Caryn | Summary | PEM | Filtering MC_L and MC_F with PEM:ACC and microphone |
Tried to filter MC_L and MC_F with acc/seis data and microphone data using wiener filter (levinson)
-Used get_mic_data.m and miso_filter_lev.m to make SISO filter for 2 minutes of IOO-MC_F data. Used PEM-AS_MIC signal as noise input data. Filters calculated at initial time were applied to later data in 1 hour intervals.
-microphone filter did not seem to filter MC_F very well in high frequency range using this filtering procedure.
-residual is larger than est (see MC_F pdf)
-Used do_all_time_lev.m to make graph of max(rms(residual)) to N(order) for different times.(note for each N, filter was calculated for initial time and then applied to data at other times).
-relation of max(rms(residual)) to N(order) is time sensitive (note-on graph, time interval is 1hour) (see MC_F pdf)
-Presumably, max(rms(residual)) should decrease as N increases and increase as time increases since the filter probably becomes worse with time. I think the reason this isn't always true in this case is that the max(rms(residual)) corresponds to a peak (possibly a 60Hz multiple) and the wiener filter isn't filtering out that peak very well.
-Used get_z_data.m and miso_filter_lev.m to make MISO filter for 2 minutes of IOO-MC_L used the following signals as noise input data
PEM-ACC_MC1_X
PEM-ACC_MC2_X
PEM-ACC_MC1_Y
PEM-ACC_MC2_Y
PEM-ACC_MC1_Z
PEM-ACC_MC2_Z
PEM-SEIS_MC1_Y
-Filter was applied to later data in 2hour intervals.
-Used do_all_time_lev.m to make graph of max(rms(residual)) to N(order) for different times.(note for each N, filter was calculated for initial time and then applied to data at other times).
-acc/seis filter seemed to filter MC_L OK for 128,256,512Hz srates. 64 Hz wasn't ok for certain N's after a period of time.
-residual is smaller than est for srates not 64Hz (see MC_L pdf)
-residual is larger than est for 64Hz at N=1448 for later times (see MC_L pdf)
-relation of max(rms(residual)) to N is not as time sensitive for higher sample rates (note-on graph, time interval is 2hours) (see MC_L pdf). Perhaps the levinson 64Hz sample rate filter doesn't do as well as time passes for these signals. When the filter didn't do well, the max(rms(residual)) seemed to increase with N.
-For 512Hz sample rate filter the max(rms(residual)) decreased with time. If the max(rms(residual)) were an indication of filter performance, it would mean that the 512Hz filter calculated at the initial time was performing better later as hours passed by! Perhaps max(rms(residual)) isn't always great at indicating filter performance.
Programming notes
-I had to modify values in do_all_time_lev.m to get the program to loop over the srates,N's,times I wanted
-do_all_time_lev.m is not as clean as do_all_lev.m
-for making the plots do_all_lev.m (which isn't really a procedure and is messy) has some examples of how to plot things from do_all_time_lev.m. |
Attachment 1: MC_F.pdf
|
|
Attachment 2: MC_L.pdf
|
|
Attachment 3: miso_filter_lev.m
|
function [s] = miso_filter_lev(N,srate,rat,z)
%MISO_FILTER_LEV(N,srate,z) uses miso_firlev to get levinson
% FIR Wiener filter of order N-1, using impulse response of
% N/srate. z is a structure gotten from the get_data function.
% z(end) is the signal which is filtered using z(i) for all i.
% 'rat' is the fraction of z which will be put into filter
% funtion. The data from z is downsampled using srate and
% detrended. Let rat=1. I don't have that part working yet.
... 107 more lines ...
|
Attachment 4: get_mic_data.m
|
function[z,t0,duration]=get_mic_data(t,d_t,d)
%get_mic_data gets data for'C1:IOO-MC_F', 'C1:PEM-AS_MIC,
% Example: z = get_mic_data('now',120,60)
% start time is 't- d_t' so d_t should be given in seconds. t should be given
% as a number like 893714452. d is duration in seconds. get_mic_data saves
% data to a file in current directory named 'temp_mic'. You will be asked to
% save file as 'mic_(start_time)_(duration)'.
duration = d;
... 32 more lines ...
|
Attachment 5: do_all_time_lev.m
|
function[r] = do_all_time_lev(n,t0,int,duration,N,srate,rat,order,time,MC_L,MC_F,sample_rate)
%do_all_time explores how filter performance changes with time, sample rate,
%and order of filter. Outputs data,noise estimate, structure of max
%rms error and other info. It uses get_data, miso_filter_lev, and miso_filter_int and retrives
%MC_Ldata or MC_Fdata for multiple times, calculates a miso_filter for initial-time data
%file, applies filter to the other data files, and keeps track of the...
%max(rms(residual)) for each filter. n+1 is number of data files. int is time interval between
%data files, t0 is start time, duration is duration of each data file, srate
%is the sample rate for which filter is calculated, n_N is number of orders
%of the filter you want the program to calculate,int_N is interval by which N
... 215 more lines ...
|
Attachment 6: do_all_lev.m
|
function[r] = do_all_lev(n,t0,int,duration,n_N,int_N,n_srate,int_srate,rat,MC_L,MC_F)
%do_all_lev explores how filter performance changes with time, sample rate,
%and order of filter. Outputs data,noise estimate, structure of max
%rms error and other info. It uses get_data, miso_filter_lev, and miso_filter_int and retrives
%MC_Ldata or MC_Fdata for multiple times, calculates a miso_filter for initial-time data
%file, applies filter to the other data files, and graphs the rms of the cost
%function vs time. n+1 is number of data files. int is time interval between
%data files, t0 is start time, duration is duration of each data file, srate
%is the sample rate for which filter is calculated, n_N is number of orders
%of the filter you want the program to calculate,int_N is interval by which N
... 283 more lines ...
|
Attachment 7: do_all_plot.m
|
function[r] = do_all_plot(r,x,v)
%do_all_plot plots variables contained in r(structure from
%do_all_time_lev).Plots error(r.B.y) vs x. x can be
%'s'(srate),'N'(order),'t'(time),'p'(impulse response). v can be 's','N','t'.
%example: do_all_plot(r,'s','t') makes a plot of error vs srate for
%different times.
kk=1
err_N_srate=0
... 388 more lines ...
|
Attachment 8: miso_filter_int.m
|
function [s] = miso_filter_int(s,y)
%miso_filter_int inputs a filter and a structure array of data sets y, applies filter to data, and
%outputs a structure with fields: ppos(signal frequ spectrum),perr(cost
%function frequ spectrum),pest(signal estimate frequency
%spectrum),f(frequency),target(signal),est_darm(noise estimate),t(time).
%data file for which filter has been calculated is s (obtained using miso_filter).
%y consists of data structures which will be filtered using
%filter from s. Then the power spectrum of the difference between signal and filtered-data is
%graphed for all the data files of y for comparison too see how well filter performs
%over time. Note if you want to create a y, take z1,z2,z3,etc. structures
... 120 more lines ...
|
521
|
Thu Jun 5 13:35:23 2008 |
josephb | Configuration | Cameras | GC750 looking at 1064nm scattered light |
I've taken 200 images of the GC750 (CMOS) camera while holding it by hand up to a beam card (also held by hand) in the path of ~5mW of beam power. I then averaged the images to produce the fourth attached plot.
Rob has pointed out the image looks a lot like PCB traces. So perhaps we're seeing the electronics behind the CMOS sensor?
I repeated the same experiment with HeNe laser light (again scattered off a card). These show none of the detailed structure (just what looks to be a large reflection from the card moving around depending on how steady my hand was). These are the first 3 attached plots. So only 1064nm light so far sees these features.
As a possible solution, I did a quick and dirty calibration by dividing a previous PSL output beam by the 1064 average scatter light values. These produce the last attached pdf (with multiple images). The original uncalibrated image is on top, while the very simply calibrated image is on the bottom of each plot.
It seems as the effect may be power dependent (which could still be calibrated properly, but would take a bit more effort than simply dividing), as determined by looking at the edges of the calibrated plot. |
Attachment 1: GC750_HeNe_scatter_avg.pdf
|
|
Attachment 2: GC750_HeNe_scatter_avg2.pdf
|
|
Attachment 3: GC750_HeNe_scatter_avg3.pdf
|
|
Attachment 4: GC750_scatter_avg.pdf
|
|
Attachment 5: GC750_nitrogen_white.pdf
|
|
520
|
Thu Jun 5 10:46:26 2008 |
josephb | Configuration | Cameras | Approximately uniform reflected white light |
In an attempt to investigate the structures seen in previous images for the GC750, I aimed it at a relatively clean section of gray table top roughly a cm or two from the surface and took images (without a lens). As I was holding this with my hand, the angle wasn't completely even with the table, and thus there's a gradient of light in the pictures. However, one should in principle be able to pick out features (such as a circular spot with less sensitivity), but these do not show up.
In my mind, these images seem to indicate the electronics are fine, and suggest that the CMOS or CCD detectors themselves are undamaged (at least in regards to white light, as opposed to 1064nm). An issue with the plastic cap (protective piece) may be the culprit, or perhaps a tiny bit of dust, which the incoherent light from all angles goes around efficiently?
Will try blowing the cameras with clean nitrogen today and see if that removes or changes the circular structure we have seen. |
Attachment 1: GC650_white_light.pdf
|
|
Attachment 2: GC750_white_light.pdf
|
|
519
|
Wed Jun 4 16:57:12 2008 |
josephb | Configuration | Cameras | Dark images from cameras (electronics noise measurement) |
The attached pdfs are 1 second and 1 millisecond long integrations from the GC650 and GC750 cameras with a cap in place - i.e. no light.
They include the mean and standard deviation values.
The single bright pixel in the 1 second long exposure image for the GC650 seems to be a real effect. Multiple images taken show the same bright pixel (although with slightly varying amplitudes).
The last pdf is a zoom in on the z-axis of the first pdf (i.e. GC650 /w 1 sec exposure time).
I'm not really sure what to make of the mean remaining virtually fixed for the different integration times for both cameras. I guess 0 is simply offset, but doesn't result in any runaway integrations in general. Although there are certainly some stronger pixels in the long exposures when compared to the short exposures.
Its interesting to note the standard deviation actually drops from the long exposure to the short exposure, possibly influenced by certain pixels which seem to grow with time.
The one with the least variation from its "zero" was the 1 millisecond GC750 dark image. |
Attachment 1: GC650_1sec_dark.pdf
|
|
Attachment 2: GC650_1msec_dark.pdf
|
|
Attachment 3: GC750_1sec_dark.pdf
|
|
Attachment 4: GC750_1msec_dark.pdf
|
|
Attachment 5: GC650_1sec_dark_zoom.pdf
|
|
518
|
Wed Jun 4 16:25:06 2008 |
Caryn | Summary | PEM | microphone moved |
The microphone 'C1:PEM-AS_MIC' has been moved right a bit. This change didn't seem to have much effect on filtering the 'C1:IOO-MC_L' signal, at least not compared to how the filter changes with time. Also used microphone data to filter MC_L data using firwiener filter/levinson. The N(order) and sample rate were varied to see how the filter changed. Attached are graphs of the max(rms(noise_estimate)) vs N or IR for varying srate. Note that filtered_signal=signal-noise_estimate. So, the larger the noise_estimate, the more the filter subtracts from the signal.
Green-filtered signal
blue-noise estimate
red-MC_L signal
note decreasing sample rate is more effective than increasing N (higher N takes more time to compute)
note sample rate doesn't change the max(rms(noise_estimate)) very much if impulse response time remains constant
note the 64hz, N=7000 (impulse response about 110s) filter is a better filter than the 512Hz, N=7000(impulse response about 14s) |
Attachment 1: 1_MC_L.pdf
|
|
517
|
Wed Jun 4 13:46:42 2008 |
josephb | Configuration | Cameras | Changing incident angle images |
Attached are images from the GC650 and GC750 when the incident angle was varied from 0 tilt (normal incidence) to 5,10, and 20 degrees. Each time the beam was realigned via the last turning mirror to be on roughly the same spot. This light was a pickoff of the PSL table light just before it leaves the table.
Images include the raw data, fit to the data, residual normalized by peak power "w(1)", and normalized by the individual bin power.
The first pdf includes 0 degrees (normal) and ~5 degrees of tilt for the GC650 (CCD) camera.
The second pdf includes ~10 and ~20 degrees of tilt images for the GC650 (CCD) camera.
The third pdf includes 0 and ~5 degrees of tilt for the GC750 (CMOS) camera.
The fourth pdf includes ~10 and ~20 degrees of tilt for the GC750 (CMOS) camera.
Things to note:
1) GC750 camera seems to have a structure on the camera itself, somewhat circular in nature. One possible explanation is the camera was damage at a previous juncture due to too much light. Need to check earlier images for this problem.
2) GC650 has "bands" which change direction and thickness with angle. Also at higher incidence angle, the sensitivity seems to drop (unlike the GC750 where overall power level seems to stay constant with increasing angle of incidence).
3) GC650 seems to have a higher noise floor,seen from the last plot of each pdf (where each pixel of the residual is normalized by the power in the corresponding pixel of the fit). |
Attachment 1: GC650_0dg_5dg.pdf
|
|
Attachment 2: GC650_10dg_20dg.pdf
|
|
Attachment 3: GC750_0dg_5dg.pdf
|
|
Attachment 4: GC750_10dg_20dg.pdf
|
|
516
|
Wed Jun 4 10:18:52 2008 |
steve | Update | PSL | wedged SS beam trap |
I moved the SS trap over to the psl table.
Texas super # 8 was used from the large shipment.
TXs#8 scattering measured as before, meaning the polishing is good.
Go's squeezing power pick up 350 mW was used.
I made two ~30 degrees wedge traps using 6" x 4" and 12" x 4" SS 0.039" thick
with copper backing of similar size.
There was too much scattering and I could not minimize them all.
It is very helpful to have so much space on the psl table.
It shows more of the weakness of this kind of trap.
I did not dare to turn up the power. |
Attachment 1: trap1.png
|
|
Attachment 2: trap2.png
|
|
515
|
Tue Jun 3 12:33:36 2008 |
Andrey | Update | Cameras | Andrey, Josephb |
Continuing our work with cameras,
1) we removed both cameras from their places on Monday afternoon, and were taking the beam-scans with a special equipment (see elog-entry 511) from Bridge bld.,
2) and on Tuesday morning we putted back the GC-750 camera into the transmitted beam path, camera GC-650 into the reflected beam path. We plan to compare the images from the "reflection camera" for several different angles of tilt of the camera. |
514
|
Tue Jun 3 10:40:27 2008 |
tobin | Configuration | Computers | new dataviewer |
Alex let me know the secret location of the latest dataviewer executable for Linux. It is:
http://www.ligo.caltech.edu/~aivanov/upload/dv/Control/dc3
If your linux dataviewer on linux2 has the "year field not filled in" bug, you should download this into /usr/local/bin/dc3 (after making a backup of that file).
It looks like there's no dataviewer installed on rosalba yet. We should figure out a better directory layout for the linux machines; currently dataviewer is installed locally on linux2. It should be in /cvs/cds/caltech/apps/linux/something so that all the linux machines see the same installation. |
513
|
Tue Jun 3 10:19:45 2008 |
tobin | Configuration | Computers | big machine |
Several of us transported the big new awesome Sun box from Bridge over to
the 40m last week. If I recall correctly, it's a SunFire X4600 with
something like sixteen 64-bit AMD processor cores at 2.8 GHz. It sounds
like a jet engine when it starts up (before the cooling fans are throttled
back) and has four power supplies (each with its own connection
to the wall). It has slick removable hard disks and fan units too. Our
working name for it is "megatron".
Anyway. It came with two hard disks, one with Solaris 10 installed. I took
the other hard disk over to Alex, who copied a Realtime Linux installation
onto it. Alex says it boots and runs fine.
It remains for you guys to install the machine onto rails and install the
whole thing into a rack. Before it goes into service as a realtime control
machine, you might as well install Matlab on it and do some heavy-duty
computation.
 |
512
|
Tue Jun 3 02:15:29 2008 |
Andrey | Summary | Cameras | Fitting results |
There have been a lot of work going on related to the processing of images captured by the cameras GC-650 and GC-750 recently.
In the end of the week of May 30 Joseph and me (Andrey) installed the two cameras capturing the images of the pick-off of the main beam on the PSL optical table. The cameras are located after the picked-off beam going towards the "PSL position QPD", after the 33-66 beamsplitter (33% of reflection and 66% of transmission).
Initially (on May 30) the GC-650 camera was taking the images of reflected beam, while the camera GC-750 was taking images of transmitted beam. On Monday June 2 we switched the positions of the cameras, so GC-650 appeared to be on the path of the transmitted beam and GC-750 on the path of the reflected beam.
I (Andrey Rodionov) was able in the weekend to succeed in writing a Matlab program that performs the two-dimensional Gaussian fitting of the captured images, and I used that program to fit the images from the cameras.
The program fits the camera data by a two-dimensional Gaussian surface:
Z = A * exp[ - 2 * (X - X_Shift)^2 / (Waist_X)^2 ] * exp[ - 2 * (Y - Y_Shift)^2 / (Waist_Y)^2 ] + CONST_Shift,
where A, X_Shift, Waist_X, Y_Shift, Waist_Y, CONST_Shift are 6 parameters of the fit.
Attached are the pdf-files showing the results: images taken with our cameras, the 2-dimensional Gaussian fit for these images and the surfaces of residuals. Residuals are differences between the exact beam profile and the result of fitting. In normalized version of residual graph I normalize it by the first coefficient of fitting A, the factor in front of the exponents. |
Attachment 1: May30-GC650.pdf
|
|
Attachment 2: May30-GC750.pdf
|
|
Attachment 3: June02-GC650.pdf
|
|
Attachment 4: June02-GC750.pdf
|
|
511
|
Mon Jun 2 12:20:35 2008 |
josephb | Bureaucracy | Cameras | Beam scan has moved |
The beamscan has been moved from the Rana lab back over to the 40m, to be used to calibrate the Prosilica cameras. |
510
|
Sun Jun 1 19:39:35 2008 |
tobin | Configuration | Computers | elog, etc |
Phil Ehrens gave me a DVD of the 40m elog, apache, and (Jamie's) SVN archive.
I copied it to nodus:/home/controls/dvd-from-ehrens. Once we get the elog
running on nodus, we can copy the datafile over again from dziban (so that
we don't lose any elog entries) and switch over. |
509
|
Sun Jun 1 19:25:10 2008 |
rana | Configuration | Computers | new monitor on op440m |
I installed the new 24" flat screen on op440m. I increased the screen resolution from 1280x1024 to 1900x1200 using
the obscure 'fbconfig' command. You can type Google it if you want.
The old monitor is on the surplus cart. If you are reading this and think you might walk from the 40 over to
Bridge, please wheel the cart full of old computer equipment (on the north side of the control room) over to Larry.
I also copied over all the images on the D40 to a folder on Kirk's computer and deleted the originals.
Dan Busby also visited us last week to help us move the drill press from the Y arm down into the sub basement
of W Bridge. |
Attachment 1: Andrey-440.jpg
|
|
Attachment 2: Busby08.jpg
|
|
508
|
Fri May 30 21:30:15 2008 |
tobin | Configuration | Computers | svn on solaris |
I installed svn on op440m. This involved installing the following packages from sunfreeware:
apache-2.2.6-sol9-sparc-local libiconv-1.11-sol9-sparc-local subversion-1.4.5-sol9-sparc-local
db-4.2.52.NC-sol9-sparc-local libxml2-2.6.31-sol9-sparc-local swig-1.3.29-sol9-sparc-local
expat-2.0.1-sol9-sparc-local neon-0.25.5-sol9-sparc-local zlib-1.2.3-sol9-sparc-local
gdbm-1.8.3-sol9-sparc-local openssl-0.9.8g-sol9-sparc-local
The packages are located in /cvs/cds/caltech/apps/solaris/packages. The command line to install
a package is "pkgadd -d " followed by the package name. This can be repeated on nodus to get
svn over there. (Kind of egregious to require an apache installation for the svn _client_, I
know.) |
507
|
Fri May 30 12:37:45 2008 |
rob | Update | SUS | etmy oplev is back |
Quote: | I relayed the optics for ETMY-oplev as shown in pictures below.
The reflected beam goes directly to the qpd |
I turned on the servo. UGFs in PIT and YAW are ~3Hz. I had to flip the sign of the YAW. |
506
|
Fri May 30 12:03:08 2008 |
josephb, Andrey | Configuration | Cameras | Head to head comparison of cameras |
Andrey and myself - Joseph B. - have examined the output of the GC650 (CCD) and GC750 (CMOS) prosilica cameras. We did several live motion tests (i.e. rotate the turning mirror, move and rotate the camera, etc) and also used a microscope slide to try to eliminate back reflections and interference.
Both the GC650 and GC750 produce dark lines in the images, some of which look parallel, while others are in much stranger shapes, such as circles and arcs.
Moving the GC750 camera physically, we have the spot moving around, with the dark lines appearing to be fixed to the camera itself, and remain in the same location on the detector. I.e. coming back to the same spot keeps showing a circle. In reasonably well behaved sections, these lines are about 10% dips in power, and could in principle be subtracted out. Its possible that the camera was damaged with too much light incident in the past, although going back to the pmc_trans images that were taken, similar lines are still visible.
Moving the GC650 camera physically seems to change the position of the lines (if one also rotates the turning mirror to get to the same spot on the CCD). It seems as if a slight change in angle has a large effect on these dark bands, which can either be thin, or very large, bordering on the size of the spot size. My guess is (as the vendor suggested) the light is interacting with the electronics behind the surface layer rather than a surface defect producing these lines. Using a microscope slide in between the turning mirror and the GC650, we were able to produce new fringes, but didn't affect the underlying ones.
Placing a microscope slide in between the last turning mirror and the GC750 does not affect the dark lines (although it does seem to add some), nor does turning the final turning mirror, so it seems unlikely to be caused by back reflection in this case.
So it seems the CMOS may be more consistent, although we need to determine if the current line problems are due to exposure to too much light at some point in the past (i.e. I broke it) or they come that way from the factory.
Attached are the results of image-processing of the images from the two our cameras using Andrey's new Matlab script. |
Attachment 1: Waveform_Reconstruction_May30-2008.pdf
|
|
505
|
Thu May 29 16:49:49 2008 |
steve | Bureaucracy | Photos | Yoichi has arrived |
Yoichi had his first 40m meeting. We welcomed him and Tobin, who is visiting, by sugar napoleons that
Bob made. |
Attachment 1: yoichi.png
|
|
Attachment 2: bobsn.png
|
|
504
|
Thu May 29 16:32:09 2008 |
steve | Update | SUS | etmy oplev is back |
I relayed the optics for ETMY-oplev as shown in pictures below.
The reflected beam goes directly to the qpd |
Attachment 1: P1020417.png
|
|
Attachment 2: P1020420.png
|
|
503
|
Thu May 29 15:58:44 2008 |
John | Summary | IOO | MC realignment |
I repeatedly adjusted the yaw of the upper mirror on the input periscope and re aligned the MC. With the PRM aligned I tried to optimise MC transmission and DC refl simultaneously. I subsequently centred the beams on WFS1/2. Attached is a 30 day trend of MC alignment and transmission. |
502
|
Wed May 28 14:19:47 2008 |
steve | Update | PSL | kaleidoscope of psl |
atm 1: scattering psl table optics from the top of the output periscope f4, 60s @MOPA 3 W
atm 2: scattering psl table optics from the top of the output periscope f4, 20s
atm 3: competing GigE cameras on the north end of psl table
atm 4: yellow "soft" washer to be replaced on psl output periscope
atm 5: ETMY-ISCT in disarray |
Attachment 1: pslscat.png
|
|
Attachment 2: pslscat2.png
|
|
Attachment 3: 2GigEs.png
|
|
Attachment 4: perwash.png
|
|
Attachment 5: etmydisarray.png
|
|
501
|
Wed May 28 12:51:32 2008 |
josephb | Configuration | Computers | Two more switches mounted |
Two more Prosafe 24 port switches have been mounted in the racks, one in 1Y9 and one in 1Y6. (The first one was placed in 1X4).
The one in 1Y9 has been set to an IP address of 131.215.113.251, while the one in 1Y6 is set to 131.215.113.252, and these have been labeled as such. |
500
|
Tue May 27 16:24:54 2008 |
tobin | Configuration | Computer Scripts / Programs | ndsproxy |
The NDS Proxy is a program that accepts NDS (LIGO Network Data Server) connections from the internet and relays them to
our internal frame-builder, so that you can get DAQ and test-point channel data from off-site.
I stopped the ndsproxy that was running on rana and started it on nodus, its new home. This will be
documented in the wiki.
So far I haven't found a mechanism by which the ndsproxy was restarted automatically on rana. Has it just been
restarted by hand?
The ndsproxy stuff lives in target/ndsproxy. Restarting it seems to be just a matter of running "start_ndsproxy" in
that directory. |
499
|
Sun May 25 22:33:00 2008 |
rana | Update | SUS | ETMY Oplev Work |
I found the ETMY table in disarray and put the panels back on and put the ETMY OL laser back on the quad.
The next thing to do is clean up the table (there's a lot of junk on it) and then put in a lens within
6" of the laser to focus the beam on the quad (no metal diving boards and the lens should be either
uncoated (from our Edmunds collection) or a red lens, not 1064).
Then we have to put the beam cover back on between the viewport and the table. |
498
|
Sun May 25 21:14:14 2008 |
tobin | Configuration | Computers | EPICS proxy server |
I set up an EPICS gateway server on Nodus so that we can look at 40m MEDM screens from off-site.
The gateway is set up to allow read access to all channels and write access to none of them.
The executable is /cvs/cds/epics/extensions/gateway; it was already installed. A script to start
up the gateway is in target/epics-gateway. For the time being, I haven't set it up to start itself
on boot or anything like that.
To make it work, you have to set the environment variable EPICS_CA_ADDR_LIST to the IP address of
Nodus. For instance, something like this should work:
setenv EPICS_CA_ADDR_LIST 131.215.115.52
On Windows you can set up environment variables in the "System" Control Panel. On one of the tabs
there's a button that lets you set up environment variables that will be visible to all programs.
On Andrey's machine I installed the Windows EPICS extensions, i.e. MEDM and its friends. I also
installed the cool Tortoise SVN client which lets you interact with SVN repositories through
the windows explorer shell. (The right-click menu now contains SVN options.) I checked out
the MEDM directory from the 40m SVN onto the desktop. You should be able to just right-click in
that window and choose "SVN Update" to get all the newest screens that have been contributed to
SVN; however, there are currently some problems with the 40m SVN that make that not go smoothly.
At the moment on Andrey's (Windows) machine you can go into the MEDM folder and double-click on
any screen and it will just work, with the exception that not all the screens are installed
due to SVN difficulties. |
497
|
Sun May 25 20:30:25 2008 |
rana | Summary | PSL | PMC Mode Matching |
I checked the PMC mode matching by ramping the gain down to -10 dB (from +20 dB) and
moving the DC offset around until it caught lock on the different HOMs. Then I recorded
the output power (PMCTRANSPD). The DC offset on this EPICS channel was -0.013 V, so I
used its AOFF field to zero this out. Here is a list of the power in the largest modes:
Mode Power (V)
---- ---------
00 2.7
10 0.2
04 0.04
02 0.02
BE 0.36 **Bull's Eye mode is TEM02 + TEM20. This can be fixed by lens adjustment.
N.B. To make a PNG file with DTT, just make an EPS file -- then use the eps2png perl script. |
Attachment 1: pmc.png
|
|
496
|
Sun May 25 19:33:16 2008 |
rana | Update | IOO | MC Bad after Re-alignment |
The MC pointing was off and the transmitted power was down after John and Andrey brought it back after the bootfest.
I tried getting it back on Friday but was unsuccessful. Today, after the Phoenix Landing, I got it back to someplace
reasonable, but it still seems to be far off. I will check with Rob before we recenter and of the QPDs.
I had to move all of the MC SUS and also align the beam using the IOO periscope. The attached PDF shows some trends
over the last 80 days. You can see that the drop in MC TRANS is about the same as the drop in PMC TRANS. |
Attachment 1: e.pdf
|
|
Attachment 2: pmc.png
|
|
495
|
Sun May 25 16:20:27 2008 |
rana | Configuration | Computers | joinPDF |
I have installed joinPDF 2.1 on rosalba. Since its written in Java, I didn't have to tinker with it at all to work on a 64-bit machine. Now Caryn can put all of her plots into 1 file. |
494
|
Fri May 23 21:21:52 2008 |
Caryn | Summary | General | filtering mode cleaner with wiener filter |
I tried filtering some saved MC_L data (from Mon May19 4:30pm) with multiple MISO filters of different orders, with various sampling rates, at different times. Plotted the max rms error (where error is signal minus signal-estimate). 2min of data (around Mon May19 4:30pm) were used to calculate each filter. And each filter was applied to data at later times to see how well it performed as time progressed. Plots are attached. There appears to have been a disturbance during the 3rd hour. Rana pointed out perhaps it would be better to use data from the evening rather than during the day. |
Attachment 1: error_vs_N_for_different_times_64Hz.pdf
|
|
Attachment 2: error_vs_N_for_different_times_128Hz.pdf
|
|
Attachment 3: error_vs_N_for_different_times_256Hz.pdf
|
|
Attachment 4: error_vs_N_for_different_times_512Hz.pdf
|
|
Attachment 5: error_vs_srate_for_different_times_256.pdf
|
|
Attachment 6: error_vs_srate_for_different_times_512.pdf
|
|
Attachment 7: error_vs_srate_for_different_times_1024.pdf
|
|
Attachment 8: error_vs_time_for_different_srates_256.pdf
|
|
Attachment 9: error_vs_time_for_different_srates_512.pdf
|
|
Attachment 10: error_vs_time_for_different_srates_1024.pdf
|
|
493
|
Fri May 23 08:24:24 2008 |
rana | AoG | Treasure | Yoichi Aso has arrived ! |
|
Attachment 1: Colossus_back_(800_x_600)-thumb.jpg
|
|
492
|
Thu May 22 11:25:19 2008 |
josephb | Configuration | Computers | |
One of the new Netgear Prosafe 24 port switches was mounted in the 1X4 rack,, roughly in the middle, away from the top and bottom rack mounted electronics. At the moment, its IP has been set to 131.215.113.250, gateway 131.215.113.2 (which is what I saw as the only listed gateway on linux1 using route -n) and mask 255.255.255.0.
I'm planning to set the next three IP address for the switches as *.251, *.252 and *.253, which don't look to have been used yet. |
491
|
Thu May 22 11:21:45 2008 |
steve | Bureaucracy | SAFETY | early surf sudent |
Caltech under grad Eric Mintun received the 40m safety training.
Now he has to read and sign SOP of laser and ifo.
He'll be working with GigE cameras with Joe |
490
|
Wed May 21 15:21:33 2008 |
rob | Update | Computer Scripts / Programs | autolockers and cron |
I added hourly cron jobs to op340m to ensure that
MC autolocker
FSS Slow Servo
PSL watch
are running. I've also edited the wiki procedure to reflect the fact that these no longer need to be restarted by hand. |
489
|
Tue May 20 18:33:01 2008 |
Andrey, John | Configuration | IOO | Mode Cleaner is locked again |
It was noticed by Mr.Adhikari earlier today that the MC became unlocked at about 11AM.
There is no clear understanding what caused the problem.
Trying to restore the modecleaner locking, we noticed with John that the beam was not centered on the wavesensors (WFS1. WFS2 on the screen "C1IOO_LockMC.adl"). We decided to adjust the beam position moving slightly the bias sliders for pitch and yaw degrees of freedom for MC1.
This allowed to make the MC locked.
Old positions for the MC1 sliders: Pitch = 2.9934, Yaw = -0.6168;
New positions --------//---------: Pitch = 3.0604, Yaw = -0.7258.
At the same time, FSS for PSL is still showing the values in the range 0.720 - 0.750 which is lower than the usual values. The indicator for FSS value is yellow when it is below 0.750. |
488
|
Tue May 20 09:28:42 2008 |
steve | Bureaucracy | SAFETY | safety traning for 40m |
Tara Chalernsongsak, new gradstudent for K. Libbrecht was introduced to the basics of the 40m operations. |
487
|
Mon May 19 11:49:57 2008 |
steve | Update | SUS | etmy oplev laser replaced |
The 9 years old Uniphase HeNe was replaced by a new JDSU 1103P
Power output ~3.5 mW, reflected light back on qpd ~140 microW, 12,800 counts
Andrey will get the ~2.5 mm od spot on the qpd smaller by replacing
the f1000 lens |
486
|
Sun May 18 18:59:15 2008 |
rana | Configuration | Computers | cron and hosts |
I added rosalba to the hosts file for the control room machines (131.215.113.103).
I also removed the updateddb cron from our op440m crontab because it was running at 5 PM
even though I had set it to run at 5:57 AM. If it still runs then, it must be because of
another crontab. |
485
|
Sun May 18 18:44:48 2008 |
rana | Summary | SUS | Optical Lever SUM Trend - 80 days |
I used the OL-Trend.xml dataviewer template to make this plot. Looks like the ETMY optical lever
slowly degraded over the last few months and then finally died 10 days ago. Would someone please
replace this laser and tune the lens position to minimize the spot size on the quad? |
Attachment 1: e.pdf
|
|
484
|
Sun May 18 18:14:30 2008 |
rana | Summary | Computer Scripts / Programs | autlockers and cron |
Today I noticed that the MC was unlocked, the MC autolocker was off, the PSL autolocker was off,
and the PSL Slow loop was off.
Reading through .log files and our elog it seems like things have been this way since Tuesday
when Andrey went around rebooting computers to bring things back.
And it looks like the ETMY optical lever is dead.
I restarted the PSL & MC scripts on op340m. I also locked and aligned the X arm to verify that
not everything is broken. The Y Arm is unalignable until we replace the HeNe. |
483
|
Fri May 16 17:27:55 2008 |
Andrey | Omnistructure | General | Toilets are broken, do not use them !!! |
Both toilets in 40-meter were constantly flushing, the leaking water was on the floor inside of the restrooms, so
BOTH RESTROOMS ARE CLOSED TILL MONDAY
I have heard the constant loud sound of flushing water, opened the door, and was unpleasantly surprised because all the floor was under the layer of water and the toilets were constantly flushing. I called security at X5000, a plumber came in and told that a team of plumbers needs to repair the flushing system after the weekend. The plumber today just shut off the flushing water, wiped off the floor and told not to use the restrooms in the weekend. We should expect a team of plumbers on Monday.
Sinks are working, so you can wash your hands. |
482
|
Fri May 16 14:38:50 2008 |
josephb | Summary | Cameras | Two cameras setup |
I've changed the pickoff setup from yesterday for the GigE cameras to include a 33% beam splitter (first one I could find). The reflection is going to the GC650 (CCD camera) while the transimission is going to the GC750 CMOS camera. This means the CMOS camera has roughly twice the light incident as the GC650 and should be kept in mind in all comparisons. The distances from the beam splitter are approximately the same both cameras, but some more accurate positioning might be useful.
Its very easy to get the GC650 camera into a bad state where you need to go out and cycle the power (simply unplug and re-plug in the power supply either at the camera or outlet). If the ListCamera program doesn't see it, this is probably necessary.
Andrey added at 6.30PM: Actually the 650 camera keeps crashing constantly. Every time I attempt to capture an image, the camera fails. |
481
|
Thu May 15 16:24:18 2008 |
josephb | Summary | Cameras | |
The GC750 camera is currently looking at a very small pickoff of the PSL output (transmission of a Y1-1037-45-S mirror). The plan is to take images tomorrow with it and the GC650 from the same spot and do comparisons.
For those interested, the camera can be run with two codes, from mafalda. Use ssh -X mafalda to login, to allow the live stream to work with the SampleViewer code. The codes can be found in:
/cvs/cds/caltech/target/Prosilica/40mCode/Snap
and
/cvs/cds/caltech/target/Prosilica/bin-pc/x86/SampleViewer
Type Snap --help for a list of options for that program. Click the circle looking thing in SampleViewer to start the live stream. Note only 1 of the two programs can be running at a time, and the only way to change settings (such as exposure length) is with Snap at the moment. |
480
|
Thu May 15 14:39:33 2008 |
Caryn | Summary | PEM | filtering mode cleaner with mic |
Tried filtering for mode cleaner data(C1:IOO-MC_L) using a siso-firwiener filter and microphone data(C1:PEM-AS_MIC) for noise input. The noise reduction in mode cleaner data using the microphone-filter is comparable to the noise reduction when an accelerometer(C1:PEM-ACC_MC1_X) filter is used. See attached graphs. |
Attachment 1: MC_L_with_PEM-AS_MIC_filter.pdf
|
|
Attachment 2: MC_L_with_PEM-ACC_MC1_X_filter.pdf
|
|
479
|
Thu May 15 12:05:49 2008 |
josephb | Configuration | PSL | Path to PSL Position QPD |
The 50/50 beamsplitter that was being used as the last turning mirror to the PSL Position QPD has been replaced with a Y1-1037-45-S plate. This turning mirror was also moved 4" farther along the beam path, so as to produce as small (few microwatts) transmission through the plate. The lensing optics were also shifted so as to maintain a focused beam on the photodiode. Lastly, the rotating ND filter was increased from 1.5 to 2.0 to reduce the incident power on the photodiode, since twice the power is now reaching it.
The small beam on transmission will be used by the digital cameras as a test beam. |
478
|
Thu May 15 10:40:21 2008 |
steve | HowTo | General | Lisa Goggin, PhD |
Lisa Goggin successfully defended her thesis on May, 13 2008
"A Search For Gravitational Waves from Perturbed Black Hole Ringdowns in Ligo Data"
She started out as a surf student in the 40m.
Congratulation! |
Attachment 1: lisa.JPG
|
|
477
|
Wed May 14 14:05:40 2008 |
Andrey | Update | Computers | Computer Linux-2, MEDM screen "Watchdogs" |
Computer "Linux-2", MEDM screen "C1SUS_Watchdogs.adl": there is no indication for ETMY watchdogs, everything is white. There is information on that screen "C1SUS_Watchdogs.adl" about all other systems (MC, ETMX,...), but something is wrong with indicators for ETMY on that particular control computer. |
476
|
Wed May 14 13:14:19 2008 |
Andrey | Summary | Computers | Reflective Memory Network is restored |
Reflective Memory Network is restored, all watchdogs and oplevs are returned to the "enabled" state.
In order to revive the computers, several things were done.
1) Following Mr. Adhikari's elog entry #353, I walked around the interferometer room, and switched off the power keys in all crates with computers whose names are contained in the MEDM Reflective Memory screen, including the rack with the framebuilder. By the way, it was nontrivial to find the switch in the 1Y4 crate that would shut off/on processors "c1susvme1" and "c1susvme2": the switch turned out to be located at the rear side of the crate, and it is not a key but it is a button.
2) I was trying to follow wiki-40 computer restart procedures, but every time that I was trying to run "startup.cmd" screen from the corresponding target subdirectory, I got the error message "Device or resource busy".
By the way, one more thing was learned: if you firstly open in terminal burtgooey, select the snap file, then reboot the processor, and then will try to burt-restore it, you will get the message "Status Not OK". In order to really burt-restore the processor which was recently rebooted, you need to close the terminal with burtgooey and open burtgooey in a new terminal window which should be opened after rebooting the processor.
Feeling that my activities according to wiki-40 procedures do not revive computers, I invited Alex Ivanov.
3) Alex tried to touch the memory card in "c1iovme" in rack 1Y2, because once before this card failed causing network problems, but this did not help.
4) We shutted off and restarted again (pressing the power-switching button) the black Linux machine "c1dcuepics" (located in the very bottom below the framebuilder). Alex says that this machine is responsible for all EPICS. It was not restarted for 182 days, and probably some process there went wrong.
After restarting this machine "c1dcuepics" we were able to follow wiki-40 procedures for restarting all other computers (whose names are on the MEDM RFM network). We ran correcponding "startup.cmd" files and burt-restored them without error messages.
Now all the computers work and communicate in a proper way.
Mr. Joseph Betzwiezer was helping me with all these activities (we decided that it is more important that cameras for now), thanks to him. But our joint skills turned out to be insufficient, so Alex Ivanov's contribution was the most important. |
475
|
Tue May 13 10:38:28 2008 |
steve | Update | Computers | rfm network is down |
The RFM network went down yesterday around 5pm
Only c1susvme1 is alive but it's timing is off.
Andrey is bringing the network up.
Andrey wants to make an addition first that our situation is very much similar to that described by Rana in his elog entry # 353 (March 03). All of the rectangular boxes are red, except for SUS1-c1susvme1 and AWG (only these two rectangles are green). |
474
|
Tue May 13 10:15:52 2008 |
steve | Update | SUS | restored damping of BS & PRM |
I think our janitor was cleaning too heavy handedly.
The BS and PRM sus damping were lost.
They were restored. |
473
|
Fri May 9 10:15:36 2008 |
josephb | Update | Computers | Nodus has moved |
Steve and myself moved Nodus from under the table in the control room, to just above the Rana computer in the control room rack. |