  6146   Thu Dec 22 20:49:33 2011 KojiUpdateIOOLimitter activated for WFS servosI set the limitters of the MC WFS servos
not to inject the feedback more than 2000.
The residual of the WFS shakes the
  
  6160   Tue Jan 3 17:25:27 2012 KojiUpdatePSLFound the laser was offI found the PSL laser has been off for
four hours. Nobody seemed to know why.
I just turned it on and it is now
  
  6193   Thu Jan 12 23:13:42 2012 KojiConfigurationWIKI-40M UpdateUnable to create Wiki page

    
        
  
  6194   Thu Jan 12 23:19:56 2012 KojiUpdateSUSc1iscex is fine nowc1iscex
is working as before and the optic is damped.

What I checked
  
  6262   Thu Feb 9 13:04:11 2012 KojiSummaryIOOPMC/IMC alignmentThere
has been no lock of input MC for more than
5days. WTF???
 Untitled.pngUntitled2.png 
  6277   Mon Feb 13 12:02:17 2012 KojiUpdatePEMseismic BLRMS loud tooI reported the procedure to add slow channels
to the FB. I guess you already have done
Step.1
  
  6287   Thu Feb 16 07:38:24 2012 KojiUpdateLSCsensing matrix of PRMISo why don't you use AS55I and Q for the
control of PRMI???
  
  6359   Mon Mar 5 20:31:33 2012 KojiUpdateLSC22/110MHz path for POPThis a kind of self record...
We need an RF setup at POP to extract
22 and 110 MHz components separately.
  
  6366   Tue Mar 6 22:23:04 2012 KojiUpdateLSC22/110MHz path for POP 
 As par Kiwamu's request, RF
filters for POP22 and POP110 were installed.
  
  6374   Wed Mar 7 15:56:36 2012 KojiUpdateLSC22/110MHz path for POPThe RF separator installed comprises of
the Minicircuits filters cascaded as in the
figure below. 
 RFseparator.pngimpedance.pdftransmission.pdf 
  6379   Wed Mar 7 20:06:23 2012 KojiUpdateLSCREFL OSA : how the signal look likeI'm puzzled why the 11MHz peak can be such
high considering 1.7~2 times smaller the
modulation depth.
  
  6420   Wed Mar 14 23:02:09 2012 KojiUpdateLSCLocking activityKiwamu and Koji
The target is to realize DRMI or
PRMI + one arm with ALS.
  
  6421   Thu Mar 15 04:04:23 2012 KojiConfigurationLockingPRC Matching issuesKiwamu and Koji
We found that the intra-cavity mode
of the PRC is not round although it was obvious
 P3150910.jpgP3150902.jpgP3150906.jpgP3150907.jpgP3150900.jpg 
  6439   Thu Mar 22 23:43:56 2012 KojiUpdateCDSc1scx and c1scy not properly runningDid you guys checked if the simplant switch
is set to "REAL WORLD" mode?
  
  6453   Tue Mar 27 17:19:02 2012 KojiUpdateIOOBeam Profile measurement: IPPOS beamThe mode looks quite terrible in the plot,
but in reality it is an illusion of the plot.
  
  6455   Tue Mar 27 17:52:08 2012 KojiUpdateIOOAnother possibility / thoughtIt is quite likely that we touched the
Faraday in Nov 2010.
In this entry http://nodus.ligo.caltech.edu:8080/40m/3874
  
  6588   Mon Apr 30 21:24:43 2012 KojiUpdateSUSETMY oplev power supply deadAnd has the temp controller of the green
been recovered too? (Push enable button)
 
  
  6595   Thu May 3 13:07:05 2012 KojiBureaucracyGeneralInterferometer check-up sessionFrom 2PM, Jenne/Den/Koji. Finished at 10:30PM

    General
    

       More LCD screens! Wider screens!
  
  6598   Thu May 3 17:15:38 2012 KojiUpdateLSCc1iscaux2 rebooted/burtrestored[Jenne/Den/Koji]
We saw some white boxes on the LSC
screens.
  
  6600   Thu May 3 21:13:48 2012 KojiSummarySUSITMX/PRM/BS OPLEV aligned[Jenne/Den/Koji]
We locked Xarm/Yarm and manually
alignmed ITMX/ITMY/BS/ETMX/ETMY/PZT1/PZT2.
  
  6605   Sat May 5 09:13:02 2012 KojiUpdatePSLPMCI suspect that it was just unlocked when
you had disconnected the cable.
There is not reflection now. It seems
  
  6607   Sat May 5 12:23:38 2012 KojiUpdatePSLPMCNo matter how you connect/disconnect, touching
the laser may cause the PMC unlocked.
At
  
  6614   Mon May 7 19:39:52 2012 KojiUpdateIOOWFS noise in MCOK. Then we should make this number bigger
such that the coherence is still completely
maintained.
  
  6631   Wed May 9 09:19:22 2012 KojiUpdateLockingPRM is really moving when PRMI lockedIs this enhancement of spectrum caused
by the lock? Or by the actuation?
  
  6637   Thu May 10 14:49:06 2012 KojiHowToGeneralHow to clean & bake black glass pieces    
  6653   Mon May 21 19:16:55 2012 KojiUpdateGeneralrossa X configI rebooted rossa and the X sever has stalled.   
  6675   Thu May 24 14:49:59 2012 KojiSummaryGeneralDaily news ideaTop tab categolies:

    Summary
    CDS

   
        CDS Status
  
  
  6682   Fri May 25 16:10:53 2012 KojiUpdateGeneralStripTool on Zita restoredssh -X pianosa
On pianosa
  
  6690   Sat May 26 01:28:58 2012 KojiUpdateGeneralClipping improvementThe beam at the dark port was largely clipped.
The arm transmissions (TRX/TRY) were
~0.6 no matter how you try to align.
 Untitled.png 
  6704   Tue May 29 15:48:31 2012 KojiUpdateIOOPMC, MC alignment are shitThe followings are a kind of daily check.
Do this without any notice:
- Align PMC.
  
  6705   Tue May 29 15:49:02 2012 KojiUpdateLockingETMX trans camera

    

       
            
  
  6780   Thu Jun 7 07:27:27 2012 KojiUpdateGreen Lockingimproved Y arm green alignment - even moreYes.
The end PDH servo should be checked more
carefully.
 freq_noise_AUX.pdf 
  6786   Thu Jun 7 13:25:37 2012 KojiUpdateSUSPRM is still oscillatingDone.
C1:SUS-PRM_OLPIT_GAIN 1.0 -> 0
C1:SUS-PRM_OLYAW_GAIN -0.7 -> 0
  
  6820   Fri Jun 15 01:53:05 2012 KojiUpdateGreen Lockingscanned Y arm for 5FSRInteresting.
It seems for me that there is a dependence
of the noisiness as the beat frequency is
  
  6826   Sat Jun 16 18:51:44 2012 KojiUpdateGreen LockingY arm length using 5FSR scan

    

       
            
  
  6852   Fri Jun 22 03:37:42 2012 KojiUpdateGreen Locking2 arm ALS - Success!!!!Are
these correct?
1. It is a nice work.
  
  6870   Mon Jun 25 16:21:10 2012 KojiSummaryIOOSelection of motorized mirror mountsI am considering to have 3 to 6 motorized
optical mounts at the PSL and end tables
for remote beam steering.
  
  6887   Thu Jun 28 01:44:57 2012 KojiUpdateLockingPRMI work started, commissioning planTo be fair, this is Kiwamu's idea. And
nothing is reasonable before it is confirmed
quantitatively.
  
  6939   Sun Jul 8 00:58:08 2012 KojiSummaryLockingcalibrating phase tracking mode scan data

    

       
            
  
  6949   Tue Jul 10 01:52:47 2012 KojiUpdateLSCPRMI got more stable a bitThe phase margins looks still too small.
Do You need such high gain at LF?
This is not a high finesse cavity so can
  
  7009   Mon Jul 23 19:00:26 2012 KojiUpdateGreen LockingALS_END.mdl model added for end station green ALS channelsThis is a good modification. We just need
to check how the ALS scripts are affected.

  
  7033   Wed Jul 25 22:16:36 2012 KojiUpdateLSCringdown measurementIs this the step response of the single
pole low pass???
It should have an exponential decay,
  
  7061   Tue Jul 31 19:34:55 2012 KojiUpdateSTACISOpen loop gains and block diagramWith your definition of the open loop gain,
G=+1 is the condition to have singularity
in a closed loop transfer function 1/(1-G).
  
  7120   Wed Aug 8 13:37:46 2012 KojiUpdateComputer Scripts / ProgramsWeek 8/Summary Pages updateHey, the pages got significantly nicer
than before. I will continue to give you
comments if I find anything.
  
  7124   Wed Aug 8 20:50:39 2012 KojiUpdateASSTrouble measuring sensing matrixFrom the log, I couldn't understand what
has been done.
The procedure we should perform is
  
  7131   Thu Aug 9 01:26:03 2012 KojiUpdateASSTrouble measuring sensing matrixThat's a good point, but I suspect
that you end up with the in-phase (0deg)
as the response of the IFO is immediate compared
  
  7155   Sun Aug 12 10:34:45 2012 KojiUpdateSAFETYexit door left unlockedI unlocked the door on Tuesday in order
to move the red cart. 
After that I confirmed that the door
  
  7158   Mon Aug 13 09:59:05 2012 KojiUpdateGeneralMysterious banging on emergency doorYou mean 5000?


  
  7216   Fri Aug 17 09:34:27 2012 KojiUpdateCamerasvideo cameras in the darkI used the LED illuminations at ETMX and BS
yesterday for a tour.
I am afraid that I left them on.
  
  7264   Thu Aug 23 22:41:04 2012 KojiUpdateIOOMC Autolocker update[Koji Rana]
MC Autolocker was updated. (i.e.
mcup and mcdown were updated)
  