40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 1 of 348  Not logged in ELOG logo
IDdown Date Author Type Category Subject Text Attachments
  17532   Thu Mar 30 16:45:09 2023 PacoSummaryLSCPRMI gain estimates and expected flashing at BHD and POP portsHere are our best estimates for the optic
transmission (power) coefficients.

  
  17531   Thu Mar 30 09:51:41 2023 PacoUpdateALSXALS / YALS power normalized and noise spectraAfter the XAUX - XARM lock was recovered
the C1:ALS-TRX_GAIN was set from 0.002 to
0.0006 to normalize the green transmission
 Screenshot_2023-03-30_10-07-34_ALS_OOL.png 
  17530   Wed Mar 29 19:19:41 2023 KojiUpdateALSX end green now indefinitely lockingStable
lock of the X End green laser was recovered.

- The biggest issue
 6x 
  17529   Wed Mar 29 17:00:23 2023 AnchalUpdateIOOMC Length feedback is present but not visible in MEDMI confirmed that MC Length feedback path
to MC2 position is present and has been turned
off in recent history. Feedback filter module
 MC2_LSC.png20230329_MC_L_Feedback_test.pdf 
  17528   Wed Mar 29 16:36:04 2023 PacoSummaryBHD"On why BH55 senses the LO phase, a finesse adventure of loss and residual DARM offsets"I repeated the calculations but with FPMI
(last
case was all MICH). The qualitative behavior
 FPMI_LOphase_sensors_loss.pdfFPMI_LOphase_sensors_dcrefl.pdfFPMI_LOphase_sensors_darmoffset.pdf 
  17527   Wed Mar 29 15:59:01 2023 AnchalUpdateIOOc1ioo model updated to add sensing to optic angle matricesI've updated c1ioo model with adding
WFS sensor to optic angle matrix and output
filter module option. The output filter modules
 WFSSensToOptAngMatrices.png 
  17526   Tue Mar 28 10:58:03 2023 ranaSummaryBHD"On why BH55 senses the LO phase, a finesse adventure of loss and residual DARM offsets"but what about including the DC reflectivity
imbalance of the arms? there would be another
BH55 term from that field maybe.
  
  17525   Mon Mar 27 20:28:57 2023 PacoSummaryBHD"On why BH55 senses the LO phase, a finesse adventure of loss and residual DARM offsets"Yuta pointed out that the BH55 signal was
weirdly never going to zero, so I actually
tuned the demod angle and made sure I was
 MICH_BHD_darmoffset.gif 
  17524   Sun Mar 26 19:13:48 2023 yutaSummaryLSCPRMI sensing matrix and RF demodulation phase tuningthat is really a lot of high precision
for the REFL_11 demod phase...

for this kind of measurement, I
  
  17523   Fri Mar 24 15:05:41 2023 yutaSummaryLSCPRMI sensing matrix and RF demodulation phase tuningPRMI sensing matrix was measured under
PRMI locked with REFL55_I and Q.
MICH actuator is 0.5*ITMX-0.5*ITMY
  
  17522   Fri Mar 24 12:54:51 2023 yutaSummaryLSCActuator calibration of PRM using PRYPRM actuator was calibrated using PRY by
comparing the actuation ratio between ITMY.
It was measured to be
 PRMActuatorTF.pngPRMActuatorRatio.png 
  17521   Thu Mar 23 19:15:39 2023 yutaSummaryLSCPRMI locked using REFL55[Paco, Yuta]

We
locked PRMI in sideband using REFL55_I and
 Screenshot_2023-03-23_15-58-25_PRY_OLTF.pngScreenshot_2023-03-23_18-48-25_PRMIlocking.pngScreenshot_2023-03-23_18-41-25_PRCL_PRMI.pngScreenshot_2023-03-23_18-40-55_MICH_PRMI.pngScreenshot_2023-03-23_18-44-12_PRMISB.png 
  17520   Thu Mar 23 17:47:53 2023 PacoUpdateNoiseBudgetLO phase noise budget (BH55_Q)I drafted a calibrated LO Phase noise budget
using diaggui whose template is saved under
/opt/rtcds/caltech/c1/Git/40m/measurements/BHD/LO_PHASE_cal_nb.xml
 lophase_cal_nb_20230322.pngPXL_20230323_202125206.jpgPXL_20230323_194150923.jpg 
  17519   Thu Mar 23 16:21:10 2023 ranaUpdateIMCBeam offset calculation for MC1,2,3 from dither resultsI have changed the MC SUS output matrices
by a few % for some A2L decoupling - if it
causes trouble, please feel free to revert.
 TuninMC2OutMat-A2L-beaucoup.pngIMC-A2Lnomore_cawcaw.png 
  17518   Thu Mar 23 14:20:29 2023 KojiSummaryBHD"On why BH55 senses the LO phase, a finesse adventure of loss and residual DARM offsets"This is interesting. With the FPMI, the
DARM phase shift is enhanced by the cavity.
Therefore, I suppose the effect on the BH55
  
  17517   Wed Mar 22 18:38:54 2023 PacoSummaryBHD"On why BH55 senses the LO phase, a finesse adventure of loss and residual DARM offsets"[Paco, Yehonathan]

I took over the finesse calculations
Yehonathan had set up for BHD. The notebook
 LOphase_sensors.pdfLOphase_sensors_loss.pdfLOphase_sensors_darmoffset.pdf 
  17516   Wed Mar 22 15:51:44 2023 AlexUpdateIMCBeam offset calculation for MC1,2,3 from dither resultsI have organized the resulting data from
running dither lines on MC1,2,3. The data
has been collected from diaggui as shown
 22032023_Dither_lines_demod_MC1_21-12.pdf 
  17515   Tue Mar 21 18:41:12 2023 AlexUpdateIMCDither Lines set on MC1, MC2, MC3 for the nightWith Anchal's help, I have setup dither
lines for Rana on MC1,2,3 that will be running
overnight. The oscilations were set on MC1,2,3,
 21032023_Dither_lines_plot 
  17514   Mon Mar 20 20:27:30 2023 yutaUpdateBHDLO phase noise contribution in MICH BHD[Paco, Yuta]

MICH was locked with balanced homodyne
readout with LO phase locked using BH55_Q
 MICH_Sensitivity_20230320.pdfMICH_Sensitivity_20230320_BH55Contribution.pdfMICH_Sensitivity_20230320_BH44Contribution.pdf 
  17513   Fri Mar 17 17:27:58 2023 Alex, TomohiroUpdateIMCArm Cavity Noise injection with WFS1/2 PIT and YAW Tomohiro and I performed some tests under
Rana's guidance to find cross corelations
between WFS1 and WFS2 output signals in both
 8x 
  17512   Thu Mar 16 13:31:25 2023 TomohiroUpdateIMCDiagonalizing YAW output matrix using a different method Purpose


To adjust the components
of the WFS2 column in the YAW output
 step_response_YAW_160323.pdfMar16_Dfactor.pdf 
  17511   Tue Mar 14 18:44:39 2023 yutaUpdateBHDLO phase noise measurements in ITMX single bounce, MICH and FPMI[Anchal, Yuta]

We have measured LO phase noise in
 BH555_BH44_LO_PHase_Control_Comparison.pdf 
  17510   Tue Mar 14 15:46:06 2023 TomohiroUpdateIMCDiagonalizing YAW output matrix using a different method Alex, Anchal, and I adjusted the number
of the MC2-TRANS column in the YAW output
matrix. We used the same method in 40m/17504 but
 step_response_YAW_140323.pdfMar14_Dfactor.pdf 
  17509   Tue Mar 14 13:59:11 2023 AnchalUpdateIMCIMC WFS aligned and offsets resetThe WFS loops were not maximizing the IMC
transmission. The transmission counts remained
stuck at around 12500 counts. The reflection
  
  17508   Tue Mar 14 11:38:44 2023 AnchalUpdateIMCTurned on 6:3lead FM7 on WFS1 and WFS2 YAW loopsI realized that for more phase margin,
rana
added 6:3lead filter on WFS PIT loops.
 Screenshot_2023-03-14_11-57-34.png 
  17507   Tue Mar 14 11:34:05 2023 AlexHowToComputer Scripts / ProgramsSummary Pages RestartIf the summary pages go down, it could
be from a break in the script or some small
error. The first remedy for fixing this can
  
  17506   Mon Mar 13 19:53:36 2023 yutaUpdateBHDFPMI BHD sensing matrix measurement with individual linesFPMI BHD sensing matrix was measured by
an updated method with updated RF demodulation
phases for REFL55 and AS55.
  
  17505   Mon Mar 13 15:37:13 2023 AlexUpdateIMCStep Response of newly diagonalizing YAW output matrixFrom the work that Anchal has completed
for diagnolizing the YAW ouput matrix, a
step response was taken of this new matrix
 step_response_YAW_130323.pdfWFS1_YAW_OLTF_NI.pdfWFS2_YAW_OLTF_NI.pdfMC2_YAW_OLTF_NI.pdfMar13_Dfactor.pdf 
  17504   Mon Mar 13 14:48:37 2023 AnchalUpdateIMCDiagonalizing YAW output matrix using a different methodI tried a different method today to see
if it works. Following are the steps:


Run WFS relief.
Turn
 WFS_YAW_OLTF_Measurements.pdf 
  17503   Fri Mar 10 16:42:16 2023 TomohiroUpdateIMCStep response test on MC1, MC2, and MC3 YAWSummary


We compared the new output
matrix with old one by the step
 step_response_YAW_S1_100323.pdfstep_response_YAW_S2_100323.pdfstep_response_YAW_S0_100323.pdfMar10_FlowDiagram.pdfMar10_Dfactor.pdf 
  17502   Thu Mar 9 19:20:44 2023 AnchalConfigurationCalibrationFPMI DARM calibration run set to happen at 1 amRunning this test again tonight. Will probably
run it every night now.

 
  
  17501   Thu Mar 9 14:22:24 2023 AlexUpdateComputer Scripts / ProgramsUpdate to toggleWFSoffsets.py for step response testingI have pushed changes made to the toggleWFSoffsets.py
script to the git.

This file may be found in: "/opt/rtcds/caltech/c1/Git/40m/scripts/MC/WFS/"
  
  17500   Thu Mar 9 10:29:15 2023 AlexUpdateIMCStep response test on MC1, MC2, and MC3 YAWTomohiro, Anchal and I completed the following
processs for acquiring a new Output Yaw matrix
for the "C1IOO_WFS_OUTMATRIX".
 step_response_080323.pdfScreenshot_2023-03-08_18-17-35.png 
  17499   Wed Mar 8 18:32:22 2023 AnchalConfigurationCalibrationFPMI DARM calibration run set to happen at 1 amOn rossa in tmux session name FPMI_DARM_Cal,
a script is running to take FPMI DARM calibration
data at 1:00 am on March 9th. Please do not
  
  17498   Wed Mar 8 09:58:24 2023 ranaUpdateIMCTransfer Function for IMC mirrors using appropriately filtered noisedoes Anyone understand why the broadband
noise injection is so bad around 1 Hz? we
do not see this issue with swept sine. noise
  
  17497   Wed Mar 8 09:17:21 2023 ranaUpdateIMCWFS noise ON/OFFWFS error signal spectra w loops ON (G=4)
and OFF.

Current output matrix also attached.
 mcwfs-output-matrix.png.pngwfsnoise_onoff_230308.pdf 
  17496   Tue Mar 7 23:32:54 2023 ranaUpdateIMCStep response test on WFS 1, 2 and MC2_TRANS YAWthis measured Yaw matrix seems very different
from the previous one. How can they really
both be stable?
  
  17495   Tue Mar 7 23:15:16 2023 ranaUpdateIOOIMC WFS summary pages updatedchanged some y-scale limits on the WFS
summary pages to zoom in better
  
  17494   Tue Mar 7 15:02:43 2023 TomohiroUpdateIMCTransfer Function for IMC mirrors using appropriately filtered noiseSummary


Alex, Anchal, and I adjusted
the every overall gain iin P/Y of WFS1,
 WFS1_YAW_OLTF_NI.pngWFS2_YAW_OLTF_NI.pngMC2_YAW_OLTF_NI.png 
  17493   Mon Mar 6 13:03:37 2023 TomohiroUpdateIMCStep response test on WFS 1, 2 and MC2_TRANS YAWSummary


We do the step responce
test on WFS 1, 2 and MC2_TRANS
 step_response_060323.pdf 
  17492   Sat Mar 4 18:57:18 2023 PacoConfigurationCalibrationFPMI DARM calibration run Locked FPMI, measured DARM and CARM OLTFs,
locked YAUX and measured the analog loop
TF at the cal line frequencies. Turned the
  
  17491   Fri Mar 3 18:47:13 2023 PacoSummaryBHDLO phase POS noise coupling - II tried some LO PHASE noise coupling measurements
today. With MICH locked using AS55_Q, I control
the LO phase using the single RF (BH55_Q)
 lophasenoise_bh55Qcontrol.pngbhnoisecoupling_excscreenshot.pngbh55q_noisecoupling.pngbh44q_noisecoupling.png 
  17490   Fri Mar 3 16:52:57 2023 ranaUpdateIMCTransfer Function for IMC mirrors using appropriately filtered noisethat is great

I think we would like to set the
WFS1 P/Y UGFs to be ~2-3 Hz, and the MC_TRANS
  
  17489   Thu Mar 2 18:37:05 2023 TomohiroUpdateIMCTransfer Function for IMC mirrors using appropriately filtered noiseSummary


Alex, Anchal, and I measure
the open-loop transfer function for
 NoiseFilter_TF.pngTF-MeasureExample.pngWFS1_YAW_OLTF_NI.pngWFS2_YAW_OLTF_NI.png 
  17488   Thu Mar 2 10:54:25 2023 PacoUpdateSUSLO1 dewhiteningWe added the DB9 short connectors to all
coil drivers in the BHD suspensions and updated
FM9-FM10 for LO1, LO2, AS1, AS4, SR2, PR2
 uncalibrated_lo_phase_errctrl_ADW.png 
  17487   Wed Mar 1 19:18:18 2023 PacoUpdateSUSLO1 dewhitening[Paco, Anchal]

Today we invested some time in
the DW filters for LO1 supension. We discovered
 uncalibrated_lo_phase_errctrl.png 
  17486   Wed Mar 1 17:13:38 2023 AlexUpdateIMCTransfer Function for IMC mirrors using sine sweepThe following work has been done by Tomohiro,
Anchal and I:

To acquire the transfer functions
 WFS1_PIT_OLTF.pdfWFS2_PIT_OLTF.pdfMC2_TRANS_PIT_OLTF.pdf 
  17485   Wed Mar 1 10:16:31 2023 TomohiroUpdateIMCAngular actuation calibration for IMC mirrors using AC sine waveAlex, Anchal, and I did the following experiment to
obtain calibration constants by oscillating
IMC mirrors.
  
  17484   Sun Feb 26 00:13:55 2023 AlexConfigurationASCIOO MC PIT/YAW gain changeThe following changes were made to the
WFS MASTER IMC Pitch and Yaw gains:

Gain values for the pitch and yaw
  
  17483   Fri Feb 24 15:21:39 2023 JCUpdateGeneralLarge Optical Table Movement SolidworksI sketched up the first encounter we will
have when moving the optical table out. I'm
assuming the table has already been turned
 Capture.PNGCapture1.PNG 
ELOG V3.1.3-