Update:
Upon investigation, the other methods besides process_data() take almost no time at all to run, by comparison. The process_data() method takes roughly 2521 seconds to run using Multiprocessing with eight threads. After its execution, the rest of the program only takes 120 seconds to run. So, since I still need to restructure the code, I won't bother adding multiprocessing to these other methods yet, since it won't significantly improve speed (and any improvements might not be compatible with how I restructure the code). For now, the code is just about as efficient as it can be (in terms of multiprocessing). Further improvements may or may not be gained when the code is restructured. |
8217
|
Mon Mar 4 09:55:33 2013 |
rana | Update | LSC | LSC whitening triggering started |
How about posting a logic flow diagram? Is the idea to trigger only on the power signals to determine the lock state? Is the hysteresis going to be done in the same way as the main filter bank triggers? |
8216
|
Mon Mar 4 09:51:26 2013 |
Steve | Update | ASS | IP-ANG is still not real |
IP-ANG is coming out of ETMY without clipping. The beam is very high on the pick off mirror at the end table but it is still missing the qpd .
|
Attachment 1: IP-ANG.png
|
|
8215
|
Sun Mar 3 22:16:46 2013 |
Jenne | Update | LSC | LSC whitening triggering started |
[Jenne, Annalisa]
We have started working on writing the c-code to parse the LSC input matrix, to see which PD is used for what degree of freedom, and to output a trigger for the PD. The code is in ..../isc/c1/src, and there is a little block in the LSC code to the left of the triggering stuff. Right now, the output of the c-code just goes to some temporary EPICS channels, so that we can see if things are working before we actually implement it. At this time, there is no change to how the LSC model runs.
I can't figure out a bug in my c-code though. Right now it's all commented out, so that the LSC model would start, but if I try to sum all of the elements in an array, the model compiles fine, but it won't start running. I'm going to ask Jamie about it tomorrow. I have a less-tidy backup plan if we can't get this figured out.
If I have time on the IFO to check that this works tomorrow, I expect another few hours of work (2? 3?), and then we'll have whitening filter triggering. |
8214
|
Sat Mar 2 20:09:12 2013 |
yuta | Update | RF System | phase tracker: DAQ noise limited |
[Koji, Yuta]
We found that our phase tracker noise is currently limited by the noise introduced in DAQ.
We confirmed that the frequency noise was improved from 2 Hz/rtHz to 0.4 Hz/rtHz by increasing the gain of the whitening filter.
The whitening filters should definitely be refined.
What we did:
1. Put constant frequency RF input to the beatbox from Marconi and measured noise spectrum of the beatbox output(BEATX I) after the whitening filter with a spectrum analyzer. Noise floor level was ~0.2 Hz/rtHz at carrier frequency range of 15-100 MHz. Calibration factor of the beatbox output was ~380 mV/MHz.
2. Measured noise spectrum of C1:ALS-BEATX_FINE_I_OUTPUT(figure below). The noise floor didn't change when there was RF input of 100 MHz from Marconi(blue) and DAQ input was terminated (green). Also, C1:ALS-BEATX_FINE_I_IN1(which is before unwhitening filter) showed a flat spectrum. These show our spectrum is limited by DAQ noise, which is introduced after the whitening filter.
3. We increased the gain of whitening filter by x20 to show frequency noise performance can be improved by better whitening filter(red). But we can not use this setup as the other quadrature will be saturated by a too much gain at DC. Thus we need to carefully consider the signal level and the gain distribution of the whitening filters.

Next:
- Better whitening filters. The current one consists of zero 1 Hz and pole 10 Hz with DC gain of 5 using SR560.
- Better beatbox. We can increase the RF input power to the mixer and unify the preamplifier and the whitening filter in the box. |
8213
|
Sat Mar 2 14:52:02 2013 |
rana | Update | LSC | stable lock of PRMI |
Whereas the sensing matrix coefficients for ITMX/ITMY in REFL_I indicate an actuation imbalance, the disparity in the ITMX/ITMY to AS_Q elements does not. However, they do indicate why there is a PRM to AS_Q coupling at all.
I would recommend setting up the triggering so that the REFL & AS whitening is turned on AFTER lock acquisition and using a frequency of ~100-300 Hz for the sensing matrix measurement to fix these issues. |
8212
|
Sat Mar 2 05:53:15 2013 |
yuta | Update | LSC | stable lock of PRMI |
I tuned alignment, gains and filters to achieve stable lock of PRMI.
It now locks quite stably with UGF of ~100 Hz. Measured power recycling gain at maximum is ~ 25.
Locking details:
== PRMI carrier ==
MICH: AS55_Q_ERR, AS55_PHASE_R = -12 deg, MICH_GAIN = -1, feedback to ITMX(-1),ITMY(+1)
PRCL: REFL55_I_ERR, REFL55_PHASE_R = 70 deg, PRCL_GAIN = 0.3, feedback to PRM
MICH servo is always on. PRCL loop turns on by trigger using POP DC. Boost filters and resonant gains turn on by triggers using POP DC.
Gain normalization was not used.
Openloop transferfunctions:
MICH: UGF ~90 Hz, phase margin ~40 deg
PRCL: UGF ~100 Hz, phase margin ~50 deg (cf. Fitted gain was same as half-PRC: elog #8053)

Power recycling gain:
POP DC when unlocked is 6, when locked is 2200-2500, and when dark is 0. So, power recycling gain is ~ 22 to 25. Value without any loss in PRMI is 45 (elog #6947). Alignment was pretty critical to achieve this recycling gain and stable lock.
There was oscillation at 630 Hz when locked, which is similar to the one we saw in POX11 (elog #8203).
Youtube:
AS(top left), POP(top right), REFL(bottom left), and ETMYT(bottom right). ETMY was mis-aligned, but you can see the beam at ETMYT after PRMI was carrier locked.
MICH/PRCL coupling:
I measured "sensing matrix" of PRMI by tickling PRM/ITMs/BS at 8.5 Hz and measuring 8.5 Hz peak height of AS55_Q, REFL55_I spectra during PRMI lock (attached is an example measurement of PRM). Below table is the result. AS55_Q has ~5% of sensitivity to PRCL compared with MICH. Also, BS introduces REFL55_I signal considerably. And also, there seems to be an imbalance in actuation efficiency between ITMX and ITMY.
actuation AS55_Q_ERR REFL55_I_ERR
ITMX +11.4 +0.80
ITMY +33.0 +1.06
BS +50.8 +1.90
PRM - 0.7 +1.05
AS clipping:
AS was clipped inside the vaccuum the other day(elog #8198). So, I tried to avoid AS clipping by aligning BS this morning. But it turned out that avoiding AS clipping by BS makes ITMX beam centering worse. Maybe we should center the beam on Yarm first next week.
Next:
- calculate expected PRMI recycling gain with loss, PR2 filpped
- beam centering on the arms
- IPANG, IPPOS, Y green, X green
- PRMI g-factor measurement |
Attachment 3: PRMtoAS55REFL55.png
|
|
8211
|
Sat Mar 2 00:23:19 2013 |
rana | Summary | COC | Phase Maps measured of the ATF flat mirrors |
I took the two 'flat' 2" mirrors over to Downs and Garilynn showed me how to measure them with the old Wyko machine.
The files are now loaded onto our Dropbox folder - analysis in process. From eyeball, it seems as if the RoCs are in the neighborhood of ~5 km, with the local perturbations giving ~10-15 km of curvature depending upon position (few nm of sage over ~1 cm scales)
Koji's matlab code should be able to give somewhat more quantitative answers...
Ed: Here you are. "0966" looks good. It has RoC of ~4km. "0997" has a big structure at the middle. The bump is 10nmPV (KA)
|
Attachment 1: 0966_0997_phasemap.pdf
|
|
8210
|
Sat Mar 2 00:09:31 2013 |
rana | Update | LSC | Xarm oscillation stopped |
Don't use resonant gain - it can lead to a loop instability since it makes the loop have 3 UGFs.
Just use a elliptic bandstop filter at this harmonic frequency separately for each test mass. There are many detailed examples of this in elog entries from Rob and I over the past ~10 years. This bandstop should get clicked on automatically after lock acquisition. |
8209
|
Fri Mar 1 18:23:28 2013 |
Jamie | Update | Computer Scripts / Programs | updated version of "getdata" |
I updated the getdata script so that it can now handle downloading long stretches of data.
/opt/rtcds/caltech/c1/scripts/general/getdata
It now writes the data to disk incrementally while it's downloading from the server, so it doesn't fill up memory.
I also added a couple new options:
* --append allows for appending to existing data files
* --noplot suppresses plotting during download |
8208
|
Fri Mar 1 16:58:37 2013 |
yuta | Update | LSC | Xarm oscillation stopped |
POX11 oscillation at 630 Hz was stopped by installing 630 Hz resonant gain to LSC_XARM.
After few hours, oscillation stopped. So I removed the resonant gain.
Our guess is that 630 Hz peak is some violin mode or something, and it was excited somehow, and didn't stopped for very long time because of its high Q. It coupled into POY11 somehow (scattering, electronics, etc). |
Attachment 1: POX11_630Hz.png
|
|
8207
|
Fri Mar 1 16:37:45 2013 |
Brett | Update | SUS | Global Damping Update |
Brett and Kamal
The global damping testing for the week is now complete. The c1sus.mdl simulink diagram settled on the attached screenshot. The top level of c1sus.mdl is shown on the left zoomed in over the new global damping block. The right shows the inside of that block. Also attached in the second screenshot are two of the modal damping MEDM screens. The left shows the main overview screen, the right shows the global damping filters. The overview screen is called C1SUS_GLOBAL.adl and is found in ...medm/c1sus/master/.
We have measured transfer functions and power spectra that show that global damping, with just a moderate amount of tuning (30 minutes of work) reduces the OSEM damping noise seen by YARM_IN1 by a factor between 50 and 80. Log 8193 highlights the transfer function measurements. The power spectra directly measure the noise in the cavity. I am not putting that data here because I have to catch. I will process the data and post it here later.
Overall the global damping tests appear to have been successful, isolating (not removing) the test mass damping noise from the cavity by almost 2 orders of magnitude. Presumably even more isolation is possible with more tuning.
|
Attachment 1: GlobalDamp_Simulink.png
|
|
Attachment 2: GlobalDampScreens.png
|
|
8206
|
Fri Mar 1 14:50:36 2013 |
Steve | Update | VAC | pumpdown day 8 |
Atm1, RGA background scan with TP3 pumping at day 7
Atm2, IFO CC1 = 1.1e-5 Torr at day 8
Vacuum valve VM3 closed and VM2 opened, it switched the RGA to IFO scanning mode. CC4 = 3.5e-6 Torr
TP3 is pumping on the annuloses, their pressures are 1-3 mTorr
Vacuum condition reached the state of Vacuum Normal. The MEDM screen "Current State" channel does not work because we disconnected some valves after the VME swap CAOS
Note: TP1 Maglev performance on Atm2 CC4 = 4e-9 Torr when VM2 valve was open
|
Attachment 1: bgTP3d7.png
|
|
Attachment 2: RGAonIFO.png
|
|
8205
|
Fri Mar 1 08:19:40 2013 |
Steve | Update | ASS | drift |
Early morning drift in pitch. This plot is meaningless because there is no real light on IP-Ang
The beam is clipping on the pick off mirror at ETMY chamber. The beam is half beam size too high. Yaw is perfect
|
Attachment 1: drift.png
|
|
8204
|
Fri Mar 1 02:49:34 2013 |
Jenne | Update | ASS | Arm A2L measurement |
I haven't finished debugging the scripts so that the measurement is fully automatic, like the MC, but I did measure the arm spot positions just now.
These numbers aren't especially precise....I just picked numbers off of a StripTool plot, but they give us a good idea of how very far off we are. Also, I don't know yet which way the signs go...I have to think about that in terms of the direction I mis-balanced the coils. It's the same convention as the MC though. You can see in the attached quad camera image (quadrants match the corners of the table) that these numbers aren't unreasonable.
ETMY |
|
ETMX |
|
Pit |
4 mm |
Pit |
4 mm |
Yaw |
-1.5 mm |
Yaw |
6 mm |
ITMY |
|
ITMX |
|
Pit |
-3 mm |
Pit |
-3 mm |
Yaw |
4 mm |
Yaw |
-4 mm |

EDIT: It occurs to me now, a little later, that it had been at least half an hour since I last realigned the cavities, so some of this apparent miscentering is due to the input pointing drift. That doesn't account for all of it though. Even when the cavities have very high transmitted power, the spots are visibly miscentered. |
8203
|
Fri Mar 1 01:17:06 2013 |
Jenne | Update | LSC | Xarm oscillation |
There is an oscillation in the Xarm at 631Hz, which is not in the Yarm. There is a small peak in POY11_I at this frequency, but only when the Xarm is locked. If the Xarm unlocks, the peak disappears from POY. The peak is 3 orders of magnitude larger in POX than in POY, and 4 orders of magnitude larger than the POY noise when this peak is not present. In the plot, I have turned off the POY whitening, so that its situation is the same as POX (we still need to fix POX whitening switching). Dark noise (MC unlocked) is the same for both PDs.

|
8202
|
Thu Feb 28 14:51:43 2013 |
Jenne | Update | PEM | "Rock Monster" causing low frequency noise |
Manasa and I have been wondering why the low frequency seismic noise has been different in the last few days/weeks. I went over to visit the Rock Monster, a.k.a. the Earth Surface Dynamics Laboratory next door, and the grad student turned it up for me (increased water flow significantly) for a few minutes. Then I came back to look at the BLRMS, and you can see the low frequency increase a few minutes ago, when he turned it up on high. He said that they run it on low almost all the time, 9am-5pm ish, and on high for an hour or so at a time periodically during the day.

|
8201
|
Thu Feb 28 14:19:20 2013 |
Max Horton | Update | Summary Pages | Multiprocessing Implementation |
Okay, more memory would definitely be good. I don't think I have been using MEDM (which Jamie tells me is the controls interface) so making a cronjob would probably be a good idea. |
8200
|
Thu Feb 28 06:51:17 2013 |
yuta | Update | RF System | phase tracker: noise level |
I measured noise level of the phase tracker by inputting constant frequency RF signal from marconi.
Measured frequency noise was ~2 Hz/rtHz @ 100 Hz. It's not so good.
What I did:
1. Unplugged 11MHz marconi and put RF signal to the beatbox from this. Frequency and amplitude I put are 100 MHz and -3 dBm.
2. Measured spectra of phase tracker outputs, C1:ALS-BEATX_FINE_PHASE_OUT, C1:ALS-BEATY_FINE_PHASE_OUT.
3. Calibrated using the factor I measured (elog #8199).
4. Put marconi back to orignal settings.
Result:

Discussion:
- According to Schilt et al., this noise level is not so good.
- By changing the delay-line cable length or optimizing whitening filter etc., we can improve this.
|
8199
|
Thu Feb 28 05:54:54 2013 |
yuta | Update | RF System | phase tracker: calibration |
I swept the frequency of RF input to the beatbox to calibrate and check linearity range of phase tracker.
Calibration factors are;
C1:ALS-BEATX_FINE_PHASE_OUT 52.1643 +/- 0.0003 deg/MHz
C1:ALS-BEATY_FINE_PHASE_OUT 51.4788 +/- 0.0003 deg/MHz
There was systematic error to the linearity check, but at least, calibration factor changes less than 50 % in the frequency range of 10 MHz to more than 500 MHz.
What I did:
Used network analyzer(Aligent 4395A) to sweep the frequency RF input to the beatbox and getdata of phase tracker signal. I swept from 10 Hz to 500 MHz with 501 points in 50 sec. This sweep is slow enough considering we could lock the 40m arms (typical speed of a mirror is 1 um/s, so bandwidth of the phase tracker should be more than 1 um/sec / 40 m * 3e14 Hz = 75 MHz/s).
RF amplitude was set to be -3 dBm and splitted into BEATX and BEATY.
Result:
Plots for BEATX and BEATY are below;
 
Discussion:
- Considering delay line length is ~30m, expected calibration factor is;
2*pi*l/v = 2*pi * 30 m / (2e8 m/s) = 0.94 rad/MHz = 54 deg/MHz
so, this calibration is reasonable.
- Since frequency sweep of network analyzer is not continuous, phase tracker output is like steps with some ringdown. This makes some systematic error for checking linearity. I'm planning to do slower sweep or continuous sweep. Also, the phase tracker seems like he can exceed 500 MHz. |
8198
|
Thu Feb 28 03:41:31 2013 |
Koji | Update | LSC | PR gain ~ 25 from PRMI carrier lock |
VERY GOOD!
This is how the carrier lock PRMI should look like.
- There is more room to improve the differential ITM alignment to make the dark port more dark, then you will gain more PRG
- The AS spot is definitely clipped. |
8197
|
Thu Feb 28 03:25:27 2013 |
yuta | Update | LSC | PR gain ~ 25 from PRMI carrier lock |
[Manasa, Yuta]
We locked PRMI in carrier. Measured power recycling gain was ~25.
Plot:
Here's some plot of PRC intra-cavity powers and MICH,PRCL error signals. As you can see from POPDC, cavity buildup was about 400, which means power recycling gain was ~25. Power recyling gain is fluctuating up to ~45 during lock. We need some gain normalization or something.

Movie:
Here's 30 sec movie of AS, POP, REFL when acquiring PRMI carrier lock. Although there's oscillation when acquiring lock, beam spot motion is less and stable compared with the past(before flipping PR2).
Locking details:
== PRMI carrier ==
MICH: AS55_Q_ERR, AS55_PHASE_R = -12 deg, MICH_GAIN = -0.1, feedback to ITMX(-1),ITMY(+1)
PRCL: REFL55_I_ERR, REFL55_PHASE_R = 70 deg, PRCL_GAIN = 5, feedback to PRM
Next:
- Better filters and gains for stable lock
- Kakeru method to measure g-factor (see elog around #1434)
- OSA to measure g-factor |
8196
|
Thu Feb 28 02:43:49 2013 |
yuta | Update | LSC | some qualitative evidence of PRMI sideband lock |
[Manasa, Yuta]
Since we have setup POP22 PD now(elog #8192), we could confirm that sideband power builds up when PRMI is sideband locked.
Plot:
Here's some plot of PRC intra-cavity powers and MICH,PRCL error signals. As you can see from POP22, we locked at the peak of 11MHz sideband. There was oscillation at ~500 Hz, but we couldn't optimize the gain yet.

Movie:
Here's 30 sec movie of AS, POP, REFL when acquiring (and losing) PRMI sideband lock. It was pretty hard to take a movie because it locks pretty seldom (~1 lock / 10 min).
Locking details:
For MICH lock, we used ITMs instead of BS for reducing coupling between PRCL.
Also, AS55 phase rotation angle was coarsely optimized by minimizing MICH signal in I.
For PRCL lock, we used REFL55_I_ERR instead of REFL33_I_ERR. It had better PDH signal and we coarsely optimized phase rotation angle by minimizing PRCL PDH signal in Q.
== PRMI sideband ==
MICH: AS55_Q_ERR, AS55_PHASE_R = -12 deg, MICH_GAIN = -0.1, feedback to ITMX(-1),ITMY(+1)
PRCL: REFL55_I_ERR, REFL55_PHASE_R = 70 deg, PRCL_GAIN = -15, feedback to PRM
We set POP22_PHASE_R = -170 deg by minimizing Q.
Issues:
- We tried to use REFL55_Q_ERR to lock MICH, but couldn't. It looks like REFL error signals are bad.
- We tried to use POP22_I_ERR to trigger PRCL lock, but it didn't work. |
8195
|
Wed Feb 27 23:19:54 2013 |
rana | Update | Summary Pages | Multiprocessing Implementation |
At first I thought that this was goofy, but then I logged in and saw that Megatron only has 8GB of RAM. I guess that used to be cool in the old days, but now is tiny (my laptop has 8 GB of RAM). I'll see if someone around has some free RAM for a 4600; in the meantime, I've killed a MEDM that was running on there and using up a few hundred MB.
Run your ssh-MEDMs elsewhere or else I'll make a cronjob to kill them periodically. |
8194
|
Wed Feb 27 22:46:53 2013 |
Max Horton | Update | Summary Pages | Multiprocessing Implementation |
Overview: In order to make the code more maintainable, I need to factor it into different well-documented classes. To do this carefully and rigorously, I need to run tests every time I make changes to the code. The runtime of the code is currently quite high, so I will work on improving the runtime of the program before factoring it into classes. This will be more efficient (minimize testing time) and allow me to factor more quickly. So, my current goal is to improve runtime as much as possible.
Multiprocessing Implementation:
I invented a simple way to implement multiprocessing in the summary_pages.py file. Here is an example: in the code, there is a process_data() function, which is run 75 times and takes rather long to run. I created multiple processes to run these calls concurrently, as follows:
Original Code: (around line 7840)
for sec in datasections:
for run in run_opts:
run_opt = 'run_%s_time' % run
if hasattr(tabs[sec], run_opt) and getattr(tabs[sec], run_opt):
process_data(cp, ifo, start, end, tabs[sec],\
cache=datacache, segcache=segcache, run=run,\
veto_def_table=veto_table[run], plots=do['plots'],\
subplots=do['subplots'], html_only=do['html_only'])
#
# free data memory
#
keys = globvar.data.keys()
for ch in keys:
del globvar.data[ch]
The weakness in this code is that process_data() is called many times, and doesn't take advantage of megatron's multiple threads. I changed the code to:
Modified Code: (around line 7840)
import multiprocessing
if do['dataplot']:
... etc... (same as before)
if hasattr(tabs[sec], run_opt) and getattr(tabs[sec], run_opt):
# Create the process
p = multiprocessing.Process(target=process_data, args=(cp, ifo, start, end, tabs[sec], datacache, segcache, run, veto_table[run], do['plots'], do['subplots'], do['html_only']))
# Add the process to the list of processes
plist += [p]
Then, I run the process in groups of size "numconcur", as follows:
numconcur = 8
curlist = []
for i in range(len(plist)):
curlist += [plist[i]]
if (i % numconcur == (numconcur - 1)):
for item in curlist:
item.start()
for item in curlist:
item.join()
item.terminate()
keys = globvar.data.keys()
for ch in keys:
del globvar.data[ch]
curlist = []
The value of numconcur (which defines how many threads megatron will use concurrently to run the program) greatly effects the speed of the program! With numconcur = 8, the program runs in ~45% of the time of the original code! This is the optimal value -- megatron has 8 threads. Several other values were tested - numconcur = 4 and numconcur = 6 had almost the same performance as numconcur = 8, but numconcur = 1 (which is essentially the same as the unmodified code) has a much worse performance.
Improvement Cap:
Why does numcores = 4 have almost the same performance as numcores = 8? I monitored the available memory of megatron, and it is quickly consumed during these runs. I believe that once 4 or more cores are being used, the fact that the data can't all fit in megatron's memory (which was entirely filled during these trials) counteracts the usefulness of additional threads.
Summary of Improvements:
Original Runtime of all process_data() statements: (approximate): 8400 sec
Runtime with 8 processes (approximate): 3842 sec
This is about a 55% improvement for speed, in this particular sector (not in the overall performance of the entire program). It saves about 4600 seconds (~1.3 hours) per run of the program. Note that these values are approximate (since other processes are running on megatron during my tests. They might be inflated or deflated by some margin of error).
Next Time:
This same optimization method will be applied to all repetitive processes with reasonably large runtimes. |
8193
|
Wed Feb 27 22:28:53 2013 |
Brett | Update | SUS | Global Damping Update |
New excitation points were added after the global damping loops for more testing options. The updated c1sus.mdl model was re-committed to the svn. Two interesting simulink 'requirements' were found during this minor modification. First, excitation points must be placed on the top level of the diagram. If they are in a subsystem you will get compiling errors. Second, the excitation name must end in _EXC. It will compile OK if you don't do this, but the excitation points will not put out any excitations.
To do further investigation on the mysterious gain factor of 2.5 between the ETMY and ITMY POS damping loops, I measured TFs in the POS direction to the locked YARM signal for each. This provides an additional sensor, common to both, so we can see if the gain is coming from the actuation side or sensing side of the damping loops. The difference in these TFs is about
2.895
So it seems the majority of the damping gain difference is on the actuation side with some small difference on the sensing side. In order to allow for the later splitting of YARM LSC control between ITMY and ETMY (global damping and the cavity control must be along the same coordinate system), I placed this gain of 2.95 in ITMY_LSC.
To get a first measure of the relative performance of global damping to local damping I measured some TFs between the sensor signal inputs and YARM. So first, while the cavity was still locked with just ETMY, I measured a TF between C1:SUS-ITMY_SUSPOS_EXC and C1:LSC-YARM_IN1. Second, I split the cavity control evenly between the ETMY and ITMY by adjusting C1:LSC-OUTPUT_MTRX. I turned off the local damping and turned on the common DOF global damping (called CARM at this point despite being on just one arm). I then repeated the same TF but driving from C1:SUS-GLOBAL_CARMDAMP_EXC.
The resulting TFs are displayed in the attached figure. The blue curve is then the TF from local damping sensor noise to YARM. The green is global damping sensor noise to YARM. The suppression between local to global is in red. The global damping curve is about 50 to 100 times lower (better) than local damping. This can probably be improved with further tuning to account for remaining differences between the ITMY and ETMY.
Note, the damping loop used in the filter modules for all of these is zpk(0,[15 15],1), with a gain of 30. This purposely has little high frequency filtering so it is easier to see the influence on YARM. |
Attachment 1: DampNoise_to_YARM_fig_27Feb2013.png
|
|
8192
|
Wed Feb 27 20:50:41 2013 |
Manasa | Update | LSC | 22/110MHz path for POP |
[Yuta, Manasa]
Modified POP path.
1. Removed temporary POP DC and the BS 50 (elog)
2. Introduced a 95% BS after the POP steering mirrors (95% of the signal goes to PD10CF used for POP22 and 5% goes to POP camera)
3. Output of PD10CF goes to the LSC rack through POP110 heliax cable.
4. The PD output at the LSC rack goes through a DC block to separate DC from RF.

We could not find a power supply slot for the amplifiers on the LSC rack. We had to put a temporary power supply in contradiction to our 'no temporary power supply' policy.
|
8191
|
Wed Feb 27 20:10:43 2013 |
rana | Update | Locking | DRFPMI flashes |
If its true that there have been large flashes, then there indeed might be beer. But first I'd have to see a calibrated plot. And make sure that the flashes are not overamplified due to a whitening filter imbalance.
Is it the readout of a PD with no whitening/antiwhitening? IF so, its much easier to believe. |
8190
|
Wed Feb 27 19:27:29 2013 |
Annalisa | HowTo | COMSOL Tips | Mirror support Eigenfrequency |
I studied the eigenfrequencies of a mirror support using COMSOL.
|
Attachment 1: IronSupport.png
|
|
Attachment 2: IronSupportEigenfreq.png
|
|
8189
|
Wed Feb 27 18:38:51 2013 |
Riju | Update | | Photodiode transimpedance |
Quote: |
Quote: |
How much is the exact resonant frequency?
And what's the unit of the plot? The resonant "transimpedance" in the unit of Ohm can not be ~100.
|
The exact resonant frequency is 29.38MHz. I ve uploaded the other plot. It was the output of Vectfit.
|
Is the DC transimpedance now 10010 Ohm? I ve used 50 Ohm. Which one is correct? |
8188
|
Wed Feb 27 18:17:05 2013 |
Riju | Update | | Photodiode transimpedance |
Quote: |
How much is the exact resonant frequency?
And what's the unit of the plot? The resonant "transimpedance" in the unit of Ohm can not be ~100.
|
The exact resonant frequency is 29.38MHz. I ve uploaded the other plot. It was the output of Vectfit. |
8187
|
Wed Feb 27 18:01:46 2013 |
Koji | Update | | Photodiode transimpedance |
How much is the exact resonant frequency?
And what's the unit of the plot? The resonant "transimpedance" in the unit of Ohm can not be ~100. |
8186
|
Wed Feb 27 17:43:54 2013 |
Riju | Update | | Photodiode transimpedance |
Here is the transimpedance for the other PD used for MC REFL |
Attachment 1: TFnewreflpd.pdf
|
|
Attachment 2: NewREFL_z.pdf
|
|
8185
|
Wed Feb 27 14:59:01 2013 |
Evan | Update | | Altered MC demodulation phase |
I took out a short (~12 cm) SMA cable from the "LO input" path into the MC demod board in an attempt to maximize the power in Q and minimize the power in I. The path might benefit from being shortened a little more, but it's hard to tell since I is noisy. (In the attached plots, channel 1 is Q and channel 2 is I.)
Should you find it necessary to restore the original path length, the cable I took out is in the "SMA ONLY" tupperware and has a printed label with "5" on it. |
Attachment 1: Q_and_I_before.eps
|
|
Attachment 2: Q_and_I_after.eps
|
|
8184
|
Wed Feb 27 14:53:02 2013 |
Steve | Update | LSC | what is the Fibox ? |
Fibox FBAI-M 20bit units were connected with multimode fibre. This pair of fiber is not protected in the cable tray. |
8183
|
Wed Feb 27 14:39:59 2013 |
Annalisa | Update | LSC | Fibre laid for RFPD audio |
[Annalisa, Jenne, Rana, Steve]
We installed the fibres on cable trays the 1Y2 and the Control Room.
Still to do: find a power supply for the Fiboxes and plug everything in. |
8182
|
Wed Feb 27 11:59:43 2013 |
yuta | Update | SUS | PRM/BS coil re-balanced |
I re-adjusted coil gains and f2a filters for PRM and BS.
I'm not sure what happened to PRM since I balanced on Feb 16(elog #8093).
Let's see if it helps PRMI locking or not.
========== PRM ==========
- Original DC coil gains
C1:SUS-PRM_ULCOIL_GAIN 1.049901772380000e+00
C1:SUS-PRM_URCOIL_GAIN -9.833961907160000e-01
C1:SUS-PRM_LRCOIL_GAIN 9.543042546630000e-01
C1:SUS-PRM_LLCOIL_GAIN -9.713568522590000e-01
- New DC coil gains
multiplier factors are :
UL = 0.928167
UR = 1.061448
LR = 0.941659
LL = 1.068726
Set C1:SUS-PRM_ULCOIL_GAIN to 0.974482231437
Set C1:SUS-PRM_URCOIL_GAIN to -1.04382410014
Set C1:SUS-PRM_LRCOIL_GAIN to 0.898628670041
Set C1:SUS-PRM_LLCOIL_GAIN to -1.03811466772
- New f2p filters
- measured coupling coefficients are :
P2P(POS=>PIT) = 0.023968
P2Y(POS=>YAW) = 0.007075

========== BS ==========
- Original DC coil gains
C1:SUS-BS_ULCOIL_GAIN 1.037692431800000e+00
C1:SUS-BS_URCOIL_GAIN -1.016268296990000e+00
C1:SUS-BS_LRCOIL_GAIN 9.660800075010000e-01
C1:SUS-BS_LLCOIL_GAIN -9.791833500410000e-01
- New DC coil gains
multiplier factors are :
UL = 1.017855
UR = 1.023207
LR = 0.956184
LL = 1.002755
Set C1:SUS-BS_ULCOIL_GAIN to 1.0562177496
Set C1:SUS-BS_URCOIL_GAIN to -1.03985422464
Set C1:SUS-BS_LRCOIL_GAIN to 0.923750146975
Set C1:SUS-BS_LLCOIL_GAIN to -0.981880297098
- New f2p filters
- measured coupling coefficients are :
P2P(POS=>PIT) = 0.038251
P2Y(POS=>YAW) = -0.014677
 |
8181
|
Wed Feb 27 11:22:54 2013 |
yuta | Update | Computers | backup crontab |
I made a simple script to backup crontab (/opt/rtcds/caltech/c1/scripts/crontab/backupCrontab).
#!/bin/bash
crontab -l > /opt/rtcds/caltech/c1/scripts/crontab/crontab_$(hostname).$(date '+%Y%m%d%H%M%S')
I put this script into op340m crontab.
00 8 * * * /opt/rtcds/caltech/c1/scripts/crontab/backupCrontab
It took me 30 minutes to write and check this one line script. I hate shell scripts. |
8180
|
Wed Feb 27 02:52:40 2013 |
Jenne | Omnistructure | SAFETY | Back door unlocked |
Did someone unlock the back door by the (unofficial) bike storage lately? Out of habit, I checked the door behind me while about to leave, and it is unlocked.
Please recall that if you leave through that door, it should automatically lock behind you (if it was locked already), however if you unlock and enter through the back door, it stays unlocked until someone locks it again.
(Obviously, I'm locking the door before I actually go). |
8179
|
Wed Feb 27 02:44:39 2013 |
Jenne | Update | Locking | DRFPMI flashes |
Before Yuta left, I asked him to restore all optics to last saved values, to avoid hysteresis.
Some interesting modes appear at ETMYT and ETMXT. The cavities aren't super well aligned right now, especially since we have been seeing this input pointing drift, but it's cool to see our first DRFPMI flashes. SRM, in particular, hasn't been aligned since before pumpdown. If I misalign SRM, the mode content at the trans cameras improves somewhat, but it still isn't all low-order modes.
Here is the note that I wrote on youtube describing the video:
DRFPMI Flashing
Upper left is AS, upper right is POP
lower left is Xarm Trans (ETMXT), lower right is Yarm Trans (ETMYT)
Arms were last aligned several hours ago, and we know input pointing drifts, so at least some of the higher order modes in the arm transmissions are due to poor input pointing. All optics are "restored" to their last saved values, including SRM, which has not been aligned since before pumpdown.
TRX DC PD values are flashing to as high as 10
TRY DC PD values are flashing to as high as 7
Since uploading the video, I have seen TRY flash (once) to 45. Yes, forty five!!! Both arms are usually flashing to ~3ish, with an occasional medium flash (5-10), and then a few rare TRY flashes above 20.
We may have officially lost the bet of having arms locked by 9am Monday, but I think Team Grad Student / Postdoc still deserves some beer from Team Faculty / Staff. |
8178
|
Wed Feb 27 02:21:55 2013 |
Jenne | Update | ASS | Motivation for reactivating the ASS |
I have modified the MeasureSpotPositions.py script to accept the arms as valid cavities (it used to give an error "Sorry, this only works for MC right now").
There is still no wrapper script to turn on lockins and turn them off after the measurement, so I have not tested the arm A2L yet. But I should be able to tomorrow, or whenever the IFO is next available.
To-do:
* Write the wrapper script (analog of mcassMCdecenter).
* Fix arm assOff, assDown, assOn, assUp scripts to match the current channel names (which were changed long ago to be human-readable, versus mysterious numbers).
* Test. |
8177
|
Wed Feb 27 01:09:53 2013 |
yuta | Update | Locking | PRMI sideband/carrier locked |
[Jenne,Yuta]
We succeeded in locking PRMI in sideband and carrier.
Measured power recycling gain was ~60 power recycling gain was 4 (edited by YM on Feb 27; see elog #6947), but we have many things we cannot explain.
Snapshots:
Here you are, Jamie.
PRMI sideband locked
PRMI carrier locked

I centered POP camera and put attenuator to take these snapshots.
Compare with previous ones.
Aug 17, 2012 elog #7213
Jun 28, 2012 elog #6886
Mar 15, 2012 elog #6421
Locking details:
== MI only ==
MICH: AS55_Q_ERR, AS55_PHASE_R = -12 deg, MICH_GAIN = -7, feedback to BS
== PRMI sideband ==
MICH: AS55_Q_ERR, AS55_PHASE_R = 24.5 deg, MICH_GAIN = -0.05 (acquisition) -> -5 (UGF ~100 Hz), feedback to BS
PRCL: REFL33_I_ERR, REFL33_PHASE_R = -22.65 deg, PRCL_GAIN = 4 (UGF ~120 Hz), feedback to PRM
== PRMI carrier ==
MICH: AS55_Q_ERR, AS55_PHASE_R = 24.5 deg, MICH_GAIN = -0.08 (couldn't measure UGF), feedback to BS
PRCL: REFL33_I_ERR, REFL33_PHASE_R = -22.65 deg, PRCL_GAIN = -0.3 (couldn't measure UGF), feedback to PRM
Power recycling gain:
POPDC was 32 when PRM is misaligned, 25 when PRMI sideband locked, ~2000 when PRMI carrier locked.
This means, power recycling gain is ~60 power recycling gain is ~4 (=POPlocked/POPmis*T_PRM=2000/30*0.06). Expected power recycling gain for PRMI is ~45, when there's no loss (see elog #6947).
I reduced POPDC PD gain so that it doesn't saturate.
Issues:
- We optimized AS55_PHASE_R to -12 deg by looking at MI signal. But somehow, -12 deg didn't work for PRMI.
- Somehow, REFL11_I didn't work to lock PRCL.
- REFL11_Q didn't work to lock MI. SNR not enough?
- We saw POPDC flashing up to ~15000. What is this?
- Carrier lock was not stable, we couldn't hold for more than ~30 sec. It looks like PRM moves too much when PRMI is locked.
- Input pointing is drifting a lot in pitch. I had to re-align TT2/TT1 to the arms every ~1 hour to get good MI alignment. When I tweak TT2/TT1, both TRY and TRX gets better. I think this shows that input pointing is drifting, not the arms.
Next:
- redo PRM/BS coil balancing
- optimize REFL33 rotation phase
- stabilize carrier lock somehow
- measure PRC g-factor
|
8176
|
Wed Feb 27 00:56:01 2013 |
Jenne | Update | ASS | Motivation for reactivating the ASS |
I am putting a little bit of brain power into reviving the ASS, and I want to write down what the motivation is, and what the short and long-term plans are.
Why?
The IFO IR is not optimally aligned right now. While we were at atmosphere, we should have taken the time to align the green beams to the arms until the greens were both resonating TEM00. We were lazy, and excited to pump down, so we decided that locking on higher order modes was good enough to ensure the beams came out of vacuum. Once we were pumped down, ITMY and ETMY were aligned to the green beam axis. Then, the IR was aligned to this new Yarm cavity axis. This would have been okay, and pretty close, if we had aligned the green beam all the way (used only the outside steering mirrors to resonate TEM00, after the cavity mirrors were aligned for flashing IR). After the IR was aligned to the Ygreen axis, the rest of the IFO was aligned to this slightly-incorrect input pointing. We want to measure the IR spot positions on ITMY and ETMY so that we can tweak the input pointing until we hit the center of both ITMY and ETMY. Then we will align Ygreen's input pointing to this proper IR cavity axis. The rest of the IFO alignment will also have to be redone. This calls for a functioning A2L system, so the measurement part of the ASS.
The immediate motivation for measuring the spot positions is that the current Xarm IR axis is not at all very close to the Xgreen axis. The other day while we were fixing up the Xend table (note in elog 8162), we found that the TRX beam to the TRX PD and the trans camera was clipped on the 2" harmonic separator (which is the first optic that the transmitted IR beam sees on the end tables). It was clipping on the left side of the optic, if you are looking at the face of the optic. This is the more east-erly side of the optic. We moved that optic to the side so that we were not clipping. Then, today when Manasa was trying to align the Xgreen beam, she found that it was clipping on the right side of the harmonic separator, the more west-erly side. I remember seeing that the green beam was roughly centered on the harmonic separator when we were at atmosphere, so this clipping is certainly due to Yuta, Evan and my moving of the harmonic separator. Since the end green steering optics are not very orthogonal in angle/translation, it is very difficult to translate the beam by a significant amount. If we keep the current IR alignment, which surely isn't good anyway (you can see on the ETMXF camera that the beam isn't centered), we would probably have to move the Xgreen steering optics, which would be a total pain. It seems that the better plan is to leave them where they are, and get the IR pointing in the correct direction, and move the harmonic separator back to where it was originally.
Short term (< few days):
Write the arm section of the existing MeasureSpotPositions.py script (in ....../scripts/ASS). Write a wrapper script that, like ...../scripts/ASS/MC/mcassMCdecenter, calls sets up the lockins, runs MeasureSpotPositions.py, and calculates the calibrated spot positions. Use this information to hand tweak the input pointing, then realign the cavities to the new IR, and the greens to the new cavity axes.
All of the infrastructure for this is already in place in the c1ass model. The only drawback to the current situation is the LSC output matrix only has one row for ASS, and so only one cavity can be measured at a time. To make things faster, we could consider increasing the size of the LSC output matrix so that the 2 arms could be measured simultaneously. This change is low priority for now.
Long term:
Make the full ASS system work.
A major change from the current situation is that the current ASS cannot actuate on the input pointing (TT1 and TT2 for Yarm, BS for Xarm). We want a low bandwidth servo to force the input beam to follow the cavity axis. Implementing this will require some changes to the ASS model.
Remeasure sensing matrix, test system. |
8175
|
Wed Feb 27 00:08:43 2013 |
Jenne | Update | IOO | Meditations on converting TT channels to be more SUS-like |
Jamie and I have had a few back-and-forths on this, but I wanted to write down my thoughts on the parts of the SUS infrastructure that we need for the active tip tilts.
I think we want the ASC pitch and yaw filter banks. I also think we want to change the channel names so that they are C1:SUS rather than C1:IOO, to make scripting easier. A corollary to this is that we should make the DC bias sliders have the same naming structure as the regular suspensions (C1:SUS-TT#_{PIT/YAW}_COMM). This makes scripts like the save/restore scripts easier. If we keep the IOO naming, it would still be convenient to add the _COMM.
I am having trouble imagining what we might want the lockins for, so I propose we leave them out.
Do we want the output matrix (PIT/YAW -> coils) to be a filter bank matrix? If we want f2a filters, we need to change this to a filter bank matrix.
I also think we want a master on/off switch for the AC actuation (ASC stuff). We don't have sensors, so we won't have watchdog-ing, but it might be useful to have a 'panic' switch. Perhaps though if we are careful to set limits on the ASC filter banks, we won't ever have a panic about actuating too hard.
I'm think I'm joining Jamie's side in the medm screen debate....I think we want a separate TT_SINGLE screen, laid out similar to the SUS_SINGLE, but without all of the irrelevant parts.
EDIT: Yuta just pointed out to me that right now, the TT DC bias sliders are not recorded anywhere (_DQ, conlog,...). We *must* fix this. |
8174
|
Tue Feb 26 17:56:15 2013 |
Brett | Update | SUS | Global Damping Update |
The global damping input and output matrices were installed to run for the Y-arm. Since we are using just one arm for now, only the DARM and CARM DOFs were entered into the matrices.
The input matrix was set to have elements with magnitudes of 0.5 while the output matrix was set to have elements with magnitudes of 1. The input matrix gets the 0.5 because the sensor signals must be avergaed for each global DOF, to make an 'equivalent sensor' with the same gain. The output matrix gets magnitudes of 1 so that the overall gain of the global loops is the same as the local loops. A transfer function was measured on the CARM loop to check that the overall gain is in fact the same as the measured ITMY and ETMY loops.
Simple damping filters were installed for the ITMY and ETMY as well as the global y arm CARM and DARM loops.
The ETMY output tuning filter ETMY_GLOBPOS was set to have a gain of 0.4 because there is an extra gain of 2.5 relative to ITMY in some mysterious place as discussed in log 8172. |
8173
|
Tue Feb 26 17:36:28 2013 |
Chloe | Update | | QPD Circuit |
I corrected the circuit diagram I constructed last time - it would read 0 output most of the time because I made a mistake with the op amps. This will be attached once I discuss it with Eric.
I searched the 40m lab and ended up finding a breadboard in the Bridge lab. I then spent awhile trying to remove the QPD from the circuit board it was on, which was difficult since it had 6 pins. After that, I soldered wires to the QPD legs and began constructing the circuit on the breadboard. I also spent time showing Annalisa the setup and explaining my project.
On Friday I will try and reconstruct all of the circuitry from before for the QPD. |
8172
|
Tue Feb 26 16:13:18 2013 |
Brett | Update | SUS | ITMY and ETMY mysterious loop gain difference of 2.5 |
While doing initial measurements for the new global damping infrastructure I discovered that the ETMY loop between the OSEM actuation and the OSEM sensors has a gain that is 2.5 times greater than the ITMY. The result is that to get the same damping on both, the damping gain on the ETMY must be 2.5 times less than the ITMY. I do not know where this is coming from, but I could not find any obvious differences between the MEDM matrices and gains.
I uploaded a screenshot of measured transfer functions of the damped ITMY and ETMY sus's. Notice that the ETMY measurement is 2.5 times higher than the ITMY. The peak also has a lower Q, despite having the same damping filters running because of this mysterious gain difference. Lowering the damping gain of the ETMY loop by this 2.5 factor results in similar Q's. |
Attachment 1: Screenshot.png
|
|
8171
|
Tue Feb 26 15:32:47 2013 |
Jenne | Update | Locking | FPMI locked |
Quote: |
P.S. TRX seems to be moving less on the camera because of the oplevs centered and working from last night.
|
Ah, yes. I forgot to mention in my elog last night that Yuta and I found that the ITMX oplev servo had been on, even though the oplev beam was blocked, so ITMX was noisier than it should have been. |
8170
|
Tue Feb 26 11:55:11 2013 |
Manasa | Update | Locking | FPMI locked |
[Yuta, Manasa]
FPMI locked.
Alignment and lock acquisition
1. Use ITMY/ETMY to maximize green transmission in Y arm (to get closer to arm alignment).
2. Use TT1/TT2 to align arms to IR to the Y-arm (Maximum TRY = 0.84)
3. Use BS/ITMX/ETMX to align IR to the X-arm.
4. Use POY11_I and POX11_I to lock Yarm and Xarm.
5. Use ASDC to lock MI.
Modified
1. X-arm trans camera settings changed.
2. Blocked stray green from reaching TRX PD and camera.
P.S. TRX seems to be moving less on the camera because of the oplevs centered and working from last night.
Plan
Lock green to X arm.
|
8169
|
Tue Feb 26 10:20:31 2013 |
Jamie | Update | SUS | MC2 suspension controller reverted to library part |
I made good on my threat from yesterday to convert the MC2 suspension controller to the library part. Whatever changes were in MC2 were thrown out, although they are archived in the SVN. Again, this kind of undocumented breaking is forbidden.
Change was committed to SVN, and c1mcs was recompiled/installed/restarted. |