5779
|
Tue Nov 1 19:26:38 2011 |
Zach | Update | SUS | "Dr. SUS" progress |
EDIT: Ran Jamie's NDS2 reset method and it's still not serving up MC data.
I am debugging the SUS input matrix diagonalization code (which I have affectionately termed "Dr. SUS") offline by running everything except the actual writing of the matrices (%writeSUSinmat()) in a sandbox directory. Some notes:
- nodus doesn't know NDS2, but this isn't a problem given Kiwamu's reply, since we don't want to push results to the elog. I will still have the script push "optics kicked---don't touch" alerts to the elog, but I realized this can be done easily from a remote computer via in-script SSH commands. My next choice was pianosa, but even though she knows NDS2, she spits out MEX errors when I try to get data. Third stop was allegra, and she plays nice

- NDS2 is unable to read the MC mirror sensor data. Data from all other optics are retrieved without a problem. I verified that raw data was being written by plotting playback data in dataviewer, and I tried various times and the problem persisted. I suspect the problem is on the NDS2 server side:
The most recent entry in .../users/jzweizig/nds2-mafalda/channel_history shows nothing for MC1 2 or 3
mafalda:channel_history>more C-R-999986048-178368.cls | grep SENSOR
C1:SUS-BS_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-BS_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-BS_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-BS_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-BS_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-ETMX_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-ETMX_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-ETMX_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-ETMX_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-ETMX_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-ETMY_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-ETMY_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-ETMY_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-ETMY_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-ETMY_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-ITMX_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-ITMX_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-ITMX_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-ITMX_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-ITMX_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-ITMY_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-ITMY_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-ITMY_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-ITMY_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-ITMY_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-PRM_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-PRM_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-PRM_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-PRM_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-PRM_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-SRM_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-SRM_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-SRM_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-SRM_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-SRM_SENSOR_UR raw 0 real_4 2048 C-R
|
5778
|
Tue Nov 1 18:45:48 2011 |
Jenne | Update | Computers | Allegra's screens |
I was trying to give Allegra a second head, and it didn't quite work. It's still in progress. Steve, you might not like how I've 'mounted' the second monitor, so we can talk about something that might work tomorrow. |
5777
|
Tue Nov 1 18:16:50 2011 |
Den | Update | Adaptive Filtering | Adaptive filter witness and EP SNR |
Quote: |
Coherence of seismometers to MCL:
STS1 is located at the vertex. x-axis along the x arm.
GUR1 is located at the IMC MC2 mirror. Same orientation.

=> 1. Only the x-direction has good coherence (to be expected)
2. Only good coherence at 1.5-4Hz (huh?)
So probably other noise sources are dominating. Let's look into noise projections. Remember IMC autoalignment is off.
A quick adaptive filter run with only the GUR1 and STS1 witnesses applied only to MCL didn't really do anything. Some more thought needs to be invested into the AA and shaping filters.
|
The possible explanation to this effect is the following:
Seismic noise mainly consists of the Love and Rayleigh surface waves. In the simulations we've taken 2 perpendicular Love waves and 2 perpendicular Rayleigh waves that interfere under the test mirrors. This interference produces both translational and tilt movements. Then we can see the coherence between translational motion and cavity length.

1. The coherence at big frequencies is small due to the passive isolation.
2. The coherence at 1 Hz is 0 due to the wire resonance.
3. The coherence between 1 and 10 Hz is reasonable. At the real 40m's measurements we can see only good coherence for gur1_x and sts1_x but this is the matter of adjusting seismic waves amplitude and direction. In the simulation we've assumed that all waves are of the same amplitude. The really interesting thing is that
4. The coherence below 0.8 Hz began to grow. We don't see this in real measurements.
But let's simulate the seismometer measurements. It measures not only translational motion but also tilt and with amplitude proportional to g / omega^2. On the Figure below the spectrum of translation motion, tilt and tilt as seen by seismometer is presented. We can see that at low frequencies tilt begins to dominate over the translational motion. We assumed the speed of waves in the region 30 - 60 m/sec.

Let's now plot the coherence between the cavity length and seismometer signal.

We can see that the coherence between seismic signal from measured by seismometer and cavity length is gone below 1 Hz where tilt becomes important.
Now let's try to filter out the seismic noise from the cavity length using both static Wiener filtering and adaptive Mfxlms algorithm. For both filters we've used AA filter before the filters and also AI filter after adaptive filter. The downsampling ratio was 4, the sample frequency 256. We can see that nothing is really subtracted due to the pollution of the seismometer signal due to tilt motion.

Assume we do the same computational experiment but with the seismometers that measure only ground translational motion and tilt do not affect on them. Then we have a reasonable subraction of seismic noise at low frequencies even with the filters of the length 100 as shown on the figure below.

Let's look through an order of magnitude analysis. Assume ground motion consists of only one wave with amplitude A and only vertical movement: z(t) = A*sin(2 pi 0.1 t). So the frequency of the wave is 0.1 Hz. If A = 10-6 m => the amplitude of the suspended mirror motion is also approximately 10-6 m, as we have no isolation at low frequencies. The tilt angle has the amplitude alpha = 2*pi*A/lambda, where lambda - wavelength of the ground wave, lambda = v/f = 40/0.1 = 400 m, v - speed of the wave, f - frequency. Then alpha = 10-8 rad. If the distance between ground and mirror suspension point is 1 m, then mirror motion amplitude due to tilt is B = 10-8 m << A.
It turns out that tilt does not effect much on the cavity length compared to the ground translational motion, but it affects a lot on the seismometer signals, that are used as witness signals in the filtering. For that reason we need tiltmeters to filter seismometer signals in order to obtain pure translational ground motion. |
5776
|
Tue Nov 1 16:02:15 2011 |
kiwamu | Update | SUS | Re: SUS input matrix diagonalizer REMOVED from crontab |
Quote: |
It turns out that nodus doesn't know how to NDS2, so I can't run diagAllSUS as a cron job on nodus. To further complicate things, no other machines can run the elog utility, so I am going to have to do something shifty...
|
Actually in the last 40m meeting we discussed the SUS diagnosis and decided not to post the results on the elog.
Alternatively we will have a summary web page which will contain all the information (sensitivity, UGF monitors, etc.,) and will be updated everyday like GEO.
This will be a place where we should post the SUS results every week.
So we don't need to worry about the cron-elog job, and for running the scripts you can simply use one of the lab machines as a cron host.
Once you get the scripts running on a machine as a cron job, it will be the point where we should quit developing the SUS diagonalizer and pass it to the web summary people. |
5775
|
Tue Nov 1 13:46:03 2011 |
Zach | Update | SUS | SUS input matrix diagonalizer REMOVED from crontab |
It turns out that nodus doesn't know how to NDS2, so I can't run diagAllSUS as a cron job on nodus. To further complicate things, no other machines can run the elog utility, so I am going to have to do something shifty... |
5774
|
Tue Nov 1 13:41:38 2011 |
Mirko | Update | LSC | AM modulation due to non-optimal SB frequency |
Quote: |
[Kiwamu, Mirko]
Non-optimal 11MHz SB frequency causes PM to be transformed into AM.
m_AM / m_PM = 4039 * 1kHz / df , with df beeing the amount the SB freq. is off.
Someone might want to double check ths.
|
Actually there was an error.
For 11MHz it is:
m_AM / m_PM = 2228 * 1kHz / df
For 55MHz:
m_AM / m_PM = 99.80 * 1kHz / df
see PDF |
Attachment 1: IMC.pdf
|
|
5773
|
Mon Oct 31 21:46:32 2011 |
kiwamu | Update | LSC | Dependence of Recycling gain on incident beam pointing |
I horizontally swept the translation of the incident beam in order to investigate a possible clipping in Power-recycled Michelson (PRMI).
The recycling gain of PRMI depended on the beam pointing but it did't improve the recycling gain.
I guess the amount of the entire shift I introduced was about +/- the beam diameter = +/- 5 mm or so.
Within the range of about +/- 5mm in the horizontal beam translation I didn't find any obvious sign of a clipping.
(Measurement)
This is the procedure which I did:
(1) Some amount of offsets were introduced on MC2 in both PIT and YAW such that the PZT1 won't rail ( #5762).
=> Every time when I introduced the offset I realigned the zig-zag mirrors on the PSL table to maintain the high transmissivity of MC.
(2) Fine tuning of the MC offsets so that the PZT1_X EPICS value becomes almost zero when the beam is aligned down to the Y arm.
=> 0.523 in C1:ASC_PZT1_X became a point where the coupling of the beam into the Y arm was maximized.
=> Last time the direction which we investigated was the positive side from this zero point ( #5709) in PZT1_X.
(3) Aligned MICH by steering BS.
(4) Locked PRMI with carrier resonating and aligned PRM to maximized the power recycling gain which was obtained from POYDC.
(5) Translated the beam pointing
=> First I shifted PZT1_X by a wanted amount.
=> Then I locked the Y arm and realigned PZT2_X by maximizing the Y arm transmission.
This procedure should give us a pure translation on the incident beam.
(6) Repeated the same procedure (3) through (5) in each PZT1 position.
(Results)
Here shows the measured recycling gain and the power reflectivity of PRMI as a function of the beam pointing.

Upper plot : measured recycling gains (Red) observed maximum values (Black) measured values on average.
Lower plot : measured power reflectivity of PRMI (Blue) observed minimum values (Black) measured values on average.
As shown in the plots the recycling gain could go up to 8 at some points.
As the PZT went away from 0 it decreased and eventually became about 3 in each side.
The reflectivity showed the minimum value of 0.4 when the PZT1 was at -1 in EPICS value.
One hypothesis to explain this plot can be that : we are just seeing the effect of the incident beam misalignment.
|
5772
|
Mon Oct 31 19:39:00 2011 |
Jenne | Update | Adaptive Filtering | Screens, code, computers |
[Mirko, Jenne]
I finished (mostly? maybe?) the OAF screens. They're pretty awesome.
While we were playing with the OAF, trying to do some oafing, the output of the code decided to just be zeros. We did a test, and in the c-code set the output to be a constant value, and that worked. But when we put it back to normal (being adaptive) and recompiled, it still only outputs zeros. The code is receiving both witness and error signals, so we don't know what's going on.
In the course of trying to make things work again, we did a complete reboot of c1lsc and c1sus. Did a burt restore. Everything (except our weird code problem) should be fine again. Optics are damping happily. |
5771
|
Mon Oct 31 15:58:25 2011 |
steve | Update | SUS | thinking of black glass baffles for 40m |
Shade 12 black glass-green lines: 1/8" thick, 6" wide x 7 " high mounted on angle bracket below. Aperture 1" diameter. Let me know what do you think.
|
Attachment 1: 03260901.PDF
|
|
Attachment 2: 03260902.PDF
|
|
5770
|
Mon Oct 31 14:06:16 2011 |
Zach | Update | SUS | SUS input matrix diagonalizer added to crontab |
I actually tried to do this last night, but I was getting a terminal error from nodus. Jamie told me to just manually redefine the TERM variable and it would work. So, I have added kickAll and diagAllSUS to controls@nodus's crontab:
nodus:~>crontab -l
0 5 * * * /opt/rtcds/caltech/c1/scripts/backup/rsync.backup
0 7 * * * /opt/rtcds/caltech/c1/scripts/backup/check_backup.sh
0 17 * * 0 /cvs/cds/caltech/users/jenne/LIGOX/LIGOX_Pizza_Reminders.sh
0 8 * * 0 /cvs/cds/rtcds/caltech/c1/scripts/SUS/peakFit/kickAll
0 18 * * 0 /cvs/cds/rtcds/caltech/c1/scripts/SUS/peakFit/diagAllSUS
Again, their functionality should be checked before this is allowed to run on Sunday!
|
5769
|
Mon Oct 31 14:01:56 2011 |
Katrin | Update | Green Locking | YARM locks for 2h |
Today, I could lock the YARM laser for 2h to the YARM cavity. After to hours the output of the servo is saturated. I need to work on thermal feedback to the laser.
It is a nice TEM00 mode and the green light enters PSL table.

Measured with pin-ball machine spectrum analyzer (I forgot the real name, but it is the one that makes sounds like a pin-ball machine), source power10mVp, Lb1005 gain 2.05.
Setup

Input offset of LB1005 is zero
Locking history
On Thursday, Oct 27, lock for 3 min
On Friday, Oct 28, lock up to 18 min, improvements done by
- finding the right adjustment of PI Corner frequency and gain
- better alignment of the light to the cavity
- I used a high-pass filter between LO and LB1005, but no improvement of lock. In contrast, it got worse.
On Monday,Oct 31, careful adjustment of summing box (rear of of LB1005), lock up to 2h, limited by saturated feedback signal --> work on slow control
Some more plots



|
Attachment 1: 20111031_OLTF.png
|
|
Attachment 2: YARM_setup.png
|
|
5768
|
Mon Oct 31 09:42:12 2011 |
steve | Update | IOO | PMC locked |
The PMC HV drops off more offen lately. |
Attachment 1: pmcHV.png
|
|
5767
|
Mon Oct 31 08:55:19 2011 |
steve | Update | VAC | pressure plot at day 53 |
Quote: |
I was lucky to notice that the nitrogen supply line to the vacuum valves was leaking. Closed ALL valves. Open supply line to atm. Fixed leak.
This was done fast so the pumps did not have to be shut down. Pressurized supply line and open valves to
"Vac Normal" condition in the right sequence.
|
|
Attachment 1: pd71-m-d53.png
|
|
5766
|
Sun Oct 30 23:03:37 2011 |
SUS_Diagonalizer | Update | SUS | SUS input matrix diagonalization complete (EXAMPLE) |
New SUS input matrix diagonalization complete. Matrices have been written to the frontend. Summaries for each optic can be viewed below.
(THIS IS AN EXAMPLE---no new matrices have been written.) |
Attachment 1: MC1.png
|
|
Attachment 2: MC2.png
|
|
Attachment 3: MC3.png
|
|
Attachment 4: ETMX.png
|
|
Attachment 5: ETMY.png
|
|
Attachment 6: ITMX.png
|
|
Attachment 7: ITMY.png
|
|
Attachment 8: PRM.png
|
|
Attachment 9: SRM.png
|
|
Attachment 10: BS.png
|
|
5765
|
Sun Oct 30 23:01:51 2011 |
Zach | Update | SUS | diagAllSUS -- automated input matrix generator |
I finally got around to wrapping up the SUS input matrix diagonalizer. The files I have added to ...scripts/SUS/peakFit are:
- kickAll: Restores all SUS angle biases using /cvs/cds/rtcds/caltech/c1/medm/c1ifo/cmd/C1IFO_OPTICrestore.cmd XXXX &, then runs 'freeswing all'. Finally, writes an elog entry with the time when the optics were kicked and saves the gps time to 'kickAll.time'.
- diagAllSUS.m: An M-file that calls all the other individual M-files needed for the matrix generation. What it does:
- Reads kick time from kickAll.time
- Runs getSensors.m to get time series from all optics' sensors
- Runs makeSUSSpectra.m to generate spectra from time series
- Runs findPeaks.m to fit spectra for peak frequencies
- Loops through all optics and runs, in sequence:
- inmat = findMatrix(XXXX) to generate the matrix for each optic
- writeSUSinmat(XXXX,inmat) to write that matrix to the frontend
- diagAllSUS: A wrapper for diagAllSUS.m. It also writes an elog entry and attaches the pre and post spectra demonstrating the diagonalization. The entry following this one is an example.
The following lines should eventually be added to the controls@nodus crontab:
0 8 * * 0 /cvs/cds/rtcds/caltech/c1/scripts/SUS/peakFit/kickAll
0 18 * * 0 /cvs/cds/rtcds/caltech/c1/scripts/SUS/peakFit/diagAllSUS
(i.e., do the kick at 8am on Sundays and run the diagonalization 10 hrs later at 6pm). They can be done on a different machine but then my elog commands will need to be modified.
Before we add them, we should check that they do, in fact, work. We can do this sometime while I'm at the 40m this week.
|
5764
|
Sun Oct 30 14:08:35 2011 |
rana | Update | Electronics | RFAM monitor in place. ( Uncalibrated ) EPICS troubles |
Quote: |
{Suresh, Jamie, Mirko]
We adapted the Stochmon box to include LP filters at 1.8Hz behind the RMS parts.
Then measured the RMS signals for different RF signal levels at 11.0.65, 29.5, 55.325MHz provided by a RF freq. generator.
As you can see in the data below the suppression of the BP filters of neighboring frequencies is only 35-35dB in power (see also manufacturer specs).
We therefor want to substract crosstalk, by calculating it out. We decided to use C-code in CDS. No computer crashing this time :)
|
This is neat idea, but it seems like it would be easier to just add another set of rf BP filters inside of the StochMon box. Luckily, Steve was thinking ahead and ordered extra filters. |
5763
|
Sat Oct 29 22:57:03 2011 |
Mirko | Update | LSC | AM modulation due to non-optimal SB frequency |
[Kiwamu, Mirko]
Non-optimal 11MHz SB frequency causes PM to be transformed into AM.
m_AM / m_PM = 4039 * 1kHz / df , with df beeing the amount the SB freq. is off.
Someone might want to double check ths. |
Attachment 1: IMC.pdf
|
|
5762
|
Sat Oct 29 05:50:44 2011 |
kiwamu | Update | LSC | MC suspensions misaligned to avid railing for PZTs |
I have shifted the alignment of the MC suspensions such that the PZT won't rail.
Since I didn't care of the spot positions on the MC mirrors, currently they are terribly off from the centers.
After the shift, I realigned the Stochmon PD again.
The attachments below shows the alignment of MC and PZTs before shifting the just for a record

Quote from #5754
|
Tomorrow night I will intentionally introduce offsets in the MC suspensions to avoid the railing.
The goal will be a scan of the incident beam while measuring the recycling gain.
|
|
5761
|
Sat Oct 29 02:35:39 2011 |
Suresh | Update | IOO | WFS_MASTER screen and lockin screens fixed |
I have fixed the WFS_MASTER screen and several of the subscreens such as the MCASS and MC_WFS_LKIN.
Since MC_WFS_LKIN uses six demodulators and single oscillator I could not use the automatically built Lockin screens.
I built one using the compact filter banks mentioned earlier
The phases in the WFSlockins have yet tp be set. |
5760
|
Fri Oct 28 20:39:19 2011 |
MIrko | Update | LSC | RFAM monitor in place. ( Uncalibrated ) EPICS troubles |
{Suresh, Jamie, Mirko]
We adapted the Stochmon box to include LP filters at 1.8Hz behind the RMS parts.
Then measured the RMS signals for different RF signal levels at 11.0.65, 29.5, 55.325MHz provided by a RF freq. generator.
As you can see in the data below the suppression of the BP filters of neighboring frequencies is only 35-35dB in power (see also manufacturer specs).
We therefor want to substract crosstalk, by calculating it out. We decided to use C-code in CDS. No computer crashing this time :)
We however ran into the problem that the RMS signal channels are acquired by the slow (EPICS) maschine c1iool0. Channels are (C1:IOO-RFAMPD_33MHZ , -"-133MHZ, -"-166MHZ) and we could not access those in the CDS c1ioo model. Using the EpicsIn block we got an CA.Exception stating that the variable was hosted on multiple servers. We then tried to use the EzcaRead to access the variables. Got an compile error, about the compiler not beeing able to connect all parts. It seems that the EzcaRead left behind a "ghost" part in the model (something with M1:SYS-FOO_BAR which is the default naming of the EzcaRead block) even after we deleted that block. We toyed around with the /opt/rtcds/caltech/c1/chans/daq/C1EDU_IOO.ini and /cvs/cds/caltech/target/c1iool0/ioo.db files. We tried to uncomment the "old" (33,133,166) channels there to get rid of the conflict, but that didn't work.
We want to write the outputs to C1:IOO-RFAMPD_11MHZ , -"-29MHZ, -"-55MHZ EPICS channels.
We had to get the model back from the svn to get it running again. |
Attachment 1: MC_DC11MHz.m
|
Pwr=[-60,-55,-50,-45,-40,-35,-30,-25,-20,-10,-5,0,5,10]';
Voltage11=[2.12,2.10,2.03,1.93,1.83,1.71,1.59,1.47,1.35,1.10,0.97,0.85,0.71,0.61]';
Voltage11=spline(Pwr,Voltage11,linspace(-60,10,15));
PwrSmooth=linspace(-60,10,15);
Voltage29=[2.14,2.14,2.14,2.14,2.14,2.14,2.13,2.12,2.09,1.94,1.84,1.73,1.61,1.49];
Voltage29=spline(Pwr,Voltage29,linspace(-60,10,15));
Voltage55=[2.16,2.16,2.16,2.16,2.16,2.16,2.16,2.15,2.14,2.13,2.10,2.04,1.94,1.83];
... 5 more lines ...
|
Attachment 2: MC_DC29MHz.m
|
Pwr=[-60,-55,-50,-45,-40,-35,-30,-25,-20,-15,-10,-5,0,5,10]';
Voltage11=[2.16,2.16,2.16,2.16,2.15,2.16,2.15,2.13,2.10,2.03,1.93,1.81,1.70,1.58,1.46]';
Voltage29=[2.12,2.10,2.03,1.93,1.83,1.70,1.59,1.47,1.34,1.22,1.09,0.97,0.84,0.71,0.61]';
Voltage55=[2.16,2.15,2.16,2.16,2.15,2.15,2.14,2.10,2.0,1.97,1.97,1.77,1.65,1.50,1.37]';
%% Example 55MHz inj.
Voltage11=[2.00];
... 21 more lines ...
|
Attachment 3: MC_DC55MHz.m
|
Pwr=[-60,-55,-50,-45,-40,-35,-30,-25,-20,-15,-10,-5,0,5,10]';
Voltage11=[2.16,2.16,2.16,2.16,2.16,2.15,2.15,2.15,2.15,2.15,2.12,2.09,2.00,1.89,1.78]';
Voltage29=[2.14,2.14,2.14,2.13,2.14,2.13,2.11,2.06,1.98,1.88,1.76,1.64,1.52,1.40,1.27]';
Voltage55=[2.14,2.11,2.05,1.96,1.85,1.73,1.61,1.48,1.36,1.23,1.10,0.98,0.84,0.71,0.61]';
plot(Pwr,Voltage55)
%%
... 17 more lines ...
|
Attachment 4: RFAMPD.c
|
double x;
double y;
double z;
double temp1;
double temp2;
double Corrx;
double Corry;
double Corrz;
... 49 more lines ...
|
5759
|
Fri Oct 28 18:33:59 2011 |
steve | Update | VAC | leaking nitrogen line fixed |
I was lucky to notice that the nitrogen supply line to the vacuum valves was leaking. Closed ALL valves. Open supply line to atm. Fixed leak.
This was done fast so the pumps did not have to be shut down. Pressurized supply line and open valves to
"Vac Normal" condition in the right sequence. |
Attachment 1: allvalvesclosed.png
|
|
5758
|
Fri Oct 28 15:45:52 2011 |
Mirko | Update | Computers | Nifty screen generator |
Quote: |
Suresh showed me a cool script that Mirko made, but didn't elog about.
You tell the script what filter banks you want, and it creates a screen for each with a bunch of different filter module display formats. Then you can copy the format you like into the actual screen you're modifying.
Currently PEM, LSC and IOO (and maybe others?) have "fmX" folders inside their medm/c1.../master folders. For each subsystem, we need to copy this folder, and modify the generic .adl file so that it puts in the correct subsystem letters. Once this is done, you can just run the generateFMscreens.py after putting in your filter bank names.
|
Wasn"t me. |
5757
|
Fri Oct 28 15:33:06 2011 |
Jenne | Update | Computers | Nifty screen generator |
Suresh showed me a cool script that Mirko made, but didn't elog about.
You tell the script what filter banks you want, and it creates a screen for each with a bunch of different filter module display formats. Then you can copy the format you like into the actual screen you're modifying.
Currently PEM, LSC and IOO (and maybe others?) have "fmX" folders inside their medm/c1.../master folders. For each subsystem, we need to copy this folder, and modify the generic .adl file so that it puts in the correct subsystem letters. Once this is done, you can just run the generateFMscreens.py after putting in your filter bank names. |
5756
|
Fri Oct 28 14:56:02 2011 |
Jenne | Update | CDS | CSS/BOY installed on pianosa |
Quote: |
I've installed Control System Studio (CSS) on pianosa, from the version 3.0.2 Red Hat binary zip. It should be available as "css" from the command line.
CSS is a new MEDM replacement. It's output is .opi files, instead of .adl files. It's supposed to include some sort of converter, but I didn't play with it enough to figure it out.
Please play around with it and let me know if there are any issues.
links:
|
So far I've only given it about half an hour of my time, but it is *really* frustrating so far. There don't seem to be any instructions on how to tell it what our channels are / how to link CSS to our EPICS databases. Or, the instructions that are there say "do it!", but they neglect to mention how... Also, there exists (maybe?) an ADL->BOY converter, but I can't find any buttons to click, or how to import an .adl, or what I'm supposed to do. Also, it's not clear how to get to the editor to start making screens from scratch.
It looks like it has lots of nifty indicators and buttons, but I would have felt better if I had been able to do anything.
Another thing that is going to be a problem: the Shell Command button that we use all over the place in our MEDM screens is not supported by this program. It's listed in the "limitations" of the ADL2BOY converter. This may kill the CSS program immediately. Jamie: did Rolf/anyone mention a game plan for this? It's super nice to be able to run scripts from the screens.
Moral of the story: I'm annoyed, and going to continue making my OAF screens in MEDM for now. |
5755
|
Fri Oct 28 12:47:38 2011 |
jamie | Update | CDS | CSS/BOY installed on pianosa |
I've installed Control System Studio (CSS) on pianosa, from the version 3.0.2 Red Hat binary zip. It should be available as "css" from the command line.
CSS is a new MEDM replacement. It's output is .opi files, instead of .adl files. It's supposed to include some sort of converter, but I didn't play with it enough to figure it out.
Please play around with it and let me know if there are any issues.
links:
|
5754
|
Fri Oct 28 05:17:13 2011 |
kiwamu | Update | LSC | locking activity : PZT1 is still railing |
Status update on the LSC activity:
To see how good/bad the beam pointing is, I locked the Y arm with POY11.
Then I ran the ASS servo to automatically correct the alignment of the ITMY and ETMY suspensions and also the beam pointing.
The result is that the PZT1_X is still railing to the negative side.
Due to it the transmitted light from the Y arm is about 0.6 or so which is supposed to be 1 if the beam pointing is perfect.
The EPICS value of PZT1_X is at the minimum of -10 and the ASS servo tried to push it more negative side.
Tomorrow night I will intentionally introduce offsets in the MC suspensions to avoid the railing.
The goal will be a scan of the incident beam while measuring the recycling gain. |
5753
|
Fri Oct 28 04:57:00 2011 |
kiwamu | Update | LSC | POX11 demod board broken |
The POX11 demodulation board is broken. It needs to be fixed in the daytime tomorrow.
It only outputs the Q signal and nothing is coming out from the I output.
(Some stuff checked)
[OK] ADCs
[OK] Whitening filters looked fine. Their gains were controllable from EPICS.
[OK] Connection between the POX11 RFPD and demodulator box
[OK] The Q signal showed the PDH signal of the X arm with an amplitude of about 200 counts, which almost is the same as that of POY11.
[NOT GOOD] The I signal from the demod board
[OK] Outputs cables, which send the I and Q signals from the demod board to WFs are fine.
(Test on the POX11 demod board)
As usual, a test signal whose frequency is shifted by a little bit from that of LO was injected to the RF input of the board to see if the circuit is working.
The I signal didn't show up and there were no signals even in the monitor LEMO output.
Something is wrong in the I signal demodulation path on the circuit board.
Here is an actual time series of the I and Q signals in dataviewer. The I signal outputs just junk while the Q showed a nice sine curve.
 |
5752
|
Fri Oct 28 03:42:50 2011 |
kiwamu | Update | LSC | ITMX table needs to be refined |
(POX)
The POX beam had been 80% clipped at a black glass beam dump of the POX11 RFPD.
I steered the first mirror in the POX path to fix the clipping. Then the beam was realigned onto the RFPD.
However the beam is still very close to the black glass, because the incident angle to the second mirror is not 45 deg .
We need to refine the arrangement of the POX11 optics a bit more so that the beam will never be clipped at the black glass.
(POP)
The POP optics also need to be rearranged to accommodate one more RFPD.
Additionally Rana, Suresh and I discussed the possible solutions of POP22/110 and decided to install a usual PD (PDA10A or similar) instead of a custom-made.
So a plan for the POP detectors will be something like this:
+ design an optical layout.
+ buy a 2 inch lens whose focul length is long enough ( #5743 )
+ rearrange the optics and install POP22/110
+ lay down a long SMA cable which sends the RF signal from POP22/110 to the LSC rack.
+ install a power splitter just before the demod board so that the signal is split into the 22MHz demoad board and 110MHz demod board.
=> make sure we have a right splitter for it.
+ install a band pass filter after the power splitter in each path.
=> A 22MHz band pass filter is already in hand. Do we have 110MHz band pass filter somewhere in the lab ?
The picture here shows the latest configuration on the ITMX table.

Quote from #5743 |
RF photo diodes POP55 and POX11 are installed. The beams are aligned to the photo diodes.
|
|
5751
|
Fri Oct 28 03:12:37 2011 |
Suresh | Update | IOO | MC2 realigned to align MC to PSL |
Around 6PM on the 27th, I found that the C1:IOO-MC_RFPD_DCMON had risen to about 2.5V. I checked the trend of MC2 sensors and found that between 2PM and 6PM, MC2 had drifted in a strange way. And also that the alignment had grown worse over several days. I also noticed that the spot on the MC2F camera had shifted to the left.
I attempted to correct the alignment (decrease the C1:IOO-MC_RFPD_DCMON to ~0.5V ) by just moving the MC2 and succeeded!! So it is quite likely that most of the slow MC drift is arising due to MC2 table drift.

I decided to try and close the MC2_TRANS QPD to MC2 loops separately to see if MC alignment becomes stable But several screens needed to be fixed before we could try anything. So I fixed C1IOO_WFS_MASTER, C1IOO_WFS_INMATRIX and ...OUTMATRIX screens. Deleted the older ones to avoid confusion.
In this process I noticed that the directory of $screens$/c1mcs/master contains copies of older C1SUS_MC1 , 2. and 3 screens which look very similar to the new autogenerated screens. Some of the links in the WFS screens were pointing to the old screens. I have redirected the links and I will delete these in a couple of days, if no one objects.
|
5750
|
Fri Oct 28 02:41:18 2011 |
Suresh | Metaphysics | elog | elog unresponsive: restarted |
Elog did not respond despite running the /cvs/cds/caltech/elog/start-elog.csh script two times.
It worked the after the third restart.
|
5749
|
Fri Oct 28 01:13:17 2011 |
kiwamu | Update | SUS | ITMX oplev : iris fully opened |
I found that the sum of the ITMX oplev signals had gone down to zero yesterday.
I checked the ITMX table and found two iris on the He-Ne laser path were blocking the beam on their apertures.
I guess this is because we were working around there for installation of POP/POX and may have touched some of the oplev optics.
Then I fully opened the apertures of those two iris and the sum went back to nominal of 600 counts. |
5748
|
Fri Oct 28 00:53:39 2011 |
rana | Update | Electronics | POP 22/110 Design |
The attached PDF shows a possible gain / input noise config for the POP 22/110 that we would use to detect the RF power in the DRMI. Design is in the SVN.
If Kiwamu/Jenne say that this has good enough sensing noise for the lock triggering than we will build it. This is using a 2mm diode.
If we can get away with 1 mm, we might as well use a PDA10CF for now. |
Attachment 1: poy22110.pdf
|
|
5747
|
Thu Oct 27 18:00:38 2011 |
kiwamu | Summary | LSC | Offsets in LSC signals due to the RFAMs : Optickle simulation |
The amount of offsets in the LSC signals due to the RFAMs have been estimated by an Optickle simulation.
The next step is to think about what kind of effects we get from the RFAMs and estimate how much they will degrade the performance.
(Motivation)
We have been having relatively big RFAM sidebands ( #5616), which generally introduce unwanted offsets in any of the LSC demodulated signals.
The motivation was that we wanted to estimate how much offsets we've been having due to the RFAMs.
The extreme goal is to answer the question : 'How big RFAMs do we allow for operation of the interferometer?'.
Depending on the answer we may need to actively control the RFAMs as already planed ( #5686).
Since the response of the interferometer is too complicated for analytic works, so a numerical simulation is used.
(Results : Offsets in LSC error signals)



Figure: Offsets in unit of meter in all the LSC demodulated signals. Y-axis is the amount of the offsets and the X-axis represents each signal port.
In each signal port, the signals are classified by color.
(1) Offsets in the PRCL signal. (2) Offsets in the MICH signal. (3) Offsets in the SRCL signal.
Roughly the signals showed offsets at a 0.1 nm level.
The numerical error was found to be about 10-10 nm by running the same simulation without the AM sidebands.
Here is a summary of the amount of the offsets:
|
offsets [nm] (1f signal port) |
offsets [nm] (3f signal port) |
biggest offsets [nm] (signal port) |
PRCL |
0.3 (REFL11) |
0.2 (REFL33) |
1 (REFL55) |
MICH |
0.00009 (AS55) |
0.8 (REFL33) |
7 (POP11) |
SRCL |
0.1 (REFL55) |
0.1 (REFL165) |
40 (POX11) |
In the SRCL simulation REFL11I, REFL11Q, POP11I, POP11Q and POX11I didn't show any zero crossing points within 100 nm range around the resonance.
It is because that the SRCL doesn't do anything for the 11MHz sidebands. So it is the right behavior.
However POX11 was somewhat sensitive to the SRCL motion and showed a funny signal with a big offset.
(Simulation setup)
I applied the current PM/AM ratio according to the measurement ( #5616, #5519)
The modulation indices used in the simulation are :
+ PM index in 11MHz = 0.17
+ PM index in 55MHz = 0.14
+ AM index in 11MHz = 0.17 / 200 = 8.5x10-4
+ AM index in 55MHz = 0.14 / 200 = 7.0x10-4
Note that the phases of the AM and PM sidebands are the same.
For clarity, I also note the definition of PM/AM ratio as well as how the first order upper sideband looks like.


The optical parameters are all at ideal length although we may want to check the results with more realistic parameters:
+ No arm cavities
+ PRCL length = 6.75380
+ SRCL length = 5.39915
+ Schnupp asymmetry = 3.42 cm
+ loss in each optic = 50 ppm
+ PRCL = resonant for 11 and 55MHz
+ MICH = dark fringe
+ SRCL = resonant for 55 MHz
The matlab script will be uploaded to the cvs server.
Quote from #5686 |
8. In parallel to those actions, figure out how much offsets each LSC error signal will have due to the current amount of the RFAMs.
=> Optickle simulations.
|
|
5746
|
Thu Oct 27 16:09:37 2011 |
kiwamu | Update | LSC | RF distribution box : two more 55MHz available |
The diagram of the RF distribution box has been updated according to the modification ( #5744).
Both pdf and graffle files are available on the 40m svn : https://nodus.ligo.caltech.edu:30889/svn/trunk/suresh/40m_RF_upgrade/
Here shows the latest version of the diagram.

Quote from #5744 |
I will update the diagram of the RF distribution box (#4342) tomorrow.
|
|
5745
|
Thu Oct 27 03:32:45 2011 |
Koji | Summary | IOO | RFAM monitor progress |
[Suresh, Mirko, Koji]
A cable from the stochmon box to the cross connect for the EPICS ADCs is installed.
The power supply and the signal outputs are concentrated in a single DSub 9pin connector
that is newly attached on the box.
The connection from the stochmon side of the cable and the EPICS value was confirmed.
The calibration of them looks fine.
To do:
- Once the stochmon box is completed we can immediately test it.
- The EPICS channel names are still as they were. We need to update the database file of c1iool0, the chans file for the slow channel.
The pinout is as following
-------------
| 1 2 3 4 5 | Female / Inside View
\ 6 7 8 9 /
\---------/
1 - 11MHz Signal
2 - 30MHz Signal
3 - 55MHz Signal
4 - NC
5 - +5V supply
6 - 11MHz Return
7 - 30MHz Return
8 - 55MHz Return
9 - Supply ground |
5744
|
Wed Oct 26 23:03:03 2011 |
kiwamu | Update | LSC | RF distribution box : two more 55MHz available |
The RF distribution box has been modified so that it generates two more 55 MHz LO signals.
After the modification I put the box back in place.
Then I checked the MICH and YARM locking quickly as a working test of the distribution box and it is working fine so far.
I will update the diagram of the RF distribution box (#4342) tomorrow.
(Motivation)
Since we newly installed POP55 (#5743) an LO signal was needed for the demodulation.
However the RF distribution box didn't have any extra LO outputs.
Therefore we had to make a modification on the RF distribution box so that we can have a 55MHz LO signal for POP55.
Eventually I made two more 55MHz outputs including one spare.
(Modification)
The box actually had two extra output SMAs which had been just feed-thru connectors on the front panel without any signals going through.
In the box the modules consist of two categories; the 11MHz system and 55MHz system. I modified only a part of the 55MHz system.
The modification was done in this way:
* split two branches of 55MHz into four branches by installing two new power splitters (ZMSC-2-1).
* made and installed some SMA cables whose length were adjusted to be nicely fit in the box.
* readjustment of the RF levels to 0-2 dBm at the outputs by replacing some attenuators.
* checked the signals if all of them were happily coming out or not.
Also I found that the POX11 and POY11 demod boards were connected to the whitening filters in a wrong way.
The I and Q signals were in a wrong order. So I corrected them so that the upper inputs in the whitening filter is always the I signal.
(RF levels on 55MHz LO outputs)
Since the demod board requires a certain level of the RF signal as as LO, the LO signals have to be 0-2 dBm.
Here are the RF level in each 55MHz output after the adjustment of the level.
AS55 = 0.76 dBm
REFL55 = 0.76 dBm
POP55 = 0.79 dBm
spare = 0.83 dBm
Those numbers were measured by an oscilloscope and the oscilloscope was configured to measure the rms with the input impedance matched to 50Ohm.
In the measurement I used the actual input seed 55MHz signal from the RF generation box to drive the distribution box. |
5743
|
Wed Oct 26 20:30:47 2011 |
Katrin | Update | LSC | POX11 and POP55 installed |
[Katrin,Jenne]
RF photo diodes POP55 and POX11 are installed. The beams are aligned to the photo diodes.
PD |
DC out dark |
DC out bright |
light power |
calculated DC output |
|
POX11 |
0.1mV |
1.3mV |
0.09mW |
3mV |
POP55 |
35mV |
55mV |
3 to 4 µW |
25mV |
I used 0.7 A/W for the response and 50V/A for POP55 according to elog page #4576.
To install the third RF photo diode we need to order a plano-convex lens with a focal length of 750 or
maybe even better 1000 |
5742
|
Wed Oct 26 11:35:08 2011 |
Katrin | Update | Green Locking | YARM PDH box |

From time to time the 20 dB jump in the transfer function still occurs. The new AD8336 op amp did not change that issue. I am sure that the op amp was broken,
because the amplitude of the sine did not change when I turned the gain knob.
The above two curves were measured with different input amplitude of the sine from the spectrum analyzer. Nothing changed in between except that there was no
jump when Kiwamu was around. Very strange. Testing the electronic board led to no clue what is happening.
For now, I will just use the PDH box as it is, but one should keep this odd behaviour in mind. |
5741
|
Wed Oct 26 10:07:16 2011 |
steve | Update | General | no electricity ....... will be recheduled |
Quote: |
Subject: Electricity Interruption- 11/19/11
From: "PP Service Center" <PPService@caltech.edu>
To: "DeLaRosa, Dario" <Dario.DeLaRosa@caltech.edu>,
...snip... "Sullivan, Joan O." <sully@caltech.edu> |
CALIFORNIA INSTITUTE OF TECHNOLOGY
FACILITIES MANAGEMENT
UTILITY & SERVICE INTERRUPTION
**PLEASE POST**
Building: Central Engineering Services (C.E.S.)
LIGO Gravitational Physics building adjacent to C.E.S.
Safety Storage adjacent to CES
Steele House
Keck Lab
Date: November 19, 2011
Time: 8:00 a.m. To 9:00 a.m.
Interruption: Electricity
Contact: Mike Anchondo ext. 4999 Tom Brennan 4984
*This interruption is required for maintenance of high voltage switchgear in Campus Sub Station.
|
CANCELLED, WILL BE RESCHEDULED* |
5740
|
Tue Oct 25 21:49:13 2011 |
Den | Update | Adaptive Filtering | Adaptive filter witness and EP SNR |
Quote |
Coherence of seismometers to MCL:
STS1 is located at the vertex. x-axis along the x arm.
GUR1 is located at the IMC MC2 mirror. Same orientation.

=> 1. Only the x-direction has good coherence (to be expected)
2. Only good coherence at 1.5-4Hz (huh?)
So probably other noise sources are dominating. Let's look into noise projections. Remember IMC autoalignment is off.
A quick adaptive filter run with only the GUR1 and STS1 witnesses applied only to MCL didn't really do anything. Some more thought needs to be invested into the AA and shaping filters.
|
Indeed, only GUR1_X is reasonable. Static Wiener filtering (length = 2500) of MCL with witness channels GUR_1_X, GUR_1_Y, GUR_1_Z proves your measurements.
We need to callibrate seimometers. I think that now we see velocity, not displacement. It might be useful to amplify the seimometer singal before ADC to make sure that our signal is not ADC noise. |
Attachment 1: gur1_x.jpg
|
|
Attachment 2: gur1_y.jpg
|
|
Attachment 3: gur1_z.jpg
|
|
5739
|
Tue Oct 25 21:23:17 2011 |
Dmass | Bureaucracy | elog | Elog Restarted |
Elog went nonreponsive. SSH'ed into nodus to run restart script. Elog came back ~15 minutes later. |
5738
|
Tue Oct 25 20:04:40 2011 |
Mirko | Update | Adaptive Filtering | Adaptive filter witness and EP SNR |
We currently have the code running for all DOFs using all witness channels. By default nothing is applied. C-Code parameters can be changed via the respective EPICS variables. Sanity checks in the C-Code make sure the code doesn't crash when nothing / zeros are fed to the code. Let's look into applying FF to one DOF only as a starting point. We start with MCL.
Remember there are two possible signals to look into MC-F and MC-Servo. See page 5695 http://nodus.ligo.caltech.edu:8080/40m/5695
Dark noise: MC-F over MC-Servo which is unconnected in this measurement:

=> At least 20dB SNR. ADC noise should not be an issue. Of course more is always better.
Coherence of seismometers to MCL:
STS1 is located at the vertex. x-axis along the x arm.
GUR1 is located at the IMC MC2 mirror. Same orientation.

=> 1. Only the x-direction has good coherence (to be expected)
2. Only good coherence at 1.5-4Hz (huh?)
So probably other noise sources are dominating. Let's look into noise projections. Remember IMC autoalignment is off.
A quick adaptive filter run with only the GUR1 and STS1 witnesses applied only to MCL didn't really do anything. Some more thought needs to be invested into the AA and shaping filters. |
5737
|
Tue Oct 25 18:50:22 2011 |
Suresh | Update | IOO | C1IOO model modified to include new WFS lockin structure |
Some small fixes to the c1ioo model.
1) I edited the WFS lockin modules to make use of new library part called demod.
2) c1ioo model has been compiled and restarted.
3) fb was restarted at Tue Oct 25 18:43:55 PDT 2011
Quote: |
I forgot to mention another change I made to the C1IOO model.
The location of the WFS global switch has been shifted. It now cuts off signals just before the WFS servo filters.
I have also added some test points just before the switch so that we can monitor the WFS sensor signals even if the switch is off.
Quote:
|
A while back we faced the problem that when we use several lockins to excite the MC degrees of freedom, their relative phase was not known. The solution suggested was to use one oscillator and several demodulators.
I have now modified the C1IOO.mdl so that this can be implemented. Previously we were using the MC_ASS lockins for WFS work. I have not separated the WFS and MC_ASS structures.
Other jobs to be done in this context are:
1) The medm screens associated with WFS lockins need to be updated with new channel names.
2) The scripts associated with both MC_ASS decentering and WFS ouput matrix determination have to be updated with the new channel names.
3) I also deleted all mdem screens in the $screens$/c1ioo/ directory after copying them to $screens$/c1ioo/bak/. After installing the new c1ioo model $screens$/c1ioo model now contains just the automatically created screens. All other user made screens should to into $screens$/c1ioo/master/ directory
This is a pic of the new c1ioo model:

|
|
|
5736
|
Tue Oct 25 18:09:44 2011 |
jamie | Update | CDS | New DEMOD part |
I forgot to elog (bad Jamie) that I broke out the demodulator from the LOCKIN module to make a new DEMOD part:

The LOCKIN part now references this part, and the demodulator can now be used independently. The 'LO SIN in' and 'LO COS in' should receive their input from the SIN and COS outputs of the OSCILLATOR part. |
5735
|
Tue Oct 25 16:24:58 2011 |
Suresh | Update | IOO | C1IOO model modified to include new WFS lockin structure |
I forgot to mention another change I made to the C1IOO model.
The location of the WFS global switch and the WFS_GAIN have been shifted. The switch now cuts off signals just before the WFS servo filters.
I have also added some test points just before the switch and the so that we can monitor the WFS error signals which would be unaffected even if the WFS_GAIN is changed..
Quote:
|
A while back we faced the problem that when we use several lockins to excite the MC degrees of freedom, their relative phase was not known. The solution suggested was to use one oscillator and several demodulators.
I have now modified the C1IOO.mdl so that this can be implemented. Previously we were using the MC_ASS lockins for WFS work. I have not separated the WFS and MC_ASS structures.
Other jobs to be done in this context are:
1) The medm screens associated with WFS lockins need to be updated with new channel names.
2) The scripts associated with both MC_ASS decentering and WFS ouput matrix determination have to be updated with the new channel names.
3) I also deleted all mdem screens in the $screens$/c1ioo/ directory after copying them to $screens$/c1ioo/bak/. After installing the new c1ioo model $screens$/c1ioo model now contains just the automatically created screens. All other user made screens should to into $screens$/c1ioo/master/ directory
This is a pic of the new c1ioo model:

|
|
5734
|
Tue Oct 25 11:48:02 2011 |
Katrin | HowTo | Electronics | solder tiny smd op amps |
Yesterday, I had the great pleasure to solder a tiny 4 x 4 mm op amp with 16 legs (AD8336).
I figured out that the best and fastest way to do it is
- to put solder with the soldering iron on every contact of the electronic board (top side)
- heat the bottom side of the electronic board with a heat gun
- use a needle to test if the solder is melted
- if it is melted place the op amp on the electronic board
- apply some vertical force on the op amp for proper contact and heat for 1 to 2 more minutes
- done
|
5733
|
Tue Oct 25 01:19:17 2011 |
Suresh | Update | Computers | fb restarted and c1ioo model committed to svn |
When I installed the new model I restarted the fb between 1 and 1:30 AM PDT Oct 25, 2011 |
5732
|
Tue Oct 25 01:14:15 2011 |
Suresh | Update | IOO | C1IOO model modified to include new WFS lockin structure |
A while back we faced the problem that when we use several lockins to excite the MC degrees of freedom, their relative phase was not known. The solution suggested was to use one oscillator and several demodulators.
I have now modified the C1IOO.mdl so that this can be implemented. Previously we were using the MC_ASS lockins for WFS work. I have now separated the WFS and MC_ASS structures.
Other jobs to be done in this context are:
1) The medm screens associated with WFS lockins need to be updated with new channel names.
2) The scripts associated with both MC_ASS decentering and WFS ouput matrix determination have to be updated with the new channel names.
3) I also deleted all medm screens in the $screens$/c1ioo/ directory after copying them to $screens$/c1ioo/bak/. After installing the new c1ioo model $screens$/c1ioo directory now contains just the automatically created screens. All other user made screens should go into $screens$/c1ioo/master/ directory
This is a pic of the new c1ioo model:

|
5731
|
Mon Oct 24 20:00:21 2011 |
Mirko | Update | CDS | Tiny little scripts |
Located in /opt/rtcds/caltech/c1/userapps/release/cds/common/scripts
Script 1: Diagreset.sh
Hits the diag reset buttons on the models on c1lsc and c1sus computers.
Script 2: Burtrest.sh
Restores the burt files from "today" 4am. Use a text editor if you want to change the times. |
5730
|
Mon Oct 24 19:48:16 2011 |
Mirko | Update | Adaptive Filtering | Filter execution time |
Toyed around some more with the adaptive filters.
Execution time:
nTaps Downsampling factor Execution time average / max in ca. 3 min [us], (480 us available)
1000 16 110 / 150
2000 16 280 / 340
3000 16 380 / 470
4000 16 Over limit
Now we are running with Downsampling 32, 4000 Taps => max 410us execution time.
I tried to desynchronize the downsampled operations of the filters of the different DOFs. That however increased execution time by about 10%. So I undid that.
|