ID |
Date |
Author |
Type |
Category |
Subject |
2330
|
Wed Nov 25 11:10:05 2009 |
Jenne | Update | Computers | 40m frame builder backup acting funny |
Quote: |
Quote: |
As part of the fb40m restart procedure (Sanjit and I were restarting it to add some new channels so they can be read by the OAF model), I checked up on how the backup has been going. Unfortunately the answer is: not well.
I'll check in with the frame builder again tomorrow, to make sure that it's all good.
|
All is well again in the world of backups. We are now up to date as of ~midnight last night.
|
Backup Fail. At least this time however, it threw the appropriate error code, and sent me an email saying that it was unhappy. Alan said he was going to check in with Stuart regarding the confusion with the ssh-agent. (The other day, when I did a ps -ef | grep agent, there were ~5 ssh-agents running, which could have been then cause of the unsuccessful backups without telling me that they failed. The main symptom is that when I first restart all of the ssh-agent stuff, according to the directions in the Restart fb40m Procedures, I can do a test ssh over to ldas-cit, to see what frames are there. If I log out of the frame builder and log back in, then I can no longer ssh to ldas-cit without a password. This shouldn't happen....the ssh-agent is supposed to authenticate the connection so no passwords are necessary.)
I'm going to restart the backup script again, and we'll see how it goes over the long weekend. |
2329
|
Wed Nov 25 11:02:54 2009 |
Alberto | Update | ABSL | AbsL PLL not able to lock |
Quote: |
Last night something happened on the beat between the PSL beam and the auxiliary NPRO beam, that spoiled the quality of the beating I had before. As a result the PLL has become unable to lock the two lasers.
The amplitude of the beat at the spectrum analyzer has gone down to -40 dBm from -10 that it was earlier. The frequency has also become more unstable so that now it can be seen writhing within tens of KHz.
Meanwhile the power of the single beams at the PLL photodiode hasn't changed, suggesting that the alignment of the two beam didn't change much.
Changes in the efficiency of the beating between the two beams are not unusual. Although that typically affects only the amplitude of the beat and wouldn't explain why also its frequency has become unstable. Tuning the alignment of the PLL optics usually brings the amplitude back, but it was uneffective today.
It looks like something changed in either one of the two beams. In particular the frequency of one of the two lasers has become less stable.
Another strange thing that I've been observing is that the amplitude of the beat goes down (several dBm) as the beat frequency is pushed below 50 MHz. Under 10 MHz it even gets to about -60 dBm.
I noticed the change yesterday evening at about 6pm, while I was taking measurements of the PLL open loop tranfer function and everything was fine. I don't know whether it is just a coincidence or it is somehow related to this, but Jenne and Sanjit had then just rebooted the frame builder.
|
I confirm what I said earlier. The amplitude of the beat is -10 dBm at 300MHz. It goes down at lower frequencies. In particular it gets to-60 dBm below 20 MHz. For some strange reason that I couldn't explain the beating efficiency has become poorer at low frequencies. |
2328
|
Wed Nov 25 10:20:47 2009 |
Alberto | Update | ABSL | AbsL PLL not able to lock |
Last night something happened on the beat between the PSL beam and the auxiliary NPRO beam, that spoiled the quality of the beating I had before. As a result the PLL has become unable to lock the two lasers.
The amplitude of the beat at the spectrum analyzer has gone down to -40 dBm from -10 that it was earlier. The frequency has also become more unstable so that now it can be seen writhing within tens of KHz.
Meanwhile the power of the single beams at the PLL photodiode hasn't changed, suggesting that the alignment of the two beam didn't change much.
Changes in the efficiency of the beating between the two beams are not unusual. Although that typically affects only the amplitude of the beat and wouldn't explain why also its frequency has become unstable. Tuning the alignment of the PLL optics usually brings the amplitude back, but it was uneffective today.
It looks like something changed in either one of the two beams. In particular the frequency of one of the two lasers has become less stable.
Another strange thing that I've been observing is that the amplitude of the beat goes down (several dBm) as the beat frequency is pushed below 50 MHz. Under 10 MHz it even gets to about -60 dBm.
I noticed the change yesterday evening at about 6pm, while I was taking measurements of the PLL open loop tranfer function and everything was fine. I don't know whether it is just a coincidence or it is somehow related to this, but Jenne and Sanjit had then just rebooted the frame builder. |
2326
|
Wed Nov 25 08:43:08 2009 |
Alberto | Update | ABSL | Working on the AP table |
I'm working on the AP table. I also opened the auxiliary NPRO shutter. The auxiliary beam is on its path on the AP table and PSL table. |
2325
|
Wed Nov 25 03:05:15 2009 |
rob | Update | Locking | Measured MC length |
Quote: |
What I meant was the VCO driver, not the FSS box.
As for the frequency, all written numbers were the Marconi displays.
The number on the frequency counter was also recorded, and so will be added to the previous entry shortly...
Quote: |
I propose that from now on, we indicate in the elog what frequencies we're referring to. In this case, I guess its the front panel readback and not the frequency counter -- what is the frequency counter readback? And is everything still locked to the 10 MHz from the GPS locked Rubidium clock?
Plus, what FSS Box? The TTFSS servo box? Or the VCO driver? As far as I know, the RC trans PD doesn't go through the FSS boxes, and so its a real change. I guess that a bad contact in the FSS could have made a huge locking offset.
|
|
Locking has gone sour. The CARM to MCL handoff, which is fairly early in the full procedure and usally robust, is failing reliably.
As soon as the SUS-MC2_MCL gain is reduced, lock is broken. There appears to be an instability around 10Hz. Not sure if it's related. |
2324
|
Tue Nov 24 19:16:02 2009 |
Alberto | Update | ABSL | working on the AP table |
Quote: |
I'm working on the AP table. I also opened the auxiliary NPRO shutter. The auxiliary beam is on its path on the AP table and PSL table.
|
Closing the AP table and the NPRO shutter now. |
2323
|
Tue Nov 24 18:24:54 2009 |
Sanjit | Configuration | Adaptive Filtering | ASS channels added to framebuilder |
[Sanjit, Jenne, Rob, Joe]
We added and tested the following channels from "/cvs/cds/gds/param/tpchn_C3.par" to "/cvs/cds/caltech/chans/daq/C1ASS.ini" appending a "_2048" extension to the channel name (as the name of a channel in .ini and .par files must be different):
[C1:ASS-TOP_CORR_IN1_2048]
[C1:ASS-TOP_ERR_EMPH_IN1_2048]
[C1:ASS-TOP_PEM_10_IN1_2048]
[C1:ASS-TOP_PEM_11_IN1_2048]
[C1:ASS-TOP_PEM_12_IN1_2048]
[C1:ASS-TOP_PEM_15_IN1_2048]
[C1:ASS-TOP_PEM_16_IN1_2048]
[C1:ASS-TOP_PEM_17_IN1_2048]
[C1:ASS-TOP_PEM_18_IN1_2048]
[C1:ASS-TOP_PEM_19_IN1_2048]
[C1:ASS-TOP_PEM_20_IN1_2048]
[C1:ASS-TOP_PEM_24_IN1_2048]
[C1:ASS-TOP_PEM_2_IN1_2048]
[C1:ASS-TOP_PEM_3_IN1_2048]
[C1:ASS-TOP_PEM_4_IN1_2048]
These five-line entries for each channels in the .par file were manually copy pasted from the .ini file, should think about a smarter way...
The old .par file is kept as: /cvs/cds/caltech/chans/daq/C1ASS.ini.20Nov2009
The current one is also saved as: /cvs/cds/caltech/chans/daq/C1ASS.ini.24Nov2009
And, the current one is committed to the svn.
NOTE: In the first attempt, the channel names were mistakenly kept the same in both the .ini and .par files and this caused DAQ daemon to crash badly. It could only be recovered by hard reboot of the frame builder. Important info here: Jenne's elog 2316 |
2322
|
Tue Nov 24 16:06:45 2009 |
Jenne | Update | Computers | 40m frame builder backup acting funny |
Quote: |
As part of the fb40m restart procedure (Sanjit and I were restarting it to add some new channels so they can be read by the OAF model), I checked up on how the backup has been going. Unfortunately the answer is: not well.
I'll check in with the frame builder again tomorrow, to make sure that it's all good.
|
All is well again in the world of backups. We are now up to date as of ~midnight last night. |
2321
|
Tue Nov 24 14:33:22 2009 |
Alberto | Update | ABSL | working on the AP table |
I'm working on the AP table. I also opened the auxiliary NPRO shutter. The auxiliary beam is on its path on the AP table and PSL table. |
2320
|
Tue Nov 24 10:36:21 2009 |
Koji | Update | LSC | Measured MC length |
What I meant was the VCO driver, not the FSS box.
As for the frequency, all written numbers were the Marconi displays.
The number on the frequency counter was also recorded, and so will be added to the previous entry shortly...
Quote: |
I propose that from now on, we indicate in the elog what frequencies we're referring to. In this case, I guess its the front panel readback and not the frequency counter -- what is the frequency counter readback? And is everything still locked to the 10 MHz from the GPS locked Rubidium clock?
Plus, what FSS Box? The TTFSS servo box? Or the VCO driver? As far as I know, the RC trans PD doesn't go through the FSS boxes, and so its a real change. I guess that a bad contact in the FSS could have made a huge locking offset.
|
|
2319
|
Tue Nov 24 08:00:16 2009 |
rana | Update | LSC | Measured MC length |
I propose that from now on, we indicate in the elog what frequencies we're referring to. In this case, I guess its the front panel readback and not the frequency counter -- what is the frequency counter readback? And is everything still locked to the 10 MHz from the GPS locked Rubidium clock?
Plus, what FSS Box? The TTFSS servo box? Or the VCO driver? As far as I know, the RC trans PD doesn't go through the FSS boxes, and so its a real change. I guess that a bad contact in the FSS could have made a huge locking offset.
|
2318
|
Mon Nov 23 21:36:38 2009 |
Koji | Update | IOO | Aligned PMC/RC |
I aligned the beam goes to PMC. It increased the MC Trans from 8.25 to 8.30.
I also aligned the beam goes to RC.
When I touched the FSS box (wrong: this was the VCO driver) that was close to one of the steering mirror, suddenly the RC trans increased.
It is now 9.8. I am afraid that it gets saturated. I could not reproduce the phenomenon. This could be caused by a bad contact?
Note that I didn't see there is any loose optic. |
Attachment 1: 091123_PSL.png
|
|
2317
|
Mon Nov 23 21:30:29 2009 |
Jenne | Update | LSC | Measured MC length |
With Koji's help, I measured the length of the Mode Cleaner.
The new modulation frequencies (as quoted on the Marconi front panels) are:
165.980580 MHz
33.196116 MHz
132.784464 MHz
199.176696 MHz
The Frequency Counter readback is 165980584.101 Hz (a 4Hz difference). All of the Marconi's front-panel frequencies read ###.##### MHz Ext, and the Frequency standard has it's "locked" light illuminated, and the 1pps input light blinking, so I think everything is still nicely locked to the frequency standard, and the frequency standard is locked to the GPS.
While changing the marconi's, I accidentally touched the MC's 29.5 MHz marconi. It is set back to the nominal value (according to Kiwamu's rack photos) of 29.485MHz. But the phase might be sketchy, although hopefully this doesn't matter since we don't do a double demodulation with it.
I also ran the scripts in the wiki page: How To/Diagonalize DRMI Length Control to set the DD Phases.
|
2316
|
Mon Nov 23 19:36:28 2009 |
Jenne | Update | Adaptive Filtering | How to add ASS channels, so that they're saved to frames |
[Jenne, Sanjit]
We would like several channels from the OAF/ASS screen to be saved to frames, so that we can use the channels for our OAF model. In theory, this should involve uncommenting the desired channels in the .ini file (.../caltech/chans/daq/C1ASS.ini), and restart the frame builder. Since this .ini file was generated a long time ago, and things have been changed since then, the chnnums in the .ini file and the corresponding .par file don't match up. We need to go through the .par file (/cvs/cds/gds/param/tpchn_c3.par), and look up the chnnums for our channels, and copy those numbers into the .ini file. Figuring out what was going on involved many fb40m restarts, but on the last one of the night, I restarted the backup script, so it should (hopefully) run tonight, and get all of the frames that we've been missing.
Notes to self:
* When adding channels to other front ends, the end of the process is to click the blue button on the C0DAQ_DETAIL screen next to your computer. C1ASS isn't on that screen. Instead, in the C1ASS_GDS screen, click DAQ Reload.
* The channel names for the Test Points and the .ini files must be different. That's why there's a '_2048' suffix at the end of every channel in our .ini file.
* tpchn_C1 is all of the old-style system test points. tpchn_C2 is the C1OMC, and tpchn_C3 is for the C1ASS testpoints.
* When uncommenting channels in the C1ASS.ini file, make sure acquire is set to 1 for every channel we want saved. The default in this .ini file is set to acquire = 0. |
2315
|
Mon Nov 23 17:53:08 2009 |
Jenne | Update | Computers | 40m frame builder backup acting funny |
As part of the fb40m restart procedure (Sanjit and I were restarting it to add some new channels so they can be read by the OAF model), I checked up on how the backup has been going. Unfortunately the answer is: not well.
Alan imparted to me all the wisdom of frame builder backups on September 28th of this year. Except for the first 2 days of something having gone wrong (which was fixed at that time), the backup script hasn't thrown any errors, and thus hasn't sent any whiny emails to me. This is seen by opening up /caltech/scripts/backup/rsync.backup.cumlog , and noticing that after October 1, 2009, all of the 'errorcodes' have been zero, i.e. no error (as opposed to 'errorcode 2' when the backup fails).
However, when you ssh to the backup server to see what .gwf files exist, the last one is at gps time 941803200, which is Nov 9 2009, 11:59:45 UTC. So, I'm not sure why no errors have been thrown, but also no backups have happened. Looking at the rsync.backup.log file, it says 'Host Key Verification Failed'. This seems like something which isn't changing the errcode, but should be, so that it can send me an email when things aren't up to snuff. On Nov 10th (the first day the backup didn't do any backing-up), there was a lot of Megatron action, and some adding of StochMon channels. If the fb was restarted for either of these things, and the backup script wasn't started, then it should have had an error, and sent me an email. Since any time the frame builder's backup script hasn't been started properly it should send an email, I'm going to go ahead and blame whoever wrote the scripts, rather than the Joe/Pete/Alberto team.
Since our new raid disk is ~28 days of local storage, we won't have lost anything on the backup server as long as the backup works tonight (or sometime in the next few days), because the backup is an rsync, so it copies anything which it hasn't already copied. Since the fb got restarted just now, hopefully whatever funny business (maybe with the .agent files???) will be gone, and the backup will work properly.
I'll check in with the frame builder again tomorrow, to make sure that it's all good. |
2314
|
Mon Nov 23 16:28:12 2009 |
steve | Summary | Cameras | Video swicher options |
Quote: |
Steve is summarizing the Video Matrix choices into this Wiki page:
http://lhocds.ligo-wa.caltech.edu:8000/40m/Electronics/VideoMUX
Requirements:
Price: < 5k$
Control: RS-232 and Ethernet
Interface: BNC (Composite Video)
Please check into the page on Monday for a final list of choices and add comments to the wiki page.
|
Composite video matrix switchers with 32 BNC in and 32 BNC channels out are listed. |
2313
|
Mon Nov 23 11:03:00 2009 |
steve | Update | SUS | jackhammer special well under control |
Quote: |
I've changed the watchdog rampdown script so it brings the SUS watchdogs to 220, instead of the 150 it previously targeted. This is to make tripping less likely with the jackhammering going on next door. I've also turned off all the oplev damping.
|
Saturday's special event of braking up the large concrete pieces in CES bay was un event full. |
Attachment 1: dig10d.png
|
|
Attachment 2: P1050740.JPG
|
|
2312
|
Mon Nov 23 10:11:03 2009 |
steve | Update | PEM | long term temp fluctuation of the 40m lab |
Quote: |
This first plot shows the RC temperature channels' performance from 40 days ago, before we disabled the MINCO PID controller. Although RCTEMP is supposed to be the out of loop sensor, what we really care about is the cavity length and so I've plotted the SLOW. To get the SLOW on the same scale, I've multiplied the channel by 10 and then adjusted the offset to get it on the same scale.
The second plot shows a period after that where there is no temperature control of the can at all. Same gain scaling has been applied to SLOW as above, so that instead of the usual 1 GHz/V this plot shows it in 0.1 GHz/V.
The third plot shows it after the new PID was setup.
Summary: Even though the PID loop has more gain, the true limit to the daily fluctuations in the cavity temperature and the laser frequency are due to the in-loop sensors measuring the wrong thing. i.e. the out-of-loop temperature is too different from the in-loop sensor. This can possibly be cured with better foam and better placement of the temperature sensors. Its possible that we're now just limited by the temperature gradients on the can.
|
Here is a 7 years plot of of the 40m temperature variations. |
Attachment 1: 7ytemp.jpg
|
|
2311
|
Mon Nov 23 00:46:09 2009 |
rana, rob | Update | PSL | ISS RIN: Its too high by 10x |
This plot shows the RIN as measured by the ISS. Its ~2 x 10^-7, whereas its supposed to be more like 3 x 10^-8.
The ISS has DC coupled RIN channels (with a _F suffix) and AC coupled RIN channels (with a _FW suffix). By using a swept sine, Rob determined that the AC coupled channels have an AC coupling pole at ~80 Hz. The attached plot uses this and then has the overall gain adjusted to match with the _F channels below 10 Hz.
The _F channels can be converted directly into RIN by just dividing the spectra by the mean value of the time series. The dark offset of these channels is small and so this only introduces a ~5-10% calibration error.
Question #1: Why is the RIN so bad? According to the MEDM screen, the photocurrent on the MON/SENS PDs is 1.9/1.3 mA. That's sort of low, but should still allow us to get 5x10^-8 in RIN.
Question #2: Does it make an effect on the current DC Readout work? IF so, should we try to fix up the ISS in a temporary way? Since the in-loop and out-of-loop detectors are completely coherent, all of the noise is likely just unsuppressed noise from the laser. We are unable to increase the gain because of the high frequency noise from the NPRO.
Let's remember to replace this ISS with a new one that can drive an AOM. Need a volunteer to get us a new ISS.
|
Attachment 1: Untitled.png
|
|
2310
|
Fri Nov 20 17:44:38 2009 |
Jenne | Update | Adaptive Filtering | Some svn shenanigans |
[Sanjit, Jenne]
Sanjit and I are trying to put names to some signals which exist in SimuLink land, but which don't (yet) exist in EPICS land. The deelio is that for each of the chosen SEIS signals in the ASS_TOP_PEM screen, the signal is split. One part of the signal is used to decide how the adaptive filter should look, and the other part is actually used when doing the on-line subtraction. Previously only the part of the signal which is used to decide on the Adaptive Filter could be seen on the screens, and had names.
Before touching anything on the Simulink ASS.mdl, I did an svn check in, which put things at revision 36639.
To try to make the desired signals exist, I put cdsFilt boxes (to create filter modules for each of these signals), and gave each of them a name (kind of like the Neverending Story....once they have a name, they'll exist). My new names are C1:ASS-TOP_PEM_#_APPLY, which correspond to the previously-existing C1:ASS-TOP_PEM_#_ADPT (these are the ones that are along the top of the ASS_TOP_PEM matrix screen). This version of the simulink model was checked in, and the svn is now at revision 36640.
We then did some "make clean", "make ass" and "make install-ass" action, and burt restored c1assepics, but nothing seems to be happening. The screen doesn't have white boxes all over the place, and we didn't get any errors when we did the makes, and I'm sure we burt restored correctly (made sure the ASS GDS screen had a 1 in the lower left box etc), but all the values on the screen are still zero.
When we ran the ass front end in terminal on the c1ass machine, we did see an error: "Invalid chan num found 2 = 30624" "DAQ init failed -- exiting". I think this means that we need to have told some file somewhere that I was going to be adding 8 new channels. (maybe an .ini file?) Hopefully the Joe & Peter team can help us out with this, since they've been doing this kind of thing for the new system.
Moral of the story is, the new (non-working) simulink file has been svn checked in as revision 36640, and we're reverting to revision 36639, which was before I touched anything today. |
2309
|
Fri Nov 20 16:18:56 2009 |
rob | Configuration | SUS | watchdog rampdown |
I've changed the watchdog rampdown script so it brings the SUS watchdogs to 220, instead of the 150 it previously targeted. This is to make tripping less likely with the jackhammering going on next door. I've also turned off all the oplev damping. |
2308
|
Fri Nov 20 13:54:45 2009 |
Alberto | Omnistructure | Environment | New Paper and Cardboard Recycling Bins Introduced to the 40m |
The 40m produces a large amount of paper and cardboard waste. It would be worth it if we disposed those kind of garbages for recycling.
I set up two new garbage bins in the lab: one in the control rooms that adds up to the can/bottle recycling bin, and one other one in the office area, next to the printer for general paper disposal.
People in the lab are strongly invited to make use of the two new garbage bins and recycle their paper and cardboard waste.
Boxes can be larger than the garbage bin, so I'd recommend people to crash them before throwing them into the bin.


|
2307
|
Fri Nov 20 11:32:48 2009 |
Haixing | Update | SUS | Magnetic levitation |
I added an integrator to increase the gain at low frequencies (below 5 Hz). In addition, I increased
the band of the differentiator. The schematics for both integrator and differentiator are the following:

The magnetic is stably levitated.

I turned off the light to get rid of 60Hz noise on the photodiode. I tried to measured the
open-loop transfer function of this setup, but somehow the SR560 is always saturate
when I injected the signal from SR785, which produces some weird results at
low-frequencies.
In addition, I found out that when the light is turned on, the levitation
can be stable even when I inverted the sign of the control loop. The control signal
on the osciloscope is the following:

This oscillator is around 120 Hz, which should be the harmonics of 60 Hz from light pollution.
I am not sure exactly why it is stable when the control-loop sign is flipped. This could
be similar to the Pauli trap in the iron trap, because the coil not only provides a force
but also provides the rigidity. The sign of such rigidity depends on the sign of the control
current. If such oscillating rigidity changes at a frequency much higher than the response
frequency of the magnet, it will stablize the system simply by significantly increasing
the inertial of the magnet.More investigations are essential to completely understand it.
For information about Pauli trap, one can look at the wikipedia:
http://en.wikipedia.org/wiki/Quadrupole_ion_trap
|
2306
|
Fri Nov 20 11:14:22 2009 |
josephb, alex | Configuration | Computers | test points working on megatron and we may have filters with switch outputs built in |
Alex tooked at the channel definitions (can be seen in tpchn_C1.par), and noticed the rmid was 0.
However, we had set in testpoint.par the tst system to C-node1 instead of C-node0. The final number inf that and the rmid need to be equal. We have changed this, and the test points appear to be working now.
However, the confusing part is in the tst model, the gds_node_id is set to 1. Apparently, the model starts counting at 1, while the code starts counting at 0, so when you edit the testpoint.par file by hand, you have to subtract one from whatever you set in the model.
In other news, Alex pointed me at a CDS_PARTS.mdl, filters, "IIR FM with controls". Its a light green module with 2 inputs and 2 outputs. While the 2nd set of input and outputs look like they connect to ground, they should be iterpreted by the RCG to do the right thing (although Alex wasn't positive it works, it worth trying it and seeing if the 2nd output corresponds to a usable filter on/off switch to connect to the binary I/O to control analog DW. However, I'm not sure it has the sophistication to wait for a zero crossing or anything like that - at the moment, it just looks like a simple on/off switch based on what filters are on/off. |
2305
|
Fri Nov 20 11:01:58 2009 |
josephb, alex | Configuration | Computers | Where to find RFM offsets |
Alex checked out the old rts (which he is no longer sure how to compile) from CVS to megatron, to the directory:
/home/controls/cds/rts/
In /home/controls/cds/rts/src/include you can find the various h files used. Similarly, /fe has the c files.
In the h files, you can work out the memory offset by noting the primary offset in iscNetDsc40m.h
A line like suscomms.pCoilDriver.extData[0] determines an offset to look for.
0x108000 (from suscomms )
Then pCoilDriver.extData[#] determines a further offset.
sizeof(extData[0]) = 8240 (for the 40m - you need to watch the ifdefs, we were looking at the wrong structure for awhile, which was much smaller).
DSC_CD_PPY is the structure you need to look in to find the final offset to add to get any particular channel you want to look at.
The number for ETMX is 8, ETMY 9 (this is in extData), so the extData offset from 0x108000 for ETMY should be 9 * 82400. These numbers (i.e. 8 =ETMX, 9=ETMY) can be found in losLinux.c in /home/controls/cds/rts/src/fe/40m/. There's a bunch of #ifdef and #endif which define ETMX, ETMY, RMBS, ITM, etc. You're looking for the offset in those.
So for ETMY LSC channel (which is a double) you add 0x108000 (a hex number) + (9 * 82400 + 24) (not in hex, need to convert) to get the final value of 0x11a160 (in hex).
-----------
A useful program to interact with the RFM network can be found on fb40m. If you log in and go to:
/usr/install/rfm2g_solaris/vmipci/sw-rfm2g-abc-005/util/diag
you can then run rfm2g_util, give it a 3, then type help.
You can use this to read data. Just type help read. We had played around with some offsets and various channels until we were sure we had the offsets right. For example, we fixed an offset into the ETMY LSC input, and saw the corresponding memory location change to that value. This utility may also be useful for when we do the RFM test to check the integrity of the ring, as there are some diagnostic options available inside it. |
2304
|
Fri Nov 20 00:18:45 2009 |
rana | Summary | Cameras | Video MUX Selection Wiki page |
Steve is summarizing the Video Matrix choices into this Wiki page:
http://lhocds.ligo-wa.caltech.edu:8000/40m/Electronics/VideoMUX
Requirements:
Price: < 5k$
Control: RS-232 and Ethernet
Interface: BNC (Composite Video)
Please check into the page on Monday for a final list of choices and add comments to the wiki page. |
2303
|
Thu Nov 19 18:49:55 2009 |
Alberto | Configuration | elog | Elog debugging output - Down time programmed today to make changes |
Quote: |
We want the elog process to run in verbose mode so that we can see what's going. The idea is to track the events that trigger the elog crashes.
Following an entry on the Elog Help Forum, I added this line to the elog starting script start-elog-nodus:
./elogd -p 8080 -c /cvs/cds/caltech/elog/elog-2.7.5/elogd.cfg -D -v > elogd.log 2>&1
which replaces the old one without the part with the -v argument.
The -v argument should make the verbose output to be written into a file called elogd.log in the same directory as the elog's on Nodus.
I haven't restarted the elog yet because someone might be using it. I'm planning to do it later on today.
So be aware that:
We'll be restarting the elog today at 6.00pm PT. During this time the elog might not be accessible for a few minutes.
|
I tried applying the changes but they didn't work. It seems that nodus doesn't like the command syntax.
I have to go through the problem...
The elog is up again. |
2302
|
Thu Nov 19 16:04:48 2009 |
Alberto | Configuration | elog | Elog debugging output - Down time programmed today to make changes |
We want the elog process to run in verbose mode so that we can see what's going. The idea is to track the events that trigger the elog crashes.
Following an entry on the Elog Help Forum, I added this line to the elog starting script start-elog-nodus:
./elogd -p 8080 -c /cvs/cds/caltech/elog/elog-2.7.5/elogd.cfg -D -v > elogd.log 2>&1
which replaces the old one without the part with the -v argument.
The -v argument should make the verbose output to be written into a file called elogd.log in the same directory as the elog's on Nodus.
I haven't restarted the elog yet because someone might be using it. I'm planning to do it later on today.
So be aware that:
We'll be restarting the elog today at 6.00pm PT. During this time the elog might not be accessible for a few minutes. |
2301
|
Thu Nov 19 11:33:15 2009 |
josephb | Configuration | Computers | Megatron |
I tried rebooting megatron, to see if that might help, but everything still acts the same.
I tried using daqconfig and changed channels from deactiveated to activated. I learned by activating them all, that the daq can't handle that, and eventually aborts from an assert checking a buffer size being too small. I also tried activating 2 and looking at those channels, and it looks like the _DAQ versions of those channels work, or at least I get 0's out of C1:TST-ETMY_ASCPIT_OUT_DAQ (which is set in C1TST.ini file).
I've added the SENSOR channels back to the /csv/cds/caltech/chans/daq/C1TST.ini file, and those are again working in data viewer.
At this point, I'm leaving megatron roughly in the same state as last night, and am going to wait on a response from Alex. |
2300
|
Thu Nov 19 10:19:04 2009 |
josephb | Update | Computers | Megatron tst status |
I did a full make clean and make uninstall-daq-tst, then rebuilt it. I copied a good version of filters to C1TST.txt in /cvs/cds/caltech/chans/ as well as a good copy of screens to /cvs/cds/caltech/medm/c1/tst/.
Test points still appear to be broken. Although for a single measurement in dtt, I was somehow able to start, although the output in the results page didn't seem to have any actual data in the plots, so I'm not sure what happened there - after that it just said unable to select test points. It now says that when starting up as well. The tst channels are the only ones showing up. However, the 1k channels seem to have disappeared from Data Viewer, and now only 16k channels are selectable, but they don't actually work. I'm not actually sure where the 1k channels were coming from earlier now that I think about it. They were listed like C1:TST-ETMY-SENSOR_UL and so forth.
RA: Koji and I added the SENSOR channels by hand to the .ini file last night so that we could have data stored in the frames ala c1susvme1, etc. |
2299
|
Thu Nov 19 09:55:41 2009 |
josephb | Update | Computers | Trying to get testpoints on megatron |
This is a continuation from last night, where Peter, Koji, and I were trying to get test point channels working on megatron and with the TST module.
Things we noticed last night:
We could run starttst, and ./daqd -c daqdrc, which allowed us to get some channels in dataviewer. The default 1k channel selection works, but none of the testpoints do.
However, awgtpman -s tst does appear in the processes running list.
The error we get from dataviewer is:
Server error 861: unable to create thread
Server error 23328: unknown error
datasrv: DataWriteRealtime failed: daq_send: Illegal seek
Going to DTT, it starts with no errors in this configuration. Initially it listed both MDC and TST channels. However, as a test, I moved the tpchn_C4.par , tpchn_M4.par and tpchn_M5.par files to the directory backup, in /cvs/cds/caltech/target/gds/param. This caused only the TST channels to show up (which is what we want when not running the mdc module.
We had changed the daqdrc file in /cvs/cds/caltech/target/fb, several times to get to this state. According to the directions in the RCG manual written by Rolf, we're supposed to "set cit_40m=1" in the daqdrc file, but it was commented out. However, when we uncommented it, it started causing errors on dtt startup, so we put it back. We also tried adding lines:
set dcu_rate 13 = 16384;
set dcu_rate 14 = 16384;
But this didn't seem to help. The reason we did this is we noticed dcuid = 13 and dcuid = 14 in the /cvs/cds/caltech/target/gds/param/tpchn_C1.par file. We also edited the testpoint.par file so that it correctly corresponded to the tst module, and not the mdc and mdp modules. We basically set:
[C-node1]
hostname=192.168.1.2
system=tst
in that file, and commented everything else out.
At this point, given all the things we've changed, I'm going to try a rebuild of the tst and daq and see if that solves things.
|
2298
|
Thu Nov 19 09:48:54 2009 |
steve | Update | PEM | construction effect |
8 days plot: Thurdsay, Friday, Sat and Sun without construction |
Attachment 1: varseism.png
|
|
2297
|
Thu Nov 19 09:25:19 2009 |
steve | Update | MOPA | water was added to the laser chiller |
I added ~500 cc of distilled water to the laser chiller yesterday. |
Attachment 1: htempwtr.png
|
|
2296
|
Thu Nov 19 08:53:12 2009 |
pete | Frogs | Environment | diesel fumes |
Instead of doing RCG stuff, I went to Millikan to work on data analysis as I couldn't stand the fumes from the construction. (this morning, 8am) |
2295
|
Wed Nov 18 22:38:17 2009 |
Koji | Update | Electronics | multi-resonant EOM --- EOM characterization --- |
How can I get those values from the figure?
Quote: |
But indeed it has lead inductance of 12nH, resistance of 0.74[Ohm], and parasitic capacitance of 5.5pF.
|
|
2294
|
Wed Nov 18 16:58:36 2009 |
kiwamu | Update | Electronics | multi-resonant EOM --- EOM characterization --- |
In designing the whole circuit it is better to know the characteristic of the EOM.
I made impedance measurement with the EOM (New Focus model 4064) and I found it has capacitance of 10pF.
This is good agreement with the data sheet which says "5-10pF".
The measured plot is attached below. For comparison there also plotted "open" and "10pF mica".
In the interested band( from 1MHz to 100MHz), EOM looks just a capacitor.
But indeed it has lead inductance of 12nH, resistance of 0.74[Ohm], and parasitic capacitance of 5.5pF.
In some case we have to take account of those parasites in designing.

|
2293
|
Wed Nov 18 16:24:25 2009 |
pete | Configuration | SUS | ETMY suspension conencted to megatron ADC/DAC |
/cvs/cds/caltech/target/fb/daqd -c daqdrc
This starts the FB.
Now the dataviewer and DTT work!
Quote: |
0) Now the connection for the ETMY suspension was restored in a usual state. It damps well.
1) I thought it would be nice to have dataviewer and DTT working.
So far, I could not figure out how to run daqd and tpman .
- I tried to configure
/cvs/cds/caltech/target/fb/daqdrc
/cvs/cds/caltech/target/fb/master
/cvs/cds/caltech/chans/daq/C1TST.ini (via daqconfig )
- I also looked at
/cvs/cds/caltech/targetgds/param/tpchn_C1.par
but I don't understand how it works. The entries have dcuids of 13 and 14 although C1TST has dcuid of 10.
The file is unmodified.
I will try it later when I got a help of the experts.
2) Anyway, I went ahead. I tried to excite suspension by putting some offset.
It seems to have no DAC output. I checked the timing signal. It seems that looks wrong clock.
I looked at DAC output by putting 5000,10000,15000,20000,25000cnt to UL/UR/LR/LL/SD coils.
I could not find any voltage out of the DAC in any channels.
Then, I checked the timing signal. This clock seems to have wrong frequency.
What we are using now is a clock with +/-4V@4MHz. (Differential)
Maybe 4194304Hz (=2^22Hz)?
I went to 1Y3 and checked the timing signal for 16K. This was +/-4V@16kHz. (Diffrential)
The possible solution would be
- bring a function generator at the end and try to input a single end 4V clock.
- stretch a cable from 1Y3 to 1Y9. (2pin lemo)
Quote: |
I have connected ETMY sus electronics to megatron ADC/DAC.
We continue this state until 15:00 of today.
|
|
|
2292
|
Wed Nov 18 14:55:59 2009 |
kiwamu | Update | Electronics | multi-resonant EOM --- circuit design ---- |
The circuit design of multi-resonant EOM have proceeded.
By using numerical method, I found the some best choice of the parameters (capacitors and inductors).
In fact there are 6 parameters (Lp, L1, L2, Cp, C1, C2) in the circuit to be determined.

In general the less parameter gives the less calculation time with performing the numerical analysis. Of course it looks 6 parameters are little bit large number.
In order to reduce the arbitrary parameters, I put 4 boundary conditions.
Each boundary conditions fixed resonant peaks and valleys; first peak=11MHz, third peak=55MHz, first valley=19MHz, second valley=44MHz.

So now the remaining arbitrary parameters successfully get reduced to 2. Only we have to do is optimize the second peak as it to be 29.5MHz.
Then I take C1 and C2 as free parameters seeing how the second peak agree with 29.5MHz by changing the value of the C1 and C2.

the red color represents the good agreement with 29.5MHz, in contrast blue contour represents the bad.
You can see some best choice along the yellow belt. Now what we should do is to examine some of that and to select one of those. |
2291
|
Wed Nov 18 12:33:30 2009 |
Koji, josephb | Configuration | SUS | ETMY suspension conencted to megatron ADC/DAC |
Hurraaaah!
We've got the damping of the suspension.
The Oplev loops has also worked!
The DAC channnel swapping was the last key!
DataViewer snapshot to show the damping against an artificial excitation was attached
Quote:
|
Quote: |
Koji, Rana
The megatron DAC was temporaly connected to the suspension electronics for the DAC test. We went down to ETMY as we could not excite the mirror.
The DAC is putting correct voltages to the channels. However, the anti imaging filter test output does not show any signal.
This means something wrong is there in the DAC I/F box or the cables to the AI circuit. We will check those things tomorrow.
The ETMY was restored to the usual configuration.
|
It appears the front panel for the DAC board is mis-labeled. Channels 1-8 are in fact 9-16, and 9-16 are the ones labeled 1-8. We have put on new labels to reduce confusion in the future.
|
|
Attachment 1: Untitled.png
|
|
2290
|
Wed Nov 18 11:27:33 2009 |
Koji, josephb | Configuration | SUS | ETMY suspension conencted to megatron ADC/DAC |
Quote: |
Koji, Rana
The megatron DAC was temporaly connected to the suspension electronics for the DAC test. We went down to ETMY as we could not excite the mirror.
The DAC is putting correct voltages to the channels. However, the anti imaging filter test output does not show any signal.
This means something wrong is there in the DAC I/F box or the cables to the AI circuit. We will check those things tomorrow.
The ETMY was restored to the usual configuration.
|
It appears the front panel for the DAC board is mis-labeled. Channels 1-8 are in fact 9-16, and 9-16 are the ones labeled 1-8. We have put on new labels to reduce confusion in the future. |
2289
|
Wed Nov 18 01:12:15 2009 |
rana | Update | PEM | seismometers were not saturating during Halloween weekend |
|
Attachment 1: Untitled.png
|
|
2288
|
Wed Nov 18 00:38:33 2009 |
rana | Summary | Electronics | Voltage Noise of the SR560's OUTPUTs (the back panel) |
I've measured the voltage noise of the SR560's lead acid battery outputs; they're not so bad.
Steve ordered us some replacement lead-acid batteries for our battery powered pre-amps (SR560). In the unit he replaced, I measured the noise using the following setup:
SR560 Busby Box
(+12V/GND) -------------AC Input Out ---------------- SR785
The SR785 was DC coupled and auto-ranged. The input noise of the SR785 was measured via 50 Ohm term to be at least 10x less than the SR560's noise at all frequencies.

Its clear that this measurement was spoiled by the low frequency noise of the Busby box below 10 Hz. Needs a better pre-amp. |
2287
|
Tue Nov 17 21:21:30 2009 |
rob | Update | SUS | ETMY UL OSEM |
Had been disconnected for about two weeks. I found a partially seated 4-pin LEMO cable coming from the OSEM PD interface board. |
2286
|
Tue Nov 17 21:10:35 2009 |
rana | Summary | Electronics | Busby Low Noise Box: Photos and Upgrades |

It looked like the Busby Low Noise Box had too much low frequency noise and so I upgraded it. Here is a photo of the inside - I have changed out the 0.8 uF AC coupling cap with a big, white, 20 uF one I found on Rob's desk.
The Busby Box is still working well. The 9V batteries have only run down to 7.8V. The original designer also put a spare AD743 (ultra low current FET amp) and a OP27 (best for ~kOhm source impedances) in there.
Here's the noise after the fix. There's no change in the DC noise, but the AC noise is much lower than before:

I think that the AC coupled noise is higher because we are seeing the current noise of the opamp. In the DC coupled case, the impedance to ground from the input pins of the opamp is very low and so the current noise is irrelevant.
The change I implemented, puts in a corner frequency of fc = 1/2/pi/R/C = 1/2/pi/10e3/20e-6 = 0.8 Hz.
Overall, the box is pretty good. Not great in terms of current noise and so it misses getting an A+. But its easily a solid A-. |
2285
|
Tue Nov 17 21:10:30 2009 |
Koji | Configuration | SUS | ETMY suspension conencted to megatron ADC/DAC |
Koji, Rana
The megatron DAC was temporaly connected to the suspension electronics for the DAC test. We went down to ETMY as we could not excite the mirror.
The DAC is putting correct voltages to the channels. However, the anti imaging filter test output does not show any signal.
This means something wrong is there in the DAC I/F box or the cables to the AI circuit. We will check those things tomorrow.
The ETMY was restored to the usual configuration. |
2284
|
Tue Nov 17 21:09:17 2009 |
Jenne, rana | Update | General | Little Thorlabs Photodiode |
[Rana, Jenne]
We opened up the little Thorlabs battery operated PD to see what was inside. Rana took some pictures, and I drew a schematic (attached). It's just a diode, biased with a battery (albeit a crazy 22.5V battery).
---------------
Comment by KA: PD is Hamamatsu S1223-01 Si PIN diode.
What a crazy battery. The main point is that it looks like this can be used for reasonable purposes: uses a load resistor on the BNC connector and you can use some pre-amp (e.g. Busby box or SR560) to have a low noise PD readout. You can also use the SR560 in its A-B mode as an 'opamp'. Ground the A input and the use a pole at 1 Hz and make the Output go into the B input through some large series resistor. The BNC from the PD gets Teed into the B input as well.
Then this becomes a transimpedance circuit readout of the diode, using the current noise of the SR560 as the limit. |
Attachment 1: ThorlabsPD.png
|
|
2283
|
Tue Nov 17 15:54:34 2009 |
rana | Summary | PEM | 40 days of weather |
the inside temperature is alarming at the red level today - should check if the HIHI value is set correctly |
Attachment 1: Untitled.pdf
|
|
2282
|
Tue Nov 17 15:23:06 2009 |
Koji | Configuration | SUS | ETMY suspension conencted to megatron ADC/DAC |
OK. Now, Timing/ADC/DAC are working. It's almost there.
1) As a temporaly clock, I put a function generator at the back side of the ETMY.
Set it to the rectangular +/-4V@16384Hz. Connect it to D060064 PCIX Timing Interface Board in the IO Chasis.
That is a line receiver to feed the TTL signal into ADCs/DACs.
I confirmed the actual sampling clock is supplied to the ADC/DAC boards by looking at the SMB output of the D060064.
2) Restarted the realtime code.
3) I looked at DAC output by putting 5000,10000,15000,20000,25000cnt to UL/UR/LR/LL/SD coils again.
Yes! I could see the DAC channels are putting DC voltages.
4) Then I connected DAC CH0 to ADC CH0 using SCSI breaking up boards.
Yes! I could see the coil output switching change the ADC counts!
Now, we are ready to see the suspension damped. Check it out.
|
2281
|
Tue Nov 17 13:39:37 2009 |
Koji | Configuration | SUS | ETMY suspension conencted to megatron ADC/DAC |
0) Now the connection for the ETMY suspension was restored in a usual state. It damps well.
1) I thought it would be nice to have dataviewer and DTT working.
So far, I could not figure out how to run daqd and tpman .
- I tried to configure
/cvs/cds/caltech/target/fb/daqdrc
/cvs/cds/caltech/target/fb/master
/cvs/cds/caltech/chans/daq/C1TST.ini (via daqconfig )
- I also looked at
/cvs/cds/caltech/targetgds/param/tpchn_C1.par
but I don't understand how it works. The entries have dcuids of 13 and 14 although C1TST has dcuid of 10.
The file is unmodified.
I will try it later when I got a help of the experts.
2) Anyway, I went ahead. I tried to excite suspension by putting some offset.
It seems to have no DAC output. I checked the timing signal. It seems that looks wrong clock.
I looked at DAC output by putting 5000,10000,15000,20000,25000cnt to UL/UR/LR/LL/SD coils.
I could not find any voltage out of the DAC in any channels.
Then, I checked the timing signal. This clock seems to have wrong frequency.
What we are using now is a clock with +/-4V@4MHz. (Differential)
Maybe 4194304Hz (=2^22Hz)?
I went to 1Y3 and checked the timing signal for 16K. This was +/-4V@16kHz. (Diffrential)
The possible solution would be
- bring a function generator at the end and try to input a single end 4V clock.
- stretch a cable from 1Y3 to 1Y9. (2pin lemo)
Quote: |
I have connected ETMY sus electronics to megatron ADC/DAC.
We continue this state until 15:00 of today.
|
|
2280
|
Tue Nov 17 11:09:43 2009 |
Koji | Configuration | SUS | ETMY suspension conencted to megatron ADC/DAC |
I have connected ETMY sus electronics to megatron ADC/DAC.
We continue this state until 15:00 of today. (Restored 13:00) |