ID |
Date |
Author |
Type |
Category |
Subject |
3085
|
Fri Jun 18 13:42:52 2010 |
Koji | HowTo | General | Update your work |
All SURFs (and all others as always) are supposed to post the update of your status on the elog.
In fact, I already heard that Sharmila had been working on the serial connection to TC-200 and made some results. All of us like to hear the story. |
6956
|
Wed Jul 11 09:48:24 2012 |
Liz | Summary | Computer Scripts / Programs | Update/daily summary testing |
I have been working on configuration of the Daily Summary webpages and have been attempting to create a "PSL health" page. This page will display the PMC power, the temperature on the PSL table and the PSL table microphone levels. Thus far, I have managed to make the extra PSL tab and configure the graph of the interior temperature, using channel C1:PSL-FSS_RMTEMP.
I have been attempting to make a spectrogram for one of the PMC channels, but there is an issue with the spectrogram setup, as Duncan Macleod noted in ELOG 6686:
"At the moment a package version issue means the spectrogram doesn't work, but the spectrum should. At the time of writing, to use the spectrum simple add 'plot-dataplot2'."
Because of this issue, I have also been trying to make the spectrogram plots work. Thus far, I have fixed the issue with one of the spectrogram plots, but there are several problems with the other four that I need to address. I have also been looking at the microphone channels and trying to make the plot for them work. I checked which microphone was on the PSL table and plotted it in matplotlib to make sure it was working. However, when I tried to incorporate it into the daily summary pages, the script stops at that point! It might simply be taking an excessively long time, but I have to figure out why this is the case.
(I am using channel C1:PEM-MIC_6_IN1_DQ, if this is blatantly wrong, please let me know!!)
The main point of this ELOG is that I have working test-daily summary pages online! They can be found here:
https://nodus.ligo.caltech.edu:30889/40m-summary-test/archive_daily/20120710/
Also, if anyone has more requests for what they would like to see on the finalized summary pages site, please respond to this post or email me at: endavison@umail.ucsb.edu |
5265
|
Thu Aug 18 22:24:08 2011 |
jamie | Omnistructure | VIDEO | Updated 'videoswitch' script |
I have updated the 'videoswitch' program that controls the video MUX. It now includes the ability to query the video mux for the channel mapping:
controls@pianosa:~ 0$ /opt/rtcds/caltech/c1/scripts/general/videoswitch -h
Usage:
videoswitch [options] [OUT] List current output/input mapping [for OUT]
videoswitch [options] OUT IN Set output OUT to be input IN
Options:
-h, --help show this help message and exit
-i, --inputs List input channels and exit
-o, --outputs List output channels and exit
-l, --list List all input and output channels and exit
-H HOST, --host=HOST IP address/Host name
controls@pianosa:~ 0$
|
1205
|
Mon Dec 29 18:01:07 2008 |
Aidan | Update | Auxiliary locking | Updated 40m Upgrade Document T080074-00-R |
Added a paragraph to the 40m Upgrade document describing the fiber stabilization and frequency doubling proposed for auxiliary locking.
Also added a complete diagram of the fiber stabilization and a draft sketch of the frequency doubling.
Uploaded to https://nodus.ligo.caltech.edu:30889/svn/trunk/docs/upgrade08/ via svn. |
11115
|
Sat Mar 7 19:23:27 2015 |
Jenne | Update | LSC | Updated ALSwatch script |
Last report on model change / screen work from yesterday.
The ALSwatch script has always been just looking at the EPICS output of the CARM and DARM filter banks, and if it saw a single saturation, it would run the down script. This was non-ideal because (a) the EPICS channels aren't the real signals, and (b) sometimes we'll hit the rails briefly and that's okay - we want to shut things down only when we're constantly saturating.
It turns out that there was a pre-existing saturation monitor part in CDS_PARTS, which I have used. There is one each looking at the output of the CARM and DARM filter banks. The threshold for what saturation means is set as an epics input. The part outputs a running count (number of saturations since the last time it was not saturated, resets each time it goes non-saturating) and a total number since the last reset (also an epics input).
(To be continued... still writing) |
15738
|
Fri Dec 18 22:59:12 2020 |
Jon | Configuration | CDS | Updated CDS upgrade plan |
Attached is the layout for the "intermediate" CDS upgrade option, as was discussed on Wednesday. Under this plan:
-
Existing FEs stay where they are (they are not moved to a single rack)
-
Dolphin IPC remains PCIe Gen 1
-
RFM network is entirely replaced with Dolphin IPC
Please send me any omissions or corrections to the layout. |
Attachment 1: CDS_2020_Dec.pdf
|
|
Attachment 2: CDS_2020_Dec.graffle
|
15742
|
Mon Dec 21 09:28:50 2020 |
Jamie | Configuration | CDS | Updated CDS upgrade plan |
Quote: |
Attached is the layout for the "intermediate" CDS upgrade option, as was discussed on Wednesday. Under this plan:
-
Existing FEs stay where they are (they are not moved to a single rack)
-
Dolphin IPC remains PCIe Gen 1
-
RFM network is entirely replaced with Dolphin IPC
Please send me any omissions or corrections to the layout.
|
I just want to point out that if you move all the FEs to the same rack they can all be connected to the Dolphin switch via copper, and you would only have to string a single fiber to every IO rack, rather than the multiple now (for network, dolphin, timing, etc.). |
15746
|
Wed Dec 23 23:06:45 2020 |
gautam | Configuration | CDS | Updated CDS upgrade plan |
- The diagram should clearly show the host machines and the expansion chassis and the interconnects between them.
- We no longer have any Gentoo bootserver or diskless FEs.
- The "c1lsc" host is in 1X4 not 1Y3.
- The connection between c1lsc and Dolphin switch is copper not fiber. I don't know how many Gbps it is. But if the switch is 10 Gbps, are they really selling interface cables that have lower speed? The datasheet says 10 Gbps.
- The control room workstations - Debian10 (rossa) is the way forward I believe. it is true pianosa remains SL7 (and we should continue to keep it so until all other machines have been upgraded and tested on Debian 10).
- There is no "IOO/OAF". The host is called "c1ioo".
- The interconnect between Dolphin switch and c1ioo host is via fiber not copper.
- It'd be good to have an accurate diagram of the current situation as well (with the RFM network).
- I'm not sure if the 1Y1 rack can accommodate 2 FEs and 2 expansion chassis. Maybe if we clear everything else there out...
- There are 2 "2GB/s" Copper traces. I think the legend should make clear what's going on - i.e. which cables are ethernet (Cat 6? Cat 5? What's the speed limitation? The cable? Or the switch?), which are PCIe cables etc etc.
I don't have omnigraffle - what about uploading the source doc in a format that the excellent (and free) draw.io can handle? I think we can do a much better job of making this diagram reflect reality. There should also be a corresponding diagram for the Acromag system (but that doesn't have to be tied to this task). Megatron (scripts machine) and nodus should be added to that diagram as well.
Please send me any omissions or corrections to the layout.
|
|
15771
|
Tue Jan 19 14:05:25 2021 |
Jon | Configuration | CDS | Updated CDS upgrade plan |
I've produced updated diagrams of the CDS layout, taking the comments in 15476 into account. I've also converted the 40m's diagrams from Omnigraffle ($150/license) to the free, cloud-based platform draw.io. I had never heard of draw.io, but I found that it has most all the same functionality. It also integrates nicely with Google Drive.
Attachment 1: The planned CDS upgrade (2 new FEs, fully replace RFM network with Gen 1 Dolphin IPC)
Attachment 2: The current 40m CDS topology
The most up-to-date diagrams are hosted at the following links:
Please send me any further corrections or omissions. Anyone logged in with LIGO.ORG credentials can also directly edit the diagrams. |
Attachment 1: 40m_CDS_Network_-_Planned.pdf
|
|
Attachment 2: 40m_CDS_Network_-_Current.pdf
|
|
15772
|
Tue Jan 19 15:43:24 2021 |
gautam | Configuration | CDS | Updated CDS upgrade plan |
Not sure if 1Y1 can accommodate both c1sus2 and c1bhd as well as the various electronics chassis that will have to be installed. There may need to be some distribution between 1Y1 and 1Y3. Does Koji's new wiring also specify which racks hold which chassis?
Some minor improvements to the diagram:
- The GPS receiver in 1X7 should be added. All the timing in the lab is synced to the 1pps from this.
- We should add hyperlinks to the various parts datasheets (e.g. Dolphin switch, RFM switch, etc etc) so that the diagram will be truly informative and self-contained.
- Megatron and nodus, but especially chiara (NFS server), should be added to the diagram.
|
3962
|
Mon Nov 22 12:00:18 2010 |
josephb | Update | CDS | Updated Computer Restart Procedures for FB |
I've updated the Computer Restart Procedures page in the wiki with the latest fb restart procedure.
To just restart just the daqd (frame builder) process, do:
1) telnet fb 8088
2) shutdown
The init process will take care of the rest and restart daqd automatically.
Background:
Plan:
- Check the wiring after SOS Coil Driver Module and circuit around SDSEN
- Check whitening and dewhitening filters. We connected a binary output cable, but didn't checked them yet.
- Make a script for step 2
- Activate new DAQ channels for ETMX (what is the current new fresh up-to-date latest fb restart procedure?)
|
|
913
|
Tue Sep 2 22:43:16 2008 |
Yoichi | Configuration | PSL | Updated FSS open loop TF |
Since the LO level of the FSS servo was too low, I replaced the RF oscillator board with a combination of
a Stanford signal generator and an RF amplifier.
Right now, the POY RF amplifier is used for this purpose temporarily.
Now the LO level is about 16dBm. The RF power going into the EOM is attenuated by 20dB from the LO level.
I played with the cable length to get the phase right.
Then I was able to lock the FSS with the new RF signal source.
Attached is the open loop transfer function of the current FSS. Now the UGF is a bit above 200kHz, a factor of 2 improvement.
This gain was achieved with the common gain slider at 13.5dB and the fast gain = 30dB.
With the old RF oscillator board, UGF=100kHz was achieved with the common gain =30dB. Therefore, the increase of the LO gave
us a large signal gain.
Increasing the gain further, again ,makes the PC path crazy.
Rich suggested that this craziness was caused either by the slew rate limit of the PA85 or the output voltage limit of the bypass Op-amp(A829)
is hit.
TO DO:
* Look at the error signal spectrum to see if there is any signal causing the slew rate saturation at high frequencies.
* Find out what the RF signal level for the EOM should be. 20dB attenuation is an arbitrary choice.
* Find out the cross over frequency. Determine where the fast gain slider should be.
etc ... |
Attachment 1: OPLTF.png
|
|
14330
|
Tue Dec 4 10:38:12 2018 |
Jon | Omnistructure | Upgrade | Updated Feedthrough List for Vacuum Acromag Chassis |
Based on new input from Chub, attached is the revised list of signal cable feedthroughs needed on the vacuum system Acromag crate. I believe this list is now complete. |
Attachment 1: acromag_chassis_feedthroughs.pdf
|
|
4808
|
Mon Jun 13 12:34:21 2011 |
Jamie, Koji | Update | LSC | Updated LSC model installed |
After a couple of hickups, I was able to compile and install Koji's rework of the LSC model.
The main changes are that the model now use an RF_PD library part, and the channel names were tweaked to be more in line with what we expect.
I found a couple of small bugs in the model that were preventing it from compiling. Those were fixed and it compiled with no further problems.
There was also some rearrangement of signal inputs to the PD_DOF matrix. The matrix screen was updated to reflect the proper inputs. However, this also meant that the burt restore scripts for the IFO configurations were setting the wrong elements in the matrix. I fixed the settings for X and Y arm locking, and updated the burt snapshots using the burt/c1ifoconfigure/C1save{X,Y}arm scripts. NOTE: burt settings will need to be updated for the MICH, PRM, DRM, and FULL IFO configurations as well.
During the build/install process, Joe and I also found a bug in the feCodeGen that was causing the filter screens to be created with the wrong names. Joe sent out a patch that will hopefully be merged soon. Building the model with Joe's patch fixed the screen names, so the screens are currently named correctly. |
2610
|
Wed Feb 17 12:45:19 2010 |
josephb | Update | Computers | Updated Megatron and its firewall |
I updated the IP address on the Cisco Linksys wireless N router, which we're using to keep megatron separated from the rest of the network. I then went in and updated megatrons resolv.conf and host files. It is now possible to ssh into megatron again from the control machines. |
2392
|
Thu Dec 10 18:27:48 2009 |
Mott | Update | General | Updated R & T Measurements |
Attached are updated plots of the T&R Measurements for a variety of mirrors, and diagrams for the setup used to make the measurements.
T is plotted for the 1064 nm measurement, since these mirrors are highly reflective at 1064, and either R or R&T are plotted for the 532 nm measurement, depending on how larger the R signal is.
As with the previous set of plots, the error bars here are purely statistical, and there are certainly other sources of error not accounted for in these plots. In general, the T measurement was quite stable, and the additional errors
are probably not enormous, perhaps a few percent.
The mirrors are:
Y1-1037-00.50CC
Y1-2037-45S
Y1-2037-45P
Y1S-1025-0
Y1S-1025-45
|
Attachment 1: Y1S-0.png
|
|
Attachment 2: Y1S-45.png
|
|
Attachment 3: Y45P.png
|
|
Attachment 4: Y45S.png
|
|
Attachment 5: Y150CC.png
|
|
Attachment 6: Setup.png
|
|
3612
|
Mon Sep 27 17:35:13 2010 |
josephb | Update | CDS | Updated Suspension screens/Megatron now c1ioo/Further work on fb |
The medm screens have been updated further, with the hidden matrices added in bright colors. An example screen shot is attached.
Megatron has been renamed c1ioo and moved to martian network. Similarly, c1sus and c1iscex are also on the martian network. Medm screens can be run on any of the control machines and they will work.
Currently the suspension controller is running on c1sus.
The frame builder is currently running on the fb machine *however* it is not working well. Test points and daq channels on the new front ends tended to crash it when Alex started the mx_stream to the fb via our new DAQ network (192.168.114.XXX, accessible through the front ends or fb - has a dedicated 1 gigabit network with up to 10 gigabit for the fb). So for the moment, we're running without front end data. Alex will be back tomorrow to work on it.
Alex claimed to have left the frame builder in a state where it should be recording slow data, however, I can't seem to access recent trends (i.e. since we started it today). The frame builder throws up an error "Couldn't open raw minute trend file '/frames/trend/minute_raw/C1:Vac-P1_pressure', for example. Realtime seems to work for slow channels however. Remember to connect to fb, not fb40m. So it seems the fb is still in a mostly non-functional state.
Alex also started a job to convert all the old trends to the correct new data format, which should finish by tomorrow.
RA: Nice screen work. The old screens had a 'slow' slider effect when ramping the bias so that we couldn't whack the optic too hard. Is the new one instantaneous? |
Attachment 1: MC1_Example_Screen.png
|
|
3615
|
Tue Sep 28 10:07:29 2010 |
josephb | Update | CDS | Updated Suspension screens/Megatron now c1ioo/Further work on fb |
Quote: |
RA: Nice screen work. The old screens had a 'slow' slider effect when ramping the bias so that we couldn't whack the optic too hard. Is the new one instantaneous?
|
Looking at the sliders, I apparently still need to connect them properly. There's a mismatch between the medm screen channel name and the model name. At the moment there is no "slow" slider effect implemented, so they are effectively instantaneous. Talking with Alex, he suggests writing a little c-code block and adding it to the model. I can use the c code used in the filter module ramps as a starting point. |
13004
|
Mon May 22 15:01:41 2017 |
jigyasa | Update | telescope design | Updated Telescope design with 1'' eye piece |
I examined the use of a single lens system for the available range of focal lengths, for the required magnification and found that a focal length of at most 100 mm would be required to sufficiently cover the object distance range. This would greatly compromise with the f-number and hence lead to a lot more spherical aberrations.
Therefore, a two lens system would be more useful to implement. Using an eyepiece of 1” puts an additional constraint on the system such that the separation between the lenses must now at least equal or be greater than half the image distance from the first lens to ensure that no light from the light cone is lost. This is clarified in the schematic. The image from the first lens in absence of the second lens would form at point A, subtending an angle θ. In order to ensure that no part this light cone emerging from the first lens is lost, the second lens must be placed at a distance atleast v/2 from the first lens.
A combination of 125mm focal length 2” diameter objective with a 250 mm 1” eyepiece covers the required range of object distances (650mm to 1500 mm). Increasing the focal length of the eye piece increases the minimum object distance accessible to 700 mm.
A glance at the accessible u, v points shows that all magnifications are not possible at a given object distance. To image the entire surface of the test mass, a distance of at least 1.25m is required from the objective, while a beam spot of 1'' diameter can be imaged easily at upto 1200 mm from the objective . This holds true even for the 150-250 mm biconvex 2" lens combination proposed earlier.
If this sounds reasonable, we could proceed with ordering the lenses. |
Attachment 1: 1incep.pdf
|
|
11395
|
Wed Jul 8 17:46:20 2015 |
Jessica | Summary | General | Updated Time Delay Plots |
I re-measured the transfer function for Cable B, because the residuals in my previous post for cable B indicated a bad fit.
I also realized I had made a mistake in calculating the time delay, and calculated more reasonable time delays today.
Cable A had a delay of 202.43 +- 0.01 ns.
Cable B had a delay of 202.44 +- 0.01 ns. |
Attachment 1: resid_CableA.png
|
|
Attachment 2: resid_CableB.png
|
|
3978
|
Tue Nov 23 16:55:14 2010 |
josephb | Update | CDS | Updated apps |
Updated Apps:
I created a new setup script for the newest build of the gds tools (DTT, foton, etc), located in /opt/apps (which is a soft link from /cvs/cds/apps) called gds-env.csh.
This script is now sourced by cshrc.40m for linux 64 bit machines. In addition, the control room machines have a soft link in the /opt directory to the /cvs/cds/apps directory.
So now when you type dtt or foton, it will bring up the Centos compiled code Alex copied over from Hanford last month. |
3983
|
Tue Nov 23 23:52:49 2010 |
rana | Update | CDS | Updated apps |
Wow. I typed DTT on rossa and it actually worked! No complaints about testpoints, etc. I was also able to use its new 'NDS2' function to get data off of the CIT cluster (L1:DARM_ERR from February). You have to use the kinit/kdestroy stuff to use NDS2 as usual (look up NDS2 in DASWG if you don't know what I mean). |
2844
|
Mon Apr 26 11:29:37 2010 |
josephb | Update | Computers | Updated bitwise.pm in RCG SVN plus other fixes |
To fix a problem one of the models was having, I checked the CVS version of the Bitwise.pm file into the SVN (located in /home/controls/cds/advLigoRTS/src/epics/util/lib), which adds left and right bit shifting funtionality. The yec model now builds with the SVN checkout.
Also while trying to get things to work, I discovered the cdsRfmIO piece (used to read and write to the RFM card) now only accepts 8 bit offsets. This means we're going to have to change virtually all of the RFM memory locations for the various channels, rather than using the values from its previous incarnation, since most were 4 bit numbers. It also means it going to eat up roughly twice as much space, as far as I can tell.
Turns out the problem we were having getting to compile was nicely answered by Koji's elog post. The shmem_daq value was not set to be equal to 1. This caused it to look for myrimnet header files which did not exist, and caused compile time errors. The model now compiles on megatron.
[Edit by KA: 4 bit and 8 bit would mean "bytes". I don't recall which e-log of mine Joe is referring.]
|
16037
|
Thu Apr 15 17:24:08 2021 |
Jon | Update | CDS | Updated c1auxey wiring plan |
I've updated the c1auxey wiring plan for compatibility with the new suspension electronics. Specifically it is based on wiring schematics for the new HAM-A coil driver (D1100117), satellite amplifier (D1002818), and HV bias driver (D1900163).
Changes:
- The PDMon, VMon, CoilEnable, and BiasAdj channels all move from DB37 to various DB9 breakout boards.
- The DB9 cables (x2) connecting the CoilEnable channels to the coil drivers must be spliced with the dewhitening switching signals from the RTS.
- As suggested, I added five new BI channels to monitor the state of the CoilEnable switches. For lack of a better name, they follow the naming convention
C1:SUS-ETMY_xx_ENABLEMon .
@Yehonathan can proceed with wiring the chassis.
Quote: |
I finished prewiring the new c1auxey Acromag chassis (see attached pictures). I connected all grounds to the DIN rail to save some wiring. The power switches and LEDs work as expected.
I configured the DAQ modules using the old windows machine. I configured the gateway to be 192.168.114.1. The host machine still needs to be setup.
Next, the feedthroughs need to be wired and the channels need to be bench tested.
|
|
Attachment 1: C1AUXEY_Chassis_Feedthroughs_-_By_Connector.pdf
|
|
16052
|
Mon Apr 19 21:54:55 2021 |
Yehonathan | Update | CDS | Updated c1auxey wiring plan |
Except for the feed-throughs that require a DB9-M connector I finished wiring and labeling the Acromag, following Jon's updated wiring plan.
We can start testing the differential inputs until the missing connectors arrive.
|
16092
|
Wed Apr 28 18:56:57 2021 |
Yehonathan, Jon | Update | CDS | Updated c1auxey wiring plan |
We took a Supermicro from the lab (along with a keyboard, a mouse, and a screen taken from a table on the Y arm) and placed it near the Acromag chassis.
We installed Debian 10 on the machine. I followed the steps on the slow machine wiki for setting up the host machine. Some steps had to be updated. Most importantly, in the new Debian, the network interfaces are given random names like enp3s0 and enp4s0 instead of eth0 and eth1. I updated the wiki accordingly.
To operate the chassis using one 15V source I disconnected the +24V cable from the Acromag units and jumpered the +15V wire into the power input instead. I started up the Acromags. They draw 0.7A. I connected an Ethernet cable to the front interface. I checked that all the Acromags are connected to the local network of the host machine by pinging them one by one.
|
16098
|
Thu Apr 29 16:35:51 2021 |
Yehonathan | Update | CDS | Updated c1auxey wiring plan |
I installed the EPICs base, asyn and modbus modules according to Jon's instructions.
Since the modbus configurations files were already writtten for c1auxey1 (see elog 15292) the only thing I did was to change the IP addresses in ETMYaux.cmd to match the actual assigned IPs.
I followed the rest of the instructions as written.
The modbus service was activated succesfully.
The only thing left to do is to change ETMYaux.db to reflect to new channels that were added. I believe these are BI channels named C1:SUS-ETMY_xx_ENABLEMon.
|
16103
|
Thu Apr 29 19:55:45 2021 |
Yehonathan | Update | CDS | Updated c1auxey wiring plan |
We received a stock of DB9 male feed-through connectors. That allowed me to complete the remaining wiring on the c1auxey Acromag chassis. The only thing left to be done is the splicing to the RTS.
|
16107
|
Fri Apr 30 19:18:51 2021 |
Yehonathan, Jon | Update | CDS | Updated c1auxey wiring plan |
We finished the installation procedure on the c1auxey1 host machine. There were some adjustments that had to be made for Debian 10. The slow machine wiki page has been updated.
A test database file was made were all the channel names were changed from C1 to C2 in order to not interfere with the existing channels.
We starting testing the channels one by one to check the wiring and the EPICs software. We found some misswirings and fixed them.
Channel Name |
Type |
EPICs Test |
Acromag windows software test |
C2:SUS-ETMY_ULPDMon |
AI |
Pass |
Pass |
C2:SUS-ETMY_URPDMon |
AI |
Pass |
Pass |
C2:SUS-ETMY_LLPDMon |
AI |
Pass |
Pass |
C2:SUS-ETMY_SPDMon |
AI |
Pass |
Pass |
C2:SUS-ETMY_LRPDMon |
AI |
Pass |
Pass |
C2:SUS-ETMY_ULVMon |
AI |
Pass |
Pass |
C2:SUS-ETMY_URVMon |
AI |
Pass |
Pass |
C2:SUS-ETMY_LLVMon |
AI |
Pass |
Pass |
C2:SUS-ETMY_SideVMon |
AI |
Pass |
Pass |
C2:SUS-ETMY_LRVMon |
AI |
Pass |
Pass |
Its getting late. I'll continue with the rest of the channels on Monday.
Notice that for all the AI channels the RTN was disconnected while testing.
|
16114
|
Mon May 3 20:36:46 2021 |
Yehonathan, Jon | Update | CDS | Updated c1auxey wiring plan |
It seemed like the BIO channels were not working, both the inputs and the outputs. The inputs were working on the windows machine though. That is, when we shorted the BIO channel to the return, or put 0V on it, we could see the LED turn on on the I/O testing screen and when we ramped up the voltage above 3 the LED turned off. This is the expected behavior from a sinking digital input. However, the EPICs caget didn't show any change. All the channels were stuck on Disabled.
We checked the digital outputs by connecting the channels to a fluke. Initially, the fluke showed 13V. We tried to toggle the digital output channels with caput and that didn't work. We checked the outputs with the windows software. For that, we needed to stop the Modbus. To our surprise, the windows software was not able to flip the channels either. We realized that this BIO Acromag unit is probably defective. We replaced it with a different unit and put a warning sticker on the defective unit. Now, the digital outputs were working as expected. When we turned them on the voltage output dropped to 0V. We checked the channels with the EPICs software. We realized that these channels were locked with the closed loop definition. We turned on the channels tied to these output channels (watchdog and toggles) and it worked. The output channels can be flipped with the EPICs software. We checked all the digital output channels and fixed some wiring issues along the way.
The digital input channels were still not working. This is a software issue that we will have to deal with later.
(Yehonathan) Rana noticed that the BNC leads on the chassis front panel didn't have isolation on them so I redid them with shrinking tubes. |
4200
|
Tue Jan 25 15:20:38 2011 |
josephb | Update | CDS | Updated c1rfm model plus new naming convention for RFM/Dolphin |
After sitting down for 5 minutes and thinking about it, I realized the names I had been using for internal RFM communication were pretty bad. It was because looking at a model didn't let you know where the RFM connection was coming from or going to. So to correct my previous mistakes, I'm instituting the following naming convention for reflected memory, PCIE reflected memory (dolphin) and shared memory names. These don't actually get used anywhere but the models, and thus don't show up as channel names anywhere else. They are replaced by raw hex memory locations in the actual code through the use of the IPC file (/opt/rtcds/caltech/c1/chans/ipc/C1.ipc). However it will make understanding the models easier for anyone looking at them or modifying them.
The new naming convention for RFM and Dolphin channels is as follows.
SITE:Sending Model-Receiving Model_DESCRIPTION_HERE
The description should be unique to that data being transferred and reused if its the same data. Thus if its transfered to another model, its easy to identify it as the same information.
The model should be the .mdl file name, not the subsystem its a part of. So SCX is used instead of SUS. This is to make it easier to track where data is going.
In the unlikely case of multiple models receiving, it should be of the form SITE:Sending Model-Receiving Model 1-Receiving Model 2_DESCRIPTION_HERE. Seperate models by dashes and description by underscores.
Example:
C1:LSC-RFM_ETMX_LSC
This channel goes from the LSC model (on c1lsc) to the RFM model (on c1sus). It transfers ETMX LSC position feedback. The second LSC may seem redundant until we look at the next channel in the chain.
C1:RFM-SCX_ETMX_LSC
This channel goes from the RFM model to the SCX model (on c1iscex). It contains the same information as the first channel, i.e. ETMX LSC position feedback.
I have updated all the models that had RFM and SHMEM connections, as well as adding all the LSC communciation connections to c1rfm. This includes c1sus, c1rfm, c1mcs, c1ioo, c1gcv, c1lsc, c1scx, c1scy. I have not yet built all the models since I didn't finish the updates until this afternoon. I will build and test the code tomorrow morning.
|
4265
|
Wed Feb 9 15:26:22 2011 |
josephb | Update | CDS | Updated c1scx with lockin, c1gcv for green transmission pd |
Updated the c1scx model to have two Lockin demodulators (C1:SUS-ETMX_LOCKIN1 and C1:SUS-ETMX_LOCKIN2). There is a matrix C1:SUS-ETMX_INMUX which directs signals to the inputs of LOCKIN1 and LOCKIN2. Currently only the GREEN_TRX signal is the only signal going in to this matrix, the other 3 are grounds. The actual clocks themselves had to be at the top level (they don't work inside blocks) and thus named C1:SCX-ETMX_LOCKIN1_OSC and C1:SCX-ETMX_LOCKIN2_OSC.
There is a signal (IPC name is C1:GCV-SCX_GREEN_TRX) going from the c1gcv model to the c1scx model, which will contain the output from Jenne's green transmission PD which will eventually be placed. I've placed a filter bank on it in the c1gcv model as a monitor point, and it corresponds to C1:GCV-GREEN_TRX.
The suspension control screens were modified to have a screen for the Matrix feeding signals into the two lockin demodulators. The green medm screen was also modified to have readbacks for the GREEN_TRX and GREEN_TRY channels.
So on the board, the top channel (labeled 1, corresponds to code ADC_0_0) is MCL.
Channel 2 (ADC_0_1) is assigned to frequency divided green signal.
Channel 3 (ADC_0_2) is assigned to the beat PD's DC output.
Channel 4 (ADC_0_3) is assigned to the green power transmission for the x-arm.
Channel 5 (ADC_0_4) is assigned to the green power transmission for the y-arm. |
3715
|
Thu Oct 14 10:59:10 2010 |
josephb | Update | Computers | Updated cshrc.40m and Computer Restart Procedures |
I started modifying the cshrc.40m file in /cvs/cds/caltech/ so that it starts pointing at the new directories.
# misc aliases
alias target 'cd /opt/rtcds/caltech/c1/target'
alias scripts 'cd /opt/rtcds/caltech/c1/scripts'
alias chans 'cd /opt/rtcds/caltech/c1/chans'
alias c 'cd /opt/rtcds/caltech/c1'
alias s 'cd /opt/rtcds/caltech/c1/scripts'
alias u 'cd /cvs/cds/caltech/users'
I also added "alias screens 'cd /opt/rtcds/caltech/c1/medm'" as a quick way to get to the medm directory.
Once we get multiple compiled versions (i.e. i386, x86_64, Solaris) of the new gds tools from Alex, we'll have to some more serious surgery on this file.
I removed the "New Computer Restart Procedures" and simply moved the changes into the "Computer Restart procedures", found here. I've removed everything I don't think applies anymore (all the VME FE reboot procedures for example). |
6161
|
Tue Jan 3 17:46:38 2012 |
Updated Stewart platform design requirements | Update | General | Updated design requirements for a Stewart platform |
I updated the design requirements for the Stewart platform. I weighed the unloaded "dirty" SOS that was sitting on the workbench in the control room; its mass is 11 kg. Steve suggested that the OSEMs (not installed on this model) would add another 0.5 kg. From the specs in the final SOS design document, LIGO-T970135, I added 0.25 kg for the optic itself; I am therefore taking the total payload mass to be 11.75 kg. (Now, the upper stage of the Stewart platform itself will likely add a nontrivial amount, but I am not worrying about this yet.)
I have e-mailed Janeen Romie to obtain the actual center of mass and principal moments of inertia of the platform. I also cooked up a simple scheme to measure both quantities, should this information not be available. It would involve rigidly mounting the dirty SOS to a rigid bar hung from a pivot. By translating the mount point in two dimensions and measuring the period of the pendulum, I ought to be able to find the center of mass and moments of inertia by multilinear regression. However, this elaborate scheme is not necessary to just compute some ballpark figures; it could wait until a later stage in the design. For the time being, I just rescaled the moment of inertia proportional to the increase in mass, such that the torque-to-force ratio is unchanged.
As such, the design requirements are now
- linear travel: 40 microns peak to peak (based on SOS design requirements in LIGO-T950011)
- angular travel: 3 mrad peak to peak (based on SOS design requirements in LIGO-T950011)
- payload mass: 11.75 kg (measured unloaded mass, plus educated guesses about combined mass of OSEMs and optic)
- payload moment of inertia: 0.0232 kg m^2 (wild guess)
- bandwidth: 500 Hz (suggestion of Rana and Koji: ~kHz)
From these assumptions, the revised actuator requirements and dimensions are:
- peak actuator force: 2.04 kN
- minimum radius of top platform: 15 cm
- minimum radius of bottom platform: 30 cm
- minimum height: 26 cm
See the attached PDF document.
It appears that the actuator that I had originally nominated, PI's model P-225.80, would very nearly meet the actuator force requirement. Steve also pointed out the following single-axis shakers that are already in use in the 40m:
- Brüel & Kjær type 4809
- Brüel & Kjær type 4810
I want to find out if either of these would meet the present need, but I'm waiting on a response from the manufacturer to get access to the data sheets.
|
Attachment 1: stewart.pdf
|
|
10383
|
Thu Aug 14 14:58:03 2014 |
Jenne | Update | General | Updated game plan |

(Updated as of 4pm) |
10385
|
Thu Aug 14 15:42:29 2014 |
Koji | Update | General | Updated game plan |
- ALS
End PDH UGF improvement / post mixer LPF investigation (with in 2 weeks)
- MC/FSS
Riju measured the MC REFL PD transimpedance. See ELOG and related.
- ASC
Why do we want to see less PRM motion? I thought PRC motion was causing
LSC issue of the central part. We wanted to maximize the PRM effect, don't we?
(Or is this to supress ETM motion during full lock?) |
10386
|
Thu Aug 14 15:51:37 2014 |
Jenne | Update | General | Updated game plan |
Quote: |
- ALS
End PDH UGF improvement / post mixer LPF investigation (with in 2 weeks)
- MC/FSS
Riju measured the MC REFL PD transimpedance. See ELOG and related.
- ASC
Why do we want to see less PRM motion? I thought PRC motion was causing
LSC issue of the central part. We wanted to maximize the PRM effect, don't we?
(Or is this to supress ETM motion during full lock?)
|
End PDH - good point, thanks.
ASC - Yes, this is so that we can use the POP QPD to feed back to the common ETMs after the CARM offset is already quite small. We will not use POP DC QPD for PRC any more.
Also, for future PRC ASC, I keep coming back to this in my head, but maybe it is less painful to install oplevs for PR2, PR3 than it would be to make an RF QPD. Neither is going to be trivially easy. But if we had sensors of the tip tilt motions, we could feed all of that back to the PRM to stabilize the PRC. |
10387
|
Thu Aug 14 18:02:11 2014 |
Koji | Update | General | Updated game plan |
Got the idea of ASC.
- Oplevs for PR2, PR3 => PR2 seems OK. PR3 almost impossible. well turned out not too crazy. We need outside electronics.
- RF QPD => not trivial and very technical but possible. All outside work.
- Better TT => might be a good solution. |
10388
|
Thu Aug 14 18:05:05 2014 |
Jenne | Update | General | Updated game plan |
Quote: |
- Oplevs for PR2, PR3 => Almost impossible.
|
Because of the limited table space inside? That's the main reason I can think of that this method is hard. Am I missing something? |
10423
|
Fri Aug 22 13:51:00 2014 |
Jenne | Update | General | Updated game plan |

|
4212
|
Thu Jan 27 15:16:43 2011 |
josephb | Update | CDS | Updated generate_master_screens.py |
I modified the generate_master_screens.py script in /opt/rtcds/caltech/c1/medm/master/ to handle changing the MCL (and MC_L) listings to ALS for the two ETM suspension screens and associated sub-screens.
The relevant added code is:
custom_optic_channels = ['ETMX',
{'MCL':'ALS','MC_L':'ALS'},
'ETMY',
{'MCL':'ALS','MC_L':'ALS'}]
for index in range(len(custom_optic_channels)/2):
if optic == custom_optic_channels[index*2]:
for swap in custom_optic_channels[index*2+1]:
sed_command = start_sed_string + swap + "/" + custom_optic_channels[index*2+1][swap] + middle_sed_string + optic + file
os.system(sed_command)
When run, it generates the correctly named C1:SUS-ETMX_ALS channels, and replaces MCL and MC_L with ALS in the matrix screens.
|
11745
|
Tue Nov 10 02:34:28 2015 |
gautam | Update | LSC | Updated interpretation of peaks |
After thinking about the interpretation of the various peaks seen in the scan through 2 FSRs, I have revised the information presented in the previous elog. Yutaro pointed out that the modulation frequency isn't exactly 11MHz, but according to this elog, is 11.066209 MHz. So instead of using mod(11e6,FSR), I really should have been using mod(11.066209,FSR) and mod(5*11.066209,FSR) to locate the positions of the 11MHz and 55MHz sidebands relative to the carrier resonances. With this correction, the 'unknown' peaks identified in Attachment #1 in elog 11743 are in fact the 55MHz sideband resonances.
However, this means that the peaks which were previously identified as 55MHz sideband resonances have to be interpreted now - I'm having trouble identifying these. If we assume that the types of peaks present in the scan are 11 MHz sideband, 55MHz sideband, and the TEM00, TEM10, TEM20, TEM30, and TEM40 mode resonances, then the peaks marked in grey in Attachment #1 to this elog can be interpreted as TEM30 (right of a carrier resonance) and TEM40 (left of a carrier resonance) mode resonances - however, the fitted center frequencies differ from the expected center frequencies (determined using the same method as elog 469) by ~3% (for TEM30) and ~20% (for TEM40) - therefore I am skeptical about these peaks, particularly the 4th HOM resonances. In any case, they are the smallest of all the peaks, and any correction due to them will be small.
The updated modulation depths are as follows (computed using the same method as described in elog 11743, the updated plot showing the ratio of bessel functions as a function of the modulation depth is Attachment #2 in this elog):
@11.066209 MHz ---- 0.179
@5*11.066209 MHz --- 0.226
These numbers are now reasonably consistent with those reported in elog10211.
As for the mode-matching efficiency, the overall number is almost unchanged if I assume the TEM30 peaks are accurately interpreted: 92.11%. But the dominant HOM contribution comes from the first HOM resonance: (TEM00 = 1, TEM20 = 0.0325, TEM10 = 0.0475, TEM30 = 0.0056). These numbers may change slightly if the 4th HOM resonances are also correctly identified.
ETMx is still not well behaved and the mode cleaner isnt too happy either, so I think we will save the measurement of the round trip arm loss for daytime tomorrow. |
Attachment 1: Y_scan.pdf
|
|
Attachment 2: modDepth.pdf
|
|
11746
|
Tue Nov 10 11:06:02 2015 |
yutaro | Update | LSC | Updated interpretation of peaks |
Quote: |
Quote: |
- modulation depth = 0.390 +/- 0.062
|
There are two modulation frequencies that make it to the arm cavities, at ~11MHz and ~55MHz. Each of these will have their own modulation depth indepedent of each other. Bundling them together into one number doesn't tell us what's really going on.
|
I'm sorry. I misunderstood two things when writing elog 11741: the number of modulation frequencies, and how to distinguish modulation peaks and HOM peaks.
Now, I report about interpretation of the peaks marked in grey in Attachment #1 in elog 11745.
Summary:
The peaks marked in grey are interpreted as 3rd and 4th HOM resonance, if we assume that the radius of curvature of ETMY is slightly different from measured value. (measured: 57.6 m --> assumed: 59.3 m)
What I have done:
I plotted the differences in frequency between HOM peaks and 00 mode peaks (see Attachment #1) vs. expected orders of modes. The plot is shown in Attachement #2.
By fitting these data points, I calculated most likely value of gradient of this plot. This value corresponds: g_ITMYg_ETMY=0.3781. However, measured data of the radii of curvature suggests that g_ITMYg_ETMY=0.358. Assuming that this disagreement comes from the difference between measured and real values of ROC of ETMY (ITM is almost flat so that change of ROC of ITM doesn't have significant effect on g_ITMg_ETM), ROC of ETMY should be 59.3 m, different from measured value 57.6 m.
What I'd like to know:
-- Is such disagreement of ROC usual? Could it happen?
-- Are there any other possible explanations for this disagreement (or interpretations of the peaks marked in grey)? |
Attachment 1: HOMlocation.png
|
|
Attachment 2: homfit.png
|
|
11747
|
Tue Nov 10 11:40:03 2015 |
Koji | Update | LSC | Updated interpretation of peaks |
What is the uncertainty of your RoC estimation?
One measurement of the ETMY ROC was 57.6m, but we trust another measured value of 60.26m than the other.
The value is always dependent on the spotposition on the mirror and how the ROC is calculated from the mirror phase map (e.g. spotsize, averaging method).
So I don't think this is a huge deviation from the spec. |
11748
|
Tue Nov 10 11:41:56 2015 |
Koji | Update | LSC | Updated interpretation of peaks |
FYI: I've also reported the similar mod depths of
11M: 0.194
55M: 0.234
in ELOG11036 with a different kind of measurement method. |
11749
|
Tue Nov 10 16:34:00 2015 |
yutaro | Update | LSC | Updated interpretation of peaks |
Quote: |
What is the uncertainty of your RoC estimation?
|
The uncertainty came from the residual of linear fitting and based on my estimation,
ROC_ETMY = 59.3 +/- 0.1 m.
And I attach the updated figure of the fitting (with residual zoomed up).
Data points in the lower are (intentionally) slightly shifted horizontally to make it easy for us to see them.
It is hard, I think, to estimate the error of each data point, but I used 17 kHz for the errors of all data points; 17 kHz is the error of FSR estimation of this measurement, and since FSR is the distance between two carrier peaks we can consider that HOM distances, which are the distance between carrier peaks and HOM peaks, have similar order errors comared with that of FSR. |
Attachment 1: homfit2.png
|
|
2872
|
Mon May 3 16:53:27 2010 |
josephb | Update | CDS | Updated lsc.mdl and the ifo plant model with memory locations |
I've updated the LSC and IFO models that Rana created with new shared memory locations. I've used the C1:IFO- for the ifo.mdl file outputs, which in turn are read by the lsc.mdl file. The LSC outputs being lsc control signals are using C1:LSC-. Optics positions would presumably be coming from the associated suspension model, and am currently using SUP, SPX, and SPY for the suspension plant models (suspension vertex, suspension x end, suspension y end).
I've updated the web view of these models on nodus. They can be viewed at: https://nodus.ligo.caltech.edu:30889/FE/
I've also created a C1.ipc file in /cvs/cds/caltech/chans/ipc which assigns ipcNum to each of these new channels in shared memory. |
4344
|
Wed Feb 23 11:53:30 2011 |
josephb | Update | CDS | Updated mx drivers |
Alex and I updated the open mx drivers from 1.3.3 to 1.3.901 (1.4 release candidate). We downloaded the drivers from: http://open-mx.gforge.inria.fr/
We put them in /root/open-mx-1.3.901 on the fb machine (and thus get mounted by all the front ends.). We did configure and make and make install.
We did a quick check with /opt/mx/bin/mx_info on the fb machine at this point and realized the MAC addresses and host names were all messed up, including two listings for c1iscex with different mac addresses (neither of which was c1iscex).
We then brought all the front ends mx_streams down, brought the fb down, then cleared all the peer names with mx_hostname. We then brought the fb up, and the front end mx_stream processes.
/opt/mx/mx_info now shows a clean and correct set of hostnames and mac addresses. Testpoints and trends are working. |
3546
|
Wed Sep 8 14:44:37 2010 |
josephb | Update | CDS | Updated parse_mdl_to_ipc.py and feCodeGen.pl |
I updated parse_mdl_to_ipc.py to correctly work with the 3 new cdsIPCx parts, namely cdsIPCx_PCIE (for dolphin connections), cdsIPCx_RFM (for our traditional reflected memory connections), and cdsIPCx_SHMEM (local shared memory on the computer). These parts replaced cdsIPCx awhile back (see here ).
The code now correctly counts each type independantly with regards to ipcNum (I.e. you can have ipcNum = 0 for RFM and ipcNum = 0 for SHMEM for example).
I also went in and modified a few sections of the feCodeGen.pl (in /opt/rtcds/caltech/c1/core/advLigoRTS/src/epics/util/) so as to properly assign names to matrix adl files, matrix of filter bank adl files, and filter bank adl files. |
15429
|
Wed Jun 24 22:47:21 2020 |
Yehonathan | Update | Wiki | Updated phase maps webpage |
I uploaded the new phase maps measurements made by GariLynn to nodus and updated the optics phase maps page.
I also added MetroPro and Matlab analysis for these phase maps. |