ID |
Date |
Author |
Type |
Category |
Subject |
4253
|
Fri Feb 4 23:39:56 2011 |
rana, koji | Update | LSC | mixer based FD set up for noise test |
We set up the mixer based FD to check out its noise performance.
It is being acquired as C1:GCV-XARM_FINE_OUT_DAQ.
We have calibrated it by driving the frequency of the RF signal generator and putting the value into the GAIN field. We got 100 kHz / 5450 counts; the _OUT_DAQ channel is now being recorded in units of Hz. The cable length has been adjusted so that the full mixer output can swing 16 MHz peak-peak before turning over.
Also, we did a lot of cable cleanup around the IO rack. Kiwamu and Suresh's setups were somewhat dismantled. The whole area was too messy and too hacky to be allowed to survive. Our "temporary" setups have a way of becoming permanent holding places for barrels, adapters, duct tape, etc. |
4252
|
Fri Feb 4 18:58:19 2011 |
rana | Update | Computers | Temporarily removed cronjob for rsync.backup |
Quote: |
I removed the rsync backup from nodus' crontab temporarily so as to not have multiple backup jobs running. The job I started from yesterday was still running. Hopefully the backup will finish by Monday.
The line I removed was:
0 5 * * * /opt/rtcds/caltech/c1/scripts/backup/rsync.backup
|
Actually, this is not true. Joe actually killed the currently running backup and set it to start tomorrow morning at 6AM. Its taking forever since its not an incremental backup but a new one due to the change in the setup. |
4251
|
Fri Feb 4 15:03:20 2011 |
josephb | Update | Computers | Modified cshrc.40m |
Removed some lines from the PATH environment variable since they point to old codes which no longer work with the new frame builder and setup.
The change was:
#setenv PATH $LINUXPATH/bin:$GDSPATH/bin:$ROOTSYS/bin:$TDSPATH/bin:${SCRIPTPATH}:$PATH
setenv PATH $TDSPATH/bin:${SCRIPTPATH}:$PATH
|
4250
|
Fri Feb 4 13:45:25 2011 |
josephb | Update | Computers | Temporarily removed cronjob for rsync.backup |
<p>I removed the rsync backup from nodus' crontab temporarily so as to not have multiple backup jobs running. The job I started from yesterday was still running. Hopefully the backup will finish by Monday.</p>
<p>The line I removed was:</p>
<p>0 5 * * * /opt/rtcds/caltech/c1/scripts/backup/rsync.backup</p>
<table align="left" width="786" cellspacing="1" cellpadding="1" border="2">
<tbody>
<tr>
<td><span style="font-size: larger;">MC damp</span></td>
<td><span style="font-size: larger;">dataviewer</span></td>
<td><span style="font-size: larger;">diaggui</span></td>
<td><span style="font-size: larger;">AWG</span></td>
<td><span style="font-size: larger;">c1lsc</span></td>
<td><span style="font-size: larger;">c1ioo</span></td>
<td><span style="font-size: larger;">c1sus</span></td>
<td><span style="font-size: larger;">c1iscex</span></td>
<td><span style="font-size: larger;">c1iscex</span></td>
<td><span style="font-size: larger;">RFM</span></td>
<td><span style="">The Dolphins</span></td>
<td><span style="font-size: larger;">Sim.Plant</span></td>
<td><span style="font-size: larger;">Frame builder</span></td>
<td><span style="font-size: larger;">TDS</span></td>
<td><span style="font-size: larger;">Cabling</span></td>
</tr>
<tr>
<td bgcolor="blue"><span style="font-size: larger;"> </span></td>
<td bgcolor="green"><span style="font-size: larger;"> </span></td>
<td bgcolor="blue"><span style="font-size: larger;"> </span></td>
<td bgcolor="yellow"><span style="font-size: larger;"> </span></td>
<td bgcolor="orange"><span style="font-size: larger;"> </span></td>
<td bgcolor="yellow"><span style="font-size: larger;"> </span></td>
<td bgcolor="blue"><span style="font-size: larger;"> </span></td>
<td bgcolor="yellow"><span style="font-size: larger;"> </span></td>
<td bgcolor="yellow"><span style="font-size: larger;"> </span></td>
<td bgcolor="blue"><span style="font-size: larger;"> </span></td>
<td bgcolor="blue"><span style="font-size: larger;"> </span></td>
<td bgcolor="red"><span style="font-size: larger;"> </span></td>
<td bgcolor="blue"><span style="font-size: larger;"> </span></td>
<td bgcolor="orange"><span style="font-size: larger;"> </span></td>
<td bgcolor="orange"><span style="font-size: larger;"> </span></td>
</tr>
</tbody>
</table> |
4249
|
Fri Feb 4 13:31:16 2011 |
josephb | Update | CDS | FE start scripts moved to scripts/FE/ from scripts/ |
All start and kill scripts for the front end models have been moved into the FE directory under scripts: /opt/rtcds/caltech/c1/scripts/FE/. I modified the Makefile in /opt/rtcds/caltech/c1/core/advLigoRTS/ to update and place new scripts in that directory.
This was done by using
sed -i 's[scripts/start$${system}[scripts/FE/start$${system}[g' Makefile
sed -i 's[scripts/kill$${system}[scripts/FE/kill$${system}[g' Makefile
|
4248
|
Fri Feb 4 11:10:27 2011 |
Suresh | Update | Green Locking | VCO PLL Frequency noise |
This measurement pertains to the BL2002 VCO PLL unit.
Our goal is to measure the frequency fluctuations introduced by the VCO.
First the VCO calibration was checked. It is -1.75 MHz per volt. The calibration data is below:

Next we measured the Transfer function between points A and B in the diagram below using the Stanford Research System's SR785. This measurement was done with loop opened just after the 1.9MHz LPF and with the loop closed.

The TF[open] / TF [closed ] gave the total gain in the loop. As shown below:

Green curve is the Transfer Function with the loop open and the red with that of the loop closed.
Gain Shown below is the quotient TF[open]/TF[closed]

c) As can be seen from the graph above the loop gain is >>1 over 0.1 to 300Hz. And hence the frequency noise of the VCO is just the product of the voltage noise and the VCO calibration factor over this range,
d) the noise power at the point B was measured and multiplied by the VCO calibration factor to yield dF(rms)/rtHz:

The green line with dots are the data
The blue line is the rms frequency fluctuation.
This corresponds to a arm length fluctuation of about 20pm.
|
4247
|
Thu Feb 3 17:25:03 2011 |
josephb | Update | Computers | rsync script was not really backing up /cvs/cds |
So today, after an "rm" error while working with the autoburt.pl script and burt restores in general, I asked Dan Kozak how to actually look at the backup data. He said there's no way to actually look at it at the moment. You can reverse the rsync command or ask him to grab the data/file if you know what you want. However, in the course of this, we realized there was no /cvs/cds data backup.
Turns out, the rsync command line in the script had a "-n" option. This means do a dry run. Everything *but* the actual final copying.
I have removed the -n from the script and started it on nodus, so we're backing up as of 5:22pm today.
I'm thinking we should have a better way of viewing the backup data, so I may ask Dan and Stewart about a better setup where we can login and actually look at the backed up files.
In addition, tomorrow I'm planning to add cron jobs which will put changes to files in the /chans and /scripts directories into the SVN on a daily basis, since the backup procedure doesn't really provide a history for those, just a 1 day back backup. |
4246
|
Thu Feb 3 16:45:28 2011 |
josephb | Update | CDS | General CDS updates |
Updated the FILTER.adl file to have the yellow button moved up, and replaced the symbol in the upper right with a white A with black background. I made a backup of the filter file called FILTER_BAK.adl. These are located in /opt/rtcds/caltech/c1/core/advLigoRTS/src/epics/util.
I also modified the Makefile in /opt/rtcds/caltech/c1/core/advLigoRTS/ to make the startc1SYS scripts it makes take in an argument. If you type in:
sudo startc1SYS 1
it automatically writes 1 to the BURT RESTORE channel so you don't have to open the GDS_TP screen and by hand put a 1 in the box before the model times out.
The scripts also points to the correct burtwb and burtrb files so it should stop complaining about not finding them when running the scripts, and actually puts a time stamped burt snapshot in the /tmp directory when the kill or start scripts are run. The Makefile was also backed up to Makefile_bak.
|
4245
|
Thu Feb 3 16:08:06 2011 |
Aidan | Update | Computer Scripts / Programs | RCG VCO frequency error |
Joe and I were looking at the RCG VCO algorithm to determine if we could adapt it to run at a faster rate (you can currently change its frequency at 1Hz). I noticed that the algorithm that is used to calculated the values of sine and cosine at time T1 is a truncated Taylor series which uses the values of sine and cosine calculated at time T1 - Delta t . I was concerned that there would be an accumulating phase error so I tested the algorithm in MATLAB and compared it to a proper calculation of sine and cosine. It turns out that at a given 'requested' frequency there is a constantly accumulating phase error - which means that the 'actual' frequency of the RCG VCO is incorrect. So I have plotted the frequency error vs requested VCO frequency. It gets pretty bad!
Here's the code I used:
dt = 1/16384;
diffList = [];
% set the frequencies
flist = 1:5:8192;
for f = flist;
% get the 'accurate' values of sine and cosine
tmax = 0.05;
time1 = dt:dt:tmax;
sineT = sin(2.0*pi*f*time1);
cosineT = cos(2.0*pi*f*time1);
% determine the phase change per cycle
dphi = f*dt*2*pi;
cosT1 = 1:numel(time1);
sinT1 = 0*(1:numel(time1));
% use the RCG VCO algorithm to determine the values of sine and cosine
for ii = 1:numel(time1) - 1;
cosNew = cosT1(ii)*(1 - 0.5*dphi^2) ...
- (dphi)*sinT1(ii);
sinNew = sinT1(ii)*(1 - 0.5*dphi^2) ...
+ (dphi)*cosT1(ii);
cosT1(ii+1) = [ cosNew];
sinT1(ii+1) = [ sinNew];
end
% extract the phase from the VCO values of sine and cosine
phaseT = unwrap(angle(cosineT + i* sineT));
phaseT1 = unwrap(angle((cosT1 + i*sinT1)));
% determine the phase error for 1 cycle
diff = phaseT1 - phaseT;
% determine the frequency error
slope = (diff(2) - diff(1))/(dt);
diffList = [diffList, slope];
disp(f)
pause(0.001)
end
% plot the results
close all
figure
orient landscape
loglog(flist, abs(diffList/(2.0*pi)))
xlabel('Requested VCO Frequency (Hz)')
ylabel('Frequency error (Hz)')
grid on
print('-dpdf', '/users/abrooks/VCO_error.pdf')
|
Attachment 1: VCO_error.pdf
|
|
4244
|
Thu Feb 3 11:13:52 2011 |
Koji | Update | Electronics | POY Shot Noise and Dark Spectrum |
I wonder why POY11 has the dark noise level of 90nV/rtHz that is 5 times larger than that of POX (18nV/rtHz)
even though the Q are the same (~15) and the transimpedance is better (3.9k instead of 2k).
What cause this high noise level?
What is the expected dark noise level?
Quote: |
[Koji and Kevin]
I measured the shot noise of POY and fit the data to determine the RF transimpedance at 11 MHz and the dark current. The transimpedance is (3.860 +- 0.006) kΩ. I realize that there are not many data points past the dark current but I did not want to take any further data because the light bulb was getting pretty bright. If this is a problem, I can try to redo the measurement using a lens to try to focus more of the light from the bulb onto the photodiode.
I also measured the spectrum and recorded a time series of the RF signal with the light to the photodiode blocked. These measurements do not show any large oscillations like the ones found for POX.
The plots of the measurements are on the wiki at http://lhocds.ligo-wa.caltech.edu:8000/40m/Electronics/POY.
|
|
4243
|
Thu Feb 3 04:43:58 2011 |
Suresh | Update | Electronics | Added two new DAQ channels |
[Suresh, Joe]
We added the following two new DAQ channels into the c1:GCV model. The daq:analog input channels are on card ADC0 and correspond to channels 3 and 4 on the card.
c1:GCV-EXT_REF_OUT_DAQ Sampling rate=2kHz acquiring a 1Hz sine wave from the SRS Function Generator DS345. This is using the Rb 10MHz signal as an external frequency reference.
c1:GCV-PLL_OUT_DAQ Sa.rate=2kHz acquiring the demodulated signal from the PLL servo.
This work is connected to the study of VCO PLL loop noise at frequencies below 0.1Hz. We are trying to measure phase noise in the VCO PLL servo at low frequencies as this noise would result in arm length fluctuations in the green-locking scheme.
|
4242
|
Thu Feb 3 01:46:54 2011 |
Kevin | Update | Electronics | POY Shot Noise and Dark Spectrum |
[Koji and Kevin]
I measured the shot noise of POY and fit the data to determine the RF transimpedance at 11 MHz and the dark current. The transimpedance is (3.860 +- 0.006) kΩ. I realize that there are not many data points past the dark current but I did not want to take any further data because the light bulb was getting pretty bright. If this is a problem, I can try to redo the measurement using a lens to try to focus more of the light from the bulb onto the photodiode.
I also measured the spectrum and recorded a time series of the RF signal with the light to the photodiode blocked. These measurements do not show any large oscillations like the ones found for POX.
The plots of the measurements are on the wiki at http://lhocds.ligo-wa.caltech.edu:8000/40m/Electronics/POY. |
4241
|
Wed Feb 2 15:07:20 2011 |
josephb | Update | CDS | activateDAQ.py now includes PEM channels |
[Joe, Jenne]
We modified the activateDAQ.py script to handle the C1PEM.ini file (defining the PEM channels being recorded by the frame builder) in addition to all the optics channels. Jenne will be modifying it further so as to rename more channels. |
4240
|
Wed Feb 2 12:55:34 2011 |
Koji | Summary | Green Locking | Freq fluctuation measured by the freq divider and Rana's analog PFD |
I found that some flakiness of the beat signals comes from the RF components for the beat detection.
They are touching the racks in an indefinite way. If we move the components the output of the analog PFD
goes crazy.
Once Kiwamu is back I will ask him to clean up all of the green setting in an appropriate way.
|
4239
|
Wed Feb 2 10:44:26 2011 |
Koji | Summary | Green Locking | Freq fluctuation measured by the freq divider and Rana's analog PFD |
The freq fluctuation of the beat note has been measured with the following condition
- The IR beam only locked to the MC. The green beam locked to the arm
- Both of the IR and green locked to the x-arm
Calibration
- The output of the freq divider is already calibrated to have the unit of MHz.
- The transfer function between the analog PFD channel and the digital PFD output was measured to be -23dB = 0.7.
The gain of the XARM-FINE channel was changed to 0.7 such that the output is calibrated in MHz.
Results
- I have not checked the analog noise level of the analog PFD path. We may need more whitening gain (by icreasing the gain of SR560).
- The analog PFD is always better than the digital PFD above 20Hz.
- Both the digital and analog PFD showed good agreement below 20Hz.
Note the measurement was not simultaneous.
- When the arm is locked with the ETMX being actuated , the fluctuation of the arm length must be stabilized by a huge factor
(~10^5 according to Kiwamu's entry) However, we only could see the stabilization factor of 30.
As this residual is the difference of the freq noise felt by the IR and the green,
this is a real issue to be tackled.
- The RMS fluctuations of the arm with and without the IR beam being locked are 2MHz and 0.1MHz,
which correcponds to the arm length motion of 250nm and 13nm, respectively.
Ed: I had to use 532nm in stead of 1064nm. The correct numbers are 130nm and 7nm.
- Without the IR locked, The typical peak-to-peak fluctuation of the beat freq was 10MHz. |
Attachment 1: 110201_green_freq_fluctuation.pdf
|
|
4238
|
Wed Feb 2 09:56:55 2011 |
Koji | Summary | Green Locking | Installed the freq divider and Rana's PFD |
- The freq divider and Rana's PFD were hooked up to the ADCs. (Attachment 1)
(I leave the analog PFD not explained in this entry.)
For this purpose, the VCO feedback signal has been disconnected and the beat signal was moved from the VCO loop to the analog PFD.
The output level of the splitter was +12dBm and was too high for the freq divider.
So, I had to stupidly add an attenuator of 10dB before the box.
- Gain of the digital PFD LPF
The LPF of the digital PFD had the gain of -4096 to let the output signal indicate the direct frequency reading.
The gain has been changed to -67.108864
such that the output shows the direct reading of the beat freq in the unit of MHz
-4096*2^14/10^6 = -67.108864
- Attachment 2 shows the acquired beat note through the freq divider.
The blue is the beat note between "green locked" and "IR locked only to MC" (i.e. MC vs XARM)
The red is the beat note with the both beam locked to the arm
The freq divider is a bit flaky in some freq region as the divided output sometimes shows freq jumps or the captured at a freq.
I still don't know why it happens. We have to check why this happens. |
Attachment 1: freq_divider_installation.pdf
|
|
Attachment 2: 110201_freq_divider_output.pdf
|
|
4237
|
Wed Feb 2 03:27:20 2011 |
Koji | Summary | Green Locking | 85MHz Freq divider |
The freq divider was built and installed in the beat detection path.
Attachment 1: Circuit diagram
- Input stage: Wideband RF amp with DC block at the input and the output. The gain is 10dB typ.
- 2nd stage: Ultra fast comparator AD9696. Note: AD9696 is an obsolete IC and there are only a few extra at Wilson house.
The output is TTL/CMOS compatible.
- 3rd stage: 14bit binary ripple counter (fmax~100MHz.)
Note: I have added 7805/7905 regulators to the circuit as I could not find -5V supply on the 1X1/2 racks.
Attachment 2: Packaging
- The box is german made Eurocard size box from Techno-Isel Linear Motion http://www.techno-isel.com/lmc/Products/EnclosureProfiles11055.htm
The box is excellent but I didn't like the fixing bolts as they are self-tapping type. I tapped the thread and used #6-32 screws.
- The prototyping board is BPS's (BusBoard Prototype System http://www.busboard.us/) SP3UT. The card size is 160mm x 100mm.
The other side is a ground plane and the small holes on the board are through holes to the ground plane.
This particular card was not easy to use.
- The input is SMA. Unfortunately, it is not isolated. The output is an isolated BNC.
- The supply voltage of +/-15V is given by the 3pin D-connector. The supply voltages have been obtained from the cross connect of 1X1.
Attachment 3: Input specification
- The input frequency is 10MHz~85MHz. At lower frequency chattering of the comparator against the multiple zero crossing of the (relatively) slow sinusoidal waves.
- The input amplitude. There are no apparent degradation of the freq jitter when the input power was larger than -30dBm.
|
Attachment 1: freq_divider.pdf
|
|
Attachment 2: IMG_3816.JPG
|
|
Attachment 3: IMG_3818.JPG
|
|
4236
|
Tue Feb 1 17:34:21 2011 |
Jenne | Update | SUS | ETMX and PRM watchdogs tripped |
I sat down in the control room to find that ETMX and PRM's watchdogs had been tripped. I don't know how long they've been crazy, but there was a big something that showed up in the seismometers around 16:30UTC, or ~11:30 this morning. I don't find any significant earthquakes on the USGS site for that time though, so it might be more local, i.e. work next door or trucks or whatever.
I take back the suggestion that it was that seismic event. Clearly the PRM and the ETMX were kicked at different times, neither of which is the same as the seismic action. Mystery. You can see they have been ringing down for a while though, which is neat. |
Attachment 1: Seis_1Feb2011.png
|
|
Attachment 2: Seis_SUS_1Feb2011.png
|
|
4235
|
Tue Feb 1 15:09:41 2011 |
Koji | Omnistructure | General | Projector - fixed |
The projector in the controls room has been fixed the orange blinking of the status LED.
What we needed was to push "Volume -" and "Menu" for 5 sec.
This resets the timer of the lamp. When the timer reaches 2500 hours, it automatically start sabotaging.
We've got the spare lamp. It is in the top drawer of the computer cabinet on which the label makers are. |
4234
|
Mon Jan 31 18:25:25 2011 |
Aidan | Update | Green Locking | DFD - results from the new filters (and running with AWG) |
Quote: |
This is a plot showing the old filters and the new ones we added this morning.
The new ones have a Cheby for AC coupling below 10 Hz and then a 500 Hz LP after the mixer. The LP frequency has been increased so that we can use this signal in a feedback loop to the ETM with a ~100 Hz UGF.
|
Joe injected a 234.567 etc. Hz sine wave into the excitation channel in the DFD INPUT filter. The spectrum of the output of the LP filter with the new filter is shown below with the RMS calculated from 300Hz down to 1mHz - see first attachment. The RMS is equal to about 2.5Hz. (Incidentally, the RMS is very much higher (slightly less than 400Hz - see second attachment) if you calculate it from 7kHz down to 1mHz). |
Attachment 1: DFD-bandwidth_noise_CLP500_to_300Hz.pdf
|
|
Attachment 2: DFD-bandwidth_noise_CLP500_to_7000kHz.pdf
|
|
4233
|
Mon Jan 31 16:12:11 2011 |
steve | Update | VAC | Vertex crane upgrade shorth coming |
The upgrade is almost finished. I found that the passive latch lock is not closing down all the way. It has about a 3/8" gap. See Atm. 1 & 2
The service man was here this morning and agreed to fix it. They will be back next week. The latch needs an other spring to push it into full lock.
We tested all possible sequences of operation of the new upgrade. It performed to specification.
Quote:
|
|
|
Attachment 1: P1070364.JPG
|
|
Attachment 2: P1070358.JPG
|
|
4232
|
Mon Jan 31 12:40:38 2011 |
rana, joe | Update | Green Locking | DFD - medm screen |
This is a plot showing the old filters and the new ones we added this morning.
The new ones have a Cheby for AC coupling below 10 Hz and then a 500 Hz LP after the mixer. The LP frequency has been increased so that we can use this signal in a feedback loop to the ETM with a ~100 Hz UGF. |
Attachment 1: a.pdf
|
|
4231
|
Mon Jan 31 10:31:30 2011 |
josephb | Update | WienerFiltering | Improvement in H1 Wiener FF prediction by using weights and taps |
Rossa is a rather beefy machine. It effectively has 8 Intel i7 Cores (2.67 Ghz each) and 12 Gigs of ram. Megatron only has 8 Gigs of ram and just 8 Opterons (1 GHz each). Rosalba has 4 Quad Core2 (2.4 GHz) with only 4 Gigs of ram.
MC damp |
dataviewer |
diaggui |
AWG |
c1ioo |
c1sus |
c1iscex |
RFM |
The Dolphins |
Sim.Plant |
Frame builder |
TDS |
|
|
|
|
|
|
|
|
|
|
|
|
|
4230
|
Mon Jan 31 07:41:23 2011 |
Aidan | Update | Green Locking | DFD - medm screen |
I added an MEDM screen for the DFD to the GREEN screen. It is displayed in the attached screen shot.
This screen is located in: /cvs/cds/rtcds/caltech/c1/medm/c1gfd/C1GFD_DFD.adl |
Attachment 1: Screenshot-3.png
|
|
4229
|
Mon Jan 31 07:03:59 2011 |
Aidan | Summary | Green Locking | DFD - noise spectra |
Quote: |
I've had a go at trying to estimate the frequency noise of the digital frequency discriminator (DFD). I input a 234.5Hz (0.5Vpp) signal from a 30MHz function generator into the ADC. The LP output of the DFD measured 234.5Hz. However, this signal is clearly modulated by roughly +/- 0.2Hz at harmonics of 234.5Hz (as you can see in the top plot in the dataviewer screenshot below). So the frequency noise can be estimated as rms of approximately 0.2Hz.
This is supported by taking the spectra of the LP output and looking at the RMS. Most of the power in the RMS frequency noise (above the minimum frequency) comes from the harmonics of the input signal and the RMS is approximately 0.2Hz.
I believe this stems from the rather basic LP filter (three or four poles around 10Hz?) that is used in the LP filter to remove the higher frequency components that exist after the mixing stage. (The currently loaded LPF filter is not the same as the saved one in Foton - and that one won't load at the moment, so I'm forced to remember the shape of the current filter).
The attached screen capture from data viewer shows the LP_OUT hovering around 234.5Hz.
|
Here is the spectrum of the input into the DFD (a 234.5Hz sine wave, 0.5 Vpp) and the spectrum and RMS of the LP output. The linewidth of the input signal is clearly much less than 0.1Hz, where as the RMS noise (above 2mHz) is approximately 0.2Hz and the main contributions are clearly the harmonics of the 234.5Hz signal. |
Attachment 1: DFD-bandwidth_noise.pdf
|
|
4228
|
Sun Jan 30 19:26:03 2011 |
Koji | Summary | Green Locking | Prototype freq divider |
A prototype freq divider has been made which works up to ~40MHz.
74HC4060 (14bit binary ripple counter) divides the freq of the input signal, which is comverted by the comparator LT1016
into the rectangular signal. The division rate is 2^14.
Attachment1: Circuit diagram
Attachment2: Photo, the prototype bread board
Attachment3: Photo, the spectrum of the freq divided output. The 40MHz input has been divided into 2.4k.
There are the 3rd and 5th harmonics seen. The peak was pretty sharp but the phase noise was not evaluated yet.
The circuit was made on the prototype bread board which is apparently unsuitable for RF purposes.
Indeed, it was surprising to see its working up to 40MHz...
In order to increase the maximum freq of the system we need the following considerations
- RF PCB board
- Input RF buffer (or amplifier) with a 50Ohm input impedance.
- Faster comparator. LT1016 has the response time of 10ns, which is not enough fast.
- Faster counter. Faster chip 74HC4020 has already been ordered.
|
Attachment 1: freq_divider.pdf
|
|
Attachment 2: IMG_3813.jpg
|
|
Attachment 3: IMG_3814.jpg
|
|
4227
|
Sun Jan 30 17:15:09 2011 |
Aidan | Summary | Green Locking | Digital Frequency discriminator - frequency noise |
I've had a go at trying to estimate the frequency noise of the digital frequency discriminator (DFD). I input a 234.5Hz (0.5Vpp) signal from a 30MHz function generator into the ADC. The LP output of the DFD measured 234.5Hz. However, this signal is clearly modulated by roughly +/- 0.2Hz at harmonics of 234.5Hz (as you can see in the top plot in the dataviewer screenshot below). So the frequency noise can be estimated as rms of approximately 0.2Hz.
This is supported by taking the spectra of the LP output and looking at the RMS. Most of the power in the RMS frequency noise (above the minimum frequency) comes from the harmonics of the input signal and the RMS is approximately 0.2Hz.
I believe this stems from the rather basic LP filter (three or four poles around 10Hz?) that is used in the LP filter to remove the higher frequency components that exist after the mixing stage. (The currently loaded LPF filter is not the same as the saved one in Foton - and that one won't load at the moment, so I'm forced to remember the shape of the current filter).
The attached screen capture from data viewer shows the LP_OUT hovering around 234.5Hz. |
Attachment 1: _Untitled_(modified).png
|
|
4226
|
Sat Jan 29 03:13:44 2011 |
rana | Update | WienerFiltering | Improvement in H1 Wiener FF prediction by using weights and taps |
(Jenne, Rana)
Tonight we noticed that there were significant improvements to be had in the predicted DARM Wiener filtering FF performance by using weighting filters and more taps in the FIR filter.
The plots below tell the story:
The first one shows the improvement in the residual (black & blue) by applying a weighting filter. The weight filter tilts the spectrum up at HF and applies and all real pole BP from 10-20 Hz.
The second plot shows the improvement gotten by using 3000 instead of 2000 taps for the Wiener filter. With the larger number of taps we not only get the big improvement at LF, but also some beefy reduction in the higher frequency stack modes and the LOS roll mode.
I'm not sure why we haven't run across this before; the weighting filter was arrived at today by just iterating by hand on the placement of poles and zeros until the trace looked nice.
Jenne is going to run this new filter on the S5-month that we have been using for stationarity testing.
* Some notes:
** this Wiener stuff is faster, by far, on rossa than either megatron or rosalba or my laptop. More than a factor of 3.
*** there is a bug with Macports/Matlab - if you get fftw3 with Macports, it sets itself as the right version to use. This confuses matlab in some cases.
if you get the error about libfftw3.dylib, whe trying fft in matlab after installing macports, then you can fix it by setting the Matlab lib/ path with the fftw libraries to be ahead of /opt/local/lib in the LD_LIBRARY_PATH in your .cshrc. |
Attachment 1: darmweight.png
|
|
Attachment 2: darm3000.png
|
|
4225
|
Sat Jan 29 00:31:05 2011 |
Suresh | Update | General | Vertex crane upgrade completed |
The Vertex crane is smarter and safer now. This upgrade ensures that the two sections of I-beam (8ft, 4ft) remain firmly latched to form a straight member till the latch is released.
In specific, it ensures that problems such as this one do not occur in the future.
The new safety features are:
When the I-beam sections are latched together, a pneumatic piston ensures that the latch is secure.
If the latch is not engaged the trolley does not move outward beyond the end of the 8-foot section of the I beam.
If the trolley is out on the 4-foot section of the beam then we cannot disengage the latch.
How does it work?

The state of the Limit Switch 1 changes when the trolly goes past it. The Limit Switch 2 gets pressed when the two sections are latched together.
The pneumatic piston raises or lowers the latch. The Pneumatic Latch Switch operates a pneumatic valve controlling the state of the piston.

The new controller now has Pneumatic Latch Switch in addition to the usual Start, Stop, Up, Down, In and Out buttons.
Each of the Up, Down, In and Out buttons have two operational states: Half pressed (low speed) and Full pressed (High Speed). Their functions remain the same as before.
The new Pneumatic Switch:
When this switch is 'Engaged' and the 4 ft section is swung in-line with the 8 ft section, the two sections get latched together.
To unlatch them we have to throw the switch into the 'Disengage' state. This makes the piston push the latch open and a spring rotates the 4 ft section about its pivot.
Limit Switch 2 is not pressed (I-beams not aligned straight) ==> Limit Switch 1 will prevent the trolley from out going beyond the 8 ft section.
While Limit Switch 2 is pressed we cannot disengage the latch.
Note:
The pneumatic piston requires 80psi of pressure to operate. However we have only 40psi in the lab and the piston seems to operate quite well at this pressure as well. I believe a request has been made to get an 80psi line laid just for this application.
|
Attachment 1: Vertex_Crane-2.png
|
|
Attachment 2: Vertex_Crane-4.png
|
|
4224
|
Fri Jan 28 18:19:21 2011 |
Jenne | Update | IOO | WFS2 has some kind of oil on it |
Mystery solved!
I removed WFS2 from the AP table (after placing markers so I can put it back in ~the same place) so that I could take some reflectivity as a function of angle measurements for aLIGO WFS design stuff.
I was dismayed to discover, upon glancing at the diode itself, that half of the diode is covered with some kind of oil!!!. The oil is mostly confined to quadrants 3 and 4, which explains the confusion with their quantum efficiency measurements, as well as why the readback values on the MEDM WFS Head screen for WFS2 don't really make sense.
The WFS QPD has a piece of glass protecting the diode itself, and the oil seems to be on top of the glass, so I'm going to use some lens tissue and clean it off.
Pre-cleaning photos are on Picasa.
Update: I tried scrubbing the glass with a Q-tip soaked with Iso, and then one soaked in methanol. Both of these failed to make any improvement. I am suspicious that perhaps whatever it is, is underneath the glass, but I don't know. Rana suggested replacing the diode, if we have spares / when we order some spares.

Quote: |
Problem with 2 quadrants of WFS2?
While doing all of this, I noticed that quadrants 3 and 4 of WFS2 seem to be different than all the rest. You can see this on the MEDM screens in that all 6 other quadrants, when there is no light, read about -0.2, whereas the 2 funny quadrants read positive values. This might be okay, because they both respond to light, in some kind of proportion to the amount of light on them. I ended up getting QE of ~72% for both of these quadrants, which doesn't make a whole lot of sense since the spec for green is 70%, and silicon is supposed to be less good for infrared than green. Anyhow, we'll have to meditate on this. We should also see if we have a trend, to check how long they have been funny.
|
|
4223
|
Fri Jan 28 15:50:44 2011 |
Jenne | Configuration | PSL | The PSL has a name! |
Back in the days when we were talking about getting a new 2W PSL, I was given naming rights by Rana for this new laser.
Today, the 40m PSL was given its new name: Edwin.
Here he is, with his shiny new label:

|
4222
|
Fri Jan 28 13:07:31 2011 |
Jenne | Update | IOO | Beam is back on the WFS |
The MC WFS have had beam dumps in front of them for the past ~2 weeks, until I could find the appropriate optic to put in the WFS path, to avoid melting the WFS' electronics.
Koji noted that Steve had a W2-45S in a secret stash near his desk (which Steve later had put into the regular optics storage shelves down the Yarm), so I used that in front of the black hole beam dump on the AS table. Now the beam is ~1W reflected from the unlocked mode cleaner, and ~100mW goes to the MC REFL PD. The other 900mW now goes to this W2, and only ~5mW is reflected toward the MC WFS. Most of the 900mW is transmitted through the window and dumped in the black hole. There is a ghost beam which is reflected off the back surface of the wedged window, and I have blocked this beam using a black anodized aluminum dump. I will likely change this to a razor dump if space on the table allows. I have aligned the beam onto WFS1 and WFS2, although I did not re-align the mode cleaner first, so this alignment of the WFS will likely need to be redone.
WFS1 has about 2mW incident, and WFS2 has about 3mW incident, when the mode cleaner is unlocked. I have not yet measured the power incident when the MC is locked, although obviously it will be much smaller.
Except that I might temporarily remove one of the WFS for more quantum efficiency measurements later today, the WFS should be ready to turn back on for alignment stabilization of the mode cleaner.
Quote: |
My goal this afternoon was to measure the quantum efficiency of the MC WFS. In the process of doing this, I discovered that when I reverted a change in the MCWFS path (see elog 4107 re: this change), I had not checked the max power going to the WFS when the MC unlocks.
Current status:
MC locks (is locked now). No light going to WFS at all (to prevent MC WFS french-fry action). Quantum Efficiency measured.
The Full Story:
Power to WFS:
Rana asked me to check out the quantum efficiency of the WFS, so that we can consider using them for aLIGO. This involves measuring the power incident on the PDs, and while doing so, I noticed that WFS1 had ~160mW incident and WFS2 had ~240mW incident while the mode cleaner was unlocked. This is bad, since they should have a max of ~10mW ever. Not that 200mW is going to destroy the PD immediately, but rather the current out, with the 100V bias that the WFS have, is a truckload of power, and the WFS were in fact getting pretty warm to the touch. Not so good, if things start melting / failing due to extended exposure to too much heat.
The reason so much power was going to the WFS is that it looks like Yuta/Koji et. al., when trying to use the WFS as a MC1 oplev, changed out 2 of the beam splitters in the MC WFS / MC Refl path, not just one. Or, we've just been crispy-frying our WFS for a long time. Who knows? If it is option A, then it wasn't elogged. The elog 3878 re: BS changeout only mentions the change of one BS.
Since the MC Refl path has a little more than ~1W of power when the MC is unlocked, and the first BS (which was reverted in elog 4107) is a 10% reflector, so ~100mW goes to the MC Refl PD, and ~900mW goes to the MC WFS path. In front of a Black Hole beam dump was sitting a BS1-33, so we were getting ~300mW reflected to be split between the 2 WFS, and ~600mW dumped. The new plan is to put a W2 window in place of this BS1-33, so that we get hopefully something like 0.1% reflected toward the WFS, and everything else will be dumped. I could not find a W2-45S (everything else is S, so this needs to be S as well). I found a bunch of W2-0deg, and a few W2-45P. Does anyone have a secret stash of W2-45S's??? To avoid any more excessive heat just in case, for tonight, I have just left out this mirror entirely, so the whole MC WFS beam is dumped in the Black Hole. The WFS also have aluminum beam dumps in front of them to prevent light going in. None of this affects the MC Refl path, so the MC can still lock nice and happily.
|
|
4221
|
Fri Jan 28 13:05:56 2011 |
Koji | Configuration | Computers | script path fixed |
We had some issues in terms of the script paths. I have fixed it by replacing /cvs/cds/caltech/scripts to /cvs/cds/rtcds/caltech/c1/scripts
Here is the output of diff
----------------------------------------------
rossa:caltech>diff cshrc.40m cshrc.40m.20110128
44,47c44,45
< # OBSOLETE set path = ($path /cvs/cds/caltech/scripts/general)
< # OBSOLETE set path = ($path /cvs/cds/caltech/scripts/general/netgpibdata)
< set path = ($path /cvs/cds/rtcds/caltech/c1/scripts/general)
< set path = ($path /cvs/cds/rtcds/caltech/c1/scripts/general/netgpibdata)
---
> set path = ($path /cvs/cds/caltech/scripts/general)
> set path = ($path /cvs/cds/caltech/scripts/general/netgpibdata)
50,51c48
< # OBSOLETE setenv PERL5LIB /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/perlmodules:/cvs/cds/caltech/libs/solaris9/usr_local_lib/perl5/5.8.0/:/cvs/cds/rtcds/caltech/c1/scripts/general:/cvs/cds/rtcds/caltech/c1/scripts/general/perlmodules
< setenv PERL5LIB /cvs/cds/caltech/libs/solaris9/usr_local_lib/perl5/5.8.0/:/cvs/cds/rtcds/caltech/c1/scripts/general:/cvs/cds/rtcds/caltech/c1/scripts/general/perlmodules
---
> setenv PERL5LIB /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/perlmodules:/cvs/cds/caltech/libs/solaris9/usr_local_lib/perl5/5.8.0/:/cvs/cds/rtcds/caltech/c1/scripts/general:/cvs/cds/rtcds/caltech/c1/scripts/general/perlmodules
61,64c58,59
< #OBSOLETE setenv PATH ${SOLARISPATH}/bin:$GDSPATH/bin:$ROOTSYS/bin:$TDSPATH/bin:/cvs/cds/caltech/scripts/general/netgpibdata:$PATH
< setenv PATH ${SOLARISPATH}/bin:$GDSPATH/bin:$ROOTSYS/bin:$TDSPATH/bin:/cvs/cds/rtcds/caltech/c1/scripts/general/netgpibdata:$PATH
< #OBSOLETE setenv SCRIPTS /cvs/cds/caltech/scripts
< setenv SCRIPTS /cvs/cds/rtcds/caltech/c1/scripts
---
> setenv PATH ${SOLARISPATH}/bin:$GDSPATH/bin:$ROOTSYS/bin:$TDSPATH/bin:/cvs/cds/caltech/scripts/general/netgpibdata:$PATH
> setenv SCRIPTS /cvs/cds/caltech/scripts
87,88c82
< #OBSOLETE setenv PERL5LIB /cvs/cds/caltech/scripts/general:/cvs/cds/rtcds/caltech/c1/scripts/general/perlmodules
< setenv PERL5LIB /cvs/cds/rtcds/caltech/c1/scripts/general:/cvs/cds/rtcds/caltech/c1/scripts/general/perlmodules
---
> setenv PERL5LIB /cvs/cds/caltech/scripts/general:/cvs/cds/rtcds/caltech/c1/scripts/general/perlmodules
99,100c93
< #OBSOLETE setenv SCRIPTPATH /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/netgpibdata
< setenv SCRIPTPATH /cvs/cds/rtcds/caltech/c1/scripts/general:/cvs/cds/rtcds/caltech/scripts/general/netgpibdata
---
> setenv SCRIPTPATH /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/netgpibdata
103,104c96
< #OBSOLETE setenv SCRIPTS /cvs/cds/caltech/scripts
< setenv SCRIPTS /cvs/cds/rtcds/caltech/c1/scripts
---
> setenv SCRIPTS /cvs/cds/caltech/scripts
135,137c127
< #OBSOLETE alias listenDARM '/cvs/cds/caltech/scripts/c1/listenDARM'
< alias listenDARM '/cvs/cds/rtcds/caltech/c1/scripts/c1/listenDARM'
<
---
> alias listenDARM '/cvs/cds/caltech/scripts/c1/listenDARM'
156,157c146
< #OBSOLETE setenv PERL5LIB /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/perlmodules
< setenv PERL5LIB /cvs/cds/rtcds/caltech/c1/scripts/general:/cvs/cds/rtcds/caltech/c1/scripts/general/perlmodules
---
> setenv PERL5LIB /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/perlmodules
167,168c156
< #OBSOLETE setenv SCRIPTPATH /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/netgpibdata
< setenv SCRIPTPATH /cvs/cds/rtcds/caltech/c1/scripts/general:/cvs/cds/rtcds/caltech/scripts/general/netgpibdata
---
> setenv SCRIPTPATH /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/netgpibdata
172,173c160
< #OBSOLETE setenv SCRIPTS /cvs/cds/caltech/scripts
< setenv SCRIPTS /cvs/cds/rtcds/caltech/c1/scripts
---
> setenv SCRIPTS /cvs/cds/caltech/scripts
198,199c185
< #OBSOLETE alias listenDARM '/cvs/cds/caltech/scripts/c1/listenDARM'
< alias listenDARM '/cvs/cds/rtcds/caltech/c1/scripts/c1/listenDARM'
---
> alias listenDARM '/cvs/cds/caltech/scripts/c1/listenDARM'
288,295c274,277
< #OBSOLETE alias makefiltscreen '/cvs/cds/caltech/scripts/Admin/makeFilterScreen.pl'
< #OBSOLETE alias makelockinscreen '/cvs/cds/caltech/scripts/Admin/makeLockInScreen.pl'
< #OBSOLETE alias f_and_r '/cvs/cds/caltech/scripts/Admin/find_and_replace.pl'
< #OBSOLETE alias plotrgascan '/cvs/cds/caltech/scripts/RGA/plotrgascan'
< alias makefiltscreen '/cvs/cds/rtcds/caltech/c1/scripts/Admin/makeFilterScreen.pl'
< alias makelockinscreen '/cvs/cds/rtcds/caltech/c1/scripts/Admin/makeLockInScreen.pl'
< alias f_and_r '/cvs/cds/rtcds/caltech/c1/scripts/Admin/find_and_replace.pl'
< alias plotrgascan '/cvs/cds/rtcds/caltech/c1/scripts/RGA/plotrgascan'
---
> alias makefiltscreen '/cvs/cds/caltech/scripts/Admin/makeFilterScreen.pl'
> alias makelockinscreen '/cvs/cds/caltech/scripts/Admin/makeLockInScreen.pl'
> alias f_and_r '/cvs/cds/caltech/scripts/Admin/find_and_replace.pl'
> alias plotrgascan '/cvs/cds/caltech/scripts/RGA/plotrgascan'
|
4220
|
Fri Jan 28 12:15:58 2011 |
josephb | Update | CDS | Updating conlog channel list/ working on "HealthCheck" script |
I've updated the scan_adls script (currently located in /cvs/cds/caltech/conlog/bin) to look at new location of our medm screens. I made a backup of the old conlog channel list as /cvs/cds/caltech/conlog/data/conlog_channels.old-2011-01-28.
I then ran the update_chanlist script in the same directory, which calls the scan_adl script. After about 5 minutes it finished updating the channel list. I restarted the conlogger just to be sure, and checked that our new model channels showed up in the conlog (which they do).
I have added a cron job to the op340m cron tab to once a day run the update_conlog script at 7am.
Next, I'm working on a HealthCheck script which looks at the conlog channel list and checks to see if channels are actually changing over short time scales, and then spit back a report on possibly non-functioning channels to the user. |
4219
|
Fri Jan 28 11:08:44 2011 |
josephb | Update | Green Locking | no transmission of ALS signals |
As you've correctly noted, the source of the C1:GCV-SCX_ETMX_ALS channels is in the c1gcv model. The first 3 letters of the channel name indicate this (GCV).
The destination of this channel is c1scx, the 2nd 3 letters indicate this (SCX). If it passed through the c1rfm model, it would be written like C1:GCV-RFM_ETMX_ALS.
This particular channel doesn't pass through the c1rfm model, because the computers these two run on (c1ioo and c1scx) are directly connected via our old VMIC 5565 RFM cards, and don't need to pass through the c1sus computer. This is in contrast to all communications going to or from the c1lsc machine, since that is only connected the c1sus machine by the Dolphin RFM. The c1rfm also handles a bunch of RFM reads from the mode cleaner WFS, since each eats up 3-4 microseconds and I didn't want to slow the c1mcs model by 24 microseconds (and ~50 microseconds before the c1sus/c1scx computer switch).
So basically c1rfm is only used for LSC communications and for some RFM reads for local suspensions on c1sus.
As for the reason we have no transmission, that looks to be a problem on c1ioo's end. I'm also noticing that MCL is not updating on the MC2 suspension screen as well as no changes to MC PIT and YAW channels, which suggests we're not transmitting properly.
I rebooted the c1ioo machine and then did a burt restore of the c1ioo and c1gcv models. These are now up and running, and I'm seeing both MCL and ALS data being transmitted now.
Its possible that when we were working on the c1gfd (green frequency divider model) on c1ioo machine we disturbed the RFM communication somehow. Although what exactly, I'm not sure.
Quote: |
No signal is transmitted from C1:GCV-SCX_ETMX_ALS (on c1gcv) to C1:GCV-SCX_ETMX_ALS (on c1scx)
I can't find RFM definition for ALS channels in c1rfm. Where are they???
|
|
4218
|
Fri Jan 28 10:27:46 2011 |
Aidan, Joe | Summary | Green Locking | Digital Frequency Discriminator - calibration |
One more thing ... we can calibrate the output of the LP filter to give a result in Hz with the following calibration:
LP_OUT = -1/(2*dt)*(LP_IN -1), where dt is 1/16384, the delay time of the delayed path.
Therefore LP_OUT = -8192*(LP_IN-1). |
4217
|
Fri Jan 28 09:03:38 2011 |
Aidan | Summary | Green Locking | Digital Frequency Discriminator |
Quote: |
That's some pretty fast work! I thought we would be taking up to a week to get that happening. I wonder what's the right way to measure the inherent frequency noise of this thing?
Also, should the comparator part have some hysteresis (ala Schmidt trigger) or is it best to just let it twirl as is? Is it sensitive to DC offsets on the input or is there a high pass filter? What's the correct low pass filter to use here so that we can have a low phase lag feedback to the ETM?
|
We could try inputing a 4kHz carrier modulated width a depth of a few Hz at a modulation frequency of F1. Then we could take an FFT of the output of the discriminator and measure the width of the peak at F1 Hz. This seems like an arduous way to measure the frequency noise at a single frequency though.
It'll definitely be sensitive to DC offsets but there is already a filter bank on the INPUT filter so we can shape that as necessary. We could probably band-pass that from [4.5 - 5.3kHz] (which would correspond to a range of [73,87] MHz into a 2^14 frequency divider.
|
4216
|
Thu Jan 27 23:21:50 2011 |
rana | Summary | Green Locking | Digital Frequency Discriminator |
That's some pretty fast work! I thought we would be taking up to a week to get that happening. I wonder what's the right way to measure the inherent frequency noise of this thing?
Also, should the comparator part have some hysteresis (ala Schmidt trigger) or is it best to just let it twirl as is? Is it sensitive to DC offsets on the input or is there a high pass filter? What's the correct low pass filter to use here so that we can have a low phase lag feedback to the ETM? |
4215
|
Thu Jan 27 21:43:37 2011 |
Koji | Update | Green Locking | no transmission of ALS signals |
No signal is transmitted from C1:GCV-SCX_ETMX_ALS (on c1gcv) to C1:GCV-SCX_ETMX_ALS (on c1scx)
I can't find RFM definition for ALS channels in c1rfm. Where are they??? |
4214
|
Thu Jan 27 21:10:47 2011 |
Osamu | Update | 40m Upgrading | Calibrated noise of green |
I calibrated noise spectrum of green lock.
1. Measurement of conversion factor of ADC input from V to ct:
As a preparation, first I measured a conversion factor at ADC input of C1;GCX1SLOW_SERVO1.
It was measured while the output of AI ch6 as the output of C1;GCX1SLOW_SERVO2 with 1Hz, 1000ct(2000ct_pp) was directly connected into AA ch7 as the input of C1;GCX1SLOW_SERVO1. Amplitude at the output at AI ch6 was 616mVpp measured by oscilloscope, and C1;GCX1SLOW_SERVO1_IN1 read as 971.9ct_pp. So the conversion factor is calculated as 6.338e-4[V/ct].
2. Injection of a calibration signal:
When Green laser was locked to cavity with fast PZT and slow thermal, I injected 100Hz, 1000ct EXC at ETMX ASL. The signal was measured at C1:GCX1SLOW_SERVO1_IN1 as 5.314ct_rms. It can be converted into 3.368e-3Vrms using above result, and then converted into 3368Hz_rms using PZT efficiency as 1MHz/V. This efficiency was obtained from Koji's knowledge, but he says that it might have 30% or higher error. If somebody get more accurate value, put it into the conversion process from V to Hz here.
3. Conversion;
Frequency of green f=c/532nm=5.635e14[Hz] is fluctuating with above 3368Hz_rms,so the fluctuation ratio is 3368/5.635=5.977e-12, and it corresponds to length fluctuation of 37.5m. So, cavity fluctuation will be 5.977e-12*37.5=2.241e-10m_rms by 100Hz, 1000ct EXC at ETMX ASL.
4. Results;
Finally, we knew 5.314ct corresponds to 3368Hz and 2.241e-10m, so conversion factor from ct to Hz and ct to m are ;
633.8[Hz/ct] @ C1:GCX1SLOW_SERVO1
4.217e-11[m/ct] @ C1:GCX1SLOW_SERVO1
5. Calibration:
You can measure green noise spectrum at C1;GCX1SLOW_SERVO1_IN1 during lock, and mutiply above result to convert Hz or m.
This calibration is effective above corner frequency of slow and fast servo around 0.5Hz and UGF of fast servo around 4kHz.
I show an example of calibrated green noise.


Each color show different band-width. Of course this results of calibration cactor does not depend on band-width. Noise around 1.2Hz is 6e-8Hz/rHz. It sounds a bit too good by factor ~2. The VCO efficiency might be too small.
Note that there are several assumptions in this calibration;
1. TF from actual PZT voltage to PZT mon is assumed to be 1 in all frequency. Probably this is not a bad assumption because circuit diagram shows monitor point is extracted PZT voltage directly.
2. However above assumption is not correct if the input impedance of AI is low.
3. As I said, PZT efficiency of 1MHz/V might be wrong.
I also measured a TF from C1:SUS-ETMX_ALS_EXC to C1:GCX1SLOW_SERVO1_IN1. It is similar as calibration injection above but for wide frequency. This shows a clear line of f^-2 of suspension.

Files are located in /users/osamu/:20110127_Green_calibration. |
4213
|
Thu Jan 27 17:12:02 2011 |
Aidan, Joe | Summary | Green Locking | Digital Frequency to Amplitude converter |
Joe and I built a very simple digital frequency to amplitude converter using the RCG. The input from an ADC channel goes through a filter bank (INPUT), is rectified and then split in two. One path is delayed by one DAQ cycle (1/16384 s) and then the two paths are multiplied together. Then the output from the mixer goes through a second filter bank (LP) where we can strip off twice the beat frequency. The DC output from the LP filter bank should be proportional to the input frequency.
Input Channel: C1:GFD-INPUT_xxx
Output Channel: C1:GFD-LP_xxx
Joe compiled the code and we tested it by injecting a swept sine [100, 500]Hz in the input filter bank. We confirmed that output of the LP filter bank changed linearly as a function of the input frequency.
The next thing we need to do is add a DAC output. Once that's in place we should inject the output from a 4kHz VCO into the ADC. Then we can measure the transfer function of the loop with an SR785 (driving the VCO input and looking at the output of the DAC) and play around with the LP filter to make sure the loop is fast enough.
The model is to be found here:
/opt/rtcds/caltech/c1/core/advLigoRTS/src/epics/simLink/c1gfd.mdl
The attached figures show the model file in Simulink and a realtime dataviewer session with injecting a swept sine (from 500Hz to 100Hz) into the INPUT EXC channel. We've had some frame builder issues so the excitation was not showing on the green trace and, for some reason, the names of the channels are back to front in dataviewer (WTF?), - the lower red trace in dataviewer is actually displaying C1:GFD-LP_OUT_DAQ, but it says it is displaying C1:GFD-INPUT_OUT_DAQ - which is very screwy.
However, the basic principle (frequency to amplitude) seems to work. |
Attachment 1: Screenshot.png
|
|
Attachment 2: Swept_sine_F_to_A.png
|
|
4212
|
Thu Jan 27 15:16:43 2011 |
josephb | Update | CDS | Updated generate_master_screens.py |
I modified the generate_master_screens.py script in /opt/rtcds/caltech/c1/medm/master/ to handle changing the MCL (and MC_L) listings to ALS for the two ETM suspension screens and associated sub-screens.
The relevant added code is:
custom_optic_channels = ['ETMX',
{'MCL':'ALS','MC_L':'ALS'},
'ETMY',
{'MCL':'ALS','MC_L':'ALS'}]
for index in range(len(custom_optic_channels)/2):
if optic == custom_optic_channels[index*2]:
for swap in custom_optic_channels[index*2+1]:
sed_command = start_sed_string + swap + "/" + custom_optic_channels[index*2+1][swap] + middle_sed_string + optic + file
os.system(sed_command)
When run, it generates the correctly named C1:SUS-ETMX_ALS channels, and replaces MCL and MC_L with ALS in the matrix screens.
|
4211
|
Thu Jan 27 11:04:27 2011 |
Koji | Update | Green Locking | beat freq scan |
Experiment in the night of Jan 26.
o The arm was locked for the IR beam and was aligned for it.
o The green was aligned to the arm
o The beat freq was observed with the RF analyzer and the webcam.
o Engaged the ALS servo
o Compared the fluctuation of the beat freq with and without ALS
o Scanned the beat freq in order to find an IR resonance
The beat freq was scanned. A resonance for IR was found.
However, the residual motion of the arm was not within the line width of the IR resonance.
To Do
- Improve the ALS servo (==>Koji)
- VCO noise characterization (==>Suresh is on it)
- Calibrate the PLL feedback (i.e. ALS error) into Hz/rtHz (==>Suresh)
- Calibrate the end green PZT fb into Hz/rtHz (==>Osamu is on it)
- Tuning of the suspension filters to reduce the bounce mode coupling.
DETAILS
o How to lock the arm with IR
- Coarsely align the arm without lock. Transmittion was ~300 with MCTRANS ~40000
- REFL11I is the error signal. unWhiten filter (FM1) should be on.
- Unlock the MC and null the error and the arm trans offset by running the following commands
ezcaservo -g -0.1 -r C1:LSC-REFL11_I_OUTPUT C1:LSC-REFL11_I_OFFSET
ezcaservo -g -0.1 -r C1:LSC-REFL11_Q_OUTPUT C1:LSC-REFL11_Q_OFFSET
ezcaservo -g 0.1 -r C1:LSC-TRX_OUTPUT C1:LSC-TRX_OFFSET
- Confirm the input matrix to pass REFL11I to MC path (why don't we use XARM path...?)
ezcawrite C1:LSC-MTRX_81 1.0
- Servo configuration
- For acquisition: Gain of 2. Only FM1 (1000:10) has to be on.
- After the acquisition (TRX>200): The gain is to be changed to 1. FM2 and FM3 can be turned on for the LF boost.
- Actuator matrix: connect MC path to ETMX and MC2
ezcawrite C1:LSC-OM_MTRX_18 1.0
ezcawrite C1:LSC-OM_MTRX_78 1.0
o How to align the green beam
- After the alignment I went the end and aligned the last two steering mirrors.
o The beat freq monitor
- Put the RF analyzer at the RF splitter of the RFPD output.
- Used Zonet webcam (http://192.168.113.201:3037) for the remote monitoring
o How to engage the ALS servo
- Preparation:
- VCO PLL feedback comes to X_FINE path.
- Put an offset of -850 to cancel too big offset (when the VCO is unlocked)
- Use Y_FINE channel for the offset addtion. FM1 is 10mHz LPF in order to make the offset smooth.
- Add X_FINE and Y_FINE by the matrix.
- Control
- Turn off X_FINE out. Leave Y_FINE output turned on.
- Turn on ETMX ALS path.
- Servo setting: FM1 1000:30 ON, others OFF, gain1
- Wait for the beat comes in to the locking range at around 80MHz.
- If the peak is too far, sweep Y_FINE offset in order to . Or change GCV slow thermal offset to let the beat freq jump.
- You may have ambiguity of the feedback sign depending on which green has higher freq.
- After the capture of the ALS lock, increse the gain up to 20. Turn on 0.1:boost at FM3.
o Comparison of the stability of the beat freq (Attachment3)
- The spectra of the VCO PLL feedback was measured.
- First of all, the signal was measured without ALS (blue).
The PLL lost lock quite frequently, so the careful adjustment of the offset was necessary.Still I think there was slight saturation upconversion.
- Then, the ALS was turned on (red). The gain was 20. This is an in-loop evaluation of the servo. The suppression was ~1000 at 1Hz.
o Beat freq scanning
- The following command was used for the beat note scanning
ezcastep -- "C1:GCV-YARM_FINE_OFFSET" "5,500"
- Once the IR transmission was found, the scan was stopped.
- Because the resultant rms stability of the arm was not within the line width of the cavity, the smooth resonant curve was not obtained.
- From the shape of the error signal the peak-to-peak displacement (f>1Hz) was estimated to be +/-0.7nm. The dominant displacement
in the period is 16Hz component.
|
Attachment 1: arm_scan.pdf
|
|
Attachment 2: arm_cav_scan3.png
|
|
Attachment 3: 110126_ALS_inloop.pdf
|
|
4210
|
Thu Jan 27 03:24:56 2011 |
Kevin | Update | Electronics | POY Optical Transfer Function |
[Rana and Kevin]
I measured the optical transfer function of POY and fit the data using LISO. The fit can be found at http://lhocds.ligo-wa.caltech.edu:8000/40m/Electronics/POY. POY was missing the RF cage and back cover so I took those parts from AS55 in order to make these measurements.
POY does not have the unwanted oscillations at 225 MHz that POX has. Attachment 1 shows the transfer functions of POX and POY.
To measure the transfer functions, I used a 50/50 beam splitter to send half the light from an AM laser to POY and half the light to a New Focus 1611 reference photodiode. The transfer function for POY was measured as the transfer function of the signal from POY divided by the signal from the 1611. When I was measuring the transfer function for POX, I failed to ensure that the photodiodes were operating linearly. Before making the measurements for POY, I varied the RF power modulating the AM laser and recorded the magnitude of the transfer function at the 11 MHz peak. Attachment 2 shows these values. The measurements for POY were made in the linear region at an RF power of -10 dBm. The measurements for POX were made at 0 dBm and were most likely not in the linear region for POX. |
Attachment 1: tf_pox_poy.png
|
|
Attachment 2: linearity.png
|
|
4209
|
Wed Jan 26 14:49:48 2011 |
Aidan | Update | Environment | Turned on Control room AC |
80 degrees is too uncomfortable in the control room so I turned on the AC. The set point is 74F. |
4208
|
Wed Jan 26 12:04:31 2011 |
josephb | Update | CDS | Explanation of why c1sus and c1lsc models crash when the other one goes down |
So apparently with the current Dolphin drivers, when one of the nodes goes down (say c1lsc), it causes all the other nodes to freeze for up to 20 seconds.
This 20 seconds can force a model to go over the 60 microseconds limit and is sufficiently long enough to force the FE to time out. Alex and Rolf have been working with the vendors to get this problem fixed, as having all your front ends go down because you rebooted a single computer is bad.
[40184.120912] c1rfm: sync error my=0x3a6b2d5d00000000 remote=0x0
[40184.120914] c1rfm: sync error my=0x3a6b2d5d00000000 remote=0x0
[44472.627831] c1pem: ADC TIMEOUT 0 7718 38 7782
[44472.627835] c1mcs: ADC TIMEOUT 0 7718 38 7782
[44472.627849] c1sus: ADC TIMEOUT 0 7718 38 7782
[44472.644677] c1rfm: cycle 1945 time 17872; adcWait 15; write1 0; write2 0; longest write2 0
[44472.644682] c1x02: cycle 7782 time 17849; adcWait 12; write1 0; write2 0; longest write2 0
[44472.646898] c1rfm: ADC TIMEOUT 0 8133 5 7941
The solution for the moment is to start the computers at exactly the same time, so the dolphin is up before the front ends, or start the models by hand after the computer is up and dolphin running, but after they have timed out. This is done by:
sudo rmmod c1SYSfe
sudo insmod /opt/rtcds/caltech/c1/target/c1SYS/bin/c1SYSfe.ko
Alex and Rolf have been working with the vendors to get this fixed, and we may simply need to update our Dolphin drivers. I'm trying to get in contact with them and see if this is the case. |
4207
|
Wed Jan 26 12:03:45 2011 |
Koji | Update | CDS | Front End multiple crash |
This is definitely a nice magic to know as the rebooting causes too much hustles.
Also, you and I should spend an hour in the afternoon to add the suspension swtches to the burt requests.
Quote: |
I killed the dead c1lsc model by typing:
sudo rmmod c1lscfe
I then tried starting just the front end model again by going to the /opt/rtcds/caltech/c1/target/c1lsc/bin/ directory and typing:
sudo insmod c1lscfe.ko
This started up just the FE again
|
|
4206
|
Wed Jan 26 10:58:48 2011 |
josephb | Update | CDS | Front End multiple crash |
Looking at dmesg on c1lsc, it looks like the model is starting, but then eventually times out due to a long ADC wait.
[ 114.778001] c1lsc: cycle 45 time 23368; adcWait 14; write1 0; write2 0; longest write2 0
[ 114.779001] c1lsc: ADC TIMEOUT 0 1717 53 181
I'm not sure what caused the time out, although there about 20 messages indicating a failed time stamp read from c1sus (its sending TRX information to c1lsc via the dolphin connection) before the time out.
Not seeing any other obvious error messages, I killed the dead c1lsc model by typing:
sudo rmmod c1lscfe
I then tried starting just the front end model again by going to the /opt/rtcds/caltech/c1/target/c1lsc/bin/ directory and typing:
sudo insmod c1lscfe.ko
This started up just the FE again (I didn't use the restart script because the EPICs processes were running fine since we had non-white channels). At the moment, c1lsc is now running and I see green lights and 0x0 for FB0 status on the C1LSC_GDS_TP screen.
At this point I'm not sure what caused the timeout. I'll be adding some more trouble shooting steps to the wiki though. Also, c1scx, c1scy are probably in need of restart to get them properly sync'd to the framebuilder.
I did a quick test on dataviewer and can see LSC channels such as C1:LSC-TRX_IN1, as well other channels on C1SUS such as BS sensors channels.
Quote: |
STATUS:
- Rebooted c1lsc and c1sus. Restarted fb many times.
- c1sus seems working.
- All of the suspensions are damped / Xarm is locked by the green
- Thermal control for the green is working
- c1lsc is frozen
- FB status: c1lsc 0x4000, c1scx/c1scy 0x2bad
- dataviewer not working
|
|
4205
|
Wed Jan 26 10:11:47 2011 |
Aidan | Update | Green Locking | cavity scan |
Quote: |

|
Whether or not it's as clean as we'd like, it's really nice to see this result with real data. |
4204
|
Wed Jan 26 02:18:12 2011 |
Koji | Update | SUS | ETMX length to angle matrix |
I have put an offset of 1000 counts to C1:SUS-ETMX_ALS_OFFSET. This actually misalign the mirror a lot.
While the offset is applied. I adjusted the balance of the coil matrix.
UL 1.580 UR 0.620
LL 0.420 LR 1.380
> ezcaread C1:SUS-ETMX_TO_COIL_0_0_GAIN
C1:SUS-ETMX_TO_COIL_0_0_GAIN = 1.58
> ezcaread C1:SUS-ETMX_TO_COIL_0_1_GAIN
C1:SUS-ETMX_TO_COIL_0_1_GAIN = 0.62
> ezcaread C1:SUS-ETMX_TO_COIL_0_2_GAIN
C1:SUS-ETMX_TO_COIL_0_2_GAIN = 0.42
> ezcaread C1:SUS-ETMX_TO_COIL_0_3_GAIN
C1:SUS-ETMX_TO_COIL_0_3_GAIN = 1.38
Now, we can keep TEM00 for green with +/-1000counts of push although the fast step of the offset make the lock lost.
It turned out that the step longitudinal input temporary misalign the mirror in pitch because the length and pitch are coupled.
I guess that we don't excite pitch if we push the mirror slowly. Eventually, we need f2p transfer function adjusted in the output matrix.
Kiwamu told us that: |
(2) Length to Alignment coupling. Pushing ETMX causes a misalignment. |
|