  5193   Thu Aug 11 15:31:43 2011 steveUpdateGeneralmalfunctioning crane at ETMY

Quote:

The horizontal trolley drive stopped working  at the east end this morning. It is working intermittently. In the worst case we can take the door off with the manual -Genie- lift.

I'm working with Konecrane to solve  the wormgear drive problem.

 Gear box found, it's  lead time one week at $825    The crane may be functional round August 25

  5212   Fri Aug 12 16:52:49 2011 steveUpdateGeneralChamber illuminator switch

I'm looking for an ether net based  power switch for turning lights on and off for the vacuum system from MEDM screen.  This is what I found

Jamie please take a look at it.

 

 

  5242   Mon Aug 15 17:38:07 2011 jamieUpdateGeneralFoil aperture placed in front of ETMY

We have placed a foil aperture in front of ETMY, to aid in aligning the Y-arm, and then the PRC.  It obviously needs to be removed before we close up.

  5245   Tue Aug 16 04:28:09 2011 kiwamuUpdateGeneraltoday's work to do

The main goal of today is to extract the pick-off beams

Today's menu :

  + If necessary steer ETMs and ITMs to make the X and Y green beam flashing.

  + Open the IOO and OMC chamber and lock MC.

       => cover the place of the access connector by a large piece of aluminum foil. It will give a robust lock of MC.

  + Check the beam pointing down to Y arm by looking at the ETMY face camera.

        => If it's necessary align PZT1 and PZT2 from EPICS to make the IR beam flashing in the X arm.

  + Align BS and let the beam hit the center of ETMX to make the X arm flashing.

        => These alignment procedure will automatically gives us the MICH fringes on the AS CCD camera.

  + Rotate the SRM tower to get the SRMI fringes on the AS CCD camera.

        => This is because the required amount of the YAW correction on SRM is currently beyond the range of the DC bias.

  + Align PRM to get the PRMI fringes on AS CCD camera. Also make sure the beam comes back to the REFL CCD camera.

  + Lock the PRC to make POP/POX/POY bright enough.

     => Probably the REFL11 RFPD needs more power. To increase the power, just rotate the HWP, which is sitting before the RFPDs on the AS table.

     => If the signal on AS55 is too small, we can use REFL11_Q or REFL55 for the MICH lock.

  + OR inject and align the ABSL laser to make those pick-off beams bright enough.

     => This case we don't have to make the DRMI exactly on the resonance, what we need is just the DRMI flashing.

  + Align necessary optics for those pick-off beams.

     => In our definition (aLIGO definition) POP is the beam propagating from BS to PRM. Don't be confused by another one, which propagates from PRM to BS.

  + Steer two mirrors on the ETMY table for aligning IPANG. Also, steer some mirrors on the BS table for IPPOS.

    => IPANG has already reached the ETMY table, so ideally we don't have to steer a mirror on the BS table.

    => IPPOS/ANG are very visible with a sensor card.

  + Align some oplevs.

     => This work is relatively independent from the other tasks. Steve can take care of it.

  + Adjust the OSEM to their mid-range.

     => This work can be done anytime, but everytime we have to recover the alignment of the interferometer.

  5248   Tue Aug 16 11:49:17 2011 jamie, jenneUpdateGeneraltoday's work to do

>If necessary steer ETMs and ITMs to make the X and Y green beam flashing.

Green is now flashing in both X and Y arms

>Open the IOO and OMC chamber and lock MC.

Open, and cover in place. MC is flashing and locking.

 

  5250   Tue Aug 16 17:09:55 2011 JenneUpdateGeneraltoday's work to do

Quote:

  + Rotate the SRM tower to get the SRMI fringes on the AS CCD camera.

        => This is because the required amount of the YAW correction on SRM is currently beyond the range of the DC bias.

 Kiwamu aligned things for me, and I rotated the SRM tower so that the reflected beam was pretty much totally overlapping the incident beam.  The SRC was aligned to make sure things were good.  Now the DC bias for SRM Yaw is ~1.4, so we're totally good. 

To rotate SRM, Jamie had the idea of using 2 screws so I could push the tower on one side, and back off the screw an equal amount on the other side and push the tower to be touching both screws again, to ensure that I was rotating about the center of the tower and wasn't introducing any Pos action. 

While I was at it, I also moved the OSEM connector tower back to its normal place on the table, so it's not in the way of oplev beams.  It had been moved previously to accommodate ITMY near the door.

  5252   Wed Aug 17 03:10:06 2011 kiwamuUpdateGeneralcurrent status of in-vac work

[Jamie / Suresh / Kiwamu] 

The in-vac work is ongoing.

Before we run out our energy we are posting this entry to briefly report the current status.

- (done) BS earthquake stop adjustment.

- (done) PRM earthquake stop adjustment

- (done) MC spot position check => They are almost the same within 10 %.

- (done) Injection and alignment of the ABSL laser to make the beam brighter in the vertex region.

- (done) POY => We repositioned an in-vac steering mirror to get the POY beam hitting the center of the steering mirror.

                           It's now coming out from the chamber.

(done)  IPANG => realigned two mirrors on the ETMY table to get the IPANG out from the chamber. Now it's reaching the ETMY optical table.

                             It needs a final touch before we pump down.  We revisited it later in the night after realigning the IFO and it is well aligned now.

- (done)  POP => We have aligned the ABSL laser injected from the AS port to reach the REFL camera.  We turned it up to max power of 300mW and used it as a substitute for the PRC beam.

                         Even this was not enough to see anything in the POP beam path after the PR2 (tip-tilt).  So we used a green beam from the Y-arm as a guide of the POP beam path because the ABSL (POP) beam was too dim to work with.

                         We placed a lens and a CCD camera to detect the green and then blocked the Y-green.  It was then possible to see the ABSL-POP beam in the CCD camera.  The lens and the CCD are markers for this beam. 

                         Do not remove these markers unless absolutely necessary.

-(done) POX => We located the ABSL (mimicking POX) beam on the POXM1 mirror and adjusted the mirror to ensure that the beam exits at the right height and a convenient location on the POX table. 

- (0%) OSEM mid-range adjustment

- (0%) IPPOS

- (0%) oplev re-alignment

  5253   Wed Aug 17 06:42:38 2011 kiwamuUpdateGeneralin-vac work : the end is near

We will pump down the chambers on Thursday morning.

Today will be a day of the OSEM and oplev party.

 

 -- to do list for today --

 + OSEM mid-range adjustment

 + oplev realignment

 + placement of beam traps

 + extraction of IPPOS

 + table leveling

 + interferometer alignment

 + AM-PM mystery

 + preparation for drag and wipe

  5256   Wed Aug 17 15:55:01 2011 JenneUpdateGeneralin-vac work : the end is near

Quote:

We will pump down the chambers on Thursday Friday morning.

 All hands on deck at 9am Thursday for drag wiping and doors.  We'll do the 5 doors first (including drag wiping), then put on the access connector last.  Steve will then begin pumping early Friday morning.

  5258   Wed Aug 17 20:14:49 2011 jamie, kiwamu, suresh, jenne, keiko, anamariaUpdateGeneralin-vacuum work status, prep for pump

This afternoon's work:

  • OSEMs were adjusted on all suspended optics.
  • X and Y-arms were aligned to green.
  • Once that was done, the input pointing was adjusted with the PZTs to get the IR beam centered on ITMY and ETMY.
  • Once the input pointing was ok we extracted IPANG and IPPOS.
  • BS, ITMY, PRM, SRM optical levers (oplevs) were extracted.
  • Prepared rails and stops for TMs for morning drag wiping.

TODO before drag wiping:

  • Check full IFO alignment.
  • Readjust OSEMs if needed.
  • Extract ITMX oplev.
  5259   Thu Aug 18 00:53:48 2011 jamie, kiwamu, suresh, jenneUpdateGeneralPUMP PLAN ABORTED; need to work more on IFO alignment

We have decided that the IFO alignment is bad enough that we're not ready to pump down.  PUMP ABORTED.

The IFO alignment is somewhat OK, in that the green and IR beams are flashing in the arms, and the return beams are overlapping at the BS.  However the beams appear to be not centered on any of the optics at the moment.  They are all displaced in yaw by ~0.5 to 1 cm or so in various directions.

From this we have decided that we need to step back and reattack the IFO alignment from square one.  Here is our current suggested procedure:

  1. check ETM positions relative to what we think they should be on the drawings.  This is to verify that the ETMs were not placed in the wrong places laterally.
  2. translate Y green axis north, centering green on ETMY and ITMY (by looking at cards).  North is the opposite direction from how the beams are displaced from the TM centers.
  3. steer input pointing to overlap IR on green beam at BS, ITMY, and ETMY.  IR should visibly overlap green at both BS and ITMY, and we should be able to see IR on target in front of ETMY with ETMY face camera, and in ETMY trans camera.
  4. center IR on ETMX by steering BS with DC bias.
  5. align Y arm cavity for green resonance by adjusting ITMY.
  6. adjust ITMX to achieve michelson fringes at AS
  7. adjust PRM lateral translation to center beam on PRM, if needed
  8. adjust SRM lateral translation to center beam on SRM, if needed
  9. align PRC to see fringes
  10. align SRC to see fringes
  11. extract AS (no clipping)

 Once this is done, we will need to check the following:

  • IPANG/IPPOS extraction
  • pick-off extraction
  • OPLEVs
  • OSEMs
  • green periscopes and green beam extraction at PSL

We've decided to stop for the night, get a good nights rest, and attack all of this tomorrow morning.

Beam_spot_shifts.png

  5267   Fri Aug 19 01:46:06 2011 SureshUpdateGeneralIFO alignment

[Keiko, Jamie, Kiwamu, Anamaria,

We followed the procedure that we laid-out in our elog of yesterday.  We completed the first six steps and we now have the y-arm well aligned to the green beam which passes through the center of of both ETMY and ITMY. 

The IR beam was steered with the PZTs to coincide with the green beam.  The BS was adjusted to see IR beam scatter on a target placed near the center of the ETMX.  And then the AS IR beam was steered to the AS camera by adjusting several components along OM path ( we touched OM1, OM2, OM3, OM4, OM5, OMPO and OM6).  We then looked for IR fringes in the AS port from the Y-arm. But no luck there.  We need to realign the IR beam into the Y-arm cavity axis using the pzts.

We aligned ITMX and PRM to get power recycled Michelson fringes at the AS.

 

  5270   Fri Aug 19 15:31:53 2011 steveUpdateGeneralpower interruption rescheduled to 10-1-2011

                UTILITY & SERVICE INTERRUPTION

**PLEASE POST**

 

Building:               Central Engineering Services (C.E.S.)

          LIGO Gravitational Physics building adjacent to C.E.S. 40M- Lab

          Safety Storage adjacent to CES

          Steele House 

          Keck Lab

 

Date:                   Saturday, October 1, 2011

Time:                   8:00 a.m. To 9:00 a.m.            

Interruption:   Electricity

Contact:                Mike Anchondo ext. 4999  Tom Brennan 4984

*This interruption is required for maintenance of high voltage switchgear in Campus Sub Station.

(If there is a problem with this Interruption, please notify

 the Service Center X-4717 or the above Contact as soon as possible.

 If no response is received we will proceed with the interruption.)

         

                                Reza Ohadi,

                                Director, Campus Operations & Maintenance

  5275   Mon Aug 22 02:43:28 2011 kiwamuUpdateGeneralin-vac work

[Kieko / Kiwamu]

 The AS beam shows a little bit of clipping and right now this is the only concern for the alignment of the interferometer.

Other than that everything is okay including :

  + Beam centering on all the suspended optics

  + Arm cavity alignments. The Fabry-Perot fringes from both arm cavity were found on the AS camera.

  + POX/POY/POP, they are still successfully coming out from the chambers

  + IPPOS/ANG

  + Alignment of the green beams and the associated optics. Both green are reaching to the PSL table

 

We need to check/fix the AS beam clipping and once it's done we will readjust the OSEM mid range and the oplevs.

Then it will be ready for the drag/wipe and door closing.

  5277   Mon Aug 22 16:28:44 2011 SureshUpdateGeneralSRM tower shifted on Friday

[Kiwamu, Suresh]   This is a belated elog entry from last Friday night + Saturday morning! 

    We shifted the SRM tower across the beam and away from the door by about 5mm. 

                  After the input beam from MC was aligned to the Y-arm,  Kiwamu noticed that the AS beam was being clipped and that the correction had to start from SRM onwards as the beam had become offcentered on the SRM.  So we shifted the SRM tower by about 5mm away from the door and transverse to the beam and rotated it by a few degrees to center the OSEM offsets.  After this we aligned all optics along the AS beam path to extract the AS beam from the chamber.    We then aligned each optic in the vertex so that their beams overlap at the AS port with the reflection from ITMY.  Then we aligned BS to center the beam on ETMX and then looked for flashes from the Y arm.

      At this point Kiwamu checked and found that the input beam from the MC had shifted.  It was landing on the ITMY about 5mm below the center.  And (inexplicably) it was still centered on ETMY!  The Y- green which traced the cavity axis (since this was still flashing) was not coincident with the IR beam.   So all the work we did in aligning the AS beam and the vertex optics work was lost..... and had to be done again.

 

 

  5279   Mon Aug 22 21:32:10 2011 kiwamuUpdateGeneralmore in-vac work : AS clipping fixed and OSEM/oplev adjustment

[Keiko / Jenne / Jamie / Kiwamu]

 We did the following things today :

  + fixed the AS clipping issue

  + realigned all the oplevs

  + checked and adjusted the all OSEM DC values, including PRM, SRM, BS, ITMs, ETMs, MC1 and MC3

 

Since we touched the OSEMs the alignment has changed somewhat.

Right now Jenne, Suresh and I are working on the "confirmation alignment".

Once we find the alignment is still good (steerable by the PZTs and the DC coil bias), tomorrow we will do the drag&wipe and door closing.

Quote from #5275

We need to check/fix the AS beam clipping and once it's done we will readjust the OSEM mid range and the oplevs.

 

  5280   Tue Aug 23 00:55:13 2011 JenneUpdateGeneralIFO ready for doors

[Kiwamu, Jenne]

After the IFO was aligned in air one final time, we tapped on a few OSEMs until we were happy with all of the centering of all of the optics' OSEMs.  All are within 0.05 of their halfway values, with the exception of one each on MC1 and MC3, one of which is within 0.06, and the other 0.08.  Because of the realignment pain of dealing with MC OSEMs, we elected to leave these alone.  Also, since we obviously didn't open the MC2 tank, we don't know how they are, although the numbers look reasonable. 

Also, we took photos (to be posted on Picasa in a day or two) of all the main IFO magnet-in-OSEM centering, as best we could.  SRM, BS, PRM all caused trouble, due to their tight optical layouts.  We got what we could.  Various people have been looking at these for the past 2 weeks, and I think they're all fine, even if we didn't get stellar photos.

We are now prepared for pumping.  For real this time.

 

  5284   Tue Aug 23 06:49:24 2011 AnamariaUpdateGeneralmore in-vac work : AS clipping fixed and OSEM/oplev adjustment

Where was the AS clipping?! Ah, the suspense...

Quote:

  + fixed the AS clipping issue

 

Quote from #5275

We need to check/fix the AS beam clipping and once it's done we will readjust the OSEM mid range and the oplevs.

 

 

 

  5285   Tue Aug 23 09:40:37 2011 kiwamuUpdateGeneralRe: AS clipping fixed

Indeed it was suspenseful.

We tried finding where the clipping happened, but we couldn't find any obvious clippings.

So we checked centering of the beams on all the optics associated with the AS path, starting from BS, SR3,... to the AS optical bench.

And during the work some of them were recentered.

At the end we found no clipping. To make sure we tested the available range (no clipping range) by exciting the angular motion of BS with AWG (f ~ 1Hz, a ~ 1000).

The beam looked successfully coming out at the most of the angular oscillation point.

Quote from #5284

Where was the AS clipping?! Ah, the suspense...

 

  5307   Fri Aug 26 10:45:17 2011 steveUpdateGeneral crane at ETMY is fixed

Quote:

The horizontal trolley drive stopped working  at the east end this morning. It is working intermittently. In the worst case we can take the door off with the manual -Genie- lift.

I'm working with Konecrane to solve  the wormgear drive problem.

 New gear box installed and tested by Fred KoneCranes.

Attachment 1: P1080190.JPG
P1080190.JPG
Attachment 2: P1080188.JPG
P1080188.JPG
  5309   Fri Aug 26 15:59:33 2011 steveUpdateGeneraldrawer cabinet moves in

manufacturer info

Jamie and Shuresh moved in Jenne's 11 drawers cabinet and relocated old note book boxes on the inside of the vac tube.

Attachment 1: P1080192.JPG
P1080192.JPG
  5310   Fri Aug 26 16:17:31 2011 JenneUpdateGeneraldrawer cabinet moves in

Quote:

Jamie and Shuresh moved in Jenne's 11 drawers cabinet and relocated old note book boxes on the inside of the vac tube.

 Barring other chores for next Wednesday, we're going to spend Wednesday afternoon populating the new cabinet with all of the optics hardware: posts, forks, dogs, everything!  It's going to be so organized and awesome!!

  5330   Wed Aug 31 16:18:25 2011 JenneUpdateGeneralNew Optics Drawers

[Kiwamu, Manuel, Jenne]

The new optics storage drawers have been populated with optics.  Each drawer is labelled.  Harsh punishments will be inflicted on anyone found disobeying the new scheme.

  5343   Tue Sep 6 11:27:19 2011 JenneUpdateGeneralAfternoon pre-pumpdown todo list

These are the things that I can think of that we need to do before we can close up:

* Take a close look at both ITMs' OSEMs, and ensure that the magnets aren't too close to either plate in the OSEMs.  Both have had funny business over the past week.

* Do a free swinging test on both ITMs.  (ITMY may not need it, if we haven't touched it since the last free swinging test, but it can't hurt to take the data)

* Confirm that POX is exiting the chamber.

* Is there anything else???

 

Our goal is to finish this work by tonight, so that we can close doors and start pumping tomorrow.

  5405   Wed Sep 14 14:06:44 2011 kiwamuUpdateGeneralminutes of 40m meeting : plans
+ Optical lever (Steve/Paul)
+ LSC demod board (Keiko)
+ DRMI locking (Keiko / Anamaria)
+ Modulation depth (Mirko)
+ ALS (Katrin)
+ MC WFS (Suresh)
+ OAF (Jenne/Mirko)
+ MC_F acquisition (Jenne/Mirko)
+ SUS, free swinging (Jenne)
+ CDS (Jamie)
+ vent plan (Jamie)
+ EOM (Kiwamu)
+ PZT-HV (Kiwamu/Koji)
  5455   Mon Sep 19 02:33:34 2011 kiwamuHowToGeneralPlan for this week

GOAL1:  Stable lock of DRMI

GOAL2:  Measurement of the LSC input matrix in the DRMI configuration

 

 /- - Daytime works - - /

  + Measurement of the arm lengths (Jenne / Kiwamu / volunteers)

  + Optimization of the oplev control loops (Paul)

  + Inversion and installation of the SUS input matrices (Jenne)

  + Tuning of the SUS damping gains (Steve)

  + Measurement of the modulation depths (Mirko)

  + Preparation of the green broadband PD (Katrin)

  + Fixing the Y arm green lock servo (Katrin / Kiwamu)

  + Installation of RFPDs (Anamaria)

  + Minimization of the AM sidebands (Anamaria / Keiko)

  + Preparation of a script for measuring the LSC input matrix (Keiko)

  + MC WFS (Suresh)

  + Online adaptive filtering (Mirko / Jenne)

  + Modification of C1ASS (Kiwamu)

  + Fixing IPPOS (volunteers) 

  + Auto alignment of PRCL and SRCL (volunteers)

  + Loss measurement of the arm cavities (volunteers)

  + Fixing the ETMX SIDE slow monitor (volunteers)

 

 /- - Nighttime works - - /

 + Locking of DRMI

 + Characterization of DRMI and complete the wiki page

  5456   Mon Sep 19 11:49:32 2011 JenneHowToGeneralPlan for this week: SUS inversion

Quote:

  + Inversion and installation of the SUS input matrices (Jenne)

 It turns out that this is complicated, since there are so many people working with the IFO this week.  What I would like to do is put in the new input matricies, and then do a free swinging test, to see if the suspensions are really diagonalized in the way that we want them to be.  I can't do this during the day, since it will interfere with Paul's OpLev work.  And at "night", I can't, since we'll be doing locking.  So, this may be a late-night task.  I'll write a script this afternoon that will put in all of the new input matricies, and then run the freeswing and the restore watchdogs scripts.  Whomever is the last one to leave for the night can run the combo script.

EDIT:  As of this time (~11:45am), ITMY has its new input matrix.

  5591   Fri Sep 30 19:12:56 2011 KojiUpdateGeneralprep for poweroutage

 

 [Koji Jenne]

The lasers were shutdown

The racks were turned off

We could not figure out how to turn off JETSTOR

The control room machines were turned off

FInally we will turn off nodus and linux1 (with this order).

Hope everything comes back with no trouble

(Finger crossing)

  5592   Sat Oct 1 17:47:21 2011 KojiSummaryGeneralRecovery from the power shutdown

[Steve Koji Kiwamu]

- The storage on linux1 and linux1 itself (with this order) were turned on at 10:30am

- Kiwamu restored the vacuum system

   => opened V4, started TP1 (maglev) and opened V1.

      The pressure went downfrom 2.5 mTorr to the normal level in about 20 minutes.

- A regular fsck of linux1 was completed at 5pm

- Nodus was turned on. Mounting /cvs/cds succeeded

- The control room computers were turned on

- The rack power for FB turned on, FB and megatron started.

- Kiwamu and Koji went through all of the rack powers and started the slow and fast machines.
As we found Solensen for -15V at ETMX was current limited. +/-15V were turned off for now.
==> Kiwamu turned on Solensen again for investigation and found it became okay.
It's now ON.
 
- c1sus and c1ioo had many red lamps on the FE status screen.
Ran killc1XXX for all of the FE codes on c1lsc and c1ioo.
Then, made software reboot (sudo shutdown -r now)
All of the FEs shows green (after some randome clicking of DIAGRESETs)

- HVs on 1X1 were turned on. The are not vacuum HV, but used only in the air

- Turned on the RF generation box and the RF distribution box

- burtrestore slow machines (c1psl, c1susaux, c1iool0, c1iscaux, c1iscaux2, c1auxex, c1auxey)

  5593   Sat Oct 1 22:53:49 2011 kiwamuSummaryGeneralRecovery from the power shutdown : lockable

Found the Marconi for the 11 MHz source had been reset to its default.

 => reset the parameters. f = 11.065910 MHz (see #5530) amp = 13 dBm.

Interferometer became lockable. I checked the X/Y arm lock, and MICH lock, they all are fine.

  5596   Sun Oct 2 13:45:13 2011 ranaSummaryGeneralRecovery from the power shutdown: apache / svn

Restarted Apache on nodus using Yoichi's wiki instructions. SVN is back up.

  5634   Fri Oct 7 22:41:05 2011 KojiConfigurationGeneralScript backup fixed

Script backup regularly runs on op340m by crontab,
but the true backup were not taken since Oct 16, 2010
as the backup program was looking at the old script directory.
/cvs/cds/script/backupScripts.pl was modified to look at the new script directory.

OLD COMMAND:

$command = "cd /cvs/cds/caltech; /usr/sbin/tar cfX - $EXCLUDE_LIST scripts | bzip2 > $ARCHIVEDIR/scripts_$curdate.tar.bz2";

NEW COMMAND:

$command = "cd /opt/rtcds/caltech/c1; /usr/sbin/tar cfX - $EXCLUDE_LIST scripts | bzip2 > $ARCHIVEDIR/scripts_$curdate.tar.bz2";

  5698   Wed Oct 19 14:03:41 2011 kiwamuUpdateGeneralvent prep : dichroic mirrors

Status update on dichroic mirror:

 I got the specification sheet of an aLIGO 2" dichroic mirror from Lisa.

https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=25232

This is the one from ATF. It has low loss, a high R for 1064 nm and high T for 532 nm. So it matches our needs.

Based on this sheet we may reset some of the parameters in the specification (e.g. incident angle and etc.,) and will get a quote from ATF.

We will buy 3 of them, including 1 spare. First I need to review the specification.

  5728   Mon Oct 24 14:26:01 2011 steveUpdateGeneralno electricity on Nov. 19
Subject: Electricity Interruption- 11/19/11
From: "PP Service Center" <PPService@caltech.edu>
To: "DeLaRosa, Dario" <Dario.DeLaRosa@caltech.edu>,
         ...snip... "Sullivan, Joan O." <sully@caltech.edu>

 

CALIFORNIA INSTITUTE OF TECHNOLOGY

                   FACILITIES MANAGEMENT

              UTILITY & SERVICE INTERRUPTION

 

**PLEASE POST**

 

 

Building:            Central Engineering Services (C.E.S.)

LIGO Gravitational Physics building adjacent to C.E.S.

Safety Storage adjacent to CES

Steele House 

Keck Lab

 

Date:                November 19, 2011

 

Time:                8:00 a.m. To 9:00 a.m.

 

Interruption:        Electricity

 

Contact:             Mike Anchondo ext. 4999  Tom Brennan 4984

 

*This interruption is required for maintenance of high voltage switchgear in Campus Sub Station.

 

 

  5741   Wed Oct 26 10:07:16 2011 steveUpdateGeneralno electricity ....... will be recheduled

Quote:
Subject: Electricity Interruption- 11/19/11
From: "PP Service Center" <PPService@caltech.edu>
To: "DeLaRosa, Dario" <Dario.DeLaRosa@caltech.edu>,
         ...snip... "Sullivan, Joan O." <sully@caltech.edu>

 

CALIFORNIA INSTITUTE OF TECHNOLOGY

                   FACILITIES MANAGEMENT

              UTILITY & SERVICE INTERRUPTION

 

**PLEASE POST**

 

 

Building:            Central Engineering Services (C.E.S.)

LIGO Gravitational Physics building adjacent to C.E.S.

Safety Storage adjacent to CES

Steele House 

Keck Lab

 

Date:                November 19, 2011

 

Time:                8:00 a.m. To 9:00 a.m.

 

Interruption:        Electricity

 

Contact:             Mike Anchondo ext. 4999  Tom Brennan 4984

 

*This interruption is required for maintenance of high voltage switchgear in Campus Sub Station.

 

 

CANCELLED, WILL BE RESCHEDULED*

  5783   Wed Nov 2 10:41:47 2011 steveUpdateGeneral2 spare heliax at the LSC rack

They were traced and labeled. One goes to 1X2 and the other to AS-ISCT. They are Andrew Heliax 1/4" od. made by CommScone,  model number FSJ1-50A

  5827   Mon Nov 7 08:25:15 2011 steveUpdateGeneralno electricity on Nov. 20

The Nov.19 interruption was rescheduled to be on Nov.20,2011

          CALIFORNIA INSTITUTE OF TECHNOLOGY

                 FACILITIES MANAGEMENT

            UTILITY & SERVICE INTERRUPTION

 

**PLEASE POST**

 

 

Building:         CENTRAL ENGINEERING SERVICES, STEELE HOUSE, KECK LAB,

                  LIGO GRAVITATION PHYSICS BLDG, SAFETY STORAGE (BY CES)

 

Date:             Sunday, Nov. 20,2011

 

Time:             10:00 AM TO 11:00 AM

 

Interruption:     ELECTRICITY

 

Contact:          MIKE ANCHONDO X-4999 OR TOM BRENNAN X-4984

 

*THIS INTERRUPTION IS REQUIRED FOR MAINTENANCE OF HIGH VOLTAGE SWITCHGEAR

IN CAMPUS SUB-STATION.

  5831   Mon Nov 7 14:58:17 2011 steveUpdateGeneralChamber illuminator remote switches installed

nullQuote:

I'm looking for an ether net based  power switch for turning lights on and off for the vacuum system from MEDM screen.  This is what I found

Jamie please take a look at it.

 

 

 I installed 4 remote AC power on/off strip at

1Y1   for the Vertex area 4 chamber illuminating lights ( CIL )

1Y3   for HV ps for PZT steering mirrors that should be interlocked with P1 pressure gauge. Power off above 3 mTorr

1Y4   for  ETMY CILs,

1X9   for ETMX CILs

I need one volunteer to help me to make MEDM screen and connect the network to the switches.

  5850   Wed Nov 9 16:03:21 2011 kiwamuSummaryGeneralGoal this week

Goal of this week :  ALS on the Y arm

Minimum success : Detection of the green beatnote between the freq-doubled PSL and the Y arm transmitted light

  5885   Mon Nov 14 11:32:02 2011 kiwamuSummaryGeneralGoal this week

Goal of this week : Noise budgeting on the Y arm ALS

Minimum success : bring the Y arm to the resonance by using ALS  NOISE BUDGETING!!!

 => as a preparation the incident beam pointing needs to be fixed by steering the MC suspensions.

Quote from #5850http://nodus.ligo.caltech.edu:8080/40m/5850

Goal of this week :  ALS on the Y arm (DONE)

  5963   Sun Nov 20 14:48:55 2011 kiwamuUpdateGeneralrecovery from the power shutdown

Recovery from the power shutdown

 - Turned on the raid disk of linux1.

 - Woke linux1 up. No fsck this time.

 - Woke up all the lab machines.

 - Turned on all the electronics racks' AC powers

 - Woke up fb and then front end machine (the raid for fb had been already up as I turned on the AC powers)

 - Turned on all the electronics racks' DC powers (Sorensens, Kepcos, and etc.)

 - Turned on the Marcnois which is driving the RF generation box.

 - Woke up all the lasers (PSL and End lasers)

 - Some burtrestoring (c1ioo, c1sus, c1susaux, c1msc, c1psl, c1iool0, c1auxey, c1auxex, c1oaf, c1pem)

 - Ran autolockMC scripts on op340m => After relocking of PMC a lock of MC was acquired immediately.

 - Turned on the PZT HV drivers.

 

Some issues

 - One of the Sorensens in 1X8 rack is showing the current limit sign. This is exactly the same situation as we saw before (#5592).

       Currently it's off. It needs an investigation to find who is drawing such a large amount of current.

 - C1SCX is not properly running. Rebooting the machine didn't help. This needs to be fixed.

       The symptom is : (1) all the values are frozen in the screens. (2) the c1scx status screens shows NO SYNC sign. (3) however the timing board looks blinking happily.

 - One of the VME rack on 1X3 is not showing the +/-15V green LED lights.

   This is the one on very upper side of the rack, which contains the old c1lsc machine and c1iscaux2. If we are still using c1iscaux2, it needs to be fixed.

  5965   Sun Nov 20 15:33:37 2011 ranaUpdateGeneralrecovery from the power shutdown

 restarted Apache on Nodus for the SVN as per wiki instructions

  5989   Wed Nov 23 16:48:39 2011 SureshUpdateGeneralcable cleanup

[Koji Suresh]

As part of the general lab clean up we removed many unused BNC cables (long and short) from around the SP table.  We removed one very long BNC cable which was connected on one side to an PEM input and not connected on the other side near the 1X2 rack..   There were several cables from an old SURF phase camera project which were still attached to a couple of RF amps on the SP tables and running towards the 1X6 rack. 

We also removed some unused power cables  plugged into a power distribution strip near Megatron.

 

  5992   Wed Nov 23 22:58:33 2011 KojiUpdateGeneralc1iscaux2 is back (re: recovery from the power shutdown)

Keying again did not help to solve the issue. I turned off the power at the back of the crate, and turn it on again.
Then the key worked again.

c1iscaux2 is burtrestored and running fine now.

Quote:

 - One of the VME rack on 1X3 is not showing the +/-15V green LED lights.

   This is the one on very upper side of the rack, which contains the old c1lsc machine and c1iscaux2. If we are still using c1iscaux2, it needs to be fixed.

 

  5993   Thu Nov 24 01:28:09 2011 kiwamuUpdateGeneral1X8 sorensen came back

Quote from #5963

 - One of the Sorensens in 1X8 rack is showing the current limit sign. This is exactly the same situation as we saw before (#5592).

       Currently it's off. It needs an investigation to find who is drawing such a large amount of current.

 The 1X8 Sorensen's issue has been solved somehow.

 To investigate what is going on with the Sorensen in the 1X8 rack, I turned on the Sorensen.
Then this time it didn't show the current limit sign, the voltage went up to 15.0, where it is supposed to be.
Surprisingly this is exactly the same recovery process as we saw before (#5592).
  5994   Thu Nov 24 02:23:43 2011 KojiSummaryGeneralGPIB<->WIFI

GPIB<->WIFI on Agilent Network Analyzer 4395A was broken.
The connection was fixed by replacing and configuring the LINKSYS bridge.

=======

Kiwamu and I have identified that the LINKSYS bridge was guilty.

I knew that we had another one in the bathroom, I configured it.

HOW TO CONFIGURE IT

  • You need a host with 192.168.1.*.
  • Connect the host and the LINKSYS directly
  • Open http://192.168.1.226/
  • Select 40MARS and infrastructure mode
  • Register it in the MAC filter of the 40MARS (see wiki and use your head)

The new unit works fine.

I checked the malfunctioning unit and the configuration was the same as the others.

The bad one detected the existence of 40MARS during the configuration, but it does not establish
the connection in the actual use. I am afraid that something is broken or some setting is lost
during the power supply shutdown.

  6019   Sat Nov 26 19:37:12 2011 DenUpdateGeneralfoton files

 I've checked foton files for small numbers. There are several other filters besides "Cheby" that are presented with small numbers. For example, "BTW0.01" in the LOCKING_Q, LOCKING_I modules,  "SeisDaytime"  in the SUP_MC3_SP_NOISE and others. The output of the commands is presented below.

>chans

>cat C1???.txt | grep e-23

 

SUP_MC3_SP_Y_NOISE 2 12 4  16384      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUP_MC3_SP_YAW_NOISE 2 21 4      0      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUP_MC3_SP_ROLL_NOISE 2 21 4      0      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUP_MC3_SP_PIT_NOISE 2 21 4      0      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUP_MC2_SP_Y_NOISE 2 12 4  16384      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUP_MC2_SP_YAW_NOISE 2 21 4      0      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUP_MC2_SP_ROLL_NOISE 2 21 4      0      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUP_MC2_SP_PIT_NOISE 2 21 4      0      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUP_MC1_SP_Y_NOISE 2 12 4  16384      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUP_MC1_SP_YAW_NOISE 2 21 4      0      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUP_MC1_SP_ROLL_NOISE 2 21 4      0      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUP_MC1_SP_PIT_NOISE 2 21 4      0      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUS_MC3_SUSYAW 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_MC3_SUSSIDE 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_MC3_SUSPOS 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_MC3_SUSPIT 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_MC3_LSC 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_MC2_SUSYAW 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_MC2_SUSSIDE 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_MC2_SUSPOS 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9978637592754149   0.9978663974923444   2.0000000000000000   1.0000000000000000

SUS_MC2_SUSPIT 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_MC1_SUSYAW 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_MC1_SUSSIDE 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_MC1_SUSPIT 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_SRM_SUSYAW 3 12 4  32768      0 Cheby         1.1175580413719e-23    -1.99726998010527     0.99727436063954     2.00000000000000     1.00000000000000

SUS_SRM_SUSPOS 3 12 4  32768      0 Cheby         1.1175580413719e-23    -1.99726998010527     0.99727436063954     2.00000000000000     1.00000000000000

SUS_SRM_SUSPIT 3 12 4  32768      0 Cheby         1.1175580413719e-23    -1.99726998010527     0.99727436063954     2.00000000000000     1.00000000000000

SUS_PRM_SUSYAW 3 12 4  32768      0 Cheby         1.1175580413719e-23    -1.99726998010527     0.99727436063954     2.00000000000000     1.00000000000000

SUS_PRM_SUSPOS 3 12 4  32768      0 Cheby         1.1175580413719e-23    -1.99726998010527     0.99727436063954     2.00000000000000     1.00000000000000

SUS_PRM_SUSPIT 3 12 4  32768      0 Cheby         1.1175580413719e-23    -1.99726998010527     0.99727436063954     2.00000000000000     1.00000000000000

SUS_ETMX_SUSYAW 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_ETMX_SUSSIDE 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_ETMX_SUSPOS 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_ETMX_SUSPIT 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_ETMX_LOCKIN1_I 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

SUS_ETMX_LOCKIN1_Q 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

SUS_ETMX_LOCKIN2_I 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

SUS_ETMX_LOCKIN2_Q 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

SUS_ETMY_SUSYAW 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_ETMY_SUSSIDE 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_ETMY_SUSPOS 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_ETMY_SUSPIT 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SUS_PIT_NOISE_FILT 2 21 4      0      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUS_ROLL_NOISE_FILT 2 21 4      0      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUS_YAW_NOISE_FILT 2 21 4      0      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUS_Y_NOISE_FILT 2 12 4  16384      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUS_PIT_NOISE_FILT 2 21 4      0      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUS_ROLL_NOISE_FILT 2 21 4      0      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUS_YAW_NOISE_FILT 2 21 4      0      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

SUS_Y_NOISE_FILT 2 12 4  16384      0 SeisDaytime    4.3736847644382e-23    -1.99994247406600     0.99994247737496    -0.00000000000000    -1.00000000000000

BS_LOCKIN2_Q 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

BS_LOCKIN2_I 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

BS_LOCKIN1_Q 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

BS_LOCKIN1_I 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

BS_SUSPIT 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

BS_SUSPOS 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

BS_SUSSIDE 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

BS_SUSYAW 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

ITMX_LOCKIN2_Q 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

ITMX_LOCKIN2_I 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

ITMX_LOCKIN1_Q 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

ITMX_LOCKIN1_I 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

ITMX_SUSPIT 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

ITMX_SUSPOS 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

ITMX_SUSSIDE 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

ITMX_SUSYAW 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

ITMY_LOCKIN2_Q 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

ITMY_LOCKIN2_I 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

ITMY_LOCKIN1_Q 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

ITMY_LOCKIN1_I 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

ITMY_SUSPIT 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

ITMY_SUSPOS 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

ITMY_SUSSIDE 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

ITMY_SUSYAW 3 21 4      0      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

PRM_LOCKIN2_Q 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

PRM_LOCKIN2_I 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

PRM_SUSPIT 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

PRM_SUSPOS 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

PRM_SUSSIDE 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

PRM_SUSYAW 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SRM_LOCKIN2_Q 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

SRM_LOCKIN2_I 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

SRM_LOCKIN1_Q 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

SRM_LOCKIN1_I 5 21 2      0      0 BTW0.01     1.351815922494362e-23  -1.9999929139431329   0.9999929139578397   2.0000000000000000   1.0000000000000000

SRM_SUSPIT 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SRM_SUSPOS 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

SRM_SUSSIDE 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

 

SRM_SUSYAW 3 12 4  32768      0 Cheby       1.117558041371939e-23  -1.9972699801052749   0.9972743606395355   2.0000000000000000   1.0000000000000000

 
> cat C1???.txt | grep e-21
 
ASS_LOCKIN9_Q 0 21 2      0      0 LP          8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
ASS_LOCKIN9_I 0 21 2      0      0 LP          8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
ASS_LOCKIN7_Q 0 21 2      0      0 LP          8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
ASS_LOCKIN7_I 0 21 2      0      0 LP          8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
ASS_LOCKIN29_Q 1 21 2      0      0 LP50m       8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
ASS_LOCKIN29_I 1 21 2      0      0 LP50m       8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
ASS_LOCKIN27_Q 1 21 2      0      0 LP50m       8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
ASS_LOCKIN27_I 1 21 2      0      0 LP50m       8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
ASS_LOCKIN24_Q 0 21 2      0      0 LP          8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
ASS_LOCKIN24_I 0 21 2      0      0 LP          8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
ASS_LOCKIN22_Q 0 21 2      0      0 LP          8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
ASS_LOCKIN22_I 0 21 2      0      0 LP          8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
ASS_LOCKIN14_Q 1 21 2      0      0 LP50m       8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
ASS_LOCKIN14_I 1 21 2      0      0 LP50m       8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
ASS_LOCKIN12_Q 1 21 2      0      0 LP50m       8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
ASS_LOCKIN12_I 1 21 2      0      0 LP50m       8.448680182849132e-21  -1.9999645699236510   0.9999645702913159   2.0000000000000000   1.0000000000000000
SUS_SRM_SUSSIDE 3 12 4  32768      0 Cheby         8.6572646852632e-21    -1.99726998010527     0.99727436063954     2.00000000000000     1.00000000000000
SUS_PRM_SUSSIDE 3 12 4  32768      0 Cheby         8.6572646852632e-21    -1.99726998010527     0.99727436063954     2.00000000000000     1.00000000000000
 
> cat C1???.txt | grep e-19
 
SUP_MC3_SP_Z_NOISE 1 21 4      0      0 StackVert     1.8769949851031e-19    -1.99887735863559     0.99888848406943     2.00000000000000     1.00000000000000
SUP_MC2_SP_Z_NOISE 1 21 4      0      0 StackVert     1.8769949851031e-19    -1.99887735863559     0.99888848406943     2.00000000000000     1.00000000000000
SUP_MC1_SP_Z_NOISE 1 21 4      0      0 StackVert     1.8769949851031e-19    -1.99887735863559     0.99888848406943     2.00000000000000     1.00000000000000
SUP_MC1_SP_YAW_NOISE 1 21 4      0      0 StackVert     1.8769949851031e-19    -1.99887735863559     0.99888848406943     2.00000000000000     1.00000000000000
SUP_MC1_SP_ROLL_NOISE 1 21 4      0      0 StackVert     1.8769949851031e-19    -1.99887735863559     0.99888848406943     2.00000000000000     1.00000000000000
SUP_MC1_SP_PIT_NOISE 1 21 4      0      0 StackVert     1.8769949851031e-19    -1.99887735863559     0.99888848406943     2.00000000000000     1.00000000000000
SUS_ETMX_LOCKIN1_I 2 21 2      0      0 BTW0.1       1.35175496376953e-19  -1.9999291403672526   0.9999291418378861   2.0000000000000000   1.0000000000000000
SUS_ETMX_LOCKIN1_Q 2 21 2      0      0 BTW0.1       1.35175496376953e-19  -1.9999291403672526   0.9999291418378861   2.0000000000000000   1.0000000000000000
SUS_Z_NOISE_FILT 1 21 4      0      0 StackVert     1.8769949851031e-19    -1.99887735863559     0.99888848406943     2.00000000000000     1.00000000000000
SUS_Z_NOISE_FILT 1 21 4      0      0 StackVert     1.8769949851031e-19    -1.99887735863559     0.99888848406943     2.00000000000000     1.00000000000000
BS_LOCKIN1_Q 2 21 2      0      0 BTW0.1       1.35175496376953e-19  -1.9999291403672526   0.9999291418378861   2.0000000000000000   1.0000000000000000
BS_LOCKIN1_I 2 21 2      0      0 BTW0.1       1.35175496376953e-19  -1.9999291403672526   0.9999291418378861   2.0000000000000000   1.0000000000000000
ITMX_LOCKIN1_Q 2 21 2      0      0 BTW0.1       1.35175496376953e-19  -1.9999291403672526   0.9999291418378861   2.0000000000000000   1.0000000000000000
ITMX_LOCKIN1_I 2 21 2      0      0 BTW0.1       1.35175496376953e-19  -1.9999291403672526   0.9999291418378861   2.0000000000000000   1.0000000000000000
ITMY_LOCKIN1_Q 2 21 2      0      0 BTW0.1       1.35175496376953e-19  -1.9999291403672526   0.9999291418378861   2.0000000000000000   1.0000000000000000
ITMY_LOCKIN1_I 2 21 2      0      0 BTW0.1       1.35175496376953e-19  -1.9999291403672526   0.9999291418378861   2.0000000000000000   1.0000000000000000
PRM_LOCKIN1_Q 2 21 2      0      0 BTW0.1       1.35175496376953e-19  -1.9999291403672526   0.9999291418378861   2.0000000000000000   1.0000000000000000
PRM_LOCKIN1_I 2 21 2      0      0 BTW0.1       1.35175496376953e-19  -1.9999291403672526   0.9999291418378861   2.0000000000000000   1.0000000000000000
SRM_LOCKIN1_Q 2 21 2      0      0 BTW0.1       1.35175496376953e-19  -1.9999291403672526   0.9999291418378861   2.0000000000000000   1.0000000000000000
SRM_LOCKIN1_I 2 21 2      0      0 BTW0.1       1.35175496376953e-19  -1.9999291403672526   0.9999291418378861   2.0000000000000000   1.0000000000000000 
  6071   Mon Dec 5 17:44:41 2011 kiwamuUpdateGeneralmy plan tonight

I am going to try handing off the ALS servo to the IR PDH servo on the Y arm and measure the noise.

 - first I need to investigate why the Y end PDH servo becomes unstable when the ALS is engaged with a high UGF.

 

(some notes)

 So far I still kept failing to increase the UGF of the ALS servo for some reason (see #6024).

Every time when I increased the UGF more then 50 Hz, the Y arm PDH lock became unlocked. It needs an explanation and a solution.

Another thing: During several trials in this evening I found the ETMY_SUSPOS_GAIN had been set to 1, so I reset it to 20, which gives us the damping Q of about 5.

 

(Temperature feedback activated)

 As planed in #6024 I have activated the temperature feedback, so that the PZT control signal is offloaded to the temperature. And it seems working fine.

Currently the gain is set to 0.03, which gives us a time constant of ~30 sec for offloading the control signal.

  6105   Mon Dec 12 11:34:40 2011 Leo SingerSummaryGeneralSome design parameters for a Stewart platform

At the suggestion of Rana and Koji, I have worked out some design parameters for a Stewart platform to be used as a vibration isolation device or as a platform for characterization of suspensions.  I have made some initial guesses about the following design requirements:

  • linear travel: 40 microns peak to peak (based on SOS design requirements in LIGO-T950011)
  • angular travel: 3 mrad peak to peak (based on SOS design requirements in LIGO-T950011)
  • payload mass: 5 kg (wild guess of mass of loaded SOS)
  • payload moment of inertia: 0.01 kg m^2 (wild guess)
  • bandwidth: 500 Hz (suggestion of Rana and Koji: ~kHz)

From these assumptions, I have worked out:

  • peak actuator force: 0.88 kN
  • minimum radius of top platform: 15 cm
  • minimum radius of bottom platform: 30 cm
  • minimum height: 26 cm

The combination of high force, high speed, and ~micron travel limits seems to point to piezoelectric actuators.  PI's model P-225.80 would meet the peak push-pull force requirement, but I have not yet determined if it would meet the bandwidth requirement.  Apparently, typical piezoelectric actuators can exert a greater push force than pull force; wonder if one could use an actuator with a smaller force range than the P-225.80 if the actuator is biased by compression.  (Is this what is meant by a "preloaded" actuator?) 

I have attached a PDF explaining how I worked out the actuator force and platform dimensions.  (I'll try to dice up this PDF and put the contents in the Wiki.)  I also have a plant model in MATLAB with which I have been playing around with control schemes, but I don't think that this is ready to show yet.

Here are some tasks that still remain to be done for this preliminary case study:

  • select sensing technologies: integrated linear encoders and/or strain meters, inertial sensing, optical levers, etc.
  • study joints: Koji and Rana suggest flexures; I need to propose the joint geometry and material
  • study internal modes of the platforms and actuators themselves
  • build noise budget

I'd like to ask for input principally on:

  • appropriateness of my design assumptions
  • piezo actuators currently in use in the lab

 Edit: I also added a Mathematica notebook with the inverse kinematics (mapping from platform state to leg lengths) of the platform. 

 

 

 

 

 

Attachment 1: stewart.pdf
stewart.pdf stewart.pdf stewart.pdf stewart.pdf stewart.pdf stewart.pdf stewart.pdf
Attachment 2: stewart.nb
(* Content-type: application/vnd.wolfram.mathematica *)

(*** Wolfram Notebook File ***)
(* http://www.wolfram.com/nb *)

(* CreatedBy='Mathematica 8.0' *)

(*CacheID: 234*)
(* Internal cache information:
NotebookFileLineBreakTest
... 377 more lines ...
  6143   Wed Dec 21 14:41:22 2011 kiwamuSummaryGeneralminutes of 40m meeting : short-term plan

Here is the Gantt chart we discussed in the 40m meeting today.

Based on the discussions we had, I applied a little bit of corrections on the chart but the main stream remains the same.

40mproject.png

ELOG V3.1.3-