ID |
Date |
Author |
Type |
Category |
Subject |
457
|
Sun Apr 27 22:57:15 2008 |
ajw | DAQ | Computers | br40m? |
Quote: |
The testpoint manager (which runs on fb40m) crashed this afternoon. Upon re-starting it, I found there was a rogue dtt process on op440m and also a daqd daemon running on br40m. One or both of these caused the tpman to crash. br40m is the frame broadcaster, which is never used here as we don't run DMT. I killed the daqd process there.
The way to find if there is a rogue process is to watch the output to the console from the tpman when you start it:
Allocate new TP handle 56 by 131.215.113.203
Allocate new TP handle 57 by 131.215.113.203
Allocate new TP handle 58 by 131.215.113.203
Allocate new TP handle 59 by 131.215.113.203
Allocate new TP handle 60 by 131.215.113.203
Allocate new TP handle 61 by 131.215.113.203
Allocate new TP handle 62 by 131.215.113.203
Allocate new TP handle 63 by 131.215.113.203
Allocate new TP handle 64 by 131.215.113.203
Allocate new TP handle 65 by 131.215.113.203
Allocate new TP handle 66 by 131.215.113.203
Allocate new TP handle 67 by 131.215.113.203
Allocate new TP handle 68 by 131.215.113.203
If you see something like this, with a new TP handle being allocated every few seconds, you need to log in to the corresponding host and kill whatever process has run away. |
I *think* Alex is responsible for the daqd daemon running on br40m (he set up some new stuff recently, a data concentrator and broadcaster); I'll make sure he sees this post. |
459
|
Tue Apr 29 21:09:12 2008 |
rana | DAQ | CDS | FE Filters |
These are new FE filters for downsampling and upsampling. We will be going from native hardware sampling rates of 64k down to 32k, 16k, and 2k.
The attached plot shows these filters. They are 3dB ripple, 40 dB stopband, 4th order elliptic filters in which I have moved the zeros around
into good places (e.g. to the Nyquist frequency).
I'm also attaching the .txt file containg the filter coefficients and the design strings. The filters are called x2, x4, and x32, for the
D2, D4, and D32 downsampling, respectively. |
Attachment 1: fefilters.jpg
|
|
Attachment 2: fefilters.txt
|
# FILTERS FOR ONLINE SYSTEM
#
# Computer generated file: DO NOT EDIT
#
# MODULES ULYAW
#
################################################################################
### ULYAW ###
################################################################################
# SAMPLING ULYAW 65536
... 28 more lines ...
|
583
|
Fri Jun 27 15:20:52 2008 |
rob | DAQ | LSC | .ini file change |
I removed C1:LSC-XARM_CTRL from the frames and added C1:LSC-CARM_ERR |
640
|
Mon Jul 7 13:58:37 2008 |
Eric, josephb | DAQ | PEM | Using unused PEM channels to test camera code |
Joe and I have taken control of the EPICS channels C1:PEM-Stacis_EEEX_geo and C1:PEM-Stacis_EEEY_geo since we heard that they are no longer in use. We are currently
using them to test the ability for the Snap camera code to read and write from EPICS channels. Thus, the information being written to these channels is completely unrelated
to their names or previous use. This is only temporary; we'll create our own channels for the camera code shortly (probably within the next couple of days).
- Eric |
660
|
Fri Jul 11 20:16:01 2008 |
Eric | DAQ | Cameras | Taking data from the GC 750 Camera |
Mafalda has been set up with a background process to constantly take data from the GC 750 camera (at the end of the x-arm) for the weekend. This camera will otherwise be inoperable until then.
In the small chance that this slows either Mafalda or the network to a crawl, the process to kill should have PID 26265. |
671
|
Tue Jul 15 10:09:42 2008 |
Eric | DAQ | Cameras | Did anyone kill the picture taking process on Mafalda? |
Did anyone kill the process on Mafalda that was taking pictures of the end mirror of the x-arm last Friday? I need to know whether or not it crashed of its own accord. |
673
|
Tue Jul 15 11:47:56 2008 |
Jenne | DAQ | PEM | Accelerometer channels in ASS Adapt MEDM screen |
Jenne, Sharon
We have traced which accelerometers correspond to which channels in the C1ASS_TOP MEDM screen.
Accelerometer Channel
------------- --------------------------
MC1-X C1:ASS-TOP_PEM_2_ADAPT_IN1
MC1-Y C1:ASS-TOP_PEM_3_ADAPT_IN1
MC1-Z C1:ASS-TOP_PEM_4_ADAPT_IN1
MC2-X C1:ASS-TOP_PEM_5_ADAPT_IN1
MC2-Y C1:ASS-TOP_PEM_6_ADAPT_IN1
MC2-Z C1:ASS-TOP_PEM_7_ADAPT_IN1
SEISMOMETER C1:ASS-TOP_PEM_1_ADAPT_IN1 |
684
|
Wed Jul 16 17:36:51 2008 |
John | DAQ | PSL | FSS input offset |
I changed the nominal FSS input offset to 0 from 0.3. Tolerance remains unchanged at +/-0.05. |
700
|
Fri Jul 18 19:43:55 2008 |
Yoichi | DAQ | Computers | PSL fast channels cannot be read by dataviewer |
At this moment only the PSL fast channels have trouble.
Rob restarted fb40m, c1IOVME, but no effect. |
826
|
Mon Aug 11 19:09:28 2008 |
Jenne | DAQ | PEM | Seismometer DAQ is being funny |
While looking at the Ranger seismometer's output to figure out what our max typical ground motion is, Rana and I saw that the DAQ output is at a weird level. It looks like even though the input to the DAQ channel is being saturated, the channel isn't outputing as many counts as expected to Dataviewer.
Sharon and I checked that the output of the seismometer looks reasonable - sinusoidal when I tap on the seismometer, and the the output of the SR560 (preamp) is also fine, and not clipping. If I stomp on the floor, the output of the SR560 goes above 2V (to about 3V ish), so we should be saturating the DAQ, and getting the max number of counts out. However, as you can see in the first figure, taken when I was tapping the seismometer, the number of counts at saturation is well beneath 32768counts. (16 bit machine, so the +-2V of the DAQ should have a total range of 65536. +2V should correspond to +32768counts.) The second figure shows 40 days of seismometer data. It looks like we saturate the DAQ regularly.
I did a check of the DAQ using an HP6236B power supply. I sent in 1V, 2V and 2.2V (measuring the output of the power supply with a 'scope), and measured the number of counts output on the DAQ.
Input Voltage [V] | Counts on Dataviewer | Expected counts from 16 bit machine
|
1 | 18983 | 16384
|
2 | 29331 | 32768
|
2.2 | 29347 | 32768
|
I'm not sure why the +1V output more than the expected number of counts (unless I mis-measured the output from the power supply).
Moral of the story is...when the DAQ is saturated, it is not outputting the expected number of counts. To be explored further tomorrow... |
Attachment 1: SeisDAQ.png
|
|
Attachment 2: SeisData.png
|
|
917
|
Wed Sep 3 19:09:56 2008 |
Yoichi | DAQ | Computers | c1iovme power cycled |
When I tried to measure the sideband power of the FSS using the scan of the reference cavity, I noticed that the RC trans. PD signal was not
properly recorded by the frame builder.
Joe restarted c1iovme software wise. The medm screen said c1iovme is running fine, and actually some values were recorded by the FB.
Nonetheless, I couldn't see flashes of the RC when I scanned the laser frequency.
I ended up power cycling the c1iovme and run the restart script again. Now the signals recorded by c1iovme look fine.
Probably, the DAQ boards were not properly initialized only by the software reset.
I will re-try the sideband measurement tomorrow morning. |
1028
|
Mon Oct 6 12:45:41 2008 |
Alberto | DAQ | LSC | C1LSC in coma |
Alberto, Joe,
The C1LSC medm screen is frozen and the C1LSC computer is down. We tried to reboot and to restart it first turning off the power and then just rebooting remotely. None of them worked. We check whether any of the cable was unplugged but they were ok. Also all the led turned on to green after rebooting.
Trying to reboot we get the following error message: init_module: device or resource busy.
We called Alex who first suggested to check all the connection and then to swap the timing cable between two Pentek boards but the computer was still down.
It is possible that the board is dead. Alex and Rolf are going to look into this problem and for any spare board.
by now we can't lock any DOF of the IFO. |
1029
|
Mon Oct 6 16:41:33 2008 |
Alberto | DAQ | LSC | C1LSC in coma |
Quote: | Alberto, Joe,
The C1LSC medm screen is frozen and the C1LSC computer is down. We tried to reboot and to restart it first turning off the power and then just rebooting remotely. None of them worked. We check whether any of the cable was unplugged but they were ok. Also all the led turned on to green after rebooting.
Trying to reboot we get the following error message: init_module: device or resource busy.
We called Alex who first suggested to check all the connection and then to swap the timing cable between two Pentek boards but the computer was still down.
It is possible that the board is dead. Alex and Rolf are going to look into this problem and for any spare board.
by now we can't lock any DOF of the IFO. |
Alex, Rob, Alberto,
Alex replaced the Pentek board used by C1LSC with a spare one that they had at the Wilson house. That fixed the DMA failure but since the board had a channel broken, one of the channels (POY) was still not available.
Looking at the wiring diagram of the ASC crate, we found that one of the Pentek boards in it was actually not used by anything and thus available to replace the bad one in LSC. We switched the two boards so that now the one that Alex installed is mounted in the ASC crate and it is connected to the cable labeled 1x2-ASC 6.
C1LSC is up again and all the channels in the C1LSC screen, including POY, now seem to be working properly. |
1066
|
Wed Oct 22 09:42:41 2008 |
Alberto | DAQ | Computers | c1iool0 rebooted and MC autolocker restarted |
This morning I found the MC unlocked. The MC-Down script didn't work because of network problems in communicating with scipe7, a.k.a. c1iool0. Telneting to the computer was also impossible so I power cycled it from its key switch. The first time it failed so I repeated it a second time and then it worked.
Yoichi then restarted c1iovme. It was also necessary to restart the MC autolocker script according to the following procedure:
- ssh into op440m
- from op440m, ssh into op340m
- restart /cvs/cds/caltech/scripts/scripts/MC/autolockMCmain40 |
1114
|
Tue Nov 4 17:58:42 2008 |
Alberto | DAQ | PSL | MC temperature sensor |
I added a channel for the temperature sensor on the MC1/MC3 chamber: C1:PSL-MC_TEMP_SEN.
To do that I had to reboot the frame builder. The slow servo of the FSS had to get restarted, the reference cavity locked and so the PMC and MZ. |
1124
|
Fri Nov 7 18:38:19 2008 |
Alberto | DAQ | PSL | MC temperature sensor hooked up |
Alberto, Rana,
we found that the computer handling the signals from ICS-110B was C1IOVME so we restarted it. We changed the name of the channel to C1:PEM_TEMPS and the number to 16349. We tracked it up to the J14 connector of the DAQ.
We also observed the strange thing that both of the differential pairs on J13 are read by the channle. Also, if you connect a 50 Ohm terminator to one of the pairs, the signal even get amplified.
(The name of the channel is PEM-MC1_TEMPS) |
1130
|
Wed Nov 12 11:14:59 2008 |
Caryn | DAQ | PSL | MC temp sensor hooked up incorrectly |
MC Temperature sensor was not hooked up correctly. It turns out that for the 4 pin LEMO connections on the DAQ like J13, J14, etc. the channels correspond to horizontal pairs on the 4 pin LEMO. The connector we used for the temp sensor had vertical pairs connected to each BNC which resulted in both the differential pairs on J13 being read by the channel.
To check that a horizontal pair 4 pin LEMO2BNC connector actually worked correctly we unlocked the mode cleaner, and borrowed a connector that was hooked up to the MC servo (J8a). We applied a sine wave to each of the BNCs on the connector, checked the J13 signal and only one of the differential pairs on J13 was being read by the channel. So, horizontal pairs worked. |
1143
|
Tue Nov 18 13:28:08 2008 |
Caryn | DAQ | IOO | new channel for MC drum modes |
Alberto has added a channel for the Mode Cleaner drum modes.
C1:IOO-MC_DRUM1
sample rate-2048
chnum-13648 |
1228
|
Wed Jan 14 15:53:32 2009 |
steve | DAQ | PSL | MC temperature sensor |
Quote: | I added a channel for the temperature sensor on the MC1/MC3 chamber: C1:PSL-MC_TEMP_SEN.
To do that I had to reboot the frame builder. The slow servo of the FSS had to get restarted, the reference cavity locked and so the PMC and MZ. |
Where is this channel? |
1246
|
Thu Jan 22 14:38:41 2009 |
caryn | DAQ | PSL | MC temperature sensor |
Quote: |
Quote: | I added a channel for the temperature sensor on the MC1/MC3 chamber: C1:PSL-MC_TEMP_SEN.
To do that I had to reboot the frame builder. The slow servo of the FSS had to get restarted, the reference cavity locked and so the PMC and MZ. |
Where is this channel? |
That's not the name of the channel anymore. The channel name is PEM-MC1_TEMPS. It's written in a later entry. |
1349
|
Tue Mar 3 11:39:50 2009 |
Osamu | DAQ | Computers | 2 PCs in Martian |
Kiwamu and I brought 2 SUPER MICRO PCs from Willson house into 40m.
Both PCs are hooked up into Martian network. One is named as bscteststand for BSC which has been set up by Cds people and another one is named kami1 for temporary use for CLIO which is a bland new, no operating installed PC. This bland new PC will be returned Cds or 40m once another new PC which we will order within several days arrives.
IP address for each machine is 131.215.113.83 and 131.215.113.84 respectively.
We have installed CentOS5.2 into the new PC. |
1381
|
Mon Mar 9 23:55:38 2009 |
Osamu | DAQ | Computers | bscteststand and kami1 outside martian |
This morning there was a confliction of tpman running on fb40m and kami1. Alex fixed it temporary but Rana suggested it was better to move both PCs outside martian. We moved both PCs physically to the control room and connected to general network with a local router. I believe it won't conflict anymore but if you guess these PC might have trouble please feel free to shutdown.
Today's work summary:
*connected expansion chassis to bscteststand
*obtained signals on dataviewer, dtt for both realtime and past data on bscteststand with 64kHz timing signal
Questions:
Excitation channels are not shown, only "other" is shown.
qts.mdl should run with 16kHz but 16kHz timing causes a slow speed on dataviewer and failing data aquisition on dtt. We are using 64kHz timing but is it really correct? |
1407
|
Mon Mar 16 15:19:52 2009 |
Osamu | DAQ | Electronics | SR785 |
I borrowed SR785 to measure AA, AI noise and TF. |
1417
|
Sun Mar 22 23:16:41 2009 |
rana | DAQ | Computer Scripts / Programs | tpman restart |
Could get testpoints but couldn't start excitations. Restarted tpman on daqawg. Works now.
Still no log file.  |
1528
|
Tue Apr 28 12:55:57 2009 |
Caryn | DAQ | PEM | Unplugged Guralp channels |
For the purpose of testing out the temperature sensors, I stole the PEM-SEIS_MC1X,Y,Z channels.
I unplugged Guralp NS1b, Guralp Vert1b, Guralp EW1b cables from the PEM ADCU(#10,#11,#12) near 1Y7 and put temp sensors in their place (temporarily). |
1540
|
Sat May 2 16:34:31 2009 |
caryn | DAQ | PEM | Guralp channels plugged back in |
I plugged the Guralp cables back into the PEM ADCU
Guralp NS1b ---> #11
Guralp Vert1b --->#10
Guralp EW1b --->#12 |
1643
|
Tue Jun 2 23:53:12 2009 |
pete | DAQ | Computers | reset c1susvme1 |
rob, alberto, rana, pete
we reset this computer, which was out of sync (16384 in the FE_SYNC field instead of 0) |
1661
|
Mon Jun 8 18:22:27 2009 |
Alberto | DAQ | LSC | Added PD11 I amd Q slow channels |
I just added two slow channels to C0EDCUEPICS to monitor the input of PD11. The names are:
[C1:LSC-PD11_I_INMON]
[C1:LSC-PD11_Q_INMON] |
1733
|
Sun Jul 12 20:06:44 2009 |
Jenne | DAQ | Computers | All computers down |
I popped by the 40m, and was dismayed to find that all of the front end computers are red (only framebuilder, DAQcontroler, PEMdcu, and c1susvmw1 are green....all the rest are RED).
I keyed the crates, and did the telnet.....startup.cmd business on them, and on c1asc I also pushed the little reset button on the physical computer and tried the telnet....startup.cmd stuff again. Utter failure.
I have to pick someone up from the airport, but I'll be back in an hour or two to see what more I can do. |
1735
|
Mon Jul 13 00:34:37 2009 |
Alberto | DAQ | Computers | All computers down |
Quote: |
I popped by the 40m, and was dismayed to find that all of the front end computers are red (only framebuilder, DAQcontroler, PEMdcu, and c1susvmw1 are green....all the rest are RED).
I keyed the crates, and did the telnet.....startup.cmd business on them, and on c1asc I also pushed the little reset button on the physical computer and tried the telnet....startup.cmd stuff again. Utter failure.
I have to pick someone up from the airport, but I'll be back in an hour or two to see what more I can do.
|
I think the problem was caused by a failure of the RFM network: the RFM MEDM screen showed frozen values even when I was power recycling any of the FE computers. So I tried the following things:
- resetting the RFM switch
- power cycling the FE computers
- rebooting the framebuilder
but none of them worked. The FEs didn't come back. Then I reset C1DCU1 and power cycled C1DAQCTRL.
After that, I could restart the FEs by power recycling them again. They all came up again except for C1DAQADW. Neither the remote reboot or the power cycling could bring it up.
After every attempt of restarting it its lights on the DAQ MEDM screen turned green only for a fraction of a second and then became red again.
So far every attempt to reanimate it failed. |
1736
|
Mon Jul 13 00:53:50 2009 |
Alberto | DAQ | Computers | All computers down |
Quote: |
Quote: |
I popped by the 40m, and was dismayed to find that all of the front end computers are red (only framebuilder, DAQcontroler, PEMdcu, and c1susvmw1 are green....all the rest are RED).
I keyed the crates, and did the telnet.....startup.cmd business on them, and on c1asc I also pushed the little reset button on the physical computer and tried the telnet....startup.cmd stuff again. Utter failure.
I have to pick someone up from the airport, but I'll be back in an hour or two to see what more I can do.
|
I think the problem was caused by a failure of the RFM network: the RFM MEDM screen showed frozen values even when I was power recycling any of the FE computers. So I tried the following things:
- resetting the RFM switch
- power cycling the FE computers
- rebooting the framebuilder
but none of them worked. The FEs didn't come back. Then I reset C1DCU1 and power cycled C1DAQCTRL.
After that, I could restart the FEs by power recycling them again. They all came up again except for C1DAQADW. Neither the remote reboot or the power cycling could bring it up.
After every attempt of restarting it its lights on the DAQ MEDM screen turned green only for a fraction of a second and then became red again.
So far every attempt to reanimate it failed.
|
After Alberto's bootfest which was more successful than mine, I tried powercycling the AWG crate one more time. No success. Just as Alberto had gotten, I got the DAQ screen's AWG lights to flash green, then go back to red. At Alberto's suggestion, I also gave the physical reset button another try. Another round of flash-green-back-red ensued.
When I was in a few hours ago while everything was hosed, all the other computer's 'lights' on the DAQ screen were solid red, but the two AWG lights were flashing between green and red, even though I was power cycling the other computers, not touching the AWG at the time. Those are the lights which are now solid red, except for a quick flash of green right after a reboot.
I poked around in the history of the curren and old elogs, and haven't found anything referring to this crazy blinking between good and bad-ness for the AWG computers. I don't know if this happens when the tpman goes funky (which is referred to a lot in the annals of the elog in the same entries as the AWG needing rebooting) and no one mentions it, or if this is a new problem. Alberto and I have decided to get Alex/someone involved in this, because we've exhausted our ideas. |
1752
|
Wed Jul 15 17:18:24 2009 |
Jenne | DAQ | Computers | DAQAWG gone, now back |
Yet again, the DAQAWG flipped out for an unknowable reason. In order of restart activities listed on the Wiki, I keyed the crate and nothing really happened, then I hit the physical reset button and nothing happened, and then I did the 'telnet....vmeBusReset', and a couple minutes later, it was all good again. |
1769
|
Tue Jul 21 17:01:18 2009 |
pete | DAQ | DAQ | temp channel PEM-PETER_FE |
I added a temporary channel, to input 9 on the PEM ADCU. Beware the 30, 31, and 32 inputs. I tried 32 and it only gave noise.
|
1831
|
Wed Aug 5 07:33:04 2009 |
steve | DAQ | Computers | fb40m is down |
|
1832
|
Wed Aug 5 09:25:57 2009 |
Alberto | DAQ | Computers | fb40m is up |
FB40m up and running again after restarting the DAQ. |
1836
|
Wed Aug 5 15:33:05 2009 |
rob, alberto | DAQ | General | can't get trends |
We can't read minute trends from either Dataviewer or loadLIGOData from before 11am this morning.
fb:/frames>du -skh minute-trend-frames/
106G minute-trend-frames
So the frames are still on the disk. We just can't get them with our usual tools (NDS).
Trying to read 60 days of minute trends from C1:PSL-PMC_TRANSPD yields:
Connecting to NDS Server fb40m (TCP port 8088)
Connecting.... done
258.0 minutes of trend displayed
read(); errno=9
read(); errno=9
T0=09-06-06-22-34-02; Length=5184000 (s)
No data output.
Trying to read 3 seconds of full data works.
Second trends are readable after about 4am UTC this morning, which is about 9 pm last night.
|
1841
|
Thu Aug 6 09:22:17 2009 |
Alberto | DAQ | General | can't get trends |
Quote: |
We can't read minute trends from either Dataviewer or loadLIGOData from before 11am this morning.
fb:/frames>du -skh minute-trend-frames/
106G minute-trend-frames
So the frames are still on the disk. We just can't get them with our usual tools (NDS).
Trying to read 60 days of minute trends from C1:PSL-PMC_TRANSPD yields:
Connecting to NDS Server fb40m (TCP port 8088)
Connecting.... done
258.0 minutes of trend displayed
read(); errno=9
read(); errno=9
T0=09-06-06-22-34-02; Length=5184000 (s)
No data output.
Trying to read 3 seconds of full data works.
Second trends are readable after about 4am UTC this morning, which is about 9 pm last night.
|
Yesterday Alex started transferring the data records to the new storage unit. That prevented us from accessing the trends for a fe hours.
The process had been completed and now we can read the trends again. |
2365
|
Tue Dec 8 10:20:33 2009 |
Alberto | DAQ | Computers | Bootfest succesfully completed |
Alberto, Kiwamu, Koji,
this morning we found the RFM network and all the front-ends down.
To fix the problem, we first tried a soft strategy, that is, we tried to restart CODAQCTRL and C1DCUEPICS alone, but it didn't work.
We then went for a big bootfest. We first powered off fb40m, C1DCUEPICS, CODAQCTRL, reset the RFM Network switch. Then we rebooted them in the same order in which we turned them off.
Then we power cycled and restarted all the front-ends.
Finally we restored all the burt snapshots to Monday Dec 7th at 20:00. |
2874
|
Mon May 3 19:21:43 2010 |
Alberto | DAQ | Environment | Boot fest |
[Alberto, Koji, Rana]
The RFM network failed today. We had to reboot the frame builder anf restart all the front end following the instructions for the "Nuclear Option".
Burt-restoring to May 1st at 18:07, or April 30 18:07 made c1sosvme crash. We had to reset the front ends again and restore to April 15th at 18:07 in order to make everything work.
Everything seems fine again now. |
3038
|
Wed Jun 2 18:36:20 2010 |
valera | DAQ | CDS | Noise generators in LSP |
Alex wrote a new code to implement LSP noise generator. The code is based on 64 bit random number generator from Numerical Recipes 3rd ed ch 7.1 (p 343).
Joe made two instances in the LSP model.
The attached plot shows the spectra and coherence of two generators. The incoherence is ~1/Navg - statistically consistent with no coherence. |
Attachment 1: noisegenerators.pdf
|
|
3090
|
Sat Jun 19 17:31:48 2010 |
rana | DAQ | CDS | Excess Noise in C1:IOO-MC_DRUM1 fixed by reboot |
I was getting an excess noise in the C1:IOO-MC_DRUM1 channel - it was a flat spectrum of 10 cts/rHz (corresponding to 600 uV/rHz).
I tried a few things, but eventually had to power cycle the crate with c1iovme in order to recover the standard ADC noise level of 3x10^-3 cts/rHz with a 1/sqrt(f) knee at 10 Hz.
I checked the gain of the channel by injecting a 2 Vpp sine wave at 137.035 Hz. 2Vpp as measured on a scope gives 31919 cts instead of the expected 32768, giving a 2.5% error from what we would have naively calculated.
Even so, the noise in this channel is very surprisingly good: 0.003 / (31919 / 2) = 187 nV /rHz. The best noise I have previously seen from an ICS-110B channel is 800 nV/rHz. What's going on here? |
3117
|
Thu Jun 24 18:47:26 2010 |
Frank | DAQ | IOO | VME crate rebooted |
we had to reboot the IOO VME crate right before lunch as the DAQ wasn't working correct meaning showing no real signals anymore, only strange noise. The framebuilder and everything else was working fine at that time.
- The channel used for the phase noise measurement stopped showing any useful signal right after midnight, so all the other IOO-MC signals.
- The data taken with those channels showed something like a 140 counts or so of steady offset with something which looked like the last bit fluctuating.
- Whatever signal we connected to the input it didn't change at all, floating/shorted input, sine wave etc.
- the other channels for the MC which we checked showed the same strange behaviour
As the other channels showed the same effect we decided to reboot the crate and everything was fine afterwards. |
173
|
Thu Dec 6 15:21:59 2007 |
alberto | Frogs | Electronics | RF Transfer Function of Stiff Aluminum Wires |
Transfer function of 3cm long Aluminum wires and of 3cm stranded wires |
Attachment 1: TF_3cm_stiff_wires.amplitude.png
|
|
Attachment 2: DSC_0225compressed.JPG
|
|
Attachment 3: TF_3cm_stranded_wires.amplitude.png
|
|
189
|
Wed Dec 12 22:24:48 2007 |
tobin | Frogs | PEM | weather station |
I poked at the weather station briefly this evening.
* There's almost nothing in the elog about it.
* It exists. It is located on the North wall, just north of the beam splitter.
* It seems to be displaying reasonable data for the indoors, but nothing for the outdoor sensors.
* c1pem didn't seem to be starting up (couldn't telnet into it, etc). I altered its startup file and reset it several times, and eventually it came to life.
* the weather station has a serial cable that goes all the way to c1pem. I plugged it in.
* however, the Weather.st program complains "NO COMM"--it gets no data from the weather station
* The next thing to do is to plug in a laptop to that serial cable and see if the weather station can be convinced to talk. |
340
|
Sun Feb 24 10:51:58 2008 |
tf | Frogs | Environment | 40m in phdcomics? |
 |
581
|
Fri Jun 27 09:20:15 2008 |
steve | Frogs | PEM | dust particle count is up & alarm handler is on |
This 3 years plot show the trend of seasons.
When outside air quality goes bad ( 0.5 micron > 1 million ) the lab follows.
I will demonstrate this effect with a 4th of July fire works calibration.
Let's do not forget the construction activity next door either.
The alarm handler is busy:
It's sound level were reset to a modest level yesterday.
It would be nice to change the alarm sound so it can play Wagner:Der Ring des Nibelungen:
Das Rheingold, Die Walkure & Siegfried and Gotterdammerung
or something more appropriate than the present frog call
1, half micron count is climbing ( it's close to 16k now )
2, MZ refl signal is too high
3, MC lenght servo LO is too |
Attachment 1: dust3y.jpg
|
|
666
|
Mon Jul 14 10:57:00 2008 |
Koji | Frogs | Environment | Someone at 40M sent LHO water of life |
Someone at the 40m sent Mike@LHO a pound of peets coffee with the name of Koji Arai.
It was a good surprise! Thanks, we will enjoy it!
I will return to Pasadena next week. See you then. |
877
|
Mon Aug 25 11:43:55 2008 |
Yoichi | Frogs | IOO | MC REFL PD cable had been disconnected through out the weekend |
Most of my morning was wasted by the MC REFL PD cable, which was disconnected on the generic LSC PD interface board.
I know who did this. *ME*. When I pulled out the MC board, which is sitting next to the PD interface, on Friday, I must have
disconnected the PD cable accidentally. The connector of the PD cable (D-Sub) does not have screws to tighten and easily comes off.
I wrote this entry to warn other people of this potential problem. |
976
|
Mon Sep 22 15:02:45 2008 |
rana | Frogs | Treasure | Mantis found outside the 40m door at night |
|
Attachment 1: mantis.JPG
|
|
1268
|
Tue Feb 3 15:01:38 2009 |
Alberto | Frogs | Computers | megatron slow? |
I notice that Megatron is slower than any other computer in running code that invokes optickle or looptickle (i.e. three times slower than Ottavia). Even without the graphics.
Has anyone ever experienced that? |