ID Date Author Type Category Subjectup Text Attachments
  12683   Fri Dec 23 20:53:44 2016 KojiSummaryIOOIMC WFS tuningWFS1 / WFS2 demod phases and WFS signal
matrix
 DSC_0144.JPGDSC_0145.JPG 
  12684   Fri Dec 23 21:05:56 2016 KojiSummaryIOOIMC WFS tuningSignal transfer function measurements

C1:SUS-MC*_ASCPIT_EXC channels
were excited for swept sine measurements.
 IMC_WFS_segment_TF.pdfIMC_WFS_channels_TF.pdfIMC_WFS_161221_table1.pdfIMC_WFS_161221_table2.pdfIMC_WFS_161221.xlsx.zip 
  12685   Sun Dec 25 14:39:59 2016 KojiSummaryIOOIMC WFS tuningNow, the output matrices in the previous
entry were implemented.
The WFS servo loops have been engaged
  
  12686   Mon Dec 26 12:45:31 2016 KojiSummaryIOOIMC WFS tuningIt didn't go crazy at least for the
past 24hours.
 IMC_REFL_TRANS_26hrs.pngIMC_TRANS_P_Y_26hrs.png 
  12688   Thu Dec 29 13:22:21 2016 ranaSummaryIOOIMC WFS tuning
For the rough calibration below
10 Hz, we can use the SUS OSEM cal: the SUSPIT
and SUSYAW error signals are in units of
  
  12689   Thu Dec 29 16:52:51 2016 KojiSummaryIOOIMC WFS tuningKoji responding to Rana

>
For the rough calibration below 10 Hz, we
  
  12690   Thu Dec 29 21:35:30 2016 ranaSummaryIOOIMC WFS tuningThe WFS gains are supposedly
maximized already. If we remotely try
to increase the gain, the two MAX4106 chips
 Screen_Shot_2017-01-03_at_5.55.13_PM.png 
  12669   Tue Dec 6 16:47:40 2016 KojiUpdateIOOIMC WFS whitening filter investigationThe
whitening board saids it is Rev B, but the
actual component values are more like Rev.
 D990196-C.pdf 
  12670   Tue Dec 6 17:54:08 2016 KojiUpdateIOOIMC WFS whitening filter investigationThe
input resistor 909Ohm of AD602 was shorted.
I've confirmed that the gain (= attenuation
 34.png 
  12671   Tue Dec 6 22:41:49 2016 KojiUpdateIOOIMC WFS whitening filter investigationI have implemented the same modification
(shorting the input resistor of AD602) to
the two whitening boards.
  
  12676   Tue Dec 13 17:26:42 2016 KojiUpdateIOOIMC WFS whitening filter investigationRana pointed out that this modification
(removal of 900Ohm) leave the input impedance
as low as 100Ohm.
  
  12678   Thu Dec 15 03:46:19 2016 ranaUpdateIOOIMC WFS whitening filter investigationhttps://dcc.ligo.org/LIGO-D1400414

As it turns out, its not so old
as I thought. Jenne and I reworked these
  
  17063   Fri Aug 5 12:42:12 2022 KojiUpdateIOOIMC WFS: Overnight observation The IMC lock survived overnight and the
WFS servo loops kept it aligned. The IMC
was unlocked in the morning.
 Screen_Shot_2022-08-05_at_12.04.01.png 
  14310   Tue Nov 20 13:13:01 2018 gautamUpdateVACIMC alignment is okayI checked the IMC alignment following the
vent, for which the manual beam block placed
on the PSL table was removed. The alignment
  
  15227   Wed Feb 26 22:05:06 2020 gautamUpdateIOOIMC checksToday, I did the following tests (and so
was touching electronics/cables at/around
1X2):
  
  15229   Wed Feb 26 23:50:51 2020 gautamUpdateIOOIMC checksIn the style of the KA characterization
of the CM board, the AO path gain EPICS slider
(IN2) of the IMC servo board was stepped
 sliderCal.pdfAO_inputTFs.pdf 
  16782   Fri Apr 15 11:59:16 2022 YehonathanUpdateIOOIMC completely misalignedCame this morning, opened the PSL and there
was not even a beam on the MC REFL.

Looking at the big monitor it seems
  
  14653   Tue Jun 4 10:56:31 2019 gautamUpdateIOOIMC diagnosticsI briefly managed to lock the IMC today
- it stayed locked for ~10 minutes. Attachment
#1 shows spectra of a few error and control
 IMCdiag.pdf 
  14659   Thu Jun 6 22:11:53 2019 KojiUpdateIOOIMC diagnosticsAs per Gautam's request, I looked at
the IMC situation.

Locking
  
  14670   Thu Jun 13 18:01:18 2019 aaronUpdateIOOIMC diagnosticsContinuing this investigation of the IMC,
today I am getting familiar with the PMC
and FSS. I'd like to measure the frequency
  
  14675   Fri Jun 14 13:10:00 2019 aaronUpdateIOOIMC diagnosticsThe circuit diagram for the PMC servo card
is D980352.
From this diagram, I see that I can send
  
  14677   Mon Jun 17 12:37:16 2019 aaronUpdateIOOIMC diagnosticsGrabbed the PMC data

I went
to set up the spectrum analyzer measurements
through GPIB, but inadvertently deleted the
  
  14681   Tue Jun 18 20:35:07 2019 aaronUpdateIOOIMC diagnosticsI made a script (/users/aaron/40m/GPIB/tds_dump.py)
that grabs data from a Tektronix scope and
packages into a pickled dict with the following
  
  14683   Wed Jun 19 19:12:51 2019 aaronUpdateIOOIMC diagnosticsHere are the results from the fit. Data
can be found on nodus in /users/aaron/40m/data/PMC/190617/.
I've put a jupyter notebook with
 PMC_Error_Spectrum.pdfPDH_signal.pdfPDH_signal_full.pdf 
  14686   Fri Jun 21 19:36:26 2019 KojiUpdateIOOIMC diagnosticsThe IMC REFL error signal was measured
to compare it with the other spectra (if
we have).
 IMC_error.pdf 
  14693   Mon Jun 24 15:49:05 2019 aaronUpdateIOOIMC diagnosticsaI went to repeat these measurements using
the mixer out channel from the servo box,
and with a slower sweep for the PDH calibration.
 sweep_config_updated.png 
  14721   Tue Jul 2 19:36:18 2019 aaronUpdateIOOIMC diagnosticsThe latest in my fling with the PMC. Though
PMC trans is back to nominal levels (~0.713
V), we'd still like to understand the
 PDH_error.pdfPMC_Error_Spectrum.pdf 
  11561   Thu Sep 3 00:14:09 2015 ranaConfigurationIOOIMC fast gain change for lock acqThe IMC often was making that scratchy
noise when first catching lock and sometimes
breaking. Thinking of the crappy crossover
  
  12751   Wed Jan 25 01:27:45 2017 gautamUpdateIMCIMC feedforward checkupThis is probably just a confirmation of
something we discussed a couple of weeks
back, but I wanted to get more familiar with
 IMC_FF_potential.pdf 
  11794   Sat Nov 21 00:45:30 2015 KojiUpdateIOOIMC fixBased on the observation of the PMC error
signal, I started measuring the IMC OLTF.
Immediately, it
 PDRFsignal_cable.JPGQsignal_cable1.JPGQsignal_cable2.JPGQsignal_cable3.JPG 
  11796   Sun Nov 22 07:09:01 2015 ranaUpdateIOOIMC fixOn the demod board there is a 10 dB attenuator
(AT1), which lowers the level to -10 dBm
before the ERA-5. Then it should be 10 dBm
  
  11797   Sun Nov 22 12:07:09 2015 KojiUpdateIOOIMC fixTO DO

Done (Nov 23, 2015) -
Check if the attenuator is still there in
  
  15897   Wed Mar 10 15:35:25 2021 Paco, AnchalSummaryIMCIMC free swinging experiment set to trigger at 5:00 amA tmux session named "MCFreeSwingTest"
will run on Rossa. This session is running
script scripts/SUS/freeSwingMC.py (also attached)
 freeSwingMC.py.zip 
  15893   Wed Mar 10 11:46:22 2021 Paco, AnchalSummaryIMCIMC free swinging prep[Paco, Anchal]

# Initial State
- MC is locked. The PRM monitor shows
  
  15895   Wed Mar 10 15:00:16 2021 gautamSummaryIMCIMC free swinging prepDid you fix this issue? It is helpful to
post a screenshot of the offending MEDM screen
in addition to witticisms. The elog says
  
  15896   Wed Mar 10 15:29:58 2021 AnchalSummaryIMCIMC free swinging prepNo we didn't fix the issue. We'll
post some screenshots tomorrow. From "sitemap>Shutter>PSL"
we meant in Shutter medm window, we clicked
  
  15546   Sat Aug 29 18:52:42 2020 ranaUpdateIOOIMC gain changeI lowered
the (FAST) PZT gain on the IMC/FSS servo
today.
  
  14691   Mon Jun 24 11:48:35 2019 gautamUpdateIOOIMC in-loop error spectra and OLTFAttachment
#1 - In loop
 IMCfreqNoise.pdfIMC_OLTF.pdfIMC_CMboard.jpg 
  12896   Tue Mar 21 15:13:44 2017 gautamUpdateIMCIMC input beam mode matching[valera, gautam]

Last night, Valera and I looked
into two aspects of the IMC:
 IMG_7220.JPGIMC_ModeMatch.pdfsingleLensSensitivity.pdfsensitivity.pdfIMCmodeMatch.m 
  12898   Tue Mar 21 21:59:48 2017 gautamUpdateIMCIMC input beam mode matching[valera, gautam]

We implemented the plan outlined
in the previous elog. The visibility (Pmax-Pmin)/(Pmax+Pmin) calculated
 IMG_3654.JPGIMG_3655.JPG 
  16886   Thu Jun 2 20:05:37 2022 yutaConfigurationPSLIMC input power recovered to 1W, some alignment works[Paco, Yuta]

We have
 Before.JPGAfter.JPG 
  14688   Sun Jun 23 09:36:32 2019 gautamUpdateIOOIMC is locking normally againAfter typing up the elog, I decided to
try locking the IMC again - now it locks
again with the "OLD" gain settings.
 PMCdiag.pdf 
  14689   Sun Jun 23 14:43:14 2019 KojiUpdateIOOIMC is locking normally againNote that I have removed an SR785, an oscilloscope,
some SRS instruments from the PSL and PMC
last night.
  
  14690   Mon Jun 24 08:12:10 2019 gautamUpdateIOOIMC is locking normally againOver the last 24 hours, the IMC autolocker
was able to keep the MC locked ~60% of the
time. This is not particularly good, but
 IMCdutycycle.png 
  12824   Mon Feb 13 13:34:44 2017 gautamUpdateIMCIMC length loop - bad SMA cable replacedI was a little confused why the In1 Gain
had to be as high as +10dB - before the changes
to the RF chain, we were using +27dB, and
 noisy_PMC_REFL.png 
  12822   Sun Feb 12 01:16:57 2017 gautamUpdateIMCIMC length loop - summary of changes29.5 MHz RF Modulation Source


 DemodBoardOrthogonality.pdfIMC_PDH.pdfTEK00001.PNGIMC_OLTF.pdfFSS_gain_comparison.pdf 
  12823   Mon Feb 13 11:55:14 2017 ranaUpdateIMCIMC length loop - summary of changesI would think that we want to fix
the I/Q orthog inside the demod board by
trimming the splitter. Mixing
  
  12899   Wed Mar 22 00:33:00 2017 gautamUpdateIMCIMC length offset nulling[valera, gautam]

Motivation: see this
elog
 offsetInvestigation.pdfoffset_summing_amp.pdf 
  13139   Mon Jul 24 19:57:54 2017 gautamUpdateCDSIMC locked, Autolocker re-enabledNow that all the front end models are running,
I re-aligned the IMC, locked it manually,
and then tweaked the alignment some more.
  
  16673   Tue Feb 15 19:40:02 2022 KojiUpdateGeneralIMC lockingIMC
is locking now. There was
nothing wrong: just a careful alignment +
  
ELOG V3.1.3-