ID |
Date |
Author |
Type |
Category |
Subject |
230
|
Wed Jan 9 20:36:42 2008 |
Go | Update | Treasure | Money in lab |
Go's Desk. |
Attachment 1: DSC_0370.JPG
|
|
229
|
Wed Jan 9 20:29:47 2008 |
Dmass | AoG | TMI | Coffee Carafe |
If you have been using the coffee machine in the 40m, you may have noticed small brown flecks in your coffee mug. The carafe in the 40m has accumulated a layer of what is presumed to be old dried up coffee. When a small amount of water is swirled around in the bottom, flecks of the brown layer come off. Pictures below are of the inside of the carafe.
But does it provide adequate protection from 1064 light? |
Attachment 1: DSC_0363.JPG
|
|
Attachment 2: DSC_0365.JPG
|
|
Attachment 3: DSC_0368.JPG
|
|
228
|
Wed Jan 9 10:47:15 2008 |
fricke | Update | Computers | ethernet wiring in office/control room |
The electrical people have been here for three days, installing ethernet cables and drops in the 40m office area, in the old conduits where there was power and 10base2. Soon we will have reliable ethernet connections, instead of relying on switches hanging from the ceiling, etc! |
227
|
Tue Jan 8 15:20:17 2008 |
Pkp | Update | Cameras | GigE update |
[Tobin , Pinkesh]
Finally we got the camera doing something (other than giving out its attributes). The only thing that seems to work so far is a program called AAviewer, which converts the image into an ASCII format and displays it on the screen. If you want to play around with it, log into mafalda (131.215.113.23) via rana.ligo.caltech.edu. Access /cvs/cds/caltech/target/Prosilica/bin-pc/x86/ and there should be a few programs in there, one of which is AAviewer, which requires you to get an IP address (which is 131.215.113.103) for the camera right now. (You can also get the IP information via the ListCameras program). The camera is physically in the 40m near the network rack.
Other programs dont seem to be working and its probably due to the network/packetsize issues. Since linux2 can change its packetsize to a higher number, I will get it to compile on linux2 for now and then give it a shot. |
226
|
Mon Jan 7 09:01:39 2008 |
steve | Update | SUS | BS sus damping restored |
The BS sus damping was lost at 8am Sunday morning. |
Attachment 1: bssdl.jpg
|
|
225
|
Fri Jan 4 08:42:03 2008 |
steve | Update | SUS | etmy trips again |
ETMY sus damping tripped at 6am this morning
It was reset. We should put an accelerometer to the south end to see
the garbage dumping effect. |
Attachment 1: etmy20m.jpg
|
|
Attachment 2: etmy120s.jpg
|
|
Attachment 3: etmysenV.jpg
|
|
224
|
Thu Jan 3 12:38:49 2008 |
rob | Bureaucracy | TMI | Sore throat |
Quote: |
I did not feel anything wrong yesterday, but unfortunately I have a very much sore throat today. I need to drink warm milk with honey and rinse my throat often today. So far I do not have other illness symptomes (no fever), so I hope that this small disease will not last for a long time, but I feel that it is better for me to cure my sore throat today at home (and probably it is safer for others in 40-m).
I took yesterday the book "Digital Signal Processing", so I have it for reading at home.
Hope to see you tomorrow. |
I've added a new category--TMI--for entries along these lines. |
222
|
Thu Jan 3 09:55:11 2008 |
steve | Update | SUS | etmy sus damping restored |
ETMY watch dog was lost at midnight |
Attachment 1: etmy12h.jpg
|
|
221
|
Thu Jan 3 09:12:59 2008 |
steve | Update | PSL | MZ servo |
Here is MZ trend for one year and 40 days.
Now days it runs out of range on the low side.
This is the weakest link in the psl today. |
Attachment 1: mz1y.jpg
|
|
Attachment 2: mz40d.jpg
|
|
220
|
Thu Jan 3 08:53:55 2008 |
steve | Update | SUS | etmy vs etmx |
Rana have corrected sus gain damping setting of ETMY 8 days ago
gain settings: pos, pit, yaw & sd
etmx: 4,2,2,& -16
etmy: 4,2,2,& 50 |
Attachment 1: sus.jpg
|
|
219
|
Wed Jan 2 11:38:56 2008 |
tobin | Summary | WIKI-40M Update | wiki spam |
Our wiki keeps getting spammed. It turns out that you can upload attachments without a password, which is a bug. I'll ask David Barker whether there's a fix for this. |
218
|
Sun Dec 30 02:36:35 2007 |
pkp | Update | General | Another update |
So I followed suggestions 1 and 3 so far and have started writing up what all needs to be done in order to compile and use the camera. I wrote a program to ping the camera and get its properties and am working on a program to get an image. The reason why I want to write my own programs to do this, is that it will be easier to reuse and also to compile/use in the first place. The programs currently rest in /cvs/cds/caltech/target/Prosilica/ . Unfortunately I will be away for the next couple of days and will have another update on the 2nd. |
217
|
Thu Dec 27 18:18:56 2007 |
rana | Update | Computers | Update on GigE Camera |
Quote: | So I finally got the linux software to compile on mafalda. I got the software to dump all the information regarding the camera onto a file. I tried to take a tiff snap and came up empty. So I looked at the configuration file and realized that the camera thinks that the frame-rate is a nan. Am reading up the manual to fix the frame-rate manually and then will attempt to take another snap.
All the files are in a folder called Prosilica in /home/controls/ on mafalda. All the executables are in /home/controls/Prosilica/bin-pc/x86/* . On another note, I am looking for a name for the camera. Any suggestions are welcome. |
Suggestion #1: put this in the target area in a directory called /prosilica/. /home/controls is not backed up.
Suggestion #2: put a readme file in there on any work that was necessary to get it to compile.
Suggestion #3: make a wiki page for the camera with all the info that camera code developers will need |
216
|
Thu Dec 27 13:08:04 2007 |
rana | Update | SUS | ETMY tripping |
Here's a trend from the last 2 days of ETMX and ETMY. You can see that the damping gain increase
has made them now act much more alike. Problem fixed. |
Attachment 1: Untitled.png
|
|
215
|
Thu Dec 27 12:12:02 2007 |
pkp | Update | | Update on GigE Camera |
So I finally got the linux software to compile on mafalda. I got the software to dump all the information regarding the camera onto a file. I tried to take a tiff snap and came up empty. So I looked at the configuration file and realized that the camera thinks that the frame-rate is a nan. Am reading up the manual to fix the frame-rate manually and then will attempt to take another snap.
All the files are in a folder called Prosilica in /home/controls/ on mafalda. All the executables are in /home/controls/Prosilica/bin-pc/x86/* . On another note, I am looking for a name for the camera. Any suggestions are welcome. |
214
|
Wed Dec 26 15:12:48 2007 |
rana | Update | SUS | ETMY tripping |
It turned out that the ETMY POS damping gain was set to 1.0 while the ETMX had 3.8.
I put both ETMs to a POS gain of 4 and then also set the PIT, YAW and SIDE gains for
ETMY. Let's see if its more stable now.
In the next week or so Andrey should have perfected his damping gain setting technique
and the numbers should be set more scientifically. |
213
|
Wed Dec 26 15:00:06 2007 |
rana | Update | SUS | ETMY tripping |
Steve mentioned to me that ETMY is still tripping more than ETMX. The attached DV plot
shows the trend of the watchdog sensors; essentially the RMS fluctuations of the shadow
sensors. (note** DV can make PNG format plots directly which are much better than JPG
when making plots and much smaller than PS or PDF when plotting lots of points). |
Attachment 1: etm.png
|
|
212
|
Sat Dec 22 15:32:11 2007 |
tobin | AoG | Environment | ants |
Ants are everywhere: on the PSL table, on the circuit board I'm soldering...
I believe I have discovered their energy source. |
Attachment 1: DSC_0361.JPG
|
|
211
|
Sat Dec 22 00:52:57 2007 |
tobin | Configuration | PSL | ISS surgery |
In an attempt to quell oscillations in the (unused) outer loop portion of the ISS, I shorted the "PD+" and "PD-" signals from the (nonexistent) outer-loop diodes, and soldered in 47pf compensation capacitors in C92 and C220. This seems to have eliminated oscillations seen at TP41 and TP42. There's still something amiss at TP30 and maybe TP20. Otherwise, the ISS seems happy. I can turn the gain slider to +15dB without saturation (with the HEPA off), though there seems to be less light on the diode (~3.9V) than a week or two ago. |
210
|
Fri Dec 21 20:32:25 2007 |
tobin | Update | Photos | GigE camera |
I couldn't resist any longer: I plugged in the Prosilica GC 750 GigE camera and took it for a spin. This is the little CMOS camera which sends out video over gigabit ethernet.
There were no difficulties at all in getting it running. I just plugged in the power, plugged in ethernet, and put on a lens from Steve's collection. I downloaded the "Sample Viewer" from the Prosilica website and it worked immediately.
It turns out that "Kirk's" computer has not only a gigabit ethernet card, but a little gigabit ethernet switch. I plugged the camera into this switch. The frame rate is amazing. With the camera under fluorescent lights I thought I saw some wacky automatic gain control, but I think this ~10Hz flicker is aliasing of the 60 Hz room lighting.
I put the camera on the PSL table briefly and tried viewing the image from a laptop over the (54mbs) wireless network. This didn't work so well: you could get a couple frames out of the camera, but then the client software would complain that it had lost communications. It appeared that scattered 1064nm light did show up brightly on the camera image. There is a green ethernet cable currently stashed on the roof of the PSL that appears unused. We can try mounting the gigE CMOS cable in place of one of the CCD video cameras.
I did not try the Linux software.
The camera is currently set up at Kirk's desk, using the cool little tripod Rana got from CyberGuys.
This camera looks very promising! Also, in the test image attached below, a very unusual condition has been documented. |
Attachment 1: robs_desk.png
|
|
209
|
Thu Dec 20 21:58:28 2007 |
Andrey | Summary | Computer Scripts / Programs | Results for 2 previous XARM measurements have been added |
I attached results (plots) of yesterday's daytime and overnight measurements to the initial reports about those measurements.
These are ELOG entries # 201 and # 205. |
208
|
Thu Dec 20 21:57:34 2007 |
Andrey | Update | Computer Scripts / Programs | Measurements in XARM today |
Today at 2PM I started a program, it should change the suspension gains in the interval from 1.0 to 3.8 with the step 0.2. Estimated running time is till 3.30AM coming night.
Results will be reported on Friday.
BELOW: ADDITION MADE ON FRIDAY EVENING.
Due to some unforeseen circumstances, I was unable to add results on Friday. I have so far accelerometer spectra only, which I add to this ELOG entry.
I have files with the measurement results, and I will process them after Christmas and add to this ELOG entry. I might not be in the lab on Dec. 24 and 25. |
Attachment 1: Accelerom_ETMX.png
|
|
Attachment 2: Accelerom_ITMX.png
|
|
207
|
Thu Dec 20 19:10:03 2007 |
waldman | Update | OMC | Stressful reattachment of heater |
Photos may follow eventually, but for now here's the rundown. I scraped the heater clean of the thermal epoxy using a clean razor blade. Then I stuffed a small piece of lint free cloth in the OTAS bore and wrapped the OMC in tin foil. With a vacuum sucking directly from the face of the OTAS, I gently scraped the glue off the OTAS aluminum. I wiped both the OTAS and the heater down with an isoproponal soaked lint-free cloth. I put a thin sheen of VacSeal on the face of the heater, wiping off the excess from the edges with a cloth. Then I clamped the heater to the OTAS using 2" c-clamps from the tombstone back to the heater front, making sure the alignment of the OTAS was correct (connector on the absolute bottom, concentric with the OTAS outer diameter). I added a second clamp, then beaded the outside of the joint with a little bit extra VacSeal, just for kicks. I'll leave it covered at least overnight, and maybe for a day or two.
sam |
206
|
Thu Dec 20 19:05:34 2007 |
waldman | HowTo | OMC | HOWTO build front ends |
For instance, to build the TPT front end code.
- Save your file /cvs/cds/advLigo/src/epics/simLink/tpt.mdl
- go to /cvs/cds/advLIGO on the TPT machine
- do make clean-tpt tpt install-tpt
- do rm /cvs/cds/caltech/chans/daq/C2TPT.ini (this step is needed because the DAQ install code isn't quite right at the time of this writing.
- do make install-daq-tpt
- run starttpt to restart the tpt computer.
Enjoy. |
205
|
Thu Dec 20 02:04:09 2007 |
Andrey | Update | Computer Scripts / Programs | New overnight measurements in XARM and their results |
I ran in the daytime/evening time my program, changing the damping gains in suspension "position" degree of freedom for ETMX and ITMX
in the interval from 1.00 to 3.75 with the step 0.25 (see entry # 201).
Now I am running overnight (from 2AM till 9AM) the program changing the gains in the interval from 1.3 to 3.5 with the step 0.20,
12 X 12 = 144 experimental points. I started so late because I fell asleep after my Wednesday evening dinner, then woke up half an hour ago and hurried to the lab.
BELOW: RESULTS OF MEASUREMENTS WERE ADDED ON THURSDAY EVENING, DEC. 20.
All the meaning of the attachments 1-3, 4-6, 7-9, 10-11 is the same as in previous ELOG entries # 195, # 199, # 202, see in those entries which graph corresponds to which coordinate axes orientation. |
Attachment 1: RMS-08Hz-Top-View.png
|
|
Attachment 2: RMS-3Hz-Top-View.png
|
|
Attachment 3: RMS-broadband-Top-View.png
|
|
Attachment 4: RMS-08Hz-Side_View.png
|
|
Attachment 5: RMS-3Hz-Side_View.png
|
|
Attachment 6: RMS-broadband-Side_View.png
|
|
Attachment 7: RMS-08Hz-Q_I-Q_E-Axes.png
|
|
Attachment 8: RMS-3Hz-Q_I-Q_E-Axes.png
|
|
Attachment 9: RMS-broadband-Q_I-Q_E-Axes.png
|
|
Attachment 10: Accelerometer-ETMX.png
|
|
Attachment 11: Accelerometer-ITMX.png
|
|
204
|
Wed Dec 19 20:28:27 2007 |
Andrey | DAQ | PEM | Names for all 6 accelerometers have been changed |
I eventually changed the names for all 6 accelerometers (see my ELOG entry # 172 from Dec. 05 about my intent to do that).
I removed the word "BS" from their names,
and I changed the word combination "ACC_BS_EAST" in the old name for "ACC_ITMX" in the new name;
as well "ACC_BS_WEST" is now replaced by "ACC_ETMX".
(the reasoning behind such a change should become clear from my ELOG entry #172).
New accelerometer names are:
(note: there are no spaces (nowhere!) in the names of accelerometers, but ELOG replaces ": P" written without a space by a strange symbol )
C1 : PEM - ACC _ ETMX _ X ;
C1 : PEM - ACC _ ETMX _ Y ;
C1 : PEM - ACC _ ETMX _ Z ;
C1 : PEM - ACC _ ITMX _ X ;
C1 : PEM - ACC _ ITMX _ Y ;
C1 : PEM - ACC _ ITMX _ Z .
One can find them in "C1 : PEM - ACC" in Dataviewer.
|
203
|
Wed Dec 19 16:40:12 2007 |
steve | Update | SAFETY | laser safety glasses measured |
I measured the coarse transission at 1064nm of the 40m safety glasses today.
12 pieces of UVEX # LOTG-YAG/CO2 light green, all plastic construction, ADSORBANT
3 pieces of 6KG5, Scott colored filter glass type,
individual prescription glasses: alan, bob, ben, jay and steve
7 pieces of dual waveleght glasses
These glasses showed 0.00mW transmission out of 170mW Crysta Laser 1064 |
202
|
Wed Dec 19 16:07:37 2007 |
Andrey | Summary | Computer Scripts / Programs | Results of overnight measurements Tue/Wed night (entry #198) |
As indicated in ELOG entry 198, I was making overnight measurements during last night from Tuesday to Wednesday.
I was changing the suspension damping gain in ETMX and ITMX in "position" degree of freedom between values of 1.00 and 4.50 with the step 0.25.
Results for RMS of peaks (A) at 0.8Hz, (B) at about 3.0Hz and (C) in the range from 0.6Hz to 3.7Hz ("RMS in a broad interval") are given below:
I plotted three results for RMS in the abovementioned three intervals in three different ways:
1) view from the top in the axes (Q_{ITMX}+Q_{ETMX})/2 and (Q_{ITMX}-Q_{ETMX}) -> first three graphs (attachments 1 -3);
2) view from the side in the same sum- and difference-axes -> next three graphs (attachments 4-6);
3) view from the side in Q_{ITMX} and Q_{ETMX} axes -> next three graphs (attachments 7-9)
Attachments 10 and 11 show ratios of accelerometer signals at different times of the night/morning.
A little discussion about these graphs:
1) The areas of minima and of rapid growth are the same for all the measurements during all three nights.
2) Tonight there was a strange spike for the values of Q_{ETMX}=2.5 and Q_{ITMX}=4.0. I interpret that as an error of experiment.
3) On all the plots from all three nights there is a wide area of minimum on the plots for RMS at 0.8Hz and for "RMS in the broad interval",
and the graph for "RMS at 3Hz" indicates a clearer minimum in a localized area for Q_{ITMX}=2+-1, Q_{ETMX}=2+-1. Note that this area 2+-1
is included into the wide region of minimum for "RMS at 0.8Hz" and "RMS in a broad range".
Therefore, my guess at this stage is that we can choose the optimized value of suspension damping gains for both Q_{ITMX} and Q_{ETMX} somewhere
around 2+-1. I would like to make another overnight measurement (tonight) in that narrowed region with a small step to have more certainty.
By the way, I realized that I was a little bit careless and at some plots Q_I stands for {Q_ITMX}, and Q_E stands for Q_{ETMX}.
|
Attachment 1: RMS_08Hz_Top_view.png
|
|
Attachment 2: RMS_3Hz_Top_view.png
|
|
Attachment 3: RMS_broad_Top_view.png
|
|
Attachment 4: RMS_08Hz_Side_view.png
|
|
Attachment 5: RMS_3Hz_Side_view.png
|
|
Attachment 6: RMS_broadband_Side_view.png
|
|
Attachment 7: RMS_08Hz_Q_I-Q_E-axes.png
|
|
Attachment 8: RMS_3Hz_Q_I-Q_E-axes.png
|
|
Attachment 9: RMS_broadband_Q_I-Q_E-axes.png
|
|
Attachment 10: Accelerom_ETMX.png
|
|
Attachment 11: Accelerom_ITMX.png
|
|
201
|
Wed Dec 19 15:51:00 2007 |
Andrey | Update | Computer Scripts / Programs | Daytime measurements in XARM and their results |
I was making measurements in XARM for three different nights. All the results agree with each other (I will put the results from the last night soon).
Steve Vass recommended to me to compare those results with the daytime data, in order to see if there is a real necessity to run the scripts overnight or if daytime results will yield similar results.
XARM has been locked, and I am taking measurements today from 3.30PM till 11.30PM.
I will be changing the suspension damping gains in ETMX and ITMX "position" degrees of freedom in the interval from 1.0 to 3.75 with the step 0.25.
BELOW: RESULTS OF MEASUREMENTS WERE ADDED ON THURSDAY, DEC. 20.
All the meaning of the attachments 1-3, 4-6, 7-9, 10-11 is the same as in previous ELOG entries # 195, # 199, # 202, see in those entries which graph corresponds to which coordinate axes orientation. |
Attachment 1: RMS-08Hz-Top_View.png
|
|
Attachment 2: RMS-3Hz-Top_View.png
|
|
Attachment 3: RMS-broadband-Top_View.png
|
|
Attachment 4: RMS-08Hz-Side-View.png
|
|
Attachment 5: RMS-3Hz-Side_View.png
|
|
Attachment 6: RMS-broadband-Side_View.png
|
|
Attachment 7: RMS-08Hz-Q_I-Q_E-Axes.png
|
|
Attachment 8: RMS-3Hz-Side_View.png
|
|
Attachment 9: RMS-broadband-Side_View.png
|
|
Attachment 10: Accelerometer_ETMX.png
|
|
Attachment 11: Accelerometer_ITMX.png
|
|
200
|
Wed Dec 19 11:31:01 2007 |
steve | Omnistructure | PEM | aircond filter maintenance |
Jeff is working on all air condiontion units of the 40m lab
This we do every six months. |
Attachment 1: acfilters6m.jpg
|
|
199
|
Tue Dec 18 23:41:00 2007 |
Andrey | Summary | Computer Scripts / Programs | Results of Mon/Tue overnight measurements (entry #194) |
Here I inform our community about the results of the measurements of RMS values in XARM during the previous night from Monday to Tuesday (I announced those measurements in ELOG entry #194).
All the plots in today's report seem to agree well with the analogous plots from the night from Saturday to Sunday (those results are given in ELOG entry # 195).
All the intervals in which RMS have been calculated are the same as in yesterday's ELOG entry #195.
I plotted three results for RMS in the abovementioned three intervals in three different ways:
1) view from the top in the axes (Q_{ITMX}+Q_{ETMX})/2 and (Q_{ITMX}-Q_{ETMX}) -> first three graphs (attachments 1 -3);
2) view from the side in the same sum- and difference-axes -> next three graphs (attachments 4-6);
3) view from the side in Q_{ITMX} and Q_{ETMX} axes -> next three graphs (attachments 7-9, also attch. 12), above accelerometer spectra (attachments 10-11).
Also, I compared the ground noise level by comparing spectra of accelerometer signals at different times during that night. As a reminder, before my disease I installed one accelerometer near ITMX and another accelerometer near ETMX (see entries 161 and 172 in ELOG). The plots of ratios of accelerometer signals at different times (pairs of times that were used: 11PM and 2AM, 11PM and 5AM, 11PM and 8AM) are given below, see attachments 10-11. The program was running from 11PM on Monday till 9AM on Tuesday.
As I explained in the previous ELOG entry # 198, tonight I am taking experimental data in the narrowere interval from 1.00 to 4.50 with a smaller step 0.25. |
Attachment 1: RMS_08HZ_Top_View.png
|
|
Attachment 2: RMS_3HZ_Top_View.png
|
|
Attachment 3: RMS_broad_Top_View.png
|
|
Attachment 4: RMS_08HZ_Side_View.png
|
|
Attachment 5: RMS_3HZ_Side_View.png
|
|
Attachment 6: RMS_broad_Side_View.png
|
|
Attachment 7: RMS_08HZ_Q_E_Q_I_Axes.png
|
|
Attachment 8: RMS_3HZ_Q_E_Q_I_Axes.png
|
|
Attachment 9: RMS_broad_Q_E_Q_I_Axes.png
|
|
Attachment 10: Accelerometer_ITMX.png
|
|
Attachment 11: Accelerometer_ETMX.png
|
|
Attachment 12: RMS_broad_Q_E_Q_I_Axes.png
|
|
198
|
Tue Dec 18 23:27:36 2007 |
Andrey | Configuration | Computer Scripts / Programs | New overnight measurements (this night from Tue to Wed) |
I am making overnight measurements in XARM tonight.
This is the third night of measurements in XARM, but tonight I am scanning the narrower region between values of damping gain 1.00 and 4.50 with the smaller step 0.25. (for comparison, during two previous measurements the region was between 1.0 and 7.0 with the step 0.5).
I have relocked the XARM before the start of the measurements.
I started running the program at 9.30PM, and it should collect all the data by 9.00AM wednesday morning.
Below are explanations why I chose these different parameters for the interval and step:
I am going to put the results of previous night measurements into the next ELOG entry, and it we be pretty obvious from those graphs that results in XARM from the two previous (different) nights agree well with each other, and the approximate positions of minima and areas of "big growth" of the surfaces are pretty obvious from those graphs. It is clear that RMS are too big for the values of the damping gain bigger than 4.0, and that minima are somewhere near the values of 2.0. But those graphs were too rough to locate a somewhat precise value for the minima. Therefore, I am studying tonight the interval of gains between 1.00 and 4.50 with a smaller step.
A short note how I estimate time that is necessary to collect the experimental data.
there are 15 experimental points for each ETMX and ITMX suspension gains in the interval between 1.00 and 4.50 with the step 0.25. They are: 1.00, 1.25, 1.50, 1.75, 2.00, ..., 3.75, 4.00, 4.25, 4.50. As I am changing both ETMX and ITMX gains, I have an array of 15*15=225 elements.
It takes 3 minutes for each point to collect the data (I wrote the program that way). Therefore, the total time it takes to run the program is: 225*3=675 minutes, or 675/60=11.25 hours, almost 11 and a half hours. |
197
|
Tue Dec 18 21:31:31 2007 |
tobin | Update | PSL | ISS RIN |
My measurements of the ISS RIN via the SR785 and via the DAQ disagree considerably. The spectral shapes are very similar, however, so I expect that a constant factor is creeping in somewhere. Measurements taken at the PD DC monitor points using the SR785 attached. There is a lot of excess noise in the 300 Hz - 1 kHz region. |
Attachment 1: iss-rin.pdf
|
|
196
|
Tue Dec 18 16:50:35 2007 |
tobin | Update | SAFETY | uvex laser safety glasses defective |
A few days ago we noticed what appeared to be a blotched, speckled fracturing of the coating of the "UVEX" laser safety glasses. These are the glasses with "transparent" (reflective to 1064nm) lenses and white frames that we keep in a box on top of a filing cabinet in the control room. Today Steve measured the transmission of these glasses and found 80% transmission of 1064nm in several cases.
Do not use the white, transparent "uvex" laser safety glasses until further notice. Steve has hidden them away so that you won't be tempted.
Below is attached a photo of a bad lens. |
Attachment 1: bad-glasses.jpg
|
|
Attachment 2: bad-glasses-zoom.jpg
|
|
195
|
Tue Dec 18 00:51:39 2007 |
Andrey | Update | Computer Scripts / Programs | Results of Saturday overnight measurements |
As I indicated in the previous e-log entry (#194), I made overnight measurements in XARM in the night from Saturday to Sunday.
Root-mean-square values of the peaks in calibrated spectra were calculated, and I plotted them as functions of suspension gains in ITMX and ETMX "position" degrees of freedom.
More specifically, Q_ITMX means the value in the channel "C1:SUS-ITMX_SUSPOS_GAIN", while Q_ETMX means the value in the channel "C1:SUS-ETMX_SUSPOS_GAIN".
Root-mean-square values (RMS) were calculated during that night in three intervals:
1) around 0.8 HZ in the interval (0.6 Hz <-> 1.0 Hz);
2) around 3.0 Hz in the interval (2.0 Hz <-> 3.6 Hz);
3) in the broad interval from 0.6Hz to 3.6Hz.
I plotted three results for RMS in the abovementioned three intervals in three different ways:
1) view from the top in the axes (Q_{ITMX}+Q_{ETMX})/2 and (Q_{ITMX}-Q_{ETMX}) -> first three graphs (attachments 1 -3);
2) view from the side in the same sum- and difference-axes -> next three graphs (attachments 4-6);
3) view from the side in Q_{ITMX} and Q_{ETMX} axes -> next three graphs (attachments 7-9), above accelerometer spectra (attachments 10-11).
Also, I compared the ground noise level by comparing spectra of accelerometer signals at different times during that night. As a reminder, before my disease I installed one accelerometer near ITMX and another accelerometer near ETMX (see entries 161 and 172 in ELOG). The plots of ratios of accelerometer signals at different times (pairs of times that were used: 12AM and 3AM, 12AM and 6AM, 12AM and 9AM) are given below, see attachments 10-11.
Tomorrow I will try to compare the results with the second measurements that are being taken tonight. |
Attachment 1: RMS_08Hz_top_view.png
|
|
Attachment 2: RMS_3Hz_top_view.png
|
|
Attachment 3: RMS_broad_top_view.png
|
|
Attachment 4: RMS_08Hz_Qsum-Qdiff-axes.png
|
|
Attachment 5: RMS_3Hz_Qsum-Qdiff-axes.png
|
|
Attachment 6: RMS_broad_Qsum-Qdiff-axes.png
|
|
Attachment 7: RMS_08Hz_Qaxes.png
|
|
Attachment 8: RMS_3Hz_Qaxes.png
|
|
Attachment 9: RMS_broad_Qaxes.png
|
|
Attachment 10: Accel_ITMX.png
|
|
Attachment 11: Accel_ETMX.png
|
|
194
|
Mon Dec 17 23:42:08 2007 |
Andrey | Configuration | Computer Scripts / Programs | Overnight measurements in X-arm |
I am making overnight measurements this night (from Monday to Tuesday) in XARM.
The X-arm is now locked, and the values for suspension damping gain will be changed in the interval from 1 to 7 with the step 0.5 in both ITMX and ETMX.
This is the second, repeated measurement. The results of the first measurement from Saturday to Sunday night will be reported in the separate ELOG entry (sorry, I did not make an ELOG entry on Saturday evening about running the program overnight).
The very first attempt to run the script in the night from Thursday to Friday was not successful. |
193
|
Mon Dec 17 11:47:13 2007 |
alberto | Update | Electronics | an alternative design for the RFAM monitor's filter at 33Mhz |
Since the Butterworth turned out o be rather wide-band, I tried an other configuration for the 33 MHz filter. Attached are the simulated transfer function and the measured. As one can see, the measured peak is much broader than expected. |
Attachment 1: RFSim99-33MHz.png
|
|
Attachment 2: RF99-SimmButterworthPrototype.png
|
|
Attachment 3: RFSim99-33MHz-TFplot.png
|
|
192
|
Sun Dec 16 16:52:40 2007 |
dmass | Update | Computers | Computer on the end Fixed |
I had Mike Pedraza look at the computer on the end (tag c21256). It was running funny, and turns out it was a bad HD.
I backed up the SURF files as attachments to their wiki entries. Nothing else seemed important so the drive was (presumably) swapped, and a clean copy of xp pro was installed. The username/login is the standard one.
Also - that small corner of desk space is now clean, and it would be lovely if it stayed that way. |
191
|
Thu Dec 13 23:56:02 2007 |
Andrey | Configuration | Computer Scripts / Programs | Overnight measurements |
After my disease (fever, vomitting, nose problem, overall weakness) I returned to LIGO today for the first time after the weekend, and I am running the script for the XARM-measurements over this night.
So, suspension dumping gains should undergo changes in the interval from 1 to 10 in both ITMX and ETMX.
XARM has been of course locked.
I started running the script for the first time at about 10PM, but I realized after an hour and a half that my step of gain increase 0.2 was too shallow, too small to execute my program during one night. Therefore, I needed to terminate the program, change my program so that it increases the gain with increment 0.5, not 0.2, and started it again around midnight.
Going home.
P.S. The red pump that I borrowed from the lab (Steve's pump?) is back at its previous place. The tire-worker tells me that I absolutely need to change all four tires for almost 500 dollars. I regret a lot about that huge money loss. |
190
|
Thu Dec 13 12:05:36 2007 |
alberto | Omnistructure | Electronics | The new Butterworth seems to work quite well |
It works better probably because of the small inductors I'm using this time.
The peak is at 30 MHz because I didn't have the precise elements to get 33.
The bandwidth and the Q could be improved by adding one or two more order to the filter and trying to better match the low-pass' resonant frequency with the high-pass'.
Also I have to see if it could work at 166 and 199 MHz as well. |
Attachment 1: TF_New_Butterworth_12-Nov-2007_TF.png
|
|
Attachment 2: Bultervverth2.png
|
|
189
|
Wed Dec 12 22:24:48 2007 |
tobin | Frogs | PEM | weather station |
I poked at the weather station briefly this evening.
* There's almost nothing in the elog about it.
* It exists. It is located on the North wall, just north of the beam splitter.
* It seems to be displaying reasonable data for the indoors, but nothing for the outdoor sensors.
* c1pem didn't seem to be starting up (couldn't telnet into it, etc). I altered its startup file and reset it several times, and eventually it came to life.
* the weather station has a serial cable that goes all the way to c1pem. I plugged it in.
* however, the Weather.st program complains "NO COMM"--it gets no data from the weather station
* The next thing to do is to plug in a laptop to that serial cable and see if the weather station can be convinced to talk. |
188
|
Wed Dec 12 16:22:22 2007 |
alberto | Omnistructure | Electronics | LC filter for the RF-AM monitor circuit |
In the LC configuration (see attached schematic) the resonant frequency is tuned to one of the peak of our RF-AM monitor and it is amplified by a factor equal to the Q of the filter. As I wrote in one of the last elog entries, we would like amplifications of about 10-30 dB in order to have negligible couplings. Such values are obtained only with small capacitances (few or less pF). The drawback is relatively large inductance (uH or more) which has inevitably low Self Resonant Frequencies (SRF - the resonant frequencies of the RLC circuit usually associated with an actual inductor - ~ MHz). Even before, one limit is also the input impedance of the RF amplifier. Quality factors > 1 require megaohms, far from the 50 ohms in the MiniCircuit amplifiers I’m using now. So, if we plan to use these even for the final design of the circuit, we have to abandon the LC configuration.
For this same reason the only way I could get the expected responses from my several test boards was with a 10 megaohm input probe (see attachment for the measurement with and without probe). Assuming that impedance, I found these as the best trade-offs between the attenuation requirements and the values of the inductors for respectively the peaks at 33, 66,133, 166,199 MHz:
26uH, 6.6u, 20u, 73u, 16u
If we could find inductor with these values and high SRF the configuration should work. The problem is I couldn’t find any. Above a few uH they all seem to have SRF ~ MHz.
That is why I switched to the Butterworth. This should work despite the input impedance of the amplifier and with much smaller inductances. I made a totally new test circuit, with surface mount components. I think I still have to fix some things in the measurements but (this time I got rid of the simulator I was using earlier and designed a new configuration with new values from the Horowitz’s tables) it seems I have the expected peaks. More soon. |
Attachment 1: TF_LC_filter_10pF_1.8uH_scope_probe.png
|
|
Attachment 2: TF_LC_filter_10pF_1.8mH_no_probe.png
|
|
Attachment 3: LC_filter_schematic.png
|
|
187
|
Mon Dec 10 20:35:59 2007 |
tobin | Configuration | Computer Scripts / Programs | autolocking scripts |
I added this tidbit of csh code to the MZ autolocker to prevent multiple copies from running (on one computer):
if (`pgrep lockMZ | wc -l` > 1) then
echo lockMZ is already running!
exit
endif Similarly, here's some bash code that does something similar; I'll add it to the other autolocker scripts:
if
pgrep `basename $0` | grep -v $$ > /dev/null
then
echo Another copy of this program is already running. Exiting!
exit 1
fi This code searches for all processes with the same name as this script ($0) and then use grep to exclude (-v) the current process ID ($$). |
186
|
Mon Dec 10 19:08:03 2007 |
tobin | Configuration | PSL | MZ |
The MZ seems finicky today--it keeps unlocking and relocking.
I've temporarily blocked one of the MZ arms while I work on the ISS. |
185
|
Mon Dec 10 18:42:20 2007 |
tobin | Update | PSL | ISS RIN script |
I wrote a script to measure the ISS RIN. The script uses the "labca" interface (described in an earlier entry) to read and twiddle EPICS settings and mDV to get DAQ data. The script measures open loop RIN, closed loop RIN at each of several gain slider settings, and dark noise. The dark noise is obtained by misaligning (unlocking) the PMC. The script also compares the whitened and unwhitened spectra for an open loop measurement and performs a fit of a simple pole to find the dewhitening filter.
This is all very exciting, but I don't quite believe the results, since the closed loop RIN seems to bottom out at 2e-7/rtHz regardless of the gain slider setting.
Sample output attached. The script may be found at scripts/PSL/ISS/rin.m. |
Attachment 1: rin-20071210-1831.pdf
|
|
184
|
Mon Dec 10 13:54:26 2007 |
rob | HowTo | Computer Scripts / Programs | Don't blame the Matlab compiler |
For human error. We should be careful to only run the compiler outside the mDV directory (thus placing the _mcr outside of the range the addpath command in the mdv_config files). Or maybe there's a smarter solution... |
183
|
Fri Dec 7 19:14:30 2007 |
tobin | Update | PSL | ISS dark noise - ground loop enlightenment |
My alleged 60 Hz harmonics were all from a ground loop created by connecting the SR785 ground to the ISS circuit ground; they disappeared when I set the SR785 input to "floating ground." doh!
I modified the ISS PD's to have a 100 ohm resistor in series with the output (in place of 20 ohms). The diodes are again in place on the table, ready for action. |
182
|
Fri Dec 7 18:31:30 2007 |
tobin | Update | Computer Scripts / Programs | compiled matlab hoses itself |
Addendnum. The reason the linemon_mcr command was in the path was because of the user issuing the command "addpath(genpath(pwd))" where genpath(D) "returns a path string starting in D, plus, recursively, all the subdirectories of D."
The Matlab compiler is still bad, however. |
181
|
Fri Dec 7 18:28:30 2007 |
tobin | Update | Computer Scripts / Programs | compiled matlab hoses itself |
Andrey pointed out to me that some matlab functions in the Signal Processing Toolbox were dying with errors. Looking into the .m file (identified using the "which" command), I was surprised to see binary garbage rather than glistening, clear Matlab prose. Then I noticed the directory in which it was finding the .m file:
>> which decimate
/cvs/cds/caltech/apps/mDV/extra/linetrack_c_mcr/toolbox/signal/signal/decimate.m See that "linetrack_c_mcr" directory? This is what is generated when a "compiled" (grumble) Matlab program is run--it decompresses itself into a subdirectory containing weird semi-compiled binary .m files. Unfortunately this is somehow getting incorporated into the matlab path. (I assume there is something in mDV that says "put all subdirectories into the path.")
I hate the Matlab compiler. |
180
|
Fri Dec 7 14:14:48 2007 |
rob | Metaphysics | Computer Scripts / Programs | tdsread problems on Solaris |
tdsread has developed a strange new illness, whereby it cannot read EPICS values from two subsystems at once (e.g., getting an LSC and SUS value simultaneously). I thought this might have something to with the fact that both losepics and iscepics are running on the same box,
but the same thing happens with IOO EPICS records, so that's not the culprit.
This is new behaviour, and it's only happening on the solaris machines. I suspect some ENV/cshrc juju has caused it, as the tdsread executable is the same one from April, and I don't think our EPICS infrastructure has changed otherwise. In the near term we can either try running the scripts on linux, or modify the IFO scripts to not do these types of calls. |