Jenne | Update | SUS | MC2 is being a little wild...WFS to blame |
Mirko and Den are measuring MC_F, which they will report about later, but I noticed that MC2 is totally crazy right now. It shouldn't matter that they are doing things (like unplugging the feedback to the PSL's PZT), because we actuate on the laser, not on the MC. I disabled the MC autolocker before they started working.
Anyhow, somehow MC2 got kicked up (whatever, that happens), but it won't re-damp. I think it's the WFS. The yaw output from the WFS is truely crazy.
I have disabled the WFS output / ASC input on the MC SUS screens, and MC2 was then able to damp. My disabling only the MC2 WFS input at first kicked up MC1 and 3, so I disabled all of the WFS stuff, and all 3 MC mirrors are again happy.
SURESH: FIX ME! (signed, The WFS)

|
5865
|
Thu Nov 10 19:41:24 2011 |
Jenne | Update | SUS | Musings on SUS dewhitening, and MC ELP28's |
The following will be a stream-of-consciousness, approximately chronological story of my last hour or so of looking at screens....
In the old OAF days, we used to bypass the analog dewhitening in the coil driver path, using the XYCOMS. See, ex. elog 2548.
I began to wonder if we needed to do the same thing now. I checked several optics, to see how the switching works.
For the whitening on the OSEM sensor input, FM1 is linked to the Contec binary I/O. FM1 is the inverse whitening filter. Turn it on, and the analog whitening is on (bit in the binary I/O screen turns red). Turn it off, and the analog whitening is bypassed (bit in the binary I/O screen turns gray). Good. Makes sense. Either way, the net transfer function is flat.
The dewhitening is not so simple. In FM9 of the Coil Output filter bank, we have "SimDW", and in FM10, we have "InvDW". Clicking SimDW on makes the bit in the binary I/O screen gray (off?), while clicking it off makes it red (on?). Clicking InvDW does nothing to the I/O bits. So. I think that for dewhitening, the InvDW is always supposed to be on, and you either have Simulated DW, or analog DW enabled, so that either way your transfer function is flat. Fine. I don't know why we don't just tie the analog to the InvDW filter module, and delete the SimDW, but I'm sure there's a reason.
All optics have this setup, except MC1 and MC3. They don't have the SimDW or InvDW filter modules. Instead, in FM9 (which on all the other suspensions is SimDW, and controls the binary I/O) there is a 28Hz Elliptic Low Pass filter. The only thing I can find about these is elog 1405 where Rana talks about implementing ELP28's in MC2. But right now there is no ELP in the MC2 coil output filters. So, if Rana's old elog is to be believed, we need to fix up the ELP28 situation. But that elog was from a long time ago, so maybe things are different now? If MC1 and MC3 need the SimDW and InvDW (why wouldn't they?) then the ELP28 needs to move to another filter module. Because right now, when I click the ELP28's on and off, it changes bits in the binary I/O. Which I don't think it should. Maybe. I don't really know.
Okay. So. Now we know where everything is, and which buttons do what. Maybe not why, but at least what.
In the old world, Rob had lots and lots of trouble (elog 2027) with locking when the analog dewhitening was bypassed. But right now, I think that all of the analog dewhitening filters are bypassed, for every single optic we have. So. Which way do we want things? What's the new game plan. What's going on??
\end{stream-of-consciousness} |
5873
|
Fri Nov 11 13:26:24 2011 |
jamie | Update | SUS | Musings on SUS dewhitening, and MC ELP28's |
Quote: |
For the whitening on the OSEM sensor input, FM1 is linked to the Contec binary I/O. FM1 is the inverse whitening filter. Turn it on, and the analog whitening is on (bit in the binary I/O screen turns red). Turn it off, and the analog whitening is bypassed (bit in the binary I/O screen turns gray). Good. Makes sense. Either way, the net transfer function is flat.
The dewhitening is not so simple. In FM9 of the Coil Output filter bank, we have "SimDW", and in FM10, we have "InvDW". Clicking SimDW on makes the bit in the binary I/O screen gray (off?), while clicking it off makes it red (on?). Clicking InvDW does nothing to the I/O bits. So. I think that for dewhitening, the InvDW is always supposed to be on, and you either have Simulated DW, or analog DW enabled, so that either way your transfer function is flat. Fine. I don't know why we don't just tie the analog to the InvDW filter module, and delete the SimDW, but I'm sure there's a reason.
|
The input/whitening filters used to be in a similarly confused state as the output filters, but they have been corrected. There might have been a reason for this setup in the past, but it's not what we should be doing now. The output filters all need to be fixed. We just haven't gotten to it yet.
As with the inputs, all output filters should be set up so that the full output transfer function is always flat, no matter what state it's in. The digital anti-dewhitening ("InvDW") and analog dewhitening should always be engaged and disengaged simultaneously. The "SimDW" should just be removed.
This is on my list of things to do. |
5877
|
Fri Nov 11 21:09:30 2011 |
Suresh | Update | SUS | MC2 is being a little wild...WFS to blame |
Quote: |
Mirko and Den are measuring MC_F, which they will report about later, but I noticed that MC2 is totally crazy right now. It shouldn't matter that they are doing things (like unplugging the feedback to the PSL's PZT), because we actuate on the laser, not on the MC. I disabled the MC autolocker before they started working.
Anyhow, somehow MC2 got kicked up (whatever, that happens), but it won't re-damp. I think it's the WFS. The yaw output from the WFS is truely crazy.
I have disabled the WFS output / ASC input on the MC SUS screens, and MC2 was then able to damp. My disabling only the MC2 WFS input at first kicked up MC1 and 3, so I disabled all of the WFS stuff, and all 3 MC mirrors are again happy.
SURESH: FIX ME! (signed, The WFS)

|
The Problem
Turning off the WFS servo loops usually should be done using the 'mcwfsoff' script. The script takes care of switching off the integrators and Clears the History.
'mcdown' and 'mcup' scripts run the 'mcwfsoff' and 'mcwfson' scripts so when the MC unlocks the WFS servos are shutdown and restarted properly. However if the MC autolocker script is suspended by pressing the Enable/Disable switch in the LOCKMC screen and then the MC unlocks, it results in the WFS servo integrators accumulating large values. If these values are passed through the ASC filter banks the optic will get a pretty huge kick.
The Solution
I have added some indicators which will let us know if the WFS Servo Filter outputs are larger than +/-1000. When engaging the WFS loops the user has to take care to Clear History in the servo filter banks if these indicators are steadily Red. before engaging the WFS Servo loops ensure that the servo filter outputs are zeroes.
Koji and I discussed whether it would be useful to run the 'mcwfsoff' script when the Disable button is pressed in the autolocker. His recommendation is that we should keep the autolocker script simple and that user has to be cautious when switching on the WFS servos and when directing the ASC outputs to the suspensions.

|
5909
|
Wed Nov 16 10:25:57 2011 |
steve | Update | SUS | PRM damping restored |
The PRM lost damping about a day ago. It was restored. |
5927
|
Thu Nov 17 15:19:06 2011 |
steve | Update | SUS | Ti spring plunger to hold OSEM is not affortable |
Our existing 300 series SS plungers from McMastercar #8476A43 are silver plated as Atm2 shows.
Problems: 1, they become magnetized after years being close to the magnets
2, they oxidize by time so it is hard to turn them
I looked around to replace them.
Titanium body, nose and beryllium copper spring. None magnetic for UHV enviorment.
Can be made in 7 weeks at an UNREASONABLE $169.00 ea at quantity of 50 |
Attachment 1: 20111116111042405.pdf
|
|
Attachment 2: P1080216.JPG
|
|
5974
|
Tue Nov 22 00:19:10 2011 |
kiwamu | Update | SUS | c1auxey hadware rebooted |
I found that the slow machine c1auxey, which controls and monitoring the ETMY suspension things, were not responding.
The machine responded to ping but I wasn't able to telnet to it.
I went down there and power-cycled it by keying the power of the VME rack, and then it came back and seems working properly.
I have no idea why it ran into such condition. |
5982
|
Tue Nov 22 23:06:13 2011 |
kiwamu | Update | SUS | MC watchdogs |
[Rana / Mirko / Kiwamu]
The watchdogs on the MC suspensions are not working.
Switching off the watchdogs doesn't stop feeding signals to the suspensions.
For tonight, we will leave the controller of the MC suspensions switched off so that the computer won't smash the optics accidentally. |
6007
|
Fri Nov 25 18:45:31 2011 |
Den, Rana | Summary | SUS | Excess Noise in Digital Filtering |
We are now trying to understand why the coherence between SUS-X_SUSPOS_IN1 and SUS-X_SUSPOS_OUT is lost below 1 Hz for X = MC1, MC2, MC3, BS, ITMX, ITMY, ETMX, ETMY, SRM. It is OKEY only for PRM but the different filteres are used there. For PRM - 30:0.0 and Bounce Roll, for all others - 30:0.0 and Cheby. The transfer functions between these two signals plotted in foton and fft tools are also not the same.
If we switch off all the filters between these 2 signals, than the coherence is one. If one of the filters is switched on, everything is also fine. But if there are several present, than they filter the signal in unexpected way.
Moreover it seems that the coherence is dependent on the input signal. The coherence is better with local dumping than without. |
Attachment 1: FiltNoise.png
|
|
6008
|
Fri Nov 25 19:45:36 2011 |
Mirco, Den | Summary | SUS | Excess Noise in Digital Filtering |
Quote: |
We are now trying to understand why the coherence between SUS-X_SUSPOS_IN1 and SUS-X_SUSPOS_OUT is lost below 1 Hz for X = MC1, MC2, MC3, BS, ITMX, ITMY, ETMX, ETMY, SRM. It is OKEY only for PRM but the different filteres are used there. For PRM - 30:0.0 and Bounce Roll, for all others - 30:0.0 and Cheby. The transfer functions between these two signals plotted in foton and fft tools are also not the same.
If we switch off all the filters between these 2 signals, than the coherence is one. If one of the filters is switched on, everything is also fine. But if there are several present, than they filter the signal in unexpected way.
Moreover it seems that the coherence is dependent on the input signal. The coherence is better with local dumping than without.
|
We have done the following on the c1sus and c1lsc computers : provided excitation, let the signal pass through filters 30:0.0 and Cheby and plotted the coherence between in and out signals.
c1sus computer - coherence is corrupted
c1lsc computer - coherence is not corrupted |
Attachment 1: sus_coh-crop.pdf
|
|
Attachment 2: lsc_coh-crop.pdf
|
|
6010
|
Fri Nov 25 20:41:48 2011 |
rana | Update | SUS | MC watchdogs |
It seems as if someone was looking into this on Wednesday, but as there's no elog, I think probably not.
Tonight we noticed that, in fact, the watchdogs don't work for any of the corner optics (I confirmed that they do work for the ETMs).
Whether the switch for the coil drivers is enabled or disabled, the voltage monitor on the coil drivers responds to the digital signals.
I tried restarting the c1susaux process, hitting reset on the crate, and also keying the crate. The +5V light on the front of the crate is flickering somewhat, but I'm not sure if this is new or not since the power outage. The next step is to track the Xycom signal from the card over to the coil driver to find where the signal is failing to happen.
Since its not working for any of the corner optics, I suspect the crate and not the cards. If that's the issue this will be a painful fix. We are sort of assuming that this is due to the power outage, but in fact, I cannot tell when the last time was that someone rigorously verified the working of these switches. [
I][B]We had better get ready for upgrading our SLOW controls, Jamie.[/B][/I]
Quote:
|
[Rana / Mirko / Kiwamu]
The watchdogs on the MC suspensions are not working.
Switching off the watchdogs doesn't stop feeding signals to the suspensions.
For tonight, we will leave the controller of the MC suspensions switched off so that the computer won't smash the optics accidentally.
|
|
6014
|
Sat Nov 26 02:15:42 2011 |
Mirko | Update | SUS | Not adaptive, still cool |
[Rana, Mirko]
I tried out the virtual pendulum idea today. The idea is to compensate the physical pendulum via the control system, and then add a virtual pendulum formed in the control system. We know the actuator TF from p. 5900 and apply its inverse to the C1:SUS-MC?_SUSPOS filters. Also we add an pendulum Q=3 with a resonance frequency of 0.1Hz to the POS control loops.
The result is pretty awesome!
1. Black: Standard config. Wfs on. New Cheby filter in place ( p. 6031 )
2. Red: With virtual pendulum. Extra eliptic LP filter @ 2.5Hz

Filter shape:

This is stable for 5-10minutes, at which point it falls out of lock, swinging in yaw.
|
Attachment 3: SetupVirtualPendulumV2.png
|
|
6021
|
Mon Nov 28 10:54:40 2011 |
rana | Update | SUS | F2A filter for MC |
Our approach to making the F2A or F2P filters for the MC is to use the measured resonant frequencies and then calculating the appropriate mechanical dimensions of each suspension. This is basically because we don't have optical levers with normal incidence on these optics, but the method should be fine.
To find the formulas, I asked Gaby for her old cheat sheet: Its now in the DCC. Its only for Large optics, but you should be able to reconstruct the right ones for SOS by just changing the parameters. |
6057
|
Thu Dec 1 03:27:39 2011 |
Mirko | Update | SUS | Not adaptive, still cool |
Quote: |
[Rana, Mirko]
I tried out the virtual pendulum idea today. The idea is to compensate the physical pendulum via the control system, and then add a virtual pendulum formed in the control system. We know the actuator TF from p. 5900 and apply its inverse to the C1:SUS-MC?_SUSPOS filters. Also we add an pendulum Q=3 with a resonance frequency of 0.1Hz to the POS control loops.
The result is pretty awesome!
1. Black: Standard config. Wfs on. New Cheby filter in place ( p. 6031 )
2. Red: With virtual pendulum. Extra eliptic LP filter @ 2.5Hz

Filter shape:

This is stable for 5-10minutes, at which point it falls out of lock, swinging in yaw.
|
In the above entry MC_f signal is improved off of resonance by the implementation of the pendulum compensation. It should be checked if this is actually due to the implementation of the virtual pendulum at 0.1Hz. A way to check that might be to implement a simple double LP at 0.1Hz instead and look at the resulting MC_f signal. A projection of the OSEM FB noises with the compensation active might be interesting.
The physical resonance at 1Hz is clearly not compensated correctly, which is probably the reason for the lock losses after a few minutes. It might be a good start to measure the residual resonance with the compensation in place. The filters in bank 7 of C1:SUS-MC?_SUSPOS have both the compensation of the 1Hz resonance( really the inverse actuator TF ) and the virtual pendulum in them. The ‘pure’ compensation can be found in the InvTF module in the C1:OAF-ADAPT_MCL_CORR filter.
The fact that the beam swings in yaw at lock loss indicates that the separation of the DOFs might not be perfect. One should have a look into the yaw and pitch DOFs with the compensation active. |
6060
|
Thu Dec 1 17:33:18 2011 |
kiwamu | Update | SUS | watchdogs fixed |
The watchdogs' issue has been solved and they are now working fine.
It was just because one of the Sorensens had been off.
The Sorensen is the one supplying +5 V in the 1X5 rack.
This +5 V is actually used as a pull-up-current to properly drive the MAX333As (CMOS analog switch) in the coil drivers (D010001).
So this was it.
|
Tonight we noticed that, in fact, the watchdogs don't work for any of the corner optics (I confirmed that they do work for the ETMs).
|
|
6128
|
Sat Dec 17 01:56:16 2011 |
Koji | Summary | SUS | Hysteresis test |
[Koji Kiwamu]
We wonder if the flakiness of MC2 comes from the suspension or not.
To test it, we are shaking all of the suspension biases +/-1.0 with a script.
The script is here:
/users/koji/111216/SUS_hysteresis.sh
For this test, we closed the mechanical shutter before the MC.
Also some amount of misalignment is anticipated.
Don't be surprised if you see nothing is working when you come to the lab in the weekend.
-- EDIT by KI:
I found the ITMY watchdogs tripped around 2:40 AM and then re-engaged it. |
6129
|
Sat Dec 17 03:59:32 2011 |
kiwamu | Update | SUS | Aborted Hysteresis test |
Quote from #6128 |
To test it, we are shaking all of the suspension biases +/-1.0 with a script.
|
The hysteresis test has been aborted.
All of the suspensions have accumulated unexpectedly big DC biases of about 5 from their nominal points.
In fact the ITMX and ITMY mirrors started being stacked to their OSEMs.
The script process has been force-quit and I have restored all the DC biases to their nominal points.
They still look okay: MC can be locked at the 00 mode, DRMI fringe is visible at AS, the green beams are resonating the arm cavities
Need another trial. |
6130
|
Sat Dec 17 11:53:46 2011 |
Zach | Update | SUS | Aborted Hysteresis test |
Do you guys have timestamps for when you started/ended the test? I have been trying to take some long-term RAM data but keep getting foiled by stuff (this test, RTS upgrade, switching of RAMmon channels, etc.)
Quote: |
Quote from #6128 |
To test it, we are shaking all of the suspension biases +/-1.0 with a script.
|
The hysteresis test has been aborted.
All of the suspensions have accumulated unexpectedly big DC biases of about 5 from their nominal points.
In fact the ITMX and ITMY mirrors started being stacked to their OSEMs.
The script process has been force-quit and I have restored all the DC biases to their nominal points.
They still look okay: MC can be locked at the 00 mode, DRMI fringe is visible at AS, the green beams are resonating the arm cavities
Need another trial.
|
|
6131
|
Sat Dec 17 12:41:46 2011 |
Koji | Update | SUS | Aborted Hysteresis test |
The test was from: 2011-12-17 09:48 to 11:49 (UTC).
This corresponds to the period from 2011-12-17 01:48 to 3:49 (PST).
ZK: Thanks |
6132
|
Sun Dec 18 16:16:55 2011 |
kiwamu | Update | SUS | Another trial of Hysteresis test |
Koji has modified the script for the hysteresis measurement.
A new test started from 16:05 PT, Dec 18th and takes a couple of hours to finish the measurement.
Do not touch the suspensions until further notice.
Quote from #6129 |
The hysteresis test has been aborted.
Need another trial.
|
|
6134
|
Sun Dec 18 19:56:00 2011 |
kiwamu | Update | SUS | Another trial of Hysteresis test |
The measurement finished at ~ 21:50 PT.
Quote from #6132 |
A new test started from 16:05 PT, Dec 18th and takes a couple of hours to finish the measurement.
Do not touch the suspensions until further notice.
|
|
6135
|
Sun Dec 18 23:00:22 2011 |
kiwamu | Update | SUS | oplve recenterd |
I have recentered the oplev beams, including BS, ITMs and ETMs. |
6136
|
Mon Dec 19 01:54:35 2011 |
kiwamu | Update | SUS | another trial of hystersis test |
Another hysteresis test has begun at 1:50 PT, Dec/19.
It will finish after 3 or 4 hours. During the measurement the PSL mechanical shutter will be kept closed.
Time record
Start: Dec/19 1:50 PST
End : Dec/19 5:30 PST |
6142
|
Wed Dec 21 14:23:08 2011 |
rana | Configuration | SUS | Hysteresis in suspensions? |
While discussing the suspension hysteresis measurements, Koji, Kiwamu, and I realized that the suspension wire standoff is aluminum, whereas the standoff for the LIGO LOS are using quartz.
Using a soft aluminum standoff is bad. The movement of the suspension will slowly wear the groove and produce opportunities for mechanical upconversion and hysteresis.
In fact, the wire standoff as well as the clamping block on the top should be made of sapphire or ruby to prevent any such wearing issues. Steve is hot on the case.
|
6180
|
Mon Jan 9 08:47:35 2012 |
steve | Update | SUS | ETMX damping restored |
ETMX sus damping restored |
6181
|
Mon Jan 9 13:19:09 2012 |
kiwamu | Update | SUS | ETMX damping restored |
No we can't do that because the c1scx model is not working properly.
If you look into the real time controller screen you will find what I mean.
Quote from #6180
|
ETMX sus damping restored
|
|
6188
|
Thu Jan 12 07:44:21 2012 |
steve | Update | SUS | sapphire wire standoff quote |
On Tue, Dec 20, 2011 at 11:37 PM, Rana Adhikari wrote:
Steve,
We are thinking of replacing a few metal parts in the suspension with sapphire/ruby. We want to replace the standoff (which is Al) with sapphire and also the top plate where the wire is clamped.
For the top, we should make a cutout for a little plate in the existing crossbar. In the cutout would go a little mounting plate. Then the clamping plate (which is now steel) we would also replace with a Sapphire one.
I don't think it matters whether its sapphire or ruby, just has to be very hard.
Can you please get some quotes on the parts?
rana
|
Attachment 1: standoff.PDF
|
|
6194
|
Thu Jan 12 23:19:56 2012 |
Koji | Update | SUS | c1iscex is fine now |
c1iscex is working as before and the optic is damped.
What I checked
1. I went to the X-end rack. I found the io-chassis was turned off.
2. I shutdown c1iscex, turned off, and turned on everything. Again, we did not have any signal from the ADC into c1scx model.
However, I found that c1x01 indicates healthy ADC signals.
This means that the connection between the IOP and the c1scx model was wrong ==> Simulated Plant
3. Burtrestored X'mas eve snapshot. This restored the gains and matrices as well as C1:SCX-SIM_SWITCH
which switches the input between the real ADCs and simulated plant.
4. The signals came back to c1scx. |
6232
|
Fri Jan 27 09:05:41 2012 |
steve | Update | SUS | OSEM locking plunger |
Quote: |
Our existing 300 series SS plungers from McMastercar #8476A43 are silver plated as Atm2 shows.
Problems: 1, they become magnetized after years being close to the magnets
2, they oxidize by time so it is hard to turn them
I looked around to replace them.
Titanium body, nose and beryllium copper spring. None magnetic for UHV enviorment.
Can be made in 7 weeks at an UNREASONABLE $169.00 ea at quantity of 50
|
In order to get a better price from Vlier's Tom Chen I changed Ti body back to SS304L-siver plated and music wire spring. The price is still ~$120 ea. at quantity 50
I will talk to Mike G about modifying the McMaster plunger with a hex nut. |
6233
|
Fri Jan 27 13:13:03 2012 |
Jenne | Update | SUS | ITMs tripped |
Sitting down to start cavity measurements, I found both ITMs tripped. It must have happened a while ago (I didn't bother to check dataviewer trends) because both had rms levels of <5 counts, so they've had a while to sit and quiet down. |
6238
|
Mon Jan 30 23:10:02 2012 |
kiwamu | Update | SUS | drift mon script needs to be fixed |
[Rana / Kiwamu]
We tried to set some parameters for the suspension drift monitor but the old matlab script, which automatically sets the values, didn't run because it uses the old mDV protocol.
The attached link below is a description about the script.
https://wiki-40m.ligo.caltech.edu/Computers_and_Scripts/All_Scripts#Drift
It needs to be fixed or upgraded by pynds. |
6252
|
Fri Feb 3 19:57:26 2012 |
rana | Configuration | SUS | PSL Shutter closed for SUS hysteresis test |
Fri Feb 03 19:57:20 2012
Fri Feb 03 20:25:19 2012 : Aligned all SUS to center their OL beams
Fri Feb 03 20:29:21 2012: Aligned all SUS to make OL_PIT = 0.5 |
6253
|
Fri Feb 3 20:19:38 2012 |
rana | Update | SUS | Oplev QPD Sum Trends are suspicious |
The attached trend shows a problem with the QPD sums.
Why are ETMX and ITMX so much lower than ETMY and ITMY? Are the laser's dying? Or is it the gain inside the QPD? Or the reflectivity of the coatings?
Steve - please check on Monday the laser powers and the ETM/ITM reflectivity for HeNe lasers. Maybe we have to increase the transimpedance gain in the heads. |
Attachment 1: a.png
|
|
6255
|
Fri Feb 3 23:19:22 2012 |
Zach | Update | SUS | OSEM testing begins |
I took one of the spare OSEM satellite amps (schematic) from the cabinet down the Y arm this afternoon to begin testing. I spent most of the day amassing the melange of adapters and connectors I needed to talk to the relic. The most elusive was the über-rare 64-pin IDE connector, for which neither the 40m nor Downs or Bridge had a breakout (despite there being several Phoenix boxes on each electronics rack at the 40m---hmm...). The solution I came up with was to make a breakout cable myself, only there was no 64-pin ribbon. So, I carefully fed a 50-pin and most of a 16-pin ribbon side by side into one push-down connector, and that was that:

I also finally found a 25-pin D-sub breakout just after figuring out the proper pinout for a 25-to-9 adapter, which I thought I was going to have to use. OH WELL.
Science
The first thing I figured I'd do is measure the LED drivers' current noise and see how it compared with LISO. I powered the box up and found that the TO-3 7815 regulator was putting out +20V---bad. I assumed it was broken, so I got another one from Downs and replaced it. Powered it up again and the output was still at +20V (WTF?). My suspicion is that one of the shielding capacitors has failed in some bizarre way, but I didn't have time to check this before I was beckoned to another task. This is where I'll start again next.
Another thing Frank and I noticed as we were figuring out how the driver worked was that the current-specifying resistor of one of the driver stages had not been properly modified along with the others, so it was forcing the feedback loop to rail. This mod was done precariously by adding two perpendicular sandwiched "Radd" resistors on top of the main one, so it's also possible that the ones for this stage had just been knocked off somehow (perhaps by the massive gender-switching ribbon chain hanging down on it). Steve and I noticed that there was a label on the box complaining that some part of the amp for one of the OSEMs wasn't working, but we peeled it off and threw it away because he figured it was outdated.
Anyway, in short, the plan going forward is as follows:
- For this box
- Measure the LED driver and PD transZ amp noises with dummy components
- Compare with LISO to make sure they make sense
- Measure the noise again with an OSEM connected
- Based on the above and more LISO modeling, decide if it's a good idea to replace the LT1125's with OP497's
- Increase the dynamic range by allowing +/-10V output, rather than +/-2V as was needed for old ADCs
- After
- Systematically mirror the changes in all other boxes by switching one out at a time
Comments welcome. |
6256
|
Mon Feb 6 11:07:21 2012 |
steve | Update | SUS | Oplev QPD Sum Trends are suspicious |
Quote: |
The attached trend shows a problem with the QPD sums.
Why are ETMX and ITMX so much lower than ETMY and ITMY? Are the laser's dying? Or is it the gain inside the QPD? Or the reflectivity of the coatings?
Steve - please check on Monday the laser powers and the ETM/ITM reflectivity for HeNe lasers. Maybe we have to increase the transimpedance gain in the heads.
|
ETMX and ETMY have 0.2 mW returning to their QPDs........so the gain must lower at ETMX
ITMX laser 1103P has only 0.67 mW output and 0.025 mW returning to the QPD.
ITMX and ETMX oplev lanching paths have lenses without AR coating. This is my fault. I will buy them.
ETMX 0.2 mW 900 counts
ITMX 0.025 1300
SRM 0.04 2600
BS 0.05 3500
PRM 0.06 4000
ETMY 0.2 9000
ITMY 0.3 14500 |
Attachment 1: oplevsums.png
|
|
6257
|
Mon Feb 6 17:06:11 2012 |
steve | Update | SUS | oplev transferfunction of PIT: ETMY & ETMX |
Kiwamu showed me how to do transferfunction of oplev pitch |
Attachment 1: ETMX_PIT.png
|
|
Attachment 2: ETMY_PIT.png
|
|
6258
|
Tue Feb 7 03:05:08 2012 |
Zach | Update | SUS | OSEM sat amp measurements |
I did some more investigation on the OSEM box today.
Troubleshooting:
After removing some capacitors and still finding that the +15V rail was at over +20V, I decided to see if the TO-3 7815 that I removed behaved properly all by itself. It did. After some more poking around, I discovered that whoever assembled the board isolated the case of the regulator from the board. It is through the case that this package gets its grounding, so I removed the mica insulator, remounted the regulator, and all worked fine.
Since I had gotten a spare from Downs, I also replaced the LT1031 (precision 10-V reference), for fear that it had been damaged by the floating voltage regulator.
Noise measurements:

LED Driver
With the above out of the way, I was finally able to take some measurements. The first thing I did was to look at the LED drivers. I fixed the one stage that I mentioned in my last post by adding two 820-ohm resistors in parallel with the 1k, such that it was very close to all the others (which are 806 || 806 || 1k). With that, using a red LED, I measured a current of 34.5 mA (+/- 0.1) out of each of the 5 stages (UL, UR, LL, LR, S).
I then measured the current noise of each one by monitoring the voltage across the 287-ohm resistor in series with the LED. The driver works by putting the LED in the feedback path of an inverting amp. There is a 10-V input from the LT1031, and the values of the input and feedback resistors determine the current drawn through the LED. There is a buffer (LM6321) in the path to provide the necessary current.
The LISO model I made according to that description seems to make sense. I simply modeled the LED as a small resistor and asked LISO for the current through it. The transfer function shows the proper DC response of -49.15 dB(A/V) --> 34.8 mA @ 10 V, but, the estimated current noise doesn't add up with the measured levels:

I have to get to the bottom of this. Two possibilities are: 1) The buffer adds noise, and/or 2) I am modeling this invalidly.
PD Amp
I also began measuring the PD amplifier noise levels, though I only measured two of them for lack of time. I find it odd that there is a 100-ohm input series resistor on what I thought would be just a transimpedance amplifier. For that reason, I want to look into how the OSEMs are connected to this guy.
In any case, I measured the output noise of two of the PD amps by shorting the input side of the 100-ohm resistors to ground, and then I divided by their TF to get the input noise level. Here it is compared with the LISO estimate. I have plotted them in units of voltage noise at the input side of the resistors for lack of a way to infer the equivalent photocurrent noise level.

Above 2 Hz or so, the measured level agrees with the prediction. Below this, the measured noise level increases as 1/f, while it should go as the standard 1/sqrt(f) (the manufacturer-quoted 1/f corner is at 2 Hz). Another thing to get to the bottom of. |
6259
|
Tue Feb 7 16:30:46 2012 |
steve | Update | SUS | ALL oplev PIT transfer functions |
SUS- BS, ITMX, ITMY, PRM, SRM, ETMX & ETMY_OLPIT transfer funtion with sine wave excitation 0.1 amplitude:
|
Attachment 1: BS_PIT.png
|
|
Attachment 2: ITMX_PIT.png
|
|
Attachment 3: itmy_pit.png
|
|
Attachment 4: PRM_PIT.png
|
|
Attachment 5: SRM_PIT.png
|
|
Attachment 6: ETMX_PIT.png
|
|
Attachment 7: ETMY_PIT2.png
|
|
6260
|
Wed Feb 8 16:37:02 2012 |
steve | Update | SUS | ITMX OSEM LL is sick |
I'm driving C1:SUS-ITMX_OLYAW and PIT_EXC with amplitude 0,1-0.3 while taking transfer funtions of oplev.
The transfer functions are normal. However I noticed that the LL osem is not responding to this excitations
Healthy sensor respons should be like Atm3 |
Attachment 1: ITMXsensorLL.png
|
|
Attachment 2: ITMXsensorLLyaw.1.png
|
|
Attachment 3: ETMX.2amplPIT2.png
|
|
6261
|
Thu Feb 9 12:38:15 2012 |
Zach | Update | SUS | OSEM LED driver noise |
Frank pointed out to me that I had dumbly forgotten to include the voltage reference's noise. The LT1031 has an output noise level of ~125 nV/rHz above 10 Hz or so, and this at least makes the estimate much closer. I had also not included an extra LT1125 stage between the reference and the other stages. I guess I was tired.

The estimate is now within a factor of a few of the measured level, and it has roughly the right shape. Around 1 Hz, it looks like the measured data begin to roll up away from the model, though it's tough to say due to the effect of the AC coupling on the analyzer less than a decade below. If there is indeed extra noise here, Frank thinks it could be due to resistor current noise.
I'll switch one or two out for nicer ones and see if things change. |
6263
|
Thu Feb 9 16:46:02 2012 |
steve | Update | SUS | ALL oplev YAW transfer functions |
Quote: |
SUS- BS, ITMX, ITMY, PRM, SRM, ETMX & ETMY_OLPIT transfer funtion with sine wave excitation 0.1 amplitude:
|
OL_YAW transfer functions are here.
I had two PHDs helping me to overlap the EXML files in DTT. We failed. This job requires professorial help. |
Attachment 1: BS-OLYAW.1ampl.png
|
|
Attachment 2: ITMX-OLYAW.1ampl.png
|
|
Attachment 3: ITMY-OLYAW.1ampl.png
|
|
Attachment 4: PRM_OLYAW.1.png
|
|
Attachment 5: SRM_OLYAW.1ampl.png
|
|
Attachment 6: ETMX-OLYAW.1ampl.png
|
|
Attachment 7: ETMY-OLYAW.1ampl.png
|
|
6264
|
Thu Feb 9 17:11:05 2012 |
steve | Update | SUS | more OSEM problems |
These observations of the OSEMs were taken while taking transfer functions of oplev YAW at excitation amplitude 0.1
Atm1, C1:SUS-ETMX_SENSOR_SIDE cross coupling
Atm2, C1:SUS-ITMX_SENSOR_LL not excitable
Atm3-4, BS and PRM insensitive
Good OSEM list: ITMY, ETMY and SRM
|
Attachment 1: ETMXosemEXC0.1ampl.png
|
|
Attachment 2: IMTX-YAW0.1.png
|
|
Attachment 3: BSosemEXC.1ampl.png
|
|
Attachment 4: PRMosemEXC.1ampl.png
|
|
6267
|
Fri Feb 10 02:43:37 2012 |
Zach | Update | SUS | OSEM LED driver noise *reduced* |
I worked on the OSEM box a little more today, with the hopes of reducing the measured output current noise. I succeeded, at least modestly. It turns out that most of the noise was indeed caused by the crappy resistors.
Below is the circuit for one of the 5 LEDs. The output of the op-amp structure directly after the LT1031 reference is split between 5 stages identical to the structure on the right. I have shown just one (UR) for clarity. The various measurement points are explained below.

I started from the beginning of the circuit, directly after the LT1031, to make sure that the excess noise seen the other day wasn't just from a noisy reference. Below is the measured output voltage noise along with the LISO estimate. Clearly, the LT1031 is performing to spec (as it should, since it's a new part that I just put in). Note that the apparent better-than-spec performance at low frequencies is just from the AC coupling, which I needed due to the high DC level.

Since the reference was in order, the next step was to switch out some of the crappy old resistors for nicer thin-film ones. In case anyone is interested, Frank has done some detailed investigation of excess 1/f current noise in resistors. I measured the voltage noise level at the point labeled "inter-stage measurement" above, first without any modifications and then after swapping the old 10k resistors (R1 & R2) out for nice Vishay thin-film ones. There is clearly a big improvement, and the modified circuit essentially agrees with LISO now down to 1 Hz. Below this, it looks like there could still be an issue.

I wanted to see what the improvement was in the overall output current noise of the system, so I went about measuring the current noise as I had the other day (by measuring the voltage noise across R55 and dividing by the resistance). The performance was already better than the old measurement, but not at the LISO level. So, I replaced the current-setting resistors (R54 & R55)---which were actually 3 parallel resistors on a single pad in each case---by nice Vishay ones, as well. I didn't have any that were close to the original resistance of ~287 ohms, so I put three 1k ones in parallel. This of course shifts the resistance up to 333 ohms, but that only causes a ~16% change in current. I was sure to convert voltage noise into current noise with this new resistance, though.
With this change, the total output current noise is now very close to the LISO estimate as well down to ~1 Hz.

Some notes:
- First, I apologize for the noise margin at higher frequencies. I redid the higher frequency measurements with an SR560 as a preamp, but I must have screwed up the calibration because the data don't match up quite right with the LF measurements. It was clear while I was taking them that they followed the LISO trace.
- There still seems some excess noise below 1 Hz. It could be that the noisy resistors in the parallel stages were somehow still contaminating the cleaned-up channel. I'll look into this more soon.
|
6270
|
Fri Feb 10 15:46:59 2012 |
steve | Update | SUS | ruby wire standoff |
Finally I found a company who can do Koji's improved -hard to make- specification on ruby or sapphire wire standoff.
NOT POLISHED excimer laser cut, wire groove radius R 0.0005" + - 0.0002" 
$250 ea at 50 pieces of order |
6278
|
Tue Feb 14 08:22:27 2012 |
steve | Update | SUS | sus damping restored |
ITMX, PRM and BS watchdogs are tripped. They were restored.
Stable MC was disabled so I can use MC_REFL 1 W beam to measure green glass . |
6305
|
Wed Feb 22 16:55:16 2012 |
Jamie | Update | SUS | wacky state of SUS input matrices |
While Kiwamu and I were trying to investigate the the vertex glitches we were noticing excess noise in ITMX, which Kiwamu blamed on some sort of bad diagonalization. Sure enough, the ITMX input matrix is in the default state [0], not a properly diagonalized state. Looking through the rest of the suspensions, I found PRM also in the default state, not diagonalized.
We should do another round of suspension diagonalization.
Kiwamu (or whoever is here last tonight): please run the free-swing/kick script (/opt/rtcds/caltech/c1/scripts/SUS/freeswing) before you leave, and I'll check the matrices and update the suspensions tomorrow morning.
[0]
0.25 |
0.25 |
0.25 |
0.25 |
0 |
1.66 |
1.66 |
-1.66 |
1.66 |
0 |
1.66 |
-1.66 |
-1.66 |
1.66 |
0 |
0 |
0 |
0 |
0 |
1 |
|
6307
|
Thu Feb 23 02:20:07 2012 |
Zach | Update | SUS | wacky state of SUS input matrices |
This reminds me that the whole Dr. SUS situation never got taken care of. Where I left off, I was having issues pulling 40m data with NDS2 (which is what all the diagonalization scripts use).
What is the deal with 40m+NDS2? If it is till no-go, can we have a consensus on whether this is too important to wait for? If so, I will rewrite the scripts to use NDS and we can upgrade to NDS2 once we can prove we know how to use it.
Quote: |
While Kiwamu and I were trying to investigate the the vertex glitches we were noticing excess noise in ITMX, which Kiwamu blamed on some sort of bad diagonalization. Sure enough, the ITMX input matrix is in the default state [0], not a properly diagonalized state. Looking through the rest of the suspensions, I found PRM also in the default state, not diagonalized.
We should do another round of suspension diagonalization.
Kiwamu (or whoever is here last tonight): please run the free-swing/kick script (/opt/rtcds/caltech/c1/scripts/SUS/freeswing) before you leave, and I'll check the matrices and update the suspensions tomorrow morning.
[0]
0.25 |
0.25 |
0.25 |
0.25 |
0 |
1.66 |
1.66 |
-1.66 |
1.66 |
0 |
1.66 |
-1.66 |
-1.66 |
1.66 |
0 |
0 |
0 |
0 |
0 |
1 |
|
|
6309
|
Thu Feb 23 10:53:54 2012 |
steve | Update | SUS | oplev PIT transfer functions |
Oplev transfer functions PIT UGF were optimized to be at 2-3 Hz with 60 degree minimum phase margin by adjuting oplev gains.
Additional Notes by KI:
- The PRM oplev has a tailored 3.3 Hz resonant gain in order to calm down a wobble during the lock acquisitions.
- Also in the PRM oplev a 35 Hz elliptic cut-off filter wasn't activated at the time when Steve measured it.
- In both ITMs, elliptic cut-off filters seem to have higher corner frequencies compered with the others.
- I guess these settings are from the old days.
- ETMs and ITMs have whitening filters while the rest of the suspensions don't.
- Without the whitening filters, normally the signals above 30 Hz are covered by some electrical noises or perhaps He-Ne laser intensity noise (#5630).
- This is why we usually use the 35 Hz elliptic filters to roll off the control noises.
- Since the ETMs and ITMs have whitening filters they potentially can have slightly higher corner frequencies in the elliptic filters.
- Of course the corner frequencies need to be re-designed in terms of the amount of noise injection to the longitudinal motion.
|
Attachment 1: oplPITtrans.pdf
|
|
6311
|
Fri Feb 24 04:12:44 2012 |
kiwamu | Update | SUS | freeswing test |
The following optics were kicked:
MC1 MC2 MC3 ETMX ETMY ITMX ITMY PRM SRM BS
Fri Feb 24 04:11:15 PST 2012
1014120690
Steve (or anyone), can you restore the watchdogs when you come to the lab in the morning ?
|
Kiwamu (or whoever is here last tonight): please run the free-swing/kick script (/opt/rtcds/caltech/c1/scripts/SUS/freeswing) before you leave, and I'll check the matrices and update the suspensions tomorrow morning.
|
|
6312
|
Fri Feb 24 08:06:52 2012 |
steve | Update | SUS | sus restored |
Quote: |
The following optics were kicked:
MC1 MC2 MC3 ETMX ETMY ITMX ITMY PRM SRM BS
Fri Feb 24 04:11:15 PST 2012
1014120690
Steve (or anyone), can you restore the watchdogs when you come to the lab in the morning ?
|
Kiwamu (or whoever is here last tonight): please run the free-swing/kick script (/opt/rtcds/caltech/c1/scripts/SUS/freeswing) before you leave, and I'll check the matrices and update the suspensions tomorrow morning.
|
|
All suspentions were restored and MC locked. PRM side osem RMS motion was high.
Atm2, Why the PRM is 2x as noisy as the SRM ? |