ID |
Date |
Author |
Type |
Category |
Subject |
2434
|
Sun Dec 20 21:39:40 2009 |
rana, jenne, kiwamu | Update | ASS | OAF Model update and build instructions |
After a lot of headache, I got the OAF working again - read on for details.....................
Sometime last week, Jenne, Kiwamu, and I tried to update the OAF model to include the IIR "feed-around" path.
This path is in parallel to the existing FIR-based adaptive FXLMS stuff that Matt put in earlier. The reason for the
new path is that we want to try emulating the same FF technology which has been successful lately at LLO.
However, we were unable to make the ASS work after this work. Mostly, the build stuff worked fine, but we couldn't get DTT
to make a transfer function. The excitation channels could be selected and the excitation would actually start and get all the
way into MC1, but DTT would just hang on the first swep-sine measurement with no time-out error. Clearly our ASS building
documentation is no good. We tried using the instructions that Koji gave us for AAA, but that didn't completely work.
In particular, the 'make-uninstall-daq-ass' command gave this command:
[controls@c1ass advLigo]$ make uninstall-daq-ass
grep: target/assepics/assepics*.cmd: No such file or directory
Please make ass first
make: *** [uninstall-daq-ass] Error 1
re-arranging the order to do 'make-ass' first fixes this issue and so I have fixed this in the OAF Wiki.
The there's the whole issue with the tpchn_C3.par file. This contains all the test point definitions for the ASS/OAF machine. The main
IFO numbers are all in tpchn_C1.par and the OMC is all in tpchn_C2.par. When we do the usual build, in the 'make install-daq-ass' part:
[controls@c1ass advLigo]$ make install-daq-ass
Installing GDS node 3 configuration file
/cvs/cds/caltech/target/gds/param/tpchn_C3.par
Updating DAQ configuration file
/cvs/cds/caltech/chans/daq/C1ASS.ini
we get this .par file installed in the target area. The ACTUAL param file seems to actually be in /cvs/cds/caltech/gds/param !!
Of course, it still doesn't work. That's because the standard build likes to point to /cvs/cds/caltech/gds/bin/awgtpman and the one that runs on
linux is actually /opt/gds/awgtpman. So I've now made a file called startup_ass.cmd.good which runs the correct one. However, the default build
will try to start the wrong one and we have to fix the 'startass' script to point to the correct one on each build. Running the correct awgtpman
allows us to get the TP data using tools like tdsdata, so far no luck with DTT.\
UPDATE (23:33): It turns out that it was my old nemesis, NTPD. c1ass had a /etc/ntp.conf file that was pointing at an ntp server called rana113. I
am not an NTP server; I don't even know what time it is. I have fixed the ntp.conf file by making it the same ass c1omc (it now points to nodus). After
this I set the date and time manually (sudo date -s "20 DEC 2009 23:27:45" ) and then restarted NTPD. It should now be fine even when
we reboot c1ass.
After all of this nonsense, I am able to get TP data from c1ass and take transfer functions between it and the rest of the world ! |
2435
|
Sun Dec 20 23:42:44 2009 |
Jenne | Update | IOO | New Input Mode Matching Telescope |
I've got most of the new Mode Matching Telescope figured out. The scripts and an example result are at: MMT09 wiki (Rather, the scripts are in the svn: MMT svn)
Issues still to be resolved:
* We're getting pretty iffy 'angles' between tilt and translation when using the mode matching mirrors for steering.
* I haven't taken into account the astigmatism which occurs when you tilt the mode matching mirrors.
The nifty thing about these scripts is that they take a look at the mode matching overlap: For each possible mode matching solution it adds noise to all of the distances and radii of curvature during ~10,000 iterations and plots a histogram of the overlap so that we can see which solutions have a better chance of giving us the optimal overlap, even if we place the optics in slightly the wrong place.
I'd like to update the overlap part of the script with the astigmatism business: do we lose goodness of overlap if we tilt the mirrors by a bit? I think this will require redoing the overlap part with the X and Y directions separate. Koji has done this in the past. My current code assumes that the beam is always symmetric in X and Y. |
2437
|
Mon Dec 21 02:22:31 2009 |
rana, jenne, kiwamu | Update | ASS | OAF Model update and build instructions |
This allowed measuring the MC1 -> MCL TF finally. Its mostly flat. Data saved as Templates/OAF/OAF-MCLTF.xml |
Attachment 1: Untitled.png
|
|
2438
|
Mon Dec 21 07:30:58 2009 |
??? | Update | ASS | OAF Model update and build instructions |
What does OAF stand for? The entry doesn't say that. Also the acronym is not in the abbreviation page of the wiki.
Can anyone please explain that? |
2440
|
Mon Dec 21 10:09:06 2009 |
jenne | Update | ASS | OAF Model update and build instructions |
OAF stands for Online Adaptive Filtering. We use the same computer which was once the ASS. One of these days, we'd like to completely be rid of all things which refer to ASS, and make even the computer's name OAF. |
2441
|
Mon Dec 21 19:24:29 2009 |
rana | Update | ASS | OAF Model update and build instructions |
I fit the MC1 -> MCL TF using vectfit4.m (from mDV). The wrapper file is mDV/extra/C1/ fitMC12MCL.m .
Plotted here are the data (RED), the fit (BLUE), and the residual x10 (GREEN).
For the magnitude plot, residual is defined as ------ res = 1 - fit / data
For the phase plot the residual is defined as ------- res = phase(data)-phase(fit)
You can see that the agreement is very good. The phase match is better than 5 deg everywhere below 10 Hz.
This TF is so smooth that we could have probably done without using this, but its good to excercise the method anyway. |
Attachment 1: mc12mcl.png
|
|
2442
|
Tue Dec 22 02:50:09 2009 |
rana, kiwamu, jenne | Update | ASS | OAF Feedaround ON and doing something good |
Kiwamu made the OAF screen functional today - screenshot attached.
After this, I used the measured TF of the MC1 to MCL to filter the signals from the Wilcoxon accelerometers and feed them into the MC.
The noise at 3 Hz went down by a factor of ~3. There's a little excess created at 100 Hz. Its good to see that our intuition about feed-forward is OK.
I did all of the filter calculations by adapting the scripts that Haixing, Valera, and I got going at LLO. They're all in the mDV/extra/C1 SVN.
The Wiener code predicts much better performance from using more than just 2 horizontal accelerometers, but I was too lazy to do more channels today.
I also added the Rai box to the Ranger readout today - the noise at 0.1 Hz went down by a factor of 10 and the noise at 1 Hz is close to 10^-11 m/rHz. |
Attachment 1: oaf.png
|
|
Attachment 2: oaf.png
|
|
2444
|
Tue Dec 22 11:23:51 2009 |
kiwamu, Steve | Update | IOO | MC relocked |
In this morning I found MC unlocked.
Steve restored the watchdogs before I found that.
Then I relocked MC and now MC is locked and working well.
The reflected DC power is ~0.38, which is usual number.
|
2446
|
Tue Dec 22 15:49:31 2009 |
kiwamu | Update | General | e-log restarted |
I found the e-log has been down around 3:40pm, then I restarted the e-log. Now it's working.
Thanks. |
2448
|
Wed Dec 23 16:34:25 2009 |
Koji | Update | IOO | MCT QPD/MC REFL QPD disabled |
For a certain investigation of the sum/diff module for MCT QPD/MC REFL QPD, I removed it from the system.
|
2449
|
Wed Dec 23 17:33:14 2009 |
rana | Update | ASS | OAF Feedaround ON and doing something good |
The Rai box ran out of batteries a couple of days ago and so the data is no good. I've put the Ranger back on the SR560 for now (but with the damping resistor removed, so the gain is 2x more than before). |
2450
|
Thu Dec 24 01:25:29 2009 |
kiwamu | Update | Electronics | impedance analyzing |
The validation for high impedance measurement has been well done. 
The impedance measurement is one of the keys for designing the EOM circuit.
So far I was very struggling to measure the high impedance ( above several 1000 Ohm) at RF because the EOM circuit has a high impedance at its resonance.
Finally I realized that the measured impedance was suppressed by a parasitic resistance, which especially reduces the impedance at the resonance.
Also I found that we can extract the TRUE impedance data by subtracting the effect of the parasitic resistance from resultant data.
In order to confirm whether this subtraction works correctly or not, the impedance was directly re-measured with another analyzer for crosscheck.
The followers are details about the re-measurement.
(measurement )
The measurement has been performed with help from Peter and Frank. ( Thank you !)
By using network analyzer AG4395A with the impedance test kit AG43961A (these are at the PSL lab.), the impedance of resonant circuit with EOM was measured.
The picture of setup is attached. This impedance test kit allows to measure typically 0.1 [Ohm]-1M [Ohm] and frequency range of 100kHz-500MHz.
(result)
The resultant plot is attached. In the plot the blue curve represents the impedance measured by usual analyzer at 40m.
Note this curve is already subtracted the effect of the parasitic resistance.
( the parasitic resistance is in parallel to the circuit and it has ~7.8k Ohm, which is measured while the probe of the analyzer stays open. )
The red curve is the re-measured data using the impedance test kit.
The important point is that; these two peak values at the resonance around 40MHz show good agreement in 10%.
The resonant frequencies for two data differs a little bit, which might be the effect of a stray capacitance ( ~several [pF] )
The red curve has a structure around 80MHz, I think this comes from the non-coaxial cables, which connect the circuit and analyzing kit.
You can see these cables colored black and red in the picture.
( conclusion )
Our measurement with the subtraction of the parasitic resistance effect is working reliably ! |
Attachment 1: DSCN0421.JPG
|
|
Attachment 2: EOM.png
|
|
2451
|
Thu Dec 24 19:13:29 2009 |
Koji | Update | IOO | MCT QPD investigation |
I found that MCT QPD has a dependence of the total output on the position of the spot. Since the QPD needs the supply and bias voltages from the sum/diff amp, I could not separate the problems of the QPD itself and the sum/diff amplifier by the investigation on Tuesday. On Wednesday, I investigated a generic quad photodiode interface module D990692.
...I was so disappointed. This circuit was left uninvestigated and used so long time with the following sorrowful conditions.
- This circuit has 4 unbuffered inputs with input impedance of 300~400 Ohm. It's way too low!
- Moreover, those channels have different input impedances. Ahhhh.
- Even worse, the QPD circuit D990272 has output impedance of 50 Ohm.
- The PCB of this circuit has four layers. It is quite difficult to make modifications of the signal route.
- It is a headache: this circuit is "generic" and used in many places.
D990692 has 4 channel inputs that are not buffered. Each channel has two high impedance buffers but they are used only for the monitors. The signal paths have no buffer.
The differential amplifier is formed by R=1k Ohm. The inverted side of the input has 1kOhm impedance. The non-inverted side has 1.5kOhm impedance.
CH1: 10K // 1.5k // 1.5k // 1k = 411 Ohm
CH2: 10K // 1.5k // 1k // 1k = 361 Ohm
CH3: 10K // 1k // 1k // 1k = 323 Ohm
CH4: 10K // 1k // 1.5k // 1k = 361 Ohm
Considering the output impedance of 50Ohm for the QPD, those too low input impedances result in the following effect:
- Because of the voltage division, we suffer absolute errors of 10.8~13.4%. This is huge.
- Because of the input impedance differences, we suffer a relative error of 1.5%~3%. This is also huge.
Unfortunately, the circuit has no room to modify; the signal paths are embedded in the internal layer.
I decided to replace the resistors of the sum/diff amps from 1k to 10k. Also the input impedance of the buffer was removed as the input is terminated by the sum/diff amps in any case.This changes the input inpedance to the followings:
CH1: 15k // 15k // 10k = 4286 Ohm
CH2: 15k // 10k // 10k = 3750 Ohm
CH3: 10k // 10k // 10k = 3333 Ohm
CH4: 10K // 15k // 10k = 3750 Ohm
These yield the absolute error of 1.2-1.5%. The relative error is now 0.3%. I can accept these numbers, but later I should put additional terminating resistors to compensate the differencies.
So far I have modified the resistors for the MCT as the modification for a QPD needs 17 10k resistors.
Next thing I have to check is the dependence of the QPD outputs on the spot positions.
-----------------------------------------------
Edit: Feb 11, 2010
I talked with Frank and he pointed out that the impedances are not the matter but the gains of the each channels are the matters (after considering the output impedance of the QPD channels).
If we assume the ideal voltage sources at the QPD and the symmetric output impedances of 50Ohm, the gain of the each circuit are affected but the change should be symmetric.
He found that several things:
- The analog switch (MAX333) used in the QPD unit adds more output impedance (somewhat randomly!).
- The resistance of the sum/diff circuits may vary each other unless we use 0.1% resistors.
|
Attachment 1: D990692.png
|
|
2453
|
Sun Dec 27 20:05:28 2009 |
kiwamu | Update | Computers | can not communicate with front-ends |
In this evening I found that fb40m has been down, then I restarted fm40m successfully.
However there still is a problem, the reflective memory can not communicate with some front-end CPUs ( such as c1iscey, c1susvme, ...etc.)
Right now I don't have any ideas about this, I am leaving them as they are now .... we can deal with them tomorrow.
The followers are what I did.
(1) ssh to fb40m then "pkill tpman"
(2) telnet to fb40m then typed "shutdown". ( These procedure are on the 40m wiki)
(3) make sure fb40m gets recovered while watching the medm screen C0DAQ_DETAIL.adl
(4) run the backup script in fb40m
(5) in order to fix the communication problem, physically turn off c1dcuepics and c0daqctrl
(6) keying some front-end CPUs. ---> still some of front ends indicate RED on the medm screen C0DAQ_DETAIL.adl ( figure attached )
|
Attachment 1: C0DAQ_DETAIL.png
|
|
2454
|
Sun Dec 27 23:44:59 2009 |
rana | Update | Electronics | MCT QPD investigation |
Quote: |
I found that MCT QPD has dependence of the total output on the position of the spot. Since the QPD needs the supply and bias voltages from the sum/diff amp, I could not separate the problems of the QPD iteself and the sum/diff amplifier by the investigation on Tuesday. On Wednesday, I investigated a generic quad photodiode interface module D990692.
|
This is indeed sad. But, we can perhaps bypass all of this by just using the individual segment outputs. According to the circuit diagram and the c1iool0 .db file, we should be able to just do the math on the segments and ignore the VERT/HOR/SUM signals completely. In that case, we can just use high impedance for the sum/diff buffers as Koji says and not suffer from the calibration errors at all I think. |
2455
|
Mon Dec 28 01:17:01 2009 |
Koji | Update | Electronics | MCT QPD investigation |
Unfortunately, the signals for individual segments also suffer from the voltage drop as all of the low impedance amplifiers are hung from the same input.
In order to utilize the individual channels, we anyway have to remove the resistors for the VERT/HOR/SUM amps.
That is possible. But does it disable some fast channels for future ASC purposes?
Quote: |
This is indeed sad. But, we can perhaps bypass all of this by just using the individual segment outputs. According to the circuit diagram and the c1iool0 .db file, we should be able to just do the math on the segments and ignore the VERT/HOR/SUM signals completely. In that case, we can just use high impedance for the sum/diff buffers as Koji says and not suffer from the calibration errors at all I think.
|
|
2456
|
Mon Dec 28 10:29:31 2009 |
Jenne | Update | Computers | Monday Morning Bootfest |
Nothing like a good ol' Bootfest to get back into the swing of things after vacation....
It was a regular bootfest, keying crates and running everyone's startup.cmd . There wasn't any RFM funny business which we had been dealing with a lot earlier in December (maybe Kiwamu took care of that part of things last night).
After finishing the bootfest, I tried to re-enable the watchdogs. I noticed that the optics weren't damping at all (not that any of them were swinging crazily, they just weren't damped like regular). This was traced to the OSEM sensor inputs and outputs being disabled on all of the suspensions' screens. I suspect that no burt-restoring happened after c1dcuepics was powercycled yesterday.
All of the optics are now happy as clams. |
2457
|
Mon Dec 28 12:35:57 2009 |
Jenne | Update | SUS | MC2 is having a bad day |
MC2 is having a bad day, and I'm not yet sure why. It's to do with the damping though. When the damping is off, after a little while it will settle to ~30mV or so on the Watchdog screen. When I enable all of the outputs and then turn on the damping, the optic gets kicked up. It's like there's a minus sign error somewhere, maybe in a bad burtrestore? This has been going on since I did my morning bootfest.
It's started to sit down and play nicely now. Is someone doing magic remotely that is fixing things that I hadn't figured out yet? |
2458
|
Mon Dec 28 12:45:55 2009 |
Koji | Update | SUS | MC2 is having a bad day |
The MCL path of MC2 was in a strange state as the filters were activated as if it is in lock even though we had no lock. So I manually ran "mcdown". This reset the filters of the MCL path.
Quote: |
MC2 is having a bad day, and I'm not yet sure why. It's to do with the damping though. When the damping is off, after a little while it will settle to ~30mV or so on the Watchdog screen. When I enable all of the outputs and then turn on the damping, the optic gets kicked up. It's like there's a minus sign error somewhere, maybe in a bad burtrestore? This has been going on since I did my morning bootfest.
It's started to sit down and play nicely now. Is someone doing magic remotely that is fixing things that I hadn't figured out yet?
|
|
2459
|
Mon Dec 28 15:19:19 2009 |
Alberto | Update | Computers | Burtrestored to Dec 26 at 20:00 |
Since it wasn't sure whether all the front-ends had been restored after the bootfest, I burtrestored everything to Dec 26 at 20:00.
Always keep in mind that to burtrestore c1dcuepics, the snapshot file has to be modified by hand by moving the last quote up to the line before the last. |
2460
|
Mon Dec 28 15:34:14 2009 |
Alberto | Update | ABSL | Working on the AP table |
I opened the auxiliary laser's shutter.
I'm currently working on the AP table. |
2461
|
Mon Dec 28 18:35:27 2009 |
Alberto | Update | ABSL | Working on the AP table |
Quote: |
I opened the auxiliary laser's shutter.
I'm currently working on the AP table.
|
I finished working on the table.
I closed the AUX NPRO's shutter. |
2462
|
Mon Dec 28 23:56:44 2009 |
kiwamu, rana | Update | Computers | add the HILO drift channels to the burt |
The HIGH and LOW channels are added into the burt request file "/target/c1losepics/autoBurt.req".
These values are used to colorize the alarm texts in the "C1DRIFT_MONITOR.adl" like a threshold. (the screenshot attached)
Hereafter these values will be automatically restored by the burt. Happy ! |
Attachment 1: Screenshot_DRIFTMON.png
|
|
2464
|
Tue Dec 29 04:28:27 2009 |
kiwamu, rana, haixing | Update | Cameras | New Video Switch Installed |
We have installed the new Video Matrix.
Its still in an intermediate state, so don't try to "fix" anything before Kiwamu and I get back onto it in the afternoon.
The status so far is that we have removed the old switch (it was a 256 input x 128 output !! mux) and installed the new one in the same rack. We have hooked it up to the CDS network and have set up its matrix by using the web interface (i.e. NOT EPICS).
Along the way, we discovered that there is lack of impedance matching in the video all over the 40m. Video signals are RF and need to be treated that way. The PSL signals are T'd around and sent on 50 Ohm cables to high impedance monitor inputs.
We should eliminate any switches besides the new one (called Luciana) and control the PSL's Video Monitor from the main MUX interface. No more Rogue Video Switches.
Another couple of things we have found is about RCR camera.
(1) The long cable which connects the RCR camera box and the video matrix doesn't work. Although the signal is alive and we can see it by the local tv monitor nearby PSL.
(1) The reflected beam going to the camera is too weak to see in the monitor. We found a strange polarized cube splitter in front of the camera. We should modify it sooner or later. |
2465
|
Tue Dec 29 13:57:20 2009 |
Rana, Kiwamu, and Haixing | Update | Photos | Photos of video switch box |
Before we installed the video switch box, we also took some photos of it. We uploaded them onto the 40m Picasa.
Video Matrix
The first photo is the an entire view of the switch box. The following four photos are the details of the switch matrix.
The slideshow below is a dump of the last several months of photos from the Olympus. The originals have been deleted.
|
2466
|
Wed Dec 30 09:57:53 2009 |
steve | Update | PSL | thirsty water chiller |
I added 600 cc of Arrowhead Distilled Water to the chiller.
60 days plot shows that about every ~ 10 days I have to add some.
Please check the water level yourself. |
Attachment 1: htemp60d.png
|
|
2467
|
Wed Dec 30 10:58:48 2009 |
Alberto | Update | General | All watchdogs tripped this morning |
This morning I found all the watchdogs had tripped during the night.
I restored them all.
I can't damp ITMX. I noticed that its driving matrix is all 1s and -1s as the the right values had been lost in some previous burtrestoring. |
2468
|
Wed Dec 30 18:01:03 2009 |
Alberto, Rana | Update | General | All watchdogs tripped this morning |
WQuote: |
This morning I found all the watchdogs had tripped during the night.
I restored them all.
I can't damp ITMX. I noticed that its driving matrix is all 1s and -1s as the the right values had been lost in some previous burtrestoring.
|
Rana fixed the problem. He found that the side damping was saturating. He lowered the gain a little for a while, waited for the the damping to slow down the optic and then he brought the gain back where it was.
He also upadted the MEDM screen snapshot. |
2470
|
Wed Dec 30 22:17:07 2009 |
kiwamu | Update | General | Camera input and monitor output |
The input channels of the cameras and the output channels for the monitors are summarized on the wiki.
The channel table on the wiki is very helpful when you want to make a change in the video matrix.
thank you. |
2474
|
Mon Jan 4 17:26:01 2010 |
Mott | Update | General | T & R plots for Y1 and Y1S mirrors |
The most up-to-date T and R plots for the Y1 and Y1S mirrors, as well as a T measurement for the ETM, can be found on:
http://lhocds.ligo-wa.caltech.edu:8000/40m/Upgrade_09/Optics/RTmeasurement
|
2475
|
Tue Jan 5 01:31:09 2010 |
Jenne | Update | WienerFiltering | New Wiener Filters installed in PEM IIR matrix on OAF screen |
Using the techniques employed at LLO, and then by Rana here at the 40m a few weeks ago, Wiener filters have been installed on the inputs of all of the PEM IIR channels which are hooked up to the 110B PEM ADCU. Some slight modifications have taken place to the code, and it's all been checked in to the 40m svn.
I have installed the filters into: All 6 Wilcoxon accelerometers, the Ranger seismometer, and one of the Guralps (GUR1). The other Guralp is currently connected through the ASS/OAF machine's ADC, so it's not used in this test. The filters are all labeled "Wiener", and are FM1 in the C1:ASS-TOP_PEMIIR_## filter banks.
The first figure below is the output of the Wiener Filter calculation program. It shows the uncorrected MC_L (black) and the corrected MC_L (red), using the optimal wiener filter. This is as good as we should be able to do with these sensors in these positions.
The second figure is a DTT shot of me trying out the nifty new filters. They seem to maybe do a teensy bit on the microseism, but otherwise it's a bit unremarkable. Hopefully I'll get better subtraction during the day, when the base level for MC_L is higher. Here, Black is uncorrected MC_L, Red is the corrected MC_L, Blue is the actuation channel, and green is an example seismometer channel to illustrate the ground motion at the time.
For posterity, since it's not all in one elog that I can find, the order of operations to install a Wiener Feed Forward filter is as follows:
1. (When you can borrow the IFO) Take a very careful TF of the plant, between your actuation point and your error signal readout. At the 40m, this means between C1:ASS-TOP_SUS_MC1_EXC and C1:IOO-MC_L, since we actuate by pushing on the MC1 coils. At the sites / future 40m, this would be between the HEPI (or STACIS) and the error signal. The limit of how good your Feed Forward can do will depend heavily on how good this TF is. Coherence should be above ~0.95 for all points. Export this data from DTT as a .txt file, using units "Complex (abs/rad)".
2. Run fitMC12MCL.m (or equivalent wrapper file) to fit the transfer function you just took with some Poles and Zeros. Make sure to edit the wrapper file with your new .txt file's name so you're getting a fresh TF (if you've just taken one).
3. (Again, when you can borrow the IFO) Run getMCdata.m (or equivalent) to fetch witness channel data and error signal data. At the 40m, this usually means C1:IOO-MC_L, and witness sensors which are around the MC chambers. This data should be taken at a time when the cavity is locked, but pretty much on it's own. (i.e. probably shouldn't have Common Mode feedback on the MC - so the MC should be locked, but not the full IFO, for example.)
4. Run c1winoiir.m (the main program here, which contains some of these notes). This will take in the TF data you've fit, and the witness channel data you have, and calculate the optimal combination of Wiener filters for your witness channels. It pre-filters your witness data by your TF, then calculates the Wiener filter. The resulting FIR filters are saved in a file.
5. Run firfit.m This will take the FIR Wiener filters you've just created, and convert them conveniently to IIR filters, in a format to be copied directly into Foton. For each witness channel, you'll get the IIR filter in 2 formats: the first is for copying into the Foton .txt file (ex ASS.txt), and the second is for copying into the Foton gui, in the "Command" box on the filter design screen. The "o" at the end of the copy-able filter indicates to Foton that it is a Z-Plane Online filter. Copy filters appropriately (there should be a line preceding each set of SOS filter formats to indicate which channel this Wiener filter is for...these channel names are extracted from your getMCdata.m)
6. Save your Foton file, and update your Coefficients in MEDM. Enable your outputs to actuators, and watch magic happen!
On the To-Do list:
Check the transfer of signal btwn PEMIIR matrix and the 9x1 'matrix' that sends the signals to the SUS inputs. In the SimuLink, the input to the 9x1 matrix is a bundle of 8 numbers (the 8 outputs of the PEMIIR matrix), but it looks like it only pays attention to the first one. Need to figure out how to make it realize that it's a bundle, not a single number.
Also, the OAF up / down scripts don't seem to be working on any of the control room computers. This needs to be checked in to / fixed (but not tonight....) |
Attachment 1: MCwino-FFtest_4Jan10_sameFiltersAsinEPICS.png
|
|
Attachment 2: OAF-FF_test_4Jan10.png
|
|
2480
|
Tue Jan 5 17:32:59 2010 |
Jenne | Update | WienerFiltering | New Wiener Filters installed in PEM IIR matrix on OAF screen |
EDIT 6 Jan 2010: Shouldn't have done this. My bad. The AA32 is on the other PEM matrix because the Adaptive code runs at 64Hz, so there's downsampling, calculating, and upsampling which goes on. The Feed Forward path all runs at 2kHz, the regular rate of the ASS/OAF machine. All of these filters are turned off (although I haven't deleted them from Foton). Since we're focusing on low frequency stuff and trying to get that to do some subtraction, we're not worrying about the junk at higher frequencies just yet.
I have put AA32 filters into the PEMIIR matrix's input filter banks (ie, C1:ASS-TOP_PEMIIR_##), to match the ones that are in the same places in the regular PEM matrix on the OAF screen.
I redid the uncorrected vs. corrected MC_L DTT printout, shown below. You can see that there's less junk at higher frequencies in the Blue (actuation channel) trace, which is good. |
Attachment 1: OAF-FF_test_5Jan10.png
|
|
2483
|
Thu Jan 7 14:08:46 2010 |
Jenne | Update | Computers | We haven't had a bootfest yet this week.....so today's the day |
All the DAQ screens are bright red. Thumbs down to that. |
2484
|
Thu Jan 7 14:55:36 2010 |
Jenne | Update | Computers | We haven't had a bootfest yet this week.....so today's the day |
Quote: |
All the DAQ screens are bright red. Thumbs down to that.
|
All better now. |
2486
|
Fri Jan 8 10:38:35 2010 |
josephb, koji | Update | Computers | RFM and Megatron |
Last night, we installed the VMI 5565 RFM card into Megatron. After turning off the watchdogs for the ETMY optic, we disconnected the RFM fiber, and connected it to megatron, then powered it up.
We modified the RCG code to have 3 rfmio blocks, which were reading 0x11a1c0 (ascPit), 0x11a1c4 (ascYaw), and 0x11a1c8 (lscPos). These were connected to the approriate filter module inputs, and we also added grounds to the front of the rfmio blocks (we looked at the ass code which was setup that way, so we just did the same thing). When we started it however, it didn't read properly. If we turned off the input and set and offset, it calculated the output of the filter module correctly, (i.e. just the offset value), but as soon as we turned on the input, it was set to 0, no matter the offset value, which indicated it was reading something correctly.
After this test, the RFM fibers were reconnected to c1iscey, we rebooted c1iscey, and we confirmed that the system was working properly again. We turned the watch dogs back on for ETMY.
|
2487
|
Fri Jan 8 11:43:22 2010 |
josephb, alex | Update | Computers | RFM and Megatron |
Alex came over with a short RFM cable this morning. We used it to connect the rfm card in c1iscey to the rfm card megatron
Alex renamed startup.cmd in /cvs/cds/caltech/target/c1iscey/ to startup.cmd.sav, so it doesn't come up automatically. At the end we moved it back.
Alex used the vxworks command d to look at memory locations on c1iscey. Such as d 0xf0000000, which is the start of the rfm code location. So to look at 0x11a1c8 (lscPos) in the rfm memory, he typed "d 0xf011a1c8". After doing some poking around, we look at the raw tst front end code (in /home/controls/cds/advLigo/src/fe/tst), and realized it was trying to read doubles. The old rts code uses floats, so the code was reading incorrectly.
As a quick fix, we changed the code to floats for that part. They looked like:
etmy_lsc = filterModuleD(dsp_ptr,dspCoeff,ETMY_LSC,cdsPciModules.pci_rfm[0]? *(\
(double *)(((void *)cdsPciModules.pci_rfm[0]) + 0x11a1c8)) : 0.0,0);
And we simply changed the double to float in each case. In addition we changed the RCG scripts locally as well (if we do a update at some point, it'll get overwritten). The file we updated was /home/controls/cds/advLigo/src/epics/util/lib/RfmIO.pm
Line 57 and Line 84 were changed, with double replaced with float.
return "cdsPciModules.pci_rfm[0]? *((float *)(((void *)cdsPciModules.pci
_rfm[$card_num]) + $rfmAddressString)) : 0.0";
. " *((float *)(((char *)cdsPciModules.pci_rfm[$card_nu
m]) + $rfmAddressString)) = $::fromExp[0];\n"
This fixed our ability to read the RFM card, which now can read the LSC POS channel, for example.
Unfortunately, when we were putting everything the way it was with RFM fibers and so forth, the c1iscey started to get garbage (all the RFM memory locations were reading ffff). We eventually removed the VME board, removed the RFM card, looked at it, put the RFM card back in a different slot on the board, and returned c1iscey to the rack. After this it started working properly. Its possible in all the plugging and unplugging that the card somehow had become loose.
The next step is to add all the channels that need to be read into the .mdl file, as well as testing and adding the channel which need to be written.
|
2488
|
Fri Jan 8 15:40:14 2010 |
josephb, alex | Update | Computers | RFM and RCG |
Alex added a new module to the RCG, for generating RFMIO using floats. This has been commited to CVS. |
2491
|
Sat Jan 9 09:47:03 2010 |
Alberto | Update | LSC | Problems trying to lock the arms |
This morning I've been having problems in trying to lock the X arm.
The X arm's filter FM6 in the LSC screen starts blinking as it was halfloaded. Then the transmitted power drops from 1 to ~0.5 and eventually the arm loses lock.
To me it looked like a computer related issue. So I decide to reboot C1ISCEX by powercycling it.
That doesn't seem to have solved the problem. The X arm can get locked but TRX slowly moves between 0.2 and 1. |
2492
|
Sat Jan 9 11:07:30 2010 |
Alberto | Update | LSC | Problems trying to lock the arms |
Quote: |
This morning I've been having problems in trying to lock the X arm.
The X arm's filter FM6 in the LSC screen starts blinking as it was halfloaded. Then the transmitted power drops from 1 to ~0.5 and eventually the arm loses lock.
To me it looked like a computer related issue. So I decide to reboot C1ISCEX by powercycling it.
That doesn't seem to have solved the problem. The X arm can get locked but TRX slowly moves between 0.2 and 1.
|
The X arm is now locked with TRX stable at ~1.
I think earlier on today I was having problems with running the alignment scripts from op540. Now I'm controlling the IFO from Rosalba and I can easily and stably lock all degrees of freedom.
I needed the X arm to be locked to align the auxiliary beam of the AbsL experiment to the IFO. To further stabilize TRX I increased the loop gain from 1 to 1.5.
Now the auxiliary beam is well aligned to the IFO and the beat is going through the PRC. I'm finally ready to scan the recycling cavity.
I also changed the gain of the PRC loop from -0.1 to -0.5. |
2493
|
Sat Jan 9 15:02:01 2010 |
Alberto | Update | ABSL | PRC scanning |
I scanned the PRC in the frequency range of 30-60 MHz, untill the PLL lost lock. But everything is working fine.
The PRC remained lock for all time, with SPOB at ~1000.
I'm leaving the lab now, planning to come back tomorrow.
I turned the flipping mirrors down and closed the mechanical shutter of the auxiliary NPRO. |
2494
|
Sun Jan 10 13:32:09 2010 |
Haixing | Update | SUS | transfer function measurement of the quadrant maglev circuit |
I have assembled the circuit and the control box for the quadrant magnetic levitation yesterday. The final setup is shown
in the figure below:
 
Due to my carelessness, I I connected the wrong ends of the power supply. I damaged 4 op-amp and one voltage
regulator during this assembly. This stupid mistake spent me several hours to fix, and I got a bitter lesson;-(
Afterwards, I replaced those op-amps and reconnected the power supply . Kiwamu helped me and we measured
the transfer function of this circuit. The transfer function agrees with the specification in the schematics which
has a integrator below 1 Hz and a differentiator from 5 to 20 Hz. The bode plot for the measured transfer function
is the following:


Today I tested the photodetector parts and found that there is a mysterious oscillation. Whenever I connect the
photodector input A of the circuit (as indicated in the figure below),

the output of the op-amp has a 500k Hz oscillation shown up in the oscilloscope.This happens even A is disconnected from
the photodetector and connected to an open end wire. I don't know how to eliminate it, and its amplitude is so large (peak to
peak is around 2.5 V) which completely dominates the photodetector output. Does anybody has some ideas? Thanks.

|
2495
|
Sun Jan 10 15:47:26 2010 |
Koji | Update | SUS | transfer function measurement of the quadrant maglev circuit |
1. Why do all of the BNCs have no GND connection? Each should have the individual cables to the ground. Each signal line and the corresponding ground line should be twisted together.
2. This looks the (usual) oscillation of the V-I conversion stage but I can't tell anything as I don't have the circuit diagram of the whole circuit.
3. In a certain case, putting some capacitance at the feedback may help. Read P.11 of the data sheet of LT1125. Try to put some capacitors from 20pF to some larger one whether it changes the situation or not. I suppose the bandwidth of your sensor can be ~1kHz. So putting a capacitance less than 10nF still has no effect to the servo. |
2497
|
Sun Jan 10 16:50:34 2010 |
Haixing | Update | SUS | transfer function measurement of the quadrant maglev circuit |
Quote: |
1. Why do all of the BNCs have no GND connection? Each should have the individual cables to the ground. Each signal line and the corresponding ground line should be twisted together.
2. This looks the (usual) oscillation of the V-I conversion stage but I can't tell anything as I don't have the circuit diagram of the whole circuit.
3. In a certain case, putting some capacitance at the feedback may help. Read P.11 of the data sheet of LT1125. Try to put some capacitors from 20pF to some larger one whether it changes the situation or not. I suppose the bandwidth of your sensor can be ~1kHz. So putting a capacitance less than 10nF still has no effect to the servo.
|
1. They are all connected to the box which has a single connection to the board ground. If I connect each of them to the ground, there would be many small loops
of ground. Of course, I should have replaced all the connectors such that the they are disconnected to the box as point out by Robert.
2. The oscillation disappears after I add 5 nF capacitor in parallel to the existing resistor. Thank you very much for pointing this out. |
2498
|
Sun Jan 10 17:15:25 2010 |
Koji | Update | SUS | transfer function measurement of the quadrant maglev circuit |
1. Yes. That is the bad. You should eventually replace the BNCs to the isolated ones.
2. OK. I like to emphasize again that everyone works on electronics should read data sheets more carefully and seriously because they have many important practical instructions to exploit full performance of the components.
Quote: |
Quote: |
1. Why do all of the BNCs have no GND connection? Each should have the individual cables to the ground. Each signal line and the corresponding ground line should be twisted together.
2. This looks the (usual) oscillation of the V-I conversion stage but I can't tell anything as I don't have the circuit diagram of the whole circuit.
3. In a certain case, putting some capacitance at the feedback may help. Read P.11 of the data sheet of LT1125. Try to put some capacitors from 20pF to some larger one whether it changes the situation or not. I suppose the bandwidth of your sensor can be ~1kHz. So putting a capacitance less than 10nF still has no effect to the servo.
|
1. They are all connected to the box which has a single connection to the board ground. If I connect each of them to the ground, there would be many small loops
of ground. Of course, I should have replaced all the connectors such that the they are disconnected to the box as point out by Robert.
2. The oscillation disappears after I add 5 nF capacitor in parallel to the existing resistor. Thank you very much for pointing this out.
|
|
2500
|
Mon Jan 11 09:18:44 2010 |
Alberto | Update | General | Measurement running |
I'm working on the AbsL experiment. A measurement which involved the PRC locked is running at the moment.
Please make sure of not interfering with the interferometer until it is done. Thank you. |
2502
|
Mon Jan 11 11:06:53 2010 |
Alberto | Update | ABSL | Measurement running |
Quote: |
I'm working on the AbsL experiment. A measurement which involved the PRC locked is running at the moment.
Please make sure of not interfering with the interferometer until it is done. Thank you.
|
I'm done for the moement.
I realized that I need to take into account somehow the DC power from the photodiode. By now the measurement of the transmitted beat's power is affected by the total power circulating inside of the PRC and thus it depends on the cavity alignment.
I closed the laser shutter and turned down the flipping mirrors.
I'm planning to restart measuring by 2.30pm today. Till then the interferometer is available. |
2503
|
Mon Jan 11 14:16:59 2010 |
Jenne | Update | PEM | Gur2 cables reconnected to the PEM ADCU |
So that we can use both Guralps for Adaptive stuff, and so that I can look at the differential ground motion spectra, I've reconnected the Guralp Seismometers to the PEM ADCU, instead of where they've been sitting for a while connected to the ASS ADC. I redid the ASS.mdl file, so that the PEM and PEMIIR matricies know where to look for the Gur2 data. I followed the 'make ass' procedure in the wiki. The spectra of the Gur1 and Gur2 seismometers look pretty much the same, so everything should be all good.
There's a problem with DataViewer though: After selecting signals to plot, whenever I hit the "Start" button for the realtime plots, DataViewer closes abruptly.
When I open dataviewer in terminal, I get the following output:
allegra:~>dataviewer
Warning: communication protocol revision mismatch: expected 11.3, received 11.4
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: communication protocol revision mismatch: expected 11.3, received 11.4
msgget: No space left on device
allegra:~>framer4 msgget:msqid: No space left on device
Does anyone have any inspiration for why this is, or what the story is? I have GR class, but I'll try to follow up later this afternoon. |
2504
|
Mon Jan 11 16:59:14 2010 |
Alberto | Update | ABSL | Interferometer Busy |
I'm currently running a measurement on the PRC.
Please don't interfere with the IFO until it is done. Talk with Alberto if you've been intending to work inside the lab.
Thank you. |
2505
|
Mon Jan 11 19:36:13 2010 |
Alberto | Update | ABSL | Measurement running |
Leaving for dinner. Back in ~1hr.
I left a measurement running. Please don't interfere with it till I'm back. Thanks. |
2506
|
Mon Jan 11 21:49:17 2010 |
Jenne | Update | ABSL | Measurement running |
Quote: |
Leaving for dinner. Back in ~1hr.
I left a measurement running. Please don't interfere with it till I'm back. Thanks.
|
Per Alberto's instructions, I have closed the shutter on his laser so that the Adaptive Team can play with the Mode Cleaner. |