ID |
Date |
Author |
Type |
Category |
Subject |
8068
|
Tue Feb 12 18:25:43 2013 |
Jamie | Summary | General | half PRC with astigmatic PR2/3 |
Quote: |
|
arbcav |
a la mode |
measurement |
g tangential |
0.9754 |
0.9753 |
0.986 +/- 0.001 |
g sagital |
0.9686 |
0.9685 |
0.968 +/- 0.001 |
|
Given that we're measuring different g parameters in the tangential and sagittal planes, I went back to alamode to see what astigmatism I could put into PR2 and/or PR3 to match what we're measuring. I looked at three cases: only PR2 is astigmatic, only PR3 is, or where we split the difference. Since the sagittal measurement matches, I left all the sagittal curvatures the same in
case 1: PR3 only
|
PR2 RoC (m) |
PR3 RoC (m) |
g (half PRC) |
tangential |
706 |
-420 |
0.986 |
sagittal |
706 |
-700 |
0.969 |
case 2: PR3 only
|
PR2 RoC (m) |
PR3 RoC (m) |
g (half PRC) |
tangential |
5000 |
-700 |
0.986 |
sagittal |
706 |
-700 |
0.969 |
case 3: PR2 and PR3
|
PR2 RoC (m) |
PR3 RoC (m) |
g parameter |
tangential |
2000 |
-600 |
0.986 |
sagittal |
706 |
-700 |
0.969 |
From Koji's post about the scans of the G&H mirrors, it looks entirely reasonable that we could have these levels of astigmatism in the optics.
What this means for full PRC
These all make the same full PRC situation:
g (tangential): 0.966
g (sagittal): 0.939
ARM mode matching: 0.988
|
8067
|
Tue Feb 12 17:26:31 2013 |
Chloe | Update | | QPD circuitry to test mount vibrations | I spent awhile today reading about op-amps and understanding what would be necessary to design a circuit which would directly give pitch and yaw of the QPD I am using. After getting an idea of what signals would be summed or subtracted, I opened up the QPD to take better pictures than last time (sorry, the pictures were blurry last time and I didn't realize). It turns out some of the connections have been broken inside the QPD, which would explain why we saw an unchanging signal in Ch2 on the oscilloscope yesterday when trying to test the laser setup.
I found a couple other QPDs, which I will be using to help understand the circuit (and what is going on). I will be trying to use the same QPD box since it has banana cable and BNC cable adapters, which is helpful to have in the lab. Once I have concluded what the circuitry is like and designed electronics to add and subtract signals, I will build and mount all the circuits within the box (more sturdily than last time) so as to have a quality way of measuring the mount vibrations when I get there. |
8066
|
Tue Feb 12 00:50:08 2013 |
yuta | Update | Locking | PR2 oplev spectra | I wanted to see if PR2 motion makes PRC beam motion or not, using temporary oplev to PR2.
I could not measure the coherence between beam motion and PR2 motion, because I couldn't lock half-PRC today.
But I took spectra of PR2 oplev anyway.
Result:
Below are the spectra of PR2 oplev outputs (taken using C1:SUS-ITMX_OL(PIT|YAW)_IN1). Bottom plot is POP DC during half-PRC locked yesterday.

Discussion:
We see bump in PR2 oplev output at ~ 2-3 Hz. But we cannot say this is a evidence for PR2 motion making PRC beam motion because no coherence measurement was done. Also, oplev might be just seeing the ITMX stack motion.
Resonant frequency of TTs measured were at ~ 1.8-1.9 Hz (elog #8054), but we cannot clearly see these peaks in oplev outputs. Did resonant frequency shifted because of different damping condition? |
8065
|
Tue Feb 12 00:14:00 2013 |
yuta | Update | Locking | PRM coil balancing | We tried to lock half-PRC tonight, but we couldn't. Why?? I could lock yesterday.
It locks for ~ 1 sec, but it beam spot motion freaks out mainly in yaw.
I tried to balance PRM coils, but oplev beam was clipped by MMT1......
What I did:
1. Found elog #5392 and found F2P_LOCKIN.py
2. Modified F2P_LOCKIN.py because LOCKIN channel names are some how changed like this;
LOCKIN1_I -> LOCKIN1_DEMOD_I
LOCKIN1_Q -> LOCKIN1_DEMOD_Q
LOCKIN1_SIG -> LOCKIN1_DEMOD_SIG
3. Running
/opt/rtcds/caltech/c1/scripts/SUS/F2P_LOCKIN.py -o PRM
should adjust (UL|UR|LR|LL)COIL_GAINs by putting some gain imbalance and shaking the mirror in different frequencies. It uses LOCKIN to OL(PIT|YAW).
4. Since there was no PRM oplev beam coming out from the vacuum, I quickly looked into BS-PRM chamber. Oplev beam was clipped by MMT1. If I adjust PRM slider values to avoid clipping, the beam will be clipped by mirrors on oplev table. What happened to the PRM oplev?
5. I also made bunch of /opt/rtcds/userapps/trunk/sus/c1/medm/templates/SUS_SINGLE_LOCKIN(1|2)_DEMOD_(I|Q|SIG).adl because there were missing screens.
Next:
We need to restore the PRM oplev and balance the coils. See, also, elog #7679 |
8064
|
Mon Feb 11 21:03:15 2013 |
yuta | Update | Locking | PR2-flipped half-PRC mode scan | To estimate the systematic effects to the g-factor measurement, I changed how to analyze the data in multiple ways.
From the estimation, I get the following g-factors for half-PRC;
tangential: 0.986 +/- 0.001(stat.) +/- 0.008(sys.)
sagittal: 0.968 +/- 0.001(stat.) +/- 0.003(sys.)
The a la mode/arbcav calculation is not so far from the measurement(elog #8059). So, mirror curvatures and lengths are not far from what we expect.
Method:
Method I used to analyze the mode scan data is as follows;
1. Use the spacing between upper sideband and lower sideband to calibrate the data.
2. Measure the position of 00, 1st, 2nd and 3rd mode.
3. Used the following formula to get TMS
nu_TMS = sum((n_i-n)*(nu_i-nu)) / sum((n_i-n)^2)
where n_i is the order of transverse mode, n is average of n_i's, nu_i is the frequency if i-th order mode and nu is average of nu_i's. This is just a linear fitting.
But since it is hard to resolve where the higher order mode is, it is maybe better to use only 00, 1st, and 2nd mode. Also, since cavity sweep is not linear enough, it is maybe better to use spacing between 00 and lower sideband (sideband closer to HOMs) to calibrate the data. Changing the analysis will give us information about the effect of peak choosing and linearity.
How the result differ:
Below are the plots of order of tranverse mode vs measured relative frequency difference from 00 mode. 5 plots on left are when PRM is misaligned in pitch and right are same in yaw. From the plot, you can see using 3rd order mode tend to give larger TMS. Did I picked the wrong one??
left: right:
Results:
Below table is the result when I changed the analyzing method;
PRM misaligned in pitch
calibration how many HOMs measured g-factor
upper-lower up to 3rd 0.968
upper-lower up to 2nd 0.974
upper-lower up to 1st 0.975
00-lower up to 3rd 0.952
00-lower up to 2nd 0.962
00-lower up to 1st 0.963
PRM misaligned in yaw
calibration how many HOMs measured g-factor
upper-lower up to 3rd 0.986
upper-lower up to 2nd 0.989
upper-lower up to 1st 0.991
00-lower up to 3rd 0.964
00-lower up to 2nd 0.988
00-lower up to 1st 0.991
Using 00-lower calibration tend to give us smaller g-factor. Using less higer order-mode tend to give us higher g-factor.
By taking standard deviation of these, I roughly estimated the systematic error as above.
Discussion:
I think it is OK to move on to PRMI now.
But I wonder how much astigmatism is needed to get this measurement data. If astigmatism is not so crazy, it's OK. But if it's not, I think it is better to do more measurement like PRM-PR2-TM cavity. |
8063
|
Mon Feb 11 19:55:47 2013 |
Manasa | Update | Optics | G&H - AR Reflectivity |
I adjusted the focal length of the focusing lens and reduced the beam size enough to mask with the razor blade edge while looking at the camera and then making measurements using PD.
I am still not satisfied with this data because the R of the HR surface measured after flipping seems totally unbelievable (at around 0.45).
G&H AR reflectivity
R percentage
11 ppm @4 deg
19.8 ppm @6 deg
20 ppm @ 8 deg
30 ppm @ 20 deg |
8062
|
Mon Feb 11 18:44:34 2013 |
Jamie | Update | Computers | passwerdz changed |
Password for nodus and all control room workstations has been changed. Look for new one in usual place.
We will try to change the password on all the RTS machines soon. For the moment, though, they remain with the old passwerd. |
8061
|
Mon Feb 11 18:39:10 2013 |
Chloe | Update | General | Pictures of Circuitry in Photodiode | I am going to be making measurements to find the optical mounts with the least noise. I am using a quadrature photodiode to record intensity of laser light. These are pictures of the circuitry inside (both sides). I will be designing/making some circuitry on a breadboard in the next few days in order to add and subtract the signals to have pitch and yaw outputs. |
Attachment 1: IMG_0327.JPG
|
|
Attachment 2: IMG_0329.JPG
|
|
8060
|
Mon Feb 11 17:54:02 2013 |
Koji | Summary | Optics | Curvature radii of the G&H/LaserOptik mirrors | I, by chance, found that my windows partition has Vision32 installed.
So I run my usual curvature characterization for the TT phasemaps.
They are found under this link
https://nodus.ligo.caltech.edu:30889/40m_phasemap/40m_TT/(requires: LVC credentials)
or
/cvs/cds/caltech/users/public_html/40m_phasemap/40m_TT
asc/ (ascii files) --> .asc files are saved in Wyko ascii format.
bmp/ (screen shots of Vision32)
mat/ (Matlab scripts and results)
opd/ (Raw binary files)
Estimated radius of curvature
Mirror / RoC from Vision32 / RoC from KA's matlab code
G&H "A" 0864 / -527.5 m / -505.2 m
G&H "B" 0884 / -710.2 m / -683.6 m
LaserOptik SN1 / -688.0 m / -652.7 m
LaserOptik SN2 / -605.2 m / -572.6 m
LaserOptik SN3 / -656.7 m / -635.0 m
LaserOptik SN4 / -607.5 m / -574.6 m
LaserOptik SN5 / -624.8 m / -594.3 m
LaserOptik SN6 / -658.5 m / -630.2 m
The aperture for the RoC in Vision32 seems a bit larger than the one I have used in the code (10mm in dia.)
This could be the cause of the systematic difference of the RoCs between these, as most of our mirrors
has weaker convex curvature for larger aperture, as seen in the figure. (i.e. outer area is more concave
after the subtration of the curvature)
I did not see any structure like Newton's ring which was observed from the data converted with SXMimage. Why??? |
Attachment 1: TT_Mirrors_RoC.pdf
|
|
8059
|
Mon Feb 11 17:17:30 2013 |
Jamie | Summary | General | more analysis of half PRC with flipped PR2 |
Quote: |
We need expected finesse and g-factor to compare with mode-scan measurement. Can you give us the g-factor of the half-PRC and what losses did you assumed to calculate the finesse?
|
This is exactly why I added the higher order mode spacing, so you could calculate the g parameter. For TEM order N = n + m with spacing f_N, the overall cavity g parameter should be:
g = (cos( (f_N/f_FSR) * (\pi/N) ))^2
The label on the previous plat should really be f_N/FSR, not \omega_{10,01}
BUT, arbcav does not currently handle arbitrary ABCD matrices for the mirrors, so it's going to be slightly less accurate for our more complex flipped mirrors. The affect would be bigger for a flipped PR3 than for a flipped PR2, because of the larger incidence angle, so arbcav will be a little more correct for our flipped PR2 only case (see below).
Quote: |
Also, flipped PR2 should have RoC of - R_HR * n_sub (minus measured RoC of HR surface multiplied by the substrate refractive index) because of the flipping.
|
This is not correct. Multiplying the RoC by -N would be a very large change. For an arbitrary ABCD matrix:
R_eff = -2 / C
When the incident angle in non-zero:
tangential: R_eff = R_eff / cos(\theta)
sagittal: R_eff = R_eff * cos(\theta)
For flipped PR2, with small 1.5 degree incident angle and RoC of -706 at HR:
M_t = M_s = [1.0000, 0.0131; -0.0028, 1.0000]
R_eff = 705.9
For flipped PR3, with large 41 degree incident angle and RoC of -700 at HR:
M_t = [1.0000, 0; 0.0038, 1.0000]
M_s = [1.0000, 0; 0.0022, 1.0000]
R_eff = 592.4
The affect of the substrate is negligible for flipped PR2 but significant for flipped PR3.
The current half-PRC setup
OK, I have now completely reconciled my alamode and arbcav calculations. I found a small bug in how I was calculating the ABCD matrix for non-flipped TTs that made a small difference. I now get the exact same g parameter values with both with identical input parameters.
Quote: |
According to Jenne dictionary, HR curvature measured from HR side is;
PRM: -122.1 m
PR2: -706 m
PR3: - 700 m
TM in front of BS: -581 m
|
Sooooo, I have redone my alamode and arbcav calculations with these updated values. Here are the resulting g parameters
|
arbcav |
a la mode |
measurement |
g tangential |
0.9754 |
0.9753 |
0.986 +/- 0.001 |
g sagital |
0.9686 |
0.9685 |
0.968 +/- 0.001 |
So the sagittal values all agree pretty well, but the tangential measurement does not. Maybe there is an actual astigmatism in one of the optics, not due to angle of incidence?
arbcav HOM plot:

|
8058
|
Mon Feb 11 16:29:33 2013 |
Jenne | Update | Locking | Temp oplev for PR2; ITMX temporarily has no oplev | [Yuta, Jenne]
In an effort to see what is going on with the beam spot motion, and to investigate whether or not it might be caused by passive TT motion, Yuta and I installed some oplev mirrors in-vac, to make a PR2 oplev.
Yuta did not move either of the in-vac oplev mirrors that are for ITMX. Instead, he took the incident red beam as it was, and put a spare in-vac oplev mirror there. Then he used another spare oplev mirror to get the beam out, and on to the one out-of-vac steering mirror before the QPD. I then steered the out of vac mirror to center the beam on the QPD.
This means (1) that ITMX cannot have an oplev right now, although the HeNe was off anyway, and (2) that as soon as we take these spare oplev mirrors out, we should immediately have ITMX oplev back (may need to steer out of vac mirror to get beam onto QPD).
Yuta is currently taking measurements to see if PR2 motion has high coherence with the intracavity motion. |
8057
|
Mon Feb 11 16:16:27 2013 |
Steve | Update | VAC | 55 days at atmoshere | CP Stat 100 sheet-covers were replaced by clean ones on open chambers BS, ITMX, ITMY and ETMY this morning.
Try to fold the sheets such way that the clean side is facing each other, so they do not accumulate dust.
|
Attachment 1: atm55d.png
|
|
8056
|
Mon Feb 11 13:15:16 2013 |
yuta | Update | Locking | PR2-flipped half-PRC mode scan | I found a mistake in my code (thanks Jamie!).
I forgot to square the g-factor.
I corrected the following elogs;
PRM-PR2 cavity
elog #7994 : g-factor will be 0.9889 +/- 0.0004
elog #8012 : g-factor is 0.988812630228 pm 0.000453751681357
half-PRC g-factor
elog #8040 : g-factor is 0.9800 +/- 0.0001
elog #8052 : sagittal g-factor is 0.968 +/- 0.001 and tangential g-factor is 0.986 +/- 0.001
I checked that I was correct in July 2012 (elog #6922)
Cavity g-factor formula:
gm = ( cos(pi*nu_TMS/nu_FSR) )**2 |
8055
|
Mon Feb 11 13:07:17 2013 |
Max Horton | Update | Summary Pages | Fixed A Calendar Bug | Understanding the Code: Documented more functions in summary_pages.py. Since it is very difficult and slow to understand what is going on, it might be best to just start trying to factor out the code into multiple files, and understand how the code works from there.
Crontab: Started learning how the program is called by cron / what cron is, so that I can fix the problem that forces data to only be displayed up until 6PM.
Calendars: One of the problems with the page is that the calendars on the left column didn't have any of the months of 2013 in them.
I identified the incorrect block of code as:
Original Code:
# loop over months
while t < e:
if t.month < startday.month or t >= endday:
ptable[t.year].append(str)
else:
ptable[t.year].append(calendar_link(t, firstweekday, tab=tab, run=run))
# increment by month
# Move forward day by day, until a new month is reached.
m = t.month
while t.month == m:
t = t + d
# Ensure that y still represents the current year.
if t.year > y:
y = t.year
ptable[y] = []
The problem is that the months between the startday and endday aren't being treated properly.
Modified Code:
# loop over months
while t < e:
if (t.month < startday.month and t.year <= startday.year) or t >= endday:
ptable[t.year].append(str)
else:
ptable[t.year].append(calendar_link(t, firstweekday, tab=tab, run=run))
# increment by month
# Move forward day by day, until a new month is reached.
m = t.month
while t.month == m:
t = t + d
# Ensure that y still represents the current year.
if t.year > y:
y = t.year
ptable[y] = []
After this change, the calendars display the year of 2013, as desired.
|
8054
|
Mon Feb 11 12:49:54 2013 |
Jenne | Summary | LSC | Resonant freq change - why? (and passive TT mode freqs) |
Quote: |
Is it because of the change in the resonant frequency of the BS-PRM stack? How much the load on BS-PRM changed?
Or is it because of the change in the resonant frequency of PR2/PR3
|
I claim that neither of those things is plausible. We took out 1 PZT, and put in 1 active TT onto the BS table. There is no way the resonant frequency changed by an appreciable amount due to that switch.
I don't think that it is the resonant frequency of the TTs either. Here, I collate the data that we have on the resonant frequencies of our tip tilts. It appears that in elog 3425 I recorded results for TTs 2 and 3, but in elog 3447 I just noted that the measurements had been done, and never put them into the elog. Ooops.
Resonant frequency and Q of modes of passive tip tilts.
|
Vertical |
Yaw |
Pos |
Side |
TT1 |
f0=20, Q=18 |
f0=1.89, Q=3.8 |
f0=1.85, Q=2 |
f0=1.75, Q=3.2 |
TT2 |
f0=24, Q=7.8 |
f0=1.89, Q=2.2 |
f0=1.75, no Q meas |
f0=1.8, Q=4.5 |
TT3 |
f0=20, Q=34 |
f0=1.96, Q="low" |
f0=1.72, Q=3.3 |
f0=1.85, Q=6 |
TT4 |
f0=21, Q=14 |
f0=1.88, Q=2.3 |
f0=1.72, Q=1.4 |
f0=1.85, Q=1.9 |
TT5 |
f0=20, Q=22.7 |
no measurement |
f0=1.79, Q=1.8 |
f0=1.78, Q=3.5 |
Notes: "Serial Number" of TTs here is based on the SN of the top suspension point block. This does not give info about which TT is where. Pitch modes were all too low of Q to be measured, although we tried.
Tip tilt mode measurements were taken with a HeNe and PD shadow sensor setup - the TT's optic holder ring was partially obscuring the beam. |
8053
|
Sun Feb 10 18:00:13 2013 |
yuta | Summary | LSC | PR2-flipped half-PRC spectra/OLTF | To compare with future PRMI locking, I measured spectra of POPDC and feedback signal. I also measured openloop transfer function of half-PRC locking.
Beam spot motion was at ~ 2.4 Hz, not 3.3 Hz.
Results:
Below is uncalibrated spectra of POPDC and LSC feedback signal (C1:LSC-PRM_OUT).

Below is openloop transfer function of the half-PRC locking loop. UGF is ~ 120 Hz and phase margin is ~ 45 deg. This agrees with the expected curve.

Data was taken when half-PRC was locked using REFL11_I as error signal and actuating on PRM.
Discussion:
For comparison, POPDC when PRMI was locked in July 2012: elog #6954 and PRCL openloop transfer function: elog #6950.
Peak in the spectra of POPDC and feedback signal was at ~ 3.3 Hz in July 2012 PRMI, but it is now at ~ 2.4 Hz in half-PRC. The peak also got broader.
Is it because of the change in the resonant frequency of the BS-PRM stack? How much the load on BS-PRM changed?
Or is it because of the change in the resonant frequency of PR2/PR3?
Phase margin is less now because of gain boost ~ 5 Hz and resonant gain at 24 Hz.
|
8052
|
Sun Feb 10 17:30:39 2013 |
yuta | Update | Locking | PR2-flipped half-PRC mode scan | I redid half-PRC mode scan by applying mislignment to PRM.
Half-PRC's sagittal g-factor is 0.9837 +/- 0.0006 and tangential g-factor is 0.9929 +/- 0.0005.
sagittal g-factor is 0.968 +/- 0.001 and tangential g-factor is 0.986 +/- 0.001. (Edited by YM; see elog #8056)
Method:
1. Same as elog #8049, but with small misalignment to PRM.
2. Algined half-PRC, and misaligned PRM in pitch to get sagittal g-factor.
3. Restored pitch alignment and misaligned PRM in yaw to get tangential g-factor.
Result:
Below left is the plot of POP DC and PRCL error signal (REFL11_I) when PRM is misaligned in pitch. Below left is the same plot when misaliged in yaw.
left: right:
By averaging 5 sets of peaks around TEM00, I get sagittal/tangential g-factors written above.
Discussion:
The fact that tangential g-factor is larger than sagittal g-factor comes from astigmatism mainly from PR3. Effective PR3 curvature is
sagittal Re = R/cos(theta) = -930 m
tangential Re = R*cos(theta) = -530 m (where R = -700 m , theta = 41 deg)
so, PR3 is more convex in tangential plane and this makes half-PRC close to unstable. This is opposite of Jamie's calculation(elog #8022). I'm confused.
I first thought I don't need to misalign PRM because alignment was not so good - it was hard to align when beam motion is large. Also, this motion makes angular misalignment, so I thought free swinging is enough to make higher order modes. However, misaligning PRM intentionally made it easier to resolve higher order modes. I could even distinguish (10,01) and (20,11,02), as you can see from the plot.
Next:
We have to compare with expected g-factor before moving on to PRMI. |
8051
|
Sat Feb 9 19:34:34 2013 |
rana | Update | Optics | G&H - AR Reflectivity |
Use the trick I suggested:
Focus the beam so that the beam size at the detector is smaller than the beam separation. Use math to calculate the beam size and choose the lens size and position. You should be able to achieve a waist size of < 0.1 mm for the reflected beam. |
8050
|
Sat Feb 9 11:25:35 2013 |
Koji | Update | Locking | PR2-flipped half-PRC mode scan | Don't Shouldn't you apply a small misalignment to the input beam? Isn't that why the peak for the 1st-order is such small?
Quote: |
Method
1. Aligned half-PRC using input TT1 and TT2 by maximizing POP DC during lock. It was not so easy because POP DC fluctuates much at ~ 3 Hz with amplitude of ~ 30 % of the maximum value because of the beam motion (movie on elog #8039).
2. Unlocked half-PRC and took POP DC and PRC error signal data;
> /opt/rtcds/caltech/c1/scripts/general/getdata -d 1 -o /users/yuta/scripts/PRCmodescan C1:LSC-POPDC_OUT C1:LSC-REFL11_I_ERR
Ran again and again until I get sufficiently linear swing through upper/lower sidebands.
|
|
8049
|
Fri Feb 8 23:59:42 2013 |
yuta | Update | Locking | PR2-flipped half-PRC mode scan | I did mode scan of PR2-flipped half-PRC to see if it behaves as we expect.
Measured finesse was 107 +/- 5 and g-factor is 0.98997 +/- 0.00006.
g-factor is 0.9800 +/- 0.0001. (Edited by YM; see elog #8056)
Finesse tells you that we didn't get large loss from flipped PR2.
Since we have convex TM in front of BS, PRC will be more stable than this half-PRC.
Method:
1. Aligned half-PRC using input TT1 and TT2 by maximizing POP DC during lock. It was not so easy because POP DC fluctuates much at ~ 3 Hz with amplitude of ~ 30 % of the maximum value because of the beam motion (movie on elog #8039).
2. Unlocked half-PRC and took POP DC and PRC error signal data;
> /opt/rtcds/caltech/c1/scripts/general/getdata -d 1 -o /users/yuta/scripts/PRCmodescan C1:LSC-POPDC_OUT C1:LSC-REFL11_I_ERR
Ran again and again until I get sufficiently linear swing through upper/lower sidebands.
3. Ran modescan analyzing scripts (elog #8012).
Result:
Below is the plot of POP DC and PRCL error signal (REFL11_I).

By averaging 5 sets of peaks around TEM00;
Time between TEM00 and sideband 0.0347989 pm 0.00292257322372 sec
Calibration factor is 317.995971137 pm 26.7067783894 MHz/sec
FSR is 34.5383016129 MHz
FWHM is 0.323979022488 pm 0.0145486106353 MHz
TMS is 1.55827297374 pm 0.00439737672808 MHz
Finesse is 106.606598624 pm 4.78727876459
Cavity g-factor is 0.989971692098 pm 5.65040851566e-05
Cavity g-factor is 0.980043951156 pm 0.000111874889586
Discussion:
Measured finesse is similar to measured PRM-PR2 cavity finesse(108 +/- 3, see elog #8012). This means loss from flipped PR2 and beam path from PR2 to TM is small.
I'm a little suspicious about measured g-factor because it is hard to tell which peak is which from the mode scan data. Since half-PRC was not aligned well, high HOMs may contribute to POP DC. Astigmatism also splits HOM peaks.
PRC 3 Hz beam motion was there for long time (see, for example, elog #6954). BS is unlikely to be the cause because we see this motion in half-PRC, too.
Also, beam spot motion was not obvious in the PRM-PR2 cavity. My hypothesis is; stack resonance at 3 Hz makes PR2/PR3 angular motion and folding by PR2/PR3 makes the beam spot motion.
Next things to do:
* PRC g-factor
- Calculate expected half-PRC g-factor with real measured curvatures, with error bar obtained from RoC error and length error (JAMIE)
- Calculate expected PRC g-factor using measured half-PRC g-factor (JAMIE)
* PRC 3 Hz beam motion
- Do we have space to put oplevs for PR2/PR3?
- Can we fix PR2/PR3 temporarily?
* PRMI
- Align incident beam, BS, REFL, AS, and MI using arms as reference
- lock PRMI
- PRC mode scan |
8048
|
Fri Feb 8 23:22:48 2013 |
Den | Summary | Modern Control | progress report | I wrote a small document on the application of LQG method to a Fabry-Perot cavity control. |
Attachment 1: LQG.pdf
|
|
8047
|
Fri Feb 8 23:04:40 2013 |
Manasa | Update | Optics | G&H - AR Reflectivity |
Quote: |
D = 2 d Tan(\phi) Cos(\theta), where \phi = ArcSin(Sin(\theta) * n)
\theta is the angle of incidence. For a small \theta, D is propotional to \theta.
|
n1Sin(\theta1) = n2 Sin(\theta2)
So it should be
\phi = ArcSin(Sin(\theta) / n
I did check the reflected images for larger angles of incidence, about 20 deg and visibly (on the IR card) I did not see much change in the separation. But I will check it with the camera again to confirm on that. |
8046
|
Fri Feb 8 22:49:31 2013 |
Koji | Update | Optics | G&H - AR Reflectivity | How about to measure the AR reflectivity at larger (but small) angles the extrapolate the function to smaller angle,
or estimate an upper limit?
The spot separation is
D = 2 d Tan(\phi) Cos(\theta), where \phi = ArcSin(Sin(\theta) * n)
D = 2 d Tan(\phi) Cos(\theta), where \phi = ArcSin(Sin(\theta) / n) (<== correction by Manasa's entry)
\theta is the angle of incidence. For a small \theta, D is propotional to \theta.
So If you double the incident angle, the beam separation will be doubled,
while the reflectivity is an even function of the incident angle (i.e. the lowest order is quadratic).
I am not sure until how much larger angle you can use the quadratic function rather than a quartic function.
But thinking about the difficulty you have, it might be worth to try. |
8045
|
Fri Feb 8 21:14:52 2013 |
Manasa | Update | Optics | G&H - AR Reflectivity | Hours of struggle and still no data 
I tried to measure the AR reflectivity and the loss due to flipping of G&H mirrors
With almost no wedge angle, separating the AR reflected beam from the HR reflected beam seems to need more tricks.

The separation between the 2 reflected rays is expected 0.8mm. After using a lens along the incident beam, this distance was still not enough to be separable by an iris.
The first trick: I could find a prism and tried to refract the beams at the edge of the prism...but the edges weren't that sharp to separate the beams (Infact I thought an axicon would do the job better..but I think we don't have any of those).
Next from the bag of tricks: I installed a camera to see if the spots can actually be resolved.
The camera image shows the 2 sets of focal spots; bright set to the left corresponding to HR reflected beam and the other from the AR surface. I expect the ghost images to arise from the 15 arcsec wedge of the mirror. I tried to mask one of the sets using a razor blade to see if I can separate them and get some data using a PD. But, it so turns out that even the blade edge is not sharp enough to separate them.
If there are any more intelligent ideas...go ahead and suggest!

|
8044
|
Fri Feb 8 20:27:56 2013 |
Koji | Update | RF System | MC REFL Photodiode transimpedance | The comment itself was added by me.
The difference between the previous and new measurements should be described by Riju.
In the entry 7984, the description has several PDs mixed up. The measurement was done with the MCREFL PD.
But the DC transimpedance of the thorlabs PD (5e3) was used, according to the text.
I first wonder if this is only a mistake not in the calculation but only in the elog due to a sloppy copy-and-paste.
But the resulting shot-noise-intercept current was 50uA, which is way too small
compared with a realistic value of 0.1~1mA. I have never seen such a good value with
C30642 at the resonant freq ~30MHz. That's why I said "hard to believe". I guessed this wrong
DC transimpedance was actually used for the calculation.
You may wonder why this 50uA is unreasonable number.
Basically this is just my feeling and probably is same as Rana's feeling.
But "my feeling" can't be a scientific explanation. Here is some estimation.
Looking at my note in 2010:
https://wiki-40m.ligo.caltech.edu/40m_Library (Comparisons of the PD circuits by KA)
The expected shot noise intercept current (idc) is
idc = 2 kB T / (e Rres),
where Rres is the impedance of the resonant circuit at the resonant freq.
This Rres is expressed as
Rres = 1/(4 pi^2 fres^2 Cd^2 Rs),
where Cd and Rs are the capacitance and series resistance of the diode.
If we input realistic numbers,
Cd = 100pF
Rs = 10 Ohm
fres = 30MHz
We obtain, Rres ~ 300Ohm, and idc = 0.2mA
In other words, Rs needs to be 2~3Ohm in order to have idc = 50uA.
This is too small from the previous measurements.
Test Results for C30642 LSC Diode Elements by Rich Abbott
|
8043
|
Fri Feb 8 20:05:15 2013 |
Jenne | Update | Locking | PRMI work | I fixed up the POP path so that there is no clipping, so that Yuta can take a cavity mode scan. |
8042
|
Fri Feb 8 19:39:02 2013 |
Koji | Update | Locking | PRMI work | It seems that the cavity trans looks much better than before. Cool.
At least the optical gain is ~x5 of the previous value. This means what we did was something good.
Looking forward to seeing the further analysis of the caivty... |
8041
|
Fri Feb 8 19:29:44 2013 |
yuta | Summary | General | arbcav of half PRC with flipped PR2 | We need expected finesse and g-factor to compare with mode-scan measurement. Can you give us the g-factor of the half-PRC and what losses did you assumed to calculate the finesse?
Also, flipped PR2 should have RoC of - R_HR * n_sub (minus measured RoC of HR surface multiplied by the substrate refractive index) because of the flipping.
According to Jenne dictionary, HR curvature measured from HR side is;
PRM: -122.1 m
PR2: -706 m
PR3: - 700 m
TM in front of BS: -581 m
Please use these values to calculate expected g-factor so that we don't get confused.
Quote: |
Arbcav with half PRC (flat temporary mirror in front of BS), PR2 RoC = 600m, PR3 RoC = -600m:
|
|
8040
|
Fri Feb 8 18:23:32 2013 |
Jamie | Summary | General | arbcav of half PRC with flipped PR2 | Arbcav with half PRC (flat temporary mirror in front of BS), PR2 RoC = 600m, PR3 RoC = -600m:
 
NOTE: this does NOT include the affect of the PR2 substrate in the cavity. Arbcav does not handle that. It would have to be modified to accept arbitrary ABCD matrices.
NOTE: I added to the mode plot the frequency separation of the first HOMs from the carrier (\omega_{10/01}), in units of carrier FSR. |
8039
|
Fri Feb 8 17:41:34 2013 |
Jenne | Update | Locking | PRMI work |
[Yuta, Jenne]
After much tweaking of the alignment using TT1, TT2 and PRM sliders, we were able to get a TEM00 mode locked with the half PRC!
PRCL gain is -0.010
FM4, 5 are always on. FM2,3,6 (boosts and stack res-gains) are triggered to come on after the cavity is locked.
We see a little clipping of POPDC, even though there are 2 BSs in the beam path, to dump 50% and then 67% of the beam. But it's not so much that we can't align.
REFLDC goes from 28.5 to 24.5, so we don't have great visibility.
Please watch our awesome video of the cavity, where we demonstrate that the half cavity is stable:
The cavity is flashing for the 1st 15 sec, then locks. Upper right is REFL, Lower right is POP, Upper left is back of the Faraday, Lower left is MC2F. Note that we definitely see some not so beautiful modes flashing, but most of that is due to the half cavity length and thus greater degeneracy of modes. Jamie is posting a HOM plot presently.
BEAM MOTION:
The beam is moving way more than it should be. Right now the PRM oplev is not coming out of the vacuum, since the flat test mirror mount is obstructing it. However, as we saw with other half-cavity tests, turning on the PRM oplev helps, but does not completely eliminate the beam motion. We should consider putting oplevs on one of the passive TTs, at least temporarily, so we know what kind of motion is coming from where. |
8038
|
Fri Feb 8 17:15:56 2013 |
Jenne | Update | RF System | MC REFL Photodiode transimpedance | This measurement was done already about a week ago, in elog 7984. Can you please describe why the numbers for the last measurement were not believable, and what was done differently this time? |
8037
|
Fri Feb 8 15:53:48 2013 |
Jenne | Update | Locking | PRMI work |
Quote: |
I completely agree with Koji. We definitely should have locked the half PRC first. We were all set up for that.
|
I reminded Jamie this morning that we were not, in fact, set up yesterday for a half PRC. I had extracted what was the flat test mirror, to put in as PR2. The test mirror was the better of the 2 G&Hs that we had measurements for, so I had used it as the flat test mirror, but then also wanted it to be the more permanent PR2. After doing the PR2 flip, the IFO was naturally all aligned for PRMI, which is part of why we just did that.
Anyhow, Jamie used his tallness to put the other measured G&H mirror into the mount, and put that in front of the BS. He aligned things such that he saw fringes in the half PRC.
I then aligned POP onto the camera, and onto the PD. Yuta is confirming that we're maximally on the REFL PDs.
We're starting locking in 5 min. |
8036
|
Fri Feb 8 12:43:26 2013 |
yuta | Update | Computers | videocapture.py now supports movie capturing | I updated /opt/rtcds/caltech/c1/scripts/general/videoscripts.py so that it supports movie capturing. It saves captured images (bmp) and movies (mp4) in /users/sensoray/SensorayCaptures/ directory.
I also updated /opt/rtcds/caltech/c1/scripts/pylibs/pyndslib.py because /usr/bin/lalapps_tconvert is not working and now /usr/bin/tconvert works.
However, tconvert doesn't run on ottavia, so I need Jamie to fix it.
videocapture.py -h:
Usage:
videocapture.py [cameraname] [options]
Example usage:
videocapture.py MC2F -s 320x240 -t off
(Camptures image of MC2F with the size of 320x240, without timestamp on the image. MUST RUN ON PIANOSA!)
videocapture.py AS -m 10
(Camptures 10 sec movie of AS with the size of 720x480. MUST RUN ON PIANOSA!)
Options:
-h, --help show this help message and exit
-s SIZE specify image size [default: 720x480]
-t TIMESTAMP_ONOFF timestamp on or off [default: on]
-m MOVLENGTH specity movie length (in sec; takes movie if specified) [default: 0] |
8035
|
Fri Feb 8 12:42:45 2013 |
nicolas | Summary | General | PRC/arm mode matching calculations |
Quote: |
The main issue is that flipping PR3 induces considerable astigmatism.
|
Yes, at 45degrees PR3 will only have a curvature of about 850m for the vertical mode of the beam, apparently not enough to stabilize the cavity. |
8034
|
Fri Feb 8 12:39:32 2013 |
yuta | Update | Locking | PRMI work | Half-PRC at this time already have two changes from the previous half-PRC; PR2 replaced/flipped and different TM before BS.
PRMI has only one change from the previous PRMI; PR2 replaced/flipped.
This is why I wanted to try PRMI first. But we now recognized that MI alignment (including REFL and AS alignment) is tough without using the arms, I agree that we should try half-PRC first.
I don't exactly know what the situation in the Jamie's calculation, but to make the optical path length the same before and after flipping, PR2 holder have to move about n*t, where n is the substrate refractive index and t is the thickness of the mirror, towards PRM/PR3.
Quote: |
The first rule of debugging is to only make one change at a time.
Also, we never talked about moving PR2 to adjust optical path length,
|
|
8033
|
Fri Feb 8 11:07:07 2013 |
Jamie | Summary | General | PRC/arm mode matching calculations |
Quote: |
I would guess that either flipping PR2 or PR3 would give nearly the same effect (g = 0.9) and that flipping both makes it even more stable (smaller g). But what we really need is to see the cavity scan / HOM resonance plot to compare the cases.
The difference of 0.5% in mode-matching is not a strong motivation to make a choice, but sensitivity to accidental HOM resonance of either the carrier or f1 or f2 sidebands would be. Should also check for 2*f2 and 2*f1 resonances since our modulation depth may be as high as 0.3. Accidental 2f resonance may disturb the 3f error signals.
|
You would guess, and I would have guessed too, but the calculations tell the story. Flipping both does not increase the stability. The main issue is that flipping PR3 induces considerable astigmatism. This is why flipping PR3 alone does not make the cavity stable. I will do some simple calculations today that will demonstrate this effect.
But again, we should only change one thing at a time and understand that before moving on. Given that the calculations show that flipping only PR2 should alone have a positive affect, we should do just that first, and verify that we understand what's going on, before we move on to making more changes.
I will try to make some more arbcav runs as well, for just the flipped PR2. |
8032
|
Fri Feb 8 11:01:18 2013 |
Jamie | Update | Locking | PRMI work | I completely agree with Koji. We definitely should have locked the half PRC first. We were all set up for that. Why go through all this work to align MICH when we haven't confirmed with the half PRC that the flipping is helping us? The first rule of debugging is to only make one change at a time. We have measurements from the half PRC, so we could have made a direct comparison with those to see how things have changed. If we jump the gun we're going to end up wasting more time when we have to back-track.
Also, we never talked about moving PR2 to adjust optical path length, although I can understand why we would think that should be done. My calculations were all done assuming the free-space separation between PRM/PR2 and PR2/PR3 were unchanged. It's possible changing the position is better, but again, it's more work and it changes multiple things at one. I can redo my calculations for this new scenario, but we need to update our drawings with this new configuration. Please note precisely where PR2 has moved to.
We should have just flipped PR2 and that's it. Then we could have run the exact same measurements we had previously. Only then, once we understood this new simple cavity, should we have done further adjustments. |
8031
|
Fri Feb 8 02:38:04 2013 |
Koji | Update | Locking | PRMI work | I feel it's too hasty to use the PRMI.
I support the idea of the half-PRC test, to make an apple-to-apple comparison.
Make haste slowly. |
8030
|
Fri Feb 8 02:12:14 2013 |
Jenne | Update | Locking | PRMI work | [Jenne, Yuta]
Lots of work, no solid conclusions yet. In-vac, we aligned MICH and the PRM. Out of vac, we got beam on AS and REFL paths. We can lock MICH, but we're not as happy with PRCL.
In-vac alignment:
To get the beam centered on TT2 in yaw, Koji helped us out and moved TT1 with the sliders a little bit. Then to get the beam centered on PRM and PR2, Koji moved the TT2 sliders a little bit.
Yuta and I then moved PR2 forward a few mm, to keep the optical path length of the PRC approximately (within ~1mm, hopefully) the same as always. After my PR2 optic swapping earlier, the pitch alignment was no longer good. I loosened the screws holding the wire clamp to the optic holder, and tapped it back and forth until the alignment was good. Of course, the screw-tightening / pitch-checking is a stochastic process, but eventually we got it. A small amount of yaw adjustment by twisting the PR2 TT was also done, but not much was needed.
Beam was a little off in pitch at ITMY, so Yuta poked the top of PR3, and that one single poke was perfect, and the beam was very nicely centered on the ITMY target. Beam was getting through BS target just fine. We checked at ITMX, and the beam looked pretty centered, although we didn't put in a target. We didn't do anything to BS while we were in-vac, since it was already good.
We aligned the ITMs so that their beams were retroreflecting back to the BS. After this, we saw nice MICH fringes.
We aligned the PRM so that its beam was retroreflecting.
We checked that we were getting REFL and AS beams out of the vacuum, which we were (a small amount of adjustment was done to AS path steering mirrors).
AS table alignment:
We did a bit of tweaking of the REFL path, and lots of small stuff to the AS path.
The AS beam was coming out of vac at a slightly different place in yaw, so we moved the first out of vac AS steering mirror so the beam hit the center, rather than ~1/3 of the way to the edge. We then aligned the beam through the lens, to the camera, and to AS55. Most significantly, we removed the BS that was just before AS55. This was sending beam to a dump, but it is in place to send beam over to AS110, once we get back to real locking. We measured ~30 microwatts of power going to the AS55 PD, while MICH fringes were fringing.
The REFL path didn't need much, although we had never been going through the center of the HWP and PBS that are used to reduce the power before going to the PDs, so we translated them a millimeter or two.
We see signal on dataviewer for all of the channels that we're interested in....AS55 I&Q, ASDC, REFL11 I&Q, REFLDC (which comes from REFL55).
Locking:
Locking MICH was very easy, after we rotated the phase of AS55 to get all the good MICH signal in the Q phase. Part of the criteria for this was that the AS55_Q_ERR signal should cross zero when ASDC went to 0. This was done very coarsely, so we need to do it properly, but it was enough to get us locked. We changed the phase from 24.5 to 90 deg.
PRCL has been more of a challenge, although we're still working on it.
On the back face of the Faraday, we see the michelson fringes, but they are not getting through the Faraday's aperture. This implies that we have a poorly aligned michelson, in that the interference between the returning beams from the ITMs is happening at a different place than the original beam splitting. Yuta is working on getting a better MICH right now. EDIT, 10 minutes later.... This seems to be fixed, and the MICH fringes enter the back aperture of the FI, but there is still the PRM refl problem (next paragraph).
Also, when we get the most bright REFL beam, we see that there is some very obvious clipping in the back of the Faraday aperture, and this is matched by a clipped-looking REFL beam on the AS table. We must understand what we have done wrong, such that when the beam is actually going through the Faraday, we see a much dimmer beam. It's possible that there is some clipping happening at that time with the in-vac REFL path....we need to check this. It's not a clipping problem on the AS table - I checked, and the beams are still reasonably well centered on all of the mirrors.
We think that the MICH / REFL beam problems may be that the input pointing is close, but not perfect. We have not confirmed today that the beam is centered on ETMY. We should do this as part of our final alignment procedure before putting on doors.
Plans for tomorrow:
Get POP aligned, especially the camera, so we can see what our intracavity mode really looks like in the PRC. This is probably (in part, at least) due to our having moved PR2 around, so the transmitted beams aren't in exactly the same place.
We think that it's more useful in the short term to check out the PRC, and since the clipping problem with the REFL beam is likely an imperfect input pointing, we want to use the other measured G&H mirror, and do another half-PRC test, with the test mirror in front of the BS. This requires much less perfection in the input pointing, so it should be very quick to set up.
Confirm that PRM oplev is still aligned (turn laser back on first).
Plans for next week:
Perfect the input pointing, by checking the beam position at ETMY. Recheck all corner alignment.
Try again locking PRMI in air. First, confirm ITM and BS oplevs are all aligned. |
8029
|
Fri Feb 8 00:23:33 2013 |
rana | Summary | General | PRC/arm mode matching calculations |
I would guess that either flipping PR2 or PR3 would give nearly the same effect (g = 0.9) and that flipping both makes it even more stable (smaller g). But what we really need is to see the cavity scan / HOM resonance plot to compare the cases.
The difference of 0.5% in mode-matching is not a strong motivation to make a choice, but sensitivity to accidental HOM resonance of either the carrier or f1 or f2 sidebands would be. Should also check for 2*f2 and 2*f1 resonances since our modulation depth may be as high as 0.3. Accidental 2f resonance may disturb the 3f error signals. |
8028
|
Thu Feb 7 19:25:22 2013 |
yuta | Update | CDS | C1ALS filters reloaded | Filters for C1ALS were all gone. So, I copied /opt/rtcds/caltech/c1/chans/C1GCV.txt and renamed it as C1ALS.txt.
I also fixed links in the medm screens; C1ALS.adl and C1ALS_COMPACT.adl.
I'm not sure what happened to C1SC{X,Y} screens.
Quote: |
I decided to rename the c1gcv model to be c1als. This is in an ongoing effort to rename all the ALS stuff as ALS, and get rid of the various GC{V,X,Y} named stuff.
(...snip...)
The above has been done. Still todo:
- FIX SCRIPTS! There are almost certainly scripts that point to GC{V,X,Y} channels. Those will have to be fixed as we come across them.
- Fix the c1sc{x,y}/master/C1SC{X,Y}_GC{X,Y}_SLOW.adl screens. I need to figure out a more consistent place for those screens.
- Fix the C1ALS_COMPACT screen
- ???
|
|
8027
|
Thu Feb 7 19:24:57 2013 |
Riju | Update | | Photodiode transimpedance | Summary: Measurement and plot of shot-noise-intercept-current for MC REFL PD.
Motivation:It is to measure the shot noise intercept current for MC REFL PD.
Result: The final plot is attached here. The plot suggests that the value of shot-noise-intercept current is 1.9mA
Discussion:
The plot is for the measured data of Noise voltage (V/sqrt(Hz)) vs DCcurrent(A). The fitted plot to this measured data follows the noise equation
Vnoise = gdet* sqrt[ 2e (iDC+idet)] , where gdet= transimpedance of the PD in RF region ~600
To get an approximate idea of the shot noise intercept current, we may follow the same procedure described in 7946
In the present case minimum noise value is 1.46e-08 V/sqrt(Hz)
Therefore dark current(in2) ~dark noise voltage/RF transimpedance ~25pA/sqrt(Hz)
Therefore the approximate shot noise intercept current value is (25/18)^2 ~ 1.92mA, which matches well to the fitted value.
|
Attachment 1: reflshotnoise.pdf
|
|
8026
|
Thu Feb 7 17:24:13 2013 |
Steve | Update | SAFETY | fire extinguishers checked | The fire department weighted and pressure checked our units today. Surprisingly they found one powder filled can. We can only use HALON gas in the lab.
|
8025
|
Thu Feb 7 17:10:11 2013 |
Koji | Summary | General | PRC/arm mode matching calculations |
Quote: |
I left out the current situation (PR2/3 with -600 RoC) and the case where only PR3 is flipped, since those are both unstable according to a la mode.
|
This surprises me. I am curious to know the reason why we can't make the cavity stable by flipping the PR3 as PR3 was supposed to have more lensing effect than PR2 according to my statement. |
8024
|
Thu Feb 7 15:46:42 2013 |
Jenne | Update | Locking | PR2 flipped | More correctly, a different G&H mirror (which we have a phase map for) was put into the PR2 TT, backwards.
Order of operations:
* Retrieve flat test G&H from BS chamber. Put 4th dog clamp back on BS optic's base.
* Remove flat G&H from the DLC mount, put the original BS that was in that mount back. Notes: That BS had been stored in the G&H's clean optic box. The DLC mount is engraved with the info for that BS, so it makes sense to put it back. The DLC mount with BS is now back in a clean storage box.
* Remove PR2 TT from ITMX chamber.
* Remove suspension mounting block from TT frame, lay out flat, magnets up, on lint-free cloth on top of foil.
* Remove former PR2 G&H optic.
* Put what was the flat G&H test optic into the PR2 optic holder, with AR surface at the front.
* Put PR2 suspension block back onto TT frame.
* Put PR2 assembly back in the chamber, solidly against the placement reference blocks that Evan put in last Thursday.
* Close up, clean up, put labels on all the boxes so we know what optic is where.
Why the switcho-changeo? We have a phase map for the G&H that is the new PR2, and a measured RoC of -706m, surface rms of 8.7nm. Now, we can measure the former PR2 and see how it compares to our estimate of the RoC from the cavity measurements we've taken recently. |
8023
|
Thu Feb 7 14:10:25 2013 |
Manasa | Update | Optics | LaserOptik - AR Reflectivity - Bad data | Reflectivity of AR surface of LaserOptik (SN6)

The first step measurements of R for AR surface. I am not convinced with the data....because the power meter is a lame detector for this measurement.
I'm repeating the measurements again with PDs. But below is the log R plot for AR surface.
R percentage
6000ppm @ 42 deg
3560ppm @ 44 deg
7880ppm @ 46 deg
4690ppm @ 48 deg

|
8022
|
Thu Feb 7 12:56:18 2013 |
Jamie | Summary | General | PRC/arm mode matching calculations | NOTE: There was a small bug in my initial calculation. The plots and numbers have been updated with the fixed values. The conclusion remains the same.
Using Nic's a la mode mode matching program, I've calculated the PRC mode and g-parameter for various PR2/3 scenarios. I then looked at the overlap of the resultant PRC eigenmodes with the ARM eigenmode. Here are the results:
NOTE: each optical element below (PR2, ITM, etc.) is represented by a compound M matrix. The z axis in these plots is actually just the free space propagation between the elements, not the overall optical path length.
ARM
This is the ARM mode I used for all comparisons:
 
|
tangential |
sagittal |
gouy shift, one-way |
55.63 |
55.63 |
g (from gouy) |
0.303 |
0.303 |
g (product of individual mirror g) |
0.303 |
0.303 |
PRC, nominal design (flat PR2/3)
This is the nominal "as designed" PRC, with flat PR2/3 folding mirrors.
 
|
tangential |
sagittal |
gouy shift, one-way |
14.05 |
14.05 |
g (from gouy) |
0.941 |
0.941 |
g (product of individual mirror g) |
0.942 |
0.942 |
ARM mode matching: 0.9998
PRC, both PR2/3 flipped
This assumes both PR2 and PR3 have a RoC of -600 when not flipped, and includes the affect of propagation through the substrates.
 
|
tangential |
sagittal |
gouy shift, one-way |
19.76 |
18.45 |
g (from gouy) |
0.886 |
0.900 |
g (product of individual mirror g) |
0.888 |
0.902 |
ARM mode matching: 0.9806
PRC, only PR2 flipped
In this case we only flip PR2 and leave PR3 with it's bad -600 RoC:
 
|
tangential |
sagittal |
gouy shift, one-way |
18.37 |
18.31 |
g (from gouy) |
0.901 |
0.901 |
g (product of individual mirror g) |
0.903 |
0.903 |
ARM mode matching: 0.9859
Discussion
I left out the current situation (PR2/3 with -600 RoC) and the case where only PR3 is flipped, since those are both unstable according to a la mode.
I guess the main take away is that we get slightly better PRC stability and mode matching to the arms by only flipping PR2. |
8021
|
Thu Feb 7 10:35:35 2013 |
yuta | Update | General | Store optics in respective cabinets | I'm not the one who opened the ITMX table yesterday, but thanks for reminding me.
I put POP DC oscilloscope and its cables back.
Also, I relocked PMC and MC. It was unlocked since last night. |
8020
|
Thu Feb 7 09:03:54 2013 |
Manasa | Update | General | Store optics in respective cabinets |
@Yuta
The ITMX table has been left open since yesterday. I am disconnecting your oscilloscope and closing the table.
To whomsoever it may concern...
I found about half a dozen new cvi optics (beam splitters, waveplates and lenses) lying around on the SP table.
Please store optics back in their respective cabinets if you are not using them immediately. Somebody might be looking around to use them.
|
8019
|
Wed Feb 6 22:39:23 2013 |
Jamie | Update | General | PRC/arm mode matching with flipped PR2/PR3: coming soon | I intended to post a long analysis of the PRC/arm mode matching for the various TT situations using Nic's a la mode mode matching program, but I seem to have encountered what I think might be a bug. I'll talk to Nic about it first thing in the AM. Once the issue is resolved I should be able to post the full analysis fairly quickly. Sorry about the delay. |
|