4711
|
Fri May 13 01:51:56 2011 |
Suresh | Update | RF System | RF Status update | I have posted the attached RF status update and 1Y2 rack layout to the svn. |
Attachment 1: 1Y2_Rack_Layout.pdf
|
|
Attachment 2: RF_Work_Status.pdf
|
|
4714
|
Fri May 13 22:45:37 2011 |
Suresh | Update | RF System | The full set of 8 Demod boards is ready for testing | We have Completed the hardware changes to the full set of 8 demod boards. The last one completed today is AS11. I have collected the info on all the demod boards available so far in the table below. As we measure the actual phase and amplitude unbalance we will expand this table to include new info.
The set of 8 demod boards
Demod Board |
S. No. |
Power Splitter |
Frequency range of splitter (MHz) |
Phase unbalance from datasheet (deg) |
Amplitude Unbalance from datasheet (dB) |
AS11 |
121 |
PSCQ-2-51W |
5 to 50 |
87.49 |
0.1 |
REFL11 |
021 |
PSCQ-2-51W |
5 to 50 |
87.49 |
0.1 |
POY11 |
119 |
PSCQ-2-32 |
3.2 to 32 |
87.58 |
0.05 |
AS55 |
029 |
PSCQ-2-51W |
5 to 50 |
no info |
no info |
REFL55 |
118 |
PQW-2-90 |
30 to 90 |
90.14 |
0.92 |
POY11 |
119 |
PSCQ-2-32 |
3.2 to 32 |
87.58 |
0.05 |
POY22 |
020 |
PSCQ-2-32 |
3.2 to 32 |
90.26 |
0.02 |
POY110 |
120 |
PSCQ--120 |
80 to 120 |
90.88 |
0.58 |
|
4715
|
Fri May 13 23:04:58 2011 |
Suresh | Update | RF System | DC power supply on RF distribution box has been replaced. | [Steve, Koji, Suresh]
We shifted two Sorensen power supplies from the Auxiliary rack next to 1X2 to 1Y2. And have installed them there (pic below). The local ground reference was picked up from the racks ground reference. A shielded cable with two twisted pairs was used to make a new power cable for the RF rack. Since we are using three of the four conductors (+18,+28 and ground), one of them is not connected to anything. This situation can be improved in a future iteration when, for example, we might wish to relocate the Sorensens to a different rack.
We are still working on changing the power supply to the RF source. Will complete this early next week

|
4716
|
Sat May 14 14:12:16 2011 |
Koji | Update | RF System | DC power supply on RF distribution box has been replaced. | Key points of the power supply installation
- We followed the grounding configuration for KEPCO except for the signal ground connection
- AC power supply has been obtained from the local power strip. This also provides chassis earthing (for safety)
- The chassis is connected to the shieldin of the DC supply cable. The other end should be isolated.
- The low voltage side of Sorensen's DC outputs are connected in order to share the same reference level.
- The ground level is provided from the cross connect. The cable is connected between the cross connect ground to the sorencen.
Unlike the KEPCO case, this cable does not have the current return, but just is to define the voltage level of those Sorensens.
- New AC&DC cables have been nicely strain-relieved.
Quote: |
[Steve, Koji, Suresh]
We shifted two Sorensen power supplies from the Auxiliary rack next to 1X2 to 1Y2. And have installed them there (pic below). The local ground reference was picked up from the racks ground reference. A shielded cable with two twisted pairs was used to make a new power cable for the RF rack. Since we are using three of the four conductors (+18,+28 and ground), one of them is not connected to anything. This situation can be improved in a future iteration when, for example, we might wish to relocate the Sorensens to a different rack.
We are still working on changing the power supply to the RF source. Will complete this early next week
|
|
Attachment 1: sorensen.png
|
|
4736
|
Wed May 18 07:13:00 2011 |
Suresh | Update | RF System | Demod board measurements | I measured the amplitude and phase imbalances of the demod boards which have been modified. This is just a basic health check. We hope to use the script that Kiwamu is developing for a more accurate test. The script can also use these measurements as a sanity check. POP110 requires some further attention.

The RF distribution box outputs corresponding to the demod board (eg. AS55_LO --> AS55_demod) were used as LO sources. The RF signal was generated with a Marconi and held a kHz away from the LO frequency. The amplitude and phase unbalance were measured with SR785. The RF Power meter was used to check the LO power in each case.
|
Attachment 1: Demod_Board_measurements.png
|
|
4737
|
Wed May 18 07:18:15 2011 |
Suresh | Update | RF System | POY55_Demod board Hardware change completed | The ~350 Hz noted in the elog below was traced to an RF modulation of the 11 MHz sideband. This modulation was set up in the Marconi which is currently supplying the 11 MHz local oscillator signal to the RF source. lt was used during the MC length study completed last week by Valera and Ryan. The frequency measured was 322 Hz.
As we do not require this any longer, I have switched off this modulation.
Quote: |
The Demod board with S. No. 022 (being used earlier as REFL11) has been modified. It now has SCLF-65 as its input LP filter on the PD input line and a PQW-2-90 power splitter. The unit functioning okay (I and Q signals are 90 deg apart.
The loss of Q output was traced to a possible loose solder joint and we now have both the I and Q signals after resoldering all components in the vicinity of U7 (Ref Schematic of D990511)
There is a strong oscillation around 350Hz present on I and Q signals of both REFL55_Demod and POY55_Demod. Don't know the source.
We have run out of power splitters to continue with the Demod board modification. We do not currently have an AS11_Demod board. All the others are in place and ready for the I<->Q phase angle measurement.
In summary we now have the following Demod boards in place:
[ REFL11, POY11, REFL55, AS55, POY55, POY22, POY110]_Demod
|
|
4738
|
Wed May 18 15:54:50 2011 |
Koji | Update | RF System | DC power supplies for the RF generation box in place | [Koji, Steve]
DC power supplies for the RF generation box are now in place. They are the top two of the 6 Sorensens in the OMC short rack next to 1X2.
We made the connections as we did for the RF distribution box, the power supplies labele, and the cables strain-relieved.
The power supply is not yet connected to the actual RF generation box. This should be done by Suresh or someone with the supervision of him.
Note:
We have two +18V supply on the short OMC rack, in total. One is for the RF source, the other is for the OMC PZTs, whitening, etc.
This is to avoid unnecessary ground loop although the grounding situation of the OMC side is not known to me. |
4739
|
Wed May 18 16:52:23 2011 |
Suresh | Update | RF System | Cables for AS11 PD are in place | [Larisa, Suresh]
All the cables needed for the AS11 PD are in place... the heliax cable runs from the AS table to the PSL rack. The LO and RF cables to demod board as well as the I and Q cables into the LSC Whitening board are connected.
The cables get rather densely packed when the LSC Whitening filter sits between the PD Interface Board and the LSC AA filter board. This makes it difficult to access the SMA connectors on the LSC whitening filter. So we shifted the LSC Whitening and AA Filter boards one slot to the right. The LSC rack looks like this just now. We have also shifted the binary cables at the back of the Eurocart by one slot so the same cables are associated with the cards.

|
4740
|
Wed May 18 17:06:39 2011 |
Suresh | Update | RF System | DC power supplies for the RF generation box in place |
I have checked the voltages on the connector. They are okay and I have plugged in the Sorensen power into the RF Source. The ground reference for the Sorensens comes from the 1X2 Rack ground reference lines on the south side of the rack.
I looked for the OMC ground reference. Could not find one on either of the the OMC half racks.
Quote: |
[Koji, Steve]
DC power supplies for the RF generation box are now in place. They are the top two of the 6 Sorensens in the OMC short rack next to 1X2.
We made the connections as we did for the RF distribution box, the power supplies labele, and the cables strain-relieved.
The power supply is not yet connected to the actual RF generation box. This should be done by Suresh or someone with the supervision of him.
Note:
We have two +18V supply on the short OMC rack, in total. One is for the RF source, the other is for the OMC PZTs, whitening, etc.
This is to avoid unnecessary ground loop although the grounding situation of the OMC side is not known to me.
|
|
4751
|
Thu May 19 19:41:17 2011 |
Suresh | Update | RF System | DAQ channel Assignments for RF PDs | [Kiwamu, Suresh]
In trying to keep the wiring of the LSC rack as neat as possible, we came up with the following channel assignments of the RF PD signals.
PDI = PD Interface, The PD Interface D-type connectors (#1 to #12) are numbered: Top -> Bottom and Left -> Right in ascending order.
The Analog channels on the LSC Whitening Filter boards are numbered similarly, 1 to 32 in four sets.

|
4755
|
Fri May 20 05:41:22 2011 |
Suresh | Update | RF System | Demod board measurements | The POP110 board which had the large Amplitude and Phase unbalances was examined today. It turned out that there was some stray solder which had connected the Sum port of the PSCQ-2-120 splitter to its body (ground). After I removed that the amplitude unbalance was 0.3dB however the phase was 105deg. The phase reduced to 90 deg only if the power on the splitter is around 19 dBm. So removed the AT1 (10dB attenuator) and the phase unbalance dropped to 91 deg. However this is not a sustainable solution as the ERA-5 max output is about 19.5 dBm.
As this is a side band power monitor (and not a length sensing RFPD), we can make do with a poorer phase. I will therefore replace the AT1 and adjust the residual phase with cable delay lines.
Quote: |
I measured the amplitude and phase imbalances of the demod boards which have been modified. This is just a basic health check. We hope to use the script that Kiwamu is developing for a more accurate test. The script can also use these measurements as a sanity check. POP110 requires some further attention.

The RF distribution box outputs corresponding to the demod board (eg. AS55_LO --> AS55_demod) were used as LO sources. The RF signal was generated with a Marconi and held a kHz away from the LO frequency. The amplitude and phase unbalance were measured with SR785. The RF Power meter was used to check the LO power in each case.
|
|
4804
|
Fri Jun 10 12:04:57 2011 |
Jenne | Update | RF System | Bad RF connections!! | I am in the process of calibrating AS55's shot noise, and I noticed that the AS55 PD input to the demod board was only finger-tight. I then checked all of the other SMA connections in the set of RF PD demod boards, and found several more that were loose, including all of the REFL55 connections. This is no good!!!! RF connections need to be tightened! I went through and tightened all of the offending connections with my personal Snap-on SMA wrench. |
4957
|
Fri Jul 8 19:50:19 2011 |
Suresh | Update | RF System | LSC rack channel assignment | [Jamie, Suresh]
We looked at the ADC channel assignments in the LSC model and wanted to make sure that the LSC rack wiring and the LSC model are in agreement with each other. So the plan is to wire the rack as shown below. I will also post this file on svn so that we can keep it updated in case there are changes.

|
5249
|
Tue Aug 16 16:59:20 2011 |
Anamaria | Update | RF System | AM in the PM | Kiwamu, Keiko, Anamaria
Looking at the I and Q signals coming from REFL11 and REFL55 we saw large offsets, which would mean we have amplitude modulation, especially at 11MHz. We checked the PD themselves with RF spectrum analyzer, and at their frequencies we see stationary peaks (even if we look only at direct reflection from PRM). We changed the attenuation of the PSL EOM, and saw the peak go down. So first check is beam out of PSL EOM, to make sure the input beam is aligned to the crystal axis and is not giving AM modulation in adition to PM. |
5251
|
Wed Aug 17 02:48:56 2011 |
kiwamu | Update | RF System | Re: AM in the PM | [Keiko / Suresh / Anamaria / Kiwamu]
The AM components do exist also on the beam after the EOM.
The peaks were found at 11, 29 and 55 MHz, where the PM are supposed to be imposed.
Suresh and Keiko minimized them by rotating the HWP, which is in front of the EOM.
Also Anamaria and I tried minimizing them by adjusting the EOM crystal alignment.
However everytime after we minimized the AM peaks, they grew back in a time scale of ~ 1 min.
Potentially it could be a problem of the HWP and/or EOM alignment.
Since we wanted to proceed the in-vac work anyways, we stopped investigating it and decided to postpone it for tomorrow.
We again adjusted the incident power to 20 mW.
-- P.S.
The incident power going to MC went down to 7 mW for some reasons. This was found after ~ 6 hours from our works on the PSL table.
We haven't touched anything on the PSL table since the daytime work.
Possibly the angle of the HWP is drifting (why?) and changed the amount of the P-polarizing beam power.
Suresh locked the angles of two HWPs, which are the one just after the EOM and the one after the attenuation PBS.
Quote from #5249 |
So first check is beam out of PSL EOM, to make sure the input beam is aligned to the crystal axis and is not giving AM modulation in adition to PM.
|
|
5278
|
Mon Aug 22 20:37:43 2011 |
Anamaria | Configuration | RF System | Plan for install of 3f PDs | I made a quick sketch of how to include two more RF PDs on the REFL beam, given the space we have on the table. We want to install REFL33 and REFL165, 3f signals for the the two modulation frequencies we are using. The point is to make the distance from first beam splitter the same to all PDs so that we can use only one lens before this BS to make the beam the right size. Currently there are 2 PDs on the refl beam, REFL11 and REFL55, predictably. So the drawing shows 4 PDs. Drawing is to scale but is a bit coarse. Hopefully we'll take pictures once we're done.
Reference from current BS splitting beam to the existing PDs. |
Attachment 1: 40m3fReflPdLayout.pdf
|
|
5921
|
Thu Nov 17 11:04:02 2011 |
Jenne | Update | RF System | Stochmon? | Is there an update on Stochmon? Are the signals acquired somewhere already? What's the current deal-io? The new EOM mount should be here later today, and I'm jazzed to start checking how my EOM box helps (hopefully) the amount of RFAM we see.
I'll start making the adapter plate while I wait... |
5923
|
Thu Nov 17 11:35:27 2011 |
Koji | Update | RF System | Stochmon? | The Stochmon channels for 11&55MHz have been reasonably working since last night.
The output is not yet calibrated as the RF power detector has a strange scaling.
I am analyzing the calibration data. |
5926
|
Thu Nov 17 14:38:16 2011 |
Zach | Update | RF System | Stochmon? | It turns out that we don't have all the parts I would need to do a full prototype of the precision temperature controller. I am guessing that we won't want to sit around and wait for the parts given the upcoming TAC meeting, so I'll do the next best thing:
- Standard DC temperature readout using an AD590.
- More-or-less complete heater driver
Does anyone have a suggestion for how this thing will be packaged? I.e., should it be in a box or should it be mounted in a rack, etc. In the end, a real board will be printed and stuffed, so this need not be a really professional job in the short term.
Quote: |
Is there an update on Stochmon? Are the signals acquired somewhere already? What's the current deal-io? The new EOM mount should be here later today, and I'm jazzed to start checking how my EOM box helps (hopefully) the amount of RFAM we see.
I'll start making the adapter plate while I wait...
|
|
5951
|
Fri Nov 18 19:07:07 2011 |
Jenne | Update | RF System | Foam house on EOM | [Jenne, Zach, Frank]
Frank helped Zach and I cable up at PT-100 RTD, and make sure it worked with the Newport Model 6000 Laser Diode Controller. We're using this rather than the Newport 3040 Temperature Controller because Dmass says the output of that isn't working. So we're using just the temp control part of the Laser Diode controller.
The back of the controller has a 15-pin D-sub, with the following useful connections. All others were left Not Connected.
1 & 2 (same) - Pin 2 is one side of TEC output (we have it connected to one side of a resistive heater)
3 & 4 (same) - Pin 4 is the other side of the TEC output (connected to the other side of the resistive heater)
7 - connected to one side of PT-100 temp sensor
8 - connected to other side of PT-100 temp sensor
I used aluminum tape to attach the sensor and heater to the 40m's EOM, and we plugged in the controller. It seems to be kind of working. Zach figured out the GPIB output stuff, so we can talk to it remotely.
|
5954
|
Sat Nov 19 00:09:02 2011 |
Zach | Update | RF System | Foam house on EOM |
Quote: |
I used aluminum tape to attach the sensor and heater to the 40m's EOM, and we plugged in the controller. It seems to be kind of working. Zach figured out the GPIB output stuff, so we can talk to it remotely.
|
I stole the Prologix wireless GPIB interface from the SR785 that's down the Y-Arm temporarily. The address is 192.168.113.108. (Incidentally, I think some network settings have been changed since the GPIB stuff was initially configured. All the Prologix boxes have 131.215.X.X written on them, while they are only accessible via the 192.168.X.X addresses. Also, the 40MARS wireless router is only accessible from Martian computers at 192.168.113.226---not 131.215.113.226).
In any case, the Newport 6000 is controllable via telnet. I went through the remote RTD calibration process in the manual, by measuring the exact RTD resistance with an ohmmeter and entering it in. Despite this, when the TEC output is turned on, the heating way overshoots the entered set temperature. This is probably because the controller parameters (gain, etc.) are not set right. We have left it off for the moment.
Here are a couple command examples:
1. Turning on the TEC output
nodus:~>telnet 192.168.113.108 1234
Trying 192.168.113.108...
Connected to 192.168.113.108.
Escape character is '^]'.
TEC:OUT on
TEC:OUT
TEC:OUT?
++read eoi
1
2. Measuring the current temperature
TEC:T?
++read eoi
32.9837
3. Reading and then changing the set temperature
TEC:SET:T?
++read eoi
34.0000
TEC:T 35.0
TEC:SET:T?
++read eoi
35.0000
4. Figuring out that the temperature is unstable and then turning off the TEC (this is important)
TEC:T?
++read eoi
36.2501
TEC:OUT off
TEC:OUT?
++read eoi
0
(The "++read eoi" lines are the commands you give the Prologix to read the controlled device output.)
As I understand, Frank has some code that will pull data in realtime and put it into EPICS. This would be nice. |
5955
|
Sat Nov 19 00:34:36 2011 |
Zach | Update | RF System | why the Newport 6000 isn't working | I just figured out why the Newport 6000 isn't stabilizing the temperature. It is designed to drive a TEC, so that when the temperature is too high, it just applies a negative current. Of course, this doesn't work with a resistive heater; it just keeps heating it up more.
I'm not sure if Frank has actually used this with a restive heater before, but it doesn't appear that you can limit the low-current level or add an offset. |
5976
|
Tue Nov 22 06:12:43 2011 |
Zach | Update | RF System | Prototype temperature controller | Tonight I built a simpler version of what will be the new general-purpose precision temperature controller. This one is built on a breadboard and will be used for RFAM testing at the 40m until a better version is made. Some differences between this version and the final one:
- In the interest of time, this controller senses temperature using a DC wheatstone bridge, instead of the audio-frequency bridge of the final controller.
- I eschewed the more complicated transistor current source in favor of a simple current buffer. In effect, using a constant-current source is not absolutely necessary, since we are not interested in constant current but rather a constant system temperature. In this sense, it doesn't matter if we have a transistor current source or a transistor voltage source or a current-buffered op amp voltage source; the loop will simply drive the heater with the proper current to keep the error signal nulled.
So, how it works:
- The DC bridge drive voltage is supplied by a voltage-divided and buffered AD587 (low-noise 10-V reference).
- The reference resistors are just 1% metal film leaded resistors, but I have put some effort into making them quiet:
- Each resistor's body is wrapped in Al tape, and then all the resistors are taped together using Al tape, as well. This is to strongly couple them to each other thermally.
- All the reference resistors are embedded in some foam I found in the Bridge sub-B hallway. It's nothing fancy, but it keeps large advection currents from causing thermal drifts.
- The sensing element is a PT100 100-ohm RTD. Tempco is ~0.0037 1/K
- The bridge differential voltage is read out by an AD620 instrumentation amplifier with G = 100
- The AD620 output is fed directly to an OP27 with G = 0-20
- This is fed to an LF356 (FET-input op amp, to reduce the effects of bias current when the integrator is on) with a single pole at 0.1 Hz, switchable via jumper to DC for true integration
- This is summed with an offset via an OP27 summer (the offset determines the heater current with no signal---half the maximum current of ~120 mA is optimal)
- The summer output is buffered with a BUF634, which can provide well over the maximum current we can push through our heater, and the BUF634 directly drives the heater
- Between the BUF634 and the heater is a back-biased diode to ground. This is to prevent the current from going negative when the error signal is well below zero.
I have tested the circuit using a spare resistive heater and a potentiometer to simulate the RTD. First I tested the sensing and drive circuits separately, then I connected the sensor output to the drive input and modulated the potentiometer resistance while monitoring the current. The circuit behaved as expected.
When I got to the 40m, it struck me that the resistance I had chosen (115 ohms) corresponded to 40 C, which I realized might be above what we could reach with the current we can provide. I used the Newport 6000 via telnet to drive the heater at several current values and see what the resistance became. I found that with I = Imax/2 ~ 0.6, the resistance was around 113 ohms (it was ~111 at room temp). So, I switched the reference resistor in the leg above the PT100 from 115 -> 113.
I then plugged everything in while monitoring the heater current and AD620 output (error signal), and it seemed not to do anything. I was tired so I figured I'd leave it for tomorrow.
Here is a sketch of the schematic, as well as some pictures:
  

|
5984
|
Wed Nov 23 00:30:14 2011 |
Zach | Update | RF System | EOM temperature controller trials | [Jenne, Zach]
We did some testing of the prototype temperature controller. When I left it late last night, it was not working in conjunction with the real heater and PT100 mounted to the EOM, but had been tested using simulated loads (a spare heater and a potentiometer for the RTD).
We measured each of the reference resistors carefully, as I should have done in the first place since they are only 1% tolerance (I am using 100-ohm ones in series with ~15-ohm ones, so they have a variation of +/- an ohm or so, which is consequential). We calculated the estimated zero-signal resistance of the RTD, then used a trimpot to verify that the AD620 output behaved as expected. We realized that I didn't tie the 620's reference to ground, so the output was floating around by a lot. Once we did that, the readout was still not working properly, but eventually magic happened and we got an appropriate signal. I did find that there was a discrepancy between the estimated zero-signal resistance and that measured across the trimpot with the readout nulled---this may be caused by a small offset in the 620, but is not important so long as the output still scales properly.
Before trying it out again on the real McCoy, I tested the whole, closed-loop circuit with the spare EOM on Jenne's desk. The temperature oscillated at first, but a reduction of gain at the input stage of the driver allowed it to stabilize. The temperature of the EOM (sitting on the electronics bench) was kept constant with a control current that varied from ~40 - 70 mA, depending on how many people were around it, etc. This is pretty much perfect for the quiescent level, but that means that we might have to increase the baseline operating resistance of the PT100 (by changing the reference resistors) once it is sitting in a hot foam box. Otherwise, we will have no gain on the cooling side. I tested the circuit response by cupping my hands over the EOM to increase the temperature and ensuring that the current dropped so as to null the error signal. It worked pretty well, with a thermally-limited bandwidth of I would estimate around 0.1 Hz.
I went to try it out on the PSL table, but again it didn't work. It turned out that this time I had broken one of the soldered connections from the broken-out D-sub cable to the (tiny) wires going to the PT100, so there was no temperature signal. I resoldered it, but I forgot that there is a thin insulating layer on the wire, so no connection was made. Frank tutored Jenne on how to properly strip these wires without damaging the core, but alas I didn't pay attention.
The RTD/heater/D-sub package lies in wait on Jenne's desk, where I have left an apologetic note. Once it is fixed, we should be able to finally hook it up for realz. |
6022
|
Mon Nov 28 14:27:35 2011 |
Jenne | Update | RF System | EOM temp driver | Here is 5 days of trend of the EOM temp sensor and the heater driver monitor. Unfortunately, it looks like we're regularly railing the heater. Not so awesome. |
Attachment 1: EOM_temp_driver_3days.png
|
|
6023
|
Mon Nov 28 14:40:43 2011 |
Koji | Update | RF System | EOM temp driver |
Quote: |
Here is 5 days of trend of the EOM temp sensor and the heater driver monitor. Unfortunately, it looks like we're regularly railing the heater. Not so awesome.
|
Can you zoom the temp mon? (V= -0.1 ~ +0.1)
The crystal was too cold and I tried to heat the PSL table by the lighting. But it seemed in vain. |
6025
|
Mon Nov 28 15:43:36 2011 |
steve | Update | RF System | EOM temp zoomed |
Quote: |
Quote: |
Here is 5 days of trend of the EOM temp sensor and the heater driver monitor. Unfortunately, it looks like we're regularly railing the heater. Not so awesome.
|
Can you zoom the temp mon? (V= -0.1 ~ +0.1)
The crystal was too cold and I tried to heat the PSL table by the lighting. But it seemed in vain.
|
It is not working |
Attachment 1: eomtempmon.png
|
|
6032
|
Tue Nov 29 02:09:15 2011 |
Zach | Update | RF System | EOM temp stabilization fixed | I inspected the temperature stabilization circuit today to see why it wasn't working. It didn't make sense that it just kept railing the heater even though the error signal was negative (which should turn the heater current OFF).
It turns out that the LF356 (FET-input op amp) that serves as the filter stage for the heater driver was broken---I measured a full, railed positive output even though the input was negative. We didn't have any more LF356s, so I replaced it with an OPA604 (Burr-Brown FET-input), and all seemed to work fine.
Since we were having too much digitization noise, I also added a temperature monitor buffer using a non-inverting OP27 circuit with G=99. This makes the overall calibration ~7.6 V/K into the ADC.
Below is a time series showing that it is working. The circuit was turned on near the beginning, and you can see that the heater is railed at +10V until shortly after the error signal goes negative, at which point it adjusts and ultimately approaches a steady-state value of ~7.8V.

I have no figures to demonstrate this, but it seems that even with this 100x increase in monitor gain, the error signal is still below the ADC noise level. This could be because the ambient temperature fluctuations are just that small on timescales of less than a few hours. I'm not sure if we really need to be able to see the temperature noise level above a few mHz, but if we do we will have to find some way to increase our dynamic readout range.
Also, Koji told me where he stashed the nice protoboards, so I will get onto transferring this circuit onto one ASAP. Since it is working now, I think I'll leave it until after the TAC. |
6035
|
Tue Nov 29 14:22:03 2011 |
Zach | Update | RF System | EOM temp stabilization performance | I left the EOM stabilization running overnight, so we can finally see how the EOM temperature stabilization does over long periods of time.
Here are both long-term (~13-hr) and short-term (1-hr) trends of the EOM temperature and the heater drive level. From the long trend you can see that the heater departed the steady value of ~7.8V that I observed last night to accommodate the diurnal heating of the lab in the morning---the temperature was held near zero offset.
From the short-term trend, there are 2 things to notice:
- We are still very close to the digitization noise level for both signals. This is bad, because we want to look at the residual noise level, etc.
- There appears to be some strange sort of disturbance of f~0.01-0.02 Hz. I'm not sure what causes the strange shape

Finally, here is a trend over the last ~24 hours of the EOM temperature, heater drive level, and the 11- and 55-MHz Stochmon signals. I believe that the abrupt shelves noticeable on the Stochmon trends are when c1sus was turned on and shut down, respectively (I'm not sure why that causes the signals to die, but the times seem right, and nothing obvious happens to the EOM temp stabilization signals at either time). The controller was turned on at ~8:40 UTC, and you can see that the Stochmon signals quiet down a lot right at that time. There is some residual drift (common-mode to both RF frequencies), which is most likely caused by a drift in some other parameter (e.g. laser frequency or power).

I took some relatively inconclusive power spectra and coherence measurements, but I'd rather wait until we have an uncontrolled data stretch with which to compare. I think what we should do now is disconnect the controller and then let it sit for a while.
|
6036
|
Tue Nov 29 15:25:29 2011 |
steve | Update | RF System | EOM temp stabilization performance | It is not obvious what is working.
|
Attachment 1: 2days.png
|
|
6040
|
Tue Nov 29 18:17:27 2011 |
Zach | Update | RF System | EOM temp stabilization performance |
Quote:
|
It is not obvious what is working.
|
It should be. As I mentioned, you can only trust the Stochmon signals between 0840 and 1130 UTC; before this time, the temperature controller was not connected, and after this time, c1sus is shut down and the MC is not locked, as you can see in your DV plot.
Within this time frame, the Stochmon signals are relatively stabilized (though there is some residual common-mode-ish drift since we are not using RFAM as the error signal---i.e., other things like laser power and frequency can mix in). Also, anytime after 0840, the controller signals behave as they should (these are unaffected by the status of c1sus):
- The EOM temperature signal (error signal) is stabilized to a value very near zero
- The heater drive signal (control signal) moves around in such a way as to null the error signal, and you can confirm that it looks roughly like the opposite of the FSS_RMTEMP signal, as it should.
I am concerned with the other issues that I mentioned in my previous post, namely:
- Error signal dominated by digitization noise above some low frequency despite 100x amplification
- Strange ~0.01-Hz level disturbances in error signal.
|
6043
|
Tue Nov 29 19:08:53 2011 |
Zach | Update | RF System | EOM heater disconnected | I disconnected the heater at ~2:20 UTC, leaving the sensor circuit operational. Don't be fooled by the apparent railing of the heater in the monitor trace below---the heater has been physically disconnected, so there is no current flowing even though the servo is railed (since the error signal is huge with the loop open).
Kiwamu and I also restarted c1sus and locked the MC so that we can get some uncontrolled Stochmon data. I think he is planning to reconnect the heater some hours from now so that we can get yet another controlled data stretch (since the first one was cut short by c1sus's going down).

|
6044
|
Tue Nov 29 22:10:18 2011 |
kiwamu | Update | RF System | RFAM fluctuation reduced |
Quote from #6035 |
I left the EOM stabilization running overnight, so we can finally see how the EOM temperature stabilization does over long periods of time.
The controller was turned on at ~8:40 UTC, and you can see that the Stochmon signals quiet down a lot right at that time.
|
Indeed the fluctuation of the RFAM became quieter with the temperature control ON. 
However the absolute value of the RFAMs stayed at relatively high value.
I guess we should be able to set the right temperature setpoint such that the absolute value of the RFAM is smaller.
Here is the calibrated RFAM data (for 5 hours around the time when Zach activated the temperature control last night):

|
6047
|
Tue Nov 29 23:03:34 2011 |
Zach | Update | RF System | RFAM fluctuation reduced | I was hesitant to claim that this is definitely true without the control data we were taking after the heater was turned off today. This is because before I replaced the malfunctioning op amp last night, the heater was actually ON and injecting temperature noise into the system that would not be there with it off. I think the best idea is to compare the data from today (heater on vs. heater off, but with functioning circuit).
Quote: |
Indeed the fluctuation of the RFAM became quieter with the temperature control ON. 
|
|
6050
|
Wed Nov 30 03:01:55 2011 |
kiwamu | Update | RF System | RFAM fluctuation reduced | Okay I have turned ON the temperature control at 2:40 AM and will leave it ON for a while.
Quote from #6047 |
I was hesitant to claim that this is definitely true without the control data we were taking after the heater was turned off today. This is because before I replaced the malfunctioning op amp last night, the heater was actually ON and injecting temperature noise into the system that would not be there with it off. I think the best idea is to compare the data from today (heater on vs. heater off, but with functioning circuit).
|
|
6053
|
Wed Nov 30 13:52:09 2011 |
Zach | Update | RF System | EOM temp stabilization ineffectual | This recent off/on run proved what I was afraid of: the temperature stabilization setup appears to do nothing except very near DC. The plot that Kiwamu posted is misleading because the "uncontrolled" data stretch at the beginning actually had the heater injecting random noise (since the circuit was broken). Below are some plots (sorry in advance for their crappiness---the plot tools wouldn't let me print to file for some reason):
Time series of the temp monitor, the heater monitor, and the 11- and 55-MHz RFAM monitors. The heater was disconnected at ~2:20 UTC, and the temperature is seen to equalize to the surroundings (note that the TEMP_MON is inverted, so positive change means decreasing temperature). The heater was reconnected by Kiwamu around 10:40 UTC, and you can see the temperature being driven back to the zero point by the loop. Note that the temperature was still decreasing at a fair rate when the heater is re-engaged---this could mean that we really need to take longer samples.

Spectra and coherence of the 11- and 55-MHz RFAM monitors before and after the control was re-engaged. It appears that the 11-MHz signal is unaffected while the 55-MHz signal actually gets worse. This also seems evident from the noisiness in the time series for that signal above (top right). Bad, bad, bad.

Spectrum of the EOM temperature signal before and after control was re-engaged. There seems to be no change whatsoever. Of course, as mentioned before, this signal seems to be close to the digitization noise level as seen in DV. I am not sure what the ADC noise looks like at these low frequencies. In case someone knows, the magnitude of this signal in counts is ~0.1 ct/rHz at 10 mHz; is this too low? Another thing to note is that the noise level in K is pretty low! I would be surprised if the RTD can really see 10 uK/rHz at and below 10 mHz.

I need to try and increase the gain of the servo to see if I can get it much higher without it becoming unstable. |
6054
|
Wed Nov 30 14:12:53 2011 |
Jenne | Update | RF System | New EOM mount almost ready | The new EOM adapter plate and riser just got back from the shop. I just had Mike do the milling, and I'll drill and tap them tomorrow after the TAC. Then we can remount the EOM to see if stiffening the mount helps at all. |
6055
|
Wed Nov 30 22:09:20 2011 |
Zach | Update | RF System | some final EOM stabilization efforts | First, things that were done:
- I was troubled by the odd-looking noise in the EOM temperature signal, so I investigated the circuit with a probe and found that there was quite a bit of line pickup, which I traced to the wires going to and from the RTD (if I placed a dummy resistor directly on the board, it went down markedly).
- I put a 3-Hz RC LPF between the AD620 and the driver input buffer, which reduced the line noise significantly
- The error signal looks much cleaner and there are no longer strong peaks in the error spectrum at ~1+ Hz and harmonics
- I had tried earlier to increase the gain of the servo at the driver input stage. It seemed to stay stable. Since I knew the error signal with the loop closed was at the level of the ADC noise, I decided to push my luck with increasing the servo gain and juice up the AD620 gain from 100 to 990.
- The servo stayed stable and the error signal level is now manageable.
Things that I noticed:
- With the latest increase in gain, I measured that the error signal was suppressed with the loop closed (the suppression is below ~0.1 Hz, and the reason that the high-frequency level is different is because it has been amplified above the ADC noise by the time of the second trace).

- Despite the above, the Stochmon signals remained unchanged no matter what I did. I noticed that the Stochmon signals, too, were fluctuating basically at bit-level. I terminated the 11-MHz signal and compared it to the normal level---it is not exactly the same, but only a factor of 2-3 lower, which is not great. Of course, the RMS detector is logarithmic, but I think we still want the dark noise to be at least an order of magnitude lower here.
- I tried to amplify the signal with an SR560, but since the DC level is supposed to be ~1-2 V, I could only get about 2x gain---not enough.

Conclusion
I think there are two things that could be happening here, given the above information:
- We are limited by the noise of the temperature sensing circuit, which would explain why the in-loop error signal is suppressed while the RAM levels appear not to be. This should be easy enough to test (though there's not enough time right now) with an out-of-loop sensor.
- The RAM is not dominated by temperature noise here. With the loop open, one would expect to see coherence between the RAM signal and the temperature sensor, if indeed one was the cause of the other. Instead, we see that---while the 11- and 55-MHz signals ARE pretty coherent with each other---there is no appreciable coherence between the temperature and the Stochmon signal.
|
6056
|
Thu Dec 1 01:24:56 2011 |
Jenne | Update | RF System | EOM temp stabilization at PSL lab | [Frank, Jenne]
Activities in a far, far away land called PSL lab...

We are looking at the RFAM from the detuned ACAV refl pd in the red trace. Red trace is the demodulated RFAM output. RCAV was locked, so on a ~min time scale the freq drift follows, so we stay detuned.
Heater and temp sensor are taped to EOM, no foam box.
Around when the red trace starts, we turn on the heater to stabilize the temp. After a while we reach the set point (no longer railing the heater), and start seeing temp stabilization. The RFAM fluctuations clearly go down. Neato.
No calibrations, no RIN, no nothing. Get over it.
Green trace is the DC level of a different PD, which should also be sensitive to RFAM.
This is using a fancy-pants temp controller chip that Frank found. It works, so that's handy. |
6059
|
Thu Dec 1 12:27:51 2011 |
Zach | Metaphysics | RF System | RAM diagnosis/suppression plan? | It seems like there is some confusion---or disagreement---amongst the lab about how to proceed with the RAM work (as Rana mentioned at the TAC meeting, we will henceforth refer to it only as "RAM" and never as "RFAM"; those who refuse to follow this protocol will be taken out back and shot).
I would like to provide a rough outline and then request that people reply with comments, so that we can get a collective picture of how this should work. I have divided this into two sections: 1) Methodology, which is concerned with the overall goal of the testing and the procedure for meeting them, and 2) General Issues, which are broadly important regardless of the chosen methodology.
1. Methodology
There are two broad goals:
- Characterization of extant RAM
- Measuring the RAM levels existing in an aLIGO-type interferometer without any suppression systems
- Modeling to estimate the effect on IFO control and corroboration with measurements where possible
- DC RAM levels contributing offsets to IFO operating point
- Quasi-DC RAM levels affecting long term detector tuning (e.g., sensing matrix, MICH -> DARM feedforward, etc.)
- Audio-frequency RAM contributing noise directly via error point modulation
- Modeling to scale/adapt results from 40m -> aLIGO
- Mitigation
- Developing and assessing systems for suppressing RAM
- Passive: thermal shielding and isolation
- Active: EOM temperature control
- Simple temperature stabilization
- RAM error signal
The question is: which is our goal? The first, the second, or both? If both, what priority is given to which and can/should they be done in parallel? Also, task distribution.
2. General Issues
These are loosely related, so they are in random order:
- Sensing
- Temperature
- What is the priority/urgency of a precision AC-bridge-readout temperature sensor?
- If priority/urgency is low, what is the priority/urgency of upgrading breadboard controller to protoboard version? The common answer will be "make the protoboard version now", but if the urgency of the final AC sensing is high, it may make sense to focus on finalizing that design (after all, other experiments are waiting on a precision temperature controller, and it is not cost-effective to make many temporary controllers as I have done for the 40m).
- Sensor noise issues
- What is the sensor-noise-limited temperature stabilization level?
- What is our willingness to tolerate the thermal low-passing of the EOM can itself (i.e., what is our sensitivity to gradients)?
- To answer the above questions, we need to perform stabilization tests with several sensors on the same can, with some in loop (averaged) and some out of loop.
- If we determine that gradients are a problem, we may need to:
- Design a casing for outside the EOM (inside the foam box) to make the heating uniform, or
- We may be able to get away with a more customized heater (instead of heating the can from one side as we do now).
- Optical RAM
- Stochmon is a nice diagnostic tool, but do we want something better? In particular, we want to have linear signals about a zero-DC-RAM point, which requires phase
- Where will this sensor be located?
- What kind of PD will it be? Broadband? Multi-resonant?
- What sort of electronics will we need? If we are going to use this as an error signal for controlling the EOM temperature, it is just as important as any other IFO readout, since it may couple into all of them.
- RF pickup is a BIG ISSUE HERE
- How will the demodulation phases be selected? It should be possible to take TF measurements in certain misaligned (i.e., non-resonant) conditions and adjust the relative phase between the RAM readouts and standard IFO RF readouts such that they are in phase, but this will require some thinking.
- Lots more, I'm sure
- Control
- Method (overlaps some with methodology portion)
- What is better, simple temperature stabilization or RAM feeback? (More likely, "how much better is RAM feedback?")
- If RAM feedback is difficult or impossible to implement effectively (see below), is temperature stabilization good enough?
- Regime
- Depending on extant RAM levels and on achievable sensing noise, it will be unwise and/or unnecessary to have a RAM control bandwidth above some relatively low frequency (~sub Hz)
- Gain where RAM suppression is not needed only injects noise into the system
- This cutoff frequency is largely determined by the thermal response of the system, but additional filtering will likely be necessary to reduce higher-frequency noise coupling (e.g., nonlinear downconversion of high-frequency signals into heater dissipation, etc.)
- Efficacy
- If we do RAM feedback, which signal (i.e. which frequency and quadrature) do we minimize?
- Do we achieve large common-mode reduction across all RF signals, or is there some differential component?
- In particular, do we make some or all other control signals noisier by stabilizing/minimizing RAM in one channel?
- If the answer is yes, can we derive an effective control signal from a linear combination of some or all individual RAM signals?
There are probably many other issues I have neglected, so please comment on this rough draft as you see fit! |
6069
|
Mon Dec 5 09:46:21 2011 |
Zach | Metaphysics | RF System | RAM diagnosis/suppression plan? | Since no one has made any comments, I will assume that everyone is either 100% satisfied with the outline or they have no interest in the project. Under this assumption, I will make decisions on my own and begin planning the individual steps in more detail.
In particular, I will assume that our goal comprises BOTH characterization of RAM levels and mitigation, and I will try to find the best way that both can be achieved as simultaneously as possible. |
6073
|
Mon Dec 5 19:38:38 2011 |
Jenne | Update | RF System | EOM mount getting closer.... | I have drilled all the holes necessary, and have tapped all but 4 of the holes for the new EOM mount. The adapter plate is finished and ready to go (including a 10-min iso sonic bath). The riser that goes between the table and the 9082 mount is drilled but not yet tapped. |
6077
|
Tue Dec 6 21:37:08 2011 |
Jenne | Update | RF System | New EOM mount in place | EOM is remounted on the fancy-pants new mount that I crafted. EOM is also aligned. 2 green mirrors (the first ones to see the beams coming onto the PSL table from the arm transmissions) had to be moved so I could fit the mount in, since the new mount is bigger than the old one. I put them back, and approximately realigned them, but didn't do any fine alignment. This must be done before looking at beatnotes again.
After playing with the EOM, the MC was flashing on higher order modes. The PSL beam has been realigned to make the MC lock on TEM00, and Suresh helped me center on the WFS and MC2T.
Things look okay for now. Next step: Kiwamu needs to find his happy mode cleaner place, and we'll realign the PSL beam to the MC. The PSL-MC axes were mismatched pretty badly according to Suresh anyway, so this had to be done no matter what. |
6079
|
Wed Dec 7 00:48:58 2011 |
kiwamu | Update | RF System | Realigned incindent pointing to MC | Actually it was already in a good place.
I just realigned the zig-zag mirrors on the PLS table to bring the entire beam axis a little bit upward.
The WFS servo still seems fine. The input pzt mirrors are still within their range.
|
Next step: Kiwamu needs to find his happy mode cleaner place, and we'll realign the PSL beam to the MC. The PSL-MC axes were mismatched pretty badly according to Suresh anyway, so this had to be done no matter what.
|
|
6082
|
Wed Dec 7 18:47:36 2011 |
Jenne | Update | RF System | RAM Mon is now being demodulated | There were 2 open outputs on the splitter in the RAMmon (formerly known as Stochmon) box underneath the BS oplev table. The input to the splitter comes from the Thorlabs PD that we're using as our RAM monitoring PD. 2 of the outputs go to the RMS detection of 11 and 55 MHz. Now the other 2 (previously terminated) outputs go over to the LSC rack via SMA cable. The signal on both channels is ~200mV pk-pk, so -10dBm. One is plugged into the AS11 demod board (which didn't have a PD input yet), and the other goes to POP55's demod board, so POP55 is not what you think it is for now.
Koji is working on checking out the Rich box, which has 4 demodulators, which we will use eventually. Right now we're just using the already-plugged-in demod boards so we can start looking at some trends of RAM. We're going to need to find some channels when we're ready for the switchover.
Zach is nearing completion of the mini-update to the temp sensing system. Once we have the new more sensitive temp sensor in place, we can have a look-see at the similarities between EOM temperature and RAM levels. |
6086
|
Thu Dec 8 00:45:13 2011 |
Koji | Update | RF System | 4ch demod is ready | I have tested the left 2ch of 4ch demod board.
The left most is for 11MHz, and the next one is for the 55MHz. |
6087
|
Thu Dec 8 01:26:31 2011 |
Zach | Update | RF System | EOM temp sensor modified | I have modified the EOM temperature sensor circuit for the temperature vs. RAM long-term measurements. The only real change is that the sensor is a 100-kOhm thermistor, instead of a 100-Ohm RTD. These semiconductor thermistors (DigiKey P/N 317-1377-ND) are highly nonlinear and can be much more responsive than RTDs, but this difference is much more noticeable at low temperatures.
Frank had told me that the fractional response of the thermistors was so much higher that I could scale the bridge drive current down by the same factor as the resistance was increasing (i.e., 1 mA -> 1 uA, commensurate with 100 ohms -> 100k) and still see a marked improvement. It turns out that at room temperature for this particular sensor the gain enhancement would only be about ~10x, so I only reduced the drive current to ~10 uA, by INCREASING the drive voltage from ~0.1 V -> 1 V, improving the enhancement to ~100x.
Below is a plot of the real nonlinear response of the thermistor, along with a linear approximation at 298.15 K, which gives a coefficient of ~ -4.67 kOhms/K. The differential bridge output voltage response for the new resistance and current is ~7.5 uV/Ohm 2.5 uV/Ohm, bringing the total temperature response before amplification to ~35 mV/K 11.6 mV/K. Looking at a trend of the FSS_RMTEMP channel over a month, we saw that the maximum PSL table temperature fluctuations were ~2 Kpp, so we aimed the maximize resolution by matching +/- 2 K with +/-10 V at the ADC. This was done by using a gain of ~300 in the AD620 that amplifies the differential bridge output. We found that a gain of ~300 put it pretty close, so the grand total calibration ~ 10.5 V/K 3.5 V/K.
Edit (ZK): I screwed up with calculating the bridge response by a factor of three somehow, so I have stricken and restated the calibrations above

I took a look at the recently acquired temperature data alongside the RAMmon 11 and 55 signals, and it appears that we're seeing the same sort of fringing effects we usually see, with oscillatory RAM levels for a monotonic change in EOM temperature.The odd bit towards the end is caused by the MC losing lock.
It is going to be very interesting to find out what causes this fringing.

|
6088
|
Thu Dec 8 11:59:53 2011 |
Zach | Update | RF System | fringing indeed | Here is a trend of 11 & 55 I&Q, along with the EOM temperature and PSL RMTEMP signals. You can see that there is definitely some fringe-like behavior for monotonic changes in temperature. This is consistent with what I have seen on the gyro table in the past.
Some other notes:
- The EOM temperature (or at least the sensor temperature) seems to track RMTEMP almost exactly when there is no foam box on the EOM. I have verified that the max-min swing here is the same for both signals (~0.77 K).
- Something crazy appears to happen at ~10:15, and all the RAM signals get much noisier. Does anyone know what happened at this time (2:15am local)?
We ought to get to the bottom of the fringing. The CTE of LiNbO3 is ~2 ppm/K, so given that the wavelength is on the order of 0.5 K, this is probably not caused by the etalon effect (2ppm/K * 0.5K * ~1cm << 1064nm).

|
6090
|
Thu Dec 8 16:54:05 2011 |
Jenne | Update | RF System | Installation of new demod box | So far:
* New demod box has been placed in the LSC rack.
* An extra set of +\- 24V has been prepared at the terminal block where all the Crates get their power on the LSC rack. The grounds were all connected up, but the hot wires weren't. So there were extra spots available, but none that were pre-wired with my voltages.
* To do this I turned off all the power supplies in the short rack, since I decided to be a live chicken rather than a dead duck. After hooking up the new terminal block slots, I turned on the power supplies.
* Make a power cable to go from the terminal block to the box
Still to do:
* Connect the spare 55MHz LO and the POP (or POX or POY) unused 11MHz LO to the back of the box
* Move the PD inputs to the new demod box rather than the borrowed AS11 and POP55 boards
* Plug the I & Q outs for each freq into some spare ADC channels - must first make sure we have 4 open channels.
* See if it works. |
6092
|
Thu Dec 8 22:44:55 2011 |
Koji | Update | RF System | 4ch demod test result | 1) Linearity Test
LO input level was +10dBm. The LO freq was 11MHz and 55MHz for CH1 and CH2 respectively.
The IF frequency was fixed at 10kHz.
The amplitude of the RF input was swept from -50dBm to +15dBm.
Basically I and Q output of CH1 and CH2 was quite linear in this amplitude range.
2) Freqency Response
RF input was fixed at -20dBm and the IF frequency was swept from 1kHz to 1MHz.
The response was flat upto 100kHz, and have sensitivity upto 300kHz.
3) Output noise
Noise floor of the output is ~20nV/rtHz. All of the channels behave in the same way.
1/f start from 100Hz. |
Attachment 1: RF_DEMOD_TEST_111208.pdf
|
|
|