  2197   Fri Nov 6 18:13:34 2009 josephbUpdateComputersMegatron woes

I have removed the RFM card from Megatron and left it (along with all the other cables and electronics) on the trolly in front of the 1Y9 rack.

Megatron proceeded to boot normally up until it started loading Centos 5.  During the linux boot process it checks the file systems.  At this point we have an error:

 

/dev/VolGroup00/LogVol00 contains a file system with errors, check forced

Error reading block 28901403 (Attempt to read block from filesystem resulted short read) while doing inode scan.

/dev/VolGroup00/LogVol00 Unexpected Inconsistency; RUN fsck MANUALLY

 

So I ran fsck manually, to see if I get some more information.  fsck reports back it can't read block 28901403 (due to a short read), and asks if you want to ignore(y)?.  I ignore (by hitting space), and unfortunately touch it an additional time.  The next question it asks is force rewrite(y)?  So I apparently forced a rewrite of that block.  On further ignores (but no forced rewrites) I continue seeing short read errors at 28901404, *40, *41,*71, *512, *513, etc.  So not totally continugous.  Each iteration takes about 5-10 seconds.  At this point I reboot, but the same problem happens again, although it starts 28901404 instead of 28901403.  So apparently the force re-write fixed something, but I don't know if this is the best way of going about this.  I just wondering if there's any other tricks I can try before I just start rewriting random blocks on the hard drive.  I also don't know how widespread this problem is and how long it might take to complete (if its a large swath of the hard drive and its take 10 seconds for each block that wrong, it might take a while).

So for the moment, megatron is not functional.  Hopefully I can get some advice from Alex on Monday (or from anyone else who wants to chime in).  It may wind up being easiest to just wipe the drive and re-install real time linux, but I'm no expert at that.

 

  2264   Fri Nov 13 09:47:18 2009 josephbUpdateComputersMegatron status lights lit

Megatron's top fan, rear ps, and temperature front panel lights were all lit amber this morning.  I checked the service manual, found at :

http://docs.sun.com/app/docs/prod/sf.x4600m2?l=en&a=view

According to the manual, this means a front fan failed, a voltage event occured, and we hit a high temperature threshold.  However, there were no failure light on any of the individual front fans (which should have been the case given the front panel fan light).  The lights remained on after I shutdown megatron.  After unplugging, waiting 30 seconds, and replugging the power cords in, the lights went off and stayed off.  Megatron seems to come up fine.

I unplugged the IO chassis from megatron, rebooted, and tried to start Peter's plant model.  However, it still prints that its starting, but really doesn't.  One thing I forgot to mention in the previous elog on the matter, is that on the local monitor it prints "shm_open(): No such file or directory" every time we try to start one of these programs.

  2265   Fri Nov 13 09:54:14 2009 josephbConfigurationComputersMegatron switched to tcsh

I've changed megatron's controls account default shell to tcsh (like it was before).  It now sources cshrc.40m in /cvs/cds/caltech/ correctly at login, so all the usual aliases and programs work without doing any extra work.

  2273   Mon Nov 16 15:13:25 2009 josephbUpdateComputersezcaread updated to Yoichi style ezcawrite

In order to get the gige camera code running robustly here at the 40m, I created a "Yoichi style" ezcaread, which is now the default, while the original ezcaread is located in ezcaread.bin.  This tries 5 times before failing out of a read attempt.

  2275   Mon Nov 16 15:58:02 2009 josephbConfigurationGeneralAdded Gige camera to AP table, added some screens

I placed a GC750 gige camera looking at a pickoff of the AS port, basically next to the analog camera, on the AP table.

I've modified the main sitemap to include a CAM button, for the digital cameras.  There's a half done screen associated with it.  At the moment, it reports on the X and Y center of mass calculation, the exposure setting, and displays a little graph with a dot indicating the COM of mass location.  Currently this screen is associated a GC750 camera looking at pickoff of the AS port.  I'm having some issues with getting shell scripts to run from it, as well as a slider having limits other than 0 and 0.

  2276   Mon Nov 16 17:24:28 2009 josephbConfigurationComputersCamera medm functionality improved

Currently the Camera medm screen (now available from the sitemap), includes a server and client script buttons.  The server has two options.  One which starts a server, the second which (for the moment) kills all copies of the server running on Ottavia.  The client button simply starts a video screen with the camera image.  The slider on this screen changes the exposure level.  The snap shot button saves a jpeg image in the /cvs/cds/caltech/cam/c1asport directory with a date and time stamp on it (up to the second).  For the moment, these buttons only work on Linux machines.

All channels were added to C0EDCU.ini, and should be being recorded for long term viewing.

Feel free to play around with it, break it, and let me know how it works (or doesn't).

  2279   Tue Nov 17 10:09:57 2009 josephbUpdateEnvironmentFumes

The smell of diesel is particularly bad this morning.  Its concentrated enough to be causing me a headache.  I'm heading off to Millikan and will be working remotely on Megatron.

  2299   Thu Nov 19 09:55:41 2009 josephbUpdateComputersTrying to get testpoints on megatron

This is a continuation from last night, where Peter, Koji, and I were trying to get test point channels working on megatron and with the TST module.

Things we noticed last night:

We could run starttst, and ./daqd -c daqdrc, which allowed us to get some channels in dataviewer.  The default 1k channel selection works, but none of the testpoints do. 

However, awgtpman -s tst does appear in the processes running list.

The error we get from dataviewer is:

Server error 861: unable to create thread
Server error 23328: unknown error
datasrv: DataWriteRealtime failed: daq_send: Illegal seek

Going to DTT, it starts with no errors in this configuration.  Initially it listed both MDC and TST channels.  However, as a test, I moved the tpchn_C4.par , tpchn_M4.par and tpchn_M5.par files to the directory backup, in /cvs/cds/caltech/target/gds/param.  This caused only the TST channels to show up (which is what we want when not running the mdc module.

We had changed the daqdrc file in /cvs/cds/caltech/target/fb, several times to get to this state.  According to the directions in the RCG manual written by Rolf, we're supposed to "set cit_40m=1" in the daqdrc file, but it was commented out.  However, when we uncommented it, it started causing errors on dtt startup, so we put it back.  We also tried adding lines:

set dcu_rate 13 = 16384;
set dcu_rate 14 = 16384;

But this didn't seem to help.  The reason we did this is we noticed dcuid = 13 and dcuid = 14 in the /cvs/cds/caltech/target/gds/param/tpchn_C1.par file.  We also edited the testpoint.par file so that it correctly corresponded to the tst module, and not the mdc and mdp modules.  We basically set:

[C-node1]
hostname=192.168.1.2
system=tst

in that file, and commented everything else out.

At this point, given all the things we've changed, I'm going to try a rebuild of the tst and daq and see if that solves things.

 

  2300   Thu Nov 19 10:19:04 2009 josephbUpdateComputersMegatron tst status

I did a full make clean and make uninstall-daq-tst, then rebuilt it.  I copied a good version of filters to C1TST.txt in /cvs/cds/caltech/chans/ as well as a good copy of screens to /cvs/cds/caltech/medm/c1/tst/.

Test points still appear to be broken.  Although for a single measurement in dtt, I was somehow able to start, although the output in the results page didn't seem to have any actual data in the plots, so I'm not sure what happened there - after that it just said unable to select test points.  It now says that when starting up as well.  The tst channels are the only ones showing up.  However, the 1k channels seem to have disappeared from Data Viewer, and now only 16k channels are selectable, but they don't actually work.  I'm not actually sure where the 1k channels were coming from earlier now that I think about it.  They were listed like C1:TST-ETMY-SENSOR_UL and so forth.

RA: Koji and I added the SENSOR channels by hand to the .ini file last night so that we could have data stored in the frames ala c1susvme1, etc.

  2301   Thu Nov 19 11:33:15 2009 josephbConfigurationComputersMegatron

I tried rebooting megatron, to see if that might help, but everything still acts the same. 

I tried using daqconfig and changed channels from deactiveated to activated.  I learned by activating them all, that the daq can't handle that, and eventually aborts from an assert checking a buffer size being too small.  I also tried activating 2 and looking at those channels, and it looks like the _DAQ versions of those channels work, or at least I get 0's out of C1:TST-ETMY_ASCPIT_OUT_DAQ (which is set in C1TST.ini file).

I've added the SENSOR channels back to the /csv/cds/caltech/chans/daq/C1TST.ini file, and those are again working in data viewer.

At this point, I'm leaving megatron roughly in the same state as last night, and am going to wait on a response from Alex.

  2371   Wed Dec 9 10:53:41 2009 josephbUpdateCamerasCamera client wasn't able to talk to server on port 5010, reboot fixed it.

I finally got around to taking a look at the digital camera setup today.  Rob had complained the client had stopped working on Rosalba.

After looking at the code start up and not complain, yet not produce any window output, it looks like it was a network problem.  I tried rebooting Rosalba, but that didn't fix anything.

Using netstat -an, I looked for the port 5010 on both rosalba and ottavia, since that is the port that was being used by the camera.  Ottavia was saying there were 6 established connections after Rosalba had rebooted (rosalba is 131.215.113.103).  I can only presume 6 instances of the camera code had somehow shutdown in such a way they had not closed the connection.

[root@ottavia controls]#netstat -an | grep 5010
tcp        0      0 0.0.0.0:5010                0.0.0.0:*                   LISTEN     
tcp        0      0 131.215.113.97:5010         131.215.113.103:57366       ESTABLISHED
tcp        0      0 131.215.113.97:5010         131.215.113.103:58417       ESTABLISHED
tcp        1      0 131.215.113.97:46459        131.215.113.97:5010         CLOSE_WAIT 
tcp        0      0 131.215.113.97:5010         131.215.113.103:57211       ESTABLISHED
tcp        0      0 131.215.113.97:5010         131.215.113.103:57300       ESTABLISHED
tcp        0      0 131.215.113.97:5010         131.215.113.103:57299       ESTABLISHED
tcp        0      0 131.215.113.97:5010         131.215.113.103:57315       ESTABLISHED

 

I switched the code to use port 5022 which worked fine.  However, I'm not sure what would have caused the original connection closure failures, as I test several close methods (including the kill command on the server end used by the medm screen), and none seemed to generate this broken connection state.  I rebooted Ottavia, and this seemed to fix the connections, and allowed port 5010 to work.  I also tried creating 10 connections, which all seem to run fine simultaneously.  So its not someone overloading that port with too many connections which caused the problem.  Its like the the port stopped working somehow, which froze the connection status, but how or why I don't know at this point.

  2509   Tue Jan 12 11:34:26 2010 josephbUpdatePEMAllegra dataviewer

Quote:

So that we can use both Guralps for Adaptive stuff, and so that I can look at the differential ground motion spectra, I've reconnected the Guralp Seismometers to the PEM ADCU, instead of where they've been sitting for a while connected to the ASS ADC.  I redid the ASS.mdl file, so that the PEM and PEMIIR matricies know where to look for the Gur2 data.  I followed the 'make ass' procedure in the wiki.  The spectra of the Gur1 and Gur2 seismometers look pretty much the same, so everything should be all good.

There's a problem with DataViewer though:  After selecting signals to plot, whenever I hit the "Start" button for the realtime plots, DataViewer closes abruptly. 

When I open dataviewer in terminal, I get the following output:

allegra:~>dataviewer
Warning: communication protocol revision mismatch: expected 11.3, received 11.4
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: communication protocol revision mismatch: expected 11.3, received 11.4
msgget: No space left on device
allegra:~>framer4 msgget:msqid: No space left on device

Does anyone have any inspiration for why this is, or what the story is?  I have GR class, but I'll try to follow up later this afternoon.

 This problem seems to be restricted to allegra.  Dataviewer works fine on Rosalba  and op440m, as well as using ssh -X into rosalba to run dataviewer remotely.  DTT seems to work fine on allegra.  The disk usage seems no where near full on allegra.  Without knowing which "device" its refering to (although it must be a device local to allegra), I'm not sure what to look at now. 

I'm going to do a reboot of allegra and see if that helps.

Update:  The reboot seems to have fixed the issue.

 

 

 

 

  2514   Thu Jan 14 11:44:06 2010 josephbSummaryComputersMemory locations for TST model for ITMY

The main communications data structure is RFM_FE_COMMS, from the rts/src/include/iscNetDsc40m.h file.  The following comments regard sub-structures inside it.  I'm looking at all the files in /rts/src/fe/40m to determine how the structures are used, or if they seem to be unnecessary.

The dsccompad structure is used in the lscextra.c file.  I am assuming I don't need to add anything fo the model for these.  They cover from 0x00000040 to 0x00001000.

FE_COMMS_DATA is used twice, once for dataESX (0x00001000 to 0x00002000), and once for dataESY (0x00002000 to 0x00003000).

Inside FE_COMMS_DATA we have:

status and cycle which look to be initialized then never changed (although they are compared to).

ascETMoutput[P,Y], ascQPDinput are all set to 0 then never used.

qpdGain is used, and set by asc40m, but not read by anything.  It is offset 114, so in dataESX its 4210 (0x00001072), and in dataESY its (0x00002072)

All the other parts of this substructure seem to be unused.

daqTest, dgsSet, low1megpad,mscomms seem unused.

dscPad is referenced, but doesn't seem to be set.

pCoilDriver is a structure of type ALL_CD_INFO, inside a union called suscomms, inside FE_COMMS_Data, and is used.  In this structure, we have:

extData[16], an array of DSC_CD_PPY structures, which is used.  Inside extData we have for each optic (ETMY has an offset of 9 inside the extData array):

Pos is set in sos40m.c via the line pRfm->suscomms.pCoilDriver.extData[jj].Pos = dsp[jj].data[FLT_SUSPos].filterInput;   Elsewhere, Pos seems to be set to 1.0

Similarly, Pit and Yaw are set in sos40m, except with FLT_SUSPitch and FLT_SUSYaw, and being set elsewhere to 1.1, 1.2.  However, these are never applied to the ETMX and ETMY optics (it goes through offests 0 through 7 inclusive). 

Side is set 1.3 or 1.0 only, not used.

ascPit , ascYaw, lscPos are read by the losLinux.c code, and is updated by the sos40m.c code. For ETMY, their respective addresses are: 0x11a1c0, 0x11a1c4, 0x11a1c8.

lscTpNum, lscExNum, seem to be initialized, and read by the losLinux.c, and set by sos40m.c.

modeSwitch is read, but looks to be used for turning dewhitening on and off. Similarly dewhiteSW1R is read and used. 

This ends the DSC_CD_PPY structure.

lscCycle, which is used, although it seems to be an internal check.

dum is unused.

losOpLev is a substructure that is mostly unused.  Inside losOpLev, opPerror, opYerror, opYout seem to be unused, and opPout only seems ever to be set to 0.

Thats the end of ALL_CD_INFO and pCoilDriver.

After we have itmepics, itmfmdata, itmcoeffs, rmbsepics,...etymyepics, etmyfmdata,etmycoeffs which I don't see in use.

We have substructure asc inside mcasc, with epics, filt, and coeff char arrays. These seem to be asc and iowfsDrv specific.

lscIpc, lscepics, and lscla seems lsc specific,

The there is lscdiag struct, which contains v struct, which includes cpuClock, vmeReset, nSpob, nPtrx, nPtry don't seem to be used by the losLinux.c.

The lscfilt structure contains the FILT_MOD dspVME, which seems to be used only by lsc40m.

The lsccoeff structure contrains the VME_COEF pRfmCoeff, which again seems to only interact in the lsc code.

Then we have aciscpad, ascisc, ascipc, ascinfo, and mscepics which do not seem to be used.

ascepics and asccoeff are used in asc.c, but does not seem to be referenced elsewhere.

hepiepics , hepidsp, hepicoeff, hepists do not appear to be used.

 

 

 

 

 

 

  2515   Fri Jan 15 11:21:05 2010 josephbUpdateComputersMegatron and tst model for ETMY

The tst model wasn't compiling this morning due to some incorrect lines in the RfmIOfloat.pm file located in /home/controls/cds/advLIgo/src/epics/util/lib file on megatron. 

The error was "Undefined subroutine &CDS::RfmIOfloat::partType called at lib/Parser2.pm line 354, <IN> line 3363."

I changed RfmIO to RfmIOfloat on lines 1 and 6.
Basically the first 6 lines are now

package CDS::RfmIOfloat;
use Exporter;
@ISA = ('Exporter');

sub partType {
        return RfmIOfloat;
}

The tst now compiles.  At the moment, I believe we should be able to switch megatron in for ETMY and attempt to lock the arm.  The whitening/dewhitening filters are still not automatically synced in software and hardware, but I don't think that should prevent locking.

  2530   Tue Jan 19 10:30:29 2010 josephbUpdateComputersBoot fest to restart the computer and c1iscey not responding.

Quote:

Thi afternoon I found that the RFM network in trouble. The frontends sync counters had railed to 16384 counts and some of the computers were not responding. I went for a bootfest, but before I rebooted c1dcu epics. I did it twice. Eventually it worked and I could get the frontends back to green.

Although trying to burtrestore to snapshots taken at any time after last wednesday till today would make the RFM crash again. Weird.

Also, c1iscey seems in a coma and doesn't want to come back. Power cycling it didn't work. I don't know how to be more persuasive with it.

During the testing of Megatron as the controller for ETMY, c1iscey had been disconnected from the ethernet hub.  Apparently we forgot to reconnect it after the test.  This prevented it from mounting the nfs directory from linux1, and thus prevented it from coming up after being shutdown.  It has been reconnected, restarted, and is working properly now.

  2544   Mon Jan 25 11:42:24 2010 josephbUpdateComputersMegatron and BO board

I was talking with Vladimir on Friday discussing the Binary Output board, we looked at the manual for it (Contec DO-32L-PE) and we realized its an opto-coupler isolated open-collector output.  He mentioned they had the right kind of 50 channel breakout board for testing in Riccardo's lab.

This morning I borrowed the 50 channel breakout board from Riccardo's lab, and along with some resistor loads, test the BO board.  It seems to be working, and I can control the output channel on/off state.

  2558   Tue Feb 2 10:38:30 2010 josephbUpdateComputersMegatron BO test

Last night, I connected megatron's BO board to the analog dewhitening board.  However, I was unable to lock the y arm (although once I disconnected the cable and reconnected it back the xy220 the yarm did lock).

So either A) I've got the wrong cable, or B) I've got the wrong logic being sent to the analog dewhitening filters.

During testing, I ran into an odd continuous on/off cycle on one of the side filer modules (on megatron).  Turns out I had forgotten to use a ground input to the control filer bank (which allows you to both set switches as well as read them out), and it was reading a random variable.  Grounding it in the model fixed the problem (after re-making).

 

 

  2570   Thu Feb 4 12:29:04 2010 josephbUpdateComputersMartian IP switch over notes

What is the change:

We will be moving the 131.215.113.XXX ip addresses of the martian network over to a 192.168.XXX.YYY scheme.

What will users notice:

Computer names (i.e. linux1, scipe25/c1dcuepics) will not change.  The domain name martian, will not change (i.e. linux1.martian.).  What will change is the underlying IP address associated with the host names.  Linux1 will no longer be 131.215.113.20 but something like 192.168.0.20.  If everything is done properly, that should be it.  There should be no impact or need to change anything in EPICS for example.  However, if there are custom scripts with hard coded IP addresses rather than hostnames, those would need to be updated, if they exist.

What needs to be done:

Each computer and router will need to either be accessed remotely, or directly, and the configuration files controlling the IP address (and/or dns lookup locations) be modified.  Then it needs to be rebooted so the configuration changes take effect. I'll be making an updated list of computers this week (tracked down via their physical ethernet cables), and next week, probably on Thursday, and then we simply go down the list one by one.

LINUX

For a linux machine, this means checking the /etc/hosts file and making sure it doesn't have old information.  It should look like:

127.0.0.1               localhost.localdomain localhost
::1             localhost6.localdomain6 localhost6

Then change the /etc/sysconfig/network-scripts/ifcfg-eth0 file (or ethX file depending on the ethernet card in question).  The IPADDR, NETWORK, and GATEWAY lines will need to be changed.  You can change the hostname (although I don't plan on it) by modifying the /etc/sysconfig/network file.

The /etc/resolv.conf file will need to be updated with the new DNS server location (i.e. 131.215.113.20 to 192.168.0.20 for example).

SOLARIS

Simlarly to linux, the /etc/hosts file will need to be updated and/or simplified.  The /etc/defaultrouter file will need to be updated to the new router ip.  /etc/defaultdomain will need to be updated.  The /etc/resolv.conf will need to be updated with the new dns server.

vxWorks

Looking at the vxWorks machines, the command bootChange can be used to view or edit the IP configuration.

The following is an example from c1iscey.

-> bootChange

'.' = clear field;  '-' = go to previous field;  ^D = quit

boot device          : eeE0
processor number     : 0
host name            : linux1
file name            : /cvs/cds/vw/pIII_7751/vxWorks
inet on ethernet (e) : 131.215.113.79:ffffff00
inet on backplane (b):
host inet (h)        : 131.215.113.20
gateway inet (g)     :
user (u)             : controls
ftp password (pw) (blank = use rsh):
flags (f)            : 0x0
target name (tn)     : c1iscey
startup script (s)   :
other (o)            :

value = 0 = 0x0

By updating the the host (name of machine where its mounting /cvs/cds from - i.e. linux1), inet on ethernet (the IP of c1iscey) and host inet (linux1's ip address), we should be able to change all the vxWorks machines.

LINUX1

The DNS server running on linux1 will need to be updated with the new IPs and domain information.  The host file on linux1 will also need to be updated for all the new IP addresses as well.

This will need to be handled carefully as the last time I tried getting away without the host file on linux1, it broke NFS mounting from other machines.  However, as long as the host on linux1 is kept in sync with the dns server files everything should work.

  2580   Mon Feb 8 17:00:36 2010 josephbUpdateComputersMegatron ETMY model updated (tst.mdl)

I've added the control logic for the outputs going to the Contec Digital Output board.  This includes outputs from the QPD filters (2 filters per quadrant, 8 in total), as well as outputs going to the coil input sensor whitening.

At this point, the ETMY controls should have everything the end station FE normally does.  I'm hoping to do some testing tomorrow afternoon with this with a fully locked IFO.

  2583   Tue Feb 9 17:18:45 2010 josephbSummaryComputersLocking Y arm successful with fully replaced front-end for ITMY

We were able to lock the Y-arm using Megatron and the RCG generated code, with nothing connected to c1iscey.

All relevant cables were disconnected from c1iscey and plugged into the approriate I/O ports, including the digital output.  Turns out the logic for the digital output is opposite what I expected and added XOR bitwise operators in the tst.mdl model just before it went out to DO board.  Once that was added, the Y arm locked within 10 seconds or so.  (Compared to the previous 30 minutes trying to figure out why it wouldn't lock).

  2594   Fri Feb 12 11:44:11 2010 josephbUpdateComputersStatus of the IP change over

Quote:

After Joe left:

  1. Turned on op440m and returned him his keyboard and mouse.
  2. Damped MC2.
  3. Opened PSL shutter - locked PMC, FSS,
  4. Started StripTool displays on op540m.
  5. op340m doesn't respond to ping from anyone.
  6. started FSS  SLOW and RCPID scripts on op540 - need to kill and restart on op430m.
  7. ASS wouldn't come up - it doesn't know who linux1 is.
  8. MC autolocker wouldn't run on op540m because of a perl module issue, started it on op440m - it needs to be killed and restarted on op430m.
  9. probably mafalda, linux2, and op430m need some attention - they are all in the same rack.

As of 7:18 PM, the MC is locked and the PSL seems normal + all suspensions are damped and the ELOG is back up as well as the SVN.

5) op340m has had its hosts table and other network files updated.  I also removed its outdated hosts.deny file which was causing some issues with ssh.

6) On op340m I started FSSSlowServo, with "nohup ./FSSSlowServo", after killing it on op540m.

I also kill RCthermalPID.pl, and started with "nohup ./RCthermalPID.pl" on op540m.

7) c1ass is fixed now.  There was a typo in the resolv.conf file (namerserver -> nameserver) which has been fixed.  It is now using the DNS server running on linux1 for all its host name needs.

8) I killed the autlockMCmain40m process running on op440m, modified the script to run on op340m, logged into op340m, went to /cvs/cds/caltech/scripts/MC and ran nohup ./autolockMCmain40m

9) Linux2 does not look like it has not been connected for awhile and its wasn't connected when we started the IP change over yesterday.  Is it supposed to still be in use?  If so, I can hook it up fairly easily.  op340m, as noted earlier, has been switched over.  Mafalda has been switched over.

10) c0rga has now been switched over. 

11) aldabella, the vacuum laptop has had its starting environment variables tweaked (in the /home/controls/.cshrc file) so that it looks on the 192.168.113 network instead of the 131.215.113.  This should mean Steve will not have any more trouble starting up his vacuum control screen.

12) Ottavia has been switched over.

13) At this time, only the GPIB devices and a few laptops remain to get switched over.

  2595   Fri Feb 12 11:56:02 2010 josephbUpdateComputersNodus slow ssh fixed

Koji pointed out that logging into Nodus was being abnormally slow.  I tracked it down to the fact we had forgotten to update the address for the DNS server running on linux1 in the resolv.conf file on nodus.  Basically it was looking for a DNS server which didn't exit, and thus was timing out before going to the next one.  SSHing into nodus should be more responsive.

  2597   Fri Feb 12 13:56:16 2010 josephbUpdateComputersFinishing touches on IP switch over

The GPIB interfaces have been updated to the new 192.168.113.xxx addresses, with Alberto's help.

Spare ethernet cables have been moved into a cabinet halfway down the x-arm.

The illuminators have a white V error on the alarm handler, but I'm not sure why.  I can turn them on and off using the video screen controls (except for the x arm, which has no computer control, just walk out and turn it on).

There's a laptop or two I haven't tracked down yet, but that should be it on IPs. 

At some point, a find and replace on 131.215.xxx.yyy addresses to 192.168.xxx.yyy should be done on the wiki.  I also need to generate an up to date ethernet IP spreadsheet and post it to the wiki.

 

  2599   Fri Feb 12 15:59:16 2010 josephbUpdateComputersTestpoints not working

Non-testpoint channels seem to be working in data viewer, however testpoints are not.  The tpman process is not running on fb40m.  My rudimentary attempts to start it have failed. 

# /usr/controls/tpman &
13929
# VMIC RFM 5565 (0) found, mapped at 0x2868c90
VMIC RFM 5579 (1) found, mapped at 0x2868c90
Could not open 5565 reflective memory in /dev/daqd-rfm1
16 kHz system
Spawn testpoint manager
no test point service registered
Test point manager startup failed; -1

It looks like it may be an issue with the reflected memory (although the cables are plugged in and I see the correct lights lit on the RFM card in back of fb40m.)

The fact that this is a RFM error is confirmed by /usr/install/rfm2g_solaris/vmipci/sw-rfm2g-abc-005/util/diag/rfm2g_util and entering 3 (which should be the device number).

Interestingly, the device number 4 works, and appears to be the correct RFM network (i.e. changing ETMY lscPos offset changes to the corresponding value in memory).

So, my theory is that when Alex put the cards back in, the device number (PCI slot location?) was changed, and now the tpman code doesn't know where to look for it.

Edit: Doesn't look like PCI slot location is it, given there's 4 slots and its in #3 currently (or 2 I suppose, depending on which way you count).  Neither seems much the number 4.  So I don't know how that device number gets set.

 

 

  2610   Wed Feb 17 12:45:19 2010 josephbUpdateComputersUpdated Megatron and its firewall

I updated the IP address on the Cisco Linksys wireless N router, which we're using to keep megatron separated from the rest of the network.  I then went in and updated megatrons resolv.conf and host files.  It is now possible to ssh into megatron again from the control machines.

  2622   Mon Feb 22 09:45:34 2010 josephbUpdateGeneralPrep for Power Supply Stop

Quote:

Autoburts have not been working since the network changeover last Thursday.

Last snapshot was around noon on Feb 11...  


It turns out this happened when the IP address got switched from 131.... to 192.... Here's the horrible little piece of perl code which was failing:

$command = "/usr/sbin/ifconfig -a > $temp";
   system($command);

   open(TEMP,$temp) || die "Cannot open file $temp\n";
   $site = "undefined";
   #                                                                                                     
   # this is a horrible way to determine site location                                                   
   while ($line = <TEMP>) {
     if ($line =~ /10\.1\./) {
       $site = "lho";
     } elsif ($line =~ /10\.100\./) {
       $site = "llo";
     } elsif ($line =~ /192\.168\./) {
       $site = "40m";
     }
   }
   if ($site eq "undefined") {
     die "Cannot Determine Which LIGO Observatory this is\n";

I've now put in the correct numbers for the 40m...and its now working as before. I also re-remembered how the autoburt works:

1) op340m has a line in its crontab to run /cvs/cds/caltech/burt/autoburt/burt.cron (I've changed this to now run at 7 minutes after the hour instead of at the start of the hour).

2) burt.cron runs /cvs/cds/scripts/autoburt.pl (it was using a perl from 1999 to run this - I've now changed it to use the perl 5.8 from 2002 which was already in the path).

3) autoburt.pl looks through every directory in 'target' and tries to do a burt of its .req file.

Oh, and it looks like Joe has fixed the bug where only op440m could ssh into op340m by editing the host.allow or host.deny file (+1 point for Joe).

But he forgot to elog it (-1 point for Joe).®

I knew there was going to be a script somewhere with a hard coded IP address.  My fault for missing it.  However, in regards to the removal of op340m's host.deny file, I did elog it here.  Item number 5.

  2626   Mon Feb 22 11:46:55 2010 josephbUpdateComputersfb40m

I fixed the JetStor 416S raid array IP address by plugging in my laptop to its ethernet port, setting my IP to be on the same subnet, and using the web interface.  (After finally tracking down the password, it has been placed in the usual place).

After this change, I powered up the fb40m2 machine and reboot the fb40m machine. This seems to have made all the associated lights green.

Data viewer is working such that is recording from the point I fixed the JetStor raid array and did the fb40m reboot.  It also can go back in time before the IP switch over.

  2628   Mon Feb 22 13:08:27 2010 josephbUpdateComputersMinor tweaks to c1omc

While working on c1omc, I created a .cshrc file in the controls home directory, and had it source the cshrc.40m file so that useful shortcuts like "target" and "c" work, among other things.  I also fixed the resolv.conf file so that it correctly uses linux1 as its name server (speeding up ssh login times).

  2727   Mon Mar 29 10:40:59 2010 josephbUpdateCamerasGigE camera no work from screen

Quote:

Not that this is an urgent concern, just a data point which shows that it doesn't just not work at the sites.

I had to restart the dhcpd server on Ottavia that allows us to talk to the camera.  I then also changed the configuration script on the camera so that it no longer thinks ottavia is 131.215.113.97, but correctly 192.168.113.97.  Overall took 5 minutes.

I also looked up services for Centos 5, and set it using the program serviceconf to start the DHCP server  when Ottavia is rebooted now.  That should head off future problems of that nature.  For reference, to start the dhcp server manually, become root and type "service dhcpd start".

 

  2734   Tue Mar 30 11:16:05 2010 josephbHowToComputersezca update information (CDS SVN)

I'd like to try installing an updated multi-threaded ezca extension later this week, allowing for 64-bit builds of GDS ezca tools, provided by Keith Thorne.  The code can be found in the LDAS CVS under gds, as well as in CDS subversion repository, located at 

https://redoubt.ligo-wa.caltech.edu/websvn/

Its under gds/epics/ in that repository.  The directions are fairly simple:

1) to install ezca with mult-threading in an existing EPICS installation
-copy ezca_2010mt.tar.gz (EPICS_DIR)/extensions/src
-cd (EPICS_DIR)/extensions/src
-tar -C -xzf ezca_2010mt
-modify (EPICS_DIR)/extensions/Makefile to point 'ezca' at 'ezca_2010mt'
-cd ezca_2010mt
-set EPICS_HOST_ARCH appropriately
-make


 

 

  2739   Wed Mar 31 10:34:02 2010 josephbUpdateelogElog not responding this morning

When I went to use the elog this morning, it wasn't responding.  I killed the process on nodus, and then restarted, per the 40m wiki instructions.

  2744   Wed Mar 31 16:55:05 2010 josephbUpdateComputers2 computers from Alex and Rolf brought to 40m

I went over to Downs today and was able to secure two 8 core machines, along with mounting rails.  These are very thin looking 1U chassis computers. I was told by Rolf the big black box computers might be done tomorrow afternoon.  Alex also kept one of the 8 core machines since he needed to replace a hard drive on it, and also wanted to keep for some further testing, although he didn't specify how long.

I also put in a request with Alex and Rolf for the RCG system to produce code which includes memory location hooks for plant models automatically, along with a switch to flip from the real to simulated inputs/outputs.

 

  2791   Mon Apr 12 17:37:52 2010 josephbUpdateComputersY end simulated plant progress

Currently, the y end plant is yep.mdl.  In order to compile it properly (for the moment at least) requires running the normal makefile, then commenting out the line in the makefile which does the parsing of the mdl, and rerunning after modifying the /cds/advLigo/src/fe/yep/yep.c file.

The modifications to the yep.c file are to change the six lines that look like:

"plant_mux[0] = plant_gndx"  into lines that look like "plant_mux[0] = plant_delayx".  You also have to add initialization of the plant_delayx type variables to zero in the if(feInt) section, near where plant_gndx is set to zero.

This is necessary to get the position feedback within the plant model to work properly.

 

#NOTE by Koji

CAUTION:
This entry means that Makefile was modified not to parse the mdl file.
This affects making any of the models on megatron.

Attachment 1: YEP.png
YEP.png
Attachment 2: YEP_PLANT.png
YEP_PLANT.png
  2798   Tue Apr 13 12:49:35 2010 josephbUpdateComputersY end simulated plant progress

Quote:

Currently, the y end plant is yep.mdl.  In order to compile it properly (for the moment at least) requires running the normal makefile, then commenting out the line in the makefile which does the parsing of the mdl, and rerunning after modifying the /cds/advLigo/src/fe/yep/yep.c file.

The modifications to the yep.c file are to change the six lines that look like:

"plant_mux[0] = plant_gndx"  into lines that look like "plant_mux[0] = plant_delayx".  You also have to add initialization of the plant_delayx type variables to zero in the if(feInt) section, near where plant_gndx is set to zero.

This is necessary to get the position feedback within the plant model to work properly.

 

#NOTE by Koji

CAUTION:
This entry means that Makefile was modified not to parse the mdl file.
This affects making any of the models on megatron.

 To prevent this confusion in the future, at Koji's suggestion I've created a Makefile.no_parse_mdl in /home/controls/cds/advLIGO on megatron.  The normal makefile is the original one (with correct parsing now).  So the correct procedure is:

1) "make yep"

2) Modify yep.c code

3) "make -f Makefile.no_parse_mdl yep"

  2808   Mon Apr 19 13:23:03 2010 josephbConfigurationComputersyum update fixed on control room machines

I went to Ottavia, and tried running yum update.  It was having dependancy issues with mjpegtools, which was a rpmforge provided package.  In order to get it to update, I moved the rpmforge priority above (a lower number) that of epel ( epel -> 20 from 10, rpmforge -> 10 to 20).  This resolved the problem and the updates proceeded (all 434 of them). yum update on Ottavia now reports nothing needs to be done.

I went to Rosalba and found rpmfusion repositories enabled.  The only one of the 3 repositories in each file enabled was the first one.

I then added priority listing to all the repositories on Rosalba.  I set CentOS-Base and related to priority=1.  I set CentOS-Media.repo priority to 1 (although it is disabled - just to head off future problems). I set all epel related to priorities to 20. I set all rpmforge related priorities to 10.  I set all rpmfusion related priorities to 30, and left the first repo in rpmfusion-free-updates and rpmfusion-nonfree-updates were enabled.  All other rpmfusion testing repositories were disabled by me.

I then had to by hand downgrade expat to expat-1.95.8-8.3.el5_4.2.x86_64 (the rpmforge version).  I also removed and reinstalled x264.x86_64.  Lastly I removed and reinstalled lyx. yum update was then run and completed successfully.

I installed yum-priorities on Allegra and made all CentOS-Base repositories priority 1. I similarly made the still disabled CentOS-Media priority 1.  I made all epel related repos priority 20.  I made all lscsoft repos priority=50 (not sure why its on Allegra and none of the other ones).  I made all rpmforge priorities 10.  I then ran "yum update" which updated 416 packages.

 

So basically all the Centos control room machines are now using the following order for repositories:

CentOS-Base > rpmforge > epel > (rpmfusion - rosalba only) > lscsoft (allegra only)

I'm not sure if rpmfusion and lscsoft are necessary, but I've left them for now.  This should mean "yum update" will have far fewer problems in the future.

 

  2824   Wed Apr 21 11:32:31 2010 josephbUpdateCDS40m CDS hardware update and software requests

This is mostly a reminder to myself about what I discussed with Jay and Alex this morning.

The big black IO chassis are "almost" done.  Except for the missing parts.  We have 2 Dolphin, 1 Large and 1 Small I/O Chassis due to us.  One Dolphin is effectively done and is sitting in the test stand.  However, 2 are missing timing boards, and 3 are missing the boards necessary for the connection to the computer.  The parts were ordered a long time ago, but its possible they were "sucked to one of the sites" by Rolf (remember this is according to Jay).  They need to either track them down in Downs (possibly they're floating around and were just confused by the recent move), get them sent back from the sites, or order new ones (I was told by one person that the place they order from them notoriously takes a long time, sometimes up to 6 weeks.  I don't know if this is exaggeration or not...).  Other than the missing parts, they still need to wire up the fans and install new momentary power switches (apparently the Dolphin boards want momentary on/off buttons).  Otherwise, they're done.

We are due another CPU, just need to figure out which one it was in the test stand.

6 more BIO boards are done.  When I went over the plans with Jay, we realized we needed 7 more, not 6, so they're putting another one together.  Some ADC/DAC interface boards are done.  I promised to do another count here, to determine how many we have, how many we need, and then report that back to Jay before I steal the ones which are complete.  Unfortunately, he did not have a new drawing for the ASC/vertex wiring, so we don't have a solid count of stuff needed for them.  I'll be taking a look at the old drawings and also looking at what we physically have.

I did get Jay to place the new LSC wiring diagram into the DCC (which apparently the old one never was put in or we simply couldn't find it).  Its located at: https://dcc.ligo.org/cgi-bin/private/DocDB/ShowDocument?docid=10985

I talked briefly with Alex, reminded him of feature requests and added a new one:

1) Single part representing a matrix of filter banks

2) Automatic generation of Simulated shared memory locations and an overall on/off switch for ADC/DACs

3) Individual excitation and test point pieces (as opposed to having to use a full filter bank).  He says these already exist, so when I do the CVS checkout, I'll see if they work.

 

I also asked where the adl default files lived, and he pointed me at ~/cds/advLigo/src/epics/util/

In that directory are FILTER.adl, GDS_TP.adl, MONITOR.adl.  Those are the templates.  We also discovered the timing signal at some point was changed from something like SYS-DCU_ID to FEC-DCU_ID, so I basically just need to modify the .adl files to fix the time stamp channel as well.  I basically need to do a CVS checkout, put the fixes in, then commit back to the CVS.  Hopefully I can do that sometime today.

I also brought over 9 Contec DO-32L-PE boards, which are PCIe isolated digital output boards which do into the IO chassis.  These have been placed above the 2 new computers, behind the 1Y6 rack.

 

  2826   Wed Apr 21 16:48:38 2010 josephbUpdateCDSHardware update

Alberto and myself went to downs and acquired the 3rd 4x processor (Dual core, so 8x cores total) computer.  We also retrieved 6 BIO interface boards (blue front thin boxes), 4 DAC interface boards, and 1 ADC interface boards.  The tops have not been put on yet, but we have the tops and a set of screws for them.  For the moment, these things have been placed behind the 1Y6 rack and under the table behind the 1Y5 rack

.irwin.jpg

The 6 BIO boards have LIGO travelers associated with them: SN LIGO-S1000217 through SN LIGO-S1000222.

  2832   Thu Apr 22 15:44:34 2010 josephbUpdateComputers 

I updated the default FILTER.adl file located in /home/controls/cds/advLigo/src/epics/util/ on megatron.  I moved the yellow ! button up slightly, and fixed the time string in the upper right.

Attachment 1: New_example_CDS_filter.png
New_example_CDS_filter.png
  2841   Mon Apr 26 10:21:45 2010 josephbUpdateLSCStarted dev of LSC FE

Quote:

Joe and I started working on the new LSC FE control today. We made a diagram of the system in Simulink, but were unable to compile it.

Joe checked out the latest CDS software out of their new SVN and put it somewhere (perhaps his home directory).

The SVN checkout was done on megatron.  It is located under /home/controls/cds/advLigoRTS

So, to compile (or at least try to) you need to copy the .mdl file from /cvs/cds/caltech/cds/advLigo/src/epics/simLink to /home/controls/cds/advLigoRTS/src/epics/simLink on megatron, then run make SYS in the advLigoRTS directory on megatron.

The old checkout from CVS exists on megatron under /home/controls/cds/advLigo.

  2844   Mon Apr 26 11:29:37 2010 josephbUpdateComputersUpdated bitwise.pm in RCG SVN plus other fixes

To fix a problem one of the models was having, I checked the CVS version of the Bitwise.pm file into the SVN (located in /home/controls/cds/advLigoRTS/src/epics/util/lib), which adds left and right bit shifting funtionality.  The yec model now builds with the SVN checkout.

Also while trying to get things to work, I discovered the cdsRfmIO piece (used to read and write to the RFM card) now only accepts 8 bit offsets.  This means we're going to have to change virtually all of the RFM memory locations for the various channels, rather than using the values from its previous incarnation, since most were 4 bit numbers.  It also means it going to eat up roughly twice as much space, as far as I can tell.

Turns out the problem we were having getting to compile was nicely answered by Koji's elog post.  The shmem_daq value was not set to be equal to 1.  This caused it to look for myrimnet header files which did not exist, and caused compile time errors.  The model now compiles on megatron.

[Edit by KA: 4 bit and 8 bit would mean "bytes". I don't recall which e-log of mine Joe is referring.]

 

  2845   Mon Apr 26 12:24:58 2010 josephbUpdateGeneralDaily Downs update

Talked with Jay briefly this morning.

We are due another 1-U 4 core (8 CPU) machine, which is one of the ones currently in the test stand.  I'm hoping sometime this week I can convince Alex to help me remove it from said test stand.

The megatron machine we have is definitely going to be used in the 40m upgrade (to answer a question of Rana's from last Wednesday's meeting).  Thats apparently the only machine of that class we get, so moving it to the vertex for use as the LSC or SUS vertex machine may make sense.  Overall we'll have the ASS, OMC, Megatron (SUS?), along with the new 4 1-U machines, for LSC, IO, End Y and End X.  We are getting 4 more IO chassis, for a total 5.  ASS and OMC machine will be going without full new chassis.

Speaking of IO chassis, they are still being worked on.  Still need a few cards put in and some wiring work done.  I also didn't see any other adapter boards finished either.

  2849   Tue Apr 27 11:16:13 2010 josephbConfigurationCDSWiki page with CDS .mdl names, shared memory allocation

I've added a new page in the wiki which describes the current naming scheme for the .mdl model files used for the real time code generator.  Note, that these model names do not necessarily have to be the names of the channels contained within.  Its still possible to make all suspension related channels start with C1:SUS- for example.  I'm also allocating 1024 8 byte channels for shared memory address space for each controller and each simulated plant.

The wiki page is here

Name suggestions, other front end models that are needed long term (HEPI is listed for example, even though we don't have it here, since in the long run we'd like to port the simulated plant work to the sites) are all welcome.

  2860   Thu Apr 29 14:37:16 2010 josephbUpdateCDSNew Channel Name to Memory Location file

Awhile back we had requested a feature for the RCG code where a single file would define a memory location's name as well as its explicit hex address.  Alex told me it had been implemented in the latest code in SVN.  After being unable to find said file, I went back and talked to him and Rolf.  Rolf said it existed, but had not been checked into the SVN yet. 

I now have a copy of that file, called G1.ipc.  It is supposed to live in /cvs/cds/caltech/chans/ipc/ , so I created the ipc directory there.  The G1.ipc file is actually for a geo install, so we'll eventually make a C1.ipc file.

The first couple lines look like:

# /cvs/cds/geo/chans/ipc/G1.ipc
[default]
ipcType=SHMEM
ipcRate=2048
ipcNum=0
desc=default entry

[G1:OMC-QPD1P]
ipcType=SHMEM
ipcRate=32768
ipcNum=0
desc=Replaces 0x2000
#[G1:OMC-NOTUSED]
#ipcType=SHMEM
#ipcRate=32768
#ipcNum=1

[G1:OMC-QPD2P]
ipcType=SHMEM
ipcRate=32768
ipcNum=1
desc=Replaces 0x2008

 

There are also section using ipcType IPC:

[G1:SUS-ADC_CH_24]
ipcType=PCI
ipcRate=16384
ipcNum=1
desc=Replaces 0x20F0
[G1:SUS-ADC_CH_25]
ipcType=PCI
ipcRate=16384
ipcNum=2
desc=Replaces 0x20F0

 

Effectively the ipcNum tells it which memory location to use, starting with 0x2000 (at least thats how I'm interpreting it.  Every entry of a given ipcType has a different ipcNum which seems to be correlated to its description (at least early on - later in the file many desc= lines repeat, which I think means people were copy/pasting and got tired of editing the file.  Once I get a C1.ipc file going, it should make our .mdl files much more understandable, at least for communicating between models.  It also looks like it somehow interacts with the ADCs/DACs with ipcType PCI, although I'm hoping to get a full intro how to use the file tomorrow from Rolf and Alex.

  2861   Thu Apr 29 15:48:47 2010 josephbUpdateCDSNew CDS overview diagram in wiki

I've added a diagram in the wiki under IFO Upgrade 2009-2010->New CDS->Diagram section Joe_CDS_Plan.pdf (the .svg file I used to create it is also there).  This was mostly an exercise in me learning inkscape as well as putting out a diagram with which lists control and model names and where they're running.

A direct link is: CDS_Plan.pdf

  2871   Mon May 3 15:39:39 2010 josephbUpdateCDSDaily Downs update

Talked with Jay briefly today.  Apparently there are 3 IO chassis currently on the test stand at Downs and undergoing testing (or at least they were when Alex and Rolf were around).  They are being tested to determine which slots refer to which ADC, among other things. Apparently the numbering scheme isn't as simple as 0 on the left, and going 1,2,3,4, etc.  As Rolf and Alex are away this week, it is unlikely we'll get them before their return date.

Two other chassis (which apparently is one more than the last time I talked with Jay), are still missing cards for communicating between the computer and the IO chassis, although Gary thinks I may have taken them with me in a box.  I've done a look of all the CDS stuff I know of here at the 40m and have not seen the cards.  I'll be checking in with him tomorrow to figure out when (and if) I have the the cards needed.

  2872   Mon May 3 16:53:27 2010 josephbUpdateCDSUpdated lsc.mdl and the ifo plant model with memory locations

I've updated the LSC and IFO models that Rana created with new shared memory locations.  I've used the C1:IFO- for the ifo.mdl file outputs, which in turn are read by the lsc.mdl file.  The LSC outputs being lsc control signals are using C1:LSC-.  Optics positions would presumably be coming from the associated suspension model, and am currently using SUP, SPX, and SPY for the suspension plant models (suspension vertex, suspension x end, suspension y end).

I've updated the web view of these models on nodus.  They can be viewed at: https://nodus.ligo.caltech.edu:30889/FE/

I've also created a C1.ipc file in /cvs/cds/caltech/chans/ipc  which assigns ipcNum to each of these new channels in shared memory.

  2877   Tue May 4 13:14:43 2010 josephbUpdateCDSlsc.mdl and ifo.mdl to build (with caveats)

I got around to actually try building the LSC and IFO models on megatron.  Turns out "ifo" can't be used as a model name and breaks when trying to build it.  Has something to do with the find and replace routines I have a feeling (ifo is used for the C1, H1, etc type replacements throughout the code).  If you change the model name to something like ifa, it builds fine though.  This does mean we need a new name for the ifo model.

Also learned the model likes to have the cdsIPCx memory locations terminated on the inputs if its being used in a input role (I.e. its bringing the channel into the model).  However when the same part is being used in an output role (i.e. its transmitting from the model to some other model), if you terminate the output side, it gives errors when you try to make.

Its using the C1.ipc file (in /cvs/cds/caltech/chans/ipc/) just fine.  If you have missing memory locations in the C1.ipc file (i.e. you forgot to define something) it gives a readable error message at compile time, which is good.  The file seems to be being parsed properly, so the era of writing "0x20fc" for block names is officially over.

  2878   Tue May 4 14:57:53 2010 josephbUpdateComputersOttavia has moved

Ottavia was moved this afternoon from the control room into the lab, adjacent to Mafalda in 1Y3 on the top shelf.  It has been connected to the camera hub, as well as the normal network.  Its cables are clearly labeled.  Note the camera hub cable should be plugged into the lower ethernet port. Brief tests indicate everything is connected and it can talk to the control room machines.

The space where Ottavia used to be is now temporarily available as a good place to setup a laptop, as there is keyboard, mouse, and an extra monitor available.  Hopefully this space may be filled in with a new workstation in the near future.

  2895   Fri May 7 14:51:04 2010 josephbUpdateCDSWorking on meta .mdl file scripts

I'm currently working on a set of scripts which will be able to parse a "template" mdl file, replacing certain key words, with other key words, and save it to a new .mdl file.

For example  you pass it the "template" file of scx.mdl file (suspension controller ETMX), and the keyword ETMX, followed by an output list of scy.mdl ETMY,  bs.mdl BS, itmx.mdl  ITMX, itmy.mdl ITMY, prm.mdl PRM, srm.mdl SRM.  It produces these new files, with the keyword replaced, and a few other minor tweaks to get the new file to work (gds_node, specific_cpu, etc).  You can then do a couple of copy paste actions to produce a combined sus.mdl file with all the BS, ITM, PRM, SRM controls (there might be a way to handle this better so it automatically merges into a single file, but I'd have to do something fancy with the positioning of the modules - something to look into).

I also have plans for a script which gets passed a mdl file, and updates the C1.ipc file, by adding any new channels and incrementing the ipcNum appropriately.  So when you make a change you want to propagate to all the suspensions, you run the two scripts, and have an already up to date copy of memory locations - no additional typing required.

Similar scripts could be written for the DAQ screens as well, so as to have all the suspension screens look the same after changing one set.

  2903   Mon May 10 17:47:16 2010 josephbSummaryCDSFinished

So I finished writing a script which takes an .ipc file (the one which defines channel names and numbers for use with the RCG code generator),  parses it, checks for duplicate channel names and ipcNums, and then parses and .mdl file looking for channel names, and outputs a new .ipc file with all the new channels added (without modifying existing channels). 

The script is written in python, and for the moment can be found in /home/controls/advLigoRTS/src/epics/simLink/parse_mdl.py

I still need to add all the nice command line interface stuff, but the basic core works.   And already found an error in my previous .ipc file, where I used the channel number 21 twice, apparently.

Right now its hard coded to read in C1.ipc and spy.mdl, and outputs to H1.ipc, but I should have that fixed tonight.