ID |
Date |
Author |
Type |
Category |
Subject |
5810
|
Fri Nov 4 14:18:24 2011 |
MIrko | Update | Adaptive Filtering | Coherence between seismometers and MC length |
Looking into the coherence between the seismometers and IMC length (MC_F):
FIrst with the seismometers only AC filtered at around 0.003 Hz and AA30Hz:
 
Ignore the increase in coherence at very low frequencies. That is an artefact.
Then with an additional filter single complex pole @1Hz Q=1000 (giving 20dB per decade in attenuation above 1Hz) , only for GUR1X:
 |
5809
|
Fri Nov 4 13:53:33 2011 |
Katrin | Update | Green Locking | SHG temperature (YARM) |
Quote:
|
I must confess that I changed the temperature of the laser via the dial yesterday. I believe the initial (displayed) temperature was ~19o, whereas it is now probably in the high 20s. Sorry.
Quote: |
Changing the crystal temperature changes the laser frequency. This will causes the beat note missing at the vertex.
In other words, you will find the beat note at the vertex when the actual temperature of the crystal is reproduced as before,
no matter how the dial setting/temp voltage input is.
|
|
Okay, my elog entry was not clear I changed the temperature of the SHG which only changes the conversion efficiency.
Anyhow, since the laser set temperature and thus the laser frequency has been changed by Zach and I couldn't find a note
of the original laser crystal temperature, my plan is to reset the SHG temperature to the old value, set the laser crystal temperature
around 19°C and do fine adjustment of that temperature by optimising the doubling efficiency. Okay?
|
5808
|
Fri Nov 4 13:13:25 2011 |
Zach | Update | Green Locking | PDH box #17 modified, too |
I also modified the Y-Arm PDH box itself slightly. Previously, there was a flying 10k resistor from the SWEEP input to TP2. I don't see the point of this, so I moved it from TP2 across R19 (to the same point where it is on the gyro PDH boxes) to allow for excitation signals to be injected with the loop closed (i.e., with the SWEEP switch off). This is useful for OLTF measurements. |
5807
|
Fri Nov 4 13:04:50 2011 |
Zach | Update | Green Locking | Passive summing box modifications |
I spent some time the other day trying to diagnose the problem with the Y Arm universal PDH box (S/N 17), which Katrin has been unable to use for locking the green beam. As far as I can tell, there is nothing wrong with the box itself (though the weird TF behavior that Katrin noticed was not initially reproducible, so its cause may still be there).
I did notice that I was unable to generate a PDH error signal using the universal box. In this configuration, a summing circuit is needed to add the PZT modulation signal (fmod = 178875 Hz) in along with the feedback signal. To do this, Katrin was using a slightly different version of the passive summing box that Kiwamu built for the X Arm. I read this entry to understand how it is supposed to work and noticed that the "expected transfer functions" were not what the circuit actually does. I have talked to Kiwamu about it and he found that he posted the wrong TFs (he has the right ones on his computer). As you can see from the plot below, there is extra low passing that severely attenuates the modulation path to the PZT. In addition, there is a phase shift of ~-60 degrees, which is bad.
To combat this, I propose we simply change the resistor in the modulation path from 1M to 10k. This leaves the feedback path TF unchanged, and changes the mod path into a sort of bandpass filter for the modulation frequency. The fact that the phase is near zero at fmod means we don't have to come up with some way to phase shift the signal for demodulation. The attenuation level of ~-36 dB is also convenient: The ZAD-8 mixer wants 7 dBm, so, 10 dBm (FG) - 3 dB (splitter) - 36 dB (sumbox) = -25 dBm ~ 12 mV. This is roughly the desired PZT voltage level.

|
5806
|
Fri Nov 4 05:24:56 2011 |
kiwamu | Update | LSC | offset introcuded in MC and IFO-configure script modified |
[Offsets in MC]
I have introduce an offset in MC2 PIT because the PZT1 again started railing.
Right now the PZT1 EPICS value is within the range happily.
Please keep this MC eigen axis as a nominal configuration.
[IFO-configure script]
I have modified the IFO configure scripts such that XARM and YARM are locked with POX11 and POY11 respectively.
A big advantage in use of POX and POY is that we don't need to misalign ITMs when we align each arm.
Those scripts are now available from the C1IFO_CONFIGURE screen as usual. |
5805
|
Fri Nov 4 00:25:49 2011 |
Zach | Update | SUS | Dr. SUS paths updated--question of human oversight remains |
- I have replaced all instances of /cvs/cds/rtcds with /opt/rtcds in the Dr. SUS code.

- We discussed placing a human in charge of whether or not the input matrices get written to the frontend. I am not sure if we reached a definitive conclusion. Currently, the code is set to write the matrices automatically. What to do?
- If we decide that oversight is necessary, I suggest that we leave the publishing of the results to the elog intact. This way, it will be someone's job to read the weekly Dr. SUS diagnosis on Sunday night (or Monday morning), and run a simple script that writes the matrices. This seems like the most reasonable solution.
I await responses... |
5804
|
Fri Nov 4 00:13:24 2011 |
Koji | Update | LSC | XARM locked with POX11 |
XARM lock was achieved by POX11_I
Summary:
- The whitening gains of POX11_I and Q are 42dB so that POX11_I have the same amplitude as AS55_I
- The demod phase of POX11 was adjusted to eliminate the PDH signal from the Q phase. The phase is -100.5deg.
- In order to lock the XARM with POX11_I_ERR, I had to increase the trigger threshold from 0.1 to 0.2 as the arm was
kicked with the threshold of 0.1.
Method
- Lock the X arm with AS55_I at the XARM configuration.
- Adjusted POX11 demod phase so that POX11_Q is minimized.
- POX I&Q whitening gains were adjusted. When they are 42dB, POX11_I_ERR and AS55_I_ERR have almost the same signal amplitude.
(In reality, POX11_I_ERR has +1dB larger amplitude.)
- Adjusted POX11 demod phase again with better precision.
- Measured transfer function between AS55_I_ERR and POX11_I_ERR. As the sign was opposite, the demod phase was -180deg flipped.
- Tried to lock the arm with POX11_I_ERR. It did not acquire the lock. The arm looked kicked by the servo.
- Increased the trigger threshold from 0.1 to 0.2. Now the arm is locked with POX11_I_ERR. |
Attachment 1: POX11.pdf
|
|
5803
|
Thu Nov 3 22:32:48 2011 |
Suresh | Update | IOO | MC realigned to center the spots on actuation nodes |
Quote: |
Several activities in the past week (elog1, Mirko's rough realignment of MC and adjustment of the PSL zig-zag on Monday and elog2 ), had led to an MC state where the spots were not centered on the actuation nodes.
The change in the C1IOO model part dealing with MC_ASS led to the disappearance of all MC_ASS filter definitions in the lockins. I have fixed all that, remade the screens and scripts for making the MC Decenter measurements.
I have just completed the re-centering of the spots on the MC and this of course will lead to some change in the input pointing.
The MC_REFL beam also was recented on the WFS and the MC2_TRANS QPD.
Will add the mc-decenter measurement in a few mins
|
The current MC spot decentering is given below:
spot positions in mm:
MC1P MC2P MC3P MC1Y MC2Y MC3Y
0.4089 0.4800 -0.1266 -1.4095 0.3808 -1.7517
The yaw measurement probably has the wrong scale factor in the conversion to mm. It could be under estimated by a factor 2.65/2.00 since the 10% step in coil gains produces a 2mm offset rather than the expected 2.65mm. See the figures below. I will check this during the next iteration when another mode clearner alignment comes up.
As I had to redefine all the MC_ASS lockin filters it is possible that Lockin phase might have changed by a few degrees giving rise to a change in the scale factor.

|
5802
|
Thu Nov 3 19:58:18 2011 |
kiwamu | Update | LSC | POX11 demod board : modification done |
The modification on the POX11 demod board has been successfully done.
I followed the procedure which had been posted in a past entry (#4554).
The home-made splitter was replaced by PSCQ-2-51W, which has a relatively wide band of 5 - 50 MHz.
The usual orthogonality adjustment will be done in the daytime.
The attached snapshot was taken when an sinusoidal RF signal with a slight frequency offset from LO was injected to the RF input.
It is clear that the I and Q output show healthy signals (i.e. almost the same amplitude and 90 deg phase difference.)

Quote from #5801 |
I am going to replace the splitter which had been made with a hand-wounded coil because it can work only at a specific tailored frequency.
|
|
5801
|
Thu Nov 3 18:41:36 2011 |
kiwamu | Update | LSC | POX11 demod board : haven't been modified yet |
I pulled out the POX11 demod board and found the power splitter on the board hadn't been modified yet.
I am going to replace the splitter which had been made with a hand-wounded coil because it can work only at a specific tailored frequency.
Quote from #5753 |
The POX11 demodulation board is broken
|
|
5800
|
Thu Nov 3 17:24:59 2011 |
Zach | Update | Green Locking | SHG temperature (YARM) |
I must confess that I changed the temperature of the laser via the dial yesterday. I believe the initial (displayed) temperature was ~19o, whereas it is now probably in the high 20s. Sorry.
Quote: |
Changing the crystal temperature changes the laser frequency. This will causes the beat note missing at the vertex.
In other words, you will find the beat note at the vertex when the actual temperature of the crystal is reproduced as before,
no matter how the dial setting/temp voltage input is.
|
|
5799
|
Thu Nov 3 17:19:54 2011 |
Suresh | Update | IOO | MC realigned to center the spots on actuation nodes |
Several activities in the past week (elog1, Mirko's rough realignment of MC and adjustment of the PSL zig-zag on Monday and elog2 ), had led to an MC state where the spots were not centered on the actuation nodes.
The change in the C1IOO model part dealing with MC_ASS led to the disappearance of all MC_ASS filter definitions in the lockins. I have fixed all that, remade the screens and scripts for making the MC Decenter measurements.
I have just completed the re-centering of the spots on the MC and this of course will lead to some change in the input pointing.
The MC_REFL beam also was recented on the WFS and the MC2_TRANS QPD.
Will add the mc-decenter measurement in a few mins |
5798
|
Thu Nov 3 17:04:23 2011 |
Koji | Update | Green Locking | SHG temperature (YARM) |
Changing the crystal temperature changes the laser frequency. This will causes the beat note missing at the vertex.
In other words, you will find the beat note at the vertex when the actual temperature of the crystal is reproduced as before,
no matter how the dial setting/temp voltage input is. |
5797
|
Thu Nov 3 16:43:44 2011 |
Katrin | Update | Green Locking | SHG temperature (YARM) |
Plugging in the thermal feedback BNC cable to the laser reduced the DC voltage of the green PDH photo diode from 3.12 V to 1.5V off resonance.
The power emitted by the laser was the same as in the case without that cable. Note LT, i.e. measured crystal temperature, of the laser show a
different value when the BNC is connected, but the manual clearly states that this display does not work properly if a cable is connected to the
slow BNC plug, an offset is added.
The power of the 532nm light behind the SHG oven has been reduced from 1mW to 0.4mW. I changed the crystal temperature such that the power
of the green light is 1mW. With this new temperature setting the laser can be locked again.
|
w/o BNC cable at slow plug |
w/ BNC cable at slow plug |
T (°C) |
29.776 |
29.776 |
LT (°C) |
39.2 |
48.4 |
1064nm power (mW) |
440 |
448 |
Temp. at TC200 (°C) |
35.7 |
36.4 |
532nm power in front of Isolator (mW) |
1.0 |
1.0 |
|
5796
|
Thu Nov 3 16:31:47 2011 |
kiwamu | Update | LSC | PDA10CF as POP22/110 : better |
The POP22/110 RFPD has been replaced by PDA10CF. As a result the 22 and 110 MHz signals became detectable.
However the signal level maybe too low according to a quick look with an RF spectrum analyzer.
The level at 22 and 110 MHz were both approximately -70 dBm although these values were measured when the central part was freely swinging.
Perhaps we need to amplify the signals depending on the actual SNR.
Also I have updated the optical tables' wiki page :
http://blue.ligo-wa.caltech.edu:8000/40m/Optical_Tables
Quote from #5794 |
I will replace it by PDA10CF, which is made from InGaAs and supposed to have 10 times bigger responsibility.
|
|
5795
|
Thu Nov 3 15:14:22 2011 |
Koji | Update | CDS | CSS/BOY installed on pianosa |
How to run/use CSS/BOY
(PREPARATION)
0) Everything runs on pianosa for now.
1) type css to launch CSS IDE.
2) You may want to create your own project folder as generally everything happens below this folder.
=== How to make a new project ===
- Right-click on tree view of Navigator pane
- You are asked to select a wizard. Select "General -> Project". Click "Next".
- Type in an appropriate project name (like KOJI). Click "Finish"
- The actual location of the project is /home/controls/CSS-Workspaces/Default/KOJI/ in the above example
(PLAY WITH "Data Browser", THE STRIPTOOL ALTERNATIVE)
1) Select the menu "CSS -> Trends -> Data Browser". A new data browser window appears.
2) Right-click on the data browser window. Select the menu "Add PV". Type in the channel name (e.g. "C1:LSC-ASDC_OUT16")
3) Once the plot configuration is completed, it can be saved as a template. Select the menu "File -> Save" and put it in your project folder.
4) Everything else is relatively straightforward. You can add multiple channels. Log scaling is also available.
I still don't find how to split the vertical axis to make a stacked charts, but I don't surprise even if it is not available.

(HOW TO MAKE A NEW "BOY" SCREEN)
0) Simply to say BOY is the alternative of MEDM. The screen file of BOY is named as "*.opi " similar to "*.adl " for MEDM.
1) To create a new opi file, right-click on the navigator tree and select the menu "New -> Other".
2) You are asked to select a wizard. Select "BOY -> OPI file" and click "Next".
3) Type in the name of the opi file. Also select the location of the file in the project tree. Click "Finish".
4) Now you are in OPI EDITOR. Place your widgets as you like.
5) To test the OPI screen, push the green round button at the top right. The short cut key is "CTRL-G".

(HOW TO EDIT AN EXISTING OPI FILE)
1) Right click an OPI file in the navigator tree. Select the menu "Open WIth -> OPI Editor". That's it.
(HOW TO CONVERT AN EXISTING ADL FILE INTO OPI FILE)
1) You need to copy your ADL file into your project folder. In this example, it is /home/controls/CSS-Workspaces/Default/KOJI/
2) Once the ADL file is in the project folder, it should appear in the navigator tree. If not, right-click the navigator pane and select "Refresh".
3) Make sure "ADL Parser" button at the left top part is selected, although this has no essential function.
This button just changes the window layout and does nothing. But the ADL Tree View pane would be interesting to see.
3) If you select the ADL file by clicking it,the tree structure of the ADL file is automatically interpreted and appears in the ADL Tree View pane.
But it is just a display and does nothing.
4) Right-click the ADL file in the navigator pane. Now you can see the new menu "BOY". Select "BOY -> Convert ADL File to OPI".
5) Now you get the opi version of that file.
The conversion is not perfect as we can imagine. It works fine for the simple screens. (e.g. matrix screens)
But the filter module screens get wierd. And the new LSC screen did not work properly (maybe too heavy?)

(HOW TO RUN OUR SHELL/PERL/PYTHON SCRIPTS FROM BOY)
CSS has javascript/python scripting capability.
I suspect that we can make a wrapper to run external commands from python script although it is not obvious yet. |
5794
|
Thu Nov 3 14:25:52 2011 |
kiwamu | Update | LSC | PDA10A as POP22/110 : too small signal |
It turned out that the signal was too small with PDA10A to detect the 22 and 110 MHz RF sidebands.
The DC output coming out from it was about half mV or so (corresponding to few uW in laser power) when the PRCL was locked to the carrier.
This is because PDA10A is a silicon detector which is more sensitive to visible light than IR.
The reason we chose PDA10A was that it has relatively a large diode size of 1 mm in diameter.
However according to the data sheet the responsibility at 1064 nm is about 0.05 A/W which is sad.
I will replace it by PDA10CF, which is made from InGaAs and supposed to have 10 times bigger responsibility.
Though the diode size will be half mm in diameter, which may require another strong lens in front of it.
Quote from #5788 |
The POP22/110 RFPD has been installed. It is PDA10A from Thorlabs instead of the usual home-made RFPD.
+ Fine alignment
|
|
5793
|
Thu Nov 3 13:00:52 2011 |
Jenne | Update | Photos | Formatting of MEDM screen names |
Quote: |
After lots of trial and error, and a little inspiration from Koji, I have written a new script that will run when you select "update snapshot" in the yellow ! button on any MEDM screen.
Right now, it's only live for the OAF_OVERVIEW screen. View snapshot and view prev snapshot also work.
Next on the list is to make a script that will create the yellow buttons for each screen, so I don't have to type millions of things in by hand.
The script lives in: /cvs/cds/rtcds/caltech/c1/scripts/MEDMsnapshots, and it's called....wait for it....... "updatesnap".
|
Currently the update snapshot script looks at the 3 letters after "C1" to determine what folder to put the snapshots in. (It can also handle the case when there is no C1, ex. OAF_OVERVIEW.adl still goes to the c1oaf folder). If the 3 letters after C1 are SYS, then it puts the snapshot into /opt/rtcds/caltech/c1/medm/c1sys/snap/MEDM_SCREEN_NAME.adl
Mostly this is totally okay, but a few subsystems seem to have incongruous names. For example, there are screens called "C1ALS...." in the c1gcv folder. Is it okay if these snapshots go into a /c1als/snap folder, or do I need to figure out how to put them in the exact same folder they currently exist in? Or, perhaps, why aren't they just in a c1als folder to begin with? It seems like we just weren't careful when organizing these screens.
Another problem one is the C1_FE_STATUS.adl screen. Can I create a c1gds folder, and rename that screen to C1GDS_FE_STATUS.adl? Objections?
|
5792
|
Wed Nov 2 22:02:39 2011 |
Jenne | Update | Photos | New screen snapshot script written! |
After lots of trial and error, and a little inspiration from Koji, I have written a new script that will run when you select "update snapshot" in the yellow ! button on any MEDM screen.
Right now, it's only live for the OAF_OVERVIEW screen. View snapshot and view prev snapshot also work.
Next on the list is to make a script that will create the yellow buttons for each screen, so I don't have to type millions of things in by hand.
The script lives in: /cvs/cds/rtcds/caltech/c1/scripts/MEDMsnapshots, and it's called....wait for it....... "updatesnap".
|
5791
|
Wed Nov 2 21:49:59 2011 |
Katrin | Update | CDS | c1iscey computer died again |
while I was not doing anything on the machine. |
5790
|
Wed Nov 2 21:15:06 2011 |
Katrin | Update | CDS | and again c1scy.mdl compiled |
I changed an ADC channel for GCY_ERR and thus recompiled the c1scy model. |
5789
|
Wed Nov 2 20:56:49 2011 |
Katrin | Update | CDS | digital zeros at C1:X05-MADC0 (c1scy) |
Channels C1:X05-MADC0_TP_XXX with XXX 2-9, 14-19, 21-27, 29-31 showed digital zeros.
Some of these channels are used in c1scy.mdl, e.g. for OSEM stuff. I guess this is not optimal... |
5788
|
Wed Nov 2 19:32:20 2011 |
kiwamu | Update | LSC | POP22/110 installed |
[Steve / Kiwamu]
The POP22/110 RFPD has been installed. It is PDA10A from Thorlabs instead of the usual home-made RFPD.
For an RF cable we rerouted one of the spare Heliax cables for it.
The cable is the one which used to be served for the 166MHz ASC wavefront sensors, picking up the RF source signal at 1X2 and sending it to the LSC rack.
- - Remaining tasks - -
+ Fine alignment
+ Connection at the LSC rack
+ Update of the table diagram
Quote from #5783 |
They were traced and labeled. One goes to 1X2 and the other to AS-ISCT. They are Andrew Heliax 1/4" od. made by CommScone, model number FSJ1-50A
|
|
5787
|
Wed Nov 2 17:33:28 2011 |
Katrin | Update | Green Locking | ADC channels for slow control |
connector J9B of hardware ADC --> ch1 in software ADC --> GCY_ERR
connector J14 of hardware ADC --> ch11 in software ADC --> GCY_PZT
connector J15 of hardware ADC --> ch13 in software ADC --> GCY_REFL_DC
|
5786
|
Wed Nov 2 17:29:10 2011 |
Katrin | Update | CDS | c1scy.mdl compiled |
Slight modification on that model:
- terminated Q_out of Lockins to be able to compile the old model
- assigned other ADC channels to GCY (green YARM)
|
5785
|
Wed Nov 2 14:07:25 2011 |
Zach | Update | elog | restarted |
Elog was hanging, restarted with the script. |
5784
|
Wed Nov 2 11:29:04 2011 |
not Zach | Update | SUS | "Dr. SUS" progress |
Quote: |
Now that NDS2 is working, I was able to run all parts of diagAllSUS (except for the matrix writing) without errors. Barring issues with standard commands (freeswing, turnOnWatchDogs.csh, caput, etc.), Dr. SUS should be ready to go.
As requested, I have suppressed the generation of an elog post containing the results of the diagonalization.
Dr. SUS will run on allegra as a cron job at 8:00am on Sundays:
allegra:peakFit>crontab -l
PATH=/bin/:/usr/bin/:/cvs/cds/caltech/apps/linux64/matlab/bin/:/cvs/cds/caltech/apps/linux/gds/bin/:/cvs/cds/caltech/apps/linux/tds/bin/
PWD=/cvs/cds/caltech/apps/linux/gds/lib/
LD_LIBRARY_PATH=/cvs/cds/caltech/apps/linux/gds/lib
01 05 * * 0 cat /cvs/cds/caltech/users/kiwamu/work/20091026_OMC-LSC-diag/src/OMC_LSC_timing.m | matlab -nosplash -nodesktop > /dev/null
0 8 * * 0 /cvs/cds/rtcds/caltech/c1/scripts/SUS/peakFit/runDrSUS
Also: should these variable definitions really be here?
|
Cron starts with only a very minimal PATH. However, this shouldn't be an issue if you specify the full path to the commands.
The rest of the env vars should probably not be there.
Also, Zach: using /cvs/cds is now forbidden. We need to put this script in the right place. |
5783
|
Wed Nov 2 10:41:47 2011 |
steve | Update | General | 2 spare heliax at the LSC rack |
They were traced and labeled. One goes to 1X2 and the other to AS-ISCT. They are Andrew Heliax 1/4" od. made by CommScone, model number FSJ1-50A |
5782
|
Wed Nov 2 10:04:05 2011 |
steve | Update | SUS | MC2 chamber anchoring tightened |
Quote: |
Thinks to do before the NEXT realignment:
B, tie 4 ancher bolts on table legs to the floor
C, tie 4 dog clamps between table and chamber
D, check the locked position of the 4 x 4 positioning screws
E, check bellow protecting 4 tubes are not shorting
A, here is the concrete slab cut
It reminds me to check the IFO vacuum envelope dog clamps on the chambers to floor with torque wrench.
|
I locked the PMC and MC resonated in TM00 right on. Than I started checking anchoring screws with the torque wrench.
B, 3/8 foor bolts were tight, They were set to 50 ft/lbs
C, dog clamp bolts were tight at 80 ft/lbs
D, horizontal position locks were lose. They were locked by finger.
E, below covers were reset not to short
The MC is locking in TM01 mode now |
5781
|
Wed Nov 2 01:53:08 2011 |
Zach | Update | SUS | "Dr. SUS" progress |
Now that NDS2 is working, I was able to run all parts of diagAllSUS (except for the matrix writing) without errors. Barring issues with standard commands (freeswing, turnOnWatchDogs.csh, caput, etc.), Dr. SUS should be ready to go.
As requested, I have suppressed the generation of an elog post containing the results of the diagonalization.
Dr. SUS will run on allegra as a cron job at 8:00am on Sundays:
allegra:peakFit>crontab -l
PATH=/bin/:/usr/bin/:/cvs/cds/caltech/apps/linux64/matlab/bin/:/cvs/cds/caltech/apps/linux/gds/bin/:/cvs/cds/caltech/apps/linux/tds/bin/
PWD=/cvs/cds/caltech/apps/linux/gds/lib/
LD_LIBRARY_PATH=/cvs/cds/caltech/apps/linux/gds/lib
01 05 * * 0 cat /cvs/cds/caltech/users/kiwamu/work/20091026_OMC-LSC-diag/src/OMC_LSC_timing.m | matlab -nosplash -nodesktop > /dev/null
0 8 * * 0 /cvs/cds/rtcds/caltech/c1/scripts/SUS/peakFit/runDrSUS
Also: should these variable definitions really be here?
|
5780
|
Tue Nov 1 23:13:28 2011 |
Zach | Update | Computers | NDS2 channel files |
I did some messing around with the NDS2 config and channel files and things seem to be working as expected... for now. SENSOR channel data can be acquired for all sensors on all hanging optics.
What I did:
- NDS2 gets its channel lists from .../users/jzweizig/nds2-mafalda/nds2.conf, which is called in the start-nds2 script. Within this, there are channel.file lines that specify which channels are available for raw and trend data. The four files that were listed were:
- C-R-raw-channel_list.txt
- C-M-ChanList.txt
- C-T-ChanLIst.txt
- C-R-online-channel_list.txt (this one was listed after a hashed line, which was suspicous---see below)
- I noticed that a grep for SENSOR only returned lines for non-MC mirrors in both "R" files
- I also noticed that calling NDS2_GetChannels('mafalda.martian:31200') did not return any non-suffixed (i.e., raw) channel names for MCx_SENSOR channels, while non-MC SENSOR channels each had two non-suffixed listings. I thought this was strange.
- I manually added the line "C1:SUS-MC1_SENSOR_UL 0 real_4 2048 C-R" to one of the "R" channel files, then restarted the NDS2 server, and that channel was still not served. I figured that the second "R" channel file might have been left in the config file as a mistake, so I commented it out, restarted the NDS2 server, and was able to get MC1_SENSOR_UL data. I have left the comment-out there, with a signed EDIT.
- Wary of (and too lazy to) manually add lines for all 5 sensors for each MC mirror, I decided to try generating a channel file using the most recent .gwf file in the frames, as indicated in Joe and John's elog post. To do this, while in .../nds2-mafalda/, I ran:
- /cvs/cds/caltech/users/jzweizig/nds2-server/bin/buildChannelList /frames/full/10042/C-R-1004246528-16.gwf > C-R-raw-channel_list.txt
- A grep for SENSOR in the new C-R-raw-channel_list.txt now returned lines for all MC mirror sensors... BUT NOT FOR ETMY(?!). I tried some slightly older .gwf files (all from today), but the ETMY files never showed up. I had no choice but to enter them manually. Another odd thing is that the channel file generated this way seems to be fairly jumbled up, in the sense that there is no clear top-town order (e.g. SUS-BS_blah then SUS-ETMX_blah). Instead, some SUS-BS channels are here, some are after SUS-ETMX or SUS-PRM channels, etc. Look at the file to know what I mean.
- The original raw channel file is there as C-R-raw-channel_list.txt.bak.1004247481.
In any case, as I said, everything appears to be working now, but as soon as we try to generate a new channel file using the prescribed means, there will inevitably be channels omitted. Someone who knows more than me should get to the bottom of this and wiki a strict, detailed procedure for how this is to be done. |
5779
|
Tue Nov 1 19:26:38 2011 |
Zach | Update | SUS | "Dr. SUS" progress |
EDIT: Ran Jamie's NDS2 reset method and it's still not serving up MC data.
I am debugging the SUS input matrix diagonalization code (which I have affectionately termed "Dr. SUS") offline by running everything except the actual writing of the matrices (%writeSUSinmat()) in a sandbox directory. Some notes:
- nodus doesn't know NDS2, but this isn't a problem given Kiwamu's reply, since we don't want to push results to the elog. I will still have the script push "optics kicked---don't touch" alerts to the elog, but I realized this can be done easily from a remote computer via in-script SSH commands. My next choice was pianosa, but even though she knows NDS2, she spits out MEX errors when I try to get data. Third stop was allegra, and she plays nice

- NDS2 is unable to read the MC mirror sensor data. Data from all other optics are retrieved without a problem. I verified that raw data was being written by plotting playback data in dataviewer, and I tried various times and the problem persisted. I suspect the problem is on the NDS2 server side:
The most recent entry in .../users/jzweizig/nds2-mafalda/channel_history shows nothing for MC1 2 or 3
mafalda:channel_history>more C-R-999986048-178368.cls | grep SENSOR
C1:SUS-BS_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-BS_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-BS_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-BS_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-BS_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-ETMX_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-ETMX_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-ETMX_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-ETMX_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-ETMX_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-ETMY_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-ETMY_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-ETMY_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-ETMY_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-ETMY_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-ITMX_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-ITMX_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-ITMX_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-ITMX_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-ITMX_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-ITMY_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-ITMY_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-ITMY_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-ITMY_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-ITMY_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-PRM_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-PRM_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-PRM_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-PRM_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-PRM_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-SRM_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-SRM_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-SRM_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-SRM_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-SRM_SENSOR_UR raw 0 real_4 2048 C-R
|
5778
|
Tue Nov 1 18:45:48 2011 |
Jenne | Update | Computers | Allegra's screens |
I was trying to give Allegra a second head, and it didn't quite work. It's still in progress. Steve, you might not like how I've 'mounted' the second monitor, so we can talk about something that might work tomorrow. |
5777
|
Tue Nov 1 18:16:50 2011 |
Den | Update | Adaptive Filtering | Adaptive filter witness and EP SNR |
Quote: |
Coherence of seismometers to MCL:
STS1 is located at the vertex. x-axis along the x arm.
GUR1 is located at the IMC MC2 mirror. Same orientation.

=> 1. Only the x-direction has good coherence (to be expected)
2. Only good coherence at 1.5-4Hz (huh?)
So probably other noise sources are dominating. Let's look into noise projections. Remember IMC autoalignment is off.
A quick adaptive filter run with only the GUR1 and STS1 witnesses applied only to MCL didn't really do anything. Some more thought needs to be invested into the AA and shaping filters.
|
The possible explanation to this effect is the following:
Seismic noise mainly consists of the Love and Rayleigh surface waves. In the simulations we've taken 2 perpendicular Love waves and 2 perpendicular Rayleigh waves that interfere under the test mirrors. This interference produces both translational and tilt movements. Then we can see the coherence between translational motion and cavity length.

1. The coherence at big frequencies is small due to the passive isolation.
2. The coherence at 1 Hz is 0 due to the wire resonance.
3. The coherence between 1 and 10 Hz is reasonable. At the real 40m's measurements we can see only good coherence for gur1_x and sts1_x but this is the matter of adjusting seismic waves amplitude and direction. In the simulation we've assumed that all waves are of the same amplitude. The really interesting thing is that
4. The coherence below 0.8 Hz began to grow. We don't see this in real measurements.
But let's simulate the seismometer measurements. It measures not only translational motion but also tilt and with amplitude proportional to g / omega^2. On the Figure below the spectrum of translation motion, tilt and tilt as seen by seismometer is presented. We can see that at low frequencies tilt begins to dominate over the translational motion. We assumed the speed of waves in the region 30 - 60 m/sec.

Let's now plot the coherence between the cavity length and seismometer signal.

We can see that the coherence between seismic signal from measured by seismometer and cavity length is gone below 1 Hz where tilt becomes important.
Now let's try to filter out the seismic noise from the cavity length using both static Wiener filtering and adaptive Mfxlms algorithm. For both filters we've used AA filter before the filters and also AI filter after adaptive filter. The downsampling ratio was 4, the sample frequency 256. We can see that nothing is really subtracted due to the pollution of the seismometer signal due to tilt motion.

Assume we do the same computational experiment but with the seismometers that measure only ground translational motion and tilt do not affect on them. Then we have a reasonable subraction of seismic noise at low frequencies even with the filters of the length 100 as shown on the figure below.

Let's look through an order of magnitude analysis. Assume ground motion consists of only one wave with amplitude A and only vertical movement: z(t) = A*sin(2 pi 0.1 t). So the frequency of the wave is 0.1 Hz. If A = 10-6 m => the amplitude of the suspended mirror motion is also approximately 10-6 m, as we have no isolation at low frequencies. The tilt angle has the amplitude alpha = 2*pi*A/lambda, where lambda - wavelength of the ground wave, lambda = v/f = 40/0.1 = 400 m, v - speed of the wave, f - frequency. Then alpha = 10-8 rad. If the distance between ground and mirror suspension point is 1 m, then mirror motion amplitude due to tilt is B = 10-8 m << A.
It turns out that tilt does not effect much on the cavity length compared to the ground translational motion, but it affects a lot on the seismometer signals, that are used as witness signals in the filtering. For that reason we need tiltmeters to filter seismometer signals in order to obtain pure translational ground motion. |
5776
|
Tue Nov 1 16:02:15 2011 |
kiwamu | Update | SUS | Re: SUS input matrix diagonalizer REMOVED from crontab |
Quote: |
It turns out that nodus doesn't know how to NDS2, so I can't run diagAllSUS as a cron job on nodus. To further complicate things, no other machines can run the elog utility, so I am going to have to do something shifty...
|
Actually in the last 40m meeting we discussed the SUS diagnosis and decided not to post the results on the elog.
Alternatively we will have a summary web page which will contain all the information (sensitivity, UGF monitors, etc.,) and will be updated everyday like GEO.
This will be a place where we should post the SUS results every week.
So we don't need to worry about the cron-elog job, and for running the scripts you can simply use one of the lab machines as a cron host.
Once you get the scripts running on a machine as a cron job, it will be the point where we should quit developing the SUS diagonalizer and pass it to the web summary people. |
5775
|
Tue Nov 1 13:46:03 2011 |
Zach | Update | SUS | SUS input matrix diagonalizer REMOVED from crontab |
It turns out that nodus doesn't know how to NDS2, so I can't run diagAllSUS as a cron job on nodus. To further complicate things, no other machines can run the elog utility, so I am going to have to do something shifty... |
5774
|
Tue Nov 1 13:41:38 2011 |
Mirko | Update | LSC | AM modulation due to non-optimal SB frequency |
Quote: |
[Kiwamu, Mirko]
Non-optimal 11MHz SB frequency causes PM to be transformed into AM.
m_AM / m_PM = 4039 * 1kHz / df , with df beeing the amount the SB freq. is off.
Someone might want to double check ths.
|
Actually there was an error.
For 11MHz it is:
m_AM / m_PM = 2228 * 1kHz / df
For 55MHz:
m_AM / m_PM = 99.80 * 1kHz / df
see PDF |
Attachment 1: IMC.pdf
|
|
5773
|
Mon Oct 31 21:46:32 2011 |
kiwamu | Update | LSC | Dependence of Recycling gain on incident beam pointing |
I horizontally swept the translation of the incident beam in order to investigate a possible clipping in Power-recycled Michelson (PRMI).
The recycling gain of PRMI depended on the beam pointing but it did't improve the recycling gain.
I guess the amount of the entire shift I introduced was about +/- the beam diameter = +/- 5 mm or so.
Within the range of about +/- 5mm in the horizontal beam translation I didn't find any obvious sign of a clipping.
(Measurement)
This is the procedure which I did:
(1) Some amount of offsets were introduced on MC2 in both PIT and YAW such that the PZT1 won't rail ( #5762).
=> Every time when I introduced the offset I realigned the zig-zag mirrors on the PSL table to maintain the high transmissivity of MC.
(2) Fine tuning of the MC offsets so that the PZT1_X EPICS value becomes almost zero when the beam is aligned down to the Y arm.
=> 0.523 in C1:ASC_PZT1_X became a point where the coupling of the beam into the Y arm was maximized.
=> Last time the direction which we investigated was the positive side from this zero point ( #5709) in PZT1_X.
(3) Aligned MICH by steering BS.
(4) Locked PRMI with carrier resonating and aligned PRM to maximized the power recycling gain which was obtained from POYDC.
(5) Translated the beam pointing
=> First I shifted PZT1_X by a wanted amount.
=> Then I locked the Y arm and realigned PZT2_X by maximizing the Y arm transmission.
This procedure should give us a pure translation on the incident beam.
(6) Repeated the same procedure (3) through (5) in each PZT1 position.
(Results)
Here shows the measured recycling gain and the power reflectivity of PRMI as a function of the beam pointing.

Upper plot : measured recycling gains (Red) observed maximum values (Black) measured values on average.
Lower plot : measured power reflectivity of PRMI (Blue) observed minimum values (Black) measured values on average.
As shown in the plots the recycling gain could go up to 8 at some points.
As the PZT went away from 0 it decreased and eventually became about 3 in each side.
The reflectivity showed the minimum value of 0.4 when the PZT1 was at -1 in EPICS value.
One hypothesis to explain this plot can be that : we are just seeing the effect of the incident beam misalignment.
|
5772
|
Mon Oct 31 19:39:00 2011 |
Jenne | Update | Adaptive Filtering | Screens, code, computers |
[Mirko, Jenne]
I finished (mostly? maybe?) the OAF screens. They're pretty awesome.
While we were playing with the OAF, trying to do some oafing, the output of the code decided to just be zeros. We did a test, and in the c-code set the output to be a constant value, and that worked. But when we put it back to normal (being adaptive) and recompiled, it still only outputs zeros. The code is receiving both witness and error signals, so we don't know what's going on.
In the course of trying to make things work again, we did a complete reboot of c1lsc and c1sus. Did a burt restore. Everything (except our weird code problem) should be fine again. Optics are damping happily. |
5771
|
Mon Oct 31 15:58:25 2011 |
steve | Update | SUS | thinking of black glass baffles for 40m |
Shade 12 black glass-green lines: 1/8" thick, 6" wide x 7 " high mounted on angle bracket below. Aperture 1" diameter. Let me know what do you think.
|
Attachment 1: 03260901.PDF
|
|
Attachment 2: 03260902.PDF
|
|
5770
|
Mon Oct 31 14:06:16 2011 |
Zach | Update | SUS | SUS input matrix diagonalizer added to crontab |
I actually tried to do this last night, but I was getting a terminal error from nodus. Jamie told me to just manually redefine the TERM variable and it would work. So, I have added kickAll and diagAllSUS to controls@nodus's crontab:
nodus:~>crontab -l
0 5 * * * /opt/rtcds/caltech/c1/scripts/backup/rsync.backup
0 7 * * * /opt/rtcds/caltech/c1/scripts/backup/check_backup.sh
0 17 * * 0 /cvs/cds/caltech/users/jenne/LIGOX/LIGOX_Pizza_Reminders.sh
0 8 * * 0 /cvs/cds/rtcds/caltech/c1/scripts/SUS/peakFit/kickAll
0 18 * * 0 /cvs/cds/rtcds/caltech/c1/scripts/SUS/peakFit/diagAllSUS
Again, their functionality should be checked before this is allowed to run on Sunday!
|
5769
|
Mon Oct 31 14:01:56 2011 |
Katrin | Update | Green Locking | YARM locks for 2h |
Today, I could lock the YARM laser for 2h to the YARM cavity. After to hours the output of the servo is saturated. I need to work on thermal feedback to the laser.
It is a nice TEM00 mode and the green light enters PSL table.

Measured with pin-ball machine spectrum analyzer (I forgot the real name, but it is the one that makes sounds like a pin-ball machine), source power10mVp, Lb1005 gain 2.05.
Setup

Input offset of LB1005 is zero
Locking history
On Thursday, Oct 27, lock for 3 min
On Friday, Oct 28, lock up to 18 min, improvements done by
- finding the right adjustment of PI Corner frequency and gain
- better alignment of the light to the cavity
- I used a high-pass filter between LO and LB1005, but no improvement of lock. In contrast, it got worse.
On Monday,Oct 31, careful adjustment of summing box (rear of of LB1005), lock up to 2h, limited by saturated feedback signal --> work on slow control
Some more plots



|
Attachment 1: 20111031_OLTF.png
|
|
Attachment 2: YARM_setup.png
|
|
5768
|
Mon Oct 31 09:42:12 2011 |
steve | Update | IOO | PMC locked |
The PMC HV drops off more offen lately. |
Attachment 1: pmcHV.png
|
|
5767
|
Mon Oct 31 08:55:19 2011 |
steve | Update | VAC | pressure plot at day 53 |
Quote: |
I was lucky to notice that the nitrogen supply line to the vacuum valves was leaking. Closed ALL valves. Open supply line to atm. Fixed leak.
This was done fast so the pumps did not have to be shut down. Pressurized supply line and open valves to
"Vac Normal" condition in the right sequence.
|
|
Attachment 1: pd71-m-d53.png
|
|
5766
|
Sun Oct 30 23:03:37 2011 |
SUS_Diagonalizer | Update | SUS | SUS input matrix diagonalization complete (EXAMPLE) |
New SUS input matrix diagonalization complete. Matrices have been written to the frontend. Summaries for each optic can be viewed below.
(THIS IS AN EXAMPLE---no new matrices have been written.) |
Attachment 1: MC1.png
|
|
Attachment 2: MC2.png
|
|
Attachment 3: MC3.png
|
|
Attachment 4: ETMX.png
|
|
Attachment 5: ETMY.png
|
|
Attachment 6: ITMX.png
|
|
Attachment 7: ITMY.png
|
|
Attachment 8: PRM.png
|
|
Attachment 9: SRM.png
|
|
Attachment 10: BS.png
|
|
5765
|
Sun Oct 30 23:01:51 2011 |
Zach | Update | SUS | diagAllSUS -- automated input matrix generator |
I finally got around to wrapping up the SUS input matrix diagonalizer. The files I have added to ...scripts/SUS/peakFit are:
- kickAll: Restores all SUS angle biases using /cvs/cds/rtcds/caltech/c1/medm/c1ifo/cmd/C1IFO_OPTICrestore.cmd XXXX &, then runs 'freeswing all'. Finally, writes an elog entry with the time when the optics were kicked and saves the gps time to 'kickAll.time'.
- diagAllSUS.m: An M-file that calls all the other individual M-files needed for the matrix generation. What it does:
- Reads kick time from kickAll.time
- Runs getSensors.m to get time series from all optics' sensors
- Runs makeSUSSpectra.m to generate spectra from time series
- Runs findPeaks.m to fit spectra for peak frequencies
- Loops through all optics and runs, in sequence:
- inmat = findMatrix(XXXX) to generate the matrix for each optic
- writeSUSinmat(XXXX,inmat) to write that matrix to the frontend
- diagAllSUS: A wrapper for diagAllSUS.m. It also writes an elog entry and attaches the pre and post spectra demonstrating the diagonalization. The entry following this one is an example.
The following lines should eventually be added to the controls@nodus crontab:
0 8 * * 0 /cvs/cds/rtcds/caltech/c1/scripts/SUS/peakFit/kickAll
0 18 * * 0 /cvs/cds/rtcds/caltech/c1/scripts/SUS/peakFit/diagAllSUS
(i.e., do the kick at 8am on Sundays and run the diagonalization 10 hrs later at 6pm). They can be done on a different machine but then my elog commands will need to be modified.
Before we add them, we should check that they do, in fact, work. We can do this sometime while I'm at the 40m this week.
|
5764
|
Sun Oct 30 14:08:35 2011 |
rana | Update | Electronics | RFAM monitor in place. ( Uncalibrated ) EPICS troubles |
Quote: |
{Suresh, Jamie, Mirko]
We adapted the Stochmon box to include LP filters at 1.8Hz behind the RMS parts.
Then measured the RMS signals for different RF signal levels at 11.0.65, 29.5, 55.325MHz provided by a RF freq. generator.
As you can see in the data below the suppression of the BP filters of neighboring frequencies is only 35-35dB in power (see also manufacturer specs).
We therefor want to substract crosstalk, by calculating it out. We decided to use C-code in CDS. No computer crashing this time :)
|
This is neat idea, but it seems like it would be easier to just add another set of rf BP filters inside of the StochMon box. Luckily, Steve was thinking ahead and ordered extra filters. |
5763
|
Sat Oct 29 22:57:03 2011 |
Mirko | Update | LSC | AM modulation due to non-optimal SB frequency |
[Kiwamu, Mirko]
Non-optimal 11MHz SB frequency causes PM to be transformed into AM.
m_AM / m_PM = 4039 * 1kHz / df , with df beeing the amount the SB freq. is off.
Someone might want to double check ths. |
Attachment 1: IMC.pdf
|
|
5762
|
Sat Oct 29 05:50:44 2011 |
kiwamu | Update | LSC | MC suspensions misaligned to avid railing for PZTs |
I have shifted the alignment of the MC suspensions such that the PZT won't rail.
Since I didn't care of the spot positions on the MC mirrors, currently they are terribly off from the centers.
After the shift, I realigned the Stochmon PD again.
The attachments below shows the alignment of MC and PZTs before shifting the just for a record

Quote from #5754
|
Tomorrow night I will intentionally introduce offsets in the MC suspensions to avoid the railing.
The goal will be a scan of the incident beam while measuring the recycling gain.
|
|
5761
|
Sat Oct 29 02:35:39 2011 |
Suresh | Update | IOO | WFS_MASTER screen and lockin screens fixed |
I have fixed the WFS_MASTER screen and several of the subscreens such as the MCASS and MC_WFS_LKIN.
Since MC_WFS_LKIN uses six demodulators and single oscillator I could not use the automatically built Lockin screens.
I built one using the compact filter banks mentioned earlier
The phases in the WFSlockins have yet tp be set. |