ID |
Date |
Author |
Type |
Category |
Subject |
8871
|
Thu Jul 18 15:55:31 2013 |
Jenne | Update | LSC | PRMI+Y arm ALS Sensing Matrices |
Last night, I took sensing matrix data at various different offsets for the Yarm. The sensing matrices I measured were of the PRMI, while the Yarm was (a) Held off resonance, (b) Held at ~50% peak power, and (c) Held on resonance.
The dither lines were clear in the MICH and PRCL spectrum, so I think I'm driving hard enough, but something else seems funny, since clearly the REFL165 I and Q signals were not completely overlapping last night. If they were, we wouldn't have been able to lock the PRMI using REFL 165 I&Q.
Anyhow, here's the data that was taken. Data folder is ...../scipts/LSC/SensingMatrix/SensMatData/
Yarm off resonance, SensMat_PRMI_1000cts_580Hz_2013-07-18_012848.dat

Yarm at ~50% resonance, SensMat_PRMI_1000cts_580Hz_2013-07-18_013937.dat

Yarm on resonance, SensMat_PRMI_1000cts_580Hz_2013-07-18_013619.dat

|
8870
|
Thu Jul 18 15:34:15 2013 |
Alex Cole | Update | Electronics | PD Frequency Response Update |
[Eric, Alex]
Our RF Switch arrived today, and we mounted it in rack 1Y1 (1st attachment).
We connect our input fiber and all of our output fibers to our 1x16 optical splitter (2nd attachment). Note that the 75 meter fiber we are using for the splitter's input is in a very temporary position (3rd attachment - it's the spool).
We successfully turned our laser on and tested the optical splitter by measuring output power at each fiber using our Thorlabs PM20 power meter. Data was taken with the laser running at 67.5 mA and 24 degrees Celsius:
Detector name Power
REF DET |
192 µW |
AS55 |
146 µW |
REFL55 |
180 µW |
REFL11 |
172 µW |
MCREFL |
133 µW |
REFL33 |
146 µW |
REFL165 |
180 µW |
POP22/POP110 |
182 µW |
POP55 |
193 µW |
POX11 |
123 µW |
|
Attachment 1: photo_3_(1).JPG
|
|
Attachment 2: photo_1_(4).JPG
|
|
Attachment 3: photo_2_(4).JPG
|
|
8869
|
Thu Jul 18 10:50:54 2013 |
Lisa | Update | LSC | PRMI+Y arm ALS success! |
Quote: |
[Koji, Jenne, Manasa, Annalisa, Rana, Nic]
PRMI locked using 3f signals and Y arm brought to resonance using ALS 
|
Fantastico! :-) |
8868
|
Thu Jul 18 10:47:21 2013 |
Jamie | Update | LSC | PRMI+Y arm ALS success! |
AWESOME! You guys rock. |
8867
|
Thu Jul 18 02:21:41 2013 |
Koji | Update | LSC | PRMI+Y arm ALS success! |
[Koji, Jenne, Manasa, Annalisa, Rana, Nic]
PRMI locked using 3f signals and Y arm brought to resonance using ALS 
<<Procedure>>
Preparation:
- After we checked the functionarity of the Yarm ALS, both arms were locked with the IR, and aligned by ASS.
- Disengaged the LSC feedback. Approximately aligned the PRM.
- Recorded the current alignment biases. Turned off all of the oplevs.
- Went into the lab, aligned all of the oplevs on the QPDs (except for the SRM).
- Check the locking of the PRMI.
- Once it is locked, go into the lab again and align the POP QPD.
- Check everything of the PRMI LSC/ASC works.
- Misalign PRM by 0.2
- Lock the arm again. Run ASS again.
- Miaslign ETMX.
ALS:
- Lock the Xarm with green. Adjust the beat freq between 30-50MHz.
- Reset Phase Tracker history.
- Check if there is any offset for the ALS. If there is, adjust it to zero.
- Stabilize the arm with the ALS. We should check the sign of the servo before it is cranked up to the nominal.
- Confirm if the offset FM has LPF (30mHz LPF).
- Run excastep for the ALS offset until we find the TEM00 resonance of the IR
- Record the offset at the resonance.
- Step back by 5 count (=100kHz)
PRMI+ALS:
- Started from the offset of -5.
- Aligned the PRM and the PRMI was locked by REFL165I(x0.8)nadQ(x0.2).
- PRM ASC engaged
- Moved the offset to -4 by ezcastep C1:ALS-OFFSETTER2_OFFSET +0.01,100 -s 0.1
- Moved to -3, -2, -1.5, -1. During the sweep PRCL/MICH gain was tweaked so that the gain is reduced.
Nominal locking gain was PRCL x+2.5/MICH -30 . During the sweep they were +2.2 / -12
PRCL FM2/4/5 ON, Later FM3/6 turned on and no problem.
- Moved to -0.9, .... , and finally to 0.
NEXT STEP
- Automation of the PRMI+one arm
- PRMI locking with BS/PRM
- Better sensing matrix
- PRMI+two arms
- Use of the DC signals form the transmission monitors. (High power /low power transmon).
|
Attachment 1: Screenshot-Untitled_Window1.png
|
|
Attachment 2: PRMI_Yarm.pdf
|
|
8866
|
Thu Jul 18 01:10:00 2013 |
kiwamu | Update | Green Locking | ALS Y performance with the new whitening filter |
Awesome !

|
8865
|
Wed Jul 17 22:51:50 2013 |
Koji | Update | Green Locking | ALS Y performance with the new whitening filter |
[Manasa Koji]
Summary:
The new whitening filters improved the out-of-loop ALS stability of the Y arm down to 300Hz (20pm_rms in displacement).
- After modifying the whitening filters, the out-of-loop stability of the arms were tested with the IR PDH signals.
- The X arm showed non-stationarity and it made the ALS servo frequenctly fell out of lock.
- For now we decided to use the Y arm for the PRMI+one arm trial.
- The performance of the ALS was tested with several measurements. (attachment 1)
Cyan: Stability of the beatnote frequency with the MC and the arm freely running. The RMS of the day was ~6MHz.
Blue: Sensing limit of the beat box was tested by giving a signal from Marconi. The same amplitude as the X arm beat was given as the test signal.
This yielded the DC output of ~1200 counts.
Green: Out-of-loop estimation of the beatbox performance. This beat note stability was measured by controlling the arm with the IR PDH signal.
Assuming the PDH signal has better SNR than the beat signal, this gives us the out-of-loop estimation of the stability below 150Hz, which is the
unity gain frequency of the ALS loop.
Above 150Hz the loop does not force this noise to the suspension. Just the noise is injected via a residual control gain (<1).
Black: In-loop evaluation of the ALS loop. This becomes the left over noise for the true stability of the arm (for the IR beam).
Red: The arm was brought to the IR resonance using the ALS offset. The out-of-loop stability was evaluated by the IR PDH signal.
This indeed agreed with the evaluation with the other out-of-loop evaluation above (Green) below 150Hz.
Attachment 2 shows the time series data to show how the arm is brought to the resonance.
1 count of the offset corresponds to ~20kHz. So the arm started from 200kHz away from the resonance
and brought to the middle of the resonance.
(Manasa downloaded the 2k sampled data so that we can use this for presentations.) |
Attachment 1: ALS_Y_130717.pdf
|
|
Attachment 2: ALS_Y2_StripTool.png
|
|
8864
|
Wed Jul 17 22:49:37 2013 |
Koji | Update | Green Locking | ALS Y whitening filter change |
[Koji Annalisa]
We did the same mod of the beatbox for the Y arm too. See
http://nodus.ligo.caltech.edu:8080/40m/8855 |
8863
|
Wed Jul 17 16:15:42 2013 |
Alex Cole | Configuration | Electronics | AS Table Additions |
[Eric, Alex]
We decided that the POY Table would be a better home for our REF DET (Newport 1611 FC-AC) than the AS Table. We moved the PD to the POY Table (1st attachment) and routed a fiber from our 1x16 Optical Splitter in the OMC_North rack to the POY Table. REF DET's power supply is now located under the POY table (2nd attachment). We left the fiber described in the previous post on the AS Table.
Afterwards, we hooked a fiber up to our laser module to test it (3rd attachment). The laser was not being distributed, just going to one fiber with a power meter at its end. Everything turns out, but we realized we need to read the power supply's manual before continuing.
|
Attachment 1: photo_1_(3).JPG
|
|
Attachment 2: photo_2_(3).JPG
|
|
Attachment 3: photo_3.JPG
|
|
8862
|
Wed Jul 17 11:13:36 2013 |
Alex Cole | Configuration | Electronics | AS Table Additions |
[Eric, Alex]
For the RFPD frequency response project, we routed the fiber that will connect our REF DET (on the AS table) to our 1x16 optical splitter (in the OMC_North rack), as pictured. (The new fiber is the main one in the picture, which ends at the right edge near REF DET) Note that we secured the fiber to the table in two places to ensure the fiber would remain immobile and out of other optical paths already in place.
At 2:00 we plan to run fiber from our laser module (in rack 1Y1) to our 1x16 optical splitter (in the OMC_North rack) and measure the power output at one of the splitter's output ports. We plan to keep the output power limited to less than 0.5 mW per optical splitter output. |
Attachment 1: photo_(1).JPG
|
|
8861
|
Tue Jul 16 19:16:12 2013 |
rana | Update | DAQ | NDS2 Status |
I have modified the settings on the router that connects our Martian network to the outside world so that one can access the NDS2 server running on megatron:31200.
To get at the data you point your data getting client (Matlab, ligoDV, DTT, etc.) at our router and the megatron port will be forwarded to you:
131.215.115.189:31200
is what you should point to. Now, it should be possible to run DetChar jobs (e.g. our 40m Summary pages) from the outside on some remote server. You can also grab 40m data on your laptop directly by using matlab or python NDS software. |
8860
|
Tue Jul 16 18:20:25 2013 |
Jenne | Update | CDS | Proto-ASC implemented in ASS model |
The proto-ASC now includes triggering. I have updated the hacky temp ASC screen to show the DoF triggering. I have to go, but when I get back, I'll also expose the filter module triggering. So, for now we may still need the up/down scripts, but at least the ASC will turn itself off if there is a lockloss. |
8859
|
Tue Jul 16 17:02:41 2013 |
Alex Cole | Configuration | Electronics | AS Table Additions |
[Eric, Alex]
We added our reference photodetector (Newport 1611, REF DET) to the southern edge of the AS table, as pictured. The detector's power supply is located under the southwest corner of the table, as pictured. We have connected the detector to its power supply, and will connect the detector's fiber input and RF output tomorrow.
EDIT: this is about the RFPD frequency response setup... |
Attachment 1: photo_1_(1).JPG
|
|
Attachment 2: photo_2_(2).JPG
|
|
8858
|
Tue Jul 16 15:22:27 2013 |
manasa | Update | CDS | Front ends back up |
c1sus, c1ioo, c1iscex and c1iscey were down. Why? I was trying to lock the arm and I found that around this time, several computers stopped working mysteriously. Who was working near the computer racks at this time???
I did an ssh into each of these machines and rebooted them sudo shutdown -r now
But then I forgot / neglected/ didn't know to bring back some of the SLOW Controls computers because I am new here and these computers are OLD. Then Rana told me to bring them back and then I ignored him to my great regret. As it turns out he is very wise indeed as the legends say.
So after awhile I did Burtgooey restore of c1susaux (one of the OLD & SLOW ones) from 03:07 this morning. This brought back the IMC pointing and it locked right away as Rana foretold.
Then, I again ignored his wise and very precious advice much to my future regret and the dismay of us all and the detriment of the scientific enterprise overall.
Later however, I was forced to return to the burtgooey / SLOW controls adventure. But what to restore? Where are these procedures? If only we had some kind of electronics record keeping system or software. Sort of like a book. Made of electronics. Where we could LOG things....
But then, again, Rana came to my rescue by pointing out this wonderful ELOG thing. Huzzah! We all danced around in happiness at this awesome discovery!!
But wait, there was more....not only do we have an ELOG. But we also have a thing called WIKI. It has been copied from the 40m and developed into a thing called Wikipedia for the public domain. Apparently a company called Google is also thinking about copying the ELOG's 'find' button.
When we went to the Wiki, we found a "Computer Restart Procedures" place which was full of all kinds of wonderous advice, but unfortunately none of it helped me in my SLOW Controls quest.
Then I went to the /cvs/cds/caltech/target/ area and started to (one by one) inspect all of the targets to see if they were alive. And then I burtgooey'd some of them (c1susaux) ?? And then I thought that I should update our 'Computer Restart Procedures' wiki page and so I am going to do so right now ??
And then I wrote this elog.
|
8857
|
Tue Jul 16 14:51:09 2013 |
gautam | Configuration | endtable upgrade | AI Board-D000186-Modified notches |
I tried shifting the notch frequencies on the D000186-revision D board given to me by Koji. The existing notches were at ~16 kHz and ~32 kHz. I shifted these to notches at ~64 kHz and ~128 kHz by effecting the following changes (see schematic for component numbering) on Channel 8 of the board-I decided to check things out on one channel before implementing changes en masse:
- R6 and R7 replaced with 511 ohm smts
- R8 replaced with 255 ohm smt
- R14 and R15 replaced with 549 ohm smts
- R16 replaced with 274 ohm smt
=> New notches should be at 66.3 kHz and 131.7 kHz.
I then measured the frequency response of the modified channel using the SR785, and compared it to the response I had measured before switching out the resistors. The SR785 only goes up to 102 kHz, so I cannot verify the 128 kHz notch at this point. The position of the 64 kHz notch looks alright though. I think I will go ahead and switch out the remaining resistors in the evening.
Note 1: These plots are just raw data from the SR785, I have not tried to do any sort of fitting to poles and zeros. I will do this at some point.
Note 2: All these smts were taken from Downs. Todd helped me locate the non-standard value resistors. I also got a plastic 25-pin D-sub backshells (the spares are in the rack), with which I have fashioned the required custom ribbon cables (40 pin IDC to 25 pin D-sub with twisted ribbon wire, and a short, 10pin IDC to 10pin IDC with straight ribbon wire).

|
8856
|
Tue Jul 16 13:48:26 2013 |
Steve | Update | PEM | cranes cleaned |
Keven and Steve,
The 3 cranes tested and wiped off as preparation for upcoming vent. |
8855
|
Tue Jul 16 10:16:23 2013 |
Koji | Update | | Beatbox XARM whitening modified |
The X arm whitening filters of the beatbox were modified.
Now we have about 10 times better floor level above 100Hz and ~3 better at 1Hz.
- The previous whitening was zero@1Hz, pole@10Hz, and the DC gain of the unity.
When the Marconi signal (~30MHz -25dBm) was given to the beatbox (via ZFL-1000LN),
the DC output of the beatbox was only 140mV (lame). This corresponded to 220 counts in
the CDS. (BTW the signals were calibrated by giving frequency deviation of 1kHz is applied at 125Hz.)
- If you compare the analog measurement of the beatbox output and what we see in the I phase signal,
you can see that we were completely dominated by the ADC noise (attachment 2, blue and red).
- The new whitening is zero@5.2Hz, pole@159Hz, and the DC gain of 10.
- This improved the sensing noise by a factor of ten above 100Hz.
- We are stil llimited by the digitizing noise between 3Hz to 100Hz.
We need steeper whitening like 2nd order from 1Hz to 100Hz. (and probably at DC too).
Now the DC amplitude is about 1.4V (and 2200 counts in the CDS).
So, it is interesting to see how the sensing limit changes by increasing
the overall gain by a factor of 3, and have (zeros@1Hz & poles@10Hz)^2.
This can be implemented on a proto-daughter board.
- By the way, the performance below 2Hz is now better than the analog one with the previous whitening.
This improvement might have come from the replacement of the thick film resistors by thin-film resistors.
(See the circuit diagram)
About the nominal power of the beatbox input.
- Marconi (-20dBm 30MHz) was directly connected to the beatbox. The RF output of -15dBm was observed at the delayline output.
- According to the beatbox schematic, the mixer LO and RF inputs were expected to be -9dBm and -19dBm.
- The nominal mixer LO level is supposed to be 7dBm. Therefore the nominal beatbox input should be -4dBm.
- Assuming 23dB gain of the preamp, the PD output is expected to be -27dBm.
- When the PD out is -27dBm, the RF mon is expected to be -5dBm. This is the level of the RF power expected to be seen in the control room.
- The output of the beatbox was measured as the function of the input to the preamp (before the beatbox input).
With the nominal gain, we should have observed amplitude of ~170. And it is now 1700 because of the whitening modification.
|
Attachment 1: Beatbox_mod.pdf
|
|
Attachment 2: ALS_whitening.pdf
|
|
Attachment 3: Beatbox_input_dependence.pdf
|
|
8854
|
Tue Jul 16 01:17:21 2013 |
Jenne | Update | ASC | POP QPD calibration attempt |
[Rana, Jenne]
I took POP QPD calibration data with a new method, on Rana's suggestion. I locked the PRMI, and engaged the ASC servo, and then used awggui (x8) to put dither lines on all of the PRMI-relevant optic's ASCPIT and ASCYAW excitation points. I then took the transfer function of the suspensions' oplev signals (which are already calibrated into microradians) to the POP_QPD signals (which are in counts). This way, we know what shaking of any optic does to the axis translation as seen by the POP QPD. We can also infer (from BS or PRM motion for PR3, and ITMX motion for PR2) what the folding mirrors do to the axis translation. Note that we'll have to do a bit of matrix math to go from, say, PRM tilt effect to PR3 tilt effect on the axis motion.
The data is saved in /users/jenne/PRCL/July152013_POP_TFs.xml . There is also a .txt file with the same name, in the same folder, listing the frequencies used by the awg.
I'll analyze and meditate tomorrow, when my brain is not so sleepy. |
8853
|
Mon Jul 15 17:59:31 2013 |
gautam | Configuration | endtable upgrade | DAC at 1Y4- Power Spectrum -6.4kHz bandwidth |
Quote: |
Those 'peaks' for the oscillations seem ridiculously broad. I think you should look again, really quickly, with smaller bandwidth at, say, the 2kHz oscillation, to make sure it looks reasonable.
|
I did just this, and it looks okay to me:

|
8852
|
Mon Jul 15 17:20:43 2013 |
Jenne | Configuration | endtable upgrade | DAC at 1Y4- Power Spectrum -with the right units |
Those 'peaks' for the oscillations seem ridiculously broad. I think you should look again, really quickly, with smaller bandwidth at, say, the 2kHz oscillation, to make sure it looks reasonable. |
8851
|
Mon Jul 15 17:16:59 2013 |
Jenne | Update | ASC | POP QPD calibration attempt |
I tried to retake POP QPD calibration data again today. The MC was mostly fine, but whenever the PRMI unlocked, both ITM watchdogs would trip. I'm not sure what was causing this, but the ITM alignment wasn't perfect after this kind of event, so I felt like I was continuously locking and realigning the arms to get the alignment back. Then, after turning on the ASC and tweaking up the PRM alignment for maximum POP110I signal, I had to recenter the QPD, so none of my previously taken data was useful. Frustrating. Also, I had recentered the PRMI-relevant oplevs, but I had these weird locklosses even with nicely centered oplevs.
I have given up for the daytime, and will come back to it if there's a spot in the evening when arm measurements aren't going on.
Here is the data from last week, and the data from today. The micrometer readings have been calibrated into mm, and I have fit a line to the linear-looking region. Obviously, for the Pitch calibration, I definitely need to take more data.



|
8850
|
Mon Jul 15 16:51:37 2013 |
Alex | Configuration | | Planned AS Table addition |
[Eric, Alex]
We are planning to add our reference PD to the southern third of the AS Table as pictured in the attachment. The power supply will go under the table. |
Attachment 1: AS_Table_Ref_PD_Addition.pdf
|
|
8849
|
Mon Jul 15 16:44:46 2013 |
Alex | Update | OMC | OMC North Safety |
[Eric Alex]
We are planning on testing our laser module soon, so we have added aluminum foil and a safety announcement to the door of OMC North. The safety announcement is as pictured in the attachment. |
Attachment 1: photo_2_(1).JPG
|
|
8848
|
Mon Jul 15 15:54:20 2013 |
gautam | Configuration | endtable upgrade | DAC at 1Y4- Power Spectrum -with the right units |
Quote: |
We need the unit of the voltage power spectrum density to be V/sqrt(Hz).
Otherwise we don't understand anything / any number from the plot.
|
I redid the measurement with the appropriate units set on the SR785. Power spectral density plots for no output (top), 500Hz, 1000 counts amplitude sine wave (middle) and 2000Hz, 1000 counts amplitude (bottom) are attached, with the right unit on the Y-axis.



|
8847
|
Mon Jul 15 14:12:15 2013 |
Steve | Update | VAC | RGA scan at day 144 |
Pumpdown 75, vacuum normal condition at day 144
|
Attachment 1: pd75mRGA144d.png
|
|
Attachment 2: pd75m144d.png
|
|
8846
|
Mon Jul 15 13:51:17 2013 |
Koji | Configuration | endtable upgrade | DAC at 1Y4-Max Output and Power Spectrum |
We need the unit of the voltage power spectrum density to be V/sqrt(Hz).
Otherwise we don't understand anything / any number from the plot. |
8845
|
Mon Jul 15 11:51:18 2013 |
gautam | Configuration | endtable upgrade | DAC at 1Y4-Max Output and Power Spectrum |
Summary:
I measured the maximum output of the DAC at 1Y4 as well as its power spectrum. The results are as follows (plots below):
- Maximum amplitude of differential output: + 10V.
- Power spectrum has a peak at 64 kHz.
Therefore, the gain of the high-voltage amplification stage on the PZT driver boards do not need to be changed again, as the required output range of 0-100V from the DAC board was realised when the input voltage ranged from -10V to +10 V w.r.t ground. The AI board converts the differential input to a single ended output as required by the driver board.
I will now change some resistors/capacitors on the AI board such that the position of the notches can be moved from 16k and 32k to 64k and 128k.
Procedure:
Max. amplitude measurement
My previous measurement of the maximum output amplitude of the DAC was flawed as I made the measurement using a single channel of the oscilloscope, which meant that the negative pin of the DAC channel under test was driven to ground. I redid the measurement to avoid this problem. The set up this time was as follows:
- Positive pin of DAC connected to channel 1 of oscilloscope using break out cable and mini-grabber probe
- Negative pin of DAC connected to channel 2 of oscilloscope
- Grounds of channels 1 and 2 connected (I just hooked the mini-grabbers together)
- Measurement mode on oscilloscope set to channel 1 - channel2
- Used excitation points set up earlier to output a 3 Hz sine wave with amplitude of 32000 counts from channel 9 of the DAC.
The trace on the oscilloscope is shown below;

So with reference to ground, the DAC is capable of supplying voltages in the range [-10V 10V]. This next image shows all three traces: positive and negative pins of DAC w.r.t ground, and the difference between the two.

Power spectrum measurement
I used the SR785 to make the measurement. The set up was as follows:
- Positive pin of DAC to A-input of SR560
- Negative pin of DAC to B-input of SR560
- A-B output to Channel 1 input A of the SR785
- SR785 configured to power spectrum measurement
Initially, I output no signal to the DAC, and obtained the following power spectrum. The peak at 65.554 kHz is marked.

I then re-did the measurement with a 200 Hz (left) and 2000 Hz(right), 1000 counts amplitude (I had to change the Ch1 input range on the SR785 from -18dBm to -6dBm) sine wave from channel 9 of the DAC, and obtained the following. The peaks at ~64 kHz are marked.

Now that this peak has been verified, I will work on switching out the appropriate resistors/capacitors on the AI board to move the notches from 16k and 32k to 64k and 128k. |
8844
|
Sun Jul 14 18:19:00 2013 |
Annalisa | Update | Green Locking | Arm cavity scan |
Yesterday evening Nic and me were in the lab. The Mode Cleaner was unlocked, but after many attempt we could fix it and we did many scans of the Y arm cavity.
Today I was not able to keep the MC locked. Koji helped me remotely, and eventually the MC locked back, but after half an hour of measurements I had to stop.
I made some more scan of the Y arm though. I also tried to do the same for the X arm, but the MC unlocked before the measurement was finished. I'll try to come back in the night. |
8843
|
Sun Jul 14 17:47:28 2013 |
Koji | Update | IOO | MC WFS maintenance |
Annalisa notified me that the MC autolocker could not keep the MC locked.
I found the initial alignment was not good and the MC was too much excited when the WFS kicked in.
There might have been the WFS offset issue due to the miscentering of the spots on the WFS diodes.
I used the usual procedure of the maintenance and it looked OK if I followed the switching procedure the mc autolocker suppoed to do.
http://nodus.ligo.caltech.edu:8080/40m/7452
I still could not get the autolocker running smoothly. I opened mcup script and compared what was the difference
between my manual sequence and what the script did. The only difference was the lines related to MCL.
It was still turning on the filter module. I checked the MCL path and found that the gain was not zero but 1.0.
So now the MCL gain is set to zero. This solved all the remaining issue. |
8842
|
Sat Jul 13 03:27:20 2013 |
Annalisa | Update | Green Locking | Y arm caity scan |
I started doing a scan of the Y arm cavity with IR with ALS enabled.
ALS servo tuning:
The servo tuning procedure is basically the same as described in elog 8831.
This time I had a stronger beat note(-14 dBm instead of -24 dBm of the last measurement) thanks to a better alignment.
Plot1 shows the Power spectrum of the BEATY_PHASE_OUT. The RMS is smaller by a factor of 2 (400Hz), corresponding to a residual motion of about 25 pm.
Offset setting avity scan
In order to give an offset linearly growing in time, I used the ezcastep script instead of giving the offset in OFFSETTER2. If the ramp time is long enough, it is not necessary to enable the 30mHz filter.
To span 2 FSR, I started from an offset of 450 and I gave a maximum value of 1600 with a delay of 0.2s between two consecutive steps.
Cavity scan
I did a first scan with the cavity well aligned, basically to know the position of the 00 peaks and choose the best offset range (Plot2)
Then I misaligned the TT2, first in PITCH and yhen in YAW, in order to enhance the HOMs. (Plot3 and Plot4)
More investigation and measurements needed.
|
Attachment 1: PowerSpectrum0712
|
Attachment 2: ScanCavityAligned.pdf
|
|
Attachment 3: ScanCavityMisPitch.pdf
|
|
Attachment 4: ScanCavityMisYaw.pdf
|
|
8841
|
Fri Jul 12 23:13:32 2013 |
manasa | Update | Green Locking | ALS sensor noise |
[Annalisa, Koji, Manasa]
In order to improve the ALS stability we went ahead to check if we are limited by the sensor noise of ALS.
What we did:
RF signals similar to the beatnote were given at the RF inputs of the beatbox.
The frequency of the RF signal was set such that I_OUT was zero (zero-crossing point of the beatbox).
We measured the noise spectrum of the phase tracker output.
Measurements:
Plot 1: X ALS noise spectrum
Plot 2: Y ALS noise spectrum
Discussion:
The X arm ALS noise is not limited by the sensor noise...which means we shoudl come up with clever ideas to hunt for other noise sources.
But this does not seem to be the case for the Y arm ALS. The Y arm part of the beatbox is noisy for frequencies < 100Hz.
After looking into the details and comparing the X and Y arm parts of beatbox, it looks that amplitude of the beat signal seem to affect the Y arm ALS noise significantly and changes the noise spectrum.
To do:
Investigate the effect/limitations of amplitude of the beatnote on the X arm and Y arm beatbox.
|
Attachment 1: X_ALS_0712.pdf
|
|
Attachment 2: Y_ALS_0712.pdf
|
|
8840
|
Fri Jul 12 21:23:42 2013 |
Jenne | Update | ASC | POP QPD calibration attempt |
These are the data, one plot for when the vertical QPD position was changed, and one for when the horizontal (yaw) QPD position was changed.
The micrometer is in inches, so 1 unit is 0.1 inches, I believe.
Clearly, I need to redo the measurement and take more data in the linear region. |
Attachment 1: ChangeVertMicrometer_July2013.png
|
|
Attachment 2: ChangeSideMicrometer_July2013.png
|
|
8839
|
Fri Jul 12 18:30:20 2013 |
Charles | Update | ISS | RMS Noise from PMC Transmission |
Quote: |
It would be better to measure the power spectrum density of the fluctuation.
The RMS does not tell enough information how the servo should be.
In deed, the power spctrum density gives you how much the RMS is in the entire or a specific frequency range.
|
I wanted the RMS noise simply to establish a very rough estimate of thresholds on RMS detectors that will be part of my device. If you refer to elog 8830, I explain it there. Essentially, when the ISS is first engaged, only one of the 2 or 3 filter stages will be active. Internal RMS threshold detection serves to create a logic input to switch subsequent filters to their 'on' stage. |
8838
|
Fri Jul 12 13:15:43 2013 |
Koji | Update | ISS | RMS Noise from PMC Transmission |
It would be better to measure the power spectrum density of the fluctuation.
The RMS does not tell enough information how the servo should be.
In deed, the power spctrum density gives you how much the RMS is in the entire or a specific frequency range. |
8837
|
Fri Jul 12 12:51:16 2013 |
manasa | Update | LSC | PRMI + ALS automation |
Quote: |
We talked about how it should be automated.
We'll gradually offload the switching works on scripts.
|
Here is the list of automations that we need to work on for less hectic PRMI+ALS trials.
1. Enable/Disable ASC when PRMI is locked/unlocked.
2. Smooth transfer from REFL33/AS55 to REFL165 when PRMI is locked.
3. Change actuation from the ITMs to BS and PRM after PRMI lock.
4. Enable ALS.
5. IR resonance scan using ALS. |
8836
|
Fri Jul 12 12:51:13 2013 |
Charles | Update | ISS | RMS Noise from PMC Transmission |
I went out on the floor to look at the transmitted signal from the PMC to get a rough idea of the noise of the unstabilized laser. There was already a scope hooked up so I just used the measurement features to find the following:
Signal average = 875 mV. Peak-to-Peak noise = 45 mV
Assuming the noise can be approximated as Gaussian noise, the heuristic for converting to RMS noise of the signal is RMS = Peak-to-Peak / 8 (or Peak-to-Peak / 6, I've used both...)
-> RMS Noise ~ 6.5 mV
When designing my filtering stages and RMS detection/triggering, I'll use relative RMS, i.e. 6 mV / 875 mV = 0.007, as a measure of unstabilized laser noise. |
8835
|
Fri Jul 12 12:30:47 2013 |
manasa | Update | General | Halogen illumination cables disconnected |
Quote: |
Alex and Steve,
Old halogen chamber illuminator cabling disconnected and potenciometer board removed at 1Y1 in order to give room for pd calibration fibre set up.
|
During the process, they had also removed the power cable to the ITMY camera. Steve and I fixed this...so the camera is back. |
8834
|
Fri Jul 12 09:00:10 2013 |
Steve | Update | General | Halogen illumination cables disconnected |
Alex and Steve,
Old halogen chamber illuminator cabling disconnected and potenciometer board removed at 1Y1 in order to give room for pd calibration fibre set up. |
Attachment 1: 1Y1oldilluminatersDisconnected.jpg
|
|
8833
|
Fri Jul 12 00:12:41 2013 |
Koji | Update | LSC | PRMI + Y arm trial |
[Koji, Manasa, Annalisa]
I made several trials to scan the arm on the IR TEM00 resonance while the PRMI was held with REFL165I&Q.
It was so hectic to keep multiple systems running correctly. We talked about how it should be automated.
We'll gradually offload the switching works on scripts.
In a good alignment condition, when I swept on the resonance, everytime the PRMI lost the lock. It reacquired
once the arm passed the resonance.
Lately I got difficulty to acquire lock of the PRMI while the arm is waiting at its off resonance.
If I change the ALS offset I got a stable lock in a certain offset, and did not get in another offset
so there could be something systematic. (The arm was in between the carrier resonance and the next sideband (55MHz) resonance).
-----
Procedure
[Preparation]
- Run LSCoffset script.
- Misalign PRM. Lock and align the arms with ASS.
- Go into the tables. Align the oplevs for ETMX/Y, ITMX/Y, and BS. (Very important for alignment stability)
- Align PRMI and lock PRMI. Unlock once.
- Go into the BS/PRM table. Align the oplev for PRM.
[ALS]
- Misalign PRM by -0.2
- Find the beat note at around 50MHz by changing the Yarm SLOW control. Today the PSL SLOW was ~0.24, and the Yarm SLOW was -10981.
- Reset Phase Tracker History (Important)
- Engage Yarm ALS with FM5. Tested the sign of the servo by giving 0.01 or -0.01. In my case, the negative number worked fine.
Gradually increase the gain up to -10. Turn on FM2/3/6/7/10.
- Use Filter module "C1ALS-OFFSETTER2" to give the ALS sweep. I used FM1 (30mHz LPF). Change the offset while looking at the IR TRY and POY11 error signal.
- Once the resonance is found, shift the beat note by giving +10 or -10 offset.
[PRMI]
- While the arm is kept off resonance, align PRM.
- Lock PRMI with REFL33I and AS55Q. Turn on PRM ASC.
- Once the stable lock is obtained, switch the input signals to REFL165I&Q. I used REF33I x1.0->REFL165I x0.8 and AS55Q x1.0 -> REFL165Q x0.5
[PRMI + one arm]
- Revert the ALS offset by 10 to bring the arm on the resonance the see what happens.
|
8832
|
Thu Jul 11 23:50:57 2013 |
gautam | Configuration | | PZT Driver Board-changes made |
Summary:
Continued with tests on the PZT driver board. I made a few changes to replace defective components and also to modify the gain of the HV amplifier stage. I believe the board has been verified to be satisfactory, and is now ready for a piezo to be connected, tested and calibrated.
Changes made:
- I tested the board with the full 100V bias voltage today, working my way up from 30V in steps of about 20V and verifying the output at each stage.
- In order to deliver 100V to the board, it was necessary to change the maximum current limit on the KEPCO supply, which is set at default at ~1.6 mA. The KEPCO power supply placed near rack 1X2 (which I believe was used to power a piezo driver board) is labelled 150V, 12 mA, though I found that the board only drew 7mA of current when the power supply output 100V. I have set the limit to 10 mA for the time being.
- The potentiometer in the third stage (R44 in the schematic) was faulty so I replaced it with another 100K potentiometer, which was verified to work satisfactorily.
- We expect the DAC output to supply a voltage to the input of the PZT driver board in the range -10V to 10V. Today, I verified this by using my temporary break-out cable. I hooked this up to the DAC at 1Y4 and output a 3 Hz sine wave with amplitude of 32000 counts (the maximum) on channel 9. The output as observed on an oscilloscope (image attached) was a 10Vpp sinusoid, confirming the above hypothesis. As mentioned in my previous elog, the gain of the high-voltage amplifier stage is ~15, which would mean the output would saturate if the input were to be >6V. I have changed the gain of all 4 stages (M1-pitch, M1-yaw, M2-pitch and M2-yaw) to ~4.85 by swapping the 158k resistors (R43, R44, R69 and R70 in the schematic) for 51k resistors.
- It was necessary to change the value of the biasing potentiometers after the change in gain so that 0 input voltage once again provided 50V at the output, as required by the PZTs for there to be no tilt. This was done and verified. This biasing voltage now is ~10.4V in all four stages.
- Having adjusted the gain, I tested the circuit over the expected full range of the input voltage from the DAC (from -10V to 10V) from the DS345 function generator (0.05Hz sinusoid). I monitored the output using a multimeter, as the monitor channels were peaking at ~7V, which was above the limit for the oscilloscope I was using. It was verified for all four channels that the output was between 0 V and 100 V (the safe range quoted in the datasheet for the tip-tilts, for this range of input voltages. So I think we are ready to connect a PZT to the board and conduct further tests, and calibrate the PZT.
Pending Issues:
- Koji pointed out that there has to be an anti-imaging filter stage between the DAC output and the filter stage, which I had not considered till this point.Another subtle point is that the DAC output is differential while the driver boards have a single-ended input, which means we effectively lose half the range of the PZTs.
- A suitable candidate is the D000186-rev D. Some information about the present state of this board is detailed in this elog. This board also solves the problem of the differential vs single input as the input to the AI board is differential while the output is single-ended. Koji has given me one of the boards he had collected.
- Some changes will have to be made to this version of the board in order to make it compatible with the existing DAC. I will first have to measure the power spectrum of the DAC output to verify that the AI boards need notches at 64k and 128k. The existing notches are at 16k and 32k, and once the DAC power spectrum has been verified, I hope to affect the necessary changes by switching out the appropriate capacitors on the existing board.
- The AI board is an extra element which I have now added to an updated wiring diagram, attached.
Revised Wiring Diagram:

DAC Max. Output Trace on Oscilloscope

|
8831
|
Thu Jul 11 14:38:38 2013 |
Annalisa | Update | Green Locking | Y arm cavity scan |
Yesterday I did a cavity scan with IR while holding the Yarm with green.
ALS servo tuning:
The gain of the loop is set such that BEATY_FINE_Q_ERR x GAIN = 120k. This is a kind of "empirical low" in order to have the UGF around 1kHz.
Start with FM5 [1000:1] enabled, determine the sign of the gain increasing it in small steps and making sure that the mirror doesn't get a kick. Then gradually raise it while looking at the BEATY_PHASE_OUT power spectrum.
Enable FM7 [RG16.5], FM6 [RG3.2], FM3 [1:5], FM2[0:1], FM10 [40:7].
Plot 1 shows the power spectrum of BEATY_PHASE_OUT (calibrated in Hz).
- blue curve - ALS disabled
- green curve - in loop measurement, ALS enabled and servo tuned as described above
- grey curve - RMS of the in loop measurement
- red curve - out of loop measurement (arm locked with IR)
- pink curve - RMS of the out of loop measurement
Offset setting and cavity scan
The C1ALS_OFFSETTER2 was used to set an offset for ALS scan.
- LPF30m enabled
- Ramp time set to 150s
- Offset set to 1500 (approximately 3 FSR in this interval)
Many scans have been done to find the optimal offset conditions, I only attached one (Plot 2).
I also misaligned the END mirror in pitch to enhance the HOMs peaks, but it turned out that it was not enough, because I didn't see a very big difference between the "aligned" and the "slightly misaligned" measurements (Plot 3).
NEXT STEPS
Increase the cavity misalignment both in pitch and in yaw and repeat the measurement.
|
Attachment 1: IRlocked_res_mot_0710.pdf
|
|
Attachment 2: ArmScanN5.png
|
|
Attachment 3: CavityScanETMYmis
|
8830
|
Thu Jul 11 13:52:51 2013 |
Charles | Update | ISS | RMS threshold detection and triggering |
There are essentially two major portions of the ISS I am designing. One system has the voltage reference, differential amplifier and filtering servo (schematic attached) while the other has a comparator circuit and a triggering mechanism. The first system amplifies an error signal obtained from the PD output and the voltage reference, which is then fed back through the AOM. I've done a lot of work designing/prototyping this first half and now I'm starting to design the second half.
The second system's main purpose is to maintain loop stability as the ISS is engaged. Let's assume a user has decided they want noise suppression. They would first close the ISS feedback loop and an error signal would pass through three unity-gain buffers, providing minimal noise reduction. The user can then send a signal to theTRIGGER 1 port to switch the first stage from its unity-gain position to its filtering position and reduce the intensity noise further. This signal will most likely be digital in origin. Alternatively, when the user first closes the ISS loop, the first stage can already be in its filtering position rather than necessitating two commands.
A test channel (not drawn in the included schematic) will monitor the RMS level of the incoming signal from the PD. This noisy AC signal will first be amplified and then passed through an RMS-to-DC converter. The resulting DC signal is used as a part of the triggering mechanism for later stages. Once the first stage has been switched manually, and the DC signal corresponding to RMS noise of the PD output drops below a certain threshold, stages 2 and 3 will be internally triggered with a short delay between them. Toward being able to detect this threshold, I have designed a simple comparator circuit with an LT1016. The circuit has a fairly low-level output when the input voltage is larger than the threshold (about 1.6 V for my simple prototype), but when the input passes below the threshold, the comparator puts out almost 4 V, a number limited by the supply voltage. The schematic is shown below.

The component V2 and the various voltage dividers serve to establish the reference/threshold voltage. Note that although the LT1016 is not powered in the schematic, it requires ±5 V (a max of 7 V). The above circuit was also prototyped on a breadboard and I characterized it with an oscilloscope. Using a CFG253, I made a low frequency (~0.3 Hz) triangle wave with an amplitude and DC offset such that it oscillates between 0 and 5 V. This was applied to the IN node in the above schematic. The input waveform and the circuit's response (voltage at the OUT node) are shown below. As expected, R2 serves to establish hysteresis. The comparator switches to 'high' output until the input drops below 1.6 V, and then it doesn't switch back to the 'low' output until the input goes up to ~3.4 V.

This behavior is ideal for our application as we can detect when the DC signal from the RMS-to-DC converter drops below a certain level (i.e. the first stage that has been activated does some amount of filtering to lower RMS noise), and then we can trigger subsequent filter stages off of the comparators high-level output.
This circuit could easily be used to drive the MAX333a switches shown in the first schematic attached. I believe the low-level output is not sufficient to switch the MAX333a although the ~4 V high-level output is quite sufficient. Regardless, these exact values (thresholds, outputs etc) will be determined after I have a better idea of the RMS noise of the laser without any intensity stabilization as well as a solid understanding of how the AD8436 RMS-to-DC converter works. This was simply a proof of concept for lower threshold detection using basic Schmitt trigger topology. |
Attachment 1: 40mServo_v1.pdf
|
|
8829
|
Thu Jul 11 12:00:50 2013 |
Alex | Update | | Planned rack additions |
[Eric, Alex]
We mounted our Laser Module and Laser Power Source in rack 1y1. We plan to add our RF Switch and Transformer Module to the rack, as pictured. (Note: drawn-in boxes in picture are approximately to scale.) Note that the panel of knobs which the gray boxes overlap is obsolete and will soon be removed. |
Attachment 1: Annotated_Rack_1y1_-_update.pdf
|
|
8828
|
Thu Jul 11 09:24:03 2013 |
Steve | Update | General | there should be nothing left on optable tops |
There are 4 oscilloscopes left on the AP optical table top.... It's only 25 lbs... Do not leave anything on the optical table tops! |
8827
|
Thu Jul 11 09:15:10 2013 |
Steve | Update | endtable upgrade | ETMY optable grounded |
ETMY optical table top was grounded to the ETMY chamber through 1 Mohms this morning. I also strain releifed relieved a few cables that were pulling on components directly. |
8826
|
Thu Jul 11 07:34:42 2013 |
manasa | Update | LSC | Yarm held nicely on IR resonance with ALS, PRMI+arm attempt |
Quote: |
We knew that the Yarm was well aligned, since our IR resonance was > 0.98, but it had been a while since we had aligned the X arm.
|
The X arm was locked with TRX>0.98 earlier last night while I was measuring the out of loop noise of the phase tracker. |
8825
|
Thu Jul 11 03:14:19 2013 |
Jenne | Update | LSC | Yarm held nicely on IR resonance with ALS, PRMI+arm attempt |
[Annalisa, Jenne, Nic]
After having troubles with the Xarm earlier (maybe Manasa can write/say something about this? Something about perhaps seeing the phase tracker jump, and cause it to lose lock?), we moved on to the Y arm.
Annalisa locked the Yarm green, and closed the ALS loop. I believe that earlier today, she tuned the gain such that we don't start getting gain peaking at a few hundred Hz. We would like to get a script going, so that it's not so labor intensive to reclose the ALS loop after an MC lockloss....but that's a daytime task.
We then found the IR resonance, using only the Yarm ALS system. After Manasa's work yesterday, the Yarm was very stable while locked with the ALS. We took a power spectrum of POY11_I_ERR, which I have calibrated using the number in elog 6834 of 1.4e12 cts/m, or 7.14e-13 m/ct. See the figure below.
After that, we changed the offsetter2 offset such that the arm was off resonance, but not so far off that we crossed any significant resonances (in particular, we wanted to not go as far as the 55MHz resonance).
Then, I tried to lock the PRMI for a while, but the alignment wasn't very good. We knew that the Yarm was well aligned, since our IR resonance was > 0.98, but it had been a while since we had aligned the X arm. I tweaked the ITMX position to make the Michelson dark, and then tried acquiring PRMI lock. At first, I tried with REFL165 I and Q, but with the non-ideal alignment and the offset in the 165 diode (LSC offsets was not run this evening), I wasn't catching any locks. I then switched to AS55Q and REFL33I, but wasn't able to catch lock there either.
The MC lost lock, which made us lose the ALS loop, but the ALS had been locked for more than 30 minutes, at least. I tried locking the PRMI with the current alignment (after having misaligned ETMY), but was only able to get lock stretches of 1 second at maximum.
We are calling it a great success for the night, since we have confirmed that, at least for the Yarm, Manasa's beatbox work has improved things. Also, we have a pretty solid plan for trying the PRMI+arm tomorrow, even though it didn't work out tonight. |
Attachment 1: Yarm_onIRresonance_noPRMIyet_POYcalibrated.pdf
|
|
8824
|
Thu Jul 11 00:30:27 2013 |
manasa | Update | Green Locking | X arm ALS post-beatbox makeover |
I ran a series of diagnostics on the X arm ALS to look at how the beatbox behaves after the makeover.
Diagnostic tests run:
1. X arm ALS in-loop spectrum
2. X arm ALS out-of loop spectrum
3. X ALS scan of the X arm cavity
The noise suppression looks better after the makeover at the lower frequencies. To suppress the noise at high frequencies, we would have to add more whitening filters. |
Attachment 1: XALS_inloop.pdf
|
|
Attachment 2: XALS_scan.pdf
|
|
Attachment 3: ALS_outloop.pdf
|
|
8823
|
Wed Jul 10 22:41:06 2013 |
gautam | Configuration | endtable upgrade | PZT Driver Board |
I did the following with the PZT Driver Board:
-
With an expansion card attached to the driver board, I used an Agilent E3620A power supply to verify that the 15V and 24V supplies were reaching the intended ICs. It turns out that the +24 V supply was only meant to power some sort of on-board high voltage supply which provided the 100V bias for the PZTs and the MJE15030s. This device does not exist on the board I am using, jumper wires have been hooked up to an SMA connector on the front panel that directly provides 100V from the KEPCO high voltage supply to the appropriate points on the circuit.
-
All the AD797s as well as the LT1125CS ICs on the board were receiving the required +15V.
The next step was to check the board with the high-voltage power supply connected.
-
The output from the power supply is drawn from the rear output terminal strip of the power supply via pins TB1-2 (-OUT) and TB1-7 (+OUT). I used a length of RG58 coaxial cable from the lab and crimped a BNC connector on one end, and stripped the other to attach it to the above pins.
-
There are several options that can be configured for the power supply. I have left it at the factory default: Local sensing (i.e. operating the power supply using the keypad on the front of it as opposed to remotely), grounding network connected (the outputs of the power supply are floating), slow mode, output isolated from ground.
- I was unsure of whether the grounding network configuration or the 'positive output, negative terminal grounded' configuration was more appropriate. Koji confirmed that the former was to be used so as to avoid ground loops. When installed eventually, the eurocrate will provide the ground for the entire system.
- I then verified the output of the HV power supply using a multimeter from 2V up to 150V.
- I then connected the high voltage supply to the PZT driver board with a BNC-SMA adaptor, set, for a start, to output 30V. Ensured that the appropriate points on the circuit were supplied with 30V.
I then hooked up a function generator in order to simulate a control signal from the DAC. The signal was applied to pin 2 of the jumpers marked JP1 through JP4 on the schematic, one at a time. The signal applied was a 0.2 Vpp, 0.1 Hz sine wave.
- The output voltage was monitored both using a DMM at the SMB output terminals, and at the monitor channels using an oscilloscope. The outputs at both these points were as expected.
- There are 4 potentiometers on the board, which need to be tuned such that the control output to the piezos are 50V when the input signal is zero (as this corresponds to no tilt). The gain of the amplifier stage (highlighted in the attached figure) right now is ~15, and I was using 30V in place of 100V, so an input signal of 2V would result in the output saturating. This part of the circuit will have to be tuned once again after applying the full 100V bias voltage.
- Koji suggested decreasing the gain of the amplifier stage by switching out resistor R43 (and corresponding resistor in the other 3 stages on the board) after checking the output range of the DAC so that possibility of unwanted saturation is minimised. I need to check this and will change the resistors after confirming the DAC output range.
- The potentiometers will have to be tuned after the gain has been adjusted, and with 100V from the high-voltage DC power supply.
To Do:
- Switch out resistors
- Tune potentiometers with 100V from the HV supply
- Verify that the output from the board after all the tuning lies in the range 0-100V for all possible input voltages from the DAC.
- Once the output voltage range has been verified, the next step would be to connect a PZT to the board output, affix a mirror to the tip/tilt, and perform some sort of calibration for the PZT.

|
8822
|
Wed Jul 10 14:49:00 2013 |
Steve | Update | Green Locking | more fiber protective tubing layed |
Quote: |
Craig, Gautam and Steve,
Single mode fiber 50m long is layed out into cable tray that is attached to the beam tube of the Y arm.
It goes from ETMY to PSL enclosure. It is protected at both ends with " clear- nylon slit corrugated loom tubing " 1.5" ID
The fiber is not protected between 1Y1 and 1Y4
|
Installed 0.5" ID 10 ft long protective tubing at the PSL end of the ETMY fiber this morning. Here I had to cable tie a bunch of cables at the east side of the PSL enclosure.
They were hanging off the table blocking space were the sliding doors move.
At the ETMX end of the X-arm fiber received the same protective tubing. |
Attachment 1: fibreETMXprotectedendOnly.jpg
|
|