ID |
Date |
Author |
Type |
Category |
Subject |
16461
|
Tue Nov 9 16:55:52 2021 |
Ian MacMillan | Summary | Computer Scripts / Programs | SUS Plant Plan for New Optics |
[Ian, Tega]
We have moved c1sim computer from the test stand to the server rack in the office area. (see picture)
It is connected to the general campus network. Through the network switch at the top of the rack. This switch seeds the entire Martian network.
Test to show that I am not lying:
- you can ping it or ssh into it at
controls@131.215.114.116
Using the same password as before. Notice this is not going through the nodus network.
- It also has a different beginning of the IP addresses. Martian network IP addresses start with 191.168.113
c1sim is now as connected to the 40m network as my mom's 10-year-old laptop.
unfortunately, I have not been able to get the x2go client to connect to it. I will have to investigate further. It is nice to have access to the GUI of c1sim occasionally.
|
Attachment 1: IMG_8107.JPG
|
|
16462
|
Tue Nov 9 18:05:03 2021 |
Ian MacMillan | Summary | Computer Scripts / Programs | SUS Plant Plan for New Optics |
[Ian, Tega]
Now that the computer is in its new rack I have copied over the filter two files that I will use in the plant and the controller from pianosa:/opt/rtcds/caltech/c1/chans to the docker system in c1sim:/home/controls/docker-cymac/chans. That is to say, C1SUP.txt -> X1SUP.txt and C1SUS.txt -> X1SUS_CP.txt, where we have updated the names of the plant and controller inside the txt files to match our testing system, e.g. ITMX -> OPT_PLANT in plant model and ITMX -> OPT_CTRL in the controller and the remaining optics (BS, ITMY, PRM, SRM) are stripped out of C1SUS.txt in order to make X1SUS_CP.txt.
Once the filter files were copied over need to add them to the filters that are in my models to do this I run the commands:
$ cd docker-cymac
$ eval $(./env_cymac)
$ ./login_cymac
# cd /opt/rtcds/tst/x1/medm/x1sus_cp
# medm -x X1SUS_OPT_PLANT_TM_RESP.adl
see this post for more detail
Unfortunately, the graphics forwarding from the docker is not working and is giving the errors:
arg: X1SUS_OPT_PLANT_TM_RESP.adl
locateResource 'X1SUS_OPT_PLANT_TM_RESP.adl'
isNetworkRequest X1SUS_OPT_PLANT_TM_RESP.adl
canAccess('X1SUS_OPT_PLANT_TM_RESP.adl', 4) = 0
can directly access 'X1SUS_OPT_PLANT_TM_RESP.adl'
isNetworkRequest X1SUS_OPT_PLANT_TM_RESP.adl
locateResource(X1SUS_OPT_PLANT_TM_RESP.adl...) returning 1
Error: Can't open display:
This means that the easiest way to add the filters to the model is through the GUI that can be opened through X2go client. It is probably easiest to get that working. graphics forwarding from inside the docker is most likely very hard.
unfortunately again x2go client won't connect even with updated IP and routing. It gives me the error: unable to execute: startkde. Going into the files on c1sim:/usr/bin and trying to start startkde by myself also did not work, telling me that there was no such thing even though it was right in front of me.
|
16466
|
Mon Nov 15 15:12:28 2021 |
Ian MacMillan | Summary | Computer Scripts / Programs | SUS Plant Plan for New Optics |
[Ian, Tega]
We are working on three fronts for the suspension plant model:
- Filters
- We now have the state-space matrices as given at the end of this post. From these matrices, we can derive transfer functions that can be used as filter inputs. For a procedure see HERE. We accomplish this using Matlab's built-in
ss(A,B,C,D); function. then we make it discrete using c2d(sys, 1/f); this gives us our discrete system running at the right frequency. We can get the transfer functions of either of these systems using tf(sys);
- from there we can copy the transfer functions into our photon filters. Tega is working on this right now.
- State-Space
- We have our matrices as listed at the end of this post. With those compiled into a discrete system in MatLab we can use the code Chris made called
rtss.m to convert this system into a .c file and a .h file.
- from there we have moved those files under the userapps folder in the docker system. then we added a c-code block to our .mdl model for the plant and pointed it at the custom c file we made. See section 7.2 of T080135-v10
- We have done all this and this should implement a custom state-space function into our .mdl file. the downside of this is that to change our SS model we have to edit the matrices we can't edit this from an medm screen. We have to recompile every time.
- Python Check
- This python check is run by Raj and will take in the state-space matrices which are given then will take transfer functions along all inputs and outputs and will compare them to what we have from the CDS model.
Here are the State-space matrices:

A few notes: If you want the values for these parameters see the .yml file or the State-space model file. I also haven't been able to find what exactly this s is in the matrices.
UPDATE [11/16/21 4:26pm]: I updated the matrices to make them more general and eliminate the "s" that I couldn't identify.
The input vector will take the form:

where x is the position, theta is the pitch, phi is the yaw, and y is the y-direction displacement
|
16469
|
Tue Nov 16 17:29:49 2021 |
Ian MacMillan | Summary | Computer Scripts / Programs | SUS Plant Plan for New Optics |
[Ian, Tega]
Updated A, B, C, D matrices for the state-space model to remove bugs in the previous estimate of the system dynamics. Updated the last post to represent the current matrixes.
We used MatLab to get the correct time-series filter coefficients in ZPK format and added them to the filters running in the TM_RESP filter matrix.
Get the pos-pos transfer function from the CDS model. Strangely, this seems to take a lot longer than anticipated to generate the transfer function, even though we are mainly probing the low-frequency behavior of the system.
For example, a test that should be taking approximately 6 minutes is taking well over an hour to complete. This swept sine (results below) was on the low settings to get a fast answer and it looks bad. This is a VERY basic system it shouldn't be taking this long to complete a Swept sine TF.
Noticed that we need to run eval $(./env_cymac) every time we open a new terminal otherwise CDS doesn't work as expected. Since this has been the source of quite a few errors already, we have decided to put it in the startup .bashrc script.
loc=$(pwd)
cd ${HOME}/docker-cymac/
eval $(./env_cymac)
cd ${loc}
|
Attachment 1: x_x_TF1.pdf
|
|
16477
|
Thu Nov 18 20:00:43 2021 |
Ian MacMillan | Summary | Computer Scripts / Programs | SUS Plant Plan for New Optics |
[Ian, Raj, Tega]
Here is the comparison between the results of Raj's python model and the transfer function measurement done on the plant model by Tega and me.
As You can see in the graphs there are a few small spots of disagreement but it doesn't look too serious. Next we will measure the signals flowing through the entire plant and controller.
For a nicer (and printable) version of these plots look in the zipped folder under Plots/Plant_TF_Individuals.pdf |
Attachment 1: Final_Plant_Testing.zip
|
16478
|
Mon Nov 22 16:38:26 2021 |
Tega | Summary | Computer Scripts / Programs | SUS Plant Plan for New Optics |
[Tega, Ian]
TODO
1. Investigate cross-coupling btw the various degrees of freedom (dof) - turn on noise for each dof in the plant model and measure the transfer function of the other dofs.
2. Get a closed-loop transfer function using noise injection and give a detailed outline of the procedure in elog - IN1/IN2 for each TM_RESP filter while the others are turned off.
3. Derive analytic model of the closed-loop transfer functions for comparison.
4. Adapt control filters to fit optimized analytical solutions. |
16615
|
Mon Jan 24 17:10:25 2022 |
Tega | Summary | Computer Scripts / Programs | SUS Plant Plan for New Optics |
[Ian, Tega]
Connected the New SUS screens to the controller for the simplant model. Because of hard-coded links in the medm screen links, it was necessary to create the following path in the c1sim computer, where the new medm screen files are located:
/opt/rtcds/userapps/trunk/sus/c1/medm/templates/NEW_SUS_SCREENS
We noticed a few problems:
1. Some of the medm files still had C1 hard coded, so we need to replace them with $IFO instead, in order for the custom damping filter screen to be useful.
2. The "Load coefficient" button was initially blank on the new sus screen, but we were able to figure out that the problem came from setting the top-level DCU_ID to 63.
medm -x -macro "IFO=X1,OPTIC=OPT_CTRL,DCU_ID=63" SUS_SINGLE_OVERVIEW.adl
[TODO]
Get the data showing the controller damping the pendulum. This will involve tweaking some gains and such to fine-tune the settings in the controller medm screen. Then we will be able to post some data of the working controller.
[Useful aside]
We should have a single place with all the instructions that are currently spread over multiple elogs so that we can better navigate the simplant computer. |
Attachment 1: Screen_Shot_2022-01-24_at_5.33.15_PM.png
|
|
16626
|
Thu Jan 27 16:40:57 2022 |
Tega | Summary | Computer Scripts / Programs | SUS Plant Plan for New Optics |
[Ian, Paco, Tega]
Last night we set up the four main matrices that handle the conversion between the degrees of freedom bases and the sensor bases. We also wrote a bash script to automatically set up the system. The script sets the four change of bases matrices and activates the filters that control the plant. this script should fully set up the plant to its most basic form. The script also turns off all of the built-in noise generators.
After this, we tried damping the optic. The easiest part of the system to damp is the side or y motion of the optic because it is separate from the other degrees of freedom in both of the bases. We were able to damp that easily. in attachment 1 you can see that the last graph in the ndscope screen the side motion of the optic is damped. Today we decided to revisit the problem.
Anyways, looking at the problem with fresh eyes today, I noticed the in pit2pit coupling has the largest swing of all the plant filters and thought this might be the reason why the inputs (UL,UR,LR,LL) to the controller was hitting the rails for pit DoF. I reduce the gain of the pit2pit filter then slowly increased it back to one. I also reduced the gain in the OSEM input filter from 1 to 1/100. The attached image (Attachment2) is the output from this trial. This did not solve the problem. The output when all OSEM input filter gain set to one is shown in Attachment2.
We will try to continue to tweak the coefficients. We are probably going to ask Anchal and Paco to sit down with us and really hone in on the right coefficients. They have more experience and should be able to really get the right values. |
Attachment 1: simplant_control_1.png
|
|
Attachment 2: simplant_control_0.png
|
|
16645
|
Thu Feb 3 17:15:23 2022 |
Tega | Summary | Computer Scripts / Programs | SUS Plant Plan for New Optics |
Finally got the SIMPLANT damping to work following Rana's suggestion to try damping one DoF at a time, woo-hoo!
At first, things didn't look good even when we only focus on the POS DoF. I then noticed that the input value (X1:SUS-OPT_PLANT_TM_RESP_1_1_IN1) to the plant was always zero. This was odd bcos it meant the control signal was not making its way to the plant. So I decided to look at the sensor data
(X1:SUS-OPT_PLANT_COIL_IN_UL_OUTPUT, X1:SUS-OPT_PLANT_COIL_IN_UR_OUTPUT, X1:SUS-OPT_PLANT_COIL_IN_LR_OUTPUT, X1:SUS-OPT_PLANT_COIL_IN_LL_OUTPUT)
that adds up via the C2DOF matrix to give the POS DoF and I noticed that these interior nodes can take on large values but always sum up to zero because the pair (UL, LL) was always the negative of (UR,LR). These things should have the same sign, at least in our case where only the POS DoF is excited, so I tracked the issue back to the alternating (-,+,-,+,-) convention for the gains
(X1:SUS-OPT_CTRL_ULCOIL_GAIN, X1:SUS-OPT_CTRL_URCOIL_GAIN, X1:SUS-OPT_CTRL_LRCOIL_GAIN, X1:SUS-OPT_CTRL_LLCOIL_GAIN, X1:SUS-OPT_CTRL_SDCOIL_GAIN)
of the Coil Output filters used in the real system, which we adopted in the hopes that all was well. Anyways, I changed them all back to +1. This also means that we need to change the sign of the gain for the SIDE filter, which I have done also (and check that it damps OK). I decided to reduce the magnitude of the SIDE damping from 1 to 0.1 so that we can see the residuals since the value of -1 quickly sends the error to zero. I also increased the gain magnitude for the other DoF to 4.
When looking at the plot remember that the values actually represent counts with a scaling of 2^15 (or 32768) from the ADC. I switched back to the original filters on FM1 (e.g. pit_pit ) without damping coefficients present in the FM2 filter (e.g. pit_pit_damp).
FYI, Rana used the ETMY suspension MEDM screen to illustrate the working of the single suspension to me and changed maybe POS and PITCH gains while doing so.
Also, the Medify purifier 'replace filter' indicator issue occurred bcos the moonlight button should have been pressed for 3 seconds to reset the 'replace filter' indicator after filter replacement. |
Attachment 1: Screen_Shot_2022-02-03_at_8.23.07_PM.png
|
|
16654
|
Wed Feb 9 14:34:27 2022 |
Ian | Summary | Computer Scripts / Programs | SUS Plant Plan for New Optics |
Restarted the C1sim machine at about 12:30 to help diagnose a network problem. Everything is back up and running |
Attachment 1: SummaryMdemScreen.png
|
|
8747
|
Tue Jun 25 22:50:12 2013 |
rana | Update | SUS | SUS Screens generation problems? |

From the ALS overview screen, opening up the ETMX and ETMY screens gives these white fields. The PV info indicates that the blank fields were made with some macro variable substitution that didn't work well.
Why are these different from the SUS screens I get from the sitemap? |
8152
|
Sun Feb 24 00:14:28 2013 |
Manasa | Update | SUS | SUS Summary |
I tried to fix the alarms for sensors on the SUS summary screen. I checked earlier elogs and found the setSensors.py script.
I received errors while running the script and pianosa was refused connection to nds. Yuta suspects problems with the lib directory.
Jamie! Can you fix this? |
8154
|
Sun Feb 24 17:54:34 2013 |
rana | Update | SUS | SUS Summary |
I asked John Z to talk with Jamie and then install a new NDS2 server software for us. Jamie may know if this happened or was foiled by the linux1 RAID failure.
In any case, our pyNDS stuff ought to be able to talk to NDS2 or our old NDS1 stuff, I hope. |
5318
|
Mon Aug 29 16:27:34 2011 |
Manuel | Configuration | SUS | SUS Summary Screen |
I edited the C1SUS_SUMMARY.adl file and set the channels in alarm mode to show the values in green, yellow and red according to the values of the thresholds (LOLO, LOW, HIGH, HIHI)
I wrote a script in python, which call the command ezcawrite and ezcaread, to change the thresholds one by one.
You can call this program with a button named "Change Thresholds one by one" in the menu come down when you click the ! button.
I'm going to write another program to change the thresholds all together. |
12255
|
Wed Jul 6 19:36:45 2016 |
Koji | Update | General | SUS Vmon |
I wanted to know what this Vmon exactly is. D010001 is telling us that the Vmon channels are HPFed with fc=30Hz (Attachment 1). Is this true?
I checked the quiscent noise spectrum of the ITMX UL coil output (C1:SUS-ITMX_ULCOIL_OUT ) and the corresponding VMON (C1:SUS-ITMX_ULVmon ). (Attachment 2 Ref curves). I did not find any good coherence. So the nominal quiscent Vmon output is carrying no useful information.
Question: How much do we need to excite the coil output in order to see any meaningful signal?
As I excite the ITMX UL coil (C1:SUS-ITMX_ULCOIL_EXC ) with uniform noise of 100-300 counts below 0.3Hz, I eventually could see the increase of the power spectrum and the coherence (Attachment 2). Below 0.1 Hz the coherence was ~1 and the transfer function was measured to be -75dB and flat. But wait, why is the transfer function flat?
In fact, if I inject broadband noise to the coil, I could increase the coil output and Vmon at the same time without gaining the coherence. (Attachment 3). After some more investigation, I suspect that this HPF is diabled (= bypassed) and aliasing of the high freq signal is causing the noise in Vmon.
In order to check this hypothesis, we need to visit the board. |
Attachment 1: HPF.png
|
|
Attachment 2: 160706_ITMX_VMON2.pdf
|
|
Attachment 3: 160706_ITMX_VMON1.pdf
|
|
12268
|
Thu Jul 7 15:23:39 2016 |
ericq | Update | General | SUS Vmon |
Based on Koji's observation of a flat TF, it seems more likely the Vmon channels are looking at the path I've highlighted in green (named "EPICS V Mon"), rather than the path in red (named "DAQ Mon") that Koji initially suspected. This path still lacks any AA for the 16Hz EPICS sampling.

|
12269
|
Thu Jul 7 16:05:55 2016 |
Koji | Update | General | SUS Vmon |
Ah, thanks. That makes sense. In that case, we should remove the texts "30Hz HPF" from the suspension screens.
Now we just need AA LPFs for these channels, or hook them up to the RT system. |
4812
|
Mon Jun 13 19:26:42 2011 |
Jamie, Joe | Configuration | CDS | SUS binary IO chassis 2 and 3 moved from 1X5 to 1X4 |
While preping 1X4 for installation of c1lsc, we removed some old VME crates that were no longer in use. This freed up lots of space in 1X4. We then moved the SUS binary IO chassis 2 and 3, which plug into the 1X4 cross-connect, from 1X5 into the newly freed space in 1X4. This makes the cable run from these modules to the cross connect much cleaner. |
4814
|
Tue Jun 14 09:24:36 2011 |
steve | Configuration | Photos | SUS binary IO chassis 2 and 3 moved from 1X5 to 1X4 |
Quote: |
While preping 1X4 for installation of c1lsc, we removed some old VME crates that were no longer in use. This freed up lots of space in 1X4. We then moved the SUS binary IO chassis 2 and 3, which plug into the 1X4 cross-connect, from 1X5 into the newly freed space in 1X4. This makes the cable run from these modules to the cross connect much cleaner.
|
Are we keeping these? |
Attachment 1: P1070891.JPG
|
|
Attachment 2: P1070893.JPG
|
|
6182
|
Mon Jan 9 23:52:15 2012 |
kiwamu | Update | CDS | SUS channels not accessible from dataviewer |
[John / Kiwamu]
We found that some of the suspensions channels (for example C1:SUS-BS_POS_IN1 and etc) were not accessible from dataviewer for some reasons.
So far it seems none of the channels associated with c1sus are accessible from dataviewer. |
4780
|
Thu Jun 2 16:23:42 2011 |
Jamie | Update | SUS | SUS control models updated to use new sus_single_control library part |
A new library part was made for the single suspension controller (it was originally made from the c1scx controller), using the following procedure:
- Opened c1scx model (userapps/trunk/sus/c1/models/c1scx)
- Cut ETMX subsystem block out of SUS subsystem
- Pasted ETMX block into new empty library, and renamed it C1_SUS_SINGLE_CONTROL
- Tweaked names of inputs, and generally cleaned up internals (cosmetically)
- Saved library to: userapps/trunk/sus/c1/models/lib/sus_single_control.mdl
Once the new sus_single_control library part was made and the library was committed to the cds_user_apps repo, I replaced all sus controller subsystems with this new part, in:
- c1scx
- c1scy
- c1sus (x5 for each vertex mass)
All models were rebuild, installed, and tested, and everything seems to be working fine. |
12315
|
Wed Jul 20 13:58:55 2016 |
Steve | Update | SUS | SUS damping out of vac chamber |
Cheater cable to be used in clean room pitch gluing alingment.
Satelite amp needs to be there.
Atm 2-3, The ETMs suspension damping cable are connected at the end racks. All others go to 1X5
Atm 4-5, The other end of this cable in the high cable tray at 1X3 as shown. We'll disconnect the shorty and move the end to ETMX ( or any sus at 1X5 )
|
Attachment 1: ETMXrack.jpg
|
|
Attachment 2: fromETMX-satBox.jpg
|
|
Attachment 3: susDampingSatboxCab.jpg
|
|
Attachment 4: susDampingSatboxCabl.jpg
|
|
5461
|
Mon Sep 19 15:41:48 2011 |
Jenne | Update | SUS | SUS diag stuff... just so I remember what I'm doing |
The following optics were kicked:
ETMX
Mon Sep 19 15:39:44 PDT 2011
1000507199 |
5471
|
Mon Sep 19 22:47:44 2011 |
Jenne | Update | SUS | SUS diag stuff... just so I remember what I'm doing |
The last person out tonight should run the following scripts:
In Matlab:
/opt/rtcds/caltech/c1/scripts/SUS/peakFit/writeMultiSUSinmat.m
In command line:
/opt/rtcds/caltech/c1/scripts/SUS/freeswing all
Then in the morning, someone should do a BURT restore to early today (to get the default matricies back), and also restore the watchdogs.
Thanks!
|
5485
|
Tue Sep 20 16:45:09 2011 |
Jenne | Update | SUS | SUS diag stuff... just so I remember what I'm doing |
Has the Q been checked? Still in progress...
Optic |
POS |
PIT |
YAW |
SIDE |
ITMX |
done |
done |
done |
done |
ITMY |
done |
done |
fine?? |
done |
ETMX |
done |
done |
done |
done |
ETMY |
done |
done |
done |
done |
BS |
done |
done |
done |
done |
PRM |
done |
done |
done |
done |
SRM |
done |
done |
done |
done |
MC1 |
|
|
|
|
MC2 |
|
|
|
|
MC3 |
|
|
|
|
So, update as of 6:17pm: I have tuned the damping gains for all IFO optics. Everything is good, except for ITMY Yaw. It's probably fine, the optic damps okay, but it doesn't look like a nice clean ringdown. I haven't taken the time to go back and look at it again.
I have to go to a dinner, but later (probably in the morning, so I don't disturb evening locking) I'll check the MC Qs. |
5493
|
Wed Sep 21 00:34:29 2011 |
rana | Update | SUS | SUS diag stuff... just so I remember what I'm doing |
ETMX was ringing up when it was mis-aligned for Y arm locking. I restored the input matrix to something more diagonal and its now damping again. Needs more work before we can use the calculated matrix. |
11569
|
Thu Sep 3 19:52:24 2015 |
rana | Summary | SUS | SUS drift monitor |
Since Andrey's SUS Drift mon screen back in 2007, we've had several versions which used different schemes and programming languages. Diego made an update back in January.
Today I added his stuff to the SVN since it was lost in the NFS disks somewhere. Its in SUS/DRIFT_MON/.
Since we've been updating our userapps directory recently to pull in the screens and scripts from the sites, we also got a copy of the Thomas Abbott drift mon stuff which is better (Diego actually removed the yellow/red functionality as part of the 'upgrade'), but more complicated. For now we have the old one. I updated the good values with all optics roughly aligned just a few minutes ago.
|
Attachment 1: 07.png
|
|
2901
|
Sun May 9 20:02:23 2010 |
rana | Configuration | SUS | SUS filters deleted again to reduce CPU load on c1susvme2 again |
On Friday, I deleted a bunch of filters from the c1susvme2 optics' screens (MC1,2,3 + SRM) so as to reduce the CPU load and keep it from going bonkers.
This first plot shows the CPU trend over the last 40 days and 40 nights. As you can see the CPU_LOAD has dropped by 1 us since I did the deleting.
 
In the second plot (on the right) you can see the same trend but over 400 days and nights. Of course, we hope that we throw this away soon, but until then it will be nice to have the suspensions be working more often. |
16997
|
Wed Jul 13 12:49:25 2022 |
Paco | Summary | SUS | SUS frozen |
[Paco, JC, Yuta]
This morning, while investigating the source of a burning smell, we turned off the c1SUS 1X4 power strip powering the sorensens. After this, we noticed the MC1 refl was not on the camera, and in general other vertex SUS were misaligned even though JC had aligned the IFO in the morning to almost optimum arm cavity flashing. After a c1susaux modbusIOC service restart and burt restore, the problem persisted.
We started to debug the sus rack chain for PRM since the oplev beam was still near its alignment so we could use it as a sensor. The first weird thing we noticed was that no matter how much we "kicked" PRM, we wouldn't see any motion on the oplev. We repeatedly kicked UL coil and looked at the coil driver inputs and outputs, and also verified the eurocard had DC power on which it did. Somehow disconnecting the acromag inputs didn't affect the medm screen values, so that made us suspicious that something was weird with these ADCs.
Because all the slow channels were in a frozen state, we tried restarting c1susaux and the acromag chassis and this fixed the issue. |
5766
|
Sun Oct 30 23:03:37 2011 |
SUS_Diagonalizer | Update | SUS | SUS input matrix diagonalization complete (EXAMPLE) |
New SUS input matrix diagonalization complete. Matrices have been written to the frontend. Summaries for each optic can be viewed below.
(THIS IS AN EXAMPLE---no new matrices have been written.) |
Attachment 1: MC1.png
|
|
Attachment 2: MC2.png
|
|
Attachment 3: MC3.png
|
|
Attachment 4: ETMX.png
|
|
Attachment 5: ETMY.png
|
|
Attachment 6: ITMX.png
|
|
Attachment 7: ITMY.png
|
|
Attachment 8: PRM.png
|
|
Attachment 9: SRM.png
|
|
Attachment 10: BS.png
|
|
5775
|
Tue Nov 1 13:46:03 2011 |
Zach | Update | SUS | SUS input matrix diagonalizer REMOVED from crontab |
It turns out that nodus doesn't know how to NDS2, so I can't run diagAllSUS as a cron job on nodus. To further complicate things, no other machines can run the elog utility, so I am going to have to do something shifty... |
5770
|
Mon Oct 31 14:06:16 2011 |
Zach | Update | SUS | SUS input matrix diagonalizer added to crontab |
I actually tried to do this last night, but I was getting a terminal error from nodus. Jamie told me to just manually redefine the TERM variable and it would work. So, I have added kickAll and diagAllSUS to controls@nodus's crontab:
nodus:~>crontab -l
0 5 * * * /opt/rtcds/caltech/c1/scripts/backup/rsync.backup
0 7 * * * /opt/rtcds/caltech/c1/scripts/backup/check_backup.sh
0 17 * * 0 /cvs/cds/caltech/users/jenne/LIGOX/LIGOX_Pizza_Reminders.sh
0 8 * * 0 /cvs/cds/rtcds/caltech/c1/scripts/SUS/peakFit/kickAll
0 18 * * 0 /cvs/cds/rtcds/caltech/c1/scripts/SUS/peakFit/diagAllSUS
Again, their functionality should be checked before this is allowed to run on Sunday!
|
15836
|
Tue Feb 23 23:12:37 2021 |
Koji | Summary | SUS | SUS invacuum wiring |
This is my current understanding of the in-vacuum wiring:
1. Facts
- We have the in-air cable pinout. And Gautam recently made a prototype of D2100014 custom cable, and it worked as expected.
- The vacuum feedthrough is a wall with the male pins on the both sides. This mirrors pinout.
- On the in-vacuum cable stand (bracket), the cable has a female connector.
2. From the above facts, the in-vacuum cable is
- DSUB25 female-female cable
- There is no pinout mirroring
Accuglass has the DSUB25 F-F cable off-the-shelf. However, this cable mirrors the pinout (see the datasheet on the pdf in the following link)
https://www.accuglassproducts.com/connector-connector-extension-cable-25-way-female
3. The options are
- ask Accuglass to make a twisted version so that the pinout is not mirrored.
or
- combine Accuglass female-male cable (https://www.accuglassproducts.com/connector-connector-extension-cable-25-way-femalemale) and a gender changer (https://www.accuglassproducts.com/gender-adapter-25d)
4. The length will be routed from the feedthrough to the table via the stacks like a snake to be soft. So, it will require some extra length.
5. Also, the Accuglass cables don't have a flap and holes to fix the connector to a cable post (tower). If we use a conventional 40m-style DSUB25 post (D010194), it will be compatible with their cables. But this will not let us use a DSUB25 male connector to mate. In the future, the suspension will be upgraded and we will need an updated cable post that somehow holds the connectors without fastening the screws... |
Attachment 1: SOS_OSEM_cabling.pdf
|
|
6365
|
Tue Mar 6 16:17:36 2012 |
Jenne | Update | SUS | SUS matrix diagonalization status |
Has default inmat:
PRM, ITMX
Has fancy inmat:
BS, ITMY, SRM (but side is non-fancy), ETMX, ETMY, MC1, MC2, MC3
So it's likely that the MICH problems (giganto 1Hz peak) Keiko and Kiwamu were seeing last night had to do with ITMX having the non-optimized input matrix. I'll try to figure out where the data from the last freeswing test is, and put in a fancy diagonalized matrix. |
9088
|
Thu Aug 29 17:25:50 2013 |
Jamie | Update | SUS | SUS medm screen upgrade |
Rana asked me to look at the SUS MEDM screen upgrade situation, and provide an upgrade prescription. Unfortunately there not really a simple prescription that can be used, since our configuration diverges quite a bit from what's at the sites. But here's what I can say:
It looks like we already have the beginnings of an upgrade in place, so I say we just run with that. The new screens are in:
/opt/rtcds/userapps/release/sus/c1/medm/new
The primary screen is:
/opt/rtcds/userapps/release/sus/c1/medm/new/OVERVIEW.adl
This seems to be a copy of the site ASC_TIPTILT screens. (In fact I think I remember putting this here). I went ahead and did some ground work to make it easier to get these new screens into place.
- I cleaned up all the channel name prefixes so that at least the channel prefixes will resolve to our SUS channels.
- I made a link from the sitemap with some of the correct macros to fill some things in appropriately: "IFO SUS/NEW ETMX"
- I fixed the names to the sub-screens, so that it correctly opens the correct sub-screens (although the macros seem to not be passed correctly)
At this point someone needs to just go through and fix all the channel names to match ours, and tweak the screen to our needs (there's no side OSEM, for instance). The subscreens need to be cleaned up as well.
sed replace string
If there is a specific string you want to replace every instance of in the screen, you can do that easily from the command line like this:
sed -i 's/OLD/NEW/g'
This will replace every instance of the string OLD with the string new in the file path/to/file. Be careful: this will replace EVERY instance of OLD. If OLD matches things you don't want, they will be replaced as well.
This construction is actually "regular expressions", so if you want to get fancy you can match against more complicated strings. But just be careful.
If you leave out the "-i" the string-replaced text will go to stdout, instead of being replaced in the file "in place", so you can check it first.
query replace in emacs
If you want more fine-grained control of text replace, so that you can see what's being replaced, try using "query-replace" in emacs:
M-x query-replace
You can then type in the original string, followed by the replacement string. When it starts to run it will highlight the string that will be replaced. Hit "space" to accept or "n" to skip and go to the next.
|
13221
|
Wed Aug 16 20:01:03 2017 |
gautam | Update | General | SUS model ASC input weirdness |
I'm not sure if this has something to do with the model restarts / new RCG, but while I was re-enabling the MC watchdogs, I noticed the RMS sensor voltage channels on ITMX hovering around ~100mV, even though local damping was on (in which configuration I would expect <1mV if everything is working normally). I was confused by this behaviour, and after staring at the ITMX suspension screen for a while, I noticed that the input to the "ASCP" and "ASCY" servos were "-nan", and the outputs were 10^20 cts (see Attachment #1).
Digging a little deeper, I found that the same problem existed on ITMY, ETMX, ETMY, PRM (but not BS or SRM) - reasons unknown for now.
I have to check where this signal is coming from, but for now I just turned the "ASC Input" switch off. More investigation to be done, but in the meantime, ASS dither alignment may not be possible.
After consulting with Jamie, I have just disabled all outputs to the suspensions other than local damping loop outputs. I need to figure out how to get this configuration into the safe.snap file such that until we are sure of what is going on, the models start up in this safer configuration.
gedit 28 Oct 0026: Seems like this problem is seen at the sites as well. I wonder if the problem is related. |
Attachment 1: ITMX_ASC.png
|
|
13228
|
Fri Aug 18 21:58:35 2017 |
gautam | Update | General | SUS model ASC input weirdness |
I spent some time today trying to debug this issue.
Jamie and I had opened up the c1sus frontend to try and replace the RFM card before we realized that the problem was in the RCG code generator. During this process, we had disconnected all of the back-panel cabling to this machine (2 ethernet cables, dolphin cable, and RFM cables/fibers). I thought I may have accidentally returned the cables to the wrong positions - but all the status indicator lights indicate that everything is working as it should, and I also confirmed that the cabling is as it is in the pictures of the rack on the wiki page.
Looking at the SimuLink model diagram (see Attachment #1 for example), it looks like (at least some of) these channels are actually on the dolphin network, and not the RFM network (with which we were experiencing problems). This suggests that the problem is something deeper. Although I did see nans in some of the ETMX ASC channels as well, for which the channels are piped over the RFM network. Even more puzzling is that the ASC MEDM screen (Attachment #3) and the SimuLink diagram (Attachment #2) suggest that there is an output matrix in between the input signals and the output angular control signals to the suspensions. As Attachment #4 shows, the rows corresponding to ITMX PIT and YAW are zero (I confirmed using z read <matrixElement> ). Attachment #3 shows that the output of all the servo banks except CARM_YAW is zero, but CARM_YAW has no matrix element going to the ITMs (also confirmed with z read <servoOutputChannel> ). So 0 x 0 should be 0, but for some reason the model doesn't give this output?
GV Edit: As EricQ just pointed out to me, nan x 0 is still nan, which probably explains the whole issue. Poking a little further, it seems like this is an SDF issue - the SDF table isn't able to catch differences for this hold output channel.
As I was writing this elog, I noticed that, as mentioned above, the CARM_YAW output was "nan". When I restart the model (thankfully this didn't crash c1lsc!), it seems to default to this state. Opening up the filter module, I saw that the "hold output" was enabled.
Toggling that switch made the nans in all the SUS ASC channels disappear. Mysterious .
All the points above stand - CARM_YAW output shouldn't have been going anywhere as per the output matrix, but it seems to have been responsible? Seems like a bug in any case if a model restarts with a field as "nan".
Anyways the problem seems to have been resolved so I'm going to try locking and dither aligning the arms now.
Rolf mentioned that a simple update could fix several of the CDS issues we are facing (e.g. inability to open up testpoints), but he didn't seem to have any insight into this particular issue. Jamie will try and recompile all the models and then we have to see if that fixes the remaining problems.
Quote: |
I have to check where this signal is coming from, but for now I just turned the "ASC Input" switch off. More investigation to be done, but in the meantime, ASS dither alignment may not be possible.
After consulting with Jamie, I have just disabled all outputs to the suspensions other than local damping loop outputs. I need to figure out how to get this configuration into the safe.snap file such that until we are sure of what is going on, the models start up in this safer configuration.
|
|
Attachment 1: ITMXP.png
|
|
Attachment 2: ASC_model_outmatrix.png
|
|
Attachment 3: ASC_medm.png
|
|
Attachment 4: ASC_outMat.png
|
|
4967
|
Thu Jul 14 15:27:08 2011 |
steve, | Update | SUS | SUS oplev spectras |
Quote: |
Quote: |
I repeated the BS oplev spectrum today and I do not understand why it does look different. I did it as Kiwamu describes it in entry#4948 The oplev servo was left ON!
|
It is working today! Finally I repeated the BS spectra, that we did with Kiwamu last week
|
The optical levers were centered during these measurements without the reference of locked cavities. They have no reference value now.
SRM sus need some help. ITMX is showing pitch/yaw modes of the pendulum .....OSEM damping is weak? |
Attachment 1: BS_oplev.jpg
|
|
Attachment 2: PRM_oplev.jpg
|
|
Attachment 3: ITMX_oplev.jpg
|
|
Attachment 4: ETMX_oplev.jpg
|
|
Attachment 5: ETMY_oplev.jpg
|
|
Attachment 6: SRM_oplev.jpg
|
|
Attachment 7: ITMY_oplev_b.jpg
|
|
4972
|
Fri Jul 15 09:25:02 2011 |
rana | Update | SUS | SUS oplev spectras |
In addition to the OL quadrants, you need to plot the OPLEV_PERROR and OPLEV_YERROR signals since these are the real signals we use for finding the mirror motion. If they're not in the Dataviewer, Jamie should add them as 256 Hz DAQ channels (using these names so that we have the continuity with the past). These DAQ channels correspond to the IN1 channels for the OL filter banks.
Also JPG are banned from the elog - you should put all of the plots into a single, multipage PDF file in honor of the new Wagonga. |
16553
|
Thu Jan 6 22:18:47 2022 |
Koji | Update | CDS | SUS screen debugging |
Indicated by the red arrow:
Even when the side damping servo is off, the number appears at the input of the output matrix
Indicated by the green arrows:
The face magnets and the side magnets use different ADCs. How about opening a custom ADC panel that accommodates all ADCs at once? Same for the DAC.
Indicated by the blue arrows:
This button opens a custom FM window. When the pitch gain was modified with a ramping time, the pitch and yaw gain grows at the same time even though only the pitch gain was modified.
Indicated by the orange circle:
The numbers are not indicated here, but they are input-related numbers (for watchdogging) rather than output-related numbers. It is confusing to place them here. |
Attachment 1: Screen_Shot_2022-01-06_at_18.03.24.png
|
|
16570
|
Tue Jan 11 10:46:07 2022 |
Tega | Update | CDS | SUS screen debugging |
Seen. Thanks.
Red Arrow: The channel was labeled incorrectly as INMON instead of OUTPUT
Green Arrow: OK, I will create a custom medm screen for this.
Blue arrow: Hmm, OK I will look into this. Doing this work remotely is a pain as the medm response is quite slow for poking around.
Orange circle: OK, I'll move this to the left side of the line.
Note to self: I also noticed another error on the side (LPYS blue box just b4 the sum). The channel is pointing to YAW instead of the side, so needs to be fixed as well.
Quote: |
Indicated by the red arrow:
Even when the side damping servo is off, the number appears at the input of the output matrix
Indicated by the green arrows:
The face magnets and the side magnets use different ADCs. How about opening a custom ADC panel that accommodates all ADCs at once? Same for the DAC.
Indicated by the blue arrows:
This button opens a custom FM window. When the pitch gain was modified with a ramping time, the pitch and yaw gain grows at the same time even though only the pitch gain was modified.
Indicated by the orange circle:
The numbers are not indicated here, but they are input-related numbers (for watchdogging) rather than output-related numbers. It is confusing to place them here.
|
|
16611
|
Fri Jan 21 12:46:31 2022 |
Tega | Update | CDS | SUS screen debugging |
All done (almost)! I still have not sorted the issue of pitch and yaw gains growing together when modified using ramping time. Image of custom ADC and DAC panel is attached.
Quote: |
Seen. Thanks.
Quote: |
Indicated by the red arrow:
Even when the side damping servo is off, the number appears at the input of the output matrix
Indicated by the green arrows:
The face magnets and the side magnets use different ADCs. How about opening a custom ADC panel that accommodates all ADCs at once? Same for the DAC.
Indicated by the blue arrows:
This button opens a custom FM window. When the pitch gain was modified with a ramping time, the pitch and yaw gain grows at the same time even though only the pitch gain was modified.
Indicated by the orange circle:
The numbers are not indicated here, but they are input-related numbers (for watchdogging) rather than output-related numbers. It is confusing to place them here.
|
|
|
Attachment 1: Custom_ADC_DAC_monitors.png
|
|
16084
|
Sun Apr 25 21:21:02 2021 |
rana | Update | CDS | SUS simPlant model |
- I suggest not naming this the LSC model, since it has no LSC stuff.
- Also remove all the diagnostic stuff in the plant model. We need nothing except a generic filter Module, like in the SUS controller.
- Also, the TF looks kind of weird to me. I would like to see how you derive that eq.
- Connect the models and show us some plots of the behavior in physical units using FOTON to make the filters and diaggui/DTT (at first) to make the plots.
|
16088
|
Tue Apr 27 15:15:17 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
The first version of the single filter plant is below. Jon and I went through compiling a model and running it on the docker (see this post)
We activated an early version of the plant model (from about 10 years ago) but this model was not designed to run on its own so we had to ground lots of unconnected pieces. the model compiled and ran so we moved on to the x1sus_single_plant model that I prepared.
This model is shown in the first attachment wasn't made to be run alone because it is technically a locked library (see the lock in the bottom left). It is supposed to be referenced by another file: x1sup.mdl (see the second attachment). This works great in the Simulink framework. I add the x1sus_single_plant model to the path and Matlab automatically attaches the two. but the docker does not seem to be able to combine the two. Starting the cymac it gives these errors:
cymac | Can't find sus_single_plant.mdl; RCG_LIB_PATH=/opt/rtcds/userapps:/opt/rtcds/userapps/lib:/usr/share/advligorts/src/src/epics/simLink/:/usr/share/advligorts/src/src/epics/simLink/lib:/usr/share/advligorts/src/src/epics/simLink
cymac | make[1]: *** [Makefile:30: x1sup] Error 2
cymac | make: *** [Makefile:35: x1sup] Error 1
I have tried putting the x1sus_single_plant.mdl file everywhere as well as physically dragging the blocks that I need into the x1sup.mdl file but it always seems to throw an error. Basically, I want to combine them into one file that is not referencing anything other than the CDS library but I cant figure out how to combine them.
Okay but the next problem is the medm screen generation. When we had the original 2010 model running the sitemap did not include it. It included models that weren't even running before but not the model Jon and I had added. I think this is because the other models that were not running had medm screens made for them. I need to figure out how to generate those screens. I need to figure out how to use the tool Chris made to auto-generate medm screens from Simulink but I can't seem to figure it out. And honestly, it won't be much use to me until I can actually connect the plant block to its framework. One option is to just copy each piece over one by one. this will take forever but at this point, I am frustrated enough to try it. I'll try to give another update later tonight. |
Attachment 1: x1sus_single_plant.pdf
|
|
Attachment 2: x1sup.pdf
|
|
16096
|
Thu Apr 29 13:41:40 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
To add the required library: put the .mdl file that contains the library into the userapps/lib folder. That will allow it to compile correctly
I got these errors:
Module ‘mbuf’ symvers file could not be found.
Module ‘gpstime’ symvers file could not be found.
***ERROR: IPCx parameter file /opt/rtcds/zzz/c1/chans/ipc/c1.ipc not found
make[1]: *** [Makefile:30: c1sup] Error 2
make: *** [Makefile:35: c1sup] Error 1
I removed all IPC parts (as seen in Attachment 1) and that did the trick. IPC parts (Inter-Process Communication) were how this model was linked to the controller so I don't know how exactly how I can link them now.
I also went through the model and grounded all un-attached inputs and outputs. Now the model compiles
Also, The computer seems to be running very slowly in the past 24 hours. I know Jon was working on it so I'm wondering if that had any impact. I think it has to do with the connection speed because I am connected through X2goclient. And one thing that has probably been said before but I want to note again is that you don't need a campus VPN to access the docker. |
Attachment 1: Non-IPC_Plant.pdf
|
|
16106
|
Fri Apr 30 12:52:14 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
Now that the model is finally compiled I need to make an medm screen for it and put it in the c1sim:/home/controls/docker-cymac/userapps/medm/ directory.
But before doing that I really want to test it using the autogenerated medm screens which are in the virtual cymac in the folder /opt/rtcds/tst/x1/medm/x1sup . In Jon's post he said that I can use the virtual path for sitemap after running $ eval $(./env_cymac) |
16109
|
Mon May 3 13:35:12 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
When the cymac is started it gives me a list of channels shown below.
$ Initialized TP interface node=8, host=98e93ecffcca
$ Creating X1:DAQ-DC0_X1IOP_STATUS
$ Creating X1:DAQ-DC0_X1IOP_CRC_CPS
$ Creating X1:DAQ-DC0_X1IOP_CRC_SUM
$ Creating X1:DAQ-DC0_X1SUP_STATUS
$ Creating X1:DAQ-DC0_X1SUP_CRC_CPS
$ Creating X1:DAQ-DC0_X1SUP_CRC_SUM
But when I enter it into the Diaggui I get an error:
The following channel could not be found:
X1:DAQ-DC0_X1SUP_CRC_CPS
My guess is that need to connect to the Diaggui to something that can access those channels. I also need to figure out what those channels are. |
16118
|
Tue May 4 14:55:38 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
After a helpful meeting with Jon, we realized that I have somehow corrupted the sitemap file. So I am going to use the code Chris wrote to regenerate it.
Also, I am going to connect the controller using the IPC parts. The error that I was having before had to do with the IPC parts not being connected properly. |
16122
|
Wed May 5 15:11:54 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
I added the IPC parts back to the plant model so that should be done now. It looks like this again here.
I can't seem to find the control model which should look like this. When I open sus_single_control.mdl , it just shows the C1_SUS_SINGLE_PLANT.mdl model. Which should not be the case. |
16124
|
Thu May 6 16:13:24 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
When using mdl2adl I was getting the error:
$ cd /home/controls/mdl2adl
$ ./mdl2adl x1sup.mdl
error: set $site and $ifo environment variables
to set these in the terminal use the following commands:
$ export site=tst
$ export ifo=x1
On most of the systems, there is a script that automatically runs when a terminal is opened that sets these but that hasn't been added here so you must run these commands every time you open the terminal when you are using mdl2adl. |