projector lamp installed.
- The old lamp lasted 8751 "equivalent
  
  7894   Fri Jan 11 19:12:20 2013 KojiUpdateAlignmentTT2 connectionsWas the connection   
  7908   Wed Jan 16 19:08:51 2013 KojiSummaryIOONoise budget for MCI missed the point. 
Do you mean that we can measure the coating
  
  7918   Fri Jan 18 12:08:08 2013 KojiUpdateLockingDust?No


  
  7927   Tue Jan 22 19:51:52 2013 KojiUpdate Photodiode transimpedance- The data should be plotted in a log-log
scale.
- The data points were only taken
  
  7932   Wed Jan 23 20:24:05 2013 KojiUpdateGeneralLaseroptik mirror - SN6Got confused (even after I talked with
Manasa).
The plot shows the number ~0.01 or
  
  7941   Thu Jan 24 16:23:24 2013 KojiUpdateGeneralLaseroptik mirror - SN6The mirror T is completely out of spec.
We should find or request the data sheet
of the mirror.
  
  7953   Tue Jan 29 14:20:02 2013 KojiUpdateGeneralFiner rotation stage for optics characterizationA rotation stage has been ordered.

  
  7960   Wed Jan 30 03:01:55 2013 KojiUpdateGeneralEarly work on Mirror MountsI
can't believe that SR785 can have
such a low input noise level (<1nV/rtHz).
  
  7980   Thu Jan 31 23:48:45 2013 KojiUpdateLockingPRM/PR2 cavityWow! What's happened?   
  7987   Fri Feb 1 23:12:42 2013 KojiUpdateLockingPRM/PR2 cavityDuring the scanning we were riddled by
the fact the PDH error and the transmission
peaks do not happen simultaneously.
  
  7989   Sun Feb 3 13:20:02 2013 KojiSummaryGeneralHypothesisRana mentioned the possibility that the
PR2 curvature makes the impact on the mode
stability. Entry
 mode_density_PRC.pdfmode_density_PRC.zip 
  7991   Mon Feb 4 11:10:59 2013 KojiSummaryGeneralrough analysis of aligned PRM-PR2 mode scanThe expected finesse is 100ish. How much
can we beleive the measured number of 50?
From the number we need to assume
  
  7992   Mon Feb 4 15:06:56 2013 KojiSummaryGeneralHypothesis

    

       
            
  
  7998   Tue Feb 5 03:16:51 2013 KojiSummaryGeneralrough analysis of aligned PRM-PR2 mode scan0.764 and 0.751 do not give us the stdev
of 0.005.
I have never seen any Yokogawa in
  
  8002   Tue Feb 5 11:30:19 2013 KojiSummaryGeneralrough analysis of aligned PRM-PR2 mode scanMakes sense. I mixed up n and n-1
Probability function: X = (x1 + x2
+ ... + xn)/n, where xi = xavg +/- dx
  
  8025   Thu Feb 7 17:10:11 2013 KojiSummaryGeneralPRC/arm mode matching calculations

    

       
            
  
  8031   Fri Feb 8 02:38:04 2013 KojiUpdateLockingPRMI workI feel it's too hasty to use the PRMI.

I support the idea of the  half-PRC
  
  8042   Fri Feb 8 19:39:02 2013 KojiUpdateLockingPRMI workIt seems that the cavity trans looks much
better than before. Cool.
  
  8044   Fri Feb 8 20:27:56 2013 KojiUpdateRF SystemMC REFL Photodiode transimpedanceThe comment itself was added by me. 
The difference between the previous
  
  8046   Fri Feb 8 22:49:31 2013 KojiUpdateOpticsG&H - AR Reflectivity How about to measure the AR reflectivity
at larger (but small) angles the extrapolate
the function to smaller angle, 
  
  8050   Sat Feb 9 11:25:35 2013 KojiUpdateLockingPR2-flipped half-PRC mode scanDon't  Shouldn't you
apply a small misalignment to the input beam?
Isn't that why the peak for the 1st-order
  
  8060   Mon Feb 11 17:54:02 2013 KojiSummaryOpticsCurvature radii of the G&H/LaserOptik mirrorsI, by chance, found  that my windows
partition has Vision32 installed.
So I run my usual curvature characterization
 TT_Mirrors_RoC.pdf 
  8079   Wed Feb 13 19:30:45 2013 KojiSummaryGeneralpossible explanations to oval REFL beam>> "What has changed since:"
Recently
the REFL path has been rearranged
  
  8089   Fri Feb 15 16:09:19 2013 KojiUpdateGeneralbeam traps ready to be installedFor the hexagonal one, insert one of the
glass plate only half. Use a 1"x.5"
piece if exists.
 HexBeamDump.pdfDiamondBeamDump2in.pdf 
  8100   Mon Feb 18 21:43:05 2013 KojiUpdateAlignmentPOP path set up but AS55 is brokenI undertook the investigation of the AS55
PD.
I found the PD is not broken.
 AS55.pdf 
  8104   Tue Feb 19 05:42:28 2013 KojiUpdateElectronicsPOP path set up but AS55 is broken10010 Ohm for POP55 vs 50 Ohm for AS55
(cf. http://nodus.ligo.caltech.edu:8080/40m/4763)
I
  
  8106   Tue Feb 19 08:42:31 2013 KojiUpdateVACETMX door open[Steve, Yuta, Koji]
The ETMX heavy door was removed.
  
  8134   Thu Feb 21 21:12:42 2013 KojiUpdateVACpumpdown at 230 Torr[Rana, Yuta, Koji]
21:05 at the pressure of 10torr
V3 closed. RV1 manually closed. RPs
  
  8144   Sat Feb 23 14:04:07 2013 KojiUpdateComputersapache retarted (Re: linux1 dead, then undead)apache has been restarted. 
How to: search "apache"
on the 40m wiki
  
  8156   Mon Feb 25 13:01:39 2013 KojiSummaryGeneralQuick, compact, and independent tasks- IMC PDH demodulation phase adjustment
- Permanent setup for green transmission
DC PDs  on the PSL table
  
  8166   Tue Feb 26 02:04:51 2013 KojiUpdateLockingPRMI lockedOne of the biggest issues we had was that
any Q signals (i.e. the quadrature where
PRCL is absent.) of REFL11/33/55/(165) haven't
  
  8187   Wed Feb 27 18:01:46 2013 KojiUpdate Photodiode transimpedanceHow
much is the exact resonant frequency?
And 
  
  8198   Thu Feb 28 03:41:31 2013 KojiUpdateLSCPR gain ~ 25 from PRMI carrier lockVERY
GOOD! 
This is how the carrier lock PRMI
  
  8239   Wed Mar 6 09:44:29 2013 KojiUpdateLSCPRMI locking for g-factor measurement- What about normalizing POPDC to indicate
the carrier recycling gain?
- When you align the PMC, confirm
  
  8247   Wed Mar 6 22:11:19 2013 KojiUpdateElectronicsPOX whitening was fine all alongAt the time you, den and I worked together,
we could not lock the X-arm on TEM00 with
the FM1s of the POX11 on.
  